1
|
Alhamdan MM. Application of Laser Treatment in Adhesive Bonding of Liners to Polymethyl Methacrylate Denture Resins: A Systematic Review and Meta-Analysis. Photobiomodul Photomed Laser Surg 2023; 41:608-621. [PMID: 37910776 DOI: 10.1089/photob.2023.0066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2023] Open
Abstract
Objective: This systematic review and meta-analysis aimed to assess the influence of laser treatment on adhesive bonding of liners to polymethyl methacrylate (PMMA) denture base resins. Methods: The focused question was: "Does the application of laser treatment (Intervention) influence the adhesive bonding strength (Outcome) of liners to PMMA denture base resins (Population) as compared with untreated or unconditioned surfaces (Control)?" In vitro and clinical reports as well as reports on influence of laser treatments on bonding strength of liners to PMMA denture resins in comparison with untreated surfaces were included. Reports without any control group[s], without any application of laser[s] for PMMA denture bases that did not utilize PMMA denture bases, and not evaluate bond strength of PMMA denture base resins were excluded. An electronic search was conducted on PubMed, Scopus, and Web of Science. Meta-analyses were performed for calculating the standard mean difference (SMD) with a 95% confidence interval (95% CI). Results: Nine of the 12 included studies found that laser irradiation treatment produced significant surface texture alterations of the PMMA denture base and improved the adhesion between the PMMA denture base and soft lining. According to the meta-analysis, tensile bond strength showed an SMD of -2.49% (95% CI: -3.89 to -1.08; p = 0.0005), suggesting a statistically significant difference between the control and test groups (i.e., favoring laser-treated samples than untreated samples). Regarding shear bond strength scores, the outcomes showed an SMD of -2.24% (95% CI: -3.79 to -0.69; p = 0.005), suggesting a statistically significant difference between the control and test groups (i.e., favoring laser-treated samples than untreated samples). Conclusions: Despite the high heterogeneity among the included studies, it can be concluded that laser treatment might improve the bonding strengths of liners to PMMA denture base resins as compared with untreated surfaces. To validate the aforementioned conclusions, further verification is required through the implementation of well-designed randomized controlled trials with large sample sizes.
Collapse
Affiliation(s)
- Mai M Alhamdan
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
2
|
Hamedirad F, Alikhasi M, Hasanzade M. The Effect of Sandblasting on Bond Strength of Soft Liners to Denture Base Resins: A Systematic Review and Meta-Analysis of In Vitro Studies. Int J Dent 2021; 2021:5674155. [PMID: 34976062 PMCID: PMC8716237 DOI: 10.1155/2021/5674155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 10/18/2021] [Accepted: 11/23/2021] [Indexed: 11/17/2022] Open
Abstract
OBJECTIVES This study aimed to evaluate the effect of sandblasting on the bond strength of denture base resin to soft liners. MATERIALS AND METHODS This report follows the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. PubMed, Embase, Cochrane, Scopus, and OpenGrey databases were searched for in vitro studies that compared sandblasting with no treatment in terms of the tensile, shear, and peel bond strength of resilient lining materials (acrylic-based or silicone-based) to polymethyl methacrylate denture base resin. Based on the outcome, the analysis was carried out in three groups of tensile, shear, and peel bond strength. Subgroup analysis was done for the effect of size of particles on sandblasting, blasting pressure, and type of soft liner whenever possible. Heterogeneity was evaluated among the studies, and meta-analysis was performed with random effect models (p < .05). RESULTS After screening, 16 articles met the inclusion criteria for meta-analyses. No treatment showed significantly higher tensile (p < 0.001) or peel (p=0.04) bond strength, although shear bond strength of sandblasted resin was significantly better (p=0.008). Results of subgroup analyses of particle size favored the control group in 50 µ Al2O3 particle size (p < 0.001). In analyses of blasting pressure, the control group had significantly better tensile bond strength than specimens with blasting pressure ≤1 bar (p < 0.001) while specimens with blasting pressure beyond 1 bar showed significantly more tensile strength than control group (p=0.03). In silicon-based liners, groups without any surface treatment had significantly higher tensile bond strength (p < 0.001). CONCLUSION According to the in vitro studies, sandblasting would not lead to significant increase in bond strength of soft liner to the denture base resin.
Collapse
Affiliation(s)
- Fahimeh Hamedirad
- Dental Materials Research Center, Health Research Institute, Babol University of Medical Sciences, Babol, Iran
| | - Marzieh Alikhasi
- Dental Research Center and Dental Implant Research Center, Dentistry Research Institute, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Mahya Hasanzade
- Dental Research Center, Dentistry Research Institute, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
3
|
Wemken G, Burkhardt F, Spies BC, Kleinvogel L, Adali U, Sterzenbach G, Beuer F, Wesemann C. Bond strength of conventional, subtractive, and additive manufactured denture bases to soft and hard relining materials. Dent Mater 2021; 37:928-938. [PMID: 33722400 DOI: 10.1016/j.dental.2021.02.018] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 02/17/2021] [Accepted: 02/24/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To investigate the tensile and flexural strength of poured, subtractive, and additive manufactured denture base methacrylates bonded to soft and hard relining materials after hydrothermal cycling and microwave irradiation. METHODS This study included a conventional (CB), subtractive (SB), and additive (AB) base material as well as a soft (SCR) and hard (HCR) chairside and one hard laboratory-side (HLR) relining material. Reference bodies of the base materials and bonded specimens to the relining materials were produced with a rectangular cross-section. The specimens were either pre-treated by water storage (50 h, 37 °C), hydrothermal cycling (5000 cycles, 5 °C and 55 °C, 30 s each), or microwave irradiation (6 cycles, 640 W, 3 min, wet). A tensile and four-point bending test were performed for a total of 504 specimens. Data were analysed using multivariate analysis of variance (MANOVA) with post-hoc Tukey tests (α = 0.05). RESULTS In comparison with the other reference groups SB showed marginally higher tensile and flexural strength (p < 0.047). Bond strength to SCR was affected neither by the base material nor by the pre-treatment (p > 0.085). HCR demonstrated twice the bond strength to AB compared with SB and CB (p ≤ 0.001). HLR showed the highest bond strength to CB (p ≤ 0.001). There was no difference between the specimens after hydrothermally cycling and microwave irradiation (p > 0.318). SIGNIFICANCE The bond strength of hard relining materials to subtractive and additive manufactured denture bases differ compared with conventional pouring.
Collapse
Affiliation(s)
- Gregor Wemken
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | - Felix Burkhardt
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | - Benedikt Christopher Spies
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany.
| | - Laura Kleinvogel
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | - Ufuk Adali
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité - Universitätsmedizin Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Assmanshauser Str. 4-6, 14197 Berlin, Germany
| | - Guido Sterzenbach
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité - Universitätsmedizin Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Assmanshauser Str. 4-6, 14197 Berlin, Germany
| | - Florian Beuer
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité - Universitätsmedizin Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Assmanshauser Str. 4-6, 14197 Berlin, Germany
| | - Christian Wesemann
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité - Universitätsmedizin Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Assmanshauser Str. 4-6, 14197 Berlin, Germany
| |
Collapse
|
4
|
Özdemir H, Özdoğan A. Bond Strength of Resilient Lining Materials to Denture Base Resin: A Systematic Review and Meta-Analysis. J Prosthodont 2018; 27:828-841. [DOI: 10.1111/jopr.12958] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/09/2018] [Indexed: 11/29/2022] Open
Affiliation(s)
- Hatice Özdemir
- Prosthodontics Department, Faculty of Dentistry; Atatürk University; Erzurum Turkey
| | - Alper Özdoğan
- Prosthodontics Department, Faculty of Dentistry; Atatürk University; Erzurum Turkey
| |
Collapse
|
5
|
Popescu MC, Bita BI, Tucureanu V, Vasilache D, Banu MA, Avram AM, Giurescu-Dumitrescu RA. Superficial and Inner Examination of a Microwave-Irradiated Dental Acrylic Resin and Its Metal-Polymer Interface. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2018; 24:49-59. [PMID: 29485028 DOI: 10.1017/s1431927618000089] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The aim of this study is to conduct an extended surface and cross-section characterization of a denture base acrylic resin subjected to 500, 650, and 750 W microwave irradiation for 2, 3, and 5 min to assess its morphological modifications. A commercial heat-cured powder was polymerized according to the manufacturer's specifications and distributed into 20 circular samples. A stainless-steel wire was partially embedded in half of the discs, in order to investigate the metal-polymer interface. High-resolution scanning electron microscopy (SEM) imaging, white light interferometry, roughness measurements and Fourier transform infrared spectrometry were employed for morphological and structural evaluation of the irradiated polymer. Superficial adaptation was discovered after 5 min exposure at 500 W, 650 W, and 750 W, revealing significant roughness correction for 750 W. SEM characterization revealed the inner alteration of the resin for the 750 W protocol and a metal-polymer gap developed regardless of the irradiation conditions. The considerable temperature fluctuations that the samples were subject to during the experiments did not essentially change the poly(methyl-methacrylate) bond structure.
Collapse
Affiliation(s)
- Marian C Popescu
- 1Nano-Scale Structuring and Characterization Laboratory,National Institute for Research and Development in Microtechnologies,126A Erou Iancu Nicolae Street,077190 Bucharest,Romania
| | - Bogdan I Bita
- 1Nano-Scale Structuring and Characterization Laboratory,National Institute for Research and Development in Microtechnologies,126A Erou Iancu Nicolae Street,077190 Bucharest,Romania
| | - Vasilica Tucureanu
- 3Laboratory for Micro- and Nanofluidics,National Institute for Research and Development in Microtechnologies,126A Erou Iancu Nicolae Street,077190 Bucharest,Romania
| | - Dan Vasilache
- 5Microwave Circuits and Devices Laboratory,Micromachined Structures,National Institute for Research and Development in Microtechnologies,126A Erou Iancu Nicolae Street,077190 Bucharest,Romania
| | - Melania A Banu
- 6Laboratory of Nanobiotechnology,National Institute for Research and Development in Microtechnologies,126A Erou Iancu Nicolae Street,077190 Bucharest,Romania
| | - Andrei M Avram
- 3Laboratory for Micro- and Nanofluidics,National Institute for Research and Development in Microtechnologies,126A Erou Iancu Nicolae Street,077190 Bucharest,Romania
| | - Raluca A Giurescu-Dumitrescu
- 8Disciplines of Dental Medicine Department, Faculty of Dental Medicine,Titu Maiorescu University,67A Gheorghe Petrascu Street,031593 Bucharest,Romania
| |
Collapse
|
6
|
Ekren O, Ozkomur A. Influence of ozone and paracetic acid disinfection on adhesion of resilient liners to acrylic resin. J Adv Prosthodont 2016; 8:290-5. [PMID: 27555898 PMCID: PMC4993842 DOI: 10.4047/jap.2016.8.4.290] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2015] [Revised: 04/11/2016] [Accepted: 05/30/2016] [Indexed: 11/28/2022] Open
Abstract
PURPOSE The aim of this study was to evaluate the effect of paracetic acid (PAA) and ozone disinfection on the tensile bond strength (TBS) of silicone-based resilient liners to acrylic resins. MATERIALS AND METHODS One hundred and twenty dumbbell shaped heat-polymerized acrylic resins were prepared. From the mid segment of the specimens, 3 mm of acrylic were grinded off and separated parts were reattached by resilient liners. The specimens were divided into 2 control (control1, control7) and 4 test groups of PAA and ozone disinfection (PAA1, PAA7, ozone1 and ozone7; n=10). While control groups were immersed in distilled water for 10 min (control1) and 7 days (control7), test groups were subjected to PAA (16 g/L) or ozone rich water (4 mg/L) for 1 cycle (10 min for PAA and 60 min for ozone) per day for 7 days prior to tensile tests. Measurements of the TBS were analyzed using 3-way ANOVA and Tukey's HSD test. RESULTS Adhesive strength of Mollosil decreased significantly by application of ozone disinfection. PAA disinfection had no negative effect on the TBS values of Mollosil and Molloplast B to acrylic resin. Single application of ozone disinfection did not have any negative effect on TBS values of Molloplast B, but prolonged exposure to ozone decreased its adhesive strength. CONCLUSION The adhesion of resilient liners to acrylic was not adversely affected by PAA disinfection. Immersion in ozonated water significantly decreased TBS of Mollosil. Prolonged exposure to ozone negatively affects adhesion of Molloplast B to denture base materials.
Collapse
Affiliation(s)
- Orhun Ekren
- Department of Prosthodontics, Faculty of Dentistry, Cukurova University, Adana, Turkey
| | - Ahmet Ozkomur
- Department of Prosthodontics, Faculty of Dentistry, Cukurova University, Adana, Turkey
| |
Collapse
|
7
|
Sánchez-Aliaga A, Pellissari CVG, Arrais CAG, Michél MD, Neppelenbroek KH, Urban VM. Peel bond strength of soft lining materials with antifungal to a denture base acrylic resin. Dent Mater J 2016; 35:194-203. [PMID: 27041008 DOI: 10.4012/dmj.2014-269] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The effect of the addition of nystatin, miconazole, ketoconazole, chlorhexidine, and itraconazole into the soft lining materials Softone and Trusoft on their peel bond strength to a denture base acrylic resin was evaluated. Specimens of soft lining materials (n=7) were made without (control) or with the incorporation of antifungals at their minimum inhibitory concentrations to the biofilm of C. albicans and bonded to the acrylic resin. Peel testing was performed after immersion in distilled water at 37ºC for 24 h, 7 and 14 days. Data (MPa) were analyzed by 3-way ANOVA/Tukey-Kramer test (α=0.05) and the failure modes were classified. The addition of nystatin and ketoconazole did not affect the peel bond strength for up to 14 days. Most failures were predominantly cohesive within soft lining materials. With the exception of itraconazole, incorporating the antifungals into the soft lining materials did not result in values below those recommended for peel bond strength after 7 and 14 days of analysis.
Collapse
|
8
|
Nakhaei M, Dashti H, Ahrari F, Vasigh S, Mushtaq S, Shetty RM. Effect of Different Surface Treatments and Thermocycling on Bond Strength of a Silicone-based Denture Liner to a Denture Base Resin. J Contemp Dent Pract 2016; 17:154-159. [PMID: 27207005 DOI: 10.5005/jp-journals-10024-1819] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
AIM The aim of this study is to evaluate the effects of three different surface treatments and thermocycling on the tensile strength of a silicone lining material to denture resin. MATERIALS AND METHODS A total of 96 cube-shaped specimens were fabricated using heat-cured polymethyl methacrylate (PMMA) denture base resin. Three millimeters of the material was cut from the midsection. The specimens were divided into four groups. The bonding surfaces of the specimens in each group received one of the following surface treatments: no surface treatment (control group), airborne particle abrasion with 110 pirn alumina particles (air abrasion group), Er:yttrium aluminum garnet laser irradiation (laser group), and air abrasion + laser. After the lining materials were processed between the two PMMA blocks, each group was divided into two subgroups (n = 12), either stored in distilled water at 37°C for 24 hours or thermocycled between 5 and 55°C for 5,000 cycles. The specimens were tested in tensile and shear strength in a universal testing machine. Data were analyzed with two-way analysis of variance and Tamhane's post hoc tests (α = 0.05). The mode of failure was determined, and one specimen in each group was examined by scanning electron microscopy. RESULTS Surface-treated groups demonstrated significantly higher tensile strengths compared to the control group (p < 0.001). Nonetheless, no significant differences were found between surface-treated groups (p > 0.05). The tensile strength was significantly different between thermocycled and water-stored specimens (p = 0.021). CONCLUSION Altering the surface of the acrylic denture base resin with air abrasion, laser, and air abrasion + laser increased the tensile strength. Thermocycling resulted in decrease in bond strength of silicone-based liner to surface-treated acrylic resin. CLINICAL SIGNIFICANCE Pretreatment of denture base resins before applying the soft liner materials improves the bond strength. However, thermocycling results in decrease in bond strength of soft denture liner to surface-treated acrylic resin.
Collapse
Affiliation(s)
- Mohammadreza Nakhaei
- Assistant Professor, Faculty of Dentistry and Dental Research Center, Dental Material Research Center, Mashhad University of Medical Sciences, Mashhad, Islamic Republic of Iran, Phone: +985138829501, e-mail:
| | - Hossein Dashti
- Department of Prosthodontics, Faculty of Dentistry and Dental Research Center, Mashhad University of Medical Sciences Mashhad, Islamic Republic of Iran
| | - Farzaneh Ahrari
- Department of Orthodontics, Faculty of Dentistry and Dental Research Center, Mashhad University of Medical Sciences Mashhad, Islamic Republic of Iran
| | | | - Shazia Mushtaq
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, Riyadh, Kingdom of Saudi Arabia
| | - Rohit Mohan Shetty
- Department of Prosthodontics, KLE Society's Institute of Dental Sciences, Bengaluru, Karnataka, India
| |
Collapse
|
9
|
Ogawa A, Kimoto S, Saeki H, Ono M, Furuse N, Kawai Y. The influence of patient characteristics on acrylic-based resilient denture liners embedded in maxillary complete dentures. J Prosthodont Res 2016; 60:199-205. [PMID: 26778580 DOI: 10.1016/j.jpor.2015.12.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2015] [Revised: 12/01/2015] [Accepted: 12/03/2015] [Indexed: 10/22/2022]
Abstract
PURPOSE A major complication associated with the use of resilient denture liners (RDLs) is a change in hardness over time. In vivo studies on the deterioration of RDLs over time are needed. We aimed to investigate the influence of patient characteristics on the hardness of acrylic-based RDLs (ARDLs) embedded in complete maxillary dentures. We hypothesized that 1 month after application of the ARDLs, the hardness would be influenced by age, saliva condition, occlusal force, smoking, drinking, denture wearing during sleeping, denture cleanser usage, and denture type. METHODS Thirty complete maxillary denture wearers were recruited after obtaining informed consent. One investigator measured the Shore D hardness of the commercially available ARDLs, Soften (SFT), FD Soft (FDS), and Bio Liner (BIO) using a Vesmeter(®). The salivary flow rates and pH values and the occlusal force were measured for all patients before initiation of the study. T-tests and Pearson's correlation coefficients were used for the statistical analyses. A p-value of <0.05 was considered statistically significant. RESULTS Smoking, wearing dentures while sleeping, use of denture cleansers, and denture type were associated with an increase in the hardness of the RDLs. The resting saliva pH only influenced the hardness of the SFT ARDLs. CONCLUSIONS Smoking, denture wearing while sleeping, denture cleanser usage, denture type, and resting saliva pH are important predictors of the deterioration of ARDLs over time.
Collapse
Affiliation(s)
- Akina Ogawa
- Nihon University Graduate School of Dentistry at Matsudo, Removable Prosthodontics, Matsudo, Japan
| | - Suguru Kimoto
- Department of Removable Prosthodontics, Nihon University School of Dentistry at Matsudo, Matsudo, Japan.
| | - Hiroyuki Saeki
- Department of Removable Prosthodontics, Nihon University School of Dentistry at Matsudo, Matsudo, Japan
| | - Masanori Ono
- Nihon University Graduate School of Dentistry at Matsudo, Removable Prosthodontics, Matsudo, Japan
| | - Nobuhiko Furuse
- Nihon University Graduate School of Dentistry at Matsudo, Removable Prosthodontics, Matsudo, Japan
| | - Yasuhiko Kawai
- Department of Removable Prosthodontics, Nihon University School of Dentistry at Matsudo, Matsudo, Japan
| |
Collapse
|
10
|
Tugut F, Coskun ME, Dogan DO, Kirmali O, Akin H. Tensile Bond Strength between Soft Liners and Two Chemically Different Denture Base Materials: Effect of Thermocycling. J Prosthodont 2015; 25:319-23. [DOI: 10.1111/jopr.12296] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/15/2014] [Indexed: 11/29/2022] Open
Affiliation(s)
- Faik Tugut
- Department of Prosthodontics, Faculty of Dentistry; Cumhuriyet University; Sivas Turkey
| | - Mehmet Emre Coskun
- Department of Prosthodontics, Faculty of Dentistry; Cumhuriyet University; Sivas Turkey
| | - Derya Ozdemir Dogan
- Department of Prosthodontics, Faculty of Dentistry; Cumhuriyet University; Sivas Turkey
| | - Omer Kirmali
- Department of Prosthodontics, Faculty of Dentistry; Akdeniz University; Antalya Turkey
| | - Hakan Akin
- Department of Prosthodontics, Faculty of Dentistry; Cumhuriyet University; Sivas Turkey
| |
Collapse
|
11
|
Klironomos T, Katsimpali A, Polyzois G. The Effect of Microwave Disinfection on Denture Base Polymers, Liners and Teeth: A Basic Overview. Acta Stomatol Croat 2015; 49:242-53. [PMID: 27688409 PMCID: PMC4993596 DOI: 10.15644/asc49/3/7] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2015] [Accepted: 06/29/2015] [Indexed: 10/31/2022] Open
Abstract
The aim of this paper was to overview the current scientific knowledge concerning the effect of microwave disinfection on denture related material properties. Cross-infection control in dentistry is a significant issue in everyday clinical practice due to the recent increase in some infectious diseases such as hepatitis B, C and AIDS and therefore numerous methods of disinfection have been used. The most widespread method of disinfection used in everyday practice is chemical, however, studies have suggested that chemical disinfectants alter the physical and mechanical properties of the acrylic resins and enable the growth and proliferation of certain bacteria. Therefore, microwaves were introduced as an easy to use-and-access, low cost, chemical free alternative. The question that arose was if and in what way the microwave irradiation affected the denture related material properties. Microwaving affects the denture resin bases, liners and teeth in different ways. The results showed that microwave disinfection could be a safe alternative for the disinfection of denture bases and liners compared to the chemical one, when the procedure is carried out in dry conditions, but could possibly cause dimensional changes of clinical significance on them when the irradiation takes place in wet environment. It also seems to have no detrimental effects of clinical importance on the flexural properties, impact strength and hardness of denture resins and the bond, flexural strength, porosity and hardness of denture liners. The effects of microwave disinfection on the hardness of denture teeth and teeth/denture bond strength are still controversial and no safe conclusions can be drawn.
Collapse
Affiliation(s)
| | | | - Gregory Polyzois
- Professor, Department of Removable Prosthodontics, Dental School, University of Athens, Athens, Greece
| |
Collapse
|
12
|
Chladek G, Żmudzki J, Kasperski J. Long-Term Soft Denture Lining Materials. MATERIALS 2014; 7:5816-5842. [PMID: 28788163 PMCID: PMC5456172 DOI: 10.3390/ma7085816] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/13/2014] [Revised: 07/31/2014] [Accepted: 08/01/2014] [Indexed: 11/16/2022]
Abstract
Long-term soft denture lining (LTSDL) materials are used to alleviate the trauma associated with wearing complete dentures. Despite their established clinical efficacy, the use of LTSDLs has been limited due to the unfavorable effects of the oral environment on some of their mechanical and performance characteristics. The unresolved issue of LTSDL colonization by Candida albicans is particularly problematic. Silicone-based LTSDL (SLTSDL) materials, which are characterized by more stable hardness, sorption and solubility than acrylic-based LTSDLs (ALTSDLs), are currently the most commonly used LTSDLs. However, SLTSDLs are more prone to debonding from the denture base. Moreover, due to their limitations, the available methods for determining bond strength do not fully reflect the actual stability of these materials under clinical conditions. SLTSDL materials exhibit favorable viscoelastic properties compared with ALTSDLs. Furthermore, all of the lining materials exhibit an aging solution-specific tendency toward discoloration, and the available cleansers are not fully effective and can alter the mechanical properties of LTSDLs. Future studies are needed to improve the microbiological resistance of LTSDLs, as well as some of their performance characteristics.
Collapse
Affiliation(s)
- Grzegorz Chladek
- Faculty of Mechanical Engineering, Institute of Engineering Materials and Biomaterials, Silesian University of Technology, ul. Konarskiego 18a, Gliwice 44-100, Poland.
| | - Jarosław Żmudzki
- Faculty of Mechanical Engineering, Institute of Engineering Materials and Biomaterials, Silesian University of Technology, ul. Konarskiego 18a, Gliwice 44-100, Poland.
| | - Jacek Kasperski
- Department of Prosthetic Dentistry, Medical University of Silesia, pl. Akademicki 17, Bytom 41-902, Poland.
| |
Collapse
|
13
|
Akin H, Tugut F, Mutaf B, Guney U. Investigation of bonding properties of denture bases to silicone-based soft denture liner immersed in isobutyl methacrylate and 2-hydroxyethyl methacrylate. J Adv Prosthodont 2014; 6:121-5. [PMID: 24843397 PMCID: PMC4024556 DOI: 10.4047/jap.2014.6.2.121] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2013] [Revised: 02/03/2014] [Accepted: 03/04/2014] [Indexed: 11/22/2022] Open
Abstract
PURPOSE The purpose of this study was to investigate the bonding properties of denture bases to silicone-based soft denture liners immersed in isobutyl methacrylate (iBMA) and 2-hydroxyethyl methacrylate (HEMA) for various lengths of time. MATERIALS AND METHODS Polymethyl methacrylate (PMMA) test specimens were fabricated (75 mm in length, 12 mm in diameter at the thickest section, and 7 mm at the thinnest section) and then randomly assigned to five groups (n=15); untreated (Group 1), resilient liner immersed in iBMA for 1 minute (Group 2), resilient liner immersed in iBMA for 3 minutes (Group 3), resilient liner immersed in HEMA for 1 minute (Group 4), and resilient liner immersed in HEMA for 3 minutes (Group 5). The resilient liner specimens were processed between 2 PMMA blocks. Bonding strength of the liners to PMMA was compared by tensile test with a universal testing machine at a crosshead speed of 5 mm/min. Data were evaluated by 1-way ANOVA and post hoc Tukey-Kramer multiple comparisons tests (α=0.05). RESULTS The highest mean value of force was observed in Group 3 specimens. The differences between groups were statistically significant (P<.05), except between Group 1 and Group 4 (P=.063). CONCLUSION Immersion of silicone-based soft denture liners in iBMA for 3 minutes doubled the tensile bond strength between the silicone soft liner and PMMA denture base materials compared to the control group.
Collapse
Affiliation(s)
- Hakan Akin
- Department of Prosthodontics, Faculty of Dentistry, Cumhuriyet University, Sivas, Turkey
| | - Faik Tugut
- Department of Prosthodontics, Faculty of Dentistry, Cumhuriyet University, Sivas, Turkey
| | - Burcu Mutaf
- Department of Prosthodontics, Faculty of Dentistry, Cumhuriyet University, Sivas, Turkey
| | - Umit Guney
- Department of Prosthodontics, Faculty of Dentistry, Cumhuriyet University, Sivas, Turkey
| |
Collapse
|
14
|
Dynamic Mechanical Thermal Analysis of Maxillofacial Prosthetic Elastomers. J Craniofac Surg 2014; 25:e251-5. [DOI: 10.1097/scs.0000000000000556] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
|
15
|
Evaluation of effectiveness of microwave irradiation for disinfection of silicone elastomeric impression material. J Indian Prosthodont Soc 2014; 13:89-94. [PMID: 24431716 DOI: 10.1007/s13191-012-0230-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2012] [Accepted: 11/29/2012] [Indexed: 10/27/2022] Open
Abstract
Use of domestic microwave oven has been suggested as a method of disinfecting a number of dental materials used in dental practice. This study was done to analyse the effect of microwave irradiation on vinyl polysiloxane putty impression material (3M ESPE, Express™ STD) contaminated with test organisms (Staphylococcus aureus, Pseudomonas aeruginosa, Candida albicans. 180 square shaped specimens of addition silicon putty material were prepared and divided into 3 groups for three test organisms. The 3 groups were subdivided into 4 subgroups (n = 15) for different exposure parameters (control group 5, 6 and 7 min exposure at 650 W. The specimens were contaminated using standard inoculums of test organism and then were irradiated using domestic microwaves. Broth cultures of the control and test group specimens were plated on selective media culture plates. Colonies formed were counted. Data analyses included Kruskal-Walli's ANOVA and Mann-Whitney's tests. Nil values shows complete elimination of C. albicans and P. aeruginosa after 5, 6 and 7 min exposure. Staphylococcus aureus showed colonies with the mean value of 7.6 × 10(3) ± 2.3 × 10(3), 4.6 × 10(3) ± 2.6 × 10(3) after 5 and 6 min respectively and nil values after 7 min exposure. 5 min exposure caused complete elimination of C. albicans and P. aeruginosa strains, while 7 min exposure eliminated S. aureus completely.
Collapse
|
16
|
Eleni PN, Krokida MK, Polyzois GL, Gettleman L. Effect of different disinfecting procedures on the hardness and color stability of two maxillofacial elastomers over time. J Appl Oral Sci 2013; 21:278-83. [PMID: 23857654 PMCID: PMC3881904 DOI: 10.1590/1679-775720130112] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2013] [Accepted: 05/03/2013] [Indexed: 11/21/2022] Open
Abstract
OBJECTIVE Disinfection procedures often cause deterioration in a maxillofacial prosthesis. Color and hardness alterations could lead to a replacement of the prosthesis. MATERIAL AND METHODS An experimental chlorinated polyethylene (CPE) and a commercial polydimethyl siloxane (PDMS) sample were treated with four different disinfection procedures for a period which simulates 1 year of clinical service. The applied disinfection procedures included microwave exposure and immersion in three solutions, sodium hypochlorite, neutral soap and a commercial disinfecting soap. Shore A hardness (∆H) and color differences (∆E) were determined before and after each procedure. All data were analyzed by Two Way Analysis of Variance (ANOVA) and Tukey's post hoc tests at a level of α=0.05. RESULTS The samples presented significant alterations in color and hardness after the different disinfection treatments. The color differences (∆E) were at least eye detectable in all cases and clinically unacceptable in most of the cases, with values ranging from 1.51 to 4.15 and from 1.54 to 5.92 for the PDMS and CPE material, respectively. Hardness was decreased after all the disinfection procedures in the PDMS, while for the CPE, a decrement was observed after disinfection with sodium hypochlorite and neutral soap and an increment after microwave exposure and the disinfection with a commercial antimicrobial agent. The PDMS samples presented greater alterations in color and hardness after disinfection with sodium hypochlorite solution, while the microwave exposure caused negligible effects. The CPE samples were affected most after disinfection when treated with neutral soap, and more slightly when disinfected with sodium hypochlorite solution. CONCLUSIONS The disinfection procedures caused alterations in color and hardness of the examined materials. The most suitable disinfection procedure for the PDMS material is microwave exposure, while disinfection with sodium hypochlorite solution is not recommended. The CPE material is suggested to be disinfected with sodium hypochlorite solution and the use of neutral soap is not recommended. Comparing the two materials, the PDMS material is most color stable, while the CPE material presented fewer changes in hardness.
Collapse
Affiliation(s)
- Panagiota N Eleni
- Laboratory of Process Analysis and Design, Department of Chemical Engineering, National Technical University of Athens, Zografou Campus, Athens, Greece.
| | | | | | | |
Collapse
|
17
|
Eleni PN, Perivoliotis D, Dragatogiannis DA, Krokida MK, Polyzois GL, Charitidis CA, Ziomas I, Gettleman L. Tensile and microindentation properties of maxillofacial elastomers after different disinfecting procedures. J Mech Behav Biomed Mater 2013; 28:147-55. [DOI: 10.1016/j.jmbbm.2013.07.013] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2013] [Accepted: 07/12/2013] [Indexed: 10/26/2022]
|
18
|
Pahuja RK, Garg S, Bansal S, Dang RH. Effect of denture cleansers on surface hardness of resilient denture liners at various time intervals- an in vitro study. J Adv Prosthodont 2013; 5:270-7. [PMID: 24049568 PMCID: PMC3774941 DOI: 10.4047/jap.2013.5.3.270] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2013] [Revised: 07/08/2013] [Accepted: 07/10/2013] [Indexed: 12/26/2022] Open
Abstract
PURPOSE This study was aimed to determine the effect of two chemically distinct denture cleansers and water on the surface hardness of acrylic and silicone based soft denture liners at various time intervals. MATERIALS AND METHODS Two commonly used commercial resilient liner material were selected based on their chemical composition (silicone- and acrylic-based soft liners) for this investigation. 120 cylindrical specimens were made of 15 mm × 10 mm dimensions (according to ASTM: D-2240-64T) in a custom made metal mold. All specimens were stored in artificial saliva throughout the study. Forty specimens were cleansed daily in 0.5% sodium hypochlorite solution; forty were cleansed in sodium perborate and remaining forty specimens were daily rinsed in water. Testing was done at 1 week, 1 month, 3 months and 6 months for surface hardness using a Shore A Durometer. A mean of 3 reading for each sample was subjected to one-way ANOVA, Post Hoc test and pair-t test for statistical analysis. P values of less than 0.05 were taken as statistically significant. RESULTS Surface hardness of all the samples was significantly higher after a period of 6 months irrespective of the cleansing treatment. Minor changes were observed between control, sodium hypochlorite and sodium perborate groups with time. Greater change was observed in surface hardness of acrylic-based soft denture liners as compared to silicone-based soft liners for all groups, as time progressed. CONCLUSION Silicone-based soft denture liners performed significantly better in all cleansing treatments than acrylic-based soft denture liners.
Collapse
Affiliation(s)
- Rasleen Kaur Pahuja
- Department of Prosthodontics, Post Graduation Student, Maharishi Markandeshwar University, Mullana, Ambala, India
| | | | | | | |
Collapse
|
19
|
Korkmaz FM, Bagis B, Ozcan M, Durkan R, Turgut S, Ates SM. Peel strength of denture liner to PMMA and polyamide: laser versus air-abrasion. J Adv Prosthodont 2013; 5:287-95. [PMID: 24049570 PMCID: PMC3774943 DOI: 10.4047/jap.2013.5.3.287] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2013] [Revised: 07/05/2013] [Accepted: 07/10/2013] [Indexed: 11/08/2022] Open
Abstract
PURPOSE This study investigated the effect of laser parameters and air-abrasion on the peel strength of silicon-based soft denture liner to different denture resins. MATERIALS AND METHODS Specimens (N=180) were prepared out of three different denture base resins (Rodex, cross-linked denture base acrylic resin; Paladent, heat-cured acrylic resin; Deflex, Polyamide resin) (75 mm × 25 mm × 3 mm). A silicon-based soft denture liner (Molloplast B) was applied to the denture resins after the following conditioning methods: a) Air-abrasion (50 µm), b) Er,Cr:YSGG laser (Waterlase MD Turbo, Biolase Technology) at 2 W-20 Hz, c) Er,Cr:YSGG laser at 2 W-30 Hz, d) Er,Cr:YSGG laser at 3 W-20 Hz, e) Er,Cr:YSGG laser at 3 W-30 Hz. Non-conditioned group acted as the control group. Peel test was performed in a universal testing machine. Failure modes were evaluated visually. Data were analyzed using two-way ANOVA and Tukey's test (α=.05). RESULTS Denture liner tested showed increased peel strength after laser treatment with different parameters (3.9±0.4 - 5.58±0.6 MPa) compared to the control (3.64±0.5 - 4.58±0.5 MPa) and air-abraded groups (3.1±0.6 - 4.46±0.3 MPa), but the results were not statistically significant except for Paladent, with the pretreatment of Er,Cr:YSGG laser at 3 W-20 Hz. Polyamide resin after air-abrasion showed significantly lower peel strength than those of other groups (3.1±0.6 MPa). CONCLUSION Heat-cured acrylic resin, PMMA, may benefit from Er,Cr:YSGG laser treatment at 3 W-20 Hz irradiation. Air-abrasion of polyamide resins should be avoided not to impair their peel bond strengths to silicon-based soft denture liners.
Collapse
Affiliation(s)
- Fatih Mehmet Korkmaz
- Department of Prosthodontics, Faculty of Dentistry, Karadeniz Technical University, Trabzon, Turkey
| | | | | | | | | | | |
Collapse
|
20
|
Alcântara CS, Macêdo AFCD, Gurgel BCV, Jorge JH, Neppelenbroek KH, Urban VM. Peel bond strength of resilient liner modified by the addition of antimicrobial agents to denture base acrylic resin. J Appl Oral Sci 2013; 20:607-12. [PMID: 23329241 PMCID: PMC3881858 DOI: 10.1590/s1678-77572012000600004] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2010] [Accepted: 09/18/2011] [Indexed: 12/03/2022] Open
Abstract
In order to prolong the clinical longevity of resilient denture relining materials
and reduce plaque accumulation, incorporation of antimicrobial agents into these
materials has been proposed. However, this addition may affect their properties.
Collapse
Affiliation(s)
- Cristiane S Alcântara
- Faculty of Health and Life Sciences, Center of Superior Studies of Maceió, CESMAC, Maceió, AL, Brazil
| | | | | | | | | | | |
Collapse
|
21
|
Mantri SS, Parkhedkar RD, Mantri SP. Candida colonisation and the efficacy of chlorhexidine gluconate on soft silicone-lined dentures of diabetic and non-diabetic patients. Gerodontology 2012; 30:288-95. [PMID: 23137002 DOI: 10.1111/ger.12012] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/02/2012] [Indexed: 12/01/2022]
Abstract
OBJECTIVES The aim of this study was to evaluate Candida colonisation in the dentures with silicone soft liner in diabetic and non-diabetic patients and to assess the antifungal efficacy of chlorhexidine gluconate on Candida colonies. MATERIALS AND METHODS Thirty patients with resorbed ridges, fifteen each in the diabetic and non-diabetic group, were selected. The mandibular denture of each patient was lined with heat-polymerised silicone resilient liner. Patients were instructed to clean the dentures with soap water and brush. Samples from the fitting surface of mandibular dentures were collected at 15, 21 and 30 days. Subsequently, samples were collected at 15, 21 and 30 days, after cleaning the dentures with a detergent solution of 4% chlorhexidine gluconate, and incubated for the evaluation of Candida growth. These data were subjected to statistical analysis by Mann-Whitney U-test. RESULTS Normal oral flora in diabetics and non-diabetics showed no difference (p > 0.05). The density of colonies increased after 21 and 30 days in diabetic patients (p < 0.05). Number of Candida colonies significantly reduced in both the groups after 21 and 30 days of cleaning the dentures with 4% chlorhexidine gluconate (p < 0.05). CONCLUSION Dentures with silicone resilient liner exhibit increased Candida growth in diabetic patients. Four per cent chlorhexidine gluconate solution effectively disinfects these dentures.
Collapse
Affiliation(s)
- Sneha S Mantri
- Departmentt of Prosthodontics, Hitkarini Dental College & Hospital, Jabalpur, India
| | | | | |
Collapse
|
22
|
Anular delamination strength of human lumbar intervertebral disc. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2012; 21:1716-23. [PMID: 22547212 DOI: 10.1007/s00586-012-2308-x] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2011] [Revised: 02/20/2012] [Accepted: 04/08/2012] [Indexed: 10/28/2022]
Abstract
INTRODUCTION Progression of intervertebral disc (IVD) herniation does not occur exclusively in a linear manner through the anulus fibrosus (AF), but can migrate circumferentially due to localized AF delamination. Consequently, resistance to delamination is an important factor in determining risk of herniation progression. The inter-lamellar matrix located between the AF layers is responsible for resisting this delamination; however, its mechanical properties are largely unknown. This study aimed to determine the mechanical properties of the inter-lamellar matrix in human AF samples via a peel test. MATERIALS AND METHODS Seventeen human IVDs (degeneration grades of 2-3) were obtained from six lumbar spines. From these 17 discs, 53 tissue samples were obtained from the superficial and deep regions of the anterior and posterior AF. Samples were dissected into a 'T' configuration to facilitate a T-peel test (or 180-degree peel test) by initiating delamination between the two middle AF layers. RESULTS Peel strength was found to be 33 % higher in tissues obtained from the superficial AF region as compared with the deep region (p = 0.047). CONCLUSION This finding may indicate a higher resistance to delamination in the superficial AF, and as a result, delamination and herniation progression may occur more readily in the deeper layers of the AF.
Collapse
|
23
|
Tensile bond strength of silicone-based soft denture liner to two chemically different denture base resins after various surface treatments. Lasers Med Sci 2012; 28:119-23. [DOI: 10.1007/s10103-012-1082-7] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2011] [Accepted: 03/13/2012] [Indexed: 11/26/2022]
|
24
|
Effect of Immersion Cleansing in Color Stability and Hardness of Soft Denture Reliners. J Craniofac Surg 2012; 23:426-9. [DOI: 10.1097/scs.0b013e3182413bfa] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
25
|
Machado AL, Giampaolo ET, Vergani CE, Souza JFD, Jorge JH. Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation: surface roughness of denture base and reline materials. J Appl Oral Sci 2012; 19:521-8. [PMID: 21986658 PMCID: PMC3984201 DOI: 10.1590/s1678-77572011000500015] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2009] [Accepted: 05/25/2010] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVE The effect of disinfection by immersion in sodium perborate solution and microwave irradiation on surface roughness of one denture base resin (Lucitone 550 -L), 3 hard chairside reline resins (Tokuyama Rebase II-TR, New Truliner-NT, Ufi Gel hard-UH) and 3 resilient reline materials (Trusoft-T; Sofreliner-S, Dentusil-D) was evaluated. MATERIAL AND METHODS Thirty specimens of each material were made and divided into 3 groups: Control - not disinfected; P - daily disinfection by immersing in sodium perborate solution (3.8%); MW - microwave disinfection (6 min/650 W). Roughness measurements were made after polymerization (baseline) and after 1, 3 and 28 days. Roughness differences relative to the baseline readings were analyzed by Student's t-test (P=0.05). RESULTS At baseline, Trusoft showed the highest (P<0.001) mean surface roughness (3.54 µm), and its surface roughness was significantly reduced after 28 days of disinfection by immersion in sodium perborate (P=0.013). Roughness measurements of material Trusoft were not performed after microwave disinfection due to the severe alterations on the surface. In the 3 groups evaluated, changes in roughness were significant for materials Ufi Gel hard (from 0.11 to 0.26 µm; P<0.041) and New Truliner (0.19 to 0.76 µm; P<0.019). The roughness of materials Lucitone 550 (0.37 µm), Tokuyama Rebase II (0.37 µm), Sofreliner (0.49 µm) and Dentusil (0.38 µm) remained unaffected (P>0.05). CONCLUSIONS The roughness of the hard reline materials Ufi Gel hard and New Truliner was adversely affected by microwave disinfection, immersion in water or in sodium perborate. Microwave disinfection caused severe alterations on the surface of the resilient liner Trusoft.
Collapse
Affiliation(s)
- Ana Lucia Machado
- Department of Dental Materials and Prosthodontics, Araraquara Dental School, Univ. Estadual Paulista, Araraquara, SP, Brazil
| | | | | | | | | |
Collapse
|
26
|
Effect of different surface treatments on tensile bond strength of silicone-based soft denture liner. Lasers Med Sci 2011; 26:783-8. [DOI: 10.1007/s10103-010-0825-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2010] [Accepted: 08/03/2010] [Indexed: 10/19/2022]
|
27
|
Machado AL, Giampaolo ET, Pavarina AC, Jorge JH, Vergani CE. Surface roughness of denture base and reline materials after disinfection by immersion in chlorhexidine or microwave irradiation. Gerodontology 2011; 29:e375-82. [DOI: 10.1111/j.1741-2358.2011.00484.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
28
|
Strength of the bond between a silicone lining material and denture resin after Er:YAG laser treatments with different pulse durations and levels of energy. Lasers Med Sci 2010; 27:281-5. [DOI: 10.1007/s10103-010-0862-1] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2010] [Accepted: 10/28/2010] [Indexed: 10/18/2022]
|
29
|
Hatamleh MM, Maryan CJ, Silikas N, Watts DC. Effect of Net Fiber Reinforcement Surface Treatment on Soft Denture Liner Retention and Longevity. J Prosthodont 2010; 19:258-62. [DOI: 10.1111/j.1532-849x.2009.00566.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
30
|
Iwaki M, Akiba N, Minakuchi S, Takahashi H. Influence of methyl mercaptan at early setting stages on the properties of self curing addition silicone resilient denture lining materials. J Prosthodont Res 2009; 53:161-5. [PMID: 19589744 DOI: 10.1016/j.jpor.2009.05.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2009] [Revised: 03/16/2009] [Accepted: 05/07/2009] [Indexed: 11/29/2022]
Abstract
PURPOSE The aim of the present study was to clarify the influence of early setting conditions on the properties of self curing addition silicone resilient denture lining materials. METHODS Four auto-mix types of commercial self curing addition silicone resilient denture lining materials were used. Agar plates containing various concentrations of methyl mercaptan (MMP) were prepared and cylindrical specimens (10mm in height and 10mm in diameter) of silicone liners were set on the agar plate. The Shore A hardness of the agar-contacted surface of the specimen was measured at 0, 1, 7 and 28 days after stored in 37 degrees C water. The viscoelastic properties (instantaneous elastic modulus, coefficient of viscosity and permanent deformation) of two silicone liners, which showed a great decrease in the Shore A hardness by agar contact, were determined by a creep meter. RESULTS The Shore A hardness, coefficient of viscosity, and instantaneous elastic modulus deceased when the specimen was set on the MMP containing agar plate, but the permanent deformation of these specimens increased. CONCLUSION The exposure to MMP at the early setting stage influenced the properties of self curing addition silicone resilient denture lining materials.
Collapse
Affiliation(s)
- Maiko Iwaki
- Complete Denture Prosthodontics, Department of Masticatory Function Rehabilitation, Division of Oral Health Sciences, Graduate School, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyou- ku, Tokyo 113-8549, Japan
| | | | | | | |
Collapse
|
31
|
De Rezende Pinto L, Rodríguez Acosta EJT, Távora FFF, Da Silva PMB, Porto VC. Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins. Gerodontology 2009; 27:147-53. [DOI: 10.1111/j.1741-2358.2009.00282.x] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
32
|
Novais PMR, Giampaolo ET, Vergani CE, Machado AL, Pavarina AC, Jorge JH. The occurrence of porosity in reline acrylic resins. Effect of microwave disinfection. Gerodontology 2009; 26:65-71. [DOI: 10.1111/j.1741-2358.2008.00251.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
33
|
Tanimoto Y, Saeki H, Kimoto S, Nishiwaki T, Nishiyama N. Evaluation of adhesive properties of three resilient denture liners by the modified peel test method. Acta Biomater 2009; 5:764-9. [PMID: 18829404 DOI: 10.1016/j.actbio.2008.08.021] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2008] [Revised: 08/06/2008] [Accepted: 08/29/2008] [Indexed: 10/21/2022]
Abstract
The characteristics of adhesive properties between a denture base and resilient denture liner were investigated by a modified peel test with an L-shaped metal attachment. Three commercially resilient denture lining materials, namely GC Reline Soft (S), GC Reline Extra Soft (ES), and GC Reline Ultra Soft (US), were evaluated. Acrylic resin (GC Acron) was used as denture base material. Peel specimens consisting of the denture base acrylic resin and resilient denture liner were tested after storage for 1 and 30 days in distilled water at 37 degrees C. The modified peel test method gave load-displacement curves and work of adhesion (W(A)) values of the denture base material and resilient denture liner. The W(A) of specimens after 1 day of storage ranged from 1.71 to 2.55 N mm(-1) and increased in the order from US to S to ES. On the other hand, the W(A) of specimens after 30 day of storage ranged from 1.44 to 2.47 N mm(-1) and increased in the order from US to ES to S. US had significantly lower W(A) after 1 and 30 days of storage than did S and ES (P<0.05). Comparison of the W(A) between 1 and 30 days, reveals large differences for ES and US, but not for S. This could be explained by the difference in failure modes. Within the limitations of this investigation, it was concluded the modified peel test is effective for evaluating the adhesion between denture base material and a resilient denture liner.
Collapse
|