1
|
Treatment planning comparison between dynamic wave arc and volumetric modulated arc therapies for prostate-cancer treatment. Med Dosim 2021; 47:48-53. [PMID: 34538693 DOI: 10.1016/j.meddos.2021.08.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Revised: 07/05/2021] [Accepted: 08/08/2021] [Indexed: 11/21/2022]
Abstract
The aim of this study was to compare the quality of dynamic wave arc (DWA) and coplanar volumetric modulated arc therapy (co-VMAT) plans for the treatment of localized prostate cancer. The planning target volume (PTV)-rectum, a section of the PTV comprising the PTV minus that of the rectum, received 78 Gy in 39 fractions as the mean dose to the PTV-rectum. The DWA and co-VMAT plans were generated for each patient using the RayStation treatment planning system for the Vero4DRT system. The PTV-rectum dose (D95%: the percent dose irradiating 95% of the volume), homogeneity index (HI), conformity index (CI), as well as doses to the bladder wall, rectum wall (V10-70 Gy: the percent volume receiving 10-70 Gy), and bilateral femoral heads of the DWA and co-VMAT plans were compared. The output monitor unit (MU) and delivery time obtained for each set of plans were also investigated. In terms of target coverage, the DWA plans provided an average D95% of 75.5 Gy, which was comparable to the co-VMAT-plan D95% of 75.2 Gy (p < 0.05). The HI was significantly better with the DWA. As for the DWA plans, the bladder-wall volume receiving 10, 20, 30, and 40 Gy (V10-40 Gy) was significantly smaller than that of the co-VMAT plans, and the volume of the rectal wall receiving 10 Gy (V10Gy) was significantly larger than that of the co-VMAT plans. The DWA plans yielded a reduced dose to the bilateral femoral heads compared with the co-VMAT plans (p < 0.05). The values of the CI and MU, and the delivery time exhibited no significant differences between the DWA and co-VMAT plans. The DWA plan is a feasible treatment option for prostate cancer radiotherapy.
Collapse
|
2
|
Hiraoka M, Mizowaki T, Matsuo Y, Nakamura M, Verellen D. The gimbaled-head radiotherapy system: Rise and downfall of a dedicated system for dynamic tumor tracking with real-time monitoring and dynamic WaveArc. Radiother Oncol 2020; 153:311-318. [PMID: 32659250 DOI: 10.1016/j.radonc.2020.07.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 07/01/2020] [Accepted: 07/02/2020] [Indexed: 10/23/2022]
Abstract
A gimbaled-head radiotherapy device was developed by industry-academic collaborations, with a concept of robust structures whilst maintaining high flexibilities, and its clinical application started in 2008. The unique structures with multi-image guidance functions initiated 2 new treatment modalities. One is dynamic tumor tracking radiotherapy with real time monitoring (DTTRM), which enables 4-D radiotherapy without prolongation of radiotherapy treatment time. This treatment has become clinically feasible for stereotactic body radiotherapy (SBRT) of lung cancers and liver tumors, and intensity-modulated radiotherapy (IMRT) for pancreatic cancers. The second one is Dynamic WaveArc therapy (DWA), the non-coplanar versatility of the SBRT system by combining the gantry-ring synchronized rotation with dynamic multileaf collimator optimization. DWA opens the possibility to create patient-individualized treatment plans, allowing additional flexibility in organ at risk sparing while preserving dosimetric robust delivery. The clinical usefulness of the DWA has been preliminary shown for those tumors in the prostate, breast and skull base. Prospective clinical trials are under way with a support of the national funding of Japan for DTTRM and DWA, respectively. Marketing of the system was terminated in 2016 due to a commercial decision. However, lessons can be learned from the development process of this device that might be useful for those who have interests in new technologies and clinical applications in radiation oncology. This review article aims to summarize the developments and achievements of a gimbaled-head radiotherapy device with a focus on DTTRM and DWA.
Collapse
Affiliation(s)
- Masahiro Hiraoka
- Department of Radiation Oncology, Japanese Red Cross Wakayama Medical Center, Japan.
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Japan
| | - Yukinori Matsuo
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Japan
| | - Mitsuhiro Nakamura
- Division of Medical Physics, Department of Information Technology and Medical Engineering, Human Health Sciences, Graduate School of Medicine, Kyoto University, Japan
| | - Dirk Verellen
- Iridium Kankernetwerk, Antwerp University, Faculty of Medicine and Health Sciences, Belgium
| |
Collapse
|
3
|
Smyth G, Evans PM, Bamber JC, Bedford JL. Recent developments in non-coplanar radiotherapy. Br J Radiol 2019; 92:20180908. [PMID: 30694086 PMCID: PMC6580906 DOI: 10.1259/bjr.20180908] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Revised: 01/15/2019] [Accepted: 01/17/2019] [Indexed: 11/05/2022] Open
Abstract
This paper gives an overview of recent developments in non-coplanar intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Modern linear accelerators are capable of automating motion around multiple axes, allowing efficient delivery of highly non-coplanar radiotherapy techniques. Novel techniques developed for C-arm and non-standard linac geometries, methods of optimization, and clinical applications are reviewed. The additional degrees of freedom are shown to increase the therapeutic ratio, either through dose escalation to the target or dose reduction to functionally important organs at risk, by multiple research groups. Although significant work is still needed to translate these new non-coplanar radiotherapy techniques into the clinic, clinical implementation should be prioritized. Recent developments in non-coplanar radiotherapy demonstrate that it continues to have a place in modern cancer treatment.
Collapse
Affiliation(s)
- Gregory Smyth
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, UK
| | | | - Jeffrey C Bamber
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, UK
| | - James L Bedford
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, UK
| |
Collapse
|
4
|
Hirashima H, Nakamura M, Miyabe Y, Mukumoto N, Ono T, Iramina H, Mizowaki T. Quality assurance of non-coplanar, volumetric-modulated arc therapy employing a C-arm linear accelerator, featuring continuous patient couch rotation. Radiat Oncol 2019; 14:62. [PMID: 30971273 PMCID: PMC6458733 DOI: 10.1186/s13014-019-1264-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2018] [Accepted: 03/27/2019] [Indexed: 12/21/2022] Open
Abstract
PURPOSE To perform quality assurance of non-coplanar, volumetric-modulated arc therapy featuring continuous couch rotation (CCR-VMAT) using a C-arm linear accelerator. METHODS We planned and delivered CCR-VMAT using the TrueBeam Developer Mode. Treatment plans were created for both a C-shaped phantom and five prostate cancer patients using seven CCR trajectories that lacked collisions; we used RayStation software (ver. 4.7) to this end. Subsequently, verification plans were generated. The mean absolute error (MAE) between the center of an MV-imaged steel ball and the radiation field was calculated using the Winston-Lutz test. The MAEs between planned and actual irradiation values were also calculated from trajectory logs. In addition, correlation coefficients (r values) among the MAEs of gantry angle, couch angle, and multi-leaf collimator (MLC) position, and mechanical parameters including gantry speed, couch speed, MLC speed, and beam output, were estimated. The dosimetric accuracies of planned and measured values were also assessed using ArcCHECK. RESULTS The MAEs ±2 standard deviations as revealed by the Winston-Lutz test for all trajectories were 0.3 ± 0.3 mm in two dimensions. The MAEs of the gantry, couch, and MLC positions calculated from all trajectory logs were within 0.04°, 0.08°, and 0.02 mm, respectively. Deviations in the couch angle (r = 0.98, p < 0.05) and MLC position (r = 0.86, p < 0.05) increased significantly with speed. The MAE of the beam output error was less than 0.01 MU. The mean gamma passing rate ± 2 SD (range) of the 3%/3 mm, 3%/1 mm, and 5%/1 mm was 98.1 ± 1.9% (95.7-99.6%), 87.2 ± 2.8% (80.2-96.7%), and 96.3 ± 2.8% (93.9-99.6%), respectively. CONCLUSIONS CCR-VMAT delivered via the TrueBeam Developer Mode was associated with high-level geometric and mechanical accuracy, thus affording to high dosimetric accuracy. The CCR-VMAT performance was stable regardless of the trajectory chosen.
Collapse
Affiliation(s)
- Hideaki Hirashima
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507 Japan
| | - Mitsuhiro Nakamura
- Division of Medical Physics, Department of Information Technology and Medical Engineering, Human Health Sciences, Graduate School of Medicine, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507 Japan
| | - Yuki Miyabe
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507 Japan
| | - Nobutaka Mukumoto
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507 Japan
| | - Tomohiro Ono
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507 Japan
| | - Hiraku Iramina
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507 Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507 Japan
| |
Collapse
|
5
|
Ono Y, Yoshimura M, Hirata K, Ono T, Hirashima H, Mukumoto N, Nakamura M, Inoue M, Hiraoka M, Mizowaki T. Dosimetric advantages afforded by a new irradiation technique, Dynamic WaveArc, used for accelerated partial breast irradiation. Phys Med 2018; 48:103-110. [PMID: 29728221 DOI: 10.1016/j.ejmp.2018.03.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2017] [Revised: 03/13/2018] [Accepted: 03/23/2018] [Indexed: 12/25/2022] Open
Abstract
PURPOSE To identify dosimetric advantages of the novel Dynamic WaveArc (DWA) technique for accelerated partial breast irradiation (APBI), compared with non-coplanar three-dimensional conformal radiotherapy (nc3D-CRT) and coplanar tangential volumetric modulated arc therapy (tVMAT) with dual arcs of 45-65°. METHODS Vero4DRT enables DWA by continuous gantry rotation and O-ring skewing with movement of the multi-leaf collimator. We compared the dose distributions of DWA, nc3D-CRT and tVMAT in 24 consecutive left-sided breast cancer patients treated with APBI (38.5 Gy in 10 fractions). The average doses and volumes to the planning target volume (PTV) and organs at risk, especially heart and left anterior descending artery (LAD) were compared among DWA, nc3D-CRT and tVMAT. RESULTS The doses and volumes to the PTVs did not differ significantly among the three plans. For the DWA plans, the mean dose to the heart was 0.2 ± 0.1 Gy, less than those of the nc3D-CRT and tVMAT plans. The D2% values of the planning organ at risk volume of the LAD were 9.3 ± 10.9%, 28.2 ± 31.9% and 20.3 ± 25.7% for DWA, nc3D-CRT and tVMAT, respectively. The V20Gy and V10Gy of the ipsilateral lung for the DWA plans were also significantly lower. CONCLUSIONS DWA allowed to find a better compromise for OAR which overlapped with the PTV. Use of the DWA for APBI improved the dose distributions compared with those of nc3D-CRT and tVMAT.
Collapse
Affiliation(s)
- Yuka Ono
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| | - Michio Yoshimura
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Kimiko Hirata
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| | - Tomohiro Ono
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| | - Hideaki Hirashima
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| | - Nobutaka Mukumoto
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| | - Mitsuhiro Nakamura
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan; Division of Medical Physics, Department of Information Technology and Medical Engineering, Human Health Sciences, Graduate School of Medicine, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Minoru Inoue
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| | - Masahiro Hiraoka
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| |
Collapse
|
6
|
Hirashima H, Miyabe Y, Nakamura M, Mukumoto N, Mizowaki T, Hiraoka M. Quality assurance of geometric accuracy based on an electronic portal imaging device and log data analysis for Dynamic WaveArc irradiation. J Appl Clin Med Phys 2018; 19:234-242. [PMID: 29633542 PMCID: PMC5978977 DOI: 10.1002/acm2.12324] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 12/28/2017] [Accepted: 03/02/2018] [Indexed: 11/26/2022] Open
Abstract
The purpose of this study was to develop a simple verification method for the routine quality assurance (QA) of Dynamic WaveArc (DWA) irradiation using electronic portal imaging device (EPID) images and log data analysis. First, an automatic calibration method utilizing the outermost multileaf collimator (MLC) slits was developed to correct the misalignment between the center of the EPID and the beam axis. Moreover, to verify the detection accuracy of the MLC position according to the EPID images, various positions of the MLC with intentional errors in the range 0.1–1 mm were assessed. Second, to validate the geometric accuracy during DWA irradiation, tests were designed in consideration of three indices. Test 1 evaluated the accuracy of the MLC position. Test 2 assessed dose output consistency with variable dose rate (160–400 MU/min), gantry speed (2.2–6°/s), and ring speed (0.5–2.7°/s). Test 3 validated dose output consistency with variable values of the above parameters plus MLC speed (1.6–4.2 cm/s). All tests were delivered to the EPID and compared with those obtained using a stationary radiation beam with a 0° gantry angle. Irradiation log data were recorded simultaneously. The 0.1‐mm intentional error on the MLC position could be detected by the EPID, which is smaller than the EPID pixel size. In Test 1, the MLC slit widths agreed within 0.20 mm of their exposed values. The averaged root‐mean‐square error (RMSE) of the dose outputs was less than 0.8% in Test 2 and Test 3. Using log data analysis in Test 3, the RMSE between the planned and recorded data was 0.1 mm, 0.12°, and 0.07° for the MLC position, gantry angle, and ring angle, respectively. The proposed method is useful for routine QA of the accuracy of DWA.
Collapse
Affiliation(s)
- Hideaki Hirashima
- Department of Radiation Oncology and Image-applied therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Yuki Miyabe
- Department of Radiation Oncology and Image-applied therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Mitsuhiro Nakamura
- Department of Radiation Oncology and Image-applied therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Nobutaka Mukumoto
- Department of Radiation Oncology and Image-applied therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-applied therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Masahiro Hiraoka
- Department of Radiation Oncology and Image-applied therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| |
Collapse
|
7
|
Hirashima H, Nakamura M, Miyabe Y, Uto M, Nakamura K, Mizowaki T. Monitoring of mechanical errors and their dosimetric impact throughout the course of non-coplanar continuous volumetric-modulated arc therapy. Radiat Oncol 2018; 13:27. [PMID: 29444693 PMCID: PMC5813375 DOI: 10.1186/s13014-018-0972-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2017] [Accepted: 02/11/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Volumetric-modulated Dynamic WaveArc therapy (VMDWAT) is a non-coplanar continuous volumetric modulated radiation therapy (VMAT) delivery technique. Here, we monitored mechanical errors and their impact on dose distributions in VMDWAT using logfiles throughout the course of treatment. METHODS Fifteen patients were enrolled (2 skull base tumor patients and 13 prostate cancer patients). VMDWAT plans were created for the enrolled patients. The prescribed dose for the skull base tumor was set as 54 Gy at 1.8 Gy per fraction, and that for the prostate cancer was set as 72 to 78 Gy at 2 Gy per fraction. We acquired logfiles to monitor mechanical errors and their impact on dose distribution in each fraction. The root mean square error (RMSE) in the multi-leaf collimator (MLC), gantry angle, O-ring angle and monitor unit (MU) were calculated using logfiles throughout the course of VMDWAT for each patient. The dosimetric impact of mechanical errors throughout the course of VMDWAT was verified using a logfile-based dose reconstruction method. Dosimetric errors between the reconstructed plans and the original plans were assessed. RESULTS A total of 517 datasets, including 55 datasets for the 2 skull base tumor patients and 462 datasets for the 13 prostate cancer patients, were acquired. The RMSE values were less than 0.1 mm, 0.2°, 0.1°, and 0.4 MU for MLC position, gantry angle, O-ring angle, and MU, respectively. For the skull base tumors, the absolute mean dosimetric errors and two standard deviations throughout the course of treatment were less than 1.4% and 1.1%, respectively. For prostate cancer, these absolute values were less than 0.3% and 0.5%, respectively. The largest dosimetric error of 2.5% was observed in a skull base tumor patient. The resultant dosimetric error in the accumulated daily delivered dose distribution, in the patient with the largest error, was up to 1.6% for all dose-volumetric parameters relative to the planned dose distribution. CONCLUSIONS MLC position, gantry rotation, O-ring rotation and MU were highly accurate and stable throughout the course of treatment. The daily dosimetric errors due to mechanical errors were small. VMDWAT provided high delivery accuracy and stability throughout the course of treatment. TRIAL REGISTRATION UMIN000023870 . Registered: 1 October 2016.
Collapse
Affiliation(s)
- Hideaki Hirashima
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Mitsuhiro Nakamura
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan. .,Division of Medical Physics, Department of Information Technology and Medical Engineering, Human Health Sciences, Graduate School of Medicine, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan.
| | - Yuki Miyabe
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Megumi Uto
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Kiyonao Nakamura
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| |
Collapse
|
8
|
Hirashima H, Nakamura M, Miyabe Y, Mukumoto N, Uto M, Nakamura K, Mizowaki T, Hiraoka M. Geometric and dosimetric quality assurance using logfiles and a 3D helical diode detector for Dynamic WaveArc. Phys Med 2017; 43:107-113. [PMID: 29195552 DOI: 10.1016/j.ejmp.2017.10.023] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2017] [Revised: 09/20/2017] [Accepted: 10/26/2017] [Indexed: 12/28/2022] Open
Abstract
PURPOSE To conduct patient-specific geometric and dosimetric quality assurance (QA) for the Dynamic WaveArc (DWA) using logfiles and ArcCHECK (Sun Nuclear Inc., Melbourne, FL, USA). METHODS Twenty DWA plans, 10 for pituitary adenoma and 10 for prostate cancer, were created using RayStation version 4.7 (RaySearch Laboratories, Stockholm, Sweden). Root mean square errors (RMSEs) between the actual and planned values in the logfiles were evaluated. Next, the dose distributions were reconstructed based on the logfiles. The differences between dose-volumetric parameters in the reconstructed plans and those in the original plans were calculated. Finally, dose distributions were assessed using ArcCHECK. In addition, the reconstructed dose distributions were compared with planned ones. RESULTS The means of RMSEs for the gantry, O-ring, MLC position, and MU for all plans were 0.2°, 0.1°, 0.1 mm, and 0.4 MU, respectively. Absolute means of the change in PTV D99% were 0.4 ± 0.4% and 0.1 ± 0.1% points between the original and reconstructed plans for pituitary adenoma and prostate cancer, respectively. The mean of the gamma passing rate (3%/3 mm) between the measured and planned dose distributions was 97.7%. In addition, that between the reconstructed and planned dose distributions was 99.6%. CONCLUSIONS We have demonstrated that the geometric accuracy and gamma passing rates were within AAPM 119 and 142 criteria during DWA. Dose differences in the dose-volumetric parameters using the logfile-based dose reconstruction method were also clinically acceptable in DWA.
Collapse
Affiliation(s)
- Hideaki Hirashima
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| | - Mitsuhiro Nakamura
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan.
| | - Yuki Miyabe
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| | - Nobutaka Mukumoto
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| | - Megumi Uto
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| | - Kiyonao Nakamura
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| | - Masahiro Hiraoka
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| |
Collapse
|
9
|
Giglioli FR, Clemente S, Esposito M, Fiandra C, Marino C, Russo S, Strigari L, Villaggi E, Stasi M, Mancosu P. Frontiers in planning optimization for lung SBRT. Phys Med 2017; 44:163-170. [PMID: 28566240 DOI: 10.1016/j.ejmp.2017.05.064] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2016] [Revised: 05/19/2017] [Accepted: 05/22/2017] [Indexed: 12/25/2022] Open
Abstract
Emerging data are showing the safety and the efficacy of Stereotactic Body Radiation therapy (SBRT) in lung cancer management. In this context, the very high doses delivered to the Planning Target Volume, make the planning phase essential for achieving high dose levels conformed to the shape of the target in order to have a good prognosis for tumor control and to avoid an overdose in relevant healthy adjacent tissue. In this non-systematic review we analyzed the technological and the physics aspects of SBRT planning for lung cancer. In particular, the aims of the study were: (i) to evaluate prescription strategies (homogeneous or inhomogeneous), (ii) to outline possible geometrical solutions by comparing the dosimetric results (iii) to describe the technological possibilities for a safe and effective treatment, (iv) to present the issues concerning radiobiological planning and the automation of the planning process.
Collapse
Affiliation(s)
| | | | | | - Christian Fiandra
- Dep. of Oncology Radiation Oncology Unit, University of Torino, Italy
| | | | | | - Lidia Strigari
- Laboratory of Medical Physics and Expert Systems, Regina Elena National Cancer, Institute IFO, Rome, Italy
| | | | - Michele Stasi
- Medical Physics Dept., Azienda Ospedaliera Ordine Mauriziano di Torino, Torino, Italy
| | - Pietro Mancosu
- Medical Physics Unit of Radiotherapy Dept., Humanitas Clinical and Research Hospital, Rozzano (MI), Italy
| |
Collapse
|