Feng A, Gu H, Chen H, Shao Y, Wang H, Duan Y, Huang Y, Zhou T, Xu Z. Account for the Full Extent of Esophagus Motion in Radiation Therapy Planning: A Preliminary Study of the IRV of the Esophagus. Front Oncol 2021; 11:734552. [PMID: 34900685 PMCID: PMC8656362 DOI: 10.3389/fonc.2021.734552] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Accepted: 10/28/2021] [Indexed: 11/23/2022] Open
Abstract
Objective Accounting for esophagus motion in radiotherapy planning is an important basis for accurate assessment of toxicity. In this study, we calculated how much the delineations of the esophagus should be expanded based on three-dimensional (3D) computed tomography (CT), four-dimensional (4D) average projection (AVG), and maximum intensity projection (MIP) scans to account for the full extent of esophagus motion during 4D imaging acquisition. Methods and Materials The 3D and 4D CT scans of 20 lung cancer patients treated with conventional radiotherapy and 20 patients treated with stereotactic ablative radiation therapy (SBRT) were used. Radiation oncologists contoured the esophagus on the 3DCT, AVG, MIP and 25% exhale scans, and the combination of the esophagus in every phase of 4DCT. The union of all 4D phase delineations (U4D) represented the full extent of esophagus motion during imaging acquisition. Surface distances from U4D to 3D, AVG, and MIP volumes were calculated. Distances in the most extreme surface points (1.5 cm most superoinferior, 10% most right/left/anteroposterior) were used to derive margins accounting only for systematic (delineation) errors. Results Esophagus delineations on the MIP were the closest to the full extent of motion, requiring only 6.9 mm margins. Delineations on the AVG and 3D scans required margins up to 7.97 and 7.90 mm, respectively. The largest margins were for the inferior, right, and anterior aspects for the delineations on the 3D, AVG, and MIP scans, respectively. Conclusion Delineations on 3D, AVG, or MIP scans required extensions for representing the esophagus’s full extent of motion, with the MIP requiring the smallest margins. Research including daily imaging to determine the random components for the margins and dosimetric measurements to determine the relevance of creating a planning organ at risk volume (PRV) of the esophagus is required.
Collapse
Affiliation(s)
- Aihui Feng
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Hengle Gu
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Hua Chen
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Yan Shao
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Hao Wang
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Yanhua Duan
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Ying Huang
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Tao Zhou
- Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China
| | - Zhiyong Xu
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
2
|
Dose volume histogram metrics and tumour control probability modelling in locally advanced non-small-cell lung cancer: average intensity dataset versus individual four-dimensional CT phases. JOURNAL OF RADIOTHERAPY IN PRACTICE 2020. [DOI: 10.1017/s146039692000076x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
AbstractAim:This work compares dose-volume constraints (DVCs) and tumour control predictions based on the average intensity projection (AVIP) to those on each phase of the four-dimensional computed tomography.Materials and methods:In this prospective study plans generated on an AVIP for nine patients with locally advanced non-small-cell lung cancer were recalculated on each phase. Dose-volume histogram (DVH) metrics extracted and tumour control probabilities (TCP) were calculated. These were evaluated by Bland–Altman analysis and Pearson Correlation.Results:The largest difference between clinical target volume (CTV) on the individual phases and the internal CTV (iCTV) on the AVIP was seen for the smallest volume. For the planning target volume, the mean of each metric across all phases is well represented by the AVIP value. For most patients, TCPs from individual phases are representative of that on the AVIP. Organ at risk metrics from the AVIP are similar to those seen across all phases.Findings:Utilising traditional DVH metrics on an AVIP is generally valid, however, additional investigation may be required for small target volumes in combination with large motion as the differences between the values on the AVIP and any given phase may be significant.
Collapse
|
3
|
Schrenk O, Spindeldreier CK, Schmitt D, Roeder F, Bangert M, Burigo LN, Pfaffenberger A. The effect of density overrides on magnetic resonance-guided radiation therapy planning for lung cancer. PHYSICS & IMAGING IN RADIATION ONCOLOGY 2018; 8:23-27. [PMID: 33458412 PMCID: PMC7807559 DOI: 10.1016/j.phro.2018.11.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2018] [Revised: 11/08/2018] [Accepted: 11/09/2018] [Indexed: 12/31/2022]
Abstract
Background and Purpose Inverse treatment planning for lung cancer can be challenging since density heterogeneities may appear inside the planning target volume (PTV). One method to improve the quality of intensity modulation is the override of low density tissues inside the PTV during plan optimization. For magnetic resonance-guided radiation therapy (MRgRT), where the influence of the magnetic field on secondary electrons is sensitive to the tissue density, the reliability of density overrides has not yet been proven. This work, therefore, gains a first insight into density override strategies for MRgRT. Material and methods Monte Carlo-based treatment plans for five lung cancer patients were generated based on free-breathing CTs and two density override strategies. Different magnetic field configurations were considered with their effect being accounted for during optimization. Optimized plans were forward calculated to 4D-CTs and accumulated for the comparison of planned and expected delivered dose. Results For MRgRT, density overrides led to a discrepancy between the delivered and planned dose. The tumor volume coverage deteriorated for perpendicular magnetic fields of 1.5 T to 93.6% (D98%). For inline fields a maximal increase of 2.2% was found for the mean dose. In terms of organs at risk, a maximal sparing of 0.6 Gy and 0.9 Gy was observed for lung and heart, respectively. Conclusions In this work, first results on the effect of density overrides on treatment planning for MRgRT are presented. It was observed that the underestimation of magnetic field effects in overridden densities during treatment planning resulted in an altered delivered dose, depending on the field strength and orientation.
Collapse
Affiliation(s)
- Oliver Schrenk
- Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- Medical Faculty, University of Heidelberg, Heidelberg, Germany
| | - Claudia Katharina Spindeldreier
- Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Daniela Schmitt
- Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Falk Roeder
- Clinical Cooperation Unit Molecular Radiooncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Department of Radiation Oncology, University of Munich (LMU), Munich, Germany
| | - Mark Bangert
- Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
| | - Lucas Norberto Burigo
- Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
| | - Asja Pfaffenberger
- Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
| |
Collapse
|
4
|
Aboudaram A, Khalifa J, Massabeau C, Simon L, Hadj Henni A, Thureau S. [Image-guided radiotherapy in lung cancer]. Cancer Radiother 2018; 22:602-607. [PMID: 30104150 DOI: 10.1016/j.canrad.2018.06.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2018] [Accepted: 06/29/2018] [Indexed: 12/20/2022]
Abstract
Image-guided radiotherapy takes place at every step of the treatment in lung cancer, from treatment planning, with fusion imaging, to daily in-room repositioning. Managing tumoral and surrounding thoracic structures motion has been allowed since the routine use of 4D computed tomography (4DCT). The integration of respiratory motion has been made with "passive" techniques based on reconstruction images from 4DCT planning, or "active" techniques adapted to the patient's breathing. Daily repositioning is based on regular images, weekly or daily, low (kV) or high (MV) energy. MRI and functional imaging also play an important part in lung cancer radiation and open the way for adaptative radiotherapy.
Collapse
Affiliation(s)
- A Aboudaram
- Département de radiothérapie, institut universitaire du cancer de Toulouse-oncopôle, 1, avenue Irène-Joliot Curie, 31037 Toulouse, France.
| | - J Khalifa
- Département de radiothérapie, institut universitaire du cancer de Toulouse-oncopôle, 1, avenue Irène-Joliot Curie, 31037 Toulouse, France
| | - C Massabeau
- Département de radiothérapie, institut universitaire du cancer de Toulouse-oncopôle, 1, avenue Irène-Joliot Curie, 31037 Toulouse, France
| | - L Simon
- Département de radiothérapie, institut universitaire du cancer de Toulouse-oncopôle, 1, avenue Irène-Joliot Curie, 31037 Toulouse, France; CRCT UMR 1037 Inserm/UPS, 2, avenue Hubert-Curien, 31037 Toulouse, France
| | - A Hadj Henni
- Département de physique médicale, centre Henri-Becquerel, 1, rue d'Amiens, 76000 Rouen, France
| | - S Thureau
- Département de radiothérapie, centre Henri-Becquerel, 1, rue d'Amiens, 76000 Rouen, France; Laboratoire QuantIF, EA4108-Litis, FR CNRS 3638, 1, rue d'Amiens, 76000 Rouen, France; Département de médecine nucléaire, centre Henri-Becquerel, 1, rue d'Amiens, 76000 Rouen, France
| |
Collapse
|
5
|
Mogadas N, Sothmann T, Knopp T, Gauer T, Petersen C, Werner R. Influence of deformable image registration on 4D dose simulation for extracranial SBRT: A multi-registration framework study. Radiother Oncol 2018; 127:225-232. [PMID: 29606523 DOI: 10.1016/j.radonc.2018.03.015] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Revised: 03/14/2018] [Accepted: 03/14/2018] [Indexed: 12/25/2022]
Abstract
BACKGROUND AND PURPOSE To evaluate the influence of deformable image registration approaches on correspondence model-based 4D dose simulation in extracranial SBRT by means of open source deformable image registration (DIR) frameworks. MATERIAL AND METHODS Established DIR algorithms of six different open source DIR frameworks were considered and registration accuracy evaluated using freely available 4D image data. Furthermore, correspondence models (regression-based correlation of external breathing signal measurements and internal structure motion field) were built and model accuracy evaluated. Finally, the DIR algorithms were applied for motion field estimation in radiotherapy planning 4D CT data of five lung and five liver lesion patients, correspondence model formation, and model-based 4D dose simulation. Deviations between the original, statically planned and the 4D-simulated VMAT dose distributions were analyzed and correlated to DIR accuracy differences. RESULTS Registration errors varied among the DIR approaches, with lower DIR accuracy translating into lower correspondence modeling accuracy. Yet, for lung metastases, indices of 4D-simulated dose distributions widely agreed, irrespective of DIR accuracy differences. In contrast, liver metastases 4D dose simulation results strongly vary for the different DIR approaches. CONCLUSIONS Especially in treatment areas with low image contrast (e.g. the liver), DIR-based 4D dose simulation results strongly depend on the applied DIR algorithm, drawing resulting dose simulations and indices questionable.
Collapse
Affiliation(s)
- Nik Mogadas
- Department of Computational Neuroscience, University Medical Center Hamburg-Eppendorf, Germany
| | - Thilo Sothmann
- Department of Computational Neuroscience, University Medical Center Hamburg-Eppendorf, Germany; Department of Radiotherapy and Radio-Oncology, University Medical Center Hamburg-Eppendorf, Germany.
| | - Tobias Knopp
- Section for Biomedical Imaging, University Medical Center Hamburg-Eppendorf, Germany
| | - Tobias Gauer
- Department of Radiotherapy and Radio-Oncology, University Medical Center Hamburg-Eppendorf, Germany
| | - Cordula Petersen
- Department of Radiotherapy and Radio-Oncology, University Medical Center Hamburg-Eppendorf, Germany
| | - René Werner
- Department of Computational Neuroscience, University Medical Center Hamburg-Eppendorf, Germany
| |
Collapse
|
6
|
Yaparpalvi R, Garg MK, Shen J, Bodner WR, Mynampati DK, Gafar A, Kuo HC, Basavatia AK, Ohri N, Hong LX, Kalnicki S, Tome WA. Evaluating which plan quality metrics are appropriate for use in lung SBRT. Br J Radiol 2018; 91:20170393. [PMID: 29227151 PMCID: PMC5965485 DOI: 10.1259/bjr.20170393] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2017] [Revised: 11/14/2017] [Accepted: 12/05/2017] [Indexed: 12/31/2022] Open
Abstract
OBJECTIVE Several dose metrics in the categories-homogeneity, coverage, conformity and gradient have been proposed in literature for evaluating treatment plan quality. In this study, we applied these metrics to characterize and identify the plan quality metrics that would merit plan quality assessment in lung stereotactic body radiation therapy (SBRT) dose distributions. METHODS Treatment plans of 90 lung SBRT patients, comprising 91 targets, treated in our institution were retrospectively reviewed. Dose calculations were performed using anisotropic analytical algorithm (AAA) with heterogeneity correction. A literature review on published plan quality metrics in the categories-coverage, homogeneity, conformity and gradient was performed. For each patient, using dose-volume histogram data, plan quality metric values were quantified and analysed. RESULTS For the study, the radiation therapy oncology group (RTOG) defined plan quality metrics were: coverage (0.90 ± 0.08); homogeneity (1.27 ± 0.07); conformity (1.03 ± 0.07) and gradient (4.40 ± 0.80). Geometric conformity strongly correlated with conformity index (p < 0.0001). Gradient measures strongly correlated with target volume (p < 0.0001). The RTOG lung SBRT protocol advocated conformity guidelines for prescribed dose in all categories were met in ≥94% of cases. The proportion of total lung volume receiving doses of 20 Gy and 5 Gy (V20 and V5) were mean 4.8% (±3.2) and 16.4% (±9.2), respectively. CONCLUSION Based on our study analyses, we recommend the following metrics as appropriate surrogates for establishing SBRT lung plan quality guidelines-coverage % (ICRU 62), conformity (CN or CIPaddick) and gradient (R50%). Furthermore, we strongly recommend that RTOG lung SBRT protocols adopt either CN or CIPadddick in place of prescription isodose to target volume ratio for conformity index evaluation. Advances in knowledge: Our study metrics are valuable tools for establishing lung SBRT plan quality guidelines.
Collapse
Affiliation(s)
- Ravindra Yaparpalvi
- Department of Radiation Oncology, Montefiore Medical Center and the Albert Einstein College of Medicine, Bronx, NY, USA
| | - Madhur K Garg
- Department of Radiation Oncology, Montefiore Medical Center and the Albert Einstein College of Medicine, Bronx, NY, USA
| | - Jin Shen
- Department of Radiation Oncology, Montefiore Medical Center and the Albert Einstein College of Medicine, Bronx, NY, USA
| | - William R Bodner
- Department of Radiation Oncology, Montefiore Medical Center and the Albert Einstein College of Medicine, Bronx, NY, USA
| | - Dinesh K Mynampati
- Department of Radiation Oncology, Montefiore Medical Center and the Albert Einstein College of Medicine, Bronx, NY, USA
| | - Aleiya Gafar
- Department of Radiation Oncology, Montefiore Medical Center and the Albert Einstein College of Medicine, Bronx, NY, USA
| | - Hsiang-Chi Kuo
- Department of Radiation Oncology, Montefiore Medical Center and the Albert Einstein College of Medicine, Bronx, NY, USA
| | - Amar K Basavatia
- Department of Radiation Oncology, Montefiore Medical Center and the Albert Einstein College of Medicine, Bronx, NY, USA
| | - Nitin Ohri
- Department of Radiation Oncology, Montefiore Medical Center and the Albert Einstein College of Medicine, Bronx, NY, USA
| | - Linda X Hong
- Department of Radiation Oncology, Montefiore Medical Center and the Albert Einstein College of Medicine, Bronx, NY, USA
| | - Shalom Kalnicki
- Department of Radiation Oncology, Montefiore Medical Center and the Albert Einstein College of Medicine, Bronx, NY, USA
| | - Wolfgang A Tome
- Department of Radiation Oncology, Montefiore Medical Center and the Albert Einstein College of Medicine, Bronx, NY, USA
| |
Collapse
|
7
|
Brandner ED, Chetty IJ, Giaddui TG, Xiao Y, Huq MS. Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology. Med Phys 2017; 44:2595-2612. [PMID: 28317123 DOI: 10.1002/mp.12227] [Citation(s) in RCA: 99] [Impact Index Per Article: 14.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Revised: 01/23/2017] [Accepted: 03/10/2017] [Indexed: 12/11/2022] Open
Abstract
The efficacy of stereotactic body radiotherapy (SBRT) has been well demonstrated. However, it presents unique challenges for accurate planning and delivery especially in the lungs and upper abdomen where respiratory motion can be significantly confounding accurate targeting and avoidance of normal tissues. In this paper, we review the current literature on SBRT for lung and upper abdominal tumors with particular emphasis on addressing respiratory motion and its affects. We provide recommendations on strategies to manage motion for different, patient-specific situations. Some of the recommendations will potentially be adopted to guide clinical trial protocols.
Collapse
Affiliation(s)
- Edward D Brandner
- Department of Radiation Oncology, University of Pittsburgh Cancer Institute and UPMC CancerCenter, Pittsburgh, PA, 15232, USA
| | - Indrin J Chetty
- Department of Radiation Oncology, Henry Ford Health System, Detroit, MI, 48202, USA
| | - Tawfik G Giaddui
- Sidney Kimmel Cancer Center, Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, 19107, USA
| | - Ying Xiao
- Imaging and Radiation Oncology Core (IROC), University of Pennsylvania, Philadelphia, PA, 19104, USA
| | - M Saiful Huq
- Department of Radiation Oncology, University of Pittsburgh Cancer Institute and UPMC CancerCenter, Pittsburgh, PA, 15232, USA
| |
Collapse
|
8
|
Ohira S, Ueda Y, Hashimoto M, Miyazaki M, Isono M, Kamikaseda H, Masaoka A, Takashina M, Koizumi M, Teshima T. VMAT-SBRT planning based on an average intensity projection for lung tumors located in close proximity to the diaphragm: a phantom and clinical validity study. JOURNAL OF RADIATION RESEARCH 2016; 57:91-97. [PMID: 26419645 PMCID: PMC4708914 DOI: 10.1093/jrr/rrv058] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/23/2015] [Revised: 08/05/2015] [Accepted: 08/21/2015] [Indexed: 06/05/2023]
Abstract
The aim of the this study was to validate the use of an average intensity projection (AIP) for volumetric-modulated arc therapy for stereotactic body radiation therapy (VMAT-SBRT) planning for a moving lung tumor located near the diaphragm. VMAT-SBRT plans were created using AIPs reconstructed from 10 phases of 4DCT images that were acquired with a target phantom moving with amplitudes of 5, 10, 20 and 30 mm. To generate a 4D dose distribution, the static dose for each phase was recalculated and the doses were accumulated by using the phantom position known for each phase. For 10 patients with lung tumors, a deformable registration was used to generate 4D dose distributions. Doses to the target volume obtained from the AIP plan and the 4D plan were compared, as were the doses obtained from each plan to the organs at risk (OARs). In both phantom and clinical study, dose discrepancies for all parameters of the dose volume (D(min), D(99), D(max), D(1) and D(mean)) to the target were <3%. The discrepancies of D(max) for spinal cord, esophagus and heart were <1 Gy, and the discrepancy of V20 for lung tissue was <1%. However, for OARs with large respiratory motion, the discrepancy of the D(max) was as much as 9.6 Gy for liver and 5.7 Gy for stomach. Thus, AIP is clinically acceptable as a planning CT image for predicting 4D dose, but doses to the OARs with large respiratory motion were underestimated with the AIP approach.
Collapse
Affiliation(s)
- Shingo Ohira
- Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Nakamichi 1-3-3, Higashinari-ku, Osaka, 537-8511, Japan Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Yoshihiro Ueda
- Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Nakamichi 1-3-3, Higashinari-ku, Osaka, 537-8511, Japan Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita, Japan
| | - Misaki Hashimoto
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Nakamichi 1-3-3, Higashinari-ku, Osaka, 537-8511, Japan
| | - Masaru Isono
- Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Nakamichi 1-3-3, Higashinari-ku, Osaka, 537-8511, Japan
| | - Hiroshi Kamikaseda
- Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Nakamichi 1-3-3, Higashinari-ku, Osaka, 537-8511, Japan
| | - Akira Masaoka
- Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Nakamichi 1-3-3, Higashinari-ku, Osaka, 537-8511, Japan
| | - Masaaki Takashina
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Masahiko Koizumi
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Teruki Teshima
- Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Nakamichi 1-3-3, Higashinari-ku, Osaka, 537-8511, Japan
| |
Collapse
|
9
|
Martin S, Brophy M, Palma D, Louie AV, Yu E, Yaremko B, Ahmad B, Barron JL, Beauchemin SS, Rodrigues G, Gaede S. A proposed framework for consensus-based lung tumour volume auto-segmentation in 4D computed tomography imaging. Phys Med Biol 2015; 60:1497-518. [DOI: 10.1088/0031-9155/60/4/1497] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
10
|
Malone C, Rock L, Skourou C. Efficacy evaluation of retrospectively applying the Varian normal breathing predictive filter for volume definition and artifact reduction in 4D CT lung patients. J Appl Clin Med Phys 2014; 15:4315. [PMID: 24892327 PMCID: PMC5711067 DOI: 10.1120/jacmp.v15i3.4315] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2012] [Revised: 01/02/2014] [Accepted: 12/27/2013] [Indexed: 12/25/2022] Open
Abstract
Phase-based sorting of four-dimensional computed tomography (4D CT) datasets is prone to image artifacts due to patient's breathing irregularities that occur during the image acquisition. The purpose of this study is to investigate the effect of the Varian normal breathing predictive filter (NBPF) as a retrospective phase-sorting parameter in 4D CT. Ten 4D CT lung cancer datasets were obtained. The volumes of all tumors present, as well as the total lung volume, were calculated on the maximum intensity projection (MIP) images as well as each individual phase image. The NBPF was varied retrospectively within the available range, and changes in volume and image quality were recorded. The patients' breathing trace was analysed and the magnitude and location of any breathing irregularities were correlated to the behavior of the NBPF. The NBPF was found to have a considerable effect on the quality of the images in MIP and single-phase datasets. When used appropriately, the NBPF is shown to have the ability to account for and correct image artifacts. However, when turned off (0%) or set above a critical level (approximately 40%), it resulted in erroneous volume reconstructions with variations in tumor volume up to 26.6%. Those phases associated with peak inspiration were found to be more susceptible to changes in the NBPF. The NBPF settings selected prior to exporting the breathing trace for patients evaluated using 4D CT directly affect the accuracy of the targeting and volume estimation of lung tumors. Recommendations are made to address potential errors in patient anatomy introduced by breathing irregularities, specifically deep breath or cough irregularities, by implementing the proper settings and use of this tool.
Collapse
|
11
|
Chan MKH, Kwong DLW, Ng SCY, Tong ASM, Tam EKW. Experimental evaluations of the accuracy of 3D and 4D planning in robotic tracking stereotactic body radiotherapy for lung cancers. Med Phys 2013; 40:041712. [PMID: 23556882 DOI: 10.1118/1.4794505] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
PURPOSE Due to the complexity of 4D target tracking radiotherapy, the accuracy of this treatment strategy should be experimentally validated against established standard 3D technique. This work compared the accuracy of 3D and 4D dose calculations in respiration tracking stereotactic body radiotherapy (SBRT). METHODS Using the 4D planning module of the CyberKnife treatment planning system, treatment plans for a moving target and a static off-target cord structure were created on different four-dimensional computed tomography (4D-CT) datasets of a thorax phantom moving in different ranges. The 4D planning system used B-splines deformable image registrations (DIR) to accumulate dose distributions calculated on different breathing geometries, each corresponding to a static 3D-CT image of the 4D-CT dataset, onto a reference image to compose a 4D dose distribution. For each motion, 4D optimization was performed to generate a 4D treatment plan of the moving target. For comparison with standard 3D planning, each 4D plan was copied to the reference end-exhale images and a standard 3D dose calculation was followed. Treatment plans of the off-target structure were first obtained by standard 3D optimization on the end-exhale images. Subsequently, they were applied to recalculate the 4D dose distributions using DIRs. All dose distributions that were initially obtained using the ray-tracing algorithm with equivalent path-length heterogeneity correction (3D EPL and 4D EPL) were recalculated by a Monte Carlo algorithm (3D MC and 4D MC) to further investigate the effects of dose calculation algorithms. The calculated 3D EPL, 3D MC, 4D EPL, and 4D MC dose distributions were compared to measurements by Gafchromic EBT2 films in the axial and coronal planes of the moving target object, and the coronal plane for the static off-target object based on the γ metric at 5%/3mm criteria (γ5%/3mm). Treatment plans were considered acceptable if the percentage of pixels passing γ5%/3mm (Pγ<1) ≥ 90%. RESULTS The averaged Pγ<1 values of the 3D EPL, 3D MC, 4D EPL, and 4D MC dose calculation methods for the moving target plans are 95%, 95%, 94%, and 95% for reproducible motion, and 95%, 96%, 94%, and 93% for nonreproducible motion during actual treatment delivery. The overall measured target dose distributions are in better agreement with the 3DMC dose distributions than the 4DMC dose distributions. Conversely, measured dose distributions agree much better with the 4D EPL/MC than the 3D EPL/MC dose distributions in the static off-target structure, resulting in higher Pγ<1 values with 4D EPL/MC (91%) vs 3D EPL (24%) and 3D MC (25%). Systematic changes of target motion reduced the averaged Pγ<1 to 47% and 53% for 4D EPL and 4D MC dose calculations, and 22% for 3D EPL/MC dose calculations in the off-target films. CONCLUSIONS In robotic tracking SBRT, 4D treatment planning was found to yield better prediction of the dose distributions in the off-target structure, but not necessarily in the moving target, compared to standard 3D treatment planning, for reproducible and nonreproducible target motion. It is important to ensure on a patient-by-patient basis that the cumulative uncertainty associated with the 4D-CT artifacts, deformable image registration, and motion variability is significantly smaller than the cumulative uncertainty occurred in standard 3D planning in order to make 4D planning a justified option.
Collapse
Affiliation(s)
- Mark K H Chan
- Department of Clinical Oncology, The University of Hong Kong, Tuen Mun Hospital, Hong Kong Special Administrative Region.
| | | | | | | | | |
Collapse
|
12
|
Kim SK, Kang MK, Yea JW, Oh SA. Dosimetric evaluation of a moving tumor target in intensity-modulated radiation therapy (IMRT) for lung cancer patients. JOURNAL OF THE KOREAN PHYSICAL SOCIETY 2013; 63:67-70. [DOI: 10.3938/jkps.63.67] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/03/2023]
|
13
|
Jensen MD, Abdellatif A, Chen J, Wong E. Study of the IMRT interplay effect using a 4DCT Monte Carlo dose calculation. Phys Med Biol 2012; 57:N89-99. [DOI: 10.1088/0031-9155/57/8/n89] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
14
|
Tewatia DK, Tolakanahalli RP, Paliwal BR, Tomé WA. Time series analyses of breathing patterns of lung cancer patients using nonlinear dynamical system theory. Phys Med Biol 2011; 56:2161-81. [DOI: 10.1088/0031-9155/56/7/017] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
15
|
Worm ES, Hansen AT, Petersen JB, Muren LP, Præstegaard LH, Høyer M. Inter- and intrafractional localisation errors in cone-beam CT guided stereotactic radiation therapy of tumours in the liver and lung. Acta Oncol 2010; 49:1177-83. [PMID: 20590367 DOI: 10.3109/0284186x.2010.498435] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
BACKGROUND Localisation errors in cone-beam CT (CBCT) guided stereotactic body radiation therapy (SBRT) were evaluated and compared to positioning using the external coordinates of a stereotactic body frame (SBF) alone. Possible correlations to patient- or treatment-specific factors such as body mass index (BMI), planning time, treatment delivery time, and distance between tumour and spinal cord were explored to determine whether they influenced on the benefit of image-guidance. MATERIAL AND METHODS A total of 34 patients received SBRT (3 fractions) for tumours in the liver (15 patients) or the lung (19 patients). Immobilisation and positioning was obtained with a SBF. Pre- and post-treatment CBCT scans were registered with the bony anatomy of the planning CT to find inter- and intrafractional patient positioning errors (PPE). For lung tumour patients, matching was also performed on the tumours to find the tumour positioning errors (TPE) and baseline shifts relative to bony anatomy. RESULTS The mean inter- and intrafractional 3D vector PPE was 4.5 ± 2.7 mm (average ± SD) and 1.5 ± 0.6 mm, respectively, for the combined group of patients. For lung tumours, the interfractional misalignment was 5.6 ± 1.8 mm. The baseline shift was 3.9 ± 2.0 mm. Intrafractional TPE and baseline shifts were 2.1 ± 0.7 mm and 1.9 ± 0.6 mm, respectively. The magnitude of interfractional baseline shift was closely correlated with the distance between the tumour and the spinal cord. Intrafractional errors were independent of patient BMI, age or gender. CONCLUSION Image-guidance reduced setup errors considerably. The study demonstrated the benefit of CBCT-guidance regardless of patient specific factors such as BMI, age or gender. Protection of the spinal cord was facilitated by the correlation between the tumour position relative to the spinal cord and the magnitude of baseline shift.
Collapse
Affiliation(s)
- Esben S Worm
- Department of Medical Physics, Aarhus University Hospital, Aarhus, Denmark.
| | | | | | | | | | | |
Collapse
|
16
|
Han K, Basran PS, Cheung P. Comparison of helical and average computed tomography for stereotactic body radiation treatment planning and normal tissue contouring in lung cancer. Clin Oncol (R Coll Radiol) 2010; 22:862-7. [PMID: 20863675 DOI: 10.1016/j.clon.2010.08.010] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2010] [Revised: 05/04/2010] [Accepted: 06/28/2010] [Indexed: 01/09/2023]
Abstract
AIMS To compare average computed tomography (CT(AVE)) datasets with free breathing helical computed tomography (CT(HEL)) for contouring organs at risk (OARs) and radiation treatment planning in patients receiving stereotactic body radiation therapy (SBRT) in the lung. MATERIALS AND METHODS Ten SBRT patients with peripheral stage I non-small cell lung cancer underwent a CT(HEL) and a four-dimensional computed tomography scan in the treatment position. CT(AVE) datasets were generated from the four-dimensional computed tomography scan. The following OARs were delineated on the CT(HEL) and CT(AVE) datasets of each patient: lung minus internal target volume, trachea/main bronchus, heart, oesophagus and spinal cord. Volumes and geometric centres of the OARs, as well as the dosimetric impact of planning with these different datasets, were examined. RESULTS There were no statistical differences in the OAR geometric centre coordinates nor in the OAR volumes between the CT(HEL) and CT(AVE) datasets, except that CT(AVE)-defined trachea/main bronchus and lung minus internal target volume mean volumes were larger than those defined on the CT(HEL) (46, 43 cm³ and 3516, 3378 cm³, respectively, P<0.05). Despite this, there were no significant differences in the mean and maximum doses to the OAR contours when using the CT(HEL) or CT(AVE) for planning (<4% average change in the maximum and mean doses for all OARs, P>0.05). There were also no significant differences in the locations of the hotspots within OARs among the CT(HEL) or CT(AVE) datasets (P>0.05). CONCLUSIONS CT(AVE) datasets may be used in place of CT(HEL) for OAR contouring and dose calculations. When four-dimensional computed tomography is available, it may not be necessary to acquire a separate CT(HEL) scan for OAR contouring or dosimetric purposes.
Collapse
Affiliation(s)
- K Han
- Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Canada
| | | | | |
Collapse
|
17
|
Velec M, Moseley JL, Eccles CL, Craig T, Sharpe MB, Dawson LA, Brock KK. Effect of breathing motion on radiotherapy dose accumulation in the abdomen using deformable registration. Int J Radiat Oncol Biol Phys 2010; 80:265-72. [PMID: 20732755 DOI: 10.1016/j.ijrobp.2010.05.023] [Citation(s) in RCA: 84] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2010] [Revised: 05/26/2010] [Accepted: 05/29/2010] [Indexed: 12/14/2022]
Abstract
PURPOSE To investigate the effect of breathing motion and dose accumulation on the planned radiotherapy dose to liver tumors and normal tissues using deformable image registration. METHODS AND MATERIALS Twenty-one free-breathing stereotactic liver cancer radiotherapy patients, planned on static exhale computed tomography (CT) for 27-60 Gy in six fractions, were included. A biomechanical model-based deformable image registration algorithm retrospectively deformed each exhale CT to inhale CT. This deformation map was combined with exhale and inhale dose grids from the treatment planning system to accumulate dose over the breathing cycle. Accumulation was also investigated using a simple rigid liver-to-liver registration. Changes to tumor and normal tissue dose were quantified. RESULTS Relative to static plans, mean dose change (range) after deformable dose accumulation (as % of prescription dose) was -1 (-14 to 8) to minimum tumor, -4 (-15 to 0) to maximum bowel, -4 (-25 to 1) to maximum duodenum, 2 (-1 to 9) to maximum esophagus, -2 (-13 to 4) to maximum stomach, 0 (-3 to 4) to mean liver, and -1 (-5 to 1) and -2 (-7 to 1) to mean left and right kidneys. Compared to deformable registration, rigid modeling had changes up to 8% to minimum tumor and 7% to maximum normal tissues. CONCLUSION Deformable registration and dose accumulation revealed potentially significant dose changes to either a tumor or normal tissue in the majority of cases as a result of breathing motion. These changes may not be accurately accounted for with rigid motion.
Collapse
Affiliation(s)
- Michael Velec
- Radiation Medicine Program, Princess Margaret Hospital, University Health Network, Toronto, Canada.
| | | | | | | | | | | | | |
Collapse
|
18
|
Bettinardi V, Picchio M, Di Muzio N, Gianolli L, Gilardi MC, Messa C. Detection and compensation of organ/lesion motion using 4D-PET/CT respiratory gated acquisition techniques. Radiother Oncol 2010; 96:311-6. [PMID: 20708809 DOI: 10.1016/j.radonc.2010.07.014] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2010] [Revised: 07/14/2010] [Accepted: 07/15/2010] [Indexed: 12/25/2022]
Abstract
PURPOSE To describe the degradation effects produced by respiratory organ and lesion motion on PET/CT images and to define the role of respiratory gated (RG) 4D-PET/CT techniques to compensate for such effects. METHODS Based on the literature and on our own experience, technical recommendations and clinical indications for the use of RG 4D PET/CT have been outlined. RESULTS RG 4D-PET/CT techniques require a state of the art PET/CT scanner, a respiratory monitoring system and dedicated acquisition and processing protocols. Patient training is particularly important to obtain a regular breathing pattern. An adequate number of phases has to be selected to balance motion compensation and statistical noise. RG 4D PET/CT motion free images may be clinically useful for tumour tissue characterization, monitoring patient treatment and target definition in radiation therapy planning. CONCLUSIONS RG 4D PET/CT is a valuable tool to improve image quality and quantitative accuracy and to assess and measure organ and lesion motion for radiotherapy planning.
Collapse
|
19
|
Thwaites DI, Verellen D. Vorsprung durch Technik: evolution, implementation, QA and safety of new technology in radiotherapy. Radiother Oncol 2010; 94:125-8. [PMID: 20170973 DOI: 10.1016/j.radonc.2010.02.004] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2010] [Accepted: 02/09/2010] [Indexed: 11/18/2022]
|
20
|
Hof H, Rhein B, Haering P, Kopp-Schneider A, Debus J, Herfarth K. 4D-CT-based target volume definition in stereotactic radiotherapy of lung tumours: Comparison with a conventional technique using individual margins. Radiother Oncol 2009; 93:419-23. [PMID: 19782418 DOI: 10.1016/j.radonc.2009.08.040] [Citation(s) in RCA: 79] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2009] [Revised: 08/24/2009] [Accepted: 08/25/2009] [Indexed: 11/17/2022]
Affiliation(s)
- Holger Hof
- Department of Radiation Oncology, University of Heidelberg, Heidelberg, Germany.
| | | | | | | | | | | |
Collapse
|
21
|
Bender ET, Tomé WA. The utilization of consistency metrics for error analysis in deformable image registration. Phys Med Biol 2009; 54:5561-77. [PMID: 19717890 DOI: 10.1088/0031-9155/54/18/014] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The aim of this study was to investigate the utility of consistency metrics, such as inverse consistency, in contour-based deformable registration error analysis. Four images were acquired of the same phantom that has experienced varying levels of deformation. The deformations were simulated with deformable image registration. Using calculated deformation maps, the inconsistencies within the algorithm were investigated. This can be done, for example, by calculating deformation maps both in forward and reverse directions and applying them subsequently to an image. If the algorithm is not inverse consistent, then this final image will not be the same as the original, as it should be. Other consistency tests were done, for example by comparing different algorithms or by applying the deformation maps to a circular set of multiple deformations, whereby the original and final images are in fact the same. The resulting composite deformation map in this case contains a combination of the errors within those maps, because if error free, the resulting deformation map should be zero everywhere. We have termed this the generalized inverse consistency error map (Sigma(Chi)). The correlation between the consistency metrics and registration error varied considerably depending on the registration algorithm and type of consistency metric. There was also a trend for the actual registration error to be larger than the consistency metrics. A disadvantage of these techniques is that good performance in these consistency checks is a necessary but not sufficient condition for an accurate deformation method.
Collapse
Affiliation(s)
- Edward T Bender
- Department of Medical Physics, The University of Wisconsin-Madison, 1111 Highland Ave, Madison, WI 53705-2275, USA
| | | |
Collapse
|
22
|
Baumann M, Zips D, Appold S. Radiotherapy of lung cancer: Technology meets biology meets multidisciplinarity. Radiother Oncol 2009; 91:279-81. [DOI: 10.1016/j.radonc.2009.05.001] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2009] [Accepted: 05/07/2009] [Indexed: 11/26/2022]
|
23
|
Hugo GD, Campbell J, Zhang T, Yan D. Cumulative lung dose for several motion management strategies as a function of pretreatment patient parameters. Int J Radiat Oncol Biol Phys 2009; 74:593-601. [PMID: 19327911 DOI: 10.1016/j.ijrobp.2008.12.069] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2008] [Revised: 11/03/2008] [Accepted: 12/24/2008] [Indexed: 12/25/2022]
Abstract
PURPOSE To evaluate patient parameters that may predict for relative differences in cumulative four-dimensional (4D) lung dose among several motion management strategies. METHODS AND MATERIALS Deformable image registration and dose accumulation were used to generate 4D treatment plans for 18 patients with 4D computed tomography scans. Three plans were generated to simulate breath hold at normal inspiration, target tracking with the beam aperture, and mid-ventilation aperture (control of the target at the mean daily position and application of an iteratively computed margin to compensate for respiration). The relative reduction in mean lung dose (MLD) between breath hold and mid-ventilation aperture (DeltaMLD(BH)) and between target tracking and mid-ventilation aperture (DeltaMLD(TT)) was calculated. Associations between these two variables and parameters of the lesion (excursion, size, location, and deformation) and dose distribution (local dose gradient near the target) were also calculated. RESULTS The largest absolute and percentage differences in MLD were 1.0 Gy and 21.5% between breath hold and mid-ventilation aperture. DeltaMLD(BH) was significantly associated (p < 0.05) with tumor excursion. The DeltaMLD(TT) was significantly associated with excursion, deformation, and local dose gradient. A linear model was constructed to represent DeltaMLD vs. excursion. For each 5 mm of excursion, target tracking reduced the MLD by 4% compared with the results of a mid-ventilation aperture plan. For breath hold, the reduction was 5% per 5 mm of excursion. CONCLUSIONS The relative difference in MLD among different motion management strategies varied with patient and tumor characteristics for a given dosimetric target coverage. Tumor excursion is useful to aid in stratifying patients according to appropriate motion management strategies.
Collapse
Affiliation(s)
- Geoffrey D Hugo
- Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI, USA.
| | | | | | | |
Collapse
|