1
|
Silva JR, Curado TFF, Srinivasan M, Schimmel M, McKenna G, Leles CR. Mandibular overdenture retained by four one-piece titanium-zirconium mini implants: A 2-year follow-up on prosthodontic outcomes. J Dent 2024; 149:105266. [PMID: 39067651 DOI: 10.1016/j.jdent.2024.105266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2024] [Revised: 07/09/2024] [Accepted: 07/23/2024] [Indexed: 07/30/2024] Open
Abstract
OBJECTIVE This 2-year prospective study reports the incidence of prosthetic complications and maintenance events after treatment with mandibular overdenture retained by four mini implants opposed to a maxillary denture. METHODS Implant intervention included flapless or flapped surgery combined with immediate or delayed loading, as part of a randomized clinical trial. Four one-piece titanium-zirconium mini-implants (Straumann Mini Implant System) were inserted, and the retentive PEEK elements (Optiloc) were incorporated into the overdenture using chairside procedures. Prosthodontic complications and maintenance events were recorded over a 2-year follow-up, and the final outcome was defined according to standardized criteria. Data analysis included descriptive statistics, incidence and incidence density rates, and Kaplan-Meier survival. RESULTS 73 out of 74 patients (64.9 % female), mean age of 64 (SD=8.2) years, completed the study follow-up (one withdrew after 9 months). Implant survival was 100 %. A total of 163 prosthodontic events occurred in 53 patients (72.6 %), and 20 patients had no clinical complaints or maintenance needs. The most common procedures were adjustment/repair of the overdenture base (47.0 %), replacement of retentive inserts (19.8 %), and laboratory relining (12.9 %). A high prosthodontic success rate was achieved (93.2 %), and all patients presented serviceable overdentures and continuous use after the resolution of prosthodontic complications. The incidences of matrix replacement and laboratory relines were low in the first year, while denture base adjustments were common within the first year, especially in the first 6 months. CONCLUSION The mini implant system showed high prosthodontic success rates. Minor adjustments/repairs during the initial follow-up were common. Relines and matrix replacements tend to occur after one year of overdenture use, and matrix replacements may occur as a consequence of the need for relining.
Collapse
Affiliation(s)
| | | | - Murali Srinivasan
- Clinic of General-, Special Care- and Geriatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Martin Schimmel
- Department of Reconstructive Dentistry, Division of Gerodontology, School of Dental Medicine of the University of Bern, Bern, Switzerland; Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Gerald McKenna
- Oral Health Services and Gerodontology, Centre for Public Health, Queen's University Belfast, Belfast, UK
| | - Cláudio Rodrigues Leles
- School of Dentistry, Federal University of Goias, Goiania, Brazil; Clinic of General-, Special Care- and Geriatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland; Department of Reconstructive Dentistry, Division of Gerodontology, School of Dental Medicine of the University of Bern, Bern, Switzerland.
| |
Collapse
|
2
|
Petricevic N, Celebic A, Puljic D, Milat O, Divjak A, Kovacic I. Effects of Loading Forces, Loading Positions, and Splinting of Two, Three, or Four Ti-Zr (Roxolid ®) Mini-Implants Supporting the Mandibular Overdentures on Peri-Implant and Posterior Edentulous Area Strains. J Funct Biomater 2024; 15:260. [PMID: 39330235 PMCID: PMC11433416 DOI: 10.3390/jfb15090260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2024] [Revised: 08/30/2024] [Accepted: 09/03/2024] [Indexed: 09/28/2024] Open
Abstract
Clinical indications for the Ti-Zr alloy (Roxolid®) mini-implants (MDIs) in subjects with narrow ridges are still under review. The aim was to analyze peri-implant and posterior edentulous area strains dependent on the MDI number, splinting status, loading force, and loading position. Six models were digitally designed and printed. Two, three, or four Ti-Zr MDIs, splinted with a bar or unsplinted (single units), supported mandibular overdentures (ODs), loaded with 50-300 N forces unilaterally, bilaterally, and anteriorly. The artificial mucosa thickness was 2 mm. Strain gauges were bonded on the vestibular and oral peri-implant sides of each MDI, and on the posterior edentulous area under the ODs. Loadings were performed through the metal plate placed on ODs' artificial teeth (15 times repeated). Arithmetic means with standard deviations and the significance of the differences (MANOVA, Sheffe post hoc) were calculated. Different MDI numbers, loading positions, forces, and splinting elicited different peri-implant microstrains. In the two-MDI models, 300 N force during unilateral loading elicited the highest microstrains (almost 3000 εμ on the loaded side), which can jeopardize bone reparation. On the opposite side, >2500 εμ was registered, which represents high strains. During bilateral loadings, microstrains hardly exceeded 2000 εμ, indicating that bilateral chewers or subjects having lower forces can benefit from the two Ti-Zr MDIs, irrespective of splinting. However, in subjects chewing unilaterally, and inducing higher forces (natural teeth antagonists), or bruxers, only two MDIs may not be sufficient to support the OD. By increasing implant numbers, peri-implant strains decrease in both splinted and single-unit MDI models, far beyond values that can interfere with bone reparation, indicating that splinting is not necessary. When the positions of the loading forces are closer to the implant, higher peri-implant strains are induced. Regarding the distal edentulous area, microstrains reached 2000 εμ only during unilateral loadings in the two-MDI models, and all other strains were lower, below 1500 εμ, confirming that implant-supported overdentures do not lead to edentulous ridge atrophy.
Collapse
Affiliation(s)
- Nikola Petricevic
- Department of Removable Prosthodontics, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Asja Celebic
- Department of Removable Prosthodontics, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Dario Puljic
- Department of Removable Prosthodontics, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | | | - Alan Divjak
- Department of Digital Arts, University Algebra, 10000 Zagreb, Croatia
| | - Ines Kovacic
- Department of Removable Prosthodontics, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| |
Collapse
|
3
|
de Oliveira Rigotti RL, Tardelli JDC, Dos Reis AC, da Valente MLC. Influence of dental implant/mini-implant design on stress distribution in overdentures: a systematic review. Oral Maxillofac Surg 2024; 28:515-527. [PMID: 37665393 DOI: 10.1007/s10006-023-01177-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Accepted: 08/18/2023] [Indexed: 09/05/2023]
Abstract
PURPOSE Critically evaluate the existing literature and answer the question, "Does the dental implant/mini-implant design influence the stress distribution in prosthetic overdentures according to finite element analysis?". METHODS This systematic review was registered in the Open Science Framework (osf.io/2bquj) and followed the PRISMA protocols. The custom search strategy was applied to 4 databases. In vitro experimental studies that evaluated the influence of dental implant/mini-implant design on stress distribution in overdentures by FEM, without time and language restrictions, were included. The selection process was carried out in two stages by two reviewers independently. Risk of bias analysis was performed by a checklist of important parameters. RESULTS Sixty articles were evaluated by their title and abstract, four were selected for full reading, three were relevant, and nine were included by additional search. The 12 studies have a low risk of bias. The meta-analysis could not be performed due to the heterogeneity of the data (implant type, design variation, load intensity, and direction). CONCLUSION It can be inferred from the evaluated literature that design modifications influence the stress distribution, but as the FEM presents limitations inherent to the in vitro study, clinical trials are necessary to infer the effectiveness of the modifications. It should be noted that there is no consensus on which is the best thread design and that implants with a very narrow diameter are subject to the highest stress concentration.
Collapse
Affiliation(s)
- Renan Leonardi de Oliveira Rigotti
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, USP-University of São Paulo, Av. Do Café, S/N, Ribeirão Preto, SP, 14040-904, Brazil
| | - Juliana Dias Corpa Tardelli
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, USP-University of São Paulo, Av. Do Café, S/N, Ribeirão Preto, SP, 14040-904, Brazil
| | - Andréa Cândido Dos Reis
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, USP-University of São Paulo, Av. Do Café, S/N, Ribeirão Preto, SP, 14040-904, Brazil
| | - Mariana Lima Costa da Valente
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, USP-University of São Paulo, Av. Do Café, S/N, Ribeirão Preto, SP, 14040-904, Brazil.
| |
Collapse
|
4
|
Celebic A, Kovacic I, Petricevic N, Alhajj MN, Topic J, Junakovic L, Persic-Kirsic S. Clinical Outcomes of Three versus Four Mini-Implants Retaining Mandibular Overdenture: A 5-Year Randomized Clinical Trial. MEDICINA (KAUNAS, LITHUANIA) 2023; 60:17. [PMID: 38276051 PMCID: PMC10820318 DOI: 10.3390/medicina60010017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 12/11/2023] [Accepted: 12/18/2023] [Indexed: 01/27/2024]
Abstract
Background and Objectives: Due to a lack of long-term clinical studies that would clarify whether the insertion of three mini-implants (MDIs) can be as successful treatment as the insertion of four MDIs for the retention of mandibular overdentures (ODs), this 5-year prospective cohort study was set up. Materials and Methods: Participants (n = 83) randomly received either four or three MDIs and a mandibular OD. Clinical examinations were performed at the baseline, as well as after one, three, and five years, respectively. A total of 73 participants (38 in the four-MDI and 35 in the three-MDI groups) partook in the study. The marginal bone level change, success and survival rates, and prosthodontic maintenance were assessed. Results: Repeated measures showed that the mean peri-implant bone loss increased progressively at a small amount over five years in both groups (four-MDI group = -0.36 ± 0.74; three-MDI group = -0.33 ± 0.27 mm; p < 0.05). However, an ANCOVA revealed no significant effects of the group (no significant difference between the three- and the four-MDI groups; F = 0.085; p = 0.771), gender (F = 0.023; p = 0.88), or covariate age (F = 1.95; p = 0.167) on the dependent variable: the 5-year MBL change. The success rate (together with successful survival) was 93.8% in the four-MDI group and 91.7% in the three-MDI group. The log-rank (Mantel-Cox) test revealed no significant differences between them (X2 = 0.373; p = 0.541). Conclusions: In patients with narrow ridges, the insertion of three MDIs in the mandible for overdenture retention can be equally as successful as the insertion of four MDIs.
Collapse
Affiliation(s)
- Asja Celebic
- Department of Removable Prosthodontics, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia; (N.P.); (S.P.-K.)
| | - Ines Kovacic
- Department of Removable Prosthodontics, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia; (N.P.); (S.P.-K.)
| | - Nikola Petricevic
- Department of Removable Prosthodontics, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia; (N.P.); (S.P.-K.)
| | - Mohammed Nasser Alhajj
- Department of Prosthodontics, Faculty of Dentistry, Thamar University, Thamar 87246, Yemen;
| | - Jolanda Topic
- Private Dental Office, 21300 Makarska, Croatia;
- School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Luka Junakovic
- Mag. Math., Libertas International University, 10000 Zagreb, Croatia;
| | - Sanja Persic-Kirsic
- Department of Removable Prosthodontics, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia; (N.P.); (S.P.-K.)
| |
Collapse
|
5
|
Curado TFF, Silva JR, Nascimento LN, Leles JLR, McKenna G, Schimmel M, Leles CR. Implant survival/success and peri-implant outcomes of titanium-zirconium mini implants for mandibular overdentures: Results from a 1-year randomized clinical trial. Clin Oral Implants Res 2023; 34:769-782. [PMID: 37254798 DOI: 10.1111/clr.14102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 04/15/2023] [Accepted: 05/18/2023] [Indexed: 06/01/2023]
Abstract
OBJECTIVE To report the 1-year implant survival/success and peri-implant outcomes of mandibular overdentures retained by four titanium-zirconium mini implants (Straumann® Mini Implant System), and to assess how surgery and loading protocols influence these outcomes. MATERIALS AND METHODS A 2 × 2 factorial randomized clinical trial (RCT) tested the combined effects of two loading protocols (immediate or delayed) and two surgical approaches (flapless or flapped) on the success/survival of the mini implants, and peri-implant parameters (plaque, bleeding, sulcus depth, gingival position, and marginal bone loss). Outcomes were assessed up to 1-year after loading, and generalized estimating equations (GEEs) were used to analyze longitudinal and within-patient clustered data. RESULTS Two hundred and ninety-six implants were placed in 74 patients. The implant survival/success rates after 1 year were 100%, and no major biological complications were observed. After 1-year, descriptive data suggest no noticeable changes in plaque scores, whilst a reduction in bleeding scores at the 6-month and 1-year follow-ups compared to baseline. Good longitudinal stability was observed for the probing depth and gingival margin height measures. Overall mean marginal bone loss was 0.68 (±0.68) mm after 3 months and 0.89 (±0.75) mm after 1-year. The flapless protocol showed better results on soft tissue stability and health but a slightly higher risk for marginal bone loss. CONCLUSION The results of this RCT suggest that mandibular overdentures retained by this novel mini implant system represent a safe and predictable treatment option as confirmed by implant survival/success and peri-implant outcomes, even when flapless surgery and immediate loading protocols are adopted.
Collapse
Affiliation(s)
| | | | | | | | - Gerald McKenna
- Centre for Public Health, Queen's University Belfast, Belfast, UK
| | - Martin Schimmel
- Department of Reconstructive Dentistry, Division of Gerodontology, School of Dental Medicine of the University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Cláudio Rodrigues Leles
- School of Dentistry, Federal University of Goias, Goiania, Brazil
- Department of Reconstructive Dentistry, Division of Gerodontology, School of Dental Medicine of the University of Bern, Bern, Switzerland
| |
Collapse
|
6
|
Mini-Implants Retaining Removable Partial Dentures in Subjects without Posterior Teeth: A 5-Year Prospective Study Comparing the Maxilla and the Mandible. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:medicina59020237. [PMID: 36837439 PMCID: PMC9959138 DOI: 10.3390/medicina59020237] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 01/20/2023] [Accepted: 01/22/2023] [Indexed: 01/31/2023]
Abstract
Background and objectives: Long-term studies of clinical outcomes of mini-implants (MDIs) in the first premolar/canine sites retaining a bilateral free-ending removable partial dentures (RPD) in Kennedy class I subjects have not been well documented. The aim was to assess clinical outcomes in a prospective 5-year cohort study comparing the mandible and maxilla. Material and Methods: Participants (n = 92) who received two MDIs each and a new RPD were reviewed after one, three and five years. A total of 71 participants (82 mini-implants in the mandible; 58 in the maxilla) completed the study. Marginal bone level change, success, survival rates, Modified Plaque (MPI) and Bleeding Indices (MBI) were assessed. Results: The five-year success rate was 93.3% and 93.4% (p > 0.05), in the mandible and the maxilla, respectively. Mean peri-implant bone loss (MBL) increased significantly over five years (p < 0.01) to 0.50 mm in the mandible and 0.52 mm in the maxilla. Age had a significant effect on the MBL (higher rates in younger participants), while jaw of insertion, gender, and antagonistic jaw status did not. MPI and MBI were not significantly correlated with MBL. Conclusions: The insertion of two MDIs in previous first premolar/canine sites for retention of a free-end saddle RPD can be a successful treatment modality in subjects with narrow alveolar ridges.
Collapse
|
7
|
Teodorescu C, Preoteasa E, Preoteasa CT, Murariu-Măgureanu C, Teodorescu IM. The Biomechanical Impact of Loss of an Implant in the Treatment with Mandibular Overdentures on Four Nonsplinted Mini Dental Implants: A Finite Element Analysis. MATERIALS (BASEL, SWITZERLAND) 2022; 15:8662. [PMID: 36500160 PMCID: PMC9739263 DOI: 10.3390/ma15238662] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 12/01/2022] [Accepted: 12/02/2022] [Indexed: 06/17/2023]
Abstract
The aim of this study was to evaluate the biomechanical impact, in terms of stress and displacement, at the level of a mandibular overdenture, on four mini dental implants (MDIs) after the loss of an implant. A three-dimensional virtual model was obtained by scanning the overdenture, and a biomechanical analysis was carried out, using the finite element method (FEM). The displacements of the overdenture and the equivalent von Mises stresses were evaluated using logarithmic scales. In the case of a mandibular overdenture on four MDIs inserted in the interforaminal area, the frontal loading generated the lowest values for the von Mises stresses, and the bilateral loading generated the least displacement when two implants were inserted in the canine area and two in the molar area. The highest von Mises stress was observed during frontal loading in the situation of the mandibular overdenture on four MDIs, two of which were inserted in the canine area and two in the molar area, following the loss of an implant in the canine area. The largest displacement was noted in the mandibular overdenture on four interforaminal MDIs during unilateral loading, following the loss of a distally inserted implant. The FEM analysis showed aspects that correlated with clinical observations, with predictive value. The concentration of von Mises stresses, and the occurrence of some displacements of the prosthodontic restoration, can explain the emergence of some complications in the overdenture's biodynamics, and the increased risk of fracture. Complications can be prevented by choosing a certain number of implants and a topographical distribution correlated with biomechanical aspects, and by proposing a correct occlusal scheme with optimal functional loading.
Collapse
Affiliation(s)
- Cristian Teodorescu
- Department of Prosthodontics, Faculty of Dentistry, “Carol Davila” University of Medicine and Pharmacy, 020021 Bucharest, Romania
| | - Elena Preoteasa
- Department of Prosthodontics, Faculty of Dentistry, “Carol Davila” University of Medicine and Pharmacy, 020021 Bucharest, Romania
| | - Cristina Teodora Preoteasa
- Department of Scientific Research Methods-Ergonomics, Faculty of Dentistry, “Carol Davila” University of Medicine and Pharmacy, 020021 Bucharest, Romania
| | - Cătălina Murariu-Măgureanu
- Department of Prosthodontics, Faculty of Dentistry, “Carol Davila” University of Medicine and Pharmacy, 020021 Bucharest, Romania
| | - Ioana Monica Teodorescu
- Department of Prosthodontics, Faculty of Dentistry, “Carol Davila” University of Medicine and Pharmacy, 020021 Bucharest, Romania
| |
Collapse
|