1
|
O'Brien C, Naughton D, Honari B, Winning L, Polyzois I. An In Vitro Evaluation of Periotest Implant Stability Measurements Taken on Implant Retained Crowns and Healing Abutments. Clin Exp Dent Res 2024; 10:e910. [PMID: 38881222 PMCID: PMC11180707 DOI: 10.1002/cre2.910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 05/06/2024] [Accepted: 05/18/2024] [Indexed: 06/18/2024] Open
Abstract
OBJECTIVE To assess the reliability of implant stability measurements recorded with the Periotest device and to investigate the differences in values when these measurements were taken on implant retained crowns and healing abutments. MATERIALS AND METHODS Fifty-six implants in eight synthetic bone blocks were used to carry out implant stability measurements using the Periotest device by two different operators. Each block constituted an example of bone of density D1, D2, D3, or D4, and two blocks of each density were used. The healing abutments placed were of a height to allow approximately 6 mm of the implant-abutment complex to be supracrestal and temporary crowns were made to match the dimensions of an average central incisor. Descriptive statistics were used to describe the perio test values (PTVs) at each of the different heights on the implant abutments and implant crowns. Means for each site were calculated and distribution of data assessed using the Kruskal Wallis test. The interclass correlation coefficient (ICC) was used to determine the relationship between the PTVs recorded on the implant abutments and implant crowns. RESULTS The mean PTV (±standard devidation) recorded across all sites was 5.57 ± 11.643 on the implant abutments, and 12.27 ± 11.735 on the temporary crowns. Excellent/good inter-operator ICCs were recorded for the mid-abutment site in all bone blocks D1-D4 (ICC = 0.814, p < 0.001, ICC = 0.922, p < 0.001, ICC = 0.938, p < 0.001, ICC = 776, p < 0.001). For mid crown sites, ICC between operators was excellent/good only for recordings in D2 bone (ICC = 0.897, p < 0.001). CONCLUSIONS Periotest device seems to be able to reliably measure implant stability across all types of bones when the implant stability is assessed at approximately 3 mm coronal to the implant platform for abutments and 4.5 mm for implant supported single crowns.
Collapse
Affiliation(s)
- Cianna O'Brien
- Department of Restorative Dentistry and Periodontology, Dublin Dental University HospitalUniversity of Dublin, Trinity CollegeDublinIreland
| | - David Naughton
- Department of Restorative Dentistry and Periodontology, Dublin Dental University HospitalUniversity of Dublin, Trinity CollegeDublinIreland
| | - Bahman Honari
- Department of Biostatistics, Dublin Dental University HospitalUniversity of Dublin, Trinity CollegeDublinIreland
| | - Lewis Winning
- Department of Restorative Dentistry and Periodontology, Dublin Dental University HospitalUniversity of Dublin, Trinity CollegeDublinIreland
| | - Ioannis Polyzois
- Department of Restorative Dentistry and Periodontology, Dublin Dental University HospitalUniversity of Dublin, Trinity CollegeDublinIreland
| |
Collapse
|
2
|
Shim JS, Kim MY, An SJ, Kang ES, Choi YS. Evaluation of Implant Stability According to Implant Placement Site and Duration in Elderly Patients: A Prospective Multi-Center Cohort Study. J Clin Med 2023; 12:5087. [PMID: 37568490 PMCID: PMC10419881 DOI: 10.3390/jcm12155087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 07/25/2023] [Accepted: 07/31/2023] [Indexed: 08/13/2023] Open
Abstract
The aim of this prospective study is to investigate implant stability and the reliability of different measuring devices according to implant placement site and duration in patients aged over 65 years. The study evaluated 60 implants (diameter: 3.5/4.0/4.5/5.0 mm and length: 8.5/10.0/11.5 mm) in 60 patients aged ≥ 65 years. The implant placement sites were divided into six evenly distributed sections (n = 10), i.e., maxillary right-posterior, A; maxillary anterior, B; maxillary left-posterior, C; mandibular right-posterior, D; mandibular anterior, E; mandibular left-posterior, F. Participants visited the hospital six times: implant surgery, 1V; stitch removal, 2V; 1-month follow-up, 3V; 2-month follow-up, 4V; before final restoration delivery, 5V; and after final restoration delivery, 6V. The implant stability was evaluated with the Osstell Mentor (ISQ), Periotest M (PTV), and Anycheck (IST). The mean values of ISQ, PTV, and IST were analyzed (α = 0.05). ISQ, PTV, and IST results of 4V and 5V were significantly higher than those of 1V (p < 0.05). The lowest ISQ results occurred in the E location at 4V and 5V (p < 0.05). In all mandibular locations, IST results of 6V were significantly higher than those of 1V, 2V, 3V, and 4V (p < 0.05). ISQ results were negatively correlated with PTV and positively correlated with IST, and PTV was negatively correlated with IST. By considering various factors affecting the stability of the implant, it is necessary to determine the appropriate implant load application time. This could help increase the implant success rate in elderly patients. And as a diagnostic device for implant stability and the evaluation of osseointegration in elderly patients, Anycheck was also able to prove its relative reliability compared to Osstell ISQ Mentor and Periotest M.
Collapse
Affiliation(s)
- Ji-Suk Shim
- Department of Dentistry, Korea University Guro Hospital, Seoul 08308, Republic of Korea
| | - Moon-Young Kim
- Department of Oral and Maxillofacial Surgery, College of Dentistry, Dankook University, Cheonan 31116, Republic of Korea
| | - Se-Jun An
- Department of Prosthodontics, College of Dentistry, Dankook University, Cheonan 31116, Republic of Korea
| | - Eun-Sung Kang
- Department of Oral and Maxillofacial Surgery, College of Dentistry, Dankook University, Cheonan 31116, Republic of Korea
| | - Yu-Sung Choi
- Department of Prosthodontics, College of Dentistry, Dankook University, Cheonan 31116, Republic of Korea
| |
Collapse
|
3
|
D'Orto B, Chiavenna C, Leone R, Longoni M, Nagni M, Capparè P. Marginal Bone Loss Compared in Internal and External Implant Connections: Retrospective Clinical Study at 6-Years Follow-Up. Biomedicines 2023; 11:biomedicines11041128. [PMID: 37189746 DOI: 10.3390/biomedicines11041128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 03/29/2023] [Accepted: 03/31/2023] [Indexed: 05/17/2023] Open
Abstract
The aim of this study was to assess and compare the marginal bone loss between two different categories of implants (Winsix, Biosafin, Ancona, Italy) having the same diameter and belonging to the Torque Type® (TT®) line, in the internal hexagon version (TTi, Group A) and in the external hexagon configuration (TTx, Group B). Patients with one or more straight implants (insertion parallel to the occlusal plane) in the molar and premolar regions in association with tooth extraction at least 4 months prior to implant insertion, who have a fixture diameter of 3.8 mm, who followed up for at least 6 years, and whose radiographic records were available were enrolled in this study. Depending on implant connections (externally or internally), the sample was divided into groups A and B. For externally connected implants (66), the marginal resorption was 1.1 ± 0.17 mm. The subgroup of single and bridge implants showed no statistically significant differences with a marginal bone resorption of 1.07 ± 0.15 mm and 1.1 ± 0.17 mm, respectively. Internally connected implants (69) showed an overall marginal resorption of 0.91 ± 0.17 mm, while the subgroup of single and bridge implants showed resorption of 0.90 ± 0.19 mm and 0.90 ± 0.17 mm, respectively, with no statistically significant differences. According to the obtained results, internally connected implants showed less marginal bone resorption than externally connected implants.
Collapse
Affiliation(s)
- Bianca D'Orto
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute San Raffaele University, 20132 Milan, Italy
| | - Carlo Chiavenna
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute San Raffaele University, 20132 Milan, Italy
| | - Renato Leone
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, Division of Fixed Prosthodontics, "Federico II" University of Naples, 80100 Naples, Italy
| | - Martina Longoni
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute San Raffaele University, 20132 Milan, Italy
| | - Matteo Nagni
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute San Raffaele University, 20132 Milan, Italy
| | - Paolo Capparè
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute San Raffaele University, 20132 Milan, Italy
| |
Collapse
|
4
|
Parvini P, Müller KM, Cafferata EA, Schwarz F, Obreja K. Immediate versus delayed implant placement in the esthetic zone: a prospective 3D volumetric assessment of peri-implant tissue stability. Int J Implant Dent 2022; 8:58. [PMID: 36434348 PMCID: PMC9700553 DOI: 10.1186/s40729-022-00457-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Accepted: 11/12/2022] [Indexed: 11/27/2022] Open
Abstract
PURPOSE To evaluate the volumetric stability of peri-implant soft and hard tissue prospectively, this study compared immediate versus delayed implants placed in the anterior esthetic region. METHODS This non-randomized controlled clinical study included 25 patients, who received an immediate (type 1) or a delayed (type 4) implant placement for the replacement of a single anterior tooth. The anterior maxillae were intraorally scanned at three timepoints: before surgery (S0), 6 months (S1), and 12 months (S2) after surgery. A specific region of interest (ROI), divided into marginal and apical regions, was determined and superimposed for volumetric changes analysis. At 6 and 12 months, the probing depth (PD), bleeding/suppuration on probing (BOP/SUP), modified plaque index (PI), keratinized mucosa (KM) width, mucosal recession (MR), and implant stability (PTV) by means of periotest were recorded. RESULTS Between S0-S2, tissue surrounding immediate implants was reduced in 0.37 ± 0.31 mm, whereas delayed implants gained 0.84 ± 0.57 mm mean tissue volume. Peri-implant tissue loss at type 1 implants occurred primarily in the marginal section of the ROI (0.42 ± 0.31 mm), whereas tissue gain at type 4 implants occurred mainly in the apical section (0.83 ± 0.51 mm). These values were significantly different between both groups for the entire ROI (p = 0.0452) and the marginal region (p = 0.0274). In addition, the mean buccal KM width around type 1 implants was significantly wider in comparison with the type 4 implants group after 12 months (p = 0.046). There were no significant differences between groups regarding PD, BOP/SUP, or PTV. CONCLUSIONS The results suggest that type 1 implants placed in the esthetic region experience more tissue loss than type 4 implants, thus marginal tissue remodeling should be considered for planning immediate implants placement in the anterior maxillae.
Collapse
Affiliation(s)
- Puria Parvini
- grid.7839.50000 0004 1936 9721Department of Oral Surgery and Implantology, Goethe University, Carolinum, Frankfurt Am Main, Germany
| | - Katharina Melissa Müller
- grid.7839.50000 0004 1936 9721Department of Oral Surgery and Implantology, Goethe University, Carolinum, Frankfurt Am Main, Germany
| | - Emilio A. Cafferata
- grid.7839.50000 0004 1936 9721Department of Oral Surgery and Implantology, Goethe University, Carolinum, Frankfurt Am Main, Germany ,grid.430666.10000 0000 9972 9272Department of Periodontology, School of Dentistry, Universidad Científica del Sur, Lima, Peru
| | - Frank Schwarz
- grid.7839.50000 0004 1936 9721Department of Oral Surgery and Implantology, Goethe University, Carolinum, Frankfurt Am Main, Germany
| | - Karina Obreja
- grid.7839.50000 0004 1936 9721Department of Oral Surgery and Implantology, Goethe University, Carolinum, Frankfurt Am Main, Germany
| |
Collapse
|
5
|
Fouda K, Fahmy A, Aziz K, Aal MA, Naguib A, Nabi NA. Implant Stability Changes for a Single Implant Mandibular Overdenture. Eur J Dent 2021; 16:619-626. [PMID: 34879396 PMCID: PMC9507585 DOI: 10.1055/s-0041-1736416] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/05/2022] Open
Abstract
Objectives
To compare the changes in implant stability for the nonsubmerged and submerged protocols for a single-implant retained mandibular overdenture using Cendres and Metaux Locator attachment throughout a 24-month follow-up.
Materials and Methods
Eighty edentulous patients who were seeking to install a single implant in the midline of the completely edentulous mandible. At the day of implant installation, patients were randomized into two groups using sealed envelopes: the nonsubmerged and submerged groups. After 3 months of healing period, randomization using sealed envelopes was performed and patients were randomized to receive the Cendres and Metaux Locator attachment. The periotest readings were recorded using the Periotest M device, every 3 months for the first year and annually in the second year. The scope of this clinical trial focused only on results of the Cendres and Metaux attachment.
Statistical Analysis
The Mann–Whitney
U
-test was used for comparison between study groups for independent samples. Two-sided
p
-values less than 0.05 were considered statistically significant.
Results
There was no statistically significant difference between the mean periotest readings of both groups throughout the 24-month follow-up. Both groups showed an improvement in mean periotest readings with the submerged group tending to show greater stability at 6, 12, and 24-month follow-ups.
Conclusions
The nonsubmerged and the submerged healing protocols resulted in reliable periotest readings with the submerged group showing greater improvement than the nonsubmerged, although this improvement is nonsignificant when using the Cendres and Metaux attachment for a single mandibular overdenture.
Collapse
Affiliation(s)
- Karim Fouda
- Department of Prosthodontics, Faculty of Dentistry, Cairo University, Cairo, Egypt
| | - Ahmed Fahmy
- Department of Prosthodontics, Faculty of Dentistry, Cairo University, Cairo, Egypt
| | - Khaled Aziz
- Department of Prosthodontics, Faculty of Dentistry, Cairo University, Cairo, Egypt
| | - Marwa Abdel Aal
- Department of Prosthodontics, Faculty of Dentistry, Cairo University, Cairo, Egypt
| | - Amr Naguib
- Department of Prosthodontics, Faculty of Dentistry, Cairo University, Cairo, Egypt
| | - Nouran Abdel Nabi
- Department of Prosthodontics, Faculty of Dentistry, Cairo University, Cairo, Egypt
| |
Collapse
|
6
|
Implant Stability Changes for Nonsubmerged and Submerged Protocols for a Single Implant Mandibular Overdenture Using Ball Attachment. Int J Dent 2021; 2021:8269197. [PMID: 34594381 PMCID: PMC8478597 DOI: 10.1155/2021/8269197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Accepted: 09/08/2021] [Indexed: 12/02/2022] Open
Abstract
Objectives To compare the changes in implant stability for the nonsubmerged (NS) and submerged (S) protocols for the single implant retained mandibular overdenture using ball attachment throughout a 24-month follow-up. Materials and Methods Eighty completely edentulous patients were seeking to improve retention of their lower complete denture by installing a single implant in the midline of the completely edentulous mandible. At the day of implant installation, patients were randomized into 2 groups using sealed envelopes: the nonsubmerged (NS) and submerged (S) group. After a 3-month healing period, all patients were randomized using sealed envelopes into ball attachment and CM-LOC attachment. The Periotest readings (PTV) was recorded using the Periotest M device and was recorded every 3 months for the first year and then annually in the second year. The scope of this clinical trial focused only on results of the ball attachment. The Mann–Whitney U test was used for comparison between study groups for independent samples. Two-sided p values less than 0.05 was considered statistically significant. Results There was no statistically significant difference in the mean change in PTV reading between the NS and S group at the different follow-up intervals. Initially, at the day of pickup (baseline) and 3-month follow-up, the mean PTV reading for the NS was greater than that of the S group (−4.471 ± 1.489, −4.391 ± 1.4727 (p=0.913)), while the S group has shown a greater improvement in PTV than the NS group after 6-month follow-up and continued throughout the 24-month follow-up (−5.730 ± 1.7804, −50855 ± 1.2581 (p=1)). Conclusion Both the nonsubmerged and the submerged healing protocol have shown reliable Periotest readings using ball attachment for a single implant retained overdenture. The submerged group has resulted in a greater improvement in Periotest readings after the 12- and 24-month follow-up period when compared to the nonsubmerged group although this improvement was not statistically significant.
Collapse
|
7
|
The Effects of Smoking Cigarettes on Immediate Dental Implant Stability—A Prospective Case Series Study. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app11010027] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Background: Smoking tobacco significantly affects the biology of periodontal tissues and contributes to the increased risk of peri-implant diseases. The aim of the study was to investigate whether smoking cigarettes affects the primary and secondary stability of maxillary dental implants, inserted into fresh sockets immediately after extraction. Methods: The study was conducted on 164 patients between the ages of 27–71 years old. 67 individuals smoked more than 20 cigarettes daily and 97 were non-smokers. 190 immediate implants were inserted in the maxilla. Immediate implantations were performed with simultaneous augmentation of the socket with xenogenic bone grafting material. In the posterior region, implants were inserted into the palatal alveolus. The stability of the implants was measured using Insertion Torque Value (ITV) and two types of devices: Periotest (PT) and Osstell (ISQ). Marginal bone loss was evaluated on cone beam computed tomography scans. Results: In an aesthetic area, the PT values at 6 months post-implantation were higher for smokers than non-smokers (p < 0.05), respectively. The ISQ values were significantly lower in smokers compared to non-smokers at 6 months post-implantation (p = 0.0226), respectively. In the posterior region PT values were higher in smokers both on the day of implantation (p = 0.0179), 6 months after surgery (p = 0.0003) as well as 24 months after surgery (p < 0.0001), as compared to non-smokers, respectively. Smokers revealed lower ISQ values than non-smokers (p = 0.0047) on the day of implantation, as well as 6 months after implantation (p = 0.0002), respectively. There were no significant differences in marginal bone loss after 18 months of loading between smokers and non-smokers in the aesthetic, as well as posterior regions (p > 0.05). ITV measurements were lower in smokers than non-smokers in the aesthetic (16.3 vs. 17.5 Ncm) and posterior area (16.8 vs. 17.9 Ncm). Conclusions: This study indicate that smoking cigarettes has a negative effect on the stability of immediate implants in the maxilla. Primary stability of immediate implants may be lower in the posterior area of the maxilla in smokers when compared to non-smokers, which may eliminate smokers from immediate implants in this region. Secondary stability of immediate implants may be lower in both the aesthetic and posterior areas in smokers compared to non-smokers, which may encourage the postponement of final crowns delivery at 6 months post op and the extension of the occlusaly temporary crowns use in some smoker cases.
Collapse
|
8
|
Karakaya M, Demirbaş AE. Effect of low-level laser therapy on osseointegration of titanium dental implants in ovariectomized rabbits: biomechanics and micro-CT analysis. Int J Implant Dent 2020; 6:61. [PMID: 33043397 PMCID: PMC7548265 DOI: 10.1186/s40729-020-00257-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2020] [Accepted: 08/31/2020] [Indexed: 11/10/2022] Open
Abstract
PURPOSE The primary aim of this study is to assess, in an animal model, whether biostimulation of osteoporotic bone with low-level laser therapy improves the osseointegration of dental implants. MATERIAL AND METHODS Twenty-two female rabbits were randomly divided into two groups: sham-ovariectomy and bilateral-ovariectomy. Laser therapy was applied to the implants placed in the right tibial bones and was not applied to implants placed in the left tibial bones. The periotest device was used for the stability test. Periotest values were recorded after the implantation (T0) and when the animals were euthanized (T1). The removal torque test and micro-computed tomography examination were evaluated. RESULTS As a result of removal torque, the mean of ovariectomy-laser group (56.1 ± 5.1 Ncm) was higher than sham-ovariectomy group (55.4 ± 18.5 Ncm) (p = 0.9). In periotest analysis, a significant difference was found between the values of T1 and T0 in all groups, except sham-ovariectomy group (p < 0.05); and the highest difference was found in the ovariectomy-laser group. Micro-CT examination demonstrated that ovariectomy-laser group showed an increase of implant-bone contact when compared with ovariectomy (p < 0.05). CONCLUSIONS The values obtained from biomechanical tests and micro-CT in the ovariectomy-laser group were significantly higher than the ovariectomy group and achieved the values in the healthy bone.
Collapse
Affiliation(s)
- Mustafa Karakaya
- Sancaktepe Oral and Dental Health Hospital, Department of Oral and Maxillofacial Surgery, Ministry of Health, İstanbul, Turkey.
| | - Ahmet Emin Demirbaş
- Department of Oral and Maxillofacial Surgery, Erciyes University Faculty of Dentistry, Melikgazi, Kayseri, Turkey
| |
Collapse
|
9
|
H H, G W, E H. The clinical significance of implant stability quotient (ISQ) measurements: A literature review. J Oral Biol Craniofac Res 2020; 10:629-638. [PMID: 32983857 DOI: 10.1016/j.jobcr.2020.07.004] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 06/22/2020] [Accepted: 07/13/2020] [Indexed: 10/23/2022] Open
Abstract
Implant stability quotients (ISQ values) are obtained in dental clinical practice on a non-invasive basis by resonance frequency measurement rapidly after surgical placement of implants. The ISQ-values are used as indicator for mechanical implant stability, and are believed to have predictive power for clinical outcome. It is the aim of this review to provide a synopsis of all factors described in the literature that influence ISQ measurements by performing an exhaustive literature review; moreover, this review aims at elucidating the key factors relevant for a rapid clinical predictive assessment. We searched systematically and exhaustively all major databases for publications relating to ISQ measurement methodology and for ISQ-influencing factor analyses. The reports identified were ordered in experimental (preclinical) studies and in clinical publications. We were able to identify 13 basic factors influencing ISQ-measurements. Among these, local bone quality, playing a key role in such measurements, was subdivided in four specific subfactors; thus a total of 17 individual factors was identified and reported to influence ISQ-measurements. A comprehensive list of these factors is provided in Table-form. A critical analysis points out that only 6 of these factors are of a sound predictive power useful for a rapid clinical assessment; and only two of these factors appear to have a well-documented scientific basis.
Collapse
Affiliation(s)
- Huang H
- Department of Oral Implantology and Prosthetic Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije University Amsterdam, Gustav Mahlerlaan, 3004, 1081LA Amsterdam, Nord-Holland, the Netherlands.,Department of Osteoporosis, Inselspital Bern University Hospital, Freiburgstrasse 3, CH-3010, Bern, Switzerland
| | - Wu G
- Department of Oral Implantology and Prosthetic Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije University Amsterdam, Gustav Mahlerlaan, 3004, 1081LA Amsterdam, Nord-Holland, the Netherlands
| | - Hunziker E
- Department of Osteoporosis, Inselspital Bern University Hospital, Freiburgstrasse 3, CH-3010, Bern, Switzerland.,Departments of Osteoporosis and Orthopaedic Surgery, Inselspital Bern University Hospital, Freiburgstrasse 3, CH-3010, Bern, Switzerland
| |
Collapse
|