1
|
Karger CP, Elter A, Dorsch S, Mann P, Pappas E, Oldham M. Validation of complex radiotherapy techniques using polymer gel dosimetry. Phys Med Biol 2024; 69:06TR01. [PMID: 38330494 DOI: 10.1088/1361-6560/ad278f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Accepted: 02/08/2024] [Indexed: 02/10/2024]
Abstract
Modern radiotherapy delivers highly conformal dose distributions to irregularly shaped target volumes while sparing the surrounding normal tissue. Due to the complex planning and delivery techniques, dose verification and validation of the whole treatment workflow by end-to-end tests became much more important and polymer gel dosimeters are one of the few possibilities to capture the delivered dose distribution in 3D. The basic principles and formulations of gel dosimetry and its evaluation methods are described and the available studies validating device-specific geometrical parameters as well as the dose delivery by advanced radiotherapy techniques, such as 3D-CRT/IMRT and stereotactic radiosurgery treatments, the treatment of moving targets, online-adaptive magnetic resonance-guided radiotherapy as well as proton and ion beam treatments, are reviewed. The present status and limitations as well as future challenges of polymer gel dosimetry for the validation of complex radiotherapy techniques are discussed.
Collapse
Affiliation(s)
- Christian P Karger
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
| | - Alina Elter
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
- Department of Radiation Oncology, University Hospital Heidelberg, Im Neuenheimer Feld 400, D-69120 Heidelberg, Germany
| | - Stefan Dorsch
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
| | - Philipp Mann
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
| | - Evangelos Pappas
- Radiology & Radiotherapy Sector, Department of Biomedical Sciences, University of West Attica, Athens, Greece
| | - Mark Oldham
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, United States of America
| |
Collapse
|
2
|
Wang L, Guo S, Zhang X. Novel Radiochromic Elastomer Dosimeter Based on the Self-Sensitizing Effect of Disulfide Bonds. ACS APPLIED MATERIALS & INTERFACES 2024; 16:6474-6484. [PMID: 38285620 DOI: 10.1021/acsami.3c17945] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/31/2024]
Abstract
γ-Irradiation is a kind of high-energy ionizing ray, which has widespread applications in material, food, and medical industries as well as in the environment. Since this irradiation is invisible, quantitatively monitoring its exposure doses is crucial to irradiated targets. As a type of dosimeter, radiochromic dosimeters can detect γ-irradiation by color changing, and its strategy to realize the radiochromic behavior basically relies on active radicals from radiolysis of an external environmental medium. However, the primary problem of this external environment-mediated sensitization strategy is that it complicates the components of dosimeters. Herein, we present a novel type of self-sensitizing radiochromic poly(urethane-urea) elastomers (PUUEs), where disulfide bonds, serving as radiation-responsive and sensitizing units, are introduced. This is the first attempt to utilize radicals generated from radiolysis of weak bonds in a solid polymer matrix to sensitize color change of dye-doped radiochromic dosimeters. Moreover, it is intriguing that the simultaneously introduced aryl hydrazone bond endows dosimeters with excellent color retention and maintains the Δa* value of 72.9% even after 1 month on the basis of the as-irradiated specimen. Besides, the metathesis of disulfide bonds not only endows dosimeters with better self-healing capability, but also accelerates the postcuring behavior and hydrogen bond reconfiguration, resulting in improved mechanical performance.
Collapse
Affiliation(s)
- Lei Wang
- The State Key Laboratory of Polymer Materials Engineering, Polymer Research Institute of Sichuan University, Chengdu 610065, China
| | - Shaoyun Guo
- The State Key Laboratory of Polymer Materials Engineering, Polymer Research Institute of Sichuan University, Chengdu 610065, China
| | - Xianlong Zhang
- The State Key Laboratory of Polymer Materials Engineering, Polymer Research Institute of Sichuan University, Chengdu 610065, China
| |
Collapse
|
3
|
Maeyama T, Hayashi K, Watanabe Y, Ohara M, Nakagawa S. Development of a silicone-based radio-fluorogenic dosimeter using dihydrorhodamine 6G. Phys Med 2023; 114:102684. [PMID: 37778206 DOI: 10.1016/j.ejmp.2023.102684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Revised: 07/24/2023] [Accepted: 09/11/2023] [Indexed: 10/03/2023] Open
Abstract
A silicon-based three-dimensional dosimeter can be formed in a free shape without a container and deformed because of its flexibility. Several studies have focused on enhancing its radiological characteristics and assessing its applicability as a quality assurance tool for image-guided and adaptive radiation therapy, considering motion and deformation. Here, we applied a fluorescence probe (dihydrorhodamine 6G, DHR6G) to a silicon elastomer as a new radiosensitive compound that converts nonfluorescent into fluorescent dyes using irradiation, and its fluorescence intensity increases linearly with the absorbed dose. In this study, we demonstrated a cost-effective synthesis method and optimized the composition conditions. The results showed that the DHR6G-SE prepared from 2.2 × 10-3 wt% DHR6G, 0.024 wt% pyridine, and a silicone elastomer (SE) (SILPOT TM 184, base/curing agent = 10/1) exhibited a linear increase in fluorescence with radiation exposure within a dose range of 0-8 Gy and a highly stable sensitivity for as long as 64 h. To demonstrate its container-less characteristics, the possibility of dosimetry for low-energy X-rays using DHR6G-SE was investigated.
Collapse
Affiliation(s)
- Takuya Maeyama
- Department of Chemistry, School of Science, Kitasato University, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa 252-0373, Japan; RIKEN Nishina Center for Accelerator-Based Science, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan.
| | - Kiichiro Hayashi
- Department of Chemistry, School of Science, Kitasato University, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa 252-0373, Japan
| | - Yusuke Watanabe
- School of Allied Health Sciences, Kitasato University, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa 252-0373, Japan
| | - Maki Ohara
- National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba-City, Chiba 263-8555, Japan
| | - Seiko Nakagawa
- Tokyo Metropolitan Industrial Technology Research Institute, 2-4-10 Aomi, Koto-ku, Tokyo 135-0064, Japan
| |
Collapse
|
4
|
Investigation of Colored Film Indicators for the Assessment of the Occasional Radiation Exposure. Gels 2023; 9:gels9030189. [PMID: 36975638 PMCID: PMC10048619 DOI: 10.3390/gels9030189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 02/26/2023] [Accepted: 02/27/2023] [Indexed: 03/05/2023] Open
Abstract
Occupational radiation exposure monitoring is well-established in clinical or industrial environments with various different dosimeter systems. Despite the availability of many dosimetry methods and devices, a challenge with the occasional exposure registration, which may occur due to the spilling of radioactive materials or splitting of these materials in the environment, still exists, because not every individual will have an appropriate dosimeter at the time of the irradiation event. The aim of this work was to develop radiation-sensitive films—color-changing radiation indicators, which can be attached to or integrated in the textile. Polyvinyl alcohol (PVA)-based polymer hydrogels were used as a basis for fabrication of radiation indicator films. Several organic dyes (brilliant carmosine (BC), brilliant scarlet (BS), methylene red (MR), brilliant green (BG), brilliant blue (BB), methylene blue (MB) and xylenol orange (XiO)) were used as a coloring additives. Moreover, PVA films enriched with Ag nanoparticles (PVA-Ag) were investigated. In order to assess the radiation sensitivity of the produced films, experimental samples were irradiated in a linear accelerator with 6 MeV X-ray photons and the radiation sensitivity of irradiated films was evaluated using UV–Vis spectrophotometry method. The most sensitive were PVA-BB films indicating 0.4 Gy−1 sensitivity in low-dose (0–1 or 2 Gy) range. The sensitivity at higher doses was modest. These PVA-dye films were sensitive enough to detect doses up to 10 Gy and PVA-MR film indicated stable 33.3% decolorization after irradiation at this dose. It was found that the dose sensitivity of all PVA-Ag gel films varied from 0.068 to 0.11 Gy−1 and was dependent on the Ag additives concentration. Exchange of a small amount of water with ethanol or isopropanol caused the enhancement of radiation sensitivity in the films with the lowest AgNO3 concentration. Radiation-induced color change of AgPVA films varied between 30 and 40%. Performed research demonstrated the potential of colored hydrogel films in their applications as indicators for the assessment of the occasional radiation exposure.
Collapse
|
5
|
Maras P, Kozicki M. Fast Isocenter Determination Using 3D Polymer Gel Dosimetry with Kilovoltage Cone-Beam CT Reading and the PolyGeVero-CT Software Package for Linac Quality Assurance in Radiotherapy. MATERIALS (BASEL, SWITZERLAND) 2022; 15:6807. [PMID: 36234149 PMCID: PMC9573670 DOI: 10.3390/ma15196807] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 09/23/2022] [Accepted: 09/25/2022] [Indexed: 06/16/2023]
Abstract
This work presents an approach to the fast determination of a medical accelerator irradiation isocenter as a quality assurance (QA) procedure in radiotherapy. The isocenter determination tool is the tissue equivalent high-resolution 3D polymer gel dosimeter (PABIGnx) in a dedicated container combined with kilovoltage imaging systems and the polyGeVero-CT software package (v. 1.2, GeVero Co., Poland). Two accelerators were employed: Halcyon and TrueBeam (Varian, USA), both equipped with cone beam computed tomography (CBCT) and iterative reconstruction CBCT (iCBCT) algorithms. The scope of this work includes: (i) the examination of factors influencing image quality (reconstruction algorithms and modes), radiation field parameters (dose and multi-leaf collimator (MLC) gaps), fiducial markers, signal averaging for reconstruction algorithms and the scanning time interval between consecutive scans, (ii) the examination of factors influencing the isocenter determination, image processing (signal averaging, background subtraction, image filtering) and (iii) an isocenter determination report using a 2D and 3D approach. An optimized protocol and isocenter determination conditions were found. The time and effort required to determine the isocenter are discussed.
Collapse
Affiliation(s)
- Piotr Maras
- Department of Radiotherapy Planning, Copernicus Hospital, 93-513 Lodz, Poland
- GeVero Co., Tansmana 2/11, 92-548 Lodz, Poland
| | - Marek Kozicki
- GeVero Co., Tansmana 2/11, 92-548 Lodz, Poland
- Department of Mechanical Engineering, Informatics and Chemistry of Polymer Materials, Faculty of Materials Technologies and Textile Design, Lodz University of Technology, 90-543 Lodz, Poland
| |
Collapse
|
6
|
Mohyedin MZ, Zin HM, Adenan MZ, Abdul Rahman AT. A Review of PRESAGE Radiochromic Polymer and the Compositions for Application in Radiotherapy Dosimetry. Polymers (Basel) 2022; 14:2887. [PMID: 35890665 PMCID: PMC9320230 DOI: 10.3390/polym14142887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 07/02/2022] [Accepted: 07/06/2022] [Indexed: 02/01/2023] Open
Abstract
Recent advances in radiotherapy technology and techniques have allowed a highly conformal radiation to be delivered to the tumour target inside the body for cancer treatment. A three-dimensional (3D) dosimetry system is required to verify the accuracy of the complex treatment delivery. A 3D dosimeter based on the radiochromic response of a polymer towards ionising radiation has been introduced as the PRESAGE dosimeter. The polyurethane dosimeter matrix is combined with a leuco-dye and a free radical initiator, whose colour changes in proportion to the radiation dose. In the previous decade, PRESAGE gained improvement and enhancement as a 3D dosimeter. Notably, PRESAGE overcomes the limitations of its predecessors, the Fricke gel and the polymer gel dosimeters, which are challenging to fabricate and read out, sensitive to oxygen, and sensitive to diffusion. This article aims to review the characteristics of the radiochromic dosimeter and its clinical applications. The formulation of PRESAGE shows a delicate balance between the number of radical initiators, metal compounds, and catalysts to achieve stability, optimal sensitivity, and water equivalency. The applications of PRESAGE in advanced radiotherapy treatment verifications are also discussed.
Collapse
Affiliation(s)
- Muhammad Zamir Mohyedin
- School of Physics and Material Studies, Faculty of Applied Sciences, Universiti Teknologi MARA, Shah Alam 40450, Selangor, Malaysia;
- Centre of Astrophysics & Applied Radiation, Institute of Science, Universiti Teknologi MARA, Shah Alam 40450, Selangor, Malaysia
| | - Hafiz Mohd Zin
- Advanced Medical & Dental Institute, Universiti Sains Malaysia, Bertam, Kepala Batas 13700, Penang, Malaysia;
| | - Mohd Zulfadli Adenan
- Centre of Medical Imaging, Faculty of Health Sciences, Universiti Teknologi MARA, Cawangan Selangor Campus of Puncak Alam, Puncak Alam 42300, Selangor, Malaysia;
| | - Ahmad Taufek Abdul Rahman
- School of Physics and Material Studies, Faculty of Applied Sciences, Universiti Teknologi MARA, Shah Alam 40450, Selangor, Malaysia;
- Centre of Astrophysics & Applied Radiation, Institute of Science, Universiti Teknologi MARA, Shah Alam 40450, Selangor, Malaysia
| |
Collapse
|
7
|
Features of PABIG nx 3D Polymer Gel as an Ionising Radiation Dosimeter. MATERIALS 2022; 15:ma15072550. [PMID: 35407883 PMCID: PMC8999682 DOI: 10.3390/ma15072550] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 03/28/2022] [Accepted: 03/29/2022] [Indexed: 01/27/2023]
Abstract
This work presents the features of the PABIGnx 3D polymer gel dosimeter. It consists of two cross-linkers: poly(ethylene glycol) diacrylate (PEGDA), as one biacrylic component, and N,N′-methylenebisacrylamide (MBA), which is another cross-linker often used in 3D dosimeters. Additionally, it contains oxygen scavenges of copper sulfate pentahydrate and ascorbic acid. All ingredients are embedded in a physical gel matrix of gelatine. Upon irradiation, the biacrylic cross-linking agents (PEGDA and MBA) undergo radical polymerisation and cross-linking, which is manifested by the appearance of the opacity of the intensity related to the absorbed dose. PABIGnx was irradiated with an oncological source of ionising radiation, and analysed by using a nuclear magnetic resonance (0.5 T). The following characteristics were obtained: (i) linear and dynamic dose-response of 0.5 to ~18 Gy and 40 Gy, respectively, (ii) dose sensitivity of 0.071 ± 0.001 Gy−1 s−1, (iii) integral 3D dose distribution for at least 24 days after irradiation, (iv) adequate batch-to-batch reproducibility, (v) dose-response independent of irradiation with 6 MV photons, 15 MV photons, 6 MV photons FFF of 0.0168–0.1094 Gy/s dose rates, and (vi) soft tissue equivalence. The study showed that the features of PABIGnx confirm its suitability for use in 3D radiotherapy dosimetry.
Collapse
|
8
|
Maras P, Jaszczak M, Kozicki M. Basic features of VIC-T dosimeter with spiral CT readout, CT scanning conditions and data processing with a new polyGeVero-CT software package. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109730] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
9
|
Soliman YS, Abdel-Fattah AA, Dutremez SG. 1,10-Bis(diphenylamino)-4,6-decadiyne as an active component of a radiochromic film dosimeter. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109714] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
10
|
Gagliardi FM, Franich RD, Geso M. Nanoparticle dose enhancement of synchrotron radiation in PRESAGE dosimeters. JOURNAL OF SYNCHROTRON RADIATION 2020; 27:1590-1600. [PMID: 33147183 DOI: 10.1107/s1600577520012849] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 09/21/2020] [Indexed: 06/11/2023]
Abstract
The physical absorbed dose enhancement by the inclusion of gold and bismuth nanoparticles fabricated into water-equivalent PRESAGE dosimeters was investigated. Nanoparticle-loaded water-equivalent PRESAGE dosimeters were irradiated with superficial, synchrotron and megavoltage X-ray beams. The change in optical density of the dosimeters was measured using UV-Vis spectrophotometry pre- and post-irradiation using a wavelength of 630 nm. Dose enhancement was measured for 5 nm and 50 nm monodispersed gold nanoparticles, 5-50 nm polydispersed bismuth nanoparticles, and 80 nm monodispersed bismuth nanoparticles at concentrations from 0.25 mM to 2 mM. The dose enhancement was highest for the 95.3 keV mean energy synchrotron beam (16-32%) followed by the 150 kVp superficial beam (12-21%) then the 6 MV beam (2-5%). The bismuth nanoparticle-loaded dosimeters produced a larger dose enhancement than the gold nanoparticle-loaded dosimeters in the synchrotron beam for the same concentration. For the superficial and megavoltage beams the dose enhancement was similar for both species of nanoparticles. The dose enhancement increased with nanoparticle concentration in the dosimeters; however, there was no observed nanoparticle size dependence on the dose enhancement.
Collapse
Affiliation(s)
- Frank M Gagliardi
- Alfred Health Radiation Oncology, The Alfred, Commercial Road, Melbourne, Victoria 3004, Australia
| | - Rick D Franich
- School of Science, RMIT University, La Trobe Street, Melbourne, Victoria 3000, Australia
| | - Moshi Geso
- School of Health and Biomedical Sciences, RMIT University, Plenty Road, Bundoora, Victoria 3083, Australia
| |
Collapse
|
11
|
Pergascript orange-based polymeric solution as a dosimeter for radiotherapy dosimetric validation. Phys Med 2019; 57:169-176. [DOI: 10.1016/j.ejmp.2019.01.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Revised: 12/31/2018] [Accepted: 01/04/2019] [Indexed: 10/27/2022] Open
|
12
|
Kwiatos K, Maras P, Kadlubowski S, Stempień Z, Dudek M, Kozicki M. Tetrazolium salts-Pluronic F-127 gels for 3D radiotherapy dosimetry. ACTA ACUST UNITED AC 2018; 63:095012. [DOI: 10.1088/1361-6560/aabbb6] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
13
|
Kozicki M, Kwiatos K, Dudek M, Stempien' Z. Radiochromic gels for UV radiation measurements in 3D. J Photochem Photobiol A Chem 2018. [DOI: 10.1016/j.jphotochem.2017.10.025] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
14
|
Khezerloo D, Nedaie HA, Takavar A, Zirak A, Farhood B, Movahedinejhad H, Banaee N, Ahmadalidokht I, Knuap C. PRESAGE® as a solid 3-D radiation dosimeter: A review article. Radiat Phys Chem Oxf Engl 1993 2017. [DOI: 10.1016/j.radphyschem.2017.06.002] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
15
|
Adamovics JA. Detection of therapeutic radiation in three-dimensions. Beilstein J Org Chem 2017; 13:1325-1331. [PMID: 28781698 PMCID: PMC5530604 DOI: 10.3762/bjoc.13.129] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2017] [Accepted: 06/14/2017] [Indexed: 12/31/2022] Open
Abstract
For over the last twenty years there has been a multitude of sophisticated three-dimensional radiation delivery procedures developed which requires a corresponding verification of the impact on patients. This article reviews the state of the art in the development of chemical detectors used to characterize the three-dimensional shape of therapeutic radiation. These detectors are composed of polyurethane, radical initiator and a leuco dye, which is radiolytically oxidized to a dye absorbing at 630 nm.
Collapse
Affiliation(s)
- John A Adamovics
- Department of Chemistry, Biochemistry and Physics, Rider University, 2083 Lawrenceville Road, Lawrenceville, NJ 08648-3099, USA
| |
Collapse
|
16
|
Dosimetric characteristics of a reusable 3D radiochromic dosimetry material. PLoS One 2017; 12:e0180970. [PMID: 28704443 PMCID: PMC5509250 DOI: 10.1371/journal.pone.0180970] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2016] [Accepted: 06/24/2017] [Indexed: 11/19/2022] Open
Abstract
PURPOSE To investigate the dosimetric characteristics of PRESAGEREU dosimeters. METHODS Commercially available PRESAGEREU dosimeters (size of 10 mm × 10 mm × 45 mm) were divided into two groups, with one of the groups placed at room temperature of 22°C (RT group) and another group placed at low temperature of 10°C (LT group). A total of 3 dosimeters (set of dosimeters) were irradiated at a time, with doses of 1 Gy, 2 Gy, 4 Gy, 8 Gy, 12 Gy, 16 Gy, and 20 Gy, at a nominal dose rate of 400 MU/min at temperature of 22°C. The dosimeters were irradiated three additional times by delivering the same doses as those during the initial irradiations (4 irradiation cycles). Optical density (OD) was assessed using optical CT scanning. RESULTS Considering both linearity and sensitivity of the OD curves, R2 above 0.95 and sensitivity above 0.04 ΔOD/Gy were observed at the 1st irradiation (reading time ≤ 6 h) and 2nd irradiation (reading time = 0.5 h) for the RT group. For the LT group, those values were observed at the 1st irradiation (reading time ≤ 2 h), and the 3rd and 4th irradiations (both reading times = 0.5 h). Considering the reproducibility of signals in response to the same dose, dosimeters in the RT group showed average deviations among dosimeters less than 5% (the 1st and 2nd irradiations at the reading time of 0.5 h), while for dosimeters in the LT group showed average deviations among dosimeters less than 6% (the 3rd and 4th irradiations at the reading time of 0.5 h). For the rest, the OD curves were not linear, sensitivities of the dosimeters were lower than 0.04 ΔOD/Gy, and OD deviations at the same dose were larger than 6%. CONCLUSIONS At room temperature, PRESAGEREU dosimeters could be used for dose measurement only for up to two dose measurement sessions. At low temperatures, usage of PRESAGEREU dosimeters for dose measurement seems to be possible from the 3rd irradiation. When reusing PRESAGEREU dosimeters, the OD curve should be re-defined for every measurement session because the shape of this curve depends on the irradiation history.
Collapse
|
17
|
Kozicki M, Kwiatos K, Kadlubowski S, Dudek M. TTC-Pluronic 3D radiochromic gel dosimetry of ionizing radiation. ACTA ACUST UNITED AC 2017; 62:5668-5690. [DOI: 10.1088/1361-6560/aa77eb] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
18
|
Kozicki M, Jaszczak M, Maras P, Dudek M, Cłapa M. On the development of a VIPARndradiotherapy 3D polymer gel dosimeter. Phys Med Biol 2017; 62:986-1008. [DOI: 10.1088/1361-6560/aa5089] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
19
|
Alqathami M, Blencowe A, Ibbott G. Experimental determination of the influence of oxygen on the PRESAGE®dosimeter. Phys Med Biol 2016; 61:813-24. [DOI: 10.1088/0031-9155/61/2/813] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
20
|
Characterization of novel water-equivalent PRESAGE® dosimeters for megavoltage and kilovoltage x-ray beam dosimetry. RADIAT MEAS 2015. [DOI: 10.1016/j.radmeas.2015.02.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|