1
|
Hasegawa T, Tsuboi M, Takahashi Y, Endo A, Gotoh Y. Feasibility of an antegrade-retrograde single-sheath inverse technique via vertical puncture in dysfunctional hemodialysis arteriovenous fistula angioplasty. CVIR Endovasc 2024; 7:69. [PMID: 39302567 DOI: 10.1186/s42155-024-00480-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2024] [Accepted: 09/05/2024] [Indexed: 09/22/2024] Open
Abstract
BACKGROUND Stenosis resulting in dysfunctional dialysis access may occur simultaneously on the anastomotic and central venous side. The purpose of this study was to retrospectively evaluate the feasibility of a single sheath inverse technique using the vertical puncture approach to perform bidirectional transvenous percutaneous transluminal angioplasty (PTA) from a single sheath for such dialysis access stenoses. MATERIALS AND METHODS Twenty patients (26 cases; 13 males; median age, 74 [range: 50-89] years) who underwent PTA using the sheath inverse technique for dysfunctional arteriovenous fistula stenoses between April 2019 and June 2023 were included. All procedures were performed in an outpatient setting. A 4-cm sheath (4Fr, four cases; 5Fr, 19 cases; 6Fr, three cases) was inserted by vertical puncture through a cutaneous vein in the forearm (20 cases) or upper arm (six cases). After treating one side of the lesion, the sheath was reversed to treat the lesion on the opposite side. The vessel diameter at the sheath insertion site, the success rate of sheath inversion, the number of PTA balloon catheters used, the PTA success rate, adverse events, and primary and secondary patency rates up to one year after PTA were evaluated. RESULTS The median diameter at the sheath indwelling site was 5.2 (range: 3.6-9.5) mm, and sheath inversion was successful in all cases, eliminating the need to place an additional sheath at another site for contralateral stricture treatment. The number of balloon catheters used was one and two in 17 (65%) and eight cases (31%), respectively, and three in one case wherein a drug-coated balloon was used. PTA was successful in all cases and major complications were not observed. However, in one case wherein a sheath had to be placed at the arterial needle puncture site, the skin was hard, leading to difficulty in inversion, and transient venous spasm occurred post-inversion. The primary patency rates at 3, 6 and 12 months after the PTA were 87.5%, 41.7%, and 20.8%, respectively. The secondary patency rates at 6 and 12 months were 100% and 75%, respectively. CONCLUSION The single-sheath inverse technique for arteriovenous fistulas was feasible without sheath withdrawal.
Collapse
Affiliation(s)
- Tetsuya Hasegawa
- Department of Diagnostic Radiology, Japanese Red Cross Ishinomaki Hospital, 71, Nishimichishita, Hebita, Ishinomaki-shi, Miyagi, 986-8522, Japan.
- Department of Diagnostic Radiology, Osaki Citizen Hospital, 3-8-1, Honami, Furukawa, Osaki-shi, Miyagi, 989-6183, Japan.
| | - Masahiro Tsuboi
- Department of Diagnostic Radiology, Osaki Citizen Hospital, 3-8-1, Honami, Furukawa, Osaki-shi, Miyagi, 989-6183, Japan
| | - Yuki Takahashi
- Department of Diagnostic Radiology, Osaki Citizen Hospital, 3-8-1, Honami, Furukawa, Osaki-shi, Miyagi, 989-6183, Japan
| | - Akira Endo
- Department of Diagnostic Radiology, Osaki Citizen Hospital, 3-8-1, Honami, Furukawa, Osaki-shi, Miyagi, 989-6183, Japan
| | - Yasuo Gotoh
- Department of Radiology, Shunt Clinic Sendai-Higashi, 2-17-25, Higashi Sendai, Miyagino-ku, Sendai-shi, Miyagi, 983-0833, Japan
| |
Collapse
|
2
|
Kamada H, Sato T, Oguro S, Ota H, Takase K. Two-session embolization of portosystemic shunt presenting with hepatic encephalopathy via transvenous and trans-paraumbilical approaches: A case report. Radiol Case Rep 2024; 19:2112-2116. [PMID: 38645534 PMCID: PMC11026921 DOI: 10.1016/j.radcr.2024.02.057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 02/11/2024] [Accepted: 02/15/2024] [Indexed: 04/23/2024] Open
Abstract
We describe the endovascular embolization of a 65-year-old man with chronic hepatic encephalopathy. A contrast-enhanced computed tomography demonstrated a splenorenal shunt and a recanalized paraumbilical vein as a continuous portal shunt connecting the left branch of the portal vein and the right common femoral vein. A 2-session embolization was performed for the splenorenal shunt. First, the transvenous approach was used for coil embolization of the splenorenal shunt. It was difficult to advance the catheter system to the embolization site, and it was unstable during coil placement. Second, the paraumbilical venous approach was used to place additional coils. The catheter system had good maneuverability and easily reached the embolization site. Additionally, the stable system allowed for densely packed additional coil implantations. This report demonstrated the paraumbilical venous approach's effectiveness in catheter maneuverability and system stability during coil embolization.
Collapse
Affiliation(s)
- Hiroki Kamada
- Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Japan
| | - Tomomi Sato
- Department of Radiology, Tohoku Medical and Pharmaceutical University Hospital, Sendai, Japan
| | - Sota Oguro
- Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Japan
| | - Hideki Ota
- Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Japan
| | - Kei Takase
- Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Japan
| |
Collapse
|
3
|
Mundhra S, Mohta S, Gamanagatti S, Sharma S, Hemachandran N, Saraya A. Recanalized Paraumbilical Vein Leading to Hepatic Myelopathy Causing Spastic Paraparesis in a Patient with Chronic Liver Disease. J Clin Exp Hepatol 2023; 13:372-376. [PMID: 36950497 PMCID: PMC10025748 DOI: 10.1016/j.jceh.2022.09.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2022] [Accepted: 09/27/2022] [Indexed: 11/11/2022] Open
Abstract
A 34-year-old male visited our hospital with complaints of recurrent episodes of altered behavior since past 6 months along with difficulty in walking since past 3 months. He was diagnosed of chronic liver disease in the past. Examination revealed spasticity and brisk deep tendon reflexes in both the lower limbs. His blood investigations and spinal cord imaging was normal. Based on his clinical features, a possibility of portosystemic shunting leading to portosystemic encephalopathy (PSE) and shunt myelopathy was suspected. A computed tomography portography showed a recanalized paraumblical vein draining portal blood into external iliac veins. Patient underwent shunt occlusion (Figure- 2). One month after the procedure, while there was no recurrence of symptoms of PSE, those of myelopathy remained unchanged. Shunt myelopathy is a rare complication of spontaneous or iatrogenic portosystemic shunts. Unlike PSE, the management of shunt myelopathy is uncertain due to limited evidence. Limited evidence suggests reversal of myelopathy after early shunt occlusion, highlighting the irreversible changes that may set in spinal cord due to delayed diagnosis. Our case highlights an important but a rare complication of portosystemic shunting in chronic liver disease which should be kept in mind if these patients develop symptoms attributable to spinal cord disease.
Collapse
Affiliation(s)
- Sandeep Mundhra
- Department of Gastroenterology and Human Nutrition Unit, All India Institute of Medical Sciences, New Delhi, 110029, India
| | - Srikant Mohta
- Department of Gastroenterology and Human Nutrition Unit, All India Institute of Medical Sciences, New Delhi, 110029, India
| | - Shivanand Gamanagatti
- Department of Radiodiagnosis, All India Institute of Medical Sciences, New Delhi, 110029, India
| | - Sanchit Sharma
- Department of Gastroenterology and Human Nutrition Unit, All India Institute of Medical Sciences, New Delhi, 110029, India
| | - Naren Hemachandran
- Department of Radiodiagnosis, All India Institute of Medical Sciences, New Delhi, 110029, India
| | - Anoop Saraya
- Department of Gastroenterology and Human Nutrition Unit, All India Institute of Medical Sciences, New Delhi, 110029, India
| |
Collapse
|