1
|
Oancea L, Cristache CM, Macris A. Impact of Substrate Material, Esthetic Material Thickness, and Cement on Color Reproduction in Implant-Supported Fixed Restorations. Cureus 2024; 16:e71227. [PMID: 39525194 PMCID: PMC11550146 DOI: 10.7759/cureus.71227] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/10/2024] [Indexed: 11/16/2024] Open
Abstract
Purpose This study aimed to evaluate the impact of substrate material, esthetic material type and thickness, and cement shade on the final color reproduction of implant-supported fixed restorations. The goal was to identify optimal combinations for achieving clinically acceptable esthetic outcomes. Material and methods An in vitro study was conducted using four substrate materials, hybrid polyetherketoneketone (PEEK)-based ceramic-reinforced polymer (BioHPP), chromium-cobalt alloy (CrCo), grade 5 titanium (Ti), and white zirconium oxide ceramic (WZirCAD), and three esthetic materials, lithium disilicate ceramic (e.max CAD), polymethyl methacrylate (PMMA), and zirconia oxide ceramic (e.max ZirCAD), at five different thicknesses (0.5, 1, 1.5, 2, and 2.5 mm). Color differences (ΔE*) were measured using a spectrophotometer, both with and without cement application. Statistical analysis was performed using the Kruskal-Wallis test and Bonferroni correction to assess the effects of material combinations on color reproduction. Results The study found that a 1 mm thickness of e.max CAD on BioHPP and CrCo substrates provided the best color matching, with ΔE* values closest to clinical acceptability. PMMA showed higher ΔE* values, indicating lower color stability compared to e.max CAD and e.max ZirCAD. Cement shade had a near-significant influence on final color perception, particularly with e.max ZirCAD on CrCo substrates. Conclusions The study suggests that using e.max CAD at 1 mm thickness on BioHPP or CrCo substrates provides superior esthetic results, underscoring the need for careful material selection in clinical practice. Further in vivo research is recommended to validate these findings and explore long-term outcomes.
Collapse
Affiliation(s)
- Luminita Oancea
- Prosthetic Dentistry, Carol Davila University of Medicine and Pharmacy, Bucharest, ROU
| | | | - Andrei Macris
- Prosthetic Dentistry, Carol Davila University of Medicine and Pharmacy, Bucharest, ROU
| |
Collapse
|
2
|
Ansarifard E, Taghva M, Mosaddad SA, Akhlaghian M. The impact of various substrates, ceramic shades, and brands on the ultimate color and masking capacity of highly translucent monolithic zirconia: an in vitro study. Odontology 2024:10.1007/s10266-024-00996-0. [PMID: 39222097 DOI: 10.1007/s10266-024-00996-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Accepted: 08/15/2024] [Indexed: 09/04/2024]
Abstract
This study aimed to examine the impact of substrates, ceramic shades, and brands on the color and masking ability of highly translucent monolithic zirconia (HTMZ) using CIELab and CIEΔE2000 metrics. A total of 156 1-mm thick HTMZ disks in shades A1, A2, and A3 were produced using Dental Direkt and Kerox zirconia brands. Four 3-mm thick substrates (nickel-chromium alloy, non-precious gold alloy (NPG), zirconia shade A2, and resin composite shade A2) were prepared. HTMZ disks were overlaid on these substrates, and color measurements were taken with a spectrophotometer. Color differences (ΔE) were analyzed using CIELab and CIEΔE2000 formulas. The influence of brand, shade, substrate, and their interactions on ΔE values was assessed with a General Linear Model (GLM) and LSD pairwise comparison test. Spearman's correlation test examined the relationship between CIELab and CIEΔE2000 values. Results indicated that ΔEab was significantly influenced by substrate type and shade, while ΔE2000 was also affected by the ceramic brand. Mean color differences across ceramic-substrate groups were within clinically acceptable and perceptible ranges (clinically perceptible: ∆Eab ≥ 1.3 and ∆E2000 ≥ 0.8; clinically acceptable: 0.8 < ∆E2000 ≤ 1.8 and 1.3 < ∆Eab ≤ 2.7), except for NPG, which had ΔE values exceeding the perceptible range (ΔE2000: 1.1 ± 0.11 to 1.8 ± 0.31; ΔEab: 1.61 ± 0.15 to 2.16 ± 0.36). A significant correlation (r = 0.974, P < 0.001) was found between ΔEab and ΔE2000. Various ceramic brands and shades led to notable ΔE variations, yet average color differences within all ceramic-substrate groups remained clinically acceptable. Both ΔEab and ΔE2000 were reliable methods with a strong correlation for measuring color differences.
Collapse
Affiliation(s)
- Elham Ansarifard
- Department of Prosthodontics, Biomaterials Research Center, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Masumeh Taghva
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Seyed Ali Mosaddad
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
- Department of Research Analytics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India.
- Student Research Committee, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
- Department of Conservative Dentistry and Bucofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain.
| | - Marzieh Akhlaghian
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
| |
Collapse
|
3
|
Kang CM, Peng TY, Wu YA, Hsieh CF, Chi MC, Wu HY, Lin ZC. Comparison of Optical Properties and Fracture Loads of Multilayer Monolithic Zirconia Crowns with Different Yttria Levels. J Funct Biomater 2024; 15:228. [PMID: 39194666 DOI: 10.3390/jfb15080228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2024] [Revised: 08/13/2024] [Accepted: 08/14/2024] [Indexed: 08/29/2024] Open
Abstract
Multilayer monolithic zirconia, which incorporates polychromatic layers that mimic natural tooth gradients, offers enhanced aesthetics and functionality while reducing debonding risks and improving fabrication efficiency. However, uncertainties remain regarding the fracture characteristics of multilayer monolithic zirconia crowns under occlusal loading, whether composed of uniform or combined yttria levels. The current study investigated how variations in yttria levels and thicknesses affected the optical properties and fracture loads of multilayer monolithic zirconia. Samples of multilayer monolithic zirconia in the Vita A1 shade were used, while employing 3Y (SZ) and 4Y + 5Y (AZ) yttria levels. The optical properties, including the color difference (ΔEWS) and translucency parameters (TP00), were measured using a digital colorimeter. The fracture loads were analyzed using a universal testing machine, and fractured surfaces were examined under a stereomicroscope. Statistical analyses assessed the impacts of the yttria levels and sample thicknesses on the optical properties. The ΔEWS values of SZ ranged 3.6 to 4.0, while for AZ, ΔEWS at 0.5 mm was 3.9 and <2.6 for other thicknesses. The TP00 values decreased with an increased thickness, with AZ generally exhibiting greater translucency than SZ. In the fracture load investigations, SZ (>1600 N) generally exceeded AZ (>1260 N), with fracture loads notably increasing with thickness, particularly for premolars (SZ > 3270 N, AZ > 2257 N). SZ predominantly exhibited partial and complete fractures, whereas AZ showed fewer non-fracture categorizations. Complete fractures began with dense, irregular cracks that extended outward to reveal smooth surfaces, while premolars subjected to higher loads exhibited concentric ripple-like structures. Partial fractures revealed radial textures indicative of areas of stress concentration. In summary, higher yttria levels were correlated with increased translucency, while variations in the fracture loads primarily stemmed from differences in the tooth position or thickness. Overall, multilayer monolithic zirconia incorporating combined yttria levels of 4Y + 5Y (AZ) offered high translucency, precise color matching, and substantial fracture resistance, rendering it highly suitable for aesthetic and functional dental applications.
Collapse
Affiliation(s)
- Chien-Ming Kang
- Huayi Dental Laboratory, Taipei 10491, Taiwan
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan
| | - Tzu-Yu Peng
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan
- Research Center of Digital Oral Science and Technology, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan
| | - Yan-An Wu
- School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan
| | - Chi-Fei Hsieh
- School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan
| | - Miao-Ching Chi
- Research Center of Digital Oral Science and Technology, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan
- Department of Respiratory Care, Chang Gung University of Science and Technology, Chiayi 61363, Taiwan
- Chronic Diseases and Health Promotion Research Center, Chang Gung University of Science and Technology, Chiayi 61363, Taiwan
| | - Hsuan-Yu Wu
- School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan
- Division of Integrated Health Sciences, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima 834-8553, Japan
| | - Zih-Chan Lin
- Research Center of Digital Oral Science and Technology, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan
- Department of Respiratory Care, Chang Gung University of Science and Technology, Chiayi 61363, Taiwan
- Chronic Diseases and Health Promotion Research Center, Chang Gung University of Science and Technology, Chiayi 61363, Taiwan
| |
Collapse
|
4
|
Kang CM, Hsu WC, Chen MS, Wu HY, Mine Y, Peng TY. Fracture characteristics and translucency of multilayer monolithic zirconia crowns of various thicknesses. J Dent 2024; 145:105023. [PMID: 38670331 DOI: 10.1016/j.jdent.2024.105023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 04/22/2024] [Accepted: 04/23/2024] [Indexed: 04/28/2024] Open
Abstract
OBJECTIVES Multilayer monolithic zirconia (M-Zr) crowns can be engineered to achieve gradational translucency and color intensity. However, this modification may compromise the mechanical strength, raising concerns regarding the ability of M-Zr crowns to withstand occlusal stresses. The effects of M-Zr crown thickness on translucency and ability to endure occlusal forces were investigated at different tooth positions (incisors, premolars, and molars). The objective was to determine the minimal thickness of M-Zr crowns used in tooth preparation to meet aesthetic and functional demands. METHODS M-Zr samples (Vita A1) with four thicknesses (0.5, 1.0, 1.5, and 2.0 mm) were prepared and subjected to translucency testing using a digital colorimeter by 3-third and 9-square division methods. Crown-shaped M-Zr samples with three thicknesses (1.0, 1.5, and 2.0 mm) and three tooth positions (incisor, premolar, and molar) were digitally designed, and 2.0 mm metal abutments were fabricated. The samples were bonded to the abutments; their fracture characteristics were evaluated using a universal testing machine, and their fracture surfaces examined using an optical microscope. Statistical analyses included the Shapiro-Wilk test, Pearson correlation, and one-way and two-way ANOVA with a post hoc Tukey HSD test (α = 0.05). RESULTS Color analysis results revealed a significant negative correlation between thickness and translucency (r < -0.96, P < 0.01), with the highest values in the incisal region. Cross-sectional profiles confirmed the uniform thickness and morphology of the digitally designed M-Zr crowns. The results of fracture strength analysis showed position-dependent variability, a strong positive correlation with thickness (r > 0.96, P < 0.01), and fracture strengths consistently exceeding 1200 N across all tooth positions. Fracture patterns indicated that thinner crowns at the incisors and molars were more prone to cracking, whereas those at the premolars demonstrated significantly higher strength (4872.51 N, P < 0.05), only with crack or even no fracture occurring at 2.0 mm. CONCLUSIONS Thickness significantly influenced both the translucency and fracture strength of M-Zr, with the tooth position playing an additional role, albeit to a lesser extent. Although thinner crowns exhibited lower strength at each tooth position, even at a thickness of 1.0 mm, fracture strength exceeding 1200 N was maintained, surpassing the typical occlusal forces. Thus, it can be asserted that M-Zr crowns with a minimum thickness of 1.0 mm can meet both aesthetic and functional requirements.
Collapse
Affiliation(s)
- Chien-Ming Kang
- Huayi Dental Laboratory, Taipei, Taiwan; School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Wen-Chieh Hsu
- School of Dentistry, College of Oral Medicine, Chung Shan Medical University, Taichung, Taiwan; Department of Oral Hygiene, Hsin Sheng Junior College of Medical Care and Management, Taoyuan, Taiwan; Research Center of Precision Biomedical Implants, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - May-Show Chen
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan; Division of Prosthodontics, Department of Dentistry, Taipei Medical University Hospital, Taipei, Taiwan
| | - Hsuan-Yu Wu
- School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Yuichi Mine
- Department of Medical Systems Engineering, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan; Project Research Center for Integrating Digital Dentistry, Hiroshima University, Hiroshima, Japan
| | - Tzu-Yu Peng
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan.
| |
Collapse
|
5
|
Ghoveizi R, Baghaei M, Tavakolizadeh S, Tabatabaian F. Color match of ultra-translucency multilayer zirconia restorations with different designs and backgrounds. J Prosthodont 2024; 33:382-388. [PMID: 37155925 DOI: 10.1111/jopr.13700] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Accepted: 05/03/2023] [Indexed: 05/10/2023] Open
Abstract
PURPOSE The purpose of this in vitro study was to assess the color match of ultra-translucency multilayer zirconia restorations with different designs and backgrounds. MATERIALS AND METHODS Thirty ultra-translucency multilayer zirconia crown specimens were made in VITA classical shade B2 for a prepared maxillary central incisor. The specimens were divided into three groups based on the restoration design: veneered zirconia with a trestle design (VZT), veneered zirconia with a dentin core design (VZD), and full-contour zirconia (FCZ). In the groups VZT and VZD, the zirconia specimens were layered with a feldspathic veneering ceramic. The specimens were seated on five different backgrounds: shade B2 composite resin, shade B2 zirconia, copper-colored metal alloy, silver-colored metal alloy, and the prepared central incisor. CIELab values of the labial middle sections of the crown specimens were measured with a spectrophotometer. Color differences between the specimens and a shade B2 VITA classical tab (as a control) were calculated from the ΔE* ab formula and compared with an acceptability threshold (ΔE* ab = 3.7) to be clinically explicated. RESULTS Mean ΔE* ab values ranged between 1.17 and 8.48. The restoration design, the background type, and their interaction affected the ΔE* ab (p < 0.001). The mean ΔE* ab values for VZT with all backgrounds and for VZD with the silver-colored metal background were greater than the threshold (p < 0.001), whereas the mean ΔE* ab values for VZD with the other backgrounds and FCZ with all backgrounds were less than the threshold (p = 1). CONCLUSIONS Restoration design and background type affected the color match of ultra-translucency multilayer zirconia restorations. VZT restorations on all backgrounds and VZD restorations on a silver-colored metal background showed color mismatches. However, VZD restorations on the other backgrounds and FCZ restorations on all backgrounds demonstrated color matches.
Collapse
Affiliation(s)
- Rahab Ghoveizi
- Department of Prosthodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Maryam Baghaei
- School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Sara Tavakolizadeh
- Department of Prosthodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Farhad Tabatabaian
- Faculty of Dentistry, The University of British Columbia, Vancouver, British Columbia, Canada
| |
Collapse
|
6
|
Pongtongkham P, Pleumsamran N, Suttiat K. Effect of CAD/CAM Position and Thickness of Ultra-Translucent Multilayered Zirconia on Color Aspects. Int J Dent 2023; 2023:5000800. [PMID: 37635898 PMCID: PMC10460285 DOI: 10.1155/2023/5000800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 07/20/2023] [Accepted: 07/27/2023] [Indexed: 08/29/2023] Open
Abstract
Background Ultra-translucent multilayered zirconia restorations fabricated using computer-aided design and computer-aided manufacturing (CAD/CAM) technology have recently gained popularity. Their esthetic appeal is crucially dependent on the color accuracy, influenced by prosthesis thickness and multilayer composition due to CAD/CAM milling positions. This study comprehensively investigated how these two factors impacted color accuracy, thereby enhancing our understanding of color outcomes. Materials and Methods One hundred monolithic multilayer zirconia specimens with 10 × 10 mm square shape were milled in four different positions and five different thicknesses (1.0, 1.5, 2.0, 2.5, and 3.0 mm). The specimens were placed on an A3 shade resin composite substrate, and CIELAB values (L ∗, a ∗, and b ∗) were measured using a spectrophotometer. Delta E (ΔE) values were calculated to quantify the color differences between the specimens and the A3 VITA classical shade tab and compared with the perceptibility and acceptability thresholds of ΔE = 1.2 and 2.7, respectively. Pearson correlation, two-way ANOVA, and Tukey multiple comparisons (α = 0.05) were performed. Results The proportion of the dentin layer was positively correlated with the a ∗ and b ∗ values, while specimen thickness was positively correlated with the a ∗ value and negatively correlated with the L ∗ and b ∗ values. Significant difference in ΔE value due to different CAD/CAM positions was not observed within the same specimen thickness. Perceptible color differences were observed in specimens with thicknesses greater than 1 mm, while specimens with 1 mm thickness fell within the clinically acceptable range. Highest ΔE value was found in the specimen with 1 mm thickness. Conclusions Different compositions of multilayers in the final restoration due to different CAD/CAM positions do not significantly affect the color appearance of ultra-translucent multilayer zirconia, with color only influenced by specimen thickness.
Collapse
Affiliation(s)
- Palanupap Pongtongkham
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Nathawat Pleumsamran
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Kullapop Suttiat
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand
| |
Collapse
|
7
|
Çeken A, Kılınç H, Turgut S. Effect of abutment types and resin cements on the esthetics of implant-supported restorations. J Adv Prosthodont 2023; 15:114-125. [PMID: 37441718 PMCID: PMC10333101 DOI: 10.4047/jap.2023.15.3.114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 05/31/2023] [Accepted: 06/20/2023] [Indexed: 07/15/2023] Open
Abstract
PURPOSE The aim of the study was to evaluate the optical properties of new generation (3Y-TZP) monolithic zirconia (MZ) with different abutment types and resin cement shades. MATERIALS AND METHODS A1/LT MZ specimens were prepared (10 × 12 × 1 mm, N = 30) and divided into 3 groups according to cement shades as transparent (Tr), yellow (Y) and opaque (O). Abutment specimens were obtained from 4 different materials including zirconia (Group Z), hybrid (Group H), titanium (Group T) and anodized yellow titanium (Group AT). MZ and abutment specimens were then cemented. L*, a*, and b* parameters were obtained from MZ, MZ + abutment, and MZ + abutment + cement. ΔE001* (between MZ and MZ + abutment), ΔE002* (between MZ and MZ + abutment + cement) and ΔE003* (between MZ + abutment and MZ + abutment + cement) values were calculated. Statistical analyses included 2-way ANOVA, Bonferroni, and Paired Sample t-Tests (P < .05). RESULTS Abutment types and resin cements had significant effect on L*, a*, b*, ΔE001*, ΔE002*, and ΔE003* values (P < .001). Without cementation, whereas zirconia abutment resulted in the least discoloration (ΔE001* = 0.68), titanium abutment caused the most discoloration (ΔE001* = 4.99). The least ΔE002* = 0.68 value was seen using zirconia abutment after cementation with yellow shaded cement. Opaque shaded cement caused the most color change (ΔE003* = 5.24). Cement application increased the L* values in all groups. CONCLUSION The least color change with/without cement was observed in crown configurations created with zirconia abutments. Zirconia and hybrid abutments produced significantly lower ΔE002* and ΔE003* values in combination with yellow shaded cement. The usage of opaque shaded cement in titanium/anodized titanium groups may enable the clinically unacceptable ΔE00* value to reach the acceptable level.
Collapse
Affiliation(s)
- Asena Çeken
- Çerkezköy Oral and Dental Health Care Center, Tekirdağ Provincial Health Directorate, Tekirdağ, Türkiye
| | - Hamiyet Kılınç
- Department of Prosthodontics, Faculty of Dentistry, On Dokuz Mayıs University, Samsun, Türkiye
| | - Sedanur Turgut
- Department of Prosthodontics, Faculty of Dentistry, Karadeniz Technical University, Trabzon, Türkiye
| |
Collapse
|
8
|
Lee WF, Takahashi H, Iwasaki N, Peng PW. Effect of thickness of externally characterized stains on optical properties of high-translucency zirconia. Clin Oral Investig 2023; 27:165-171. [PMID: 36125622 DOI: 10.1007/s00784-022-04704-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Accepted: 08/29/2022] [Indexed: 01/28/2023]
Abstract
OBJECTIVES There is insufficient information about the effects of the thickness of externally characterized stains or glazes on CIELAB color parameters and the translucency parameter (TP) of 5 mol% yttria partially stabilized zirconia (5Y-PSZ). The present study evaluated the effect of a thickness reduction of the externally characterized or glazed layer on its CIE2000 color parameters and TP00 of 5Y-PSZ. MATERIALS AND METHODS Twenty-eight specimens were sectioned from 5Y-PSZ blanks. Three brands of powdered stains (namely VI, SH, and IV) and a glaze (GL) were used to extrinsically stain the specimen surfaces (n = 7 per group). After measuring the final thickness and color, specimens of each group were carefully ground and finally polished. The reduced thickness was carefully controlled in decrements of 0.02 mm on the characterized stains or glazed layers at each reduction cycle until the surface of the un-stained zirconia was exposed. The CIELAB color parameters of specimens were measured using a spectrophotometer. Subsequently, differences in lightness (∆L'), chroma (∆C'), and hue (∆H'), and TP00 values and color differences (ΔE00) were calculated using the CIEDE2000 formula to determine differences between the specimen and the un-stained zirconia at each reduction cycle. A paired-samples t-test, two-way mixed-design analysis of variance, and Pearson correlation coefficient were used to analyze the data (α = 0.05). RESULTS There were no significant differences in lightness, chroma, hue, or TP00 values before or after glazing or after each reduction cycle of the glazed layer. Mean ΔE00 values ranged between 20.94 and 33.55 after applying the externally characterized stains. With a decreased thickness of the characterized stain layer, there were observed that significant decreases in ∆L', ∆H', ∆C', and ΔE00, and significant increases in TP00. CONCLUSIONS Increasing the thickness of externally characterized stains decreased the lightness and caused the alternation of chroma and hue, whereas these phenomena were not observed in the glazed group. There was a slight change of CIE2000 color parameters and TP00 when the thickness of the characterized layer exceeded 0.06 mm. CLINICAL RELEVANCE The application and thickness of externally characterized stains can sensitively affect CIE2000 color parameters and translucency of 5Y-PSZ.
Collapse
Affiliation(s)
- Wei-Fang Lee
- School of Dental Technology, Taipei Medical University, Taipei, 11031, Taiwan
| | - Hidekazu Takahashi
- School of Oral Health Engineering, Faculty of Dentistry, Tokyo Medical and Dental University, Tokyo, 113-8549, Japan
| | - Naohiko Iwasaki
- School of Oral Health Engineering, Faculty of Dentistry, Tokyo Medical and Dental University, Tokyo, 113-8549, Japan
| | - Pei-Wen Peng
- School of Dental Technology, Taipei Medical University, Taipei, 11031, Taiwan.
| |
Collapse
|
9
|
Bas BB, Cakan U. Evaluation of the effect of anodization-colored titanium abutments and zirconia substructure thickness on zirconia substructure color: An In vitro study. Niger J Clin Pract 2022; 25:2024-2029. [PMID: 36537461 DOI: 10.4103/njcp.njcp_484_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
BACKGROUND AND AIM The aim of this study is to evaluate the effect of anodized titanium abutments and zirconia substructure thickness on the color of zirconia substructure. MATERIALS AND METHODS In this study, an electrochemical anodization setup was prepared for titanium coloring. Commercial titanium, anodization-colored yellow and pink titanium, and zirconia were used as different abutment specimens. Thirty zirconia discs in 0.7, 0.9, and 1.1 mm thickness were prepared from zirconia blocks as zirconia substructure specimens (n = 10). Zirconia substructure specimens of different thicknesses were placed on abutment specimens of different colors and L*, a*, b* values were measured with a spectrophotometer device. Color difference (ΔE) was calculated according to the CIELab formula by comparing the L*, a*, and b* values obtained on the zirconia abutment with the L*, a*, and b* values obtained on the other abutments. Statistical analyzes were performed with two-way analysis of variance and Tukey Honestly Significant Difference (HSD)test (p < 0.05). RESULTS The increase in the thickness of the substructure resulted in a statistically significant difference on ΔE, L*, a*, and b* values (p < 0.001). The effect of abutment color had no significant effect on ΔE values. The highest ΔE value was 18.10 at zirconia substructure with 0.7 mm thickness when paired with pink-anodized titanium abutment specimens. CONCLUSION The thickness of zirconia substructure and the color of titanium abutments affect zirconia substructure color.
Collapse
Affiliation(s)
- B B Bas
- Department of Prosthodontics, Institute of Health Sciences, Istanbul Medipol University, Istanbul, Turkey
| | - U Cakan
- Department of Prosthodontics, Faculty of Dentistry, Istanbul Health and Technology University, Istanbul, Turkey
| |
Collapse
|
10
|
Elraggal A, Aboushelib M, Abdel Raheem IM, Afifi RR. Effect of surface treatments on biaxial flexural strength, fatigue resistance, and fracture toughness of high versus low translucency zirconia. BMC Oral Health 2022; 22:412. [PMID: 36123676 PMCID: PMC9487058 DOI: 10.1186/s12903-022-02431-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Accepted: 09/05/2022] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Mechanical surface treatments can deteriorate the mechanical properties of zirconia. This study evaluated and compared the biaxial flexural strength, fracture toughness, and fatigue resistance of high translucency (HT) to low translucency (LT) zirconia after various mechanical surface treatments. METHODS Four hundred eighty zirconia discs were prepared by milling and sintering two HT (Katana and BruxZir) and LT (Cercon and Lava) zirconia blocks at targeted dimensions of 12 mm diameter × 1.2 mm thickness. Sintered zirconia discs received one of the following surface treatments: low-pressure airborne particle abrasion (APA) using 50 µm alumina particles, grinding using 400 grit silicon carbide paper, while as-sintered specimens served as control. Internal structure and surface roughness were evaluated by scanning electron microscope (SEM) and a non-contact laser profilometer, respectively. Half of the discs were tested for initial biaxial flexural strength, while the rest was subjected to 106 cyclic fatigue loadings, followed by measuring the residual biaxial flexural strength. Fractured surfaces were examined for critical size defects (c) using SEM to calculate the fracture toughness (KIC). The effect of surface treatments, zirconia type, and cyclic fatigue on the biaxial flexural strength was statistically analyzed using three-way analysis of variance (ANOVA) and Tukey HSD post hoc tests (α = 0.05). Weibull analysis was done to evaluate the reliability of the flexural strength for different materials. RESULTS The initial biaxial flexural strength of LT zirconia was significantly higher (p < 0.001) than that of HT zirconia in all groups. While low APA significantly increased the biaxial flexural strength of LT zirconia, no significant change was observed for HT zirconia except for Katana. Surface grinding and cyclic fatigue significantly reduced the flexural strength of all groups. High translucency zirconia reported higher fracture toughness, yet with lower Weibull moduli, compared to LT zirconia. CONCLUSION LT zirconia has higher biaxial flexural strength, yet with lower fracture toughness and fatigue resistance, compared to HT zirconia. Low-pressure APA has significantly increased the biaxial flexural strength in all zirconia groups except BruxZir. Grinding was deteriorating to biaxial flexural strength and fracture toughness in all zirconia types. Cyclic fatigue has significantly decreased the biaxial flexural strength and reliability of HT and LT zirconia.
Collapse
Affiliation(s)
- Alaaeldin Elraggal
- Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
| | - Moustafa Aboushelib
- grid.7155.60000 0001 2260 6941Dental Biomaterials Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Islam M. Abdel Raheem
- grid.7155.60000 0001 2260 6941Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Rania R. Afifi
- grid.7155.60000 0001 2260 6941Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| |
Collapse
|
11
|
Li S, Zhang X, Xia W, Liu Y. Effects of surface treatment and shade on the color, translucency, and surface roughness of high-translucency self-glazed zirconia materials. J Prosthet Dent 2022; 128:217.e1-217.e9. [PMID: 35817621 DOI: 10.1016/j.prosdent.2022.05.014] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 05/03/2022] [Accepted: 05/04/2022] [Indexed: 11/28/2022]
Abstract
STATEMENT OF PROBLEM The impact of different surface treatments and shades on the color, translucency, and surface roughness of high-translucency self-glazed zirconia materials is unclear. PURPOSE The purpose of this in vitro study was to investigate the effects of different external surface treatments (self-glazed, milled, polished, and glazed), intaglio surface treatments (milled and airborne-particle abraded), and shades (A1 and A3 shades) on the color, translucency, and surface roughness of high-translucency self-glazed zirconia materials, as well as the correlations among optical parameters, translucency, and surface roughness. MATERIAL AND METHODS Eighty shade A1 and 80 shade A3 disks were fabricated with a thickness of 0.80 ±0.02 mm and divided into 16 groups (n=10). Different external and intaglio surface treatments were applied to the specimens. CIELab values were measured with a spectrophotometer, and color differences (ΔE00) and relative translucency parameter (RTP) were calculated. Total transmittance (Tt%) and reflectance (R%) were tested with a spectrophotometer equipped with an integrating sphere. Surface roughness (Ra and Rz) (μm) was measured with a noncontact 3-dimensional laser scanning microscope. One specimen from each group was subjected to scanning electron microscope (SEM) examination. Data were analyzed with ANOVA and the Tukey post hoc test. The correlation among optical parameters, translucency, and surface roughness was investigated by using Pearson correlation analysis (α=.05). RESULTS The effects of external surface treatments, intaglio airborne-particle abrasion, and shades on ΔE00, RTP, and Ra values of the disks were significantly different (P<.001). The smoothest external polishing surface had the greatest RTP and color difference (P<.001). Shade A3 disks had lower RTP and Tt% values than shade A1 disks (P<.001). ΔE00 had a highly positive relationship with the RTP (A1: r=0.884, P<.001; A3: r=0.859, P<.001). SEM images demonstrated that surface treatments affected the surface texture of monolithic zirconia ceramics. CONCLUSIONS Different surface treatments affected the surface roughness, translucency, and final color of zirconia materials. The smoothest external polishing surface had the greatest RTP and color difference. Different shades influenced the translucency, as the darker the disk shade, the lower the translucency. The RTP was appropriate as an auxiliary indicator for evaluating the color of a dental ceramic.
Collapse
Affiliation(s)
- Siyu Li
- Assistant Professor, Department of General Dentistry, Peking University School and Hospital of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, PR China
| | - Xinyue Zhang
- Engineer, Center of Digital Dentistry, Peking University School and Hospital of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, PR China
| | - Wei Xia
- Associate Professor, Department of Engineering Science, Uppsala University, Uppsala, Sweden
| | - Yihong Liu
- Associate Professor, Department of General Dentistry, Peking University School and Hospital of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, PR China.
| |
Collapse
|
12
|
Hsu WC, Peng TY, Kang CM, Chao FY, Yu JH, Chen SF. Evaluating the Effect of Different Polymer and Composite Abutments on the Color Accuracy of Multilayer Pre-Colored Zirconia Polycrystal Dental Prosthesis. Polymers (Basel) 2022; 14:polym14122325. [PMID: 35745899 PMCID: PMC9229389 DOI: 10.3390/polym14122325] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 06/03/2022] [Accepted: 06/07/2022] [Indexed: 12/25/2022] Open
Abstract
With increasing aesthetic awareness and emphasis on time costs in today’s society, monolithic multilayer precolored zirconia ceramics (M-Zr) facilitate aesthetic restorations in a convenient and straightforward manner without the need for veneering porcelain to modify the color. However, the effect of abutment materials on the final color of M-Zr remains unclear. Herein, we placed Vita A1 Shade M-Zr on six different abutment materials, zirconia (Y-TZP), 3D printed composite resin (CR), dental model resin (MR), polyetheretherketone (PEEK), polyetherketoneketone (PEKK), and cobalt−chromium alloy (Co−Cr), to evaluate their effect on the color accuracy of M-Zr. The color attributes (L*, a*, and b*) were measured using a dental spectrophotometer. The translucency parameter (TP), contrast ratio, color difference (ΔE) between each background substrate and the Vita A1 Shade Guide, and chroma values (C) were calculated to evaluate the color accuracy of M-Zr. A statistical analysis was performed using one-way analysis of variance and post hoc Tukey’s HSD tests (α = 0.05). The experimental results indicate that the TP values and contrast ratio of the M-Zr samples were 14.85 and 0.83, respectively. Co−Cr had the highest ΔE (6.08) and lowest C value (7.52); PEKK had the lowest ΔE (2.60), and PEEK had the highest C value (12.23) (p < 0.05). Notably, the ΔE values of CR (3.13), PEEK (2.86), and PEKK were within clinical indicators (ΔE < 3.7). Based on these results, it can be concluded that the abutment material has a significant effect on the final color of the M-Zr, and PEEK or PEKK resulted in good color accuracy. When choosing the dental MR, traditional zirconia, or metals as abutment materials, colored or opaque cement might be required to eliminate color distortion and achieve desirable optical properties.
Collapse
Affiliation(s)
- Wen-Chieh Hsu
- School of Dentistry, College of Dentistry, China Medical University, Taichung 40402, Taiwan;
| | - Tzu-Yu Peng
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan;
| | | | - Fan-Yi Chao
- Department of Physiology and Biophysics, University of Colorado School of Medicine, Aurora, CO 80045, USA;
| | - Jian-Hong Yu
- School of Dentistry, College of Dentistry, China Medical University, Taichung 40402, Taiwan;
- Correspondence: (J.-H.Y.); (S.-F.C.); Tel.: +886-4-2205-3366 (ext. 2309) (S.-F.C.)
| | - Su-Feng Chen
- School of Dentistry, College of Dentistry, China Medical University, Taichung 40402, Taiwan;
- Correspondence: (J.-H.Y.); (S.-F.C.); Tel.: +886-4-2205-3366 (ext. 2309) (S.-F.C.)
| |
Collapse
|
13
|
Alkurt M, Duymus ZY, Yildiz Ş. How home bleaching agents affect the color and translucency of CAD/CAM monolithic zirconia materials. Dent Mater J 2022; 41:511-519. [PMID: 35584933 DOI: 10.4012/dmj.2021-002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
To assess the effect of 10% carbamide peroxide (CP) and 6% hydrogen peroxide (HP) home bleaching agents on the translucency and color of monolithic zirconia. Ninety disc specimens were fabricated (diameter, 10 mm) from multi-layered (ML), ultra translucent multi-layered (UTML), and super translucent multi-layered (STML) zirconia blocks at three thicknesses (0.4,1,1.5 mm) (n=5). The samples were divided into two subgroups, which were treated with 6% HP (45 min per day) or 10% CP (8 h per day) for 14 days. The color of specimens was measured before bleaching (T0) and after bleaching on the third (T3), seventh (T7), and 14th (T14) day. Color (∆E) and translucency (TP) changes were calculated. The thickness varieties used in the samples and the bleaching agent types used created statistically significant differences only in TP and ∆E00, respectively (p<0.05). Bleaching agents can affect TP and ∆E. Patients who have zirconia restorations should be careful when using home bleaching agents.
Collapse
Affiliation(s)
- Murat Alkurt
- Department of Prosthodontics, Faculty of Dentistry, Recep Tayyip Erdogan University
| | - Zeynep Yesil Duymus
- Department of Prosthodontics, Faculty of Dentistry, Recep Tayyip Erdogan University.,Department of Prosthodontics, Faculty of Dentistry, Atatürk University
| | - Şeyma Yildiz
- Department of Prosthodontics, Faculty of Dentistry, Recep Tayyip Erdogan University
| |
Collapse
|
14
|
Woo M, Anunmana C, Eiampongpaiboon T. Influence of zirconia/glass veneer thickness and implant abutment material on the final shade of implant restorations. J Indian Prosthodont Soc 2022; 22:272-278. [PMID: 36511058 PMCID: PMC9416959 DOI: 10.4103/jips.jips_179_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
Aim The aim of this study was to investigate the combined effect of ceramic material, ceramic thickness, and implant abutment background to the final color of restorations. Settings and Design This was a comparative in vitro study. Materials and Methods Three different types of monolithic and porcelain-veneered zirconia disc-shaped specimens (Prettau Anterior, VITA YZ ST, and VITA YZ HT) were prepared in A3 shade with two different thicknesses (1 mm and 1.5 mm) (n = 10). Each zirconia material was made of 4-mm thickness as a control specimen of each monolithic zirconia type, and 4-mm thick veneering ceramic (VITA VM9 Base Dentine) was made as a control for veneered zirconia groups. Three simulated implant abutments were fabricated from titanium, white-shaded and yellow-shaded zirconia. The zirconia specimens were placed on different abutment backgrounds, and the color difference (ΔE) between experimental and control specimens was measured. Statistical Analysis Used The three-way ANOVA and the Scheffé test were used for data analysis (α = 0.05). Results The mean ΔE values between two thicknesses were significantly different in every background for all zirconia materials. The ΔE values of zirconia specimens on yellow zirconia were lower than those of other abutments. The clinically acceptable ΔE value (ΔE <3) was found in some monolithic zirconia specimens on white-shaded and yellow-shaded abutments, while the ΔE value is approximately 3 or less in all 1.5-mm thick porcelain-veneered zirconia groups. Conclusions Different zirconia materials on implant abutments affected the final color of restorations. To achieve satisfactory color, the minimum thickness of zirconia restorations should be at least 1.5 mm on yellow zirconia abutment.
Collapse
Affiliation(s)
- Manita Woo
- Dental Implant Center, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
| | - Chuchai Anunmana
- Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
| | - Trinuch Eiampongpaiboon
- Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand,Address for correspondence: Dr. Trinuch Eiampongpaiboon, Department of Prosthodontics, Faculty of Dentistry, Mahidol University, 6 Yothi Road, Ratchathewi, Bangkok 10400, Thailand. E-mail:
| |
Collapse
|
15
|
Li S, Wang Y, Tao Y, Liu Y. Effects of surface treatments and abutment shades on the final color of high-translucency self-glazed zirconia crowns. J Prosthet Dent 2021; 126:795.e1-795.e8. [PMID: 34711407 DOI: 10.1016/j.prosdent.2021.09.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 09/01/2021] [Accepted: 09/03/2021] [Indexed: 02/04/2023]
Abstract
STATEMENT OF PROBLEM Achieving excellent esthetics with monolithic self-glazed zirconia crowns in anterior teeth is challenging, and the impact of different surface treatments and abutment shades on the final color is unclear. PURPOSE The purpose of this in vitro study was to evaluate the effects of different external surface treatments (self-glazed, milled, polished, and glazed), different intaglio surface treatments (milled and airborne-particle abraded), and different abutment shades on the color difference of high-translucency self-glazed zirconia crowns. MATERIAL AND METHODS Sixty shade A1 and 60 shade A3 crowns were fabricated with a thickness of 0.80 ±0.02 mm and randomly divided into 12 groups (n=10). Different external and intaglio surface treatments were applied. Shade A1 and A3 abutments were made with composite resin. Color was measured with a spectrophotometer and expressed in CIELab coordinates, and color differences (ΔE00) between specimens and references were calculated. The data were analyzed with ANOVA and the Tukey post hoc test. The impact of different surface treatments and abutment shades on the color difference were compared by using multiple linear regression (α=.05). RESULTS The effects of external surface treatments, intaglio airborne-particle abrasion, and abutment shades on the L∗, a∗, b∗ and ΔE00 values of the final color of the crowns were significantly different (P<.001). Polishing resulted in the greatest ΔE00 value among all external surface treatments (P<.001). The average ΔE00 values of all crowns on the A3 abutment were higher than those of all crowns on the A1 abutment (P<.001). The influence on the color difference was abutment>external surface treatment>intaglio surface treatment. CONCLUSIONS Different surface treatments affected the final color of zirconia crowns, and a greater impact was seen with external surface treatments than with intaglio surface treatments. External polishing resulted in the greatest color difference. The abutment shade had the most effect on the color difference, as the darker the abutment color, the greater the color difference.
Collapse
Affiliation(s)
- Siyu Li
- Assistant Professor, Department of General Dentistry, Peking University School and Hospital of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, PR China
| | - Yong Wang
- Professor, Center of Digital Dentistry, Peking University School and Hospital of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, PR China
| | - Yongqing Tao
- Senior Technician, Dental Laboratory Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, PR China
| | - Yihong Liu
- Associate Professor, Department of General Dentistry, Peking University School and Hospital of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, PR China.
| |
Collapse
|
16
|
Effect of external staining on the optical properties and surface roughness of monolithic zirconia of different thicknesses. J Prosthet Dent 2021; 126:687.e1-687.e8. [PMID: 34657728 DOI: 10.1016/j.prosdent.2021.08.014] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2020] [Revised: 08/21/2021] [Accepted: 08/23/2021] [Indexed: 11/24/2022]
Abstract
STATEMENT OF PROBLEM The effect of the number of external staining applications on the color, translucency, and surface roughness of monolithic zirconia is not known. PURPOSE The purpose of this in vitro study was to investigate the effect of glazing and repeated external staining on the color, translucency, and surface roughness of 2 types of monolithic zirconia with 2 different thicknesses. MATERIAL AND METHODS Thirty-two 10×10-mm monolithic zirconia blocks, of which 16 were super high translucent and 16 were high translucent, were milled. The thickness of half the blocks was 0.7 mm, and the others were 1.2-mm thick. Four specimens in each subgroup were colored with value stain, and the other half with yellow stain. Staining was repeated twice for each specimen. The color and translucency of each specimen were measured before overglazing as the baseline, after overglazing, and after each staining process by using a spectrophotometer. The surface roughness (Ra) was measured after overglazing, the first staining, and the second staining. Data were analyzed by using repeated measures ANOVA and the independent t test (α=.05). RESULTS The number of coloring, type of coloring, and thickness changed the optical properties of monolithic zirconia. a∗, b∗, L∗ Value and ΔE were affected by the stage of firing (glazing, first staining, and second staining) (P<.001). ΔE Increased after the first and second staining in each type and thickness of monolithic zirconia and each type of stain. The amount of ΔE change was more for the first staining stage. The color difference (ΔE) after overglazing ranged from 3.08 to 3.75. The highest changes in color were related to the first staining with yellow colorant of super-high-translucent monolithic zirconia (cubeX²) with 0.7-mm thickness (ΔE=17.62). The surface roughness of the specimens was affected by the number of colorings (P<.001). In all groups, the first staining increased the surface roughness, and the second staining decreased the surface roughness. The type of monolithic zirconia (P=.756), thickness (P=.735), and type of stain (P=.239) had no significant effect on the surface roughness. CONCLUSIONS The first stage of staining with both stains caused more color change in all types and thicknesses of monolithic zirconia. Translucency increased after glazing and decreased after the first and second staining. The first staining increased the surface roughness, and the second decreased the surface roughness.
Collapse
|
17
|
Effects of thickness of different types of high-translucency monolithic multilayer precolored zirconia on color accuracy: An in vitro study. J Prosthet Dent 2021; 126:587.e1-587.e8. [PMID: 34446291 DOI: 10.1016/j.prosdent.2021.07.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 07/16/2021] [Accepted: 07/16/2021] [Indexed: 11/21/2022]
Abstract
STATEMENT OF PROBLEM High-translucency monolithic multilayer precolored zirconia provides acceptable esthetics and eliminates chipping of the veneering porcelain. However, the color is not always consistent with the standard Vita shade guide, and the color saturation may vary with the thickness of the zirconia. PURPOSE The purpose of this in vitro study was to characterize the effect of thickness on the color accuracy of high-translucency monolithic multilayer precolored zirconia. MATERIAL AND METHODS Plate-shaped (20×20 mm) Vita A2 shade high-translucency monolithic multilayer precolored zirconia specimens of 3 types (SHT Multilayer, AT Multilayer, and 3D Multilayer) in 4 thicknesses (0.5, 1.0, 1.5, and 2.0 mm) were fabricated (N=120, n=10). A spectrophotometer was used to measure the color attributes (CIELab) against gray or A2 substrates to evaluate the color accuracy based on differences in color (ΔE) (versus the Vita shade guide) and chroma. Statistical analysis was performed by using the Pearson correlation, 2-way ANOVA, and post hoc Scheffé test (α=.05). RESULTS Against gray substrates, thickness was significantly positively correlated with all color attributes. Against A2 substrates, L∗ values increased with an increase in thickness; however, a∗, b∗, and chroma values remained stable. Zirconia with a thickness of 1.0 mm exhibited the lowest ΔE, regardless of the type, except for AT Multilayer against A2 substrates, where the lowest ΔE was achieved at 0.5 mm. At thicknesses ≥1.0 mm, the ΔE between the 2 substrates was imperceivable. CONCLUSIONS Thickness affected the color accuracy of different high-translucency monolithic multilayer precolored zirconia types. It appears that the optimal thickness in terms of color accuracy is 1.0 mm. These results could be used as a reference for the selection and preparation of abutments in clinical applications.
Collapse
|
18
|
Manziuc MM, Gasparik C, Burde AV, Dudea D. Color and masking properties of translucent monolithic zirconia before and after glazing. J Prosthodont Res 2021; 65:303-310. [PMID: 33116028 DOI: 10.2186/jpr.jpr_d_20_00039] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Purpose 1. to assess the ability of four brands of translucent monolithic zirconia with different thicknesses to mask discolored substrates; 2. to assess the influence of glazing upon their color coordinates and masking properties.Methods Sixty samples of shade A1 (0.8, 1.5, and 2.0 mm thickness) from: ZirCAD/MT, Katana/HT, Vita YZ/HT, Cercon/HT were fabricated and glazed using a standardized laboratory procedure. CIE L*a*b* parameters were recorded on composite substrates, (IPS Natural Die Material Kit) (ND1=reference; ND2, ND3, ND4, ND5=test backgrounds), before and after glazing. The color changes of zirconia samples induced by glazing were analyzed. Masking properties was calculated as the color difference between CIE L*a*b* parameters of the samples placed on reference and test substrates with CIEDE2000(1:1:1) formula. The effect of material, thickness, substrate, and glazing on the color of monolithic zirconia was analyzed with ANOVA test and the multiple comparisons were analyzed with Tukey HSD tests (α=0.05).Results After glazing, lightness L* significantly increased, while chromatic coordinates a* and b* decreased (p<0.05). Significant differences in the masking properties of the four materials (p<0.001) were found, with IPS e.max ZirCAD/MT having the lowest masking effect (p<0.001). Thickness, substrate and glazing had a significant effect on the color masking properties of monolithic zirconia (p<0.001).Conclusions Masking properties of translucent zirconia were significantly influenced by the materials, the thickness and the color of the substrate; moreover, glazing improved the masking ability for all zirconia samples.
Collapse
Affiliation(s)
- Manuela Maria Manziuc
- Department of Prosthetic Dentistry and Dental Materials, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Cristina Gasparik
- Department of Prosthetic Dentistry and Dental Materials, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Alexandru Victor Burde
- Department of Prosthetic Dentistry and Dental Materials, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Diana Dudea
- Department of Prosthetic Dentistry and Dental Materials, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| |
Collapse
|
19
|
Blackburn J, Jackson T, Cook R, Sulaiman TA. Optical properties of a novel glass-ceramic restorative material. J ESTHET RESTOR DENT 2021; 33:1160-1165. [PMID: 34365726 DOI: 10.1111/jerd.12809] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 07/17/2021] [Accepted: 07/29/2021] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To examine the optical properties of a dental restorative material manufactured from lithium aluminosilicate ceramic and reinforced with lithium disilicate. Translucency and the optical effects of various supporting materials on color were the primary focus. METHODS Five 10 × 10 mm samples were prepared in thicknesses of 0.5, 1.0, 1.5, and 2.0 mm of both high translucency (HT) and low translucency (LT) versions of the material in shade A3. A spectrophotometer was used to measure the illuminance of the samples with black and white backings in order to calculate contrast ratio (CR) and relative translucency parameter (RTP). A baseline relationship between translucency and material thickness was examined and the effects of composite, titanium, and zirconia abutments on color change were studied. RESULTS No significant findings were identified for RTP or CR between the HT and LT material, regardless of the material thickness (p = 0.39, p = 0.14, respectively). Regardless of material thickness (HT vs. LT), translucencies (RTP and CR) were significantly different with composite, titanium, and zirconia backings compared to baseline values (p < 0.0001). Titanium had the most significant decrease in translucency compared to composite and zirconia. There was no difference in ΔE00 between the HT and LT materials (p > 0.05) regardless of the backing. Titanium had the most significant effect on color of both materials followed by composite then zirconia (p < 0.0001). CONCLUSIONS There is not a clinically significant difference in translucency between the high translucency and low translucency materials. Only zirconia supporting structures produced changes in color that are clinically acceptable. CLINICAL SIGNIFICANCE Understanding the optical properties of glass-ceramic restorative materials aids providers in selecting appropriate materials for optimum esthetic outcomes. The lithium-aluminosilicate reinforced with lithium disilicate material does a poor job masking supporting structures and resisting color change.
Collapse
Affiliation(s)
- Jackson Blackburn
- Division of Comprehensive Oral Health, University of North Carolina, Adams School of Dentistry, Chapel Hill, North Carolina, USA
| | - Tate Jackson
- Graduate Orthodontics Program, Division of Craniofacial and Surgical Care, University of North Carolina, Adams School of Dentistry, Chapel Hill, North Carolina, USA
| | - Ryan Cook
- Graduate Prosthodontics Program, Division of Comprehensive Oral Health, University of North Carolina, Adams School of Dentistry, Chapel Hill, North Carolina, USA
| | - Taiseer A Sulaiman
- Division of Comprehensive Oral Health, University of North Carolina, Adams School of Dentistry, Chapel Hill, North Carolina, USA
| |
Collapse
|
20
|
Jung J, Roh BD, Kim JH, Shin Y. Masking of High-Translucency Zirconia for Various Cores. Oper Dent 2021; 46:54-62. [PMID: 33351930 DOI: 10.2341/19-238-l] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/26/2019] [Indexed: 11/23/2022]
Abstract
CLINICAL RELEVANCE Various core materials with different shades affect the final color of high-translucency monolithic zirconia restorations. The blue core shows the greatest color difference in final zirconia restorations followed by metal, A3 dentin-shade resin core, and white core. SUMMARY The purpose of this study was to evaluate the masking ability of high-translucency monolithic zirconia for various core materials. A computer-aided design-computer-aided manufacturing system was used to design a zirconia disc with a diameter of 10 mm and a thickness of 1.0 mm. Four groups of cores (n=15 each) were fabricated with blue-colored dual-cure resin, white-colored dual-cure resin, A3 dentin-shade composite resin, and titanium block with 10-mm diameter and 5-mm thickness.Dual-cure, self-adhesive resin cement discs with a thickness of 25.0 ± 0.02 μm were fabricated. The color was measured using a handheld spectrophotometer. Color measurements of all specimens were performed on a white background. To assess the masking ability of zirconia, the difference between the values measured with zirconia on a white background and the values measured with zirconia on each of the four types of core material as a background with the cement specimens interposed (zirconia + cement + core) was determined. To enhance the optical connection between the specimens, distilled water was applied between each layer during each measurement.The results showed that the value of ΔE was highest for the blue core followed by metal, A3 dentin-shade resin core, and white-resin core. No significant differences were observed between the metal core and the A3 dentin-shade resin core or between the A3 dentin-shade resin core and the white core. The blue core had the significantly highest ΔE value based on Tukey's honest significant difference test.Different core materials affect the final color of high-translucency monolithic zirconia restorations. Thus, our study showed that the final color of high-translucency monolithic zirconia restorations could be affected by the type of core material used.
Collapse
|
21
|
Ruiz-López J, Pulgar R, Lucena C, Pelaez-Cruz P, Cardona JC, Perez MM, Ghinea R. Impact of short-term dental dehydration on in-vivo dental color and whiteness. J Dent 2021; 105:103560. [PMID: 33352224 DOI: 10.1016/j.jdent.2020.103560] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2020] [Revised: 12/04/2020] [Accepted: 12/10/2020] [Indexed: 10/22/2022] Open
Abstract
OBJECTIVE To determine in-vivo chromatic and whiteness changes produced by short-term dental dehydration. METHODS Spectral reflectance of 452 upper incisors (226 centrals and 226 laterals) of 113 participants were measured using a spectroradiometer at baseline and after short-term dehydration (minutes 2, 4, 6, 8 and 10). CIE L*a*b* color coordinates (L*, a*, b*, C*ab and hab) and whiteness index for dentistry (WID) were calculated. Color differences (ΔE00, ΔEab*) and whiteness differences (ΔWID) were computed and interpreted based on their respective 50:50% perceptibility (PT) and acceptability thresholds (AT). Statistical analysis was performed using the related samples Wilcoxon signed-rank test. RESULTS L* showed an increasing trend with dehydration, while a*, b*, C*ab and hab have a decreasing tendency. All chromatic coordinates showed statistically significant differences (p < 0.003) at each interval of dehydration compared with baseline, except a* for all teeth. For ΔE00 and ΔEab* values were higher than PT after 2 min of teeth dehydration and higher than AT after 6 and 8 min, respectively. The percentage of teeth exceeding corresponding PT was higher than 50% after 2 min. WID index increased with dehydration time, while whiteness differences were clinically perceptible after 4 min. Statistically significant differences were found for WID between all dehydration intervals (except 8-10 min). The percentage of teeth exceeding whiteness PT was higher than 50% after 6 min of teeth dehydration. CONCLUSIONS Short-term dental dehydration produces clinically unacceptable changes in tooth color and clinically perceptible increase in tooth whiteness level. CLINICAL SIGNIFICANCE Clinical shade matching must be done within the first two minutes of any clinical procedure that requires precise chromatic determination but implies a risk of tooth dehydration.
Collapse
Affiliation(s)
- Javier Ruiz-López
- Department of Optics, Faculty of Science, University of Granada, Campus Fuente Nueva, Edificio Mecenas, S/N 18071, Granada, Spain.
| | - Rosa Pulgar
- Department of Stomatology, Faculty of Dentistry, University of Granada, Campus de Cartuja S/N, Granada, 18071, Spain.
| | - Cristina Lucena
- Department of Stomatology, Faculty of Dentistry, University of Granada, Campus de Cartuja S/N, Granada, 18071, Spain.
| | - Priscilla Pelaez-Cruz
- Department of Stomatology, Faculty of Dentistry, University of Granada, Campus de Cartuja S/N, Granada, 18071, Spain.
| | - Juan C Cardona
- Department of Optics, Faculty of Science, University of Granada, Campus Fuente Nueva, Edificio Mecenas, S/N 18071, Granada, Spain.
| | - Maria M Perez
- Department of Optics, Faculty of Science, University of Granada, Campus Fuente Nueva, Edificio Mecenas, S/N 18071, Granada, Spain.
| | - Razvan Ghinea
- Department of Optics, Faculty of Science, University of Granada, Campus Fuente Nueva, Edificio Mecenas, S/N 18071, Granada, Spain; Department of Physics, Faculty of Sciences, University of Craiova, 13 AI Cuza Street, Craiova, 200585, Romania.
| |
Collapse
|
22
|
Kang CM, Peng TY, Shimoe S. Color accuracy of different types of monolithic multilayer precolored zirconia ceramics. J Prosthet Dent 2020; 124:789.e1-789.e7. [PMID: 32778469 DOI: 10.1016/j.prosdent.2020.04.026] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 04/28/2020] [Accepted: 04/28/2020] [Indexed: 11/16/2022]
Abstract
STATEMENT OF PROBLEM The use of monolithic multilayer precolored zirconia facilitates the production of esthetic restorations in a convenient and straightforward manner. However, the accuracy of the final color is not clear. PURPOSE The purpose of this in vitro study was to determine the color accuracy of different types of monolithic multilayer precolored zirconia ceramics of varying thicknesses. MATERIAL AND METHODS Eighty cubical A2-shade monolithic multilayer precolored zirconia ceramic specimens (15×15 mm) of 2 different thicknesses (1.0 mm and 1.5 mm) and 4 zirconia brands (UPCERA EXPLORE [UPEX], KATANA Zirconia STML [STML], Enamel ZR Multi-5 [EZM5], and Aidite 3D Pro Zir [A3DM]) were fabricated and divided into 8 groups (n=10). The Commission Internationale de l'Eclairage (CIELab) values were measured against 3 different backing substrates (gray, transparent, and A2) by using a spectrophotometer. The color difference (ΔE) between the backing substrates of each group and the Vita A2 Shade Guide, translucency parameter (TP), and chroma (C) values were calculated to evaluate the accuracy of the final color. Statistical analysis was performed by using ANOVA and the post hoc Tukey HSD tests (α=.05). RESULTS The ΔE values for UPEX and STML exceeded the clinically acceptable thresholds for gray and transparent backing substrates (ΔE>3.7) and were higher than those for the A2 backing substrate. A3DM showed less ΔE from the shade guide for all the backing substrates (P<.05), and the corresponding ΔE values were within the clinically acceptable threshold (ΔE<3.7). The TP value was inversely proportional, and the C value was proportional to thickness. For the zirconia ceramics with identical thicknesses, UPEX and STML exhibited the highest TP values, and A3DM showed the lowest C value (P<.05). CONCLUSIONS At a specific thickness, color accuracy was mainly affected by the type of monolithic multilayer precolored zirconia ceramic, and the high transparency of ceramics will cause color differences.
Collapse
Affiliation(s)
- Chien-Ming Kang
- Dental Technician, Huayi Dental Laboratory, Taipei, Taiwan, Republic of China
| | - Tzu-Yu Peng
- Research Assistant, Department of Anatomy and Functional Restorations, Hiroshima University Graduate School of Biomedical and Health Sciences, Hiroshima, Japan; Postdoctoral Researcher, School of Dentistry, College of Dentistry, China Medical University, Taichung, Taiwan, Republic of China
| | - Saiji Shimoe
- Associate Professor, Department of Anatomy and Functional Restorations, Hiroshima University Graduate School of Biomedical and Health Sciences, Hiroshima, Japan.
| |
Collapse
|
23
|
Herpel C, Rammelsberg P, Rues S, Zenthöfer A, Seceleanu I, Corcodel N. Color stability of individually stained monolithic zirconia following occlusal adjustment. J ESTHET RESTOR DENT 2020; 33:387-393. [PMID: 32609416 DOI: 10.1111/jerd.12620] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Revised: 05/13/2020] [Accepted: 06/10/2020] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To meet esthetic requirements, monolithic zirconia can be stained by color-infiltration. However, adjustments of occlusal surfaces are often necessary, leading to demasking effects if too much of the color-infiltrated layer is removed. The effect of subsequent material removal on color stability of individually stained zirconia is analyzed here. MATERIALS AND METHODS Thirty-six white zirconia disks were divided into three groups. Standardized staining strategies for tooth colors VITA A2, A3.5, and A4 were developed and applied to the disks. Samples were grinded in nine successive steps from 20 to 500 μm. A spectroradiometer was used to measure the color differences after each step. Regression analyses were performed for color differences from baseline as a function of depth of material removal. Depth of material removal resulting in color changes surpassing the acceptability threshold of ΔE00 = 1.8 was estimated using inverse prediction. RESULTS Up to 500 μm material removal, color difference ΔE00 changes linearly with the depth of material removal (P < 0.05). Regression analyses showed coefficients of determination (R2 ) of 0.97 (VITA A2), 0.87 (VITA A3.5), and 0.96 (VITA A4). Acceptability threshold was surpassed at 62, 87, and 92 μm, respectively. CONCLUSIONS Discolorations occur within clinically relevant occlusal adjustments of <100 μm. The effect is more severe with lighter, less saturated tooth colors. CLINICAL SIGNIFICANCE Staining that is resistant to occlusal adjustments and abrasion is only possible if the staining solution infiltrates sufficiently deep into the ceramic structure. This study provides for the first time in the literature numerical values that describe the thresholds of acceptability of color differences in zirconia ceramics. These values are essential because they determine the extent of possible occlusal adjustments, and thus the color stability. Further research is necessary to improve the infiltration depth of staining solutions.
Collapse
Affiliation(s)
- Christopher Herpel
- Department of Prosthodontics, University of Heidelberg, Heidelberg, Germany
| | - Peter Rammelsberg
- Department of Prosthodontics, University of Heidelberg, Heidelberg, Germany
| | - Stefan Rues
- Department of Prosthodontics, University of Heidelberg, Heidelberg, Germany
| | - Andreas Zenthöfer
- Department of Prosthodontics, University of Heidelberg, Heidelberg, Germany
| | - Irina Seceleanu
- Department of Mathematics, Bridgewater State University, Bridgewater, Massachusetts, USA
| | - Nicoleta Corcodel
- Department of Prosthodontics, University of Heidelberg, Heidelberg, Germany
| |
Collapse
|
24
|
Tabatabaian F, Karimi M, Namdari M. Color match of high translucency monolithic zirconia restorations with different thicknesses and backgrounds. J ESTHET RESTOR DENT 2020; 32:615-621. [DOI: 10.1111/jerd.12596] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Revised: 04/19/2020] [Accepted: 05/04/2020] [Indexed: 11/29/2022]
Affiliation(s)
- Farhad Tabatabaian
- Department of ProsthodonticsSchool of Dentistry, Shahid Beheshti University of Medical Sciences Tehran Iran
| | | | - Mahshid Namdari
- Department of Community Oral HealthSchool of Dentistry, Shahid Beheshti University of Medical Sciences Tehran Iran
| |
Collapse
|
25
|
Effect of coloring liquids on color of zirconia frameworks and bond strength of zirconia/veneering ceramic. J Prosthet Dent 2020; 124:110-115. [PMID: 32204927 DOI: 10.1016/j.prosdent.2020.01.028] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Revised: 01/16/2020] [Accepted: 01/16/2020] [Indexed: 11/22/2022]
Abstract
STATEMENT OF PROBLEM Zirconia substructures must be colored to fabricate esthetic restorations. However, the coloring procedure may affect the color match and bond strength of the veneering ceramic to the zirconia. PURPOSE The purpose of this in vitro study was to evaluate the bond strength of veneering ceramic to zirconia after dipping in coloring liquid for different durations and to compare the color of dipped blocks with precolored blocks. MATERIAL AND METHODS Sixty-four cube-shaped specimens were fabricated from uncolored zirconia blocks by using computer-aided design and computer-aided manufacturing and divided into 4 groups (n=16). The G30 group was subjected to coloring liquids for 30 seconds, G60 for 60 seconds, and G120 for 120 seconds. After the coloring procedures, the color of the specimens was evaluated by using a spectrophotometer. Precolored zirconia (PCZ) was used as the control. Once the color measurements were completed, the same specimens were prepared for the bond strength test, with 2 groups as the control: PCZ and the uncolored control group (control bond-strength [CBS]). Veneering ceramic was applied to the zirconia specimens and sintered. The shear bond test was conducted using universal testing equipment with a crosshead speed of 1 mm/min. Statistical analysis was carried out by using 1-way ANOVA followed by the Tukey HSD test (α=.05). A Weibull analysis was performed, and the Weibull modulus was calculated for each group. RESULTS The mean E value for the PCZ group (77.34 ±0.22) was statistically significantly different from that of all groups (PCZ-G30; P=.018, PCZ-G60; P= <.001, PCZ-G120; P<.001). The mean E value for G60 group was significantly different from mean E values of the G30 and G120 groups (G60-G30; P<.001, G60-G120; P<.001). The PCZ group had the highest mean shear bond strength value (31.5 ±7.67 MPa) and was significantly different from the mean bond strength values of the G120 and CBS groups (PCZ-G120; P=.008, PCZ-CBS; P<.001). The CBS had the lowest mean bond strength value (16.62 ±7.11 MPa) and was statistically significantly lower than that of the G60 group (CBS-G60; P=.001). The Weibull modulus was 64.78 for the PCZ group and 0.1 for the G120 group. CONCLUSIONS Immersing zirconia in coloring liquid altered the color and negatively affected the bond strength between the veneering ceramic and zirconia.
Collapse
|
26
|
Yang M, Xu Z, Zhuang Z. Macrophages affect immune inflammation and proliferation in benign prostatic hyperplasia via androgen receptor and CD40/CD40L signaling pathway. Tissue Cell 2020; 64:101343. [PMID: 32473708 DOI: 10.1016/j.tice.2020.101343] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2019] [Revised: 12/30/2019] [Accepted: 01/22/2020] [Indexed: 12/31/2022]
Abstract
OBJECTIVE Considering the association of macrophage migration inhibitory factor with development of prostate diseases, this study aims to explore the effect and mechanism of macrophages (MAs) in inflammation and proliferation of benign prostate hyperplasia (BPH) cells. METHODS Totally 85 prostate tissues (75 from BPH patients and 10 from brain death patients) were collected for determination of biomarkers of T lymphocyte (CD4 and CD8), B lymphocyte (CD20) and MAs (CD68), as well as androgen receptor (AR) and CD40/CD40L. MAs stimulated by phorbol myristate acetate (PMA) were cultured with BPH cells (BPH-1), followed by AR inhibitor or anti-CD40 L antibody treatment. Proliferation and cell apoptosis were observed by MTT assay, colony formation assay and flow cytometer. Expressions of apoptotic related proteins and MAPK signaling pathway-related proteins were determined by qRT-PCR and Western blot. RESULTS BPH tissues had increased expressions of AR, CD40 and CD40 L, as well as elevated expressions of inflammation biomarkers (CD4, CD8, CD20 and CD68) in comparison to normal prostate tissues. MAs could increase the expressions of lymphocytes and inflammation biomarkers, in addition to promoting cell proliferation and inhibiting cell apoptosis. Cell proliferation and inflammation reaction could be attenuated by anti-CD40 L antibody and AR inhibitor in a concentration dependent manner through inhibiting the phosphorylation of JNK, ERK1/2 and p38. CONCLUSION MAs regulate AR and CD40/CD40L expression to promote the inflammation and proliferation as well as inhibiting apoptosis of BPH-1 cells through activation of the MAPK signaling pathway. This conclusion may provide a therapeutic strategy for BPH patients.
Collapse
Affiliation(s)
- Minggen Yang
- Department of Urology, Zhangzhou Affiliated Hospital of Fujian Medical University, Zhangzhou, Fujian, 363000, PR China
| | - Zhenqiang Xu
- Department of Urology, Zhangzhou Affiliated Hospital of Fujian Medical University, Zhangzhou, Fujian, 363000, PR China.
| | - Zhiming Zhuang
- Department of Urology, Zhangzhou Affiliated Hospital of Fujian Medical University, Zhangzhou, Fujian, 363000, PR China
| |
Collapse
|
27
|
Lebedenko IY, Dyakonenko EE, Sakhabieva DA, Llaka E. [Translucent zirconia ceramics for fabrication monolithic restorations: review. Part 2]. STOMATOLOGIIA 2020; 99:101-106. [PMID: 33267553 DOI: 10.17116/stomat202099061101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Translucent zirconia ceramics for fabrication monolithic restorations is a ceramic material of latest generation. The objective of this literature review is discussing the ways to increase the transparency of zirconia, novel technologies of its manufacturing (part 1) and laboratory procedures for fabrication translucent zirconia restorations, factors affecting the transparency, optical and physico-mechanical properties of the material, as well as indications for its use (part 2).
Collapse
Affiliation(s)
- I Yu Lebedenko
- Central Research Institute of Dental and Maxillofacial Surgery, Moscow, Russia
- Peoples' Friendship University of Russia, Moscow, Russia
| | - E E Dyakonenko
- Central Research Institute of Dental and Maxillofacial Surgery, Moscow, Russia
| | - D A Sakhabieva
- Peoples' Friendship University of Russia, Moscow, Russia
| | - E Llaka
- Peoples' Friendship University of Russia, Moscow, Russia
| |
Collapse
|
28
|
Dai S, Chen C, Tang M, Chen Y, Yang L, He F, Chen B, Xie H. Choice of resin cement shades for a high-translucency zirconia product to mask dark, discolored or metal substrates. J Adv Prosthodont 2019; 11:286-296. [PMID: 31754419 PMCID: PMC6856310 DOI: 10.4047/jap.2019.11.5.286] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2019] [Revised: 10/04/2019] [Accepted: 10/29/2019] [Indexed: 11/08/2022] Open
Abstract
PURPOSE The aim was to study the masking ability of high-translucency monolithic zirconia and provide guidance in selecting resin luting cements in order to mask discolored substrates. MATERIALS AND METHODS 160 high-translucency zirconia specimens were divided into 32 groups depending on their thickness and shades. Using five shades of try-in paste, the specimens were luted onto the sub strates (Co-Cr, precious-metal, opaque porcelain-sintered Co-Cr, opaque porcelain-sintered precious-metal, and 5M3-shade zirconia). All CIELAB color parameters were measured and statistically analyzed. RESULTS Zirconia shade and thickness and try-in paste shade affected CIELAB color parameters (P=.000) in different substrates groups, and there were interactions among these factors (P=.000). All five try-in paste shades can be chosen to achieve ΔE values of zirconia with 1.2 - 1.5 mm for masking dark-tooth-like 5M3-shade and zirconia with 1.5 mm for masking precious-metal groups < 2.6. Only suitable try-in paste shades were used, can ΔE values that less than 2.6 be achieved when applied translucent monolithic zirconia with 0.7-1.0 mm for masking dark-tooth-like 5M3-shade and zirconia with 0.7 - 1.2 mm for masking precious-metal groups. CONCLUSION Choosing suitable resin cement shades is necessary for high-translucency monolithic zirconia to achieve ideal masking ability (ΔE < 2.6) on the dark-tooth.
Collapse
Affiliation(s)
- Shiqi Dai
- Jiangsu Key Laboratory of Oral Diseases; Department of Prosthodontics, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China
| | - Chen Chen
- Jiangsu Key Laboratory of Oral Diseases; Department of Endodontics, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China
| | - Mo Tang
- Jiangsu Key Laboratory of Oral Diseases; Department of Prosthodontics, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China
| | - Ying Chen
- Jiangsu Key Laboratory of Oral Diseases; Department of Prosthodontics, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China
| | - Lu Yang
- Jiangsu Key Laboratory of Oral Diseases; Department of Prosthodontics, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China
| | - Feng He
- Jiangsu Key Laboratory of Oral Diseases; Department of Prosthodontics, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China
| | - Bingzhuo Chen
- Jiangsu Key Laboratory of Oral Diseases; Department of Prosthodontics, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China
| | - Haifeng Xie
- Jiangsu Key Laboratory of Oral Diseases; Department of Prosthodontics, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China
| |
Collapse
|
29
|
Turgut S. Optical properties of currently used zirconia-based esthetic restorations fabricated with different techniques. J ESTHET RESTOR DENT 2019; 32:26-33. [PMID: 31596535 DOI: 10.1111/jerd.12533] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 07/24/2019] [Accepted: 08/28/2019] [Indexed: 11/28/2022]
Abstract
OBJECTIVE The aim was to evaluate the effects of different types of monolithic zirconia (MZ) and fabrication techniques on the optical properties of newly generated zirconia-based materials after aging. MATERIAL AND METHODS Sixty specimens (n = 10) were prepared. For the groups layering-veneering (LV), overpressing (OP), porcelain fused to zirconia (PFZ), and cutback (CB), 3Y-TZP, IPS e.max ZirCAD was prepared as the core material (0.5 ± 0.01 mm). For full-contour (FC) technique, 3Y-TZP was used for MZ-LT (low translucency) and 4Y-TZP was used for MZ-MT (medium translucency). L*, a*, b*, chroma (C), and relative translucency (RTP) were measured before (L1 *, a1 *, b1 *, C1 , RTP1 ) and after (L2 *, a2 *, b2 *, C2 , RTP2 ) UV aging. Statistical analyses were performed by one-way ANOVA with Tukey's test and paired sample t tests (P = .05). RESULTS Fabrication techniques significantly affected the L*, a*, b*, C, RTP, and ΔE00 values (P ˂ .01). The highest L1 * value was found in MZ-LT; followed, in order, by OP, PFZ, LV, CB, and MZ-MT. The highest b1 * and C1 values were found in OP, while MZ-MT had the lowest values (P ˂ .05). FC had the highest RTP values for MZ-MT (13 ± 0.9 RTP1; 11.2 ± 0.9 RTP2 ), and the lowest RTP values were found for MZ-LT (8.5 ± 0.9 RTP1; 8.3 ± 1.2 RTP2 ) (P ˂ .01). Aging caused significant differences in the L*, a*, b*, C, and RTP values (P < .05). The color changes were between 0.9 and 2.1 ΔE00 . CONCLUSIONS The fabrication technique significantly affected the optical properties. UV aging caused zirconia-based restorations to become darker and more yellow, red, saturated, and opaque. CLINICAL IMPLICATIONS Fabrication techniques with different zirconia structures affected the optical properties of the restoration, even when the same shades were chosen. If more translucent restorations are needed, choosing 4-YTZP with the FC technique is better than veneering with 3-YTZP. Choosing 3-YTZP with the FC technique produces more esthetic results if brighter and more opaque restorations are needed.
Collapse
Affiliation(s)
- Sedanur Turgut
- Department of Prosthodontics, Karadeniz Technical University, Trabzon, Turkey
| |
Collapse
|
30
|
Clinical factors affecting the translucency of monolithic Y-TZP ceramics. Odontology 2019; 108:526-531. [DOI: 10.1007/s10266-019-00446-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2019] [Accepted: 08/05/2019] [Indexed: 10/26/2022]
|
31
|
Tabatabaian F, Aflatoonian K, Namdari M. Effects of veneering porcelain thickness and background shade on the shade match of zirconia-based restorations. J Dent Res Dent Clin Dent Prospects 2019; 13:68-74. [PMID: 31217922 PMCID: PMC6571521 DOI: 10.15171/joddd.2019.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2019] [Accepted: 03/17/2019] [Indexed: 11/28/2022] Open
Abstract
Background. Effects of veneering porcelain thickness and background shade on the shade match of zirconia-based restorations are unclear. The aim of this study was to evaluate the impacts of veneering porcelain thickness and background shade on the shade match of zirconia-based restorations.
Methods. Forty A2 shade veneered zirconia disk specimens (10 mm in diameter) were fabricated, with veneering porcelain thicknesses of 1.6, 1.8, 2.0 and 2.2 mm. Three backgrounds were made of A2 shade composite resin (A2), nickel-chromium alloy (NC) and amalgam (AM). The veneered zirconia specimens were placed on the backgrounds. CIELab values were measured with a spectrophotometer. ΔE values were measured to determine color differences between the specimens and the A2 VITA classical shade (target shade). ΔE values were compared with an acceptability threshold (ΔE=3.7). Repeated measures ANOVA, Bonferroni, and 1-sample t-test were used to analyze data (P<0.05).
Results. Mean ΔE values ranged between 1.9 and 5.0. The veneering porcelain thickness, the background shade and their interaction affected the ΔE (P<0.0001). The minimum veneering porcelain thickness for the shade match was 2 mm for NC and 1.8 mm for AM.
Conclusion. Veneering porcelain thickness and background shade affected the shade match of zirconia-based restorations. With dark-shaded backgrounds, the amount of veneering porcelain thickness needed for the shade match might be beyond acceptable clinical limits. Tooth-shaded backgrounds are esthetically advocated rather than dark-shaded backgrounds in zirconia-based restorations.
Collapse
Affiliation(s)
- Farhad Tabatabaian
- Department of Prosthodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | | | - Mahshid Namdari
- Department of Community Oral Health, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
32
|
Pérez MM, Pecho OE, Ghinea R, Pulgar R, Bona AD. Recent Advances in Color and Whiteness Evaluations in Dentistry. ACTA ACUST UNITED AC 2019. [DOI: 10.2174/2542579x01666180719125137] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
The final goal of color measurement or shade specification in dentistry is
the reproduction by prosthetic materials of all important appearance characteristics of natural oral
structures. The application of color science in dentistry is an objective way to measure and evaluate
such structures and dental materials in clinical practice and dental research.
Methods:
Literature on color science was reviewed to present new metrics to evaluate color differences
of dental materials and dental structures. Visual acceptability and perceptibility values of color
differences are reviewed and new whiteness indexes to describe whiteness in dentistry are presented.
Results:
In the last decade, the CIELAB 50:50% perceptibility and acceptability thresholds were set
to 1.2 and 2.7, respectively, and the CIEDE2000 50:50% perceptibility and acceptability thresholds
were set to 0.8 and 1.8. The CIEDE2000 color-difference formula became increasingly popular in
dentistry. Developments in color science have led to the description of tooth whiteness and changes
in tooth whiteness based on whiteness indexes, with the most relevant being the WID whiteness index,
which is a customized index based in CIELAB color space.
Conclusion:
The application of color science in dentistry has allowed the precise description of
tooth color and whiteness. The revised and new CIEDE2000 color-difference formula is expected to
fully replace the outdated CIELAB formula in almost all dental applications. Recent psychophysical
studies have reported values of visual thresholds and new whiteness indexes, which can serve as
quality control tools to guide the selection of esthetic dental materials, evaluate clinical performance,
and interpret visual and instrumental findings in clinical dentistry, dental research, and subsequent
standardization.
Collapse
Affiliation(s)
- María M. Pérez
- Department of Optics, Faculty of Science, Campus Fuente Nueva, Edificio Mecenas, s/n E-18071, University of Granada, Spain
| | - Oscar E. Pecho
- Department of Optics, Faculty of Science, Campus Fuente Nueva, Edificio Mecenas, s/n E-18071, University of Granada, Spain
| | - Razvan Ghinea
- Department of Optics, Faculty of Science, Campus Fuente Nueva, Edificio Mecenas, s/n E-18071, University of Granada, Spain
| | - Rosa Pulgar
- Department of Stomatology, Faculty of Dentistry, Campus de Cartuja s/n E-18071, University of Granada, Spain
| | - Alvaro Della Bona
- Post-Graduate Program in Dentistry, Dental School, University of Passo Fundo, Campus I, Passo Fundo, RS, Brazil
| |
Collapse
|
33
|
Tabatabaian F, Bakhshaei D, Namdari M. Effect of Resin Cement Brand on the Color of Zirconia‐Based Restorations. J Prosthodont 2018; 29:350-355. [DOI: 10.1111/jopr.12953] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/12/2018] [Indexed: 11/30/2022] Open
Affiliation(s)
- Farhad Tabatabaian
- Dental Research Center, Research Institute of Dental Sciences, School of DentistryShahid Beheshti University of Medical Sciences Tehran Iran
- Department of Prosthodontics, School of DentistryShahid Beheshti University of Medical Sciences Tehran Iran
| | | | - Mahshid Namdari
- Department of Community Oral Health, School of DentistryShahid Beheshti University of Medical Sciences Tehran Iran
| |
Collapse
|
34
|
Tabatabaian F. Color Aspect of Monolithic Zirconia Restorations: A Review of the Literature. J Prosthodont 2018; 28:276-287. [DOI: 10.1111/jopr.12906] [Citation(s) in RCA: 75] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/24/2018] [Indexed: 02/02/2023] Open
Affiliation(s)
- Farhad Tabatabaian
- Department of Prosthodontics, School of Dentistry; Shahid Beheshti University of Medical Sciences; Tehran Iran
| |
Collapse
|