1
|
Tham BZ, Aleman DM, Nordström H, Nygren N, Coolens C. Treatment Planning Methods for Dose Painting by Numbers Treatment in Gamma Knife Radiosurgery. Adv Radiat Oncol 2024; 9:101534. [PMID: 39104874 PMCID: PMC11298584 DOI: 10.1016/j.adro.2024.101534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Accepted: 03/16/2024] [Indexed: 08/07/2024] Open
Abstract
Purpose Dose painting radiation therapy delivers a nonuniform dose to tumors to account for heterogeneous radiosensitivity. With recent and ongoing development of Gamma Knife machines making large-volume brain tumor treatments more practical, it is increasingly feasible to deliver dose painting treatments. The increased prescription complexity means automated treatment planning is greatly beneficial, and the impact of dose painting on stereotactic radiosurgery (SRS) plan quality has not yet been studied. This research investigates the plan quality achievable for Gamma Knife SRS dose painting treatments when using optimization techniques and automated isocenter placement in treatment planning. Methods and Materials Dose painting prescription functions with varying parameters were applied to convert voxel image intensities to prescriptions for 10 sample cases. To study achievable plan quality and optimization, clinically placed isocenters were used with each dose painting prescription and optimized using a semi-infinite linear programming formulation. To study automated isocenter placement, a grassfire sphere-packing algorithm and a clinically available Leksell gamma plan isocenter fill algorithm were used. Plan quality for each optimized treatment plan was measured with dose painting SRS metrics. Results Optimization can be used to find high quality dose painting plans, and plan quality is affected by the dose painting prescription method. Polynomial function prescriptions show more achievable plan quality than sigmoid function prescriptions even with high mean dose boost. Automated isocenter placement is shown as a feasible method for dose painting SRS treatment, and increasing the number of isocenters improves plan quality. The computational solve time for optimization is within 5 minutes in most cases, which is suitable for clinical planning. Conclusions The impact of dose painting prescription method on achievable plan quality is quantified in this study. Optimization and automated isocenter placement are shown as possible treatment planning methods to obtain high quality plans.
Collapse
Affiliation(s)
- Benjamin Z. Tham
- Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, Ontario, Canada
| | - Dionne M. Aleman
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario, Canada
| | | | | | - Catherine Coolens
- Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, Ontario, Canada
| |
Collapse
|
2
|
Tham BZ, Aleman D, Nordström H, Nygren N, Coolens C. Plan Assessment Metrics for Dose Painting in Stereotactic Radiosurgery. Adv Radiat Oncol 2023; 8:101281. [PMID: 37415903 PMCID: PMC10320410 DOI: 10.1016/j.adro.2023.101281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Accepted: 05/23/2023] [Indexed: 07/08/2023] Open
Abstract
Purpose As radiation therapy treatment precision increases with advancements in imaging and radiation delivery, dose painting treatment becomes increasingly feasible, where targets receive a nonuniform radiation dose. The high precision of stereotactic radiosurgery (SRS) makes it a good candidate for dose painting treatments, but no suitable metrics to assess dose painting SRS plans exist. Existing dose painting assessment metrics weigh target overdose and underdose equally but are unsuited for SRS plans, which typically avoid target underdose more. Current SRS metrics also prioritize reducing healthy tissue dose through selectivity and dose fall-off, and these metrics assume single prescriptions. We propose a set of metrics for dose painting SRS that would meet clinical needs and are calculated with nonuniform dose painting prescriptions. Methods and Materials Sample dose painting SRS prescriptions are first created from Gamma Knife SRS cases, apparent diffusion coefficient magnetic resonance images, and various image-to-prescription functions. Treatment plans are found through semi-infinite linear programming optimization and using clinically determined isocenters, then assessed with existing and proposed metrics. Modified versions of SRS metrics are proposed, including coverage, selectivity, conformity, efficiency, and gradient indices. Quality factor, a current dose painting metric, is applied both without changes and with modifications. A new metric, integral dose ratio, is proposed as a measure of target overdose. Results The merits of existing and modified metrics are demonstrated and discussed. A modified conformity index using mean or minimum prescription dose would be suitable for dose painting SRS with integral or maximum boost methods, respectively. Either modified efficiency index is a suitable replacement for the existing gradient index. Conclusions The proposed modified SRS metrics are appropriate measures of plan quality for dose painting SRS plans and have the advantage of giving equal values as the original SRS metrics when applied to single-prescription plans.
Collapse
Affiliation(s)
- Benjamin Z. Tham
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario, Canada
| | - Dionne Aleman
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario, Canada
| | | | | | - Catherine Coolens
- Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, Ontario, Canada
| |
Collapse
|
3
|
Almhagen E, Dasu A, Johansson S, Traneus E, Ahnesjö A. Plan robustness and RBE influence for proton dose painting by numbers for head and neck cancers. Phys Med 2023; 115:103157. [PMID: 37939480 DOI: 10.1016/j.ejmp.2023.103157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 08/25/2023] [Accepted: 09/26/2023] [Indexed: 11/10/2023] Open
Abstract
PURPOSE To investigate the feasibility of dose painting by numbers (DPBN) with respect to robustness for proton therapy for head and neck cancers (HNC), and to study the influence of variable RBE on the TCP and OAR dose burden. METHODS AND MATERIALS Data for 19 patients who have been scanned pretreatment with PET-FDG and subsequently treated with photon therapy were used in the study. A dose response model developed for photon therapy was implemented in a TPS, allowing DPBN plans to be created. Conventional homogeneous dose and DPBN plans were created for each patient, optimized with either fixed RBE = 1.1 or a variable RBE model. Robust optimization was used to create clinically acceptable plans. To estimate the maximum potential loss in TCP due to actual SUV variations from the pre-treatment imaging, we applied a test case with randomized SUV distribution. RESULTS Regardless of the use of variable RBE for optimization or evaluation, a statistically significant increase (p < 0.001) in TCP was found for DPBN plans as compared to homogeneous dose plans. Randomizing the SUV distribution decreased the TCP for all plans. A correlation between TCP increase and variance of the SUV distribution and target volume was also found. CONCLUSION DPBN for protons and HNC is feasible and could lead to a TCP gain. Risks associated with the temporal variation of SUV distributions could be mitigated by imposing minimum doses to targets. The correlation found between TCP increase and SUV variance and target volume may be used for patient selection.
Collapse
Affiliation(s)
- Erik Almhagen
- Medical Radiation Sciences, Department of Immunology, Genetics and Pathology, Uppsala University, Akademiska Sjukhuset, Uppsala, Sweden; The Skandion Clinic, Uppsala, Sweden.
| | - Alexandru Dasu
- Medical Radiation Sciences, Department of Immunology, Genetics and Pathology, Uppsala University, Akademiska Sjukhuset, Uppsala, Sweden; The Skandion Clinic, Uppsala, Sweden
| | - Silvia Johansson
- Divison of Oncology, Department of Immunology, Genetics and Pathology, Uppsala University Hospital, Uppsala, Sweden
| | | | - Anders Ahnesjö
- Medical Radiation Sciences, Department of Immunology, Genetics and Pathology, Uppsala University, Akademiska Sjukhuset, Uppsala, Sweden
| |
Collapse
|
4
|
Pang Y, Kosmin M, Li Z, Deng X, Li Z, Li X, Zhang Y, Royle G, Manolopoulos S. Isotoxic dose escalated radiotherapy for glioblastoma based on diffusion-weighted MRI and tumor control probability-an in-silico study. Br J Radiol 2023; 96:20220384. [PMID: 37102792 PMCID: PMC10230387 DOI: 10.1259/bjr.20220384] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 02/19/2023] [Accepted: 03/03/2023] [Indexed: 04/28/2023] Open
Abstract
OBJECTIVES Glioblastoma (GBM) is the most common malignant primary brain tumor with local recurrence after radiotherapy (RT), the most common mode of failure. Standard RT practice applies the prescription dose uniformly across tumor volume disregarding radiological tumor heterogeneity. We present a novel strategy using diffusion-weighted (DW-) MRI to calculate the cellular density within the gross tumor volume (GTV) in order to facilitate dose escalation to a biological target volume (BTV) to improve tumor control probability (TCP). METHODS The pre-treatment apparent diffusion coefficient (ADC) maps derived from DW-MRI of ten GBM patients treated with radical chemoradiotherapy were used to calculate the local cellular density based on published data. Then, a TCP model was used to calculate TCP maps from the derived cell density values. The dose was escalated using a simultaneous integrated boost (SIB) to the BTV, defined as the voxels for which the expected pre-boost TCP was in the lowest quartile of the TCP range for each patient. The SIB dose was chosen so that the TCP in the BTV increased to match the average TCP of the whole tumor. RESULTS By applying a SIB of between 3.60 Gy and 16.80 Gy isotoxically to the BTV, the cohort's calculated TCP increased by a mean of 8.44% (ranging from 7.19 to 16.84%). The radiation dose to organ at risk is still under their tolerance. CONCLUSIONS Our findings indicate that TCPs of GBM patients could be increased by escalating radiation doses to intratumoral locations guided by the patient's biology (i.e., cellularity), moreover offering the possibility for personalized RT GBM treatments. ADVANCES IN KNOWLEDGE A personalized and voxel level SIB radiotherapy method for GBM is proposed using DW-MRI, which can increase the tumor control probability and maintain organ at risk dose constraints.
Collapse
Affiliation(s)
- Yaru Pang
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London, United Kingdom
| | | | - Zhuangling Li
- Department of Radiation Oncology, Shenzhen People's Hospital, Shenzhen, China
| | - Xiaonian Deng
- Department of Radiation Oncology, Shenzhen People's Hospital, Shenzhen, China
| | - Zihuang Li
- Department of Radiation Oncology, Shenzhen People's Hospital, Shenzhen, China
| | - Xianming Li
- Department of Radiation Oncology, Shenzhen People's Hospital, Shenzhen, China
| | - Ying Zhang
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London, United Kingdom
| | - Gary Royle
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London, United Kingdom
| | | |
Collapse
|
5
|
Buti G, Shusharina N, Ajdari A, Sterpin E, Bortfeld T. Exploring trade-offs in treatment planning for brain tumor cases with a probabilistic definition of the clinical target volume. Med Phys 2023; 50:410-423. [PMID: 36354283 DOI: 10.1002/mp.16097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 10/20/2022] [Accepted: 10/26/2022] [Indexed: 11/12/2022] Open
Abstract
PURPOSE This study demonstrates how a novel probabilistic clinical target volume (CTV) concept-the clinical target distribution (CTD)-can be used to navigate the trade-off between target coverage and organ sparing with a semi-interactive treatment planning approach. METHODS Two probabilistic treatment planning methods are presented that use tumor probabilities to balance tumor control with organ-at-risk (OAR) sparing. The first method explores OAR dose reduction by systematically discarding x % $x\%$ of CTD voxels with an unfavorable dose-to-probability ratio from the minimum dose coverage objective. The second method sequentially expands the target volume from the GTV edge, calculating the CTD coverage versus OAR sparing trade-off after dosing each expansion. Each planning method leads to estimated levels of tumor control under specific statistical models of tumor infiltration: an independent tumor islets model and contiguous circumferential tumor growth model. The methods are illustrated by creating proton therapy treatment plans for two glioblastoma patients with the clinical goal of sparing the hippocampus and brainstem. For probabilistic plan evaluation, the concept of a dose-expected-volume histogram is introduced, which plots the dose to the expected tumor volume ⟨ v ⟩ $\langle v \rangle$ considering tumor probabilities. RESULTS Both probabilistic planning approaches generate a library of treatment plans to interactively navigate the planning trade-offs. In the first probabilistic approach, a significant reduction of hippocampus dose could be achieved by excluding merely 1% of CTD voxels without compromising expected tumor control probability (TCP) or CTD coverage: the hippocampus D 2 % $D_{2\%}$ dose reduces with 9.5 and 5.3 Gy for Patient 1 and 2, while the TCP loss remains below 1%. Moreover, discarding up to 10% of the CTD voxels does not significantly diminish the expected CTD dose, even though evaluation with a binary volume suggests poor CTD coverage. In the second probabilistic approach, the expected CTD D ⟨ 98 % ⟩ $D_{\langle 98\%\rangle }$ and TCP depend more strongly on the extent of the high-dose region: the target volume margin cannot be reduced by more than 2 mm if one aims at keeping the expected CTD D ⟨ 98 % ⟩ $D_{\langle 98\%\rangle }$ loss and TCP loss under 1 Gy and 2%, respectively. Therefore, there is less potential for improved OAR sparing without compromising TCP or expected CTD coverage. CONCLUSIONS This study proposes and implements treatment planning strategies to explore trade-offs using tumor probabilities.
Collapse
Affiliation(s)
- Gregory Buti
- Institute of Experimental and Clinical Research, Center of Molecular Imaging, Radiotherapy and Oncology, Brussels, Belgium.,Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, Division of Radiation Biophysics, Boston, Massachusetts, USA
| | - Nadya Shusharina
- Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, Division of Radiation Biophysics, Boston, Massachusetts, USA
| | - Ali Ajdari
- Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, Division of Radiation Biophysics, Boston, Massachusetts, USA
| | - Edmond Sterpin
- Institute of Experimental and Clinical Research, Center of Molecular Imaging, Radiotherapy and Oncology, Brussels, Belgium.,KU Leuven, Department of Oncology, Laboratory of Experimental Radiotherapy, Leuven, Belgium
| | - Thomas Bortfeld
- Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, Division of Radiation Biophysics, Boston, Massachusetts, USA
| |
Collapse
|
6
|
Fredén E, Tilly D, Ahnesjö A. Adaptive dose painting for prostate cancer. Front Oncol 2022; 12:973067. [PMID: 36237318 PMCID: PMC9552323 DOI: 10.3389/fonc.2022.973067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2022] [Accepted: 09/08/2022] [Indexed: 11/30/2022] Open
Abstract
Purpose Dose painting (DP) is a radiation therapy (RT) strategy for patients with heterogeneous tumors delivering higher dose to radiation resistant regions and less to sensitive ones, thus aiming to maximize tumor control with limited side effects. The success of DP treatments is influenced by the spatial accuracy in dose delivery. Adaptive RT (ART) workflows can reduce the overall geometric dose delivery uncertainty. The purpose of this study is to dosimetrically compare ART and non-adaptive conventional RT workflows for delivery of DP prescriptions in the treatment of prostate cancer (PCa). Materials and methods We performed a planning and treatment simulation study of four study arms. Adaptive and conventional workflows were tested in combination with DP and Homogeneous dose. We used image data from 5 PCa patients that had been treated on the Elekta Unity MR linac; the patients had been imaged in treatment position before each treatment fraction (7 in total). The local radiation sensitivity from apparent diffusion coefficient maps of 15 high-risk PCa patients was modelled in a previous study. these maps were used as input for optimization of DP plans aiming for maximization of tumor control probability (TCP) under rectum dose constraints. A range of prostate doses were planned for the homogeneous arms. Adaptive plans were replanned based on the anatomy-of-the-day, whereas conventional plans were planned using a pre-treatment image and subsequently recalculated on the anatomy-of-the-day. The dose from 7 fractions was accumulated using dose mapping. The endpoints studied were the TCP and dose-volume histogram metrics for organs at risk. Results Accumulated DP doses (adaptive and conventional) resulted in high TCP, between 96-99%. The largest difference between adaptive and conventional DP was 2.6 percentage points (in favor of adaptive DP). An analysis of the dose per fraction revealed substantial target misses for one patient in the conventional workflow that—if systematic—could jeopardize the TCP. Compared to homogeneous prescriptions with equal mean prostate dose, DP resulted in slightly higher TCP. Conclusion Compared to homogeneous dose, DP maintains or marginally increases the TCP. Adaptive DP workflows could avoid target misses compared to conventional workflows.
Collapse
Affiliation(s)
- Emil Fredén
- Department of Oncology, Södersjukhuset, Stockholm, Sweden
- *Correspondence: Emil Fredén,
| | - David Tilly
- Department of Genetics, Immunology and Pathology, Medical Radiation Sciences, Uppsala University, Uppsala, Sweden
- Department of Medical Physics, Uppsala University Hospital, Uppsala, Sweden
| | - Anders Ahnesjö
- Department of Genetics, Immunology and Pathology, Medical Radiation Sciences, Uppsala University, Uppsala, Sweden
| |
Collapse
|
7
|
Jiménez-Ortega E, Agüera R, Ureba A, Balcerzyk M, Wals-Zurita A, García-Gómez FJ, Leal A. Implications of the Harmonization of [ 18F]FDG-PET/CT Imaging for Response Assessment of Treatment in Radiotherapy Planning. Tomography 2022; 8:1097-1112. [PMID: 35448724 PMCID: PMC9031488 DOI: 10.3390/tomography8020090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 04/06/2022] [Accepted: 04/07/2022] [Indexed: 11/16/2022] Open
Abstract
The purpose of this work is to present useful recommendations for the use of [18F]FDG-PET/CT imaging in radiotherapy planning and monitoring under different versions of EARL accreditation for harmonization of PET devices. A proof-of-concept experiment designed on an anthropomorphic phantom was carried out to establish the most suitable interpolation methods of the PET images in the different steps of the planning procedure. Based on PET/CT images obtained by using these optimal interpolations for the old EARL accreditation (EARL1) and for the new one (EARL2), the treatment plannings of representative actual clinical cases were calculated, and the clinical implications of the resulting differences were analyzed. As expected, EARL2 provided smaller volumes with higher resolution than EARL1. The increase in the size of the reconstructed volumes with EARL1 accreditation caused high doses in the organs at risk and in the regions adjacent to the target volumes. EARL2 accreditation allowed an improvement in the accuracy of the PET imaging precision, allowing more personalized radiotherapy. This work provides recommendations for those centers that intend to benefit from the new accreditation, EARL2, and can help build confidence of those that must continue working under the EARL1 accreditation.
Collapse
Affiliation(s)
- Elisa Jiménez-Ortega
- Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, 41009 Seville, Spain; (E.J.-O.); (R.A.); (M.B.)
- Instituto de Biomedicina de Sevilla, IBiS, 41013 Seville, Spain;
| | - Raquel Agüera
- Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, 41009 Seville, Spain; (E.J.-O.); (R.A.); (M.B.)
| | - Ana Ureba
- Instituto de Biomedicina de Sevilla, IBiS, 41013 Seville, Spain;
- Medical Radiation Physics, Department of Physics, Stockholm University, 114 21 Stockholm, Sweden
| | - Marcin Balcerzyk
- Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, 41009 Seville, Spain; (E.J.-O.); (R.A.); (M.B.)
- Centro Nacional de Aceleradores (CNA), Universidad de Sevilla, Junta de Andalucía, Consejo Superior de Investigaciones Científicas (CSIC), 41092 Seville, Spain
| | - Amadeo Wals-Zurita
- Hospital Universitario Virgen Macarena, Servicio de Radioterapia, 41009 Seville, Spain;
| | | | - Antonio Leal
- Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, 41009 Seville, Spain; (E.J.-O.); (R.A.); (M.B.)
- Instituto de Biomedicina de Sevilla, IBiS, 41013 Seville, Spain;
| |
Collapse
|
8
|
Pang Y, Wang H, Li H. Medical Imaging Biomarker Discovery and Integration Towards AI-Based Personalized Radiotherapy. Front Oncol 2022; 11:764665. [PMID: 35111666 PMCID: PMC8801459 DOI: 10.3389/fonc.2021.764665] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Accepted: 11/29/2021] [Indexed: 12/22/2022] Open
Abstract
Intensity-modulated radiation therapy (IMRT) has been used for high-accurate physical dose distribution sculpture and employed to modulate different dose levels into Gross Tumor Volume (GTV), Clinical Target Volume (CTV) and Planning Target Volume (PTV). GTV, CTV and PTV can be prescribed at different dose levels, however, there is an emphasis that their dose distributions need to be uniform, despite the fact that most types of tumour are heterogeneous. With traditional radiomics and artificial intelligence (AI) techniques, we can identify biological target volume from functional images against conventional GTV derived from anatomical imaging. Functional imaging, such as multi parameter MRI and PET can be used to implement dose painting, which allows us to achieve dose escalation by increasing doses in certain areas that are therapy-resistant in the GTV and reducing doses in less aggressive areas. In this review, we firstly discuss several quantitative functional imaging techniques including PET-CT and multi-parameter MRI. Furthermore, theoretical and experimental comparisons for dose painting by contours (DPBC) and dose painting by numbers (DPBN), along with outcome analysis after dose painting are provided. The state-of-the-art AI-based biomarker diagnosis techniques is reviewed. Finally, we conclude major challenges and future directions in AI-based biomarkers to improve cancer diagnosis and radiotherapy treatment.
Collapse
Affiliation(s)
- Yaru Pang
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| | - Hui Wang
- Department of Chemical Engineering, University College London, London, United Kingdom
| | - He Li
- Department of Engineering, University of Cambridge, Cambridge, United Kingdom
| |
Collapse
|
9
|
Ferjančič P, van der Heide UA, Ménard C, Jeraj R. Probabilistic target definition and planning in patients with prostate cancer. Phys Med Biol 2021; 66. [PMID: 34644696 DOI: 10.1088/1361-6560/ac2f8a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Accepted: 10/13/2021] [Indexed: 11/11/2022]
Abstract
Intro.Current radiation therapy (RT) planning guidelines handle uncertainties in RT using geometric margins. This approach is simple to use but oversimplifies complex underlying processes and is cumbersome for non-homogeneous dose prescriptions. In this work, we characterize the performance of a novel probabilistic target definition and planning (PTP) approach, which uses voxel-level tumor likelihood information in treatment plan optimization.Methods.We expanded a treatment planning system with probabilistic therapy planning functionality that utilizes non-binary target maps (TM) as voxel-level input to dose plan optimization. Different dose plans were calculated and compared for twelve prostate cancer patients with multiparametric magnetic resonance imaging derived TMs. Dose plans were created using both classical and PTP approaches for uniform and integrated dose boost prescriptions. Dose performance between the different approaches was compared using dose benchmarks on target and organ-at-risk (OAR) volumes.Results.Over all dose metrics, PTP was shown to be comparable to classical planning. For plans of uniform dose prescription, the PTP approach created plans within 1 Gy of the classical planning approach across all dose metrics, with no significant differences (p > 0.2). For plans with the integrated dose boost, PTP plans exhibited higher dose heterogeneity, but still showed target doses comparable to the classical approach, without increasing doses to OAR.Conclusion.In this work we introduce direct incorporation of probabilistic target definition into treatment planning. This treatment planning approach can produce both uniform dose plans and plans with integrated dose boosts that are comparable to ones created using classical dose planning. PTP is a flexible way to optimize external beam radiotherapy, as it is not limited by the use of margins. PTP can produce dose plans equivalent to classical planning, while also allows for greater versatility in dose prescription and direct incorporation of patient target definition uncertainty into treatment planning.
Collapse
Affiliation(s)
- Peter Ferjančič
- Department of Medical Physics, Wisconsin Institutes for Medical Research, 1111 Highland Ave, Room 7033, Madison, WI 53705, United States of America
| | | | - Cynthia Ménard
- Department of Radiation Oncology, Centre Hospitalier de l'Université de Montréal (CHUM), Canada
| | - Robert Jeraj
- Department of Medical Physics, Wisconsin Institutes for Medical Research, 1111 Highland Ave, Room 7033, Madison, WI 53705, United States of America
| |
Collapse
|
10
|
Fransson S, Tilly D, Ahnesjö A, Nyholm T, Strand R. Intrafractional motion models based on principal components in Magnetic Resonance guided prostate radiotherapy. PHYSICS & IMAGING IN RADIATION ONCOLOGY 2021; 20:17-22. [PMID: 34660917 PMCID: PMC8502906 DOI: 10.1016/j.phro.2021.09.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 09/15/2021] [Accepted: 09/15/2021] [Indexed: 11/18/2022]
Abstract
Background and purpose Devices that combine an MR-scanner with a Linac for radiotherapy, referred to as MR-Linac systems, introduce the possibility to acquire high resolution images prior and during treatment. Hence, there is a possibility to acquire individualised learning sets for motion models for each fraction and the construction of intrafractional motion models. We investigated the feasibility for a principal component analysis (PCA) based, intrafractional motion model of the male pelvic region. Materials and methods 4D-scans of nine healthy male volunteers were utilized, FOV covering the entire pelvic region including prostate, bladder and rectum with manual segmentation of each organ at each time frame. Deformable image registration with an optical flow algorithm was performed for each subject with the first time frame as reference. PCA was performed on a subset of the resulting displacement vector fields to construct individualised motion models evaluated on the remaining fields. Results The registration algorithm produced accurate registration result, in general DICE overlap >0.95 across all time frames. Cumulative variance of the eigen values from the PCA showed that 50% or more of the motion is explained in the first component for all subjects. However, the size and direction for the components differed between subjects. Adding more than two components did not improve the accuracy significantly and the model was able to explain motion down to about 1 mm. Conclusions An individualised intrafractional male pelvic motion model is feasible. Geometric accuracy was about 1 mm based on 1–2 principal components.
Collapse
Affiliation(s)
- Samuel Fransson
- Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
- Department of Medical Physics, Akademiska Hospital, Uppsala, Sweden
- Corresponding author at: Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.
| | - David Tilly
- Department of Medical Physics, Akademiska Hospital, Uppsala, Sweden
- Elekta Instruments AB, Stockholm, Sweden
- Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden
| | - Anders Ahnesjö
- Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
- Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden
| | - Tufve Nyholm
- Department of Radiation Sciences, Umeå University, Umeå, Sweden
| | - Robin Strand
- Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
- Department of Information Technology, Uppsala University, Uppsala, Sweden
| |
Collapse
|
11
|
Leleu T, Bastit V, Doré M, Kammerer E, Florescu C, Alfonsi M, Troussier I, Bensadoun RJ, Biau J, Blais E, Coutte A, Deberne M, Wiazzane N, Dupin C, Faivre JC, Giraud P, Graff P, Guihard S, Huguet F, Janoray G, Liem X, Pointreau Y, Racadot S, Schick U, Servagi-Vernat S, Sun XS, Thureau S, Villa J, Vulquin N, Wong S, Patron V, Thariat J. Histosurgical mapping of endoscopic endonasal surgery of sinonasal tumours to improve radiotherapy guidance. Cancer Radiother 2021; 26:440-444. [PMID: 34175228 DOI: 10.1016/j.canrad.2021.06.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 05/21/2021] [Accepted: 06/01/2021] [Indexed: 11/27/2022]
Abstract
PURPOSE Endoscopic endonasal surgery (EES) is becoming a standard for most malignant sinonasal tumours. Margin analysis after piecemeal resection is complex and optimally relies on accurate histosurgical mapping. Postoperative radiotherapy may be adapted based on margin assessment mapping to reduce the dose to some sinonasal subvolumes. We assessed the use of histosurgical mapping by radiation oncologists (RO). MATERIAL AND METHODS A French practice survey was performed across 29 ENT expert RO (2 did not answer) regarding integration of information on EES, as well as quality of operative and pathology reportsto refine radiotherapy planning after EES. This was assessed through an electronic questionnaire. RESULTS EES was ubiquitously performed in France. Operative and pathology reports yielded accurate description of EES samples according to 66.7% of interviewed RO. Accuracy of margin assessment was however insufficient according to more than 40.0% of RO. Additional margins/biopsies of the operative bed were available in 55.2% (16/29) of the centres. In the absence of additional margins, quality of resection after EES was considered as microscopically incomplete in 48.3% or dubious in 48.3% of RO. As performed, histosurgical mapping allowed radiotherapy dose and volumes adaptation according to 26.3% of RO only. CONCLUSIONS Standardized histosurgical mapping with margin and additional margin analysis could be more systematic. Advantages of accurate EES reporting could be dose painting radiotherapy to further decrease morbidity in sinonasal tumours.
Collapse
Affiliation(s)
- T Leleu
- Department of radiation oncology, centre François-Baclesse, Caen, France
| | - V Bastit
- Department of surgery, centre François-Baclesse, Caen, France
| | | | - E Kammerer
- Department of radiation oncology, centre François-Baclesse, Caen, France
| | - C Florescu
- Department of radiation oncology, centre François-Baclesse, Caen, France
| | | | | | | | - J Biau
- CJP, Clermont-Ferrand, France
| | - E Blais
- AP-HP, Pitié-Salpêtrière, Paris, France
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | - X S Sun
- CHU, Besançon Montbéliard, France
| | | | | | | | | | - V Patron
- Department of ENT surgery, CHU Caen, Caen, France
| | - J Thariat
- Department of radiation oncology, centre François-Baclesse, Caen, France; Unicaen, Normandie Université, Caen, France; GORTEC, France.
| |
Collapse
|
12
|
Shirvani SM, Huntzinger CJ, Melcher T, Olcott PD, Voronenko Y, Bartlett-Roberto J, Mazin S. Biology-guided radiotherapy: redefining the role of radiotherapy in metastatic cancer. Br J Radiol 2021; 94:20200873. [PMID: 33112685 PMCID: PMC7774706 DOI: 10.1259/bjr.20200873] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 09/30/2020] [Accepted: 10/05/2020] [Indexed: 12/14/2022] Open
Abstract
The emerging biological understanding of metastatic cancer and proof-of-concept clinical trials suggest that debulking all gross disease holds great promise for improving patient outcomes. However, ablation of multiple targets with conventional external beam radiotherapy systems is burdensome, which limits investigation and utilization of complete metastatic ablation in the majority of patients with advanced disease. To overcome this logistical hurdle, technical innovation is necessary. Biology-guided radiotherapy (BgRT) is a new external beam radiotherapy delivery modality combining positron emission tomography-computed tomography (PET-CT) with a 6 MV linear accelerator. The key innovation is continuous response of the linear accelerator to outgoing tumor PET emissions with beamlets of radiotherapy at subsecond latency. This allows the deposited dose to track tumors in real time. Multiple new hardware and algorithmic advances further facilitate this low-latency feedback process. By transforming tumors into their own fiducials after intravenous injection of a radiotracer, BgRT has the potential to enable complete metastatic ablation in a manner efficient for a single patient and scalable to entire populations with metastatic disease. Future trends may further enhance the utility of BgRT in the clinic as this technology dovetails with other innovations in radiotherapy, including novel dose painting and fractionation schemes, radiomics, and new radiotracers.
Collapse
|
13
|
Chen S, Yan D, Qin A, Maniawski P, Krauss DJ, Wilson GD. Effect of uncertainties in quantitative 18 F-FDG PET/CT imaging feedback for intratumoral dose-response assessment and dose painting by number. Med Phys 2020; 47:5681-5692. [PMID: 32966627 DOI: 10.1002/mp.14482] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 08/09/2020] [Accepted: 08/18/2020] [Indexed: 01/14/2023] Open
Abstract
PURPOSE Intratumoral dose response can be detected using serial fluoro-2-deoxyglucose-(FDG) positron emission tomography (PET)/computed tomography (CT) imaging feedback during treatment and used to guide adaptive dose painting by number (DPbN). However, to reliably implement this technique, the effect of uncertainties in quantitative PET/CT imaging feedback on tumor voxel dose-response assessment and DPbN needs to be determined and reduced. METHODS Three major uncertainties, induced by (a) PET imaging partial volume effect (PVE) and (b) tumor deformable image registration (DIR), and (c) variation of the time interval between FDG injection and PET image acquisition (TI), were determined using serial FDG-PET/CT images acquired during chemoradiotherapy of 18 head and neck cancer patients. PET imaging PVE was simulated using the discrepancy between with and without iterative deconvolution-based PVE corrections. Effect of tumor DIR uncertainty was simulated using the discrepancy between two DIR algorithms, including one with and one without soft-tissue mechanical correction for the voxel displacement. The effect of TI variation was simulated using linear interpolation on the dual-point PET/CT images. Tumor voxel pretreatment metabolic activity (SUV0 ) and dose-response matrix (DRM) discrepancies induced by each of the three uncertainties were quantified, respectively. Adverse effects of tumor voxel SUV0 and DRM discrepancies on tumor control probability (TCP) in DPbN were assessed. RESULTS Partial volume effect and TI variations of 10 mins induced a mean ± standard deviation (SD) of tumor voxel SUV0 discrepancies to be -0.7% ± 9.2% and 0% ± 4.8%, respectively. Tumor voxel DRM discrepancies induced by PVE, tumor DIR discrepancy, and TI variations were 0.6% ± 8.9%, 1.7% ± 9.1%, and 0% ± 7%, respectively. Partial volume effect induced SUV0 and DRM discrepancies correlated significantly with the tumor shape and FDG uptake heterogeneity. Tumor DIR uncertainty-induced DRM discrepancy correlated significantly with the tumor volume and shrinkage during treatment. Among the three uncertainties, PVE dominated the adverse effects on the TCP, with a mean ± SD of TCP reduction to be 12.7% ± 9.8% for all tumors if no compensation was applied for. CONCLUSIONS Effect of uncertainties in quantitative FDG-PET/CT imaging feedback on intratumoral dose-response quantification was not negligible. These uncertainties primarily caused by PVE and tumor DIR were highly dependent on individual tumor shape, volume, shrinkage during treatment, and pretreatment SUV heterogeneity, which can be managed individually. The adverse effects of these uncertainties could be minimized by using proper PVE corrections and DIR methods and compensated for in the clinical implementation of DPbN.
Collapse
Affiliation(s)
- Shupeng Chen
- Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI, 48073, USA.,Medical Physics, School of Medicine, Wayne State University, Detroit, MI, 48201, USA
| | - Di Yan
- Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI, 48073, USA
| | - An Qin
- Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI, 48073, USA
| | - Piotr Maniawski
- Advanced Molecular Imaging, Philips, Cleveland, OH, 44143, USA
| | - Daniel J Krauss
- Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI, 48073, USA
| | - George D Wilson
- Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI, 48073, USA
| |
Collapse
|
14
|
Her EJ, Haworth A, Reynolds HM, Sun Y, Kennedy A, Panettieri V, Bangert M, Williams S, Ebert MA. Voxel-level biological optimisation of prostate IMRT using patient-specific tumour location and clonogen density derived from mpMRI. Radiat Oncol 2020; 15:172. [PMID: 32660504 PMCID: PMC7805066 DOI: 10.1186/s13014-020-01568-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Accepted: 05/13/2020] [Indexed: 12/24/2022] Open
Abstract
AIMS This study aimed to develop a framework for optimising prostate intensity-modulated radiotherapy (IMRT) based on patient-specific tumour biology, derived from multiparametric MRI (mpMRI). The framework included a probabilistic treatment planning technique in the effort to yield dose distributions with an improved expected treatment outcome compared with uniform-dose planning approaches. METHODS IMRT plans were generated for five prostate cancer patients using two inverse planning methods: uniform-dose to the planning target volume and probabilistic biological optimisation for clinical target volume tumour control probability (TCP) maximisation. Patient-specific tumour location and clonogen density information were derived from mpMRI and geometric uncertainties were incorporated in the TCP calculation. Potential reduction in dose to sensitive structures was assessed by comparing dose metrics of uniform-dose plans with biologically-optimised plans of an equivalent level of expected tumour control. RESULTS The planning study demonstrated biological optimisation has the potential to reduce expected normal tissue toxicity without sacrificing local control by shaping the dose distribution to the spatial distribution of tumour characteristics. On average, biologically-optimised plans achieved 38.6% (p-value: < 0.01) and 51.2% (p-value: < 0.01) reduction in expected rectum and bladder equivalent uniform dose, respectively, when compared with uniform-dose planning. CONCLUSIONS It was concluded that varying the dose distribution within the prostate to take account for each patient's clonogen distribution was feasible. Lower doses to normal structures compared to uniform-dose plans was possible whilst providing robust plans against geometric uncertainties. Further validation in a larger cohort is warranted along with considerations for adaptive therapy and limiting urethral dose.
Collapse
Affiliation(s)
- E J Her
- School of Physics, Mathematics and Computing, University of Western Australia, Perth, Australia.
| | - A Haworth
- Institute of Medical Physics, University of Sydney, Sydney, Australia
| | - H M Reynolds
- The Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Australia.,Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Australia
| | - Y Sun
- The Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Australia.,Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Australia
| | - A Kennedy
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Perth, Australia
| | - V Panettieri
- Alfred Health Radiation Oncology, Melbourne, Australia
| | - M Bangert
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Department of Medical Physics in Radiation Oncology, Heidelberg Institute for Radiation Oncology, Heidelberg, Germany
| | - S Williams
- The Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Australia.,Division of Radiation Oncology and Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne, Australia
| | - M A Ebert
- School of Physics, Mathematics and Computing, University of Western Australia, Perth, Australia.,Department of Radiation Oncology, Sir Charles Gairdner Hospital, Perth, Australia.,5D Clinics, Perth, Australia
| |
Collapse
|
15
|
PET/MRI and genetic intrapatient heterogeneity in head and neck cancers. Strahlenther Onkol 2020; 196:542-551. [PMID: 32211941 DOI: 10.1007/s00066-020-01606-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Accepted: 03/09/2020] [Indexed: 01/24/2023]
Abstract
PURPOSE The relation between functional imaging and intrapatient genetic heterogeneity remains poorly understood. The aim of our study was to investigate spatial sampling and functional imaging by FDG-PET/MRI to describe intrapatient tumour heterogeneity. METHODS Six patients with oropharyngeal cancer were included in this pilot study. Two tumour samples per patient were taken and sequenced by next-generation sequencing covering 327 genes relevant in head and neck cancer. Corresponding regions were delineated on pretherapeutic FDG-PET/MRI images to extract apparent diffusion coefficients and standardized uptake values. RESULTS Samples were collected within the primary tumour (n = 3), within the primary tumour and the involved lymph node (n = 2) as well as within two independent primary tumours (n = 1). Genetic heterogeneity of the primary tumours was limited and most driver gene mutations were found ubiquitously. Slightly increasing heterogeneity was found between primary tumours and lymph node metastases. One private predicted driver mutation within a primary tumour and one in a lymph node were found. However, the two independent primary tumours did not show any shared mutations in spite of a clinically suspected field cancerosis. No conclusive correlation between genetic heterogeneity and heterogeneity of PET/MRI-derived parameters was observed. CONCLUSION Our limited data suggest that single sampling might be sufficient in some patients with oropharyngeal cancer. However, few driver mutations might be missed and, if feasible, spatial sampling should be considered. In two independent primary tumours, both lesions should be sequenced. Our data with a limited number of patients do not support the concept that multiparametric PET/MRI features are useful to guide biopsies for genetic tumour characterization.
Collapse
|
16
|
Thorwarth D. Imaging science and development in modern high-precision radiotherapy. Phys Imaging Radiat Oncol 2019; 12:63-66. [PMID: 33458297 PMCID: PMC7807660 DOI: 10.1016/j.phro.2019.11.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Affiliation(s)
- Daniela Thorwarth
- Section for Biomedical Physics, Department of Radiation Oncology, University of Tübingen, Germany
| |
Collapse
|
17
|
Grönlund E, Almhagen E, Johansson S, Traneus E, Ahnesjö A. Robust maximization of tumor control probability for radicality constrained radiotherapy dose painting by numbers of head and neck cancer. Phys Imaging Radiat Oncol 2019; 12:56-62. [PMID: 33458296 PMCID: PMC7807941 DOI: 10.1016/j.phro.2019.11.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2019] [Revised: 11/10/2019] [Accepted: 11/20/2019] [Indexed: 11/28/2022] Open
Abstract
BACKGROUND AND PURPOSE Radiotherapy with dose painting by numbers (DPBN) needs another approach than conventional margins to ensure a geometrically robust dose coverage for the tumor. This study presents a method to optimize DPBN plans that as opposed to achieve a robust dose distribution instead robustly maximize the tumor control probability (TCP) for patients diagnosed with head and neck cancer. MATERIAL AND METHODS Volumetric-modulated arc therapy (VMAT) plans were optimized with a robust TCP maximizing objective for different dose constraints to the primary clinical target volume (CTVT) for a set of 20 patients. These plans were optimized with minimax optimization together with dose-responses driven by standardized uptake values (SUV) from 18F-fluorodeoxyglucose positron emission tomography (18FDG-PET). The robustness in TCP was evaluated through sampling treatment scenarios with isocenter displacements. RESULTS The average increase in TCP with DPBN compared to a homogeneous dose treatment ranged between 3 and 20 percentage points (p.p.) which depended on the different dose constraints for the CTVT. The median deviation in TCP increase was below 1p.p. for all sampled treatment scenarios versus the nominal plans. The standard deviation of SUV multiplied by the CTVT volume were found to correlate with the TCP gain with R 2 ≥ 0.9. CONCLUSIONS Minimax optimization of DPBN plans yield, based on the presented TCP modelling, a robust increase of the TCP compared to homogeneous dose treatments for head and neck cancers. The greatest TCP gains were found for patients with large and SUV heterogeneous tumors, which may give guidance for patient selection in prospective trials.
Collapse
Affiliation(s)
- Eric Grönlund
- Medical Radiation Sciences, Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden
- Section of Medical Physics, Mälar Hospital, Eskilstuna, Sweden
| | - Erik Almhagen
- Medical Radiation Sciences, Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden
- The Skandion Clinic, Uppsala, Sweden
| | - Silvia Johansson
- Experimental and Clinical Oncology, Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden
- Uppsala University Hospital, Uppsala, Sweden
| | | | - Anders Ahnesjö
- Medical Radiation Sciences, Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden
- Uppsala University Hospital, Uppsala, Sweden
| |
Collapse
|
18
|
Kosztyla R, Raman S, Moiseenko V, Reinsberg SA, Toyota B, Nichol A. Dose-painted volumetric modulated arc therapy of high-grade glioma using 3,4-dihydroxy-6-[ 18F]fluoro-L-phenylalanine positron emission tomography. Br J Radiol 2019; 92:20180901. [PMID: 31017449 DOI: 10.1259/bjr.20180901] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE To determine whether dose painting with volumetric modulated arc therapy for high-grade gliomas using 3,4-dihydroxy-6-[18F]fluoro-l-phenylalanine (18F-FDOPA) positron emission tomography (PET) could achieve dose-escalated coverage of biological target volumes (BTVs) without increasing the dose to cranial organs at risk (OARs). METHODS 10 patients with high-grade gliomas underwent CT, MRI, and 18F-FDOPA PET/CT images for post-operative radiation therapy planning. Two volumetric modulated arc therapy plans were retrospectively generated for each patient: a conventional plan with 60 Gy in 30 fractions to the planning target volume delineated on MRI and a dose-escalated plan with a maximum dose of 80 Gy in 30 fractions to BTVs. BTVs were created by thresholding 18F-FDOPA PET/CT uptake using a linear quadratic model that assumed tracer uptake was linearly related to tumour cell density. The maximum doses and equivalent uniform doses of OARs were compared. RESULTS The median volume of the planning target volume receiving at least 95% of the prescribed dose (V 95%) was 99.6% with and 99.5% without dose painting. The median V 95% was >99.2% for BTVs. The maximum doses and equivalent uniform doses to the OARs did not differ significantly between the conventional and dose-painted plans. CONCLUSION Using commercially available treatment planning software, dose painting for high-grade gliomas was feasible with good BTV coverage and no significant change in the dose to OARs. ADVANCES IN KNOWLEDGE A novel treatment planning strategy was used to achieve dose painting for gliomas with BTVs obtained from 18F-FDOPA PET/CT using a radiobiological model.
Collapse
Affiliation(s)
- Robert Kosztyla
- 1 Department of Medical Physics, BC Cancer - Vancouver , Vancouver, British Columbia , Canada.,2 Department of Physics and Astronomy, University of British Columbia , Vancouver, British Columbia , Canada
| | - Srinivas Raman
- 3 Department of Radiation Oncology, BC Cancer - Vancouver , Vancouver, British Columbia , Canada
| | - Vitali Moiseenko
- 4 Department of Radiation Medicine and Applied Sciences, University of California San Diego , La Jolla, California , US
| | - Stefan A Reinsberg
- 2 Department of Physics and Astronomy, University of British Columbia , Vancouver, British Columbia , Canada
| | - Brian Toyota
- 5 Division of Neurosurgery, University of British Columbia , Vancouver, British Columbia , Canada
| | - Alan Nichol
- 3 Department of Radiation Oncology, BC Cancer - Vancouver , Vancouver, British Columbia , Canada
| |
Collapse
|
19
|
Matuszak MM, Kashani R, Green M, Lee C, Cao Y, Owen D, Jolly S, Mierzwa M. Functional Adaptation in Radiation Therapy. Semin Radiat Oncol 2019; 29:236-244. [PMID: 31027641 DOI: 10.1016/j.semradonc.2019.02.006] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The promise of adaptive therapy to improve outcomes in radiation oncology has been an area of interest and research in the community for many years. One of the sources of data that can be used to drive adaptive therapy is functional information about the tumor or normal tissues. This avenue of adaptation includes many potential sources of data including global markers and functional imaging. Global markers can be assessments derived from blood measurements, patient functional testing, and circulating tumor material and functional imaging data comprises spatial physiological information from various imaging studies such as positron emission tomography, magnetic resonance imaging, and single photon emission computed tomography. The goal of functional adaptation is to use these functional data to adapt radiation therapy to improve patient outcomes. While functional adaptation holds a lot of promise, there are challenges such as quantifying and minimizing uncertainties, streamlining clinical implementation, determining the ideal way to incorporate information within treatment plan optimization, and proving the clinical benefit through trials. This paper will discuss the types of functional information currently being used for adaptation, highlight several areas where functional adaptation has been studied, and introduce some of the barriers to more widespread clinical implementation.
Collapse
Affiliation(s)
- Martha M Matuszak
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI.
| | - Rojano Kashani
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| | - Michael Green
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| | - Choonik Lee
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| | - Yue Cao
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| | - Dawn Owen
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| | - Shruti Jolly
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| | - Michelle Mierzwa
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| |
Collapse
|
20
|
Grönlund E, Johansson S, Nyholm T, Thellenberg C, Ahnesjö A. Dose painting of prostate cancer based on Gleason score correlations with apparent diffusion coefficients. Acta Oncol 2018; 57:574-581. [PMID: 29260950 DOI: 10.1080/0284186x.2017.1415457] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
BACKGROUND Gleason scores for prostate cancer correlates with an increased recurrence risk after radiotherapy (RT). Furthermore, higher Gleason scores correlates with decreasing apparent diffusion coefficient (ADC) data from diffusion weighted MRI (DWI-MRI). Based on these observations, we present a formalism for dose painting prescriptions of prostate volumes based on ADC images mapped to Gleason score driven dose-responses. METHODS The Gleason score driven dose-responses were derived from a learning data set consisting of pre-RT biopsy data and post-RT outcomes for 122 patients treated with a homogeneous dose to the prostate. For a test data set of 18 prostate cancer patients with pre-RT ADC images, we mapped the ADC data to the Gleason driven dose-responses by using probability distributions constructed from published Gleason score correlations with ADC data. We used the Gleason driven dose-responses to optimize dose painting prescriptions that maximize the tumor control probability (TCP) with equal average dose as for the learning sets homogeneous treatment dose. RESULTS The dose painting prescriptions increased the estimated TCP compared to the homogeneous dose by 0-51% for the learning set and by 4-30% for the test set. The potential for individual TCP gains with dose painting correlated with increasing Gleason score spread and larger prostate volumes. The TCP gains were also found to be larger for patients with a low expected TCP for the homogeneous dose prescription. CONCLUSIONS We have from retrospective treatment data demonstrated a formalism that yield ADC driven dose painting prescriptions for prostate volumes that potentially can yield significant TCP increases without increasing dose burdens as compared to a homogeneous treatment dose. This motivates further development of the approach to consider more accurate ADC to Gleason mappings, issues with delivery robustness of heterogeneous dose distributions, and patient selection criteria for design of clinical trials.
Collapse
Affiliation(s)
- Eric Grönlund
- Department of Immunology, Genetics and Pathology, Medical Radiation Sciences, Uppsala University, Uppsala, Sweden
| | - Silvia Johansson
- Department of Immunology, Genetics and Pathology, Experimental and Clinical Oncology, Uppsala University, Uppsala, Sweden
- Uppsala University Hospital, Uppsala, Sweden
| | - Tufve Nyholm
- Department of Radiation Sciences, Umeå University, Umeå, Sweden
| | | | - Anders Ahnesjö
- Department of Immunology, Genetics and Pathology, Medical Radiation Sciences, Uppsala University, Uppsala, Sweden
- Uppsala University Hospital, Uppsala, Sweden
| |
Collapse
|
21
|
Gago-Arias A, Sánchez-Nieto B, Espinoza I, Karger CP, Pardo-Montero J. Impact of different biologically-adapted radiotherapy strategies on tumor control evaluated with a tumor response model. PLoS One 2018; 13:e0196310. [PMID: 29698534 PMCID: PMC5919644 DOI: 10.1371/journal.pone.0196310] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2017] [Accepted: 04/10/2018] [Indexed: 11/26/2022] Open
Abstract
Motivated by the capabilities of modern radiotherapy techniques and by the recent developments of functional imaging techniques, dose painting by numbers (DPBN) was proposed to treat tumors with heterogeneous biological characteristics. This work studies different DPBN optimization techniques for virtual head and neck tumors assessing tumor response in terms of cell survival and tumor control probability with a previously published tumor response model (TRM). Uniform doses of 2 Gy are redistributed according to the microscopic oxygen distribution and the density distribution of tumor cells in four virtual tumors with different biological characteristics. In addition, two different optimization objective functions are investigated, which: i) minimize tumor cell survival (OFsurv) or; ii) maximize the homogeneity of the density of surviving tumor cells (OFstd). Several adaptive schemes, ranging from single to daily dose optimization, are studied and the treatment response is compared to that of the uniform dose. The results show that the benefit of DPBN treatments depends on the tumor reoxygenation capability, which strongly differed among the set of virtual tumors investigated. The difference between daily (fraction by fraction) and three weekly optimizations (at the beginning of weeks 1, 3 and 4) was found to be small, and higher benefit was observed for the treatments optimized using OFsurv. This in silico study corroborates the hypothesis that DPBN may be beneficial for treatments of tumors which show reoxygenation during treatment, and that a few optimizations may be sufficient to achieve this therapeutic benefit.
Collapse
Affiliation(s)
- Araceli Gago-Arias
- Instituto de Física, Pontificia Universidad Católica de Chile, Santiago, Chile
- * E-mail:
| | | | - Ignacio Espinoza
- Instituto de Física, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Christian P. Karger
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
| | - Juan Pardo-Montero
- Grupo de Imaxe Molecular, Instituto de Investigación Sanitaria (IDIS), Santiago de Compostela, Spain
- Servizo de Radiofísica e Protección Radiolóxica, Complexo Hospitalario Universitario de Santiago de Compostela, Santiago de Compostela, Spain
| |
Collapse
|