1
|
Duffton A, Li W, Forde E. The Pivotal Role of the Therapeutic Radiographer/Radiation Therapist in Image-guided Radiotherapy Research and Development. Clin Oncol (R Coll Radiol) 2020; 32:852-860. [PMID: 33087296 DOI: 10.1016/j.clon.2020.09.009] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 08/21/2020] [Accepted: 09/22/2020] [Indexed: 12/24/2022]
Abstract
The ability to personalise radiotherapy to fit the individual patient and their diagnosis has been realised through technological advancements. There is now more opportunity to utilise these technologies and deliver precision radiotherapy for more patients. Image-guided radiotherapy (IGRT) has enabled users to safely and accurately plan, treat and verify complex cases; and deliver a high dose to the target volume, while minimising dose to normal tissue. Rapid changes in IGRT have required a multidisciplinary team (MDT) approach, carefully deciding optimum protocols to achieve clinical benefit. Therapeutic radiographer/radiation therapists (RTTs) play a pivotal role in this MDT. There is already a great deal of evidence that illustrates the contribution of RTTs in IGRT development; implementation; quality assurance; and maintaining training and competency programmes. Often this has required the RTT to undertake additional roles and responsibilities. These publications show how the profession has evolved, expanding the scope of practice. There are now more opportunities for RTT-led IGRT research. This is not only undertaken in the more traditional aspects of practice, but in recent times, more RTTs are becoming involved in imaging biomarkers research and radiomic analysis. The aim of this overview is to describe the RTT contribution to the ongoing development of IGRT and to showcase some of the profession's involvement in IGRT research.
Collapse
Affiliation(s)
- A Duffton
- Department of Radiotherapy, Beatson West of Scotland Cancer Centre, Glasgow, UK.
| | - W Li
- University of Toronto, Toronto, Ontario, Canada; Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada
| | - E Forde
- Applied Radiation Therapy Trinity, Discipline of Radiation Therapy, Trinity College Dublin, The University of Dublin, Dublin, Ireland
| |
Collapse
|
2
|
Fukao M, Okamura K, Sabu S, Akino Y, Arimura T, Inoue S, Kado R, Seo Y. Repositioning accuracy of a novel thermoplastic mask for head and neck cancer radiotherapy. Phys Med 2020; 74:92-99. [PMID: 32450542 DOI: 10.1016/j.ejmp.2020.05.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2019] [Revised: 03/05/2020] [Accepted: 05/08/2020] [Indexed: 10/24/2022] Open
Abstract
PURPOSE The aim of this study was to assess the reproducibility of patient shoulder position immobilized with a novel and innovative prototype mask (E-Frame, Engineering System). METHODS The E-frame mask fixes both shoulders and bisaxillary regions compared with that of a commercial mask (Type-S, CIVCO). Thirteen and twelve patients were immobilized with the Type-S and E-Frame mask systems, respectively. For each treatment fraction, cone-beam CT (CBCT) images of the patient were acquired and retrospectively analyzed. The CBCT images were registered to the planning CT based on the cervical spine, and then the displacements of the acromial extremity of the clavicle were measured. RESULTS The systematic and random errors between the two mask systems were evaluated. The differences of the systematic errors between the two mask systems were not statistically significant. The mean random errors in the three directions (AP, SI and LR) were 2.7 mm, 3.1 mm and 1.5 mm, respectively for the Type-S mask, and 2.8 mm 2.5 mm and 1.4 mm, respectively for the E-Frame mask. The random error of the E-Frame masks in the SI direction was significantly smaller than that of the Type-S. The number of cases showing displacements exceeding 10 mm in the SI direction for at least one fraction was eight (61% of 13 cases) and three (25% of 12 cases) for Type-S and E-Frame masks, respectively. CONCLUSIONS The E-Frame masks reduced the random displacements of patient's shoulders in the SI direction, effectively preventing large shoulder shifts that occurred frequently with Type-S masks.
Collapse
Affiliation(s)
- Mari Fukao
- Department of Medical Technology, Osaka University Hospital, 2-15, Yamadaoka, Suita, Osaka 565-0871, Japan.
| | - Keita Okamura
- Department of Medical Technology, Osaka University Hospital, 2-15, Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Shotaro Sabu
- Department of Medical Technology, Osaka University Hospital, 2-15, Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Yuichi Akino
- Oncology Center, Osaka University Hospital, 2-2 (D10), Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Takehiro Arimura
- Department of Medical Technology, Osaka University Hospital, 2-15, Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Shinichi Inoue
- Department of Medical Technology, Osaka University Hospital, 2-15, Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Ryoko Kado
- Department of Nursing, Osaka University Hospital, 2-15, Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Yuji Seo
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 (D10), Yamadaoka, Suita, Osaka 565-0871, Japan
| |
Collapse
|
3
|
A comparative study between open-face and closed-face masks for head and neck cancer (HNC) in radiation therapy. Rep Pract Oncol Radiother 2020; 25:382-388. [PMID: 32322177 DOI: 10.1016/j.rpor.2020.03.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 12/09/2019] [Accepted: 03/12/2020] [Indexed: 11/20/2022] Open
Abstract
Aim To determine the setup reproducibility in the radiation treatment of Head and Neck (HN) patients using open face head and shoulder masks (OHSM) with customized headrest (CHR) versus standard closed head and shoulder masks (CHSM) and to determine the patient's level of comfort and satisfaction for both masks. Methods Forty patients were prospectively randomized into two groups using simple random sampling. Group 1 was assigned with CHSMs, immobilized with a standard HR (SHR) while Group 2 was assigned with OHSMs, and immobilized with CHR. Cone beam computed tomography (CBCT) was taken the first 3 days, followed by weekly CBCT (prior treatment) with results registered to the planning CT to determine translational and rotational inter-fraction shifts and to verify accuracy. Mean (M) and standard deviation (SD) of the systematic and random setup errors of the 2 arms in the translational and rotational directions were analyzed, using Independent t-test and Mann-Whitney U test. Patient comfort was measured using a Likert questionnaire. Results The vertical, lateral, longitudinal and Z/roll rotational shifts were not significantly different between the two masks. X/yaw and Y/pitch rotational shifts were significantly greater in Group 2 versus Group 1, for both systematic (p = 0.009 and 0.046, respectively) and random settings (p = 0.016 and 0.020) but still within three degrees. Patients reported higher neck and shoulder comfort (p = 0.020) and overall satisfaction (p = 0.026) using the OHSM with the CHR versus the CHSM with the SHR during CT simulation. Conclusion Open masks provide comparable yet comfortable immobilization to closed masks for HN radiotherapy.
Collapse
|
4
|
van Beek S, Jonker M, Hamming-Vrieze O, Al-Mamgani A, Navran A, Remeijer P, van de Kamer JB. Protocolised way to cope with anatomical changes in head & neck cancer during the course of radiotherapy. Tech Innov Patient Support Radiat Oncol 2019; 12:34-40. [PMID: 32095553 PMCID: PMC7033784 DOI: 10.1016/j.tipsro.2019.11.001] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2019] [Revised: 10/14/2019] [Accepted: 11/01/2019] [Indexed: 12/01/2022] Open
Abstract
INTRODUCTION During a course of radiotherapy for head-and-neck-cancer (HNC), non-rigid anatomical changes can be observed on daily Cone Beam CT (CBCT). To objectify responses to these changes, we use a decision support system (traffic light protocol). Action levels orange and red may lead to re-planning. The purpose of this study was to evaluate how often re-planning was done for non-rigid anatomical changes, which anatomical changes led to re-planning and in which subgroups of patients treatment adaptation was deemed necessary. MATERIALS AND METHODS A consecutive series of 388 HNC patients were retrospectively selected using the digital log of CBCT scans. The logs were analyzed for the number of new plans on an original planning CT scan (O-pCT) or a new pCT scan (N-pCT). Reasons for re-planning were categorized into: target volume increase/decrease, body contour decrease/increase and local shift of target volume. Subgroup analysis was performed to investigate relative differences of re-planning between treatment modalities. RESULTS For 33 patients the treatment plan was adapted due to anatomical changes, resulting in 37 new plans in total. Re-planning on a N-pCT with complete re-delineation was done 22 times. In fifteen cases a new plan was created after adjustment of contours on the O-pCT. Main reasons for re-planning were target volume increase, body contour decrease and local shifts of target volume. Most re-planning (23%) was seen in patients treated with chemoradiotherapy. CONCLUSION Visual detection of anatomical changes on CBCT during treatment of HNC, results in re-planning in 1 out of 10 patients.
Collapse
|