1
|
Feng Z, Sun E, China D, Huang X, Hooshangnejad H, Gonzalez EA, Bell MAL, Ding K. Enhancing Image-Guided Radiation Therapy for Pancreatic Cancer: Utilizing Aligned Peak Response Beamforming in Flexible Array Transducers. Cancers (Basel) 2024; 16:1244. [PMID: 38610923 PMCID: PMC11011135 DOI: 10.3390/cancers16071244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 02/28/2024] [Accepted: 03/08/2024] [Indexed: 04/14/2024] Open
Abstract
To develop ultrasound-guided radiotherapy, we proposed an assistant structure with embedded markers along with a novel alternative method, the Aligned Peak Response (APR) method, to alter the conventional delay-and-sum (DAS) beamformer for reconstructing ultrasound images obtained from a flexible array. We simulated imaging targets in Field-II using point target phantoms with point targets at different locations. In the experimental phantom ultrasound images, image RF data were acquired with a flexible transducer with in-house assistant structures embedded with needle targets for testing the accuracy of the APR method. The lateral full width at half maximum (FWHM) values of the objective point target (OPT) in ground truth ultrasound images, APR-delayed ultrasound images with a flat shape, and images acquired with curved transducer radii of 500 mm and 700 mm were 3.96 mm, 4.95 mm, 4.96 mm, and 4.95 mm. The corresponding axial FWHM values were 1.52 mm, 4.08 mm, 5.84 mm, and 5.92 mm, respectively. These results demonstrate that the proposed assistant structure and the APR method have the potential to construct accurate delay curves without external shape sensing, thereby enabling a flexible ultrasound array for tracking pancreatic tumor targets in real time for radiotherapy.
Collapse
Affiliation(s)
- Ziwei Feng
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA; (Z.F.); (E.S.); (H.H.)
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD 21218, USA; (E.A.G.); (M.A.L.B.)
| | - Edward Sun
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA; (Z.F.); (E.S.); (H.H.)
- Department of Computer Science, University of California, Los Angeles, CA 90095, USA
| | - Debarghya China
- Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA; (D.C.); (X.H.)
| | - Xinyue Huang
- Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA; (D.C.); (X.H.)
| | - Hamed Hooshangnejad
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA; (Z.F.); (E.S.); (H.H.)
- Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA; (D.C.); (X.H.)
| | - Eduardo A. Gonzalez
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD 21218, USA; (E.A.G.); (M.A.L.B.)
| | - Muyinatu A. Lediju Bell
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD 21218, USA; (E.A.G.); (M.A.L.B.)
- Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA; (D.C.); (X.H.)
- Department of Computer Science, Johns Hopkins University, Baltimore, MD 21218, USA
| | - Kai Ding
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA; (Z.F.); (E.S.); (H.H.)
| |
Collapse
|
2
|
Bryant JM, Sim AJ, Feygelman V, Latifi K, Rosenberg SA. Adaptive hypofractionted and stereotactic body radiotherapy for lung tumors with real-time MRI guidance. Front Oncol 2023; 13:1061854. [PMID: 36776319 PMCID: PMC9911810 DOI: 10.3389/fonc.2023.1061854] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 01/03/2023] [Indexed: 01/28/2023] Open
Abstract
The treatment of central and ultracentral lung tumors with radiotherapy remains an ongoing clinical challenge. The risk of Grade 5 toxicity with ablative radiotherapy doses to these high-risk regions is significant as shown in recent prospective studies. Magnetic resonance (MR) image-guided adaptive radiotherapy (MRgART) is a new technology and may allow the delivery of ablative radiotherapy to these high-risk regions safely. MRgART is able to achieve this by utilizing small treatment margins, real-time gating/tracking and on-table plan adaptation to maintain dose to the tumor but limit dose to critical structures. The process of MRgART is complex and has nuances and challenges for the treatment of lung tumors. We outline the critical steps needed for appropriate delivery of MRgART for lung tumors safely and effectively.
Collapse
Affiliation(s)
- John M. Bryant
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, United States
| | - Austin J. Sim
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, United States,Department of Radiation Oncology, Comprehensive Cancer Center – The James Cancer Hospital, Columbus, OH, United States
| | - Vladimir Feygelman
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, United States
| | - Kujtim Latifi
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, United States
| | - Stephen A. Rosenberg
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, United States,*Correspondence: Stephen A. Rosenberg,
| |
Collapse
|
3
|
CArdiac and REspiratory adaptive Computed Tomography (CARE-CT): a proof-of-concept digital phantom study. Phys Eng Sci Med 2022; 45:1257-1271. [PMID: 36434201 DOI: 10.1007/s13246-022-01193-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Accepted: 10/20/2022] [Indexed: 11/27/2022]
Abstract
Current respiratory 4DCT imaging for high-dose rate thoracic radiotherapy treatments are negatively affected by the complex interaction of cardiac and respiratory motion. We propose an imaging method to reduce artifacts caused by thoracic motion, CArdiac and REspiratory adaptive CT (CARE-CT), that monitors respiratory motion and ECG signals in real-time, triggering CT acquisition during combined cardiac and respiratory bins. Using a digital phantom, conventional 4DCT and CARE-CT acquisitions for nineteen patient-measured physiological traces were simulated. Ten respiratory bins were acquired for conventional 4DCT scans and ten respiratory bins during cardiac diastole were acquired for CARE-CT scans. Image artifacts were quantified for 10 common thoracic organs at risk (OAR) substructures using the differential normalized cross correlation between axial slices (ΔNCC), mean squared error (MSE) and sensitivity. For all images, on average, CARE-CT improved the ΔNCC for 18/19 and the MSE and sensitivity for all patient traces. The ΔNCC was reduced for all cardiac OARs (mean reduction 21%). The MSE was reduced for all OARs (mean reduction 36%). In the digital phantom study, the average scan time was increased from 1.8 ± 0.4 min to 7.5 ± 2.2 min with a reduction in average beam on time from 98 ± 28 s to 45 s using CARE-CT compared to conventional 4DCT. The proof-of-concept study indicates the potential for CARE-CT to image the thorax in real-time during the cardiac and respiratory cycle simultaneously, to reduce image artifacts for common thoracic OARs.
Collapse
|
4
|
Prado A, Zucca D, De la Casa MÁ, Martí J, Alonso L, de Acilu PG, García J, Hernando O, Fernández-Letón P, Rubio C. Intrafraction target shift comparison using two breath-hold systems in lung stereotactic body radiotherapy. Phys Imaging Radiat Oncol 2022; 22:57-62. [PMID: 35514526 PMCID: PMC9065403 DOI: 10.1016/j.phro.2022.04.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 04/13/2022] [Accepted: 04/20/2022] [Indexed: 12/25/2022] Open
Abstract
Background and purpose In lung Stereotactic Body Radiotherapy (SBRT) respiratory management is used to reduce target motion due to respiration. This study aimed (1) to estimate intrafraction shifts through a Cone Beam Computed Tomography (CBCT) acquired during the first treatment arc when deep inspiration breath-hold (DIBH) was performed using spirometry-based (SB) or surface-guidance (SG) systems and (2) to analyze the obtained results depending on lesion localization. Material and methods A sample of 157 patients with 243 lesions was analyzed. A total of 860 and 410 fractions were treated using SB and SG. Averaged intrafraction shifts were estimated by the offsets obtained when registering a CBCT acquired during the first treatment arc with the planning CT. Offsets were recorded in superior-inferior (SI), left-right (LR) and anterior-posterior (AP). Significance tests were applied to account for differences in average offsets and variances between DIBH systems. Systematic and random errors were computed. Results Average offset moduli were 2.4 ± 2.2 mm and 3.5 ± 2.6 mm for SB and SG treatments (p < 0.001). When comparing SB and SG offset distributions in each direction no differences were found in average values (p > 0.3). However, variances were statistically smaller for SB than for SG (p < 0.001). The number of vector moduli offsets greater than 5 mm was 2.1 times higher for SG. Compared to other locations, lower lobe lesions moduli were at least 2.3 times higher. Conclusions Both systems were accuracy-equivalent but not precision-equivalent systems. Furthermore, the SB system was more precise than the SG one. Despite DIBH, patients with lower lobe lesions had larger offsets than superior lobe ones, mainly in SI.
Collapse
Affiliation(s)
- Alejandro Prado
- Medical Physics and Radiation Protection Department, HU HM Sanchinarro, HM Hospitales, c\ Oña n°10, 28050 Madrid, Spain
| | - Daniel Zucca
- Medical Physics and Radiation Protection Department, HU HM Sanchinarro, HM Hospitales, c\ Oña n°10, 28050 Madrid, Spain
| | - Miguel Ángel De la Casa
- Medical Physics and Radiation Protection Department, HU HM Sanchinarro, HM Hospitales, c\ Oña n°10, 28050 Madrid, Spain
| | - Jaime Martí
- Medical Physics and Radiation Protection Department, HU HM Sanchinarro, HM Hospitales, c\ Oña n°10, 28050 Madrid, Spain
| | - Leyre Alonso
- Medical Physics and Radiation Protection Department, HU HM Sanchinarro, HM Hospitales, c\ Oña n°10, 28050 Madrid, Spain
| | - Paz García de Acilu
- Medical Physics and Radiation Protection Department, HU HM Puerta del Sur, HM Hospitales, Av. Carlos V n° 70, 28938 Móstoles, Madrid, Spain
| | - Juan García
- Medical Physics and Radiation Protection Department, HU HM Puerta del Sur, HM Hospitales, Av. Carlos V n° 70, 28938 Móstoles, Madrid, Spain
| | - Ovidio Hernando
- Radiation Oncology Department, HU HM Puerta del Sur, HM Hospitales, Av. Carlos V n° 70, 28938 Móstoles, Madrid, Spain
| | - Pedro Fernández-Letón
- Medical Physics and Radiation Protection Department, HU HM Sanchinarro, HM Hospitales, c\ Oña n°10, 28050 Madrid, Spain
- Medical Physics and Radiation Protection Department, HU HM Puerta del Sur, HM Hospitales, Av. Carlos V n° 70, 28938 Móstoles, Madrid, Spain
| | - Carmen Rubio
- Radiation Oncology Department, HU HM Sanchinarro, HM Hospitales, c\ Oña n°10, 28050 Madrid, Spain
- Radiation Oncology Department, HU HM Puerta del Sur, HM Hospitales, Av. Carlos V n° 70, 28938 Móstoles, Madrid, Spain
| |
Collapse
|
5
|
Knybel L, Cvek J, Neuwirth R, Jiravsky O, Hecko J, Penhaker M, Sramko M, Kautzner J. Real-time measurement of ICD lead motion during stereotactic body radiotherapy of ventricular tachycardia. ACTA ACUST UNITED AC 2021; 26:128-137. [PMID: 34046223 DOI: 10.5603/rpor.a2021.0020] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2020] [Accepted: 12/18/2020] [Indexed: 11/25/2022]
Abstract
Background Here we aimed to evaluate the respiratory and cardiac-induced motion of a ICD lead used as surrogate in the heart during stereotactic body radiotherapy (SBRT) of ventricular tachycardia (VT). Data provides insight regarding motion and motion variations during treatment. Materials and methods We analyzed the log files of surrogate motion during SBRT of ventricular tachycardia performed in 20 patients. Evaluated parameters included the ICD lead motion amplitudes; intrafraction amplitude variability; correlation error between the ICD lead and external markers; and margin expansion in the superior-inferior (SI), latero-lateral (LL), and anterior-posterior (AP) directions to cover 90% or 95% of all amplitudes. Results In the SI, LL, and AP directions, respectively, the mean motion amplitudes were 5.0 ± 2.6, 3.4. ± 1.9, and 3.1 ± 1.6 mm. The mean intrafraction amplitude variability was 2.6 ± 0.9, 1.9 ± 1.3, and 1.6 ± 0.8 mm in the SI, LL, and AP directions, respectively. The margins required to cover 95% of ICD lead motion amplitudes were 9.5, 6.7, and 5.5 mm in the SI, LL, and AP directions, respectively. The mean correlation error was 2.2 ± 0.9 mm. Conclusions Data from online tracking indicated motion irregularities and correlation errors, necessitating an increased CTV-PTV margin of 3 mm. In 35% of cases, the motion variability exceeded 3 mm in one or more directions. We recommend verifying the correlation between CTV and surrogate individually for every patient, especially for targets with posterobasal localization where we observed the highest difference between the lead and CTV motion.
Collapse
Affiliation(s)
- Lukas Knybel
- Department of Oncology, University Hospital Ostrava, Ostrava, Czech Republic
| | - Jakub Cvek
- Department of Oncology, University Hospital Ostrava, Ostrava, Czech Republic
| | | | - Otakar Jiravsky
- Department of Cardiology, Podlesi Hospital, Trinec, Czech Republic
| | - Jan Hecko
- VŠB-Technical University of Ostrava, Ostrava, Czech Republic
| | - Marek Penhaker
- VŠB-Technical University of Ostrava, Ostrava, Czech Republic
| | - Marek Sramko
- Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Josef Kautzner
- Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| |
Collapse
|
6
|
Kim D, Choi J, Lee D, Kim H, Jung J, Cho M, Lee KY. Motion correction for routine X-ray lung CT imaging. Sci Rep 2021; 11:3695. [PMID: 33580147 PMCID: PMC7880999 DOI: 10.1038/s41598-021-83403-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Accepted: 01/29/2021] [Indexed: 11/30/2022] Open
Abstract
A novel motion correction algorithm for X-ray lung CT imaging has been developed recently. It was designed to perform for routine chest or thorax CT scans without gating, namely axial or helical scans with pitch around 1.0. The algorithm makes use of two conjugate partial angle reconstruction images for motion estimation via non-rigid registration which is followed by a motion compensated reconstruction. Differently from other conventional approaches, no segmentation is adopted in motion estimation. This makes motion estimation of various fine lung structures possible. The aim of this study is to explore the performance of the proposed method in correcting the lung motion artifacts which arise even under routine CT scans with breath-hold. The artifacts are known to mimic various lung diseases, so it is of great interest to address the problem. For that purpose, a moving phantom experiment and clinical study (seven cases) were conducted. We selected the entropy and positivity as figure of merits to compare the reconstructed images before and after the motion correction. Results of both phantom and clinical studies showed a statistically significant improvement by the proposed method, namely up to 53.6% (p < 0.05) and up to 35.5% (p < 0.05) improvement by means of the positivity measure, respectively. Images of the proposed method show significantly reduced motion artifacts of various lung structures such as lung parenchyma, pulmonary vessels, and airways which are prominent in FBP images. Results of two exemplary cases also showed great potential of the proposed method in correcting motion artifacts of the aorta which is known to mimic aortic dissection. Compared to other approaches, the proposed method provides an excellent performance and a fully automatic workflow. In addition, it has a great potential to handle motions in wide range of organs such as lung structures and the aorta. We expect that this would pave a way toward innovations in chest and thorax CT imaging.
Collapse
Affiliation(s)
- Doil Kim
- CT R&D Group, Health & Medical Equipment Business, Samsung Electronics Co., Ltd., Suwon, Republic of Korea
| | - Jiyoung Choi
- CT R&D Group, Health & Medical Equipment Business, Samsung Electronics Co., Ltd., Suwon, Republic of Korea
| | - Duhgoon Lee
- CT R&D Group, Health & Medical Equipment Business, Samsung Electronics Co., Ltd., Suwon, Republic of Korea
| | - Hyesun Kim
- CT R&D Group, Health & Medical Equipment Business, Samsung Electronics Co., Ltd., Suwon, Republic of Korea
| | - Jiyoung Jung
- CT R&D Group, Health & Medical Equipment Business, Samsung Electronics Co., Ltd., Suwon, Republic of Korea
| | - Minkook Cho
- CT R&D Group, Health & Medical Equipment Business, Samsung Electronics Co., Ltd., Suwon, Republic of Korea
| | - Kyoung-Yong Lee
- CT R&D Group, Health & Medical Equipment Business, Samsung Electronics Co., Ltd., Suwon, Republic of Korea.
| |
Collapse
|
7
|
Noël G, Thariat J, Antoni D. [Uncertainties in the current concept of radiotherapy planning target volume]. Cancer Radiother 2020; 24:667-675. [PMID: 32828670 DOI: 10.1016/j.canrad.2020.06.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Revised: 06/01/2020] [Accepted: 06/07/2020] [Indexed: 12/12/2022]
Abstract
The planning target volume is an essential notion in radiotherapy, that requires a new conceptualization. Indeed, the variability and diversity of the uncertainties involved or improved with the development of the new modern technologies and devices in radiotherapy suggest that random and systematic errors cannot be currently generalized. This article attempts to discuss these various uncertainties and tries to demonstrate that a redefinition of the concept of planning target volume toward its personalization for each patient and the robustness notion are likely an improvement basis to take into account the radiotherapy uncertainties.
Collapse
Affiliation(s)
- G Noël
- Service d'oncologie radiothérapie, Institut de cancérologie Strasbourg Europe (Icans), 17, rue Albert-Calmette, 67033 Strasbourg, France.
| | - J Thariat
- Département de radiothérapie, centre François-Baclesse, 3, avenue General-Harris, 14000 Caen, France; Association Advance Resource Centre for Hadrontherapy in Europe (Archade), 3, avenue General-Harris, 14000 Caen, France; Laboratoire de physique corpusculaire, Institut national de physique nucléaire et de physique des particules (IN2P3), 6, boulevard Maréchal-Juin, 14000 Caen, France; École nationale supérieure d'ingénieurs de Caen (ENSICaen), 6, boulevard Maréchal-Juin, CS 45053 14050 Caen cedex 4, France; Centre national de la recherche scientifique (CNRS), UMR 6534, 6, boulevard Maréchal-Juin, 14000 Caen, France; Université de Caen Normandie (Unicaen), esplanade de la Paix, CS 14032, 14032 Caen, France
| | - D Antoni
- Service d'oncologie radiothérapie, Institut de cancérologie Strasbourg Europe (Icans), 17, rue Albert-Calmette, 67033 Strasbourg, France
| |
Collapse
|
8
|
Comparison of different methods for lung immobilization in an animal model. Radiother Oncol 2020; 150:151-158. [PMID: 32580000 DOI: 10.1016/j.radonc.2020.06.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 05/28/2020] [Accepted: 06/17/2020] [Indexed: 12/25/2022]
Abstract
BACKGROUND AND PURPOSE Respiratory-induced motion introduces uncertainties in the delivery of dose in radiotherapy treatments. Various methods are used clinically, e.g. breath-holding, while there is limited experience with other methods such as apneic oxygenation and high frequency jet ventilation (HFJV). This study aims to compare the latter approaches for lung immobilization and their clinical impact on gas exchange in an animal model. MATERIALS AND METHODS Two radiopaque tumor surrogate markers (TSM) were placed in the central (cTSM) and peripheral (dTSM) regions of the lungs in 9 anesthetized and muscle relaxed pigs undergoing 3 ventilatory interventions (1) HFJV at rates of 200 (JV200), 300 (JV300) and 400 (JV400) min-1; (2) apnea at continuous positive airway pressure (CPAP) levels of 0, 8 and 16 cmH2O; (3) conventional mechanical ventilation (CMV) as reference mode. cTSM and dTSM were visualized using fluoroscopy and their coordinates were computed. The ventilatory pattern was registered, and oxygen and carbon dioxide (pCO2) partial pressures were measured. RESULTS The highest range of TSM motion, and ventilation was found during CMV, the lowest during apnea. During HFJV the amount of motion varied inversely with increasing frequency. The reduction of TSM motion at JV300, JV400 and all CPAP levels came at the cost of increased pCO2, however the relatively low frequency of 200 min-1 for HFJV was the only ventilatory setting that enabled adequate CO2 removal. CONCLUSION In this model, HFJV at 200 min-1 was the best compromise between immobilization and gas exchange for sessions of 10-min duration.
Collapse
|
9
|
Bertholet J, Knopf A, Eiben B, McClelland J, Grimwood A, Harris E, Menten M, Poulsen P, Nguyen DT, Keall P, Oelfke U. Real-time intrafraction motion monitoring in external beam radiotherapy. Phys Med Biol 2019; 64:15TR01. [PMID: 31226704 PMCID: PMC7655120 DOI: 10.1088/1361-6560/ab2ba8] [Citation(s) in RCA: 111] [Impact Index Per Article: 22.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2019] [Revised: 05/10/2019] [Accepted: 06/21/2019] [Indexed: 12/25/2022]
Abstract
Radiotherapy (RT) aims to deliver a spatially conformal dose of radiation to tumours while maximizing the dose sparing to healthy tissues. However, the internal patient anatomy is constantly moving due to respiratory, cardiac, gastrointestinal and urinary activity. The long term goal of the RT community to 'see what we treat, as we treat' and to act on this information instantaneously has resulted in rapid technological innovation. Specialized treatment machines, such as robotic or gimbal-steered linear accelerators (linac) with in-room imaging suites, have been developed specifically for real-time treatment adaptation. Additional equipment, such as stereoscopic kilovoltage (kV) imaging, ultrasound transducers and electromagnetic transponders, has been developed for intrafraction motion monitoring on conventional linacs. Magnetic resonance imaging (MRI) has been integrated with cobalt treatment units and more recently with linacs. In addition to hardware innovation, software development has played a substantial role in the development of motion monitoring methods based on respiratory motion surrogates and planar kV or Megavoltage (MV) imaging that is available on standard equipped linacs. In this paper, we review and compare the different intrafraction motion monitoring methods proposed in the literature and demonstrated in real-time on clinical data as well as their possible future developments. We then discuss general considerations on validation and quality assurance for clinical implementation. Besides photon RT, particle therapy is increasingly used to treat moving targets. However, transferring motion monitoring technologies from linacs to particle beam lines presents substantial challenges. Lessons learned from the implementation of real-time intrafraction monitoring for photon RT will be used as a basis to discuss the implementation of these methods for particle RT.
Collapse
Affiliation(s)
- Jenny Bertholet
- Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS
Foundation Trust, London, United
Kingdom
- Author to whom any correspondence should be
addressed
| | - Antje Knopf
- Department of Radiation Oncology,
University Medical Center
Groningen, University of Groningen, The
Netherlands
| | - Björn Eiben
- Department of Medical Physics and Biomedical
Engineering, Centre for Medical Image Computing, University College London, London,
United Kingdom
| | - Jamie McClelland
- Department of Medical Physics and Biomedical
Engineering, Centre for Medical Image Computing, University College London, London,
United Kingdom
| | - Alexander Grimwood
- Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS
Foundation Trust, London, United
Kingdom
| | - Emma Harris
- Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS
Foundation Trust, London, United
Kingdom
| | - Martin Menten
- Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS
Foundation Trust, London, United
Kingdom
| | - Per Poulsen
- Department of Oncology, Aarhus University Hospital, Aarhus,
Denmark
| | - Doan Trang Nguyen
- ACRF Image X Institute, University of Sydney, Sydney,
Australia
- School of Biomedical Engineering,
University of Technology
Sydney, Sydney, Australia
| | - Paul Keall
- ACRF Image X Institute, University of Sydney, Sydney,
Australia
| | - Uwe Oelfke
- Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS
Foundation Trust, London, United
Kingdom
| |
Collapse
|
10
|
Reynolds T, Shieh C, Keall PJ, O'Brien RT. Dual cardiac and respiratory gated thoracic imaging via adaptive gantry velocity and projection rate modulation on a linear accelerator: A Proof‐of‐Concept Simulation Study. Med Phys 2019; 46:4116-4126. [DOI: 10.1002/mp.13670] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2018] [Revised: 05/28/2019] [Accepted: 06/10/2019] [Indexed: 12/30/2022] Open
Affiliation(s)
- Tess Reynolds
- Faculty of Medicine and Health ACRF Image X Institute, The University of Sydney Sydney NSW 2006Australia
| | - Chun‐Chien Shieh
- Faculty of Medicine and Health ACRF Image X Institute, The University of Sydney Sydney NSW 2006Australia
| | - Paul J. Keall
- Faculty of Medicine and Health ACRF Image X Institute, The University of Sydney Sydney NSW 2006Australia
| | - Ricky T. O'Brien
- Faculty of Medicine and Health ACRF Image X Institute, The University of Sydney Sydney NSW 2006Australia
| |
Collapse
|
11
|
|
12
|
Schwarz M, Cattaneo GM, Marrazzo L. Geometrical and dosimetrical uncertainties in hypofractionated radiotherapy of the lung: A review. Phys Med 2017; 36:126-139. [DOI: 10.1016/j.ejmp.2017.02.011] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2016] [Revised: 12/23/2016] [Accepted: 02/14/2017] [Indexed: 12/25/2022] Open
|
13
|
Arai TJ, Nofiele J, Madhuranthakam AJ, Yuan Q, Pedrosa I, Chopra R, Sawant A. Characterizing spatiotemporal information loss in sparse-sampling-based dynamic MRI for monitoring respiration-induced tumor motion in radiotherapy. Med Phys 2017; 43:2807-2820. [PMID: 27277029 DOI: 10.1118/1.4948684] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
PURPOSE Sparse-sampling and reconstruction techniques represent an attractive strategy to achieve faster image acquisition speeds, while maintaining adequate spatial resolution and signal-to-noise ratio in rapid magnetic resonance imaging (MRI). The authors investigate the use of one such sequence, broad-use linear acquisition speed-up technique (k-t BLAST) in monitoring tumor motion for thoracic and abdominal radiotherapy and examine the potential trade-off between increased sparsification (to increase imaging speed) and the potential loss of "true" information due to greater reliance on a priori information. METHODS Lung tumor motion trajectories in the superior-inferior direction, previously recorded from ten lung cancer patients, were replayed using a motion phantom module driven by an MRI-compatible motion platform. Eppendorf test tubes filled with water which serve as fiducial markers were placed in the phantom. The modeled rigid and deformable motions were collected in a coronal image slice using balanced fast field echo in conjunction with k-t BLAST. Root mean square (RMS) error was used as a metric of spatial accuracy as measured trajectories were compared to input data. The loss of spatial information was characterized for progressively increasing acceleration factor from 1 to 16; the resultant sampling frequency was increased approximately from 2.5 to 19 Hz when the principal direction of the motion was set along frequency encoding direction. In addition to the phantom study, respiration-induced tumor motions were captured from two patients (kidney tumor and lung tumor) at 13 Hz over 49 s to demonstrate the impact of high speed motion monitoring over multiple breathing cycles. For each subject, the authors compared the tumor centroid trajectory as well as the deformable motion during free breathing. RESULTS In the rigid and deformable phantom studies, the RMS error of target tracking at the acquisition speed of 19 Hz was approximately 0.3-0.4 mm, which was smaller than the reconstructed pixel resolution of 0.67 mm. In the patient study, the dynamic 2D MRI enabled the monitoring of cycle-to-cycle respiratory variability present in the tumor position. It was seen that the range of centroid motion as well as the area covered due to target motion during each individual respiratory cycle was underestimated compared to the entire motion range observed over multiple breathing cycles. CONCLUSIONS The authors' initial results demonstrate that sparse-sampling- and reconstruction-based dynamic MRI can be used to achieve adequate image acquisition speeds without significant information loss for the task of radiotherapy guidance. Such monitoring can yield spatial and temporal information superior to conventional offline and online motion capture methods used in thoracic and abdominal radiotherapy.
Collapse
Affiliation(s)
- Tatsuya J Arai
- Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, Texas 75390
| | - Joris Nofiele
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas 75390
| | - Ananth J Madhuranthakam
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas 75390 and Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas 75390
| | - Qing Yuan
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas 75390
| | - Ivan Pedrosa
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas 75390 and Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas 75390
| | - Rajiv Chopra
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas 75390 and Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas 75390
| | - Amit Sawant
- Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, Texas 75390; Department of Radiology, UT Southwestern Medical Center, Dallas, Texas 75390; and Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland, 21201
| |
Collapse
|