Deshmukh P, Dhatrak P. Evaluating the Feasibility of Short Dental Implants as Alternatives to Long Dental Implants in Mandibular Bone: A Finite Element Study. J Biomed Mater Res B Appl Biomater 2024; 112:e35481. [PMID: 39213170 DOI: 10.1002/jbm.b.35481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2024] [Revised: 08/01/2024] [Accepted: 08/14/2024] [Indexed: 09/04/2024]
Abstract
This study uses finite element analysis to investigate the potential application of shorter dental implants as a substitute for longer implants in the lower jaw (mandible). FEA allows the evaluation of the stress patterns around the implant-bone interface, a critical factor for successful osseointegration. Ten models were generated, encompassing five long (L1-L5) and five short implant models (S1-S5) with variations in diameter and length. Hypermesh software was utilized to meticulously prepare the FEA models, ensuring accurate mesh generation. The FEA simulations were conducted under four distinct loading scenarios (100 N occlusal load, 40 N lateral load, 100 N oblique at 30°, and 100 N oblique at 45°) to realistically mimic the forces exerted during biting, using an ABAQUS CAE solver. The results revealed that the von Mises stress generated within the short implant models was demonstrably lower compared to their long implants. Additionally, a significant drop in stress was observed with increasing the diameter of the short implants, to a certain diameter range. These findings suggest the potential for successful substitution of long implant model L4 with short implant model S4 due to the demonstrably lower stress values achieved. Furthermore, the data indicates the possibility of utilizing short implant models S3 and S5 as alternatives to long implant models L3 and L5, respectively. These observations hold significant promise for evaluating the feasibility of replacing long implants with shorter variants, potentially leading to a reduction in implant-related failures.
Collapse
Affiliation(s)
- Prathamesh Deshmukh
- Department of Mechanical Engineering, Dr. Vishwanath Karad MIT World Peace University, Pune, India
| | - Pankaj Dhatrak
- Department of Mechanical Engineering, Dr. Vishwanath Karad MIT World Peace University, Pune, India
| |
Collapse
|
2
|
Anniwaer A, Muhetaer A, Yin Z, Zhu J, Jin C, Huang C. Influence of prosthetic index structures and implant materials on stress distribution in implant restorations: a three-dimensional finite element analysis. BMC Oral Health 2024; 24:901. [PMID: 39107754 PMCID: PMC11304626 DOI: 10.1186/s12903-024-04680-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2024] [Accepted: 07/29/2024] [Indexed: 08/10/2024] Open
Abstract
BACKGROUND Mechanical complications affect the stability of implant restorations and are a key concern for clinicians, especially with the frequent introduction of new implant designs featuring various structures and materials. This study evaluated the effect of different prosthetic index structure types and implant materials on the stress distribution of implant restorations using both in silico and in vitro methods. METHODS Four finite element analysis (FEA) models of implant restorations were created, incorporating two prosthetic index structures (cross-fit (CF) and torc-fit (TF)) and two implant materials (titanium and titanium-zirconium). A static load was applied to each group. An in vitro study using digital image correlation (DIC) with a research scenario identical to that of the FEA was conducted for validation. The primary strain, sensitivity index, and equivalent von Mises stress were used to evaluate the outcomes. RESULTS Changing the implant material from titanium to titanium-zirconium did not significantly affect the stress distribution or maximum stress value of other components, except for the implant itself. In the CF group, implants with a lower elastic modulus increased the stress on the screw. The TF group showed better stress distribution on the abutment and a lower stress value on the screw. The TF group demonstrated similar sensitivity for all components. DIC analysis revealed significant differences between TF-TiZr and CF-Ti in terms of the maximum (P < 0.001) and minimum principal strains (P < 0.05) on the implants and the minimum principal strains on the investment materials in both groups (P < 0.001). CONCLUSIONS Changes in the implant material significantly affected the maximum stress of the implant. The TF group exhibited better structural integrity and reliability.
Collapse
Affiliation(s)
- Annikaer Anniwaer
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, #237 Luoyu Road, Hongshan District, Wuhan, 430079, China
| | - Aihemaiti Muhetaer
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, #237 Luoyu Road, Hongshan District, Wuhan, 430079, China
| | - Zhengrong Yin
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, #237 Luoyu Road, Hongshan District, Wuhan, 430079, China
| | - Jiakang Zhu
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, #237 Luoyu Road, Hongshan District, Wuhan, 430079, China
| | - Chunxiao Jin
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, #237 Luoyu Road, Hongshan District, Wuhan, 430079, China
| | - Cui Huang
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, #237 Luoyu Road, Hongshan District, Wuhan, 430079, China.
| |
Collapse
|
3
|
Zhang C, Wang Y. Biomechanical Analysis of Axial Gradient Porous Dental Implants: A Finite Element Analysis. J Funct Biomater 2023; 14:557. [PMID: 38132811 PMCID: PMC10743419 DOI: 10.3390/jfb14120557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 11/17/2023] [Accepted: 11/20/2023] [Indexed: 12/23/2023] Open
Abstract
The porous structure can reduce the elastic modulus of a dental implant and better approximate the elastic characteristics of the material to the alveolar bone. Therefore, it has the potential to alleviate bone stress shielding around the implant. However, natural bone is heterogeneous, and, thus, introducing a porous structure may produce pathological bone stress. Herein, we designed a porous implant with axial gradient variation in porosity to alleviate stress shielding in the cancellous bone while controlling the peak stress value in the cortical bone margin region. The biomechanical distribution characteristics of axial gradient porous implants were studied using a finite element method. The analysis showed that a porous implant with an axial gradient variation in porosity ranging from 55% to 75% was the best structure. Under vertical and oblique loads, the proportion of the area with a stress value within the optimal stress interval at the bone-implant interface (BII) was 40.34% and 34.57%, respectively, which was 99% and 65% higher compared with that of the non-porous implant in the control group. Moreover, the maximum equivalent stress value in the implant with this pore parameter was 64.4 MPa, which was less than 1/7 of its theoretical yield strength. Axial gradient porous implants meet the strength requirements for bone implant applications. They can alleviate stress shielding in cancellous bone without increasing the stress concentration in the cortical bone margin, thereby optimizing the stress distribution pattern at the BII.
Collapse
Affiliation(s)
- Chunyu Zhang
- Xiangya Stomatological Hospital, Central South University, No. 72 Xiangya Street, Kaifu District, Changsha 410008, China;
- Xiangya School of Stomatology, Central South University, No. 72 Xiangya Street, Kaifu District, Changsha 410008, China
- Hunan 3D Printing Engineering Research Center of Oral Care, No. 64 Xiangya Street, Kaifu District, Changsha 410008, China
| | - Yuehong Wang
- Xiangya Stomatological Hospital, Central South University, No. 72 Xiangya Street, Kaifu District, Changsha 410008, China;
- Xiangya School of Stomatology, Central South University, No. 72 Xiangya Street, Kaifu District, Changsha 410008, China
- Hunan 3D Printing Engineering Research Center of Oral Care, No. 64 Xiangya Street, Kaifu District, Changsha 410008, China
| |
Collapse
|
4
|
Nie H, Tang Y, Yang Y, Wu W, Zhou W, Liu Z. Influence of a new abutment design concept on the biomechanics of peri-implant bone, implant components, and microgap formation: a finite element analysis. BMC Oral Health 2023; 23:277. [PMID: 37170117 PMCID: PMC10176806 DOI: 10.1186/s12903-023-02989-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 04/25/2023] [Indexed: 05/13/2023] Open
Abstract
BACKGROUND A new two-piece abutment design consisting of an upper prosthetic component and tissue-level base has been introduced; however, the biomechanical behavior of such a design has not been documented. This study aimed to investigate the effect of a two-piece abutment design on the stress in the implant components and surrounding bone, as well as its influence on microgap formation. METHODS To simulate the implant models in the mandibular left first molar area, we established nine experimental groups that included three bone qualities (type II, III, and IV) and three implant-abutment designs (internal bone level, tissue level, and a two-piece design). After the screw was preloaded, the maximum occlusal (600 N) and masticatory (225 N) forces were established. Finite element analysis was performed to analyze the maximum and minimum principal stresses on the peri-implant bone; the von Mises stresses in the implants, abutments, bases, and screws, and the microgaps at the implant-abutment, implant-base, and base-abutment interfaces. RESULTS For all three loading methods, the two-piece abutment design and bone-level connection exhibited similarities in the maximum and minimum principal stresses in the peri-implant bone. The von Mises stresses in both screws and bases were greater for the two-piece design than for the other connection types. The smallest microgap was detected in the tissue-level connection; the largest was observed at the implant-base interface in the two-piece design. CONCLUSIONS The present study found no evidence that the abutment design exerts a significant effect on peri-implant bone stress. However, the mechanical effects associated with the base and screws should be noted when using a two-piece abutment design. The two-piece abutment design also had no advantage in eliminating the microgap.
Collapse
Affiliation(s)
- Huimin Nie
- Department of Implant Dentistry, Binzhou Medical University Affiliated Yantai Stomatological Hospital, No. 19, Beima Road, Zhifu District, Yantai, 264000, China
| | - Yantai Tang
- Department of Implant Dentistry, Binzhou Medical University Affiliated Yantai Stomatological Hospital, No. 19, Beima Road, Zhifu District, Yantai, 264000, China
| | - Yan Yang
- Department of Implant Dentistry, Binzhou Medical University Affiliated Yantai Stomatological Hospital, No. 19, Beima Road, Zhifu District, Yantai, 264000, China
| | - Weijie Wu
- University of Science and Technology Beijing, Beijing, 100000, China
| | - Wenjuan Zhou
- Department of Implant Dentistry, Binzhou Medical University Affiliated Yantai Stomatological Hospital, No. 19, Beima Road, Zhifu District, Yantai, 264000, China.
| | - Zhonghao Liu
- Department of Implant Dentistry, Binzhou Medical University Affiliated Yantai Stomatological Hospital, No. 19, Beima Road, Zhifu District, Yantai, 264000, China
| |
Collapse
|
5
|
Lemos CAA, de Oliveira AS, Faé DS, Oliveira HFFE, Del Rei Daltro Rosa CD, Bento VAA, Verri FR, Pellizzer EP. Do dental implants placed in patients with osteoporosis have higher risks of failure and marginal bone loss compared to those in healthy patients? A systematic review with meta-analysis. Clin Oral Investig 2023:10.1007/s00784-023-05005-2. [PMID: 37043030 DOI: 10.1007/s00784-023-05005-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Accepted: 03/28/2023] [Indexed: 04/13/2023]
Abstract
PURPOSE This systematic review and meta-analysis aimed to compare the dental implant survival rate and marginal bone loss between patients with and without osteoporosis. MATERIALS AND METHODS This systematic review was registered in PROSPERO (CRD42022356377). A systematic search was performed using five databases: MEDLINE/PubMed, Web of Science, Scopus, Embase, and ProQuest for articles published up to July 2022. Additional searches in ClinicalTrials.gov and the reference lists of included studies were performed. The eligibility criteria comprised observational studies with a direct comparison between patients with and without osteoporosis, with a minimum follow-up of 1 year and 10 implants placed in each group, which consider data analysis based on implant level, without restrictions on period or language of publication. The meta-analysis was performed using RevMan 5.4 program. Risk of bias analysis of the included studies was performed using the Newcastle-Ottawa scale (NOS). RESULTS Twelve studies met the eligibility criteria, totaling 1132 patients with a mean age range from 54 to 76.6 years. Most of the included patients were women (73.6%). A total of 3505 implants were evaluated-983 in patients with osteoporosis and 2522 in patients without osteoporosis. The meta-analysis indicated no difference in implant survival rates between patients with and without osteoporosis (OR, 1.78; 95% confidence interval [CI], 0.86-3.70; P = 0.12). However, significant bone loss was observed around dental implants placed in patients with osteoporosis (SMD, 0.71 mm; 95% CI, 0.06-0.87 mm). The NOS indicated a low risk of bias in the studies included. However, the certainty of the evidence was classified as very low and low for implant survival rates and bone loss, respectively. CONCLUSION According to the limitations of the present review, the data suggest that dental implants are a viable treatment option for the rehabilitation of patients with osteoporosis. However, clinical care by professionals is necessary to ensure the maintenance of peri-implant bone stability, as these patients may be susceptible to increased bone loss.
Collapse
Affiliation(s)
- Cleidiel Aparecido Araujo Lemos
- Department of Dentistry, Federal University of Juiz de Fora (UFJF), Campus Avançado Governador Valadares, Governador Valadares, Minas Gerais, Brazil.
| | - Andreza Soares de Oliveira
- Department of Dentistry, Federal University of Juiz de Fora (UFJF), Campus Avançado Governador Valadares, Governador Valadares, Minas Gerais, Brazil
| | - Daniele Sorgatto Faé
- Postgraduate Program in Applied Health Sciences (PPGCAS), Federal University of Juiz de Fora (UFJF), Campus Avançado Governador Valadares, Governador Valadares, Minas Gerais, Brazil
| | | | - Cleber Davi Del Rei Daltro Rosa
- Department of Dental Materials and Prosthodontics, Aracatuba Dental School, UNESP-Univ Estadual Paulista, Araçatuba, SP, Brazil
| | - Victor Augusto Alves Bento
- Department of Dental Materials and Prosthodontics, Aracatuba Dental School, UNESP-Univ Estadual Paulista, Araçatuba, SP, Brazil
| | - Fellippo Ramos Verri
- Department of Dental Materials and Prosthodontics, Aracatuba Dental School, UNESP-Univ Estadual Paulista, Araçatuba, SP, Brazil
| | - Eduardo Piza Pellizzer
- Department of Dental Materials and Prosthodontics, Aracatuba Dental School, UNESP-Univ Estadual Paulista, Araçatuba, SP, Brazil
| |
Collapse
|
6
|
Zhang C, Zeng C, Wang Z, Zeng T, Wang Y. Optimization of stress distribution of bone-implant interface (BII). BIOMATERIALS ADVANCES 2023; 147:213342. [PMID: 36841109 DOI: 10.1016/j.bioadv.2023.213342] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 02/03/2023] [Accepted: 02/10/2023] [Indexed: 02/17/2023]
Abstract
Many studies have found that the threshold of occlusal force tolerated by titanium-based implants is significantly lower than that of natural teeth due to differences in biomechanical mechanisms. Therefore, implants are considered to be susceptible to occlusal trauma. In clinical practice, many implants have shown satisfactory biocompatibility, but the balance between biomechanics and biofunction remains a huge clinical challenge. This paper comprehensively analyzes and summarizes various stress distribution optimization methods to explore strategies for improving the resistance of the implants to adverse stress. Improving stress resistance reduces occlusal trauma and shortens the gap between implants and natural teeth in occlusal function. The study found that: 1) specific implant-abutment connection design can change the force transfer efficiency and force conduction direction of the load at the BII; 2) reasonable implant surface structure and morphological character design can promote osseointegration, maintain alveolar bone height, and reduce the maximum effective stress at the BII; and 3) the elastic modulus of implants matched to surrounding bone tissue can reduce the stress shielding, resulting in a more uniform stress distribution at the BII. This study concluded that the core BII stress distribution optimization lies in increasing the stress distribution area and reducing the local stress peak value at the BII. This improves the biomechanical adaptability of the implants, increasing their long-term survival rate.
Collapse
Affiliation(s)
- Chunyu Zhang
- Xiangya Stomatological Hospital, Central South University, No. 72 Xiangya Street, Kaifu District, Changsha, 410008, Hunan, China; Xiangya School of Stomatology, Central South University, No. 72 Xiangya Street, Kaifu District, Changsha, 410008, Hunan, China; Hunan 3D Printing Engineering Research Center of Oral Care, No. 64 Xiangya Street, Kaifu District, Changsha, 410008, Hunan, China.
| | - Chunyu Zeng
- Xiangya Stomatological Hospital, Central South University, No. 72 Xiangya Street, Kaifu District, Changsha, 410008, Hunan, China; Xiangya School of Stomatology, Central South University, No. 72 Xiangya Street, Kaifu District, Changsha, 410008, Hunan, China; Hunan 3D Printing Engineering Research Center of Oral Care, No. 64 Xiangya Street, Kaifu District, Changsha, 410008, Hunan, China
| | - Zhefu Wang
- Xiangya Stomatological Hospital, Central South University, No. 72 Xiangya Street, Kaifu District, Changsha, 410008, Hunan, China; Xiangya School of Stomatology, Central South University, No. 72 Xiangya Street, Kaifu District, Changsha, 410008, Hunan, China; Hunan 3D Printing Engineering Research Center of Oral Care, No. 64 Xiangya Street, Kaifu District, Changsha, 410008, Hunan, China
| | - Ting Zeng
- Xiangya Stomatological Hospital, Central South University, No. 72 Xiangya Street, Kaifu District, Changsha, 410008, Hunan, China; Xiangya School of Stomatology, Central South University, No. 72 Xiangya Street, Kaifu District, Changsha, 410008, Hunan, China; Hunan 3D Printing Engineering Research Center of Oral Care, No. 64 Xiangya Street, Kaifu District, Changsha, 410008, Hunan, China
| | - Yuehong Wang
- Xiangya Stomatological Hospital, Central South University, No. 72 Xiangya Street, Kaifu District, Changsha, 410008, Hunan, China; Xiangya School of Stomatology, Central South University, No. 72 Xiangya Street, Kaifu District, Changsha, 410008, Hunan, China; Hunan 3D Printing Engineering Research Center of Oral Care, No. 64 Xiangya Street, Kaifu District, Changsha, 410008, Hunan, China.
| |
Collapse
|
7
|
Lopes GDRS, de Matos JDM, Queiroz DA, Tribst JPM, Ramos NDC, Rocha MG, Barbosa AB, Bottino MA, Borges ALS, Nishioka RS. Influence of Abutment Design on Biomechanical Behavior to Support a Screw-Retained 3-Unit Fixed Partial Denture. MATERIALS (BASEL, SWITZERLAND) 2022; 15:6235. [PMID: 36143553 PMCID: PMC9504379 DOI: 10.3390/ma15186235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 08/16/2022] [Accepted: 09/05/2022] [Indexed: 06/16/2023]
Abstract
This study aimed to evaluate the biomechanical behavior of Morse taper implants using different abutments (CMN abutment [(CMN Group] and miniconical abutments [MC Group]), indicated to support a screw-retained 3-unit fixed partial denture. For the in vitro test, polyurethane blocks were fabricated for both groups (n = 10) and received three implants in the "offset" configuration and their respective abutments (CMN or MC) with a 3-unit fixed partial denture. Four strain gauges were bonded to the surface of each block. For the finite element analysis, 3D models of both groups were created and exported to the analysis software to perform static structural analysis. All structures were considered homogeneous, isotropic, and elastic. The contacts were considered non-linear with a friction coefficient of 0.3 between metallic structures and considered bonded between the implant and substrate. An axial load of 300 N was applied in three points (A, B, and C) for both methods. The microstrain and the maximum principal stress were considered as analysis criteria. The obtained data were submitted to the Mann-Whitney, Kruskal-Wallis, and Dunn's multiple comparison test (α = 5%). The results obtained by strain gauge showed no statistical difference (p = 0.879) between the CMN (645.3 ± 309.2 με) and MC (639.3 ± 278.8 με) and allowed the validation of computational models with a difference of 6.3% and 6.4% for the microstrains in the CMN and MC groups, respectively. Similarly, the results presented by the computational models showed no statistical difference (p = 0.932) for the CMN (605.1 ± 358.6 με) and MC (598.7 ± 357.9 με) groups. The study concluded that under favorable conditions the use of CMN or MP abutments to support a fixed partial denture can be indicated.
Collapse
Affiliation(s)
- Guilherme da Rocha Scalzer Lopes
- Department of Biomaterials, Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos 12245-000, Brazil or
| | - Jefferson David Melo de Matos
- Department of Biomaterials, Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos 12245-000, Brazil or
- Center for Dental Biomaterials, Department of Restorative Dental Sciences, University of Florida (UF Health), Gainesville, FL 32611, USA
| | - Daher Antonio Queiroz
- Department of Restorative Dentistry & Prosthodontics, The University of Texas Health Science Center at Houston (UTHealth) School of Dentistry, Houston, TX 77054, USA
| | - João Paulo Mendes Tribst
- Department of Oral Regenerative Medicine, Academic Centre for Dentistry Amsterdam (ACTA), The University of Amsterdam and Vrije Universiteit, 1081 LA Amsterdam, The Netherlands
| | - Nathália de Carvalho Ramos
- Department of Biomaterials, Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos 12245-000, Brazil or
- Department of Dentistry, Universidade São Francisco (USF), Bragança Paulista 12916-900, Brazil
| | - Mateus Garcia Rocha
- Center for Dental Biomaterials, Department of Restorative Dental Sciences, University of Florida (UF Health), Gainesville, FL 32611, USA
| | | | - Marco Antonio Bottino
- Department of Biomaterials, Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos 12245-000, Brazil or
| | - Alexandre Luiz Souto Borges
- Department of Biomaterials, Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos 12245-000, Brazil or
| | - Renato Sussumu Nishioka
- Department of Biomaterials, Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos 12245-000, Brazil or
| |
Collapse
|
8
|
Wu YL, Tsai MH, Chen HS, Lin CP, Wu AYJ. Effect of Marginal Bone Integrity and Aftermarket Abutment Screws on Dental Implant Systems-A Preliminary Study with Finite Element Method. MATERIALS (BASEL, SWITZERLAND) 2022; 15:5952. [PMID: 36079334 PMCID: PMC9457101 DOI: 10.3390/ma15175952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Revised: 08/22/2022] [Accepted: 08/25/2022] [Indexed: 06/15/2023]
Abstract
Bone resorption around implants is quite common, and the maturity and popularization of computer-aided design and computer-aided manufacturing (CAD/CAM) technology have made the use of aftermarket abutment screws more widespread. This study aimed to explore the biomechanical influence of these two common factors on the internal stress of an implant system using three-dimensional finite element analysis (3D FEA). The FEA results indicated that under the same loading conditions, the use of an aftermarket screw had the greatest impact on the screw itself among the three components of the implant system, while the maximum stress increased by 6.3% and 10.5% in the bone integrity and bone loss models, respectively. Moreover, the marginal bone loss models had the greatest impact on the implant fixture, with a maximum stress increase of 51.8% on average. Evidently, the influence of bone loss might be far greater than that of the aftermarket screw; however, any factor could be enough to cause clinical failure. Therefore, we should pay more attention to the maintenance of the long-term peri-implant marginal bone integrity.
Collapse
Affiliation(s)
- Yu-Ling Wu
- Department of Dentistry, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung 833, Taiwan
| | - Ming-Hsu Tsai
- Department of Mechanical Engineering, Cheng Shiu University, Kaohsiung 833, Taiwan
| | - Hung-Shyong Chen
- Department of Mechanical Engineering, Cheng Shiu University, Kaohsiung 833, Taiwan
- Center for Environmental Toxin and Emerging-Contaminant Research, Cheng Shiu University, Kaohsiung 833, Taiwan
| | - Ching-Ping Lin
- Department of Dentistry, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung 833, Taiwan
| | - Aaron Yu-Jen Wu
- Department of Dentistry, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung 833, Taiwan
| |
Collapse
|
9
|
Wang L, Fu ZH, Hu ZH, Li M, Qiu LH, Gao Z. Biomechanical behaviour of implant prostheses and adjacent teeth according to bone quality: A finite element analysis. Eur J Oral Sci 2022; 130:e12863. [PMID: 35342996 DOI: 10.1111/eos.12863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Accepted: 02/28/2022] [Indexed: 11/26/2022]
Abstract
The contribution of biomechanical factors in the formation of proximal contact loss has been observed, but there is little research on the mechanisms by which they contribute. Using finite element analysis, this study aimed to analyse the impact of bone quality on the biomechanical behaviour of a dentition consisting of implant prostheses and adjacent teeth. The occlusal load was applied on the implant/tooth crown. In the mesiodistal direction, the adjacent natural tooth mesially to the implant denture had the tendency for mesial movement, while the distal adjacent natural tooth had the tendency for distal movement. For the supporting bone around the mesial adjacent tooth, the maximum/minimum principal stress and strain values on the mesial side of the bone were higher than those on the distal side of the bone. Stress and strain values on the mesial side of the supporting bone around the distal adjacent tooth were lower than those on the distal side. With decreasing bone density, displacements of teeth and the implant denture, principal stresses and equivalent strains on tooth supporting bone increased. Studies on biomechanical behaviours of a tooth-implant dentition may provide a deeper understanding of implant-induced dental adaptive processes such as proximal contact loss.
Collapse
Affiliation(s)
- Lan Wang
- Department of Stomatology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Zhi-Hui Fu
- Department of Stomatology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Zhi-Hui Hu
- School of Electronic Science and Engineering, Xiamen University, Xiamen, China
| | - Min Li
- Department of Stomatology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Li-Hua Qiu
- Department of Oral and Maxillofacial Surgery, Stomatological Hospital of Chongqing Medical University, Chongqing, China
| | - Zhi Gao
- Department of Stomatology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| |
Collapse
|
10
|
Pelekhan B, Dutkiewicz M, Shatskyi I, Velychkovych A, Rozhko M, Pelekhan L. Analytical Modeling of the Interaction of a Four Implant-Supported Overdenture with Bone Tissue. MATERIALS 2022; 15:ma15072398. [PMID: 35407730 PMCID: PMC8999531 DOI: 10.3390/ma15072398] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Revised: 03/17/2022] [Accepted: 03/21/2022] [Indexed: 12/16/2022]
Abstract
Today, an interdisciplinary approach to solving the problems of implantology is key to the effective use of intraosseous dental implantations. The functional properties of restoration structures for the dentition depend significantly on the mechanical stresses that occur in the structural elements and bone tissues in response to mastication loads. An orthopedic design with a bar fixation system connected to implants may be considered to restore an edentulous mandible using an overdenture. In this study, the problem of the mechanics of a complete overdenture based on a bar and four implants was formulated. A mathematical model of the interaction between the orthopedic structure and jawbone was developed, and a methodology was established for the analytical study of the stress state of the implants and adjacent bone tissue under the action of a chewing load. The novelty of the proposed model is that it operates with the minimum possible set of input data and provides adequate estimates of the most significant output parameters that are necessary for practical application. The obtained analytical results are illustrated by two examples of calculating the equivalent stresses in implants and the peri-implant tissue for real overdenture designs. To carry out the final assessment of the strength of the implants and bone, the prosthesis was loaded with mastication loads of different localization. In particular, the possibilities of loading the prosthesis in the area of the sixth and seventh teeth were investigated. Recommendations on the configuration of the distal cantilever of the overdenture and the acceptable level and distribution of the mastication load are presented. It was determined that, from a mechanical point of view, the considered orthopedic systems are capable of providing long-term success if they are used in accordance with established restrictions and recommendations.
Collapse
Affiliation(s)
- Bohdan Pelekhan
- Department of Dentistry of Postgraduate Study Faculty, Ivano-Frankivsk National Medical University, Halytska Str. 2, 76018 Ivano-Frankivsk, Ukraine; (B.P.); (M.R.); (L.P.)
| | - Maciej Dutkiewicz
- Faculty of Civil and Environmental Engineering and Architecture, Bydgoszcz University of Science and Technology, Kaliskiego 7, 85-796 Bydgoszcz, Poland
- Correspondence:
| | - Ivan Shatskyi
- Laboratory of Modeling of Damping Systems, Pidstryhach-Institute for Applied Problems in Mechanics and Mathematics of the National Academy of Sciences of Ukraine, Mykytynetska Str. 3, 76002 Ivano-Frankivsk, Ukraine;
| | - Andrii Velychkovych
- Department of Construction and Civil Engineering, Ivano-Frankivsk National Technical University of Oil and Gas, Karpatska Str. 15, 76019 Ivano-Frankivsk, Ukraine;
| | - Mykola Rozhko
- Department of Dentistry of Postgraduate Study Faculty, Ivano-Frankivsk National Medical University, Halytska Str. 2, 76018 Ivano-Frankivsk, Ukraine; (B.P.); (M.R.); (L.P.)
| | - Liubomyr Pelekhan
- Department of Dentistry of Postgraduate Study Faculty, Ivano-Frankivsk National Medical University, Halytska Str. 2, 76018 Ivano-Frankivsk, Ukraine; (B.P.); (M.R.); (L.P.)
| |
Collapse
|
11
|
de Faria Almeida DA, Verri FR, Lemos CAA, de Souza Batista VE, Santiago Júnior JF, Rosa CDDRD, Noritomi PY, Pellizzer EP. Effect of Splinting of Tilted External Hexagon Implants on 3-Unit Implant-Supported Prostheses in the Posterior Maxilla: A 3D Finite Element Analysis. J Prosthodont 2021; 31:697-704. [PMID: 34859540 DOI: 10.1111/jopr.13460] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/25/2021] [Indexed: 11/28/2022] Open
Abstract
PURPOSE To assess the effects of tilted external hexagon implants and splinted restorations in terms of stress distribution on the bone tissue, implants, and prosthetic screws, using three-dimensional finite element analysis. MATERIALS AND METHODS Six models were used to simulate a posterior maxilla bone block (type IV) from the first premolar to the first molar. Each model included three 4.1-mm-diameter external hexagon implants with varying inclinations (0°, 17°, and 30°) and crown designs (splinted and nonsplinted restorations). The forces applied were as follows: 400 N axially (50 N for each slope of the cusp) and 200 N obliquely (45° only on the buccal slope of the cusp). Stress distribution on the implants and prosthetic screw was evaluated using Von Mises stress, while the maximum principal stress was used to evaluate the stress distribution in the bone tissue. RESULTS The oblique load increased the stress on all the structures in all the models. Increased inclination of the implants resulted in higher stress concentration in the bone tissue, implants, and prosthetic screws. However, splinted restorations contributed to reduction of the stress for the oblique loading, mainly in the bone tissue and prosthetic screw of the first molar, as the stress was shared between the first and second premolar restorations. CONCLUSIONS Tilted implants increased proportionally the stress on bone tissue and prosthetic screws of models. Additionally, splinting restorations reduced the stress concentration area in the simulated bone tissue, implants, and prosthetic screws in the first molar, as the stress was shared with the adjacent implants.
Collapse
Affiliation(s)
| | - Fellippo R Verri
- Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP - Univ Estadual Paulista, Araçatuba, Sao Paulo, Brazil
| | - Cleidiel A A Lemos
- Department of Dentistry, Federal University of Juiz de Fora (UFJF-GV), Governador Valadares, Minas Gerais, Brazil
| | - Victor E de Souza Batista
- Department Prosthodontics, Presidente Prudente Dental School, University of the West of São Paulo (UNOESTE), Presidente Prudente, Brazil
| | - Joel F Santiago Júnior
- Department of Health Sciences, Sagrado Coração University (USC), Bauru, Sao Paulo, Brazil
| | - Cleber D D R D Rosa
- Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP - Univ Estadual Paulista, Araçatuba, Sao Paulo, Brazil
| | - Pedro Y Noritomi
- Renato Archer's Information Technology Center, Campinas, Sao Paulo, Brazil
| | - Eduardo P Pellizzer
- Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP - Univ Estadual Paulista, Araçatuba, Sao Paulo, Brazil
| |
Collapse
|