1
|
Erdoğdu M, Demirel MG, Mohammadi R, Güntekin N, Ghanbarzadeh Chaleshtori M. Influence of Framework Material and Abutment Configuration on Fatigue Performance in Dental Implant Systems: A Finite Element Analysis. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:1463. [PMID: 39336504 PMCID: PMC11433853 DOI: 10.3390/medicina60091463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2024] [Revised: 08/17/2024] [Accepted: 08/27/2024] [Indexed: 09/30/2024]
Abstract
Background and Objectives: This study uses finite element analysis to evaluate the impact of abutment angulation, types, and framework materials on the stress distribution and fatigue performance of dental implant systems. Materials and Methods: Three-dimensional models of maxillary three-unit fixed implant-supported prostheses were analyzed. Abutments with different angles and types were used. Two different framework materials were used. Conducted on implants, a force of 150 N was applied obliquely, directed from the palatal to the buccal aspect, at a specific angle of 30 degrees. The distribution of stress and fatigue performance were then assessed, considering the types of restoration frameworks used and the angles of the abutments in three distinct locations. The simulation aspect of the research was carried out utilizing Abaqus Software (ABAQUS 2020, Dassault Systems Simulation Corp., Johnston, RT, USA). Results: In all models, fatigue strengths in the premolar region were higher than in the molar region. Maximum stress levels were seen in models with angled implants. In almost all models with the zirconia framework, fatigue performance was slightly lower. Conclusions: According to the findings of this study, it was concluded that the use of metal-framework multi-unit restorations with minimum angulation has significant positive effects on the biomechanics and long-term success of implant treatments.
Collapse
Affiliation(s)
- Meryem Erdoğdu
- Department of Prosthodontics, Faculty of Dentistry, Necmettin Erbakan University, 42090 Konya, Türkiye; (M.G.D.); (N.G.)
| | - Mehmet Gökberkkaan Demirel
- Department of Prosthodontics, Faculty of Dentistry, Necmettin Erbakan University, 42090 Konya, Türkiye; (M.G.D.); (N.G.)
| | - Reza Mohammadi
- Faculty of Dentistry, Necmettin Erbakan University, 42090 Konya, Türkiye;
| | - Neslihan Güntekin
- Department of Prosthodontics, Faculty of Dentistry, Necmettin Erbakan University, 42090 Konya, Türkiye; (M.G.D.); (N.G.)
| | | |
Collapse
|
2
|
Pellegrino G, Zaccheroni Z, Lizio G. Immediate full-arch fixed rehabilitation of a narrow mandible with newly conceived connection system implants: A case report. JOURNAL OF ADVANCED PERIODONTOLOGY & IMPLANT DENTISTRY 2024; 16:64-71. [PMID: 39027210 PMCID: PMC11252157 DOI: 10.34172/japid.2024.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2023] [Accepted: 04/27/2024] [Indexed: 07/20/2024]
Abstract
Rehabilitating thin jaws without reconstructive surgery entails using narrow implants. The proposed treatment adopted an innovative implant system, allowing the mini-screws to be parallel and immediately loaded. A mandible, wearing an overdenture, was functionalized contextually to the residual dental extraction and the placement of six 2.4-mm thick one-piece implants. Low-profile intermediate abutments, the LEMs, able to rotate over the spherical heads of the fixtures, were connected after suturing, oriented, and blocked in a mutual parallel position. The copings, engaging with a tapered juncture of the LEMs, resulted in their alignment to be intraorally wedged together. The provisional superstructure enclosed the copings and was immediately connected to the implants, and the definitive prosthesis was delivered after three months. No clinical signs of peri-implantitis or radiographically evident bone loss were recorded after a two-year follow-up without any prosthetic complication. No cases have been published regarding mini-implants bearing fixed prosthesis rehabilitation.
Collapse
Affiliation(s)
- Gerardo Pellegrino
- Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
| | | | | |
Collapse
|
3
|
Kim MJ, Cho WT, Hwang SH, Bae JH, Bae EB, Shim JS, Kim JE, Jeong CM, Huh JB. A prospective multicenter clinical study on the efficiency of detachable ball- and spring-retained implant prosthesis. J Adv Prosthodont 2023; 15:202-213. [PMID: 37662852 PMCID: PMC10471505 DOI: 10.4047/jap.2023.15.4.202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 08/01/2023] [Accepted: 08/21/2023] [Indexed: 09/05/2023] Open
Abstract
PURPOSE This prospective clinical study was conducted to evaluate the clinical usefulness of the freely detachable zirconia ball- and spring-retained implant prosthesis (BSRP) through a comparative analysis of screw- and cement-retained implant prosthesis (SCRP). MATERIALS AND METHODS A multi-center, randomized, prospective clinical study evaluating the clinical usefulness of the detachable zirconia ball- and spring-retained implant prostheses was conducted. Sixty-four implant prostheses in 64 patients were examined. Periodic observational studies were conducted at 0, 3, 6, and 12 months after delivery of the implant prosthesis. Factors such as implant success rate, marginal bone resorption, periodontal pocket depth, plaque and bleeding index, and prosthetic complications were evaluated, respectively. RESULTS During the 1-year observation period, all implants survived without functional problems and clinical mobility, showing a 100% implant success rate. Marginal bone resorption was significantly higher in the SCRP group than in the BSRP group only at the time of implant prosthesis delivery (P = .043). In all observation periods, periodontal pocket depth was slightly higher in the BSRP group than in the SCRP group, but there was no significant difference (P > .05). The modified plaque index (mPI) scores of both groups were moderate. Higher ratio of a score 2 in modified sulcus bleeding index (mBI) was observed in the BSRP group in the 6- and 12-months observation. CONCLUSION Within the limitations of this study, the newly developed zirconia ball- and spring-retained implant prosthesis could be considered as an applicable and predictable treatment method along with the existing screw- and cement-retained prosthesis.
Collapse
Affiliation(s)
- Min-Jung Kim
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Won-Tak Cho
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Su-Hyun Hwang
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Ji-Hyeon Bae
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Eun-Bin Bae
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
- The Shapiro Family Laboratory of Viral Oncology and Aging Research & Section of Restorative Dentistry, UCLA School of Dentistry, Los Angeles, CA, USA
| | - June-Sung Shim
- Department of Prosthodontics, Yonsei University College of Dentistry, Seoul, Republic of Korea
| | - Jong-Eun Kim
- Department of Prosthodontics, Yonsei University College of Dentistry, Seoul, Republic of Korea
| | - Chang-Mo Jeong
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| |
Collapse
|
4
|
Nair VS, Nachimuthu R. The role of NiTi shape memory alloys in quality of life improvement through medical advancements: A comprehensive review. Proc Inst Mech Eng H 2022; 236:923-950. [PMID: 35486134 DOI: 10.1177/09544119221093460] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The significance of advanced smart materials in recent technological research and advancement is apparent from its extensive use in present day devices and instruments. Of the various smart materials in use today, the fascinating category of shape memory alloys (SMAs) is equipped with the ability to return to a previously memorized shape under certain thermomechanical or magnetic stimuli. The unique property of shape memory effect and superelasticity displayed by these materials along with good biocompatibility and corrosion resistance make them ideal for biomedical applications. The various applications of SMAs in surgical instruments, surgical implants, and assistive and rehabilitative devices have significant effect on the day to day life of people in the present age. Majority of these biomedical devices belong to the orthodontic, orthopedic, or surgical fields. Other remarkable applications of SMAs such as in the production of prostheses and orthoses designed through the biomimetic approach are also highly influential in improving the quality of life. The present paper provides an overview of the various properties of shape memory alloys and their applications in the biomedical field over the years, that have had a significant impact on the realm of medical science.
Collapse
Affiliation(s)
- Viswajith S Nair
- Department of Mechanical Engineering, Amrita School of Engineering, Amrita Vishwa Vidyapeetham, Coimbatore, India
| | - Radhika Nachimuthu
- Department of Mechanical Engineering, Amrita School of Engineering, Amrita Vishwa Vidyapeetham, Coimbatore, India
| |
Collapse
|
5
|
Chae SK, Cho WT, Choi JW, Bae EB, Bae JH, Bae GH, Huh JB. Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar. J Adv Prosthodont 2022; 14:12-21. [PMID: 35284053 PMCID: PMC8891684 DOI: 10.4047/jap.2022.14.1.12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 12/21/2021] [Accepted: 01/04/2022] [Indexed: 11/25/2022] Open
Abstract
PURPOSE The purpose of this study was to investigate changes in retention and wear pattern of Locator® and ADD-TOC attachments on a digital milled bar by performing chewing simulation and repeated insertion/removal of prostheses in fully edentulous models. MATERIALS AND METHODS Locator (Locator®; Zest Anchors Inc., Escondido, CA, USA) was selected as the control group and ADD-TOC (ADD-TOC; PNUAdd Co., Ltd., Busan, Republic of Korea) as the experimental group. A CAD-CAM milled bar was mounted on a master model and 3 threaded holes for connecting a bar attachment was formed using a tap. Locator and ADD-TOC attachments were then attached to the milled bar. Simulated mastication and repeated insertion/removal were performed over 400,000 cyclic loadings and 1,080 insertions/removals, respectively. Wear patterns on deformed attachment were investigated by field emission scanning electron microscopy. RESULTS For the ADD-TOC attachments, chewing simulation and repeated insertion/removal resulted in a mean initial retentive force of 24.43 ± 4.89 N, which were significantly lower than that of the Locator attachment, 34.33 ± 8.25 N (P < .05). Amounts of retention loss relative to baseline for the Locator and ADD-TOC attachments were 21.74 ± 7.07 and 8.98 ± 5.76 N (P < .05). CONCLUSION CAD-CAM milled bar with the ADD-TOC attachment had a lower initial retentive force than the Locator attachment. However, the ADD-TOC attachment might be suitable for long-term use as it showed less deformation and had a higher retentive force after simulated mastication and insertion/removal repetitions.
Collapse
Affiliation(s)
- Sung-Ki Chae
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
- Research and Development Institute, Samwon D.M.P, Yangsan, Republic of Korea
| | - Won-Tak Cho
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
- Research and Development Institute, PNUAdd Co., Ltd., Busan, Republic of Korea
| | - Jae-Won Choi
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Eun-Bin Bae
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Ji-Hyeon Bae
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
- Research and Development Institute, PNUAdd Co., Ltd., Busan, Republic of Korea
| | - Gang-Ho Bae
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
- Research and Development Institute, PNUAdd Co., Ltd., Busan, Republic of Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
- Research and Development Institute, PNUAdd Co., Ltd., Busan, Republic of Korea
| |
Collapse
|
6
|
Influence of an Implant Fixture including a Freely Removable Micro-Locking Implant Prosthesis on Peri-Implant Tissues and Implant Prostheses: A Prospective Clinical Study. J Clin Med 2021; 10:jcm10153321. [PMID: 34362106 PMCID: PMC8348657 DOI: 10.3390/jcm10153321] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 07/08/2021] [Accepted: 07/26/2021] [Indexed: 11/17/2022] Open
Abstract
This prospective study was undertaken to evaluate the clinical usefulness of a newly developed one-piece, screw-free, and micro-locking implant system, which was designed to overcome the shortcomings of the existing implant systems. Thirty-eight patients were recruited and randomly and equally assigned to an experimental group (micro-locking one-piece fixture, MLF; n = 19) or a control group (micro-locking abutment, MLA). Cumulative implant survival rates, marginal bone resorptions, probing depths, plaque indices, bleeding indices, and complications were obtained by using clinical and radiographic findings at 6 months and 12 months after prosthesis placement. Complications that occurred multiple times for single implants were counted. During the 12 month observation period, survival rates were 100% in both groups. No significant intergroup differences were observed for marginal bone resorption, probe depth, or bleeding index. However, mean plaque index was significantly lower in the MLF group at 12 months (p < 0.05). During the 12-month observation period, food impaction (26.3%) was the main complication in the MLF group and screw loosening (5.3%), prosthesis detachment (5.3%), and food impaction (5.3%) were observed in the MLA group. The results of this study suggest that the one-piece micro-locking implant system offers a predictable treatment method.
Collapse
|
7
|
Retrospective Clinical Study of a Freely Removable Implant-Supported Fixed Dental Prosthesis by a Microlocking System. BIOMED RESEARCH INTERNATIONAL 2020; 2020:7929585. [PMID: 33204715 PMCID: PMC7655254 DOI: 10.1155/2020/7929585] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Revised: 10/23/2020] [Accepted: 10/26/2020] [Indexed: 11/17/2022]
Abstract
This retrospective clinical study was conducted to evaluate the clinical usefulness of a freely removable microlocking implant prosthesis (MLP) that was developed to overcome the problems with conventional implant prostheses. A total of 54 patients (male: 31, female: 23) and 100 implant prostheses were included. Patients were divided into three groups such as 6-12 months, 12-18 months, and 18-24 months according to the used period after implant prosthesis delivery, and the patients in each group were recalled for examinations of survival rate, marginal bone resorption, peri-implant soft tissue indices, and complications. The prosthetic complications were analysed by combining the recorded chart data during the periodic checks including the last call for this study. During a 2-year observation period, all the implants showed a 100% survival rate without clinical mobility and functional problems. There was no significant difference in marginal bone resorption, plaque index, and bleeding index over the observation period after implant prosthesis delivery. Probing depth of the 18-24 months group (1.5 ± 0.19 mm) was significantly lower than that of the 6-12 months group (p < 0.05). The main complication was abutment loosening (4%), followed by implant prosthesis fracture (2%) and food impaction (2%) which were recorded. Within the limits of the present study, the implant prostheses with MLP are considered to be an applicable and predictable treatment method.
Collapse
|