Iwana-Yamada M, Shibamoto Y, Baba F, Iwata H, Ishikura S, Nagayoshi J, Hiwatashi A, Ogino H. Dose Prescription to Isodose Lines in Static Multi-Beam Stereotactic Body Radiotherapy for Lung Tumors: Which Line Is Optimal? Kurume Med J 2024; 69:217-226. [PMID: 38233174 DOI: 10.2739/kurumemedj.ms6934016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2024]
Abstract
This study investigated the appropriate dose prescription method in static multi-beam stereotactic body radiotherapy for lung tumors. Static multi-beam stereotactic body radiotherapy is a mainstream treatment in Japan. Based on the hypothesis that dose prescription to lower isodose lines may improve planning target volume dose coverage and decrease doses to organs at risk, we investigated changes in dose-volume histograms with prescription to various isodose lines for planning target volume in static multi-beam stereotactic body radiotherapy. In all treatment plans, 45 Gy in 4 fractions were prescribed to 95% of the planning target volume. By adjusting the leaf margins of each beam, various prescription isodose lines encompassing 95% volume of the planning target volume were generated. The prescription isodose lines investigated were 40, 50, 60, 70, 80 and 90% lines relative to the maximum dose of each planning target volume. The conformity index, homogeneity index, mean lung dose, and V5-V40 of the lung were evaluated. The dose was calculated by the adaptive convolve algorithm. The conformity index was lowest in the 70% or 80% isodose plan. The mean lung doses and V10-V40 of the lung decreased steeply from the 90% to the 70% isodose plan, and was lowest in the 60% and 70% isodose plans. These indices increased in the 40% and 50% isodose plans. The optimal stereotactic body radiotherapy plans appeared to be dose prescription to the 60% or 70% isodose line. Further investigation is warranted to clarify the advantage of using this method clinically.
Collapse
Affiliation(s)
- Maho Iwana-Yamada
- Department of Radiotherapy, Nagoya Proton Therapy Center
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences
| | - Yuta Shibamoto
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences
| | - Fumiya Baba
- Department of Radiotherapy, Nagoya Proton Therapy Center
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences
| | - Hiromitsu Iwata
- Department of Radiation Oncology, Nagoya Proton Therapy Center
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences
| | - Satoshi Ishikura
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences
| | - Junpei Nagayoshi
- Department of Radiological Technology, Nagoya City University West Medical Center
| | - Akio Hiwatashi
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences
| | - Hiroyuki Ogino
- Department of Radiation Oncology, Nagoya Proton Therapy Center
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences
| |
Collapse
|
2
|
Zhang W, Oraiqat I, Litzenberg D, Chang KW, Hadley S, Sunbul NB, Matuszak MM, Tichacek CJ, Moros EG, Carson PL, Cuneo KC, Wang X, El Naqa I. Real-time, volumetric imaging of radiation dose delivery deep into the liver during cancer treatment. Nat Biotechnol 2023; 41:1160-1167. [PMID: 36593414 PMCID: PMC10314963 DOI: 10.1038/s41587-022-01593-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Accepted: 11/01/2022] [Indexed: 01/04/2023]
Abstract
Ionizing radiation acoustic imaging (iRAI) allows online monitoring of radiation's interactions with tissues during radiation therapy, providing real-time, adaptive feedback for cancer treatments. We describe an iRAI volumetric imaging system that enables mapping of the three-dimensional (3D) radiation dose distribution in a complex clinical radiotherapy treatment. The method relies on a two-dimensional matrix array transducer and a matching multi-channel preamplifier board. The feasibility of imaging temporal 3D dose accumulation was first validated in a tissue-mimicking phantom. Next, semiquantitative iRAI relative dose measurements were verified in vivo in a rabbit model. Finally, real-time visualization of the 3D radiation dose delivered to a patient with liver metastases was accomplished with a clinical linear accelerator. These studies demonstrate the potential of iRAI to monitor and quantify the 3D radiation dose deposition during treatment, potentially improving radiotherapy treatment efficacy using real-time adaptive treatment.
Collapse
Affiliation(s)
- Wei Zhang
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Ibrahim Oraiqat
- Department of Machine Learning, Moffitt Cancer Center, Tampa, FL, USA
| | - Dale Litzenberg
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, USA
| | - Kai-Wei Chang
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Scott Hadley
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, USA
| | - Noora Ba Sunbul
- Department of Nuclear Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Martha M Matuszak
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, USA
- Department of Nuclear Engineering, University of Michigan, Ann Arbor, MI, USA
| | | | - Eduardo G Moros
- Department of Radiation Oncology, Moffitt Cancer Center, Tampa, FL, USA
| | - Paul L Carson
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
- Department of Radiology, University of Michigan, Ann Arbor, MI, USA
| | - Kyle C Cuneo
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, USA.
| | - Xueding Wang
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
- Department of Radiology, University of Michigan, Ann Arbor, MI, USA.
| | - Issam El Naqa
- Department of Machine Learning, Moffitt Cancer Center, Tampa, FL, USA.
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, USA.
- Department of Radiation Oncology, Moffitt Cancer Center, Tampa, FL, USA.
| |
Collapse
|
3
|
Fujiwara M, Kitada F. Clinical Experience of Intra-tumoral Central-Dose Escalated Volumetric Modulated Arc Therapy for Lymph Node Metastases in Patients With Advanced Cancer. Cureus 2023; 15:e34995. [PMID: 36938256 PMCID: PMC10020031 DOI: 10.7759/cureus.34995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/07/2023] [Indexed: 02/16/2023] Open
Abstract
Background Lymph node metastases (LN mets) are radioresistant, and high-dose irradiation is preferred for their control. The volumetric-modulated arc therapy technique makes it possible to perform intra-tumoral dose escalation without increasing the total prescribed dose of fractionated irradiation. We report its clinical experiences with intra-tumoral central-dose escalated volumetric-modulated arc therapy (ICE-VMAT) for LN mets. Materials and methods This study retrospectively evaluated 31 patients with 50 LN mets from stage III and IV advanced cancers who received ICE-VMAT. The total described dose was 50 Gy, and the median intra-tumoral central dose was 66 Gy (range, 54-79 Gy). Results The median follow-up period was 21 months. The two-year local control and overall survival (OS) rates were 95% and 56%, whereas univariate analysis revealed that the KPS ≥ 80 group had a significantly better OS compared to the KPS < 80 group. Conclusion ICE-VMAT was effective for LN mets. Patients with good KPS may benefit from therapeutic intervention with ICE-VMAT, even if they have multiple distant LN mets.
Collapse
|
4
|
Verification of an optimizer algorithm by the beam delivery evaluation of intensity-modulated arc therapy plans. Radiol Oncol 2021; 55:508-515. [PMID: 34821138 PMCID: PMC8647790 DOI: 10.2478/raon-2021-0046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Accepted: 08/17/2021] [Indexed: 11/20/2022] Open
Abstract
Background In the case of dynamic radiotherapy plans, the fractionation schemes can have dosimetric effects. Our goal was to define the effect of the fraction dose on the plan quality and the beam delivery. Materials and methods Treatment plans were created for 5 early-stage lung cancer patients with different dose schedules. The planned total dose was 60 Gy, fraction dose was 2 Gy, 3 Gy, 5 Gy, 12 Gy and 20 Gy. Additionally renormalized plans were created by changing the prescribed fraction dose after optimization. The dosimetric parameters and the beam delivery parameters were collected to define the plan quality and the complexity of the treatment plans. The accuracy of dose delivery was verified with dose measurements using electronic portal imaging device (EPID). Results The plan quality was independent from the used fractionation scheme. The fraction dose could be changed safely after the optimization, the delivery accuracy of the treatment plans with changed prescribed dose was not lower. According to EPID based measurements, the high fraction dose and dose rate caused the saturation of the detector, which lowered the gamma passing rate. The aperture complexity score, the gantry speed and the dose rate changes were not predicting factors for the gamma passing rate values. Conclusions The plan quality and the delivery accuracy are independent from the fraction dose, moreover the fraction dose can be changed safely after the dose optimization. The saturation effect of the EPID has to be considered when the action limits of the quality assurance system are defined.
Collapse
|
5
|
Tateishi Y, Takeda A, Horita N, Tsurugai Y, Eriguchi T, Kibe Y, Sanuki N, Kaneko T. Stereotactic Body Radiation Therapy With a High Maximum Dose Improves Local Control, Cancer-Specific Death, and Overall Survival in Peripheral Early-Stage Non-Small Cell Lung Cancer. Int J Radiat Oncol Biol Phys 2021; 111:143-151. [PMID: 33891980 DOI: 10.1016/j.ijrobp.2021.04.014] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 03/14/2021] [Accepted: 04/12/2021] [Indexed: 12/25/2022]
Abstract
PURPOSE We investigated whether delivery of a high biologically effective dose (BED) to primary tumors affects systemic outcomes of cancer-specific death (CSD) and overall survival (OS) rates after stereotactic body radiation therapy (SBRT) in patients with early-stage non-small cell lung cancer (ES-NSCLC). METHODS AND MATERIALS Among consecutive ES-NSCLC patients treated with SBRT between 2005 and 2019, we retrospectively identified patients who received a prescription of 50 to 60 Gy in 5 fractions with maximum doses of 62.5 to 100 Gy. Patients were categorized by maximum BED within the planning target volume with a threshold dose of 200 Gy. Outcomes were analyzed in all and matched patients. RESULTS Overall, 433 patients were eligible, and 262 and 171 patients were categorized into HighBED and LowBED groups, respectively. After propensity score matching, pairs of 154 patients were selected. Median follow-up times for the HighBED and LowBED groups were 52.3 months (range, 0.8-107.2 months) and 121.6 months (range, 3.0-162.8 months), respectively. The local recurrence rate in the HighBED group was significantly lower than that in the LowBED group (5-year rate, 1.3% and 7.2%; hazard ratio [HR], 0.15; 95% confidence interval [CI], 0.03-0.65; P = .011). Rates of any recurrence and CSD in the HighBED group were significantly lower (5-year any recurrence: 18.1% and 32.1%; HR, 0.52; 95% CI, 0.33-0.83; P = .0058; 5-year CSD: 9.5% and 21.8%; HR, 0.38; 95% CI, 0.20-0.70; P = .002), and OS in the HighBED group was significantly better compared with the LowBED group (5-year rate: 61.7% and 51.8%; HR, 0.71; 95% CI, 0.50-1.00; P = .047). CONCLUSION In patients with peripheral ES-NSCLC, SBRT with a high maximum dose may improve not only local control, but also any recurrence, CSD, and OS rates without increased toxicity. Further trials designed to evaluate whether higher intensity SBRT increases local control rates and contributes to improved CSD and OS outcomes are anticipated.
Collapse
Affiliation(s)
- Yudai Tateishi
- Radiation Oncology Center, Ofuna Chuo Hospital, Kamakura, Kanagawa, Japan
| | - Atsuya Takeda
- Radiation Oncology Center, Ofuna Chuo Hospital, Kamakura, Kanagawa, Japan.
| | - Nobuyuki Horita
- Department of Pulmonology, Yokohama City University Graduate School of Medicine, Yokohama, Japan
| | - Yuichiro Tsurugai
- Radiation Oncology Center, Ofuna Chuo Hospital, Kamakura, Kanagawa, Japan
| | - Takahisa Eriguchi
- Radiation Oncology Center, Ofuna Chuo Hospital, Kamakura, Kanagawa, Japan
| | - Yuichi Kibe
- Radiation Oncology Center, Ofuna Chuo Hospital, Kamakura, Kanagawa, Japan
| | - Naoko Sanuki
- Radiation Oncology Center, Ofuna Chuo Hospital, Kamakura, Kanagawa, Japan
| | - Takeshi Kaneko
- Department of Pulmonology, Yokohama City University Graduate School of Medicine, Yokohama, Japan
| |
Collapse
|
6
|
Manabe Y, Miyakawa A, Kondo T, Yamada Y, Hashimoto S, Ishikura S, Shibamoto Y. Stereotactic body radiotherapy using the forward-planned static-port tomotherapy for lung cancer: a novel planning technique with the newly-developed mode. JOURNAL OF RADIATION RESEARCH 2020; 61:993-998. [PMID: 33210148 PMCID: PMC7674681 DOI: 10.1093/jrr/rraa092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 08/18/2020] [Indexed: 06/11/2023]
Abstract
With the newly-developed static-port forward-planning (FP) mode of tomotherapy, the ratio of the dose of the planning target volume (PTV) periphery to the maximum dose can be easily adjusted by modifying leaf margins when planning stereotactic body radiotherapy (SBRT). The purpose of this study was to evaluate the characteristics of FP plans compared to helical intensity-modulated radiotherapy (IMRT) and helical 3D conformal radiotherapy (3DCRT) plans of SBRT for lung tumors. The three plans were created for 14 tumors in 11 patients. For 13 tumors, 60 Gy in 7.5-Gy fractions was prescribed for a minimum coverage dose of 95% of the PTV (D95). The prescribed isodose line (PIL) was intended to be 60-80% of the maximum dose. Nine angles were used for the FP plans. The median D98 and D50 of the internal target volume for FP, helical-IMRT and helical-3DCRT plans were 70.4, 71.4 and 60.5 Gy, respectively (P < 0.001), and 77.7, 75.7 and 62.3 Gy, respectively (P < 0.0001). The median PIL and the lung volume receiving ≥20 Gy (V20) were 73.4, 73.4 and 94.3%, respectively (P < 0.0001), and 4.7, 4.0 and 5.7%, respectively (P < 0.0001). These parameters were not significantly different between the FP and helical-IMRT plans. The median beam-on times were 238.6, 418.9 and 197.1 s, respectively (P < 0.0001). The FP plans reduced the beam-on time by 43% compared to the helical-IMRT plans. The dose distribution of the FP plans was comparable to that of the helical-IMRT plans. The helical-3DCRT plans could not adjust PIL to be 60-80%.
Collapse
Affiliation(s)
- Yoshihiko Manabe
- Corresponding author. Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mozuho-cho, Mizuho-ku, Nagoya 467-8601, Japan. Tel: +81-52-853-8276; Fax: +81-52-852-5244;
| | - Akifumi Miyakawa
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan
| | - Takuhito Kondo
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan
| | - Yuki Yamada
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan
| | - Seiji Hashimoto
- Department of Radiation Oncology, Nanbu Tokushukai Hospital, 171-1 Hokama, Yaese-cho, Simajiri-gun, Okinawa 901-0493, Japan
| | - Satoshi Ishikura
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan
| | - Yuta Shibamoto
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan
| |
Collapse
|
7
|
Ueda Y, Takakura T, Ota S, Kito S, Sasaki K, Shimizu H, Tatsumi D, Yano S, Nakamura M. Questionnaire survey on treatment planning techniques for lung stereotactic body radiotherapy in Japan. JOURNAL OF RADIATION RESEARCH 2020; 61:104-116. [PMID: 31845998 PMCID: PMC6977596 DOI: 10.1093/jrr/rrz081] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/09/2019] [Revised: 06/07/2019] [Accepted: 11/25/2019] [Indexed: 06/10/2023]
Abstract
This study aimed to obtain details regarding treatment planning techniques for lung stereotactic body radiation therapy (SBRT) employed at each institution in Japan by using a questionnaire survey. An Internet questionnaire survey on SBRT procedures performed in 2016 was conducted by the QA/QC committee of the Japan Society of Medical Physics from April to June 2017. The questionnaire assessed two aspects: the environment for SBRT at each institution and the treatment planning techniques with and without respiratory motion management techniques (RMMT). Of the 309 evaluated responses, 218 institutions had performed SBRT. A total of 186 institutions performed SBRT without RMMT and 139 institutions performed SBRT with RMMT. When respiratory motion was ≥10 mm, 69 institutions applied RMMT. The leading RMMT were breath holding (77 institutions), respiratory gating (49 institutions) and real-time tumor tracking (11 institutions). The most frequently used irradiation technique was 3D conformal radiotherapy, which was used in 145 institutions without RMMT and 119 institutions with RMMT. Computed tomography (CT) images acquired under free breathing were mostly used for dose calculation for patients treated without RMMT. The usage ratio of IMRT/VMAT to SBRT is low in Japan, compared to elsewhere in the world (<20% vs ≥70%). Among the available dose calculation algorithms, superposition convolution was the most frequently used regardless of RMMT; however, 2% of institutions have not yet made heterogeneity corrections. In the prescription setting, about half of the institutions applied point prescriptions. The survey results revealed the most frequently used conditions, which may facilitate standardization of treatment techniques in lung SBRT.
Collapse
Affiliation(s)
- Yoshihiro Ueda
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka-shi, Osaka 541-8567, Japan
| | - Toru Takakura
- Department of Radiation Therapy, Uji-Tokushukai Medical Center, 145 Ishibashi, Makishima-cho, Uji-shi, Kyoto 611-0041, Japan
| | - Seiichi Ota
- Division of Radiological Technology, Department of Medical Technology, University Hospital, Kyoto Prefectural University of Medicine, 465 Kajiicho, Kawaramachi, Hirokoji, Kamigyo-ku, Kyoto 602-8566, Japan
| | - Satoshi Kito
- Department of Radiation Oncology, Tokyo Metropolitan Cancer and Infectious Disease Center Komagome Hospital, 3-18-22 Honkomagome, Bunkyo-ku, Tokyo 113-8677, Japan
| | - Koji Sasaki
- Department of Radiation Therapy Education and Research, Graduate School of Radiological Technology, Gunma Prefectural College of Health Sciences, 323-1 Kamiokimachi, Maebashi-shi, Gunma 371-0052, Japan
| | - Hidetoshi Shimizu
- Department of Radiation Oncology, Aichi Cancer Center Hospital, 1-1 Kanokoden, Chikusa-Ku, Nagoya, Aichi 464-8681, Japan
| | - Daisaku Tatsumi
- Miyakojima IGRT Clinic, 1-16-22, Miyakojimahondori, Miyakojima-ku, Osaka 534-0021, Japan
| | - Shinsuke Yano
- Division of Clinical Radiology Service, Kyoto University Hospital, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507, Japan
| | - Mitsuhiro Nakamura
- Division of Medical Physics, Department of Information Technology and Medical Engineering, Human Health Sciences, Graduate School of Medicine, Kyoto University, 53 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507, Japan
| |
Collapse
|
8
|
Chan M, Wong M, Leung R, Cheung S, Blanck O. Optimizing the prescription isodose level in stereotactic volumetric-modulated arc radiotherapy of lung lesions as a potential for dose de-escalation. Radiat Oncol 2018; 13:24. [PMID: 29426358 PMCID: PMC5807823 DOI: 10.1186/s13014-018-0965-6] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2017] [Accepted: 01/29/2018] [Indexed: 12/11/2022] Open
Abstract
BACKGROUND To derive and exploit the optimal prescription isodose level (PIL) in inverse optimization of volumetric modulated arc radiotherapy (VMAT) as a potential approach to dose de-escalation in stereotactic body radiotherapy for non-small cell lung carcinomas (NSCLC). METHODS For ten patients, inverse Monte Carlo dose optimization was performed to cover 95% PTV by varying prescription isodose lines (PIL) at 60 to 80% and reference 85%. Subsequently, these were re-normalized to the median gross tumor volume dose (GTV-based prescription) to assess the impacts of PTV and normal tissue dose reduction. RESULTS With PTV-based prescription, GTV mean dose was much higher with the optimized PIL at 60% with significant reduction of normal lung receiving 30 to 10 Gy (V 30-10Gy ), and observable but insignificant dose reduction to spinal cord, esophagus, ribs, and others compared with 85% PIL. Mean doses to the normal lung between PTV and GTV was higher with 60-70% PIL than 85%. The dose gradient index was 5.0 ± 1.1 and 6.1 ± 1.4 for 60 and 85% PIL (p < 0.05), respectively. Compared with the reference 85% PIL plan using PTV-base prescription, significant decreases of all normal tissue doses were observed with 60% and 70% PIL by GTV-based prescription. Yet, the resulting biological effective (BED) mean doses of PTV remain sufficiently high, ranging 104.2 to 116.9 Gy α/β = 10. CONCLUSIONS Optimizing the PIL with VMAT has notable advantage of improving the dosimetric quality of lung SBRT and offers the potential of dose de-escalation for surrounding tissues while increasing the GTV dose simultaneously. The clinical implication of re-normalizing plans from PTV-prescription at 60-70% to the GTV median dose requires further investigations.
Collapse
Affiliation(s)
- Mark Chan
- University Medical Center Schleswig–Holstein, Campus Kiel, Department for Radiation Oncology, Arnold–Heller–Straße 3, Haus 50, Karl–Lennert–Krebscentrum Nord, 24105 Kiel, Germany
- Imperial College London Healthcare NHS Trust, Department of Radiation Physics, London, UK
| | - Matthew Wong
- Tuen Mun Hospital, Department of Clinical Oncology, Special Administrative Region of China, Hong Kong, Hong Kong, Special Administrative Region of China
| | - Ronnie Leung
- Tuen Mun Hospital, Department of Clinical Oncology, Special Administrative Region of China, Hong Kong, Hong Kong, Special Administrative Region of China
| | - Steven Cheung
- Tuen Mun Hospital, Department of Clinical Oncology, Special Administrative Region of China, Hong Kong, Hong Kong, Special Administrative Region of China
| | - Oliver Blanck
- University Medical Center Schleswig–Holstein, Campus Kiel, Department for Radiation Oncology, Arnold–Heller–Straße 3, Haus 50, Karl–Lennert–Krebscentrum Nord, 24105 Kiel, Germany
- Saphir Radiosurgery Center Northern Germany, Güstrow, Germany
| |
Collapse
|
9
|
Giglioli FR, Clemente S, Esposito M, Fiandra C, Marino C, Russo S, Strigari L, Villaggi E, Stasi M, Mancosu P. Frontiers in planning optimization for lung SBRT. Phys Med 2017; 44:163-170. [PMID: 28566240 DOI: 10.1016/j.ejmp.2017.05.064] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2016] [Revised: 05/19/2017] [Accepted: 05/22/2017] [Indexed: 12/25/2022] Open
Abstract
Emerging data are showing the safety and the efficacy of Stereotactic Body Radiation therapy (SBRT) in lung cancer management. In this context, the very high doses delivered to the Planning Target Volume, make the planning phase essential for achieving high dose levels conformed to the shape of the target in order to have a good prognosis for tumor control and to avoid an overdose in relevant healthy adjacent tissue. In this non-systematic review we analyzed the technological and the physics aspects of SBRT planning for lung cancer. In particular, the aims of the study were: (i) to evaluate prescription strategies (homogeneous or inhomogeneous), (ii) to outline possible geometrical solutions by comparing the dosimetric results (iii) to describe the technological possibilities for a safe and effective treatment, (iv) to present the issues concerning radiobiological planning and the automation of the planning process.
Collapse
Affiliation(s)
| | | | | | - Christian Fiandra
- Dep. of Oncology Radiation Oncology Unit, University of Torino, Italy
| | | | | | - Lidia Strigari
- Laboratory of Medical Physics and Expert Systems, Regina Elena National Cancer, Institute IFO, Rome, Italy
| | | | - Michele Stasi
- Medical Physics Dept., Azienda Ospedaliera Ordine Mauriziano di Torino, Torino, Italy
| | - Pietro Mancosu
- Medical Physics Unit of Radiotherapy Dept., Humanitas Clinical and Research Hospital, Rozzano (MI), Italy
| |
Collapse
|
10
|
Iwata H, Ishikura S, Murai T, Iwabuchi M, Inoue M, Tatewaki K, Ohta S, Yokota N, Shibamoto Y. A phase I/II study on stereotactic body radiotherapy with real-time tumor tracking using CyberKnife based on the Monte Carlo algorithm for lung tumors. Int J Clin Oncol 2017; 22:706-714. [DOI: 10.1007/s10147-017-1123-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2016] [Accepted: 04/05/2017] [Indexed: 12/25/2022]
|
11
|
Takeda A, Sanuki N, Tsurugai Y, Oku Y, Aoki Y. Stereotactic body radiotherapy for patients with oligometastases from colorectal cancer: risk-adapted dose prescription with a maximum dose of 83-100 Gy in five fractions. JOURNAL OF RADIATION RESEARCH 2016; 57:400-5. [PMID: 26983981 PMCID: PMC4973648 DOI: 10.1093/jrr/rrw029] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2015] [Accepted: 02/11/2016] [Indexed: 05/09/2023]
Abstract
We previously reported that the local control of pulmonary metastases from colorectal cancer (CRC) following stereotactic body radiotherapy (SBRT) with moderate prescription dose was relatively worse. We investigated the treatment outcomes and toxicities of patients with oligometastases from CRC treated by SBRT using risk-adapted, very high- and convergent-dose regimens. Among patients referred for SBRT from August 2011 to January 2015, those patients were extracted who had liver or pulmonary metastases from CRC, and they were treated with a total dose of 50-60 Gy in five fractions prescribed to the 60% isodose line of the maximum dose covering the surface of the planning target volume. Concurrent administration of chemotherapy was not admitted during SBRT, while neoadjuvant or adjuvant chemotherapy was allowed. A total of 21 patients (12 liver, 9 lung) with 28 oligometastases were evaluated. The median follow-up duration was 27.5 months (range: 6.5-43.3 months). Four patients were treated with SBRT as a series of initial treatments, and 17 patients were treated after recurrent oligometastases. The local control rates at 1 and 2 years from the start of SBRT were 100%. The disease-free and actuarial overall survival rates were 62% and 55%, and 79% and 79%, respectively. No severe toxicities (≥grade 3) occurred during follow-up. The outcomes following high-dose SBRT were excellent. This treatment can provide an alternative to the surgical resection of oligometastases from CRC. Prospective studies are needed to validate the effectiveness of SBRT.
Collapse
Affiliation(s)
- Atsuya Takeda
- Radiation Oncology Center, Ofuna Chuo Hospital, Kamakura, Kanagawa, Japan
| | - Naoko Sanuki
- Radiation Oncology Center, Ofuna Chuo Hospital, Kamakura, Kanagawa, Japan
| | - Yuichiro Tsurugai
- Radiation Oncology Center, Ofuna Chuo Hospital, Kamakura, Kanagawa, Japan
| | - Yohei Oku
- Radiation Oncology Center, Ofuna Chuo Hospital, Kamakura, Kanagawa, Japan
| | - Yousuke Aoki
- Radiation Oncology Center, Ofuna Chuo Hospital, Kamakura, Kanagawa, Japan
| |
Collapse
|
12
|
Dose-Escalated Stereotactic Body Radiotherapy (SBRT) as a Salvage Treatment for Two Cases with Relapsed Peripheral Lung Cancer After Initial SBRT. J Thorac Oncol 2016. [PMID: 26200281 DOI: 10.1097/jto.0000000000000543] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
13
|
Giglioli FR, Strigari L, Ragona R, Borzì GR, Cagni E, Carbonini C, Clemente S, Consorti R, El Gawhary R, Esposito M, Falco MD, Fedele D, Fiandra C, Frassanito MC, Landoni V, Loi G, Lorenzini E, Malisan MR, Marino C, Menghi E, Nardiello B, Nigro R, Oliviero C, Pastore G, Quattrocchi M, Ruggieri R, Redaelli I, Reggiori G, Russo S, Villaggi E, Casati M, Mancosu P. Lung stereotactic ablative body radiotherapy: A large scale multi-institutional planning comparison for interpreting results of multi-institutional studies. Phys Med 2016; 32:600-6. [DOI: 10.1016/j.ejmp.2016.03.015] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/24/2015] [Revised: 03/15/2016] [Accepted: 03/19/2016] [Indexed: 12/25/2022] Open
|
14
|
Zhao J, Yorke ED, Li L, Kavanagh BD, Li XA, Das S, Miften M, Rimner A, Campbell J, Xue J, Jackson A, Grimm J, Milano MT, Spring Kong FM. Simple Factors Associated With Radiation-Induced Lung Toxicity After Stereotactic Body Radiation Therapy of the Thorax: A Pooled Analysis of 88 Studies. Int J Radiat Oncol Biol Phys 2016; 95:1357-1366. [PMID: 27325482 DOI: 10.1016/j.ijrobp.2016.03.024] [Citation(s) in RCA: 120] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2015] [Revised: 02/04/2016] [Accepted: 03/17/2016] [Indexed: 12/13/2022]
Abstract
PURPOSE To study the risk factors for radiation-induced lung toxicity (RILT) after stereotactic body radiation therapy (SBRT) of the thorax. METHODS AND MATERIALS Published studies on lung toxicity in patients with early-stage non-small cell lung cancer (NSCLC) or metastatic lung tumors treated with SBRT were pooled and analyzed. The primary endpoint was RILT, including pneumonitis and fibrosis. Data of RILT and risk factors were extracted from each study, and rates of grade 2 to 5 (G2+) and grade 3 to 5 (G3+) RILT were computed. Patient, tumor, and dosimetric factors were analyzed for their correlation with RILT. RESULTS Eighty-eight studies (7752 patients) that reported RILT incidence were eligible. The pooled rates of G2+ and G3+ RILT from all 88 studies were 9.1% (95% confidence interval [CI]: 7.15-11.4) and 1.8% (95% CI: 1.3-2.5), respectively. The median of median tumor sizes was 2.3 (range, 1.4-4.1) cm. Among the factors analyzed, older patient age (P=.044) and larger tumor size (the greatest diameter) were significantly correlated with higher rates of G2+ (P=.049) and G3+ RILT (P=.001). Patients with stage IA versus stage IB NSCLC had significantly lower risks of G2+ RILT (8.3% vs 17.1%, odds ratio = 0.43, 95% CI: 0.29-0.64, P<.0001). Among studies that provided detailed dosimetric data, the pooled analysis demonstrated a significantly higher mean lung dose (MLD) (P=.027) and V20 (P=.019) in patients with G2+ RILT than in those with grade 0 to 1 RILT. CONCLUSIONS The overall rate of RILT is relatively low after thoracic SBRT. Older age and larger tumor size are significant adverse risk factors for RILT. Lung dosimetry, specifically lung V20 and MLD, also significantly affect RILT risk.
Collapse
Affiliation(s)
- Jing Zhao
- Department of Radiation Oncology, GRU Cancer Center/Medical College of Georgia, Georgia Regents University, Augusta, Georgia; Department of Oncology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Ellen D Yorke
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Ling Li
- Department of Radiation Oncology, GRU Cancer Center/Medical College of Georgia, Georgia Regents University, Augusta, Georgia; Department of Shanghai Cancer Hospital, Fudan University, Shanghai, China
| | - Brian D Kavanagh
- Department of Radiation Oncology, University of Colorado, Denver, Colorado
| | - X Allen Li
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Shiva Das
- Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina
| | - Moyed Miften
- Department of Radiation Oncology, University of Colorado, Denver, Colorado
| | - Andreas Rimner
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York City, New York
| | - Jeffrey Campbell
- Department of Radiation Oncology, GRU Cancer Center/Medical College of Georgia, Georgia Regents University, Augusta, Georgia
| | - Jinyu Xue
- Department of Radiation Oncology, MD Anderson Cancer Center at Cooper, Camden, New Jersey
| | - Andrew Jackson
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Jimm Grimm
- Bott Cancer Center, Holy Redeemer Hospital, Meadowbrook, Pennsylvania
| | - Michael T Milano
- Department of Radiation Oncology, University of Rochester, Rochester, New York
| | - Feng-Ming Spring Kong
- Department of Radiation Oncology, GRU Cancer Center/Medical College of Georgia, Georgia Regents University, Augusta, Georgia; Currently at Department of Radiation Oncology, Simon Cancer Center, Indiana University Medical School, Indianapolis, Indiana.
| |
Collapse
|
15
|
Dosimetric comparison of lung stereotactic body radiotherapy treatment plans using averaged computed tomography and end-exhalation computed tomography images: Evaluation of the effect of different dose-calculation algorithms and prescription methods. Med Dosim 2016; 41:305-309. [DOI: 10.1016/j.meddos.2016.07.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2016] [Revised: 04/13/2016] [Accepted: 07/16/2016] [Indexed: 12/25/2022]
|
16
|
Comparison of pencil beam–based homogeneous vs inhomogeneous target dose planning for stereotactic body radiotherapy of peripheral lung tumors through Monte Carlo–based recalculation. Med Dosim 2015; 40:248-55. [DOI: 10.1016/j.meddos.2015.02.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2014] [Revised: 12/28/2014] [Accepted: 02/02/2015] [Indexed: 11/22/2022]
|
17
|
Toxicities of Organs at Risk in the Mediastinal and Hilar Regions Following Stereotactic Body Radiotherapy for Centrally Located Lung Tumors. J Thorac Oncol 2014; 9:1370-6. [DOI: 10.1097/jto.0000000000000260] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
18
|
Ohtakara K, Hoshi H. Target volume geometric change and/or deviation from the cranium during fractionated stereotactic radiotherapy for brain metastases: potential pitfalls in image guidance based on bony anatomy alignment. J Med Imaging Radiat Oncol 2014; 58:729-36. [PMID: 24935347 DOI: 10.1111/1754-9485.12194] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2014] [Accepted: 05/13/2014] [Indexed: 11/27/2022]
Abstract
INTRODUCTION This study sought to evaluate the potential geometrical change and/or displacement of the target relative to the cranium during fractionated stereotactic radiotherapy (FSRT) for treating newly developed brain metastases. METHODS For 16 patients with 21 lesions treated with image-guided frameless FSRT in 5 or 10 fractions using a 6-degree-of-freedom image guidance system-integrated platform, the unenhanced computed tomography or T2-weighted magnetic resonance images acquired until the completion of FSRT were fused to the planning image datasets for comparison. Significant change was defined as ≥3-mm change in the tumour diameter or displacement of the tumour centroid. RESULTS FSRT was started 1 day after planning image acquisition. Tumour shrinkage, deviation and both were observed in 2, 1 and 1 of the 21 lesions, respectively, over a period of 7-13 days. Tumour shrinkage or deviation resulted in an increase or decrease in the marginal dose to the tumour, respectively, and a substantial increase in the irradiated volume for the surrounding tissue irrespective of the pattern of alteration. No obvious differences in the clinical and treatment characteristics were noted among the populations with or without significant changes in tumour volume or position. CONCLUSION Target deformity and/or deviation can unexpectedly occur even during relatively short-course FSRT, inevitably leading to a gradual discrepancy between the planned and actually delivered doses to the tumour and surrounding tissue. To appropriately weigh the treatment outcome against the planned dose distribution, target deformity and/or deviation should also be considered in addition to the immobilisation accuracy, as image guidance with bony anatomy alignment does not necessarily guarantee accurate target localisation until completion of FSRT.
Collapse
Affiliation(s)
- Kazuhiro Ohtakara
- Department of Radiology, Gifu University Graduate School of Medicine, Gifu, Japan; Division of Radiation Oncology, Gifu University Hospital, Gifu, Japan
| | | |
Collapse
|
19
|
Maximum Standardized Uptake Value on FDG-PET Is a Strong Predictor of Overall and Disease-Free Survival for Non–Small-Cell Lung Cancer Patients after Stereotactic Body Radiotherapy. J Thorac Oncol 2014; 9:65-73. [DOI: 10.1097/jto.0000000000000031] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
20
|
Stereotactic ablative body radiation therapy with dynamic conformal multiple arc therapy for liver tumors: Optimal isodose line fitting to the planning target volume. Pract Radiat Oncol 2014; 4:e7-e13. [DOI: 10.1016/j.prro.2013.04.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2013] [Revised: 03/07/2013] [Accepted: 04/04/2013] [Indexed: 12/31/2022]
|
21
|
Eriguchi T, Takeda A, Oku Y, Ishikura S, Kimura T, Ozawa S, Nakashima T, Matsuo Y, Nakamura M, Matsumoto Y, Yamazaki S, Sanuki N, Ito Y. Multi-institutional comparison of treatment planning using stereotactic ablative body radiotherapy for hepatocellular carcinoma - benchmark for a prospective multi-institutional study. Radiat Oncol 2013; 8:113. [PMID: 23641879 PMCID: PMC3653723 DOI: 10.1186/1748-717x-8-113] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2013] [Accepted: 04/30/2013] [Indexed: 12/20/2022] Open
Abstract
Introduction Several single institution phase I and phase II trials of stereotactic ablative body radiotherapy (SABR) for liver tumors have reported promising results and high local control rates of over 90%. However, there are wide variations in dose and fractionation due to different prescription policies and treatment methods across SABR series that have been published to date. This study aims to assess and minimize inter-institutional variations in treatment planning using SABR for hepatocellular carcinoma (HCC) in preparation for a prospective multi-institutional study. Methods Four institutions (A-D) participated in this study. Each institution was provided with data from four cases, including planning and diagnostic CT images and clinical information, and asked to implement three plans (a practice plan and protocol plans 1 and 2). Practice plans were established based on the current treatment protocols at each institution. In protocol plan 1, each institution was instructed to prescribe 40 Gy in five fractions within 95% of the planning target volume (PTV). After protocol plan 1 was evaluated, we made protocol plan 2, The additional regulation to protocol plan 1 was that 40 Gy in five fractions was prescribed to a 70% isodose line of the global maximum dose within the PTV. Planning methods and dose volume histograms (DVHs) including the median PTV D50 (Dm50) and the median normal liver volume that received 20 Gy or higher (Vm20) were compared. Results In the practice plan, Dm50 was 48.4 Gy (range, 43.6-51.2 Gy). Vm20 was 15.9% (range, 12.2-18.9%). In protocol plan 1, the Dm50 at institution A was higher (51.2 Gy) than the other institutions (42.0-42.2 Gy) due to differences in dose specifications. In protocol plan 2, variations in DVHs were reduced. The Dm50 was 51.9 Gy (range, 51.0-53.1 Gy), and the Vm20 was 12.3% (range, 10.4-13.2%). The homogeneity index was nearly equivalent at all institutions. Conclusions There were notable inter-institutional differences in practice planning using SABR to treat HCC. The range of PTV and normal liver DVH values was reduced when the dose was prescribed to an isodose line within the PTV. In multi-institutional studies, detailed dose specifications based on collaboration are necessary.
Collapse
|