1
|
Tribst JPM, Veerman A, Pereira GKR, Kleverlaan CJ, Dal Piva AMDO. Comparative Strength Study of Indirect Permanent Restorations: 3D-Printed, Milled, and Conventional Dental Composites. Clin Pract 2024; 14:1940-1952. [PMID: 39311304 PMCID: PMC11417927 DOI: 10.3390/clinpract14050154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2024] [Revised: 09/14/2024] [Accepted: 09/19/2024] [Indexed: 09/26/2024] Open
Abstract
Background/Objectives: Limited research has been performed to assess the strength of resin-bonded 3D-printed restorations. Based on that, this study investigates the impact of different manufacturing methods on the fracture load of indirect composite restorations (ICRs) following an aging process. Methods: Three manufacturing techniques-conventional (CRC), milled (MRC), and printed (PRC)-were evaluated using 60 specimens, each with a diameter of 10 mm and a thickness of 1.0 mm. Sandblasting with Al2O3 particles was employed to optimize the bonding process, significantly influencing surface roughness parameters (Ra, Rz, RSm). All specimens were bonded to the dentin analog using composite resin cement and subjected to either 10,000 thermocycles (TC) or storage (ST) at 37 °C in distilled water. Fracture load assessments were performed using a universal testing machine. A finite element analysis was conducted to assess stress distribution. Results: Two-way ANOVA results indicated that the manufacturing method significantly affected mean fracture load values (p < 0.001), with PRC showing the highest mean fracture load (4185 ± 914 N), followed by MRC (2495 ± 941 N) and CRC (599 ± 292 N). The aging protocol did not have a significant impact on fracture load. Conclusions: This study revealed that 3D-printed resin composite exhibited comparable strength to milled resin composite when adhesively cemented, suggesting it is a promising option for indirect composite restorations based on its mechanical performance. However, further research is needed to evaluate its bond strength and optimal surface treatment methods to prevent early debonding.
Collapse
Affiliation(s)
- João Paulo Mendes Tribst
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, 1081LA Amsterdam, North Holland, The Netherlands
| | - Adelheid Veerman
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, 1081LA Amsterdam, North Holland, The Netherlands
| | - Gabriel Kalil Rocha Pereira
- Department of Restorative Dentistry, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria 97105900, Rio Grande do Sul State, Brazil;
| | - Cornelis Johannes Kleverlaan
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, 1081LA Amsterdam, North Holland, The Netherlands; (C.J.K.); (A.M.d.O.D.P.)
| | - Amanda Maria de Oliveira Dal Piva
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, 1081LA Amsterdam, North Holland, The Netherlands; (C.J.K.); (A.M.d.O.D.P.)
| |
Collapse
|
2
|
Lenz U, Santos RB, Griggs JA, Estrela C, Bueno MDR, Porto OCL, Della Bona A. Longevity of different abutments placed on narrow diameter implants: Assessment of structural damage and loosening. Dent Mater 2024; 40:1332-1340. [PMID: 38876825 DOI: 10.1016/j.dental.2024.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 05/29/2024] [Accepted: 06/03/2024] [Indexed: 06/16/2024]
Abstract
OBJECTIVES To evaluate structural damage and loosening of abutments placed on narrow diameter implants after cyclic fatigue. METHODS Sixty Morse taper narrow diameter implants (Neodent, Brazil) received two types of abutments (1PA- one-piece abutment or 2PA- two-piece abutment), which were randomly divided into 3 fatigue experiments (n = 10). The implants were placed into a customized supporting holder and a software-assisted digital torque wrench secured the manufacturer recommended torque for each abutment. Cone beam computed tomography (CBCT) scans were acquired, before and after fatigue, and post-processed (software e-Vol DX) to assess damage and abutment displacement. The boundary fatigue method was adapted to use 2 × 106 cycles, 2 Hz of frequency and constant peak load of 80 N (first experiment) that varied according to the failure rate of previous specimens (second and third experiments). Failure was evaluated using CBCT scans and removal torque values. Data were used to estimate long-term torque degradation, probability of failure and Weibull modulus (software ALTA PRO9). RESULTS All 2PA specimens became loosen independently of the applied fatigue load, and structural bending was observed in 14 abutments. Eight 1PA got loosen during the fatigue experiment. The Weibull analysis showed a lower modulus (m = 1.0; 0.7, 1.4) for 1PA than for 2PA (m = 2.6; 2, 3.4) resulting in longer predicted lifetimes and slower torque degradation for 1PA than for 2PA specimens. SIGNIFICANCE 1PA showed greater long-term survival probability than 2PA. Predicting the lifetime and mechanical behavior of implant-abutment systems are useful information to clinicians during the decision-making process of oral rehabilitations.
Collapse
Affiliation(s)
- Ulysses Lenz
- Postgraduate Program in Dentistry, School of Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
| | - Renan Brandenburg Santos
- Postgraduate Program in Dentistry, School of Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
| | - Jason Alan Griggs
- Department of Biomedical Materials Science, University of Mississippi Medical Center, MS, USA
| | - Carlos Estrela
- School of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil
| | | | | | - Alvaro Della Bona
- Postgraduate Program in Dentistry, School of Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil.
| |
Collapse
|
3
|
Rizzatto LV, Meneghetti D, Di Domênico M, Facenda JC, Weber KR, Corazza PH, Borba M. Effect of the type of resin cement on the fracture resistance of chairside CAD-CAM materials after aging. J Adv Prosthodont 2023; 15:136-144. [PMID: 37441719 PMCID: PMC10333098 DOI: 10.4047/jap.2023.15.3.136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 06/05/2023] [Accepted: 06/20/2023] [Indexed: 07/15/2023] Open
Abstract
PURPOSE The study objective was to evaluate the influence of the type of resin cement on the flexural strength and load to fracture of two chairside CAD-CAM materials after aging. MATERIALS AND METHODS A polymer-infiltrated ceramic network (PICN) and a nanoceramic resin (RNC) were used to produce the specimens. Two types of dual-cure resin cements, a self-adhesive and a universal, were investigated. Bilayer specimens were produced (n = 10) and aged for 6 months in a humid environment before the biaxial flexural strength test (σf). Bonded specimens were subjected to a mechanical aging protocol (50 N, 2 Hz, 37℃ water, 500,000 cycles) before the compressive load test (Lf). σf and Lf data were analyzed using two-way ANOVA and Tukey tests (α = .05). Chi-square test was used to analyze the relationship between failure mode and experimental group (α = .05). RESULTS The type of resin cement and the interaction between factors had no effect on the σf and Lf of the specimens, while the type of restorative material was significant. RNC had higher σf and Lf than PICN. There was a significant association among the type of cracks identified for specimens tested in Lf and the restorative material. CONCLUSION The type of resin cement had no effect on the flexural strength and load to fracture of the two investigated CAD-CAM chairside materials after aging.
Collapse
Affiliation(s)
| | - Daniel Meneghetti
- School of Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
| | - Marielle Di Domênico
- Graduate Program in Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
| | - Júlia Cadorin Facenda
- Graduate Program in Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
- Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil
| | - Katia Raquel Weber
- Graduate Program in Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
- Department of Dentistry, School of Health Sciences, Positivo University, Curitiba, PR, Brazil
| | | | - Márcia Borba
- Graduate Program in Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
| |
Collapse
|
4
|
Effects of material and piston diameter on the fatigue behavior, failure mode, and stress distribution of feldspathic ceramic simplified restorations. J Mech Behav Biomed Mater 2022; 134:105398. [DOI: 10.1016/j.jmbbm.2022.105398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Revised: 07/16/2022] [Accepted: 07/20/2022] [Indexed: 11/21/2022]
|
5
|
Grassi EDA, de Andrade GS, Tribst JPM, Machry RV, Valandro LF, Ramos NDC, Bresciani E, Saavedra GDSFA. Fatigue behavior and stress distribution of molars restored with MOD inlays with and without deep margin elevation. Clin Oral Investig 2021; 26:2513-2526. [PMID: 34643807 DOI: 10.1007/s00784-021-04219-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Accepted: 10/04/2021] [Indexed: 11/26/2022]
Abstract
OBJECTIVES This study evaluated the effect of deep margin elevation (DME) and restorative materials (leucite-reinforced glass-ceramics [C] vs. indirect resin composite [R]) on the fatigue behavior and stress distribution of maxillary molars with 2-mm deep proximal margins restored with MOD inlay. METHODS Fifty-two extracted human third molars were randomly assigned into four groups (n = 13): C; DME + C; R; and DME + R. Inlays were fabricated in CAD-CAM and bonded to all teeth. The fatigue behavior was assessed with the stepwise stress test (10,000 cycles/step; step = 50 N; 20 Hz; initial load = 200 N). Fatigue failure loads and the number of cycles were analyzed with 2-way ANOVA and Tukey's test (p < 0.05) and Kaplan-Meier survival plots. The stress distribution was assessed with finite element analysis. The models were considered isotropic, linear, and homogeneous, and presented bonded contacts. A tripod axial load (400 N) was applied to the occlusal surface. The stress distribution was analyzed with the maximum principal stress criterion. RESULTS For fatigue, there was no difference for DME factor (p > 0.05). For the material factor, the load and number of cycles for failure were statistically higher in the R groups (p < 0.05). The finite element analysis showed that resin composite inlays concentrated more stress in the tooth structure, while ceramic inlays concentrated more stress in the restoration. Non-reparable failures were more frequent in the resin composite inlays groups. CONCLUSIONS DME was not negative for fatigue and biomechanical behaviors. Resin composite inlays were more resistant to the fatigue test, although the failure mode was more aggressive. CLINICAL SIGNIFICANCE DME does not impair mechanical behavior. Resin composite inlays failed at higher loads but with a more aggressive failure mode.
Collapse
Affiliation(s)
- Elisa Donaria Aboucauch Grassi
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), 777th Eng. Francisco José Longo Av., São José dos Campos, SP, 12245-000, Brazil
| | - Guilherme Schmitt de Andrade
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), 777th Eng. Francisco José Longo Av., São José dos Campos, SP, 12245-000, Brazil
| | - João Paulo Mendes Tribst
- Post-Graduate Program in Dentistry, University of Taubaté (UNITAU), 09th Rua Dos Operários St., Taubaté, SP, 12020-340, Brazil
| | - Renan Vaz Machry
- Graduate Program of Oral Science, Prosthodontics Unit, School of Dentistry, Federal University of Santa Maria (UFSM), Roraima Av, Santa Maria, RS, 100097105-340, Brazil
| | - Luiz Felipe Valandro
- Graduate Program of Oral Science, Prosthodontics Unit, School of Dentistry, Federal University of Santa Maria (UFSM), Roraima Av, Santa Maria, RS, 100097105-340, Brazil
| | - Nathalia de Carvalho Ramos
- School of Dentistry, São Francisco University (USF), 218th São Francisco de Assis Av., Bragança Paulista, SP, 12916-900, Brazil
| | - Eduardo Bresciani
- Department of Restorative Dentistry, Institute of Science and Technology, São Paulo State University (Unesp), 777th Eng. Francisco José Longo Av., São José dos Campos, SP, 12245-000, Brazil
| | - Guilherme de Siqueira Ferreira Anzaloni Saavedra
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), 777th Eng. Francisco José Longo Av., São José dos Campos, SP, 12245-000, Brazil.
| |
Collapse
|