1
|
D'Oca MC, Collura G, Gagliardo C, Bartolotta A, Romeo M, d'Errico F, Marrale M. Improvement of neutron sensitivity for lithium formate EPR dosemeters: a Monte Carlo analysis. RADIATION PROTECTION DOSIMETRY 2023; 199:1591-1599. [PMID: 37721086 DOI: 10.1093/rpd/ncac268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Revised: 11/14/2022] [Accepted: 11/19/2022] [Indexed: 09/19/2023]
Abstract
This work presents the computational analysis of the sensitivity improvements that could be achieved in lithium formate monohydrate (LFM) electron paramagnetic resonance (EPR) dosemeters exposed to neutron beams. Monte Carlo (MC) simulations were performed on LFM pellets exposed to neutron beams with different energy spectra at various depths inside a water phantom. Various computations were carried out by considering different enrichments of 6Li inside the LFM matrix as well as addition of different amounts of gadolinium oxide inside the pellet blend. The energy released per unit mass was calculated with the aim of predicting the increase in dose achievable by the addition of sensitizers inside the pellets. As expected, a larger amount of 6Li induces an increase of energy released because of the charged secondary particles (i.e. 3H ions and α-particles) produced after neutron capture. For small depths in water phantom and low-energy neutron spectra the dose increase due to 6Li enrichment is high (more than three orders of magnitude with respect to the case of with 7Li). In case of epithermal neutron beams the energy released in 6Li-enriched LFM compound is smaller but larger than in the case of fast neutron beams. On the other hand, the computational analysis evidenced that gadolinium is less effective than 6Li in improving neutron sensitivity of the LFM pellets. Discussion based on the features of MC transport code is provided. This result suggests that 6Li enrichment of LFM dosemeters would be more effective for neutron sensitivity improvement and these EPR dosemeters could be tested for dosimetric applications in Neutron Capture Therapy.
Collapse
Affiliation(s)
- Maria Cristina D'Oca
- Department of Physics and Chemistry 'Emilio Segrè', University of Palermo, Viale delle Scienze, Ed.18, I-90128 Palermo, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Catania Division, Via Santa Sofia, 64, 95123 Catania, Italy
| | - Giorgio Collura
- Department of Physics and Chemistry 'Emilio Segrè', University of Palermo, Viale delle Scienze, Ed.18, I-90128 Palermo, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Catania Division, Via Santa Sofia, 64, 95123 Catania, Italy
| | - Cesare Gagliardo
- Biomedicine, Neuroscience and Advanced Diagnostics, University of Palermo, 90127, Palermo, Italy
| | - Antonio Bartolotta
- Department of Physics and Chemistry 'Emilio Segrè', University of Palermo, Viale delle Scienze, Ed.18, I-90128 Palermo, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Catania Division, Via Santa Sofia, 64, 95123 Catania, Italy
| | - Mattia Romeo
- Department of Physics and Chemistry 'Emilio Segrè', University of Palermo, Viale delle Scienze, Ed.18, I-90128 Palermo, Italy
| | - Francesco d'Errico
- Dipartimento di Ingegneria Civile e Industriale, Università di Pisa, Largo Lucio Lazzarino, 2 56126 Pisa, Italy
- Magnetic Resonance Research Center, School of Medicine of Yale, 300 Cedar Street, PO Box 208043, New Haven, CT 06520-8043, USA
| | - Maurizio Marrale
- Department of Physics and Chemistry 'Emilio Segrè', University of Palermo, Viale delle Scienze, Ed.18, I-90128 Palermo, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Catania Division, Via Santa Sofia, 64, 95123 Catania, Italy
- ATeN Center, University of Palermo, Viale delle Scienze, Edificio 18, 90128 Palermo, Italy
| |
Collapse
|
3
|
Application of Amino Acids for High-Dosage Measurements with Electron Paramagnetic Resonance Spectroscopy. Molecules 2023; 28:molecules28041745. [PMID: 36838733 PMCID: PMC9958855 DOI: 10.3390/molecules28041745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 02/07/2023] [Accepted: 02/10/2023] [Indexed: 02/16/2023] Open
Abstract
A comparative investigation of amino acids (proline, cysteine, and alanine) as dosimetric materials using electron paramagnetic resonance (EPR) spectroscopy in the absorbed dosage range of 1-25 kGy is presented. There were no signals in the EPR spectra of the samples before irradiation. After irradiation, the complex spectra were recorded. These results showed that the investigated amino acids were sensitive to radiation. In the EPR spectrum of cysteine after irradiation, RS• radicals dominated. The effects of the microwave power on the saturation of the EPR signals showed the presence of at least three different types of free radicals in proline. It was also found out that the DL-proline and cysteine had stable free radicals after irradiation and represented a linear dosage response up to 10 kGy. On the other hand, the amino acid alanine has been accepted by the International Atomic Energy Agency as a transfer standard dosimetry system. In view of this, the obtained results of the proline and cysteine studies have been compared with those of the alanine studies. The results showed that the amino acids proline and cysteine could be used as alternative dosimetric materials in lieu of alanine in a dosage range of 1-10 kGy of an absorbed dose of γ-rays using EPR spectroscopy. Regarding the radiation sensitivity, the following order of decreased dosage responses was determined: alanine > DL-proline > cysteine > L-proline.
Collapse
|
4
|
Dotta TC, Hayann L, de Padua Andrade Almeida L, Nogueira LFB, Arnez MM, Castelo R, Cassiano AFB, Faria G, Martelli-Tosi M, Bottini M, Ciancaglini P, Catirse ABCEB, Ramos AP. Strontium Carbonate and Strontium-Substituted Calcium Carbonate Nanoparticles Form Protective Deposits on Dentin Surface and Enhance Human Dental Pulp Stem Cells Mineralization. J Funct Biomater 2022; 13:jfb13040250. [PMID: 36412891 PMCID: PMC9680411 DOI: 10.3390/jfb13040250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 11/09/2022] [Accepted: 11/14/2022] [Indexed: 11/19/2022] Open
Abstract
Strontium acetate is applied for dental hypersensitivity treatment; however, the use of strontium carbonates for this purpose has not been described. The use of Sr-carbonate nanoparticles takes advantage of both the benefits of strontium on dentin mineralization and the abrasive properties of carbonates. Here in, we aimed to synthesize strontium carbonate and strontium-substituted calcium carbonate nanoparticles and test them as potential compounds in active dentifrices for treating dental hypersensitivity. For this, SrCO3, Sr0.5Ca0.5CO3, and CaCO3 nanoparticles were precipitated using Na2CO3, SrCl2, and/or CaCl2 as precursors. Their morphology and crystallinity were evaluated by electron microscopy (SEM) and X-ray diffraction, respectively. The nanoparticles were added to a poly (vinyl alcohol) gel and used to brush dentin surfaces isolated from human third molars. Dentin chemical composition before and after brushing was investigated by infrared spectroscopy (FTIR) and X-ray dispersive energy spectroscopy. Dentin tubule morphology, obliteration, and resistance of the coatings to acid attack were investigated by SEM and EDS. The cytotoxicity and ability of the particles to trigger the mineralization of hDPSCs in vitro were studied. Dentin brushed with the nanoparticles was coated by a mineral layer that was also able to penetrate the tubules, while CaCO3 remained as individual particles on the surface. FTIR bands related to carbonate groups were intensified after brushing with either SrCO3 or Sr0.5Ca0.5CO3. The shift of the phosphate-related FTIR band to a lower wavenumber indicated that strontium replaced calcium on the dentin structure after treatment. The coating promoted by SrCO3 or Sr0.5Ca0.5CO3 resisted the acid attack, while calcium and phosphorus were removed from the top of the dentin surface. The nanoparticles were not toxic to hDPSCs and elicited mineralization of the cells, as revealed by increased mineral nodule formation and enhanced expression of COL1, ALP, and RUNX2. Adding Sr0.5Ca0.5CO3 as an active ingredient in dentifrices formulations may be commercially advantageous since this compound combines the well-known abrasive properties of calcium carbonate with the mineralization ability of strontium, while the final cost remains between the cost of CaCO3 and SrCO3. The novel Sr0.5Ca0.5CO3 nanoparticles might emerge as an alternative for the treatment of dental hypersensitivity.
Collapse
Affiliation(s)
- Tatiane Cristina Dotta
- Department of Dental Materials and Prosthodontics, Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto 14040-904, Brazil
| | - Larwsk Hayann
- Department of Chemistry, Ribeirão Preto Faculty of Philosophy, Sciences and Letters at Ribeirão Preto, University of São Paulo, Ribeirão Preto 14040-901, Brazil
| | - Leonardo de Padua Andrade Almeida
- Department of Dental Materials and Prosthodontics, Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto 14040-904, Brazil
| | - Lucas Fabrício B. Nogueira
- Department of Chemistry, Ribeirão Preto Faculty of Philosophy, Sciences and Letters at Ribeirão Preto, University of São Paulo, Ribeirão Preto 14040-901, Brazil
| | - Mayara M. Arnez
- Department of Dental Materials and Prosthodontics, Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto 14040-904, Brazil
| | - Raisa Castelo
- Department of Dental Materials and Prosthodontics, Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto 14040-904, Brazil
| | - Ana Flávia B. Cassiano
- Department of Restorative Dentistry, School of Dentistry at Araraquara, Sao Paulo State University (UNESP), Araraquara 14801-385, Brazil
| | - Gisele Faria
- Department of Restorative Dentistry, School of Dentistry at Araraquara, Sao Paulo State University (UNESP), Araraquara 14801-385, Brazil
| | - Milena Martelli-Tosi
- Department of Chemistry, Ribeirão Preto Faculty of Philosophy, Sciences and Letters at Ribeirão Preto, University of São Paulo, Ribeirão Preto 14040-901, Brazil
- Department of Food Engineering, Faculty of Animal Science and Food Engineering, University of São Paulo, Pirassununga 13645-900, Brazil
| | - Massimo Bottini
- Department of Experimental Medicine, University of Rome Tor Vergata, 00133 Rome, Italy
| | - Pietro Ciancaglini
- Department of Chemistry, Ribeirão Preto Faculty of Philosophy, Sciences and Letters at Ribeirão Preto, University of São Paulo, Ribeirão Preto 14040-901, Brazil
| | - Alma B. C. E. B. Catirse
- Department of Dental Materials and Prosthodontics, Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto 14040-904, Brazil
| | - Ana Paula Ramos
- Department of Chemistry, Ribeirão Preto Faculty of Philosophy, Sciences and Letters at Ribeirão Preto, University of São Paulo, Ribeirão Preto 14040-901, Brazil
- Correspondence:
| |
Collapse
|
6
|
Beshir WB, Soliman YS, Abdel-Fattah AA, Fahim RA. A new EPR dosimeter based on glutamic acid for radiation processing application. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2019; 58:501-511. [PMID: 31286207 DOI: 10.1007/s00411-019-00808-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/07/2019] [Accepted: 07/02/2019] [Indexed: 06/09/2023]
Abstract
L-Glutamic acid (L-GA) pellets (3.8 mm × 4 mm) and powder dosimeters were studied in the dose range of 0.1-150 kGy using the electron paramagnetic resonance (EPR) technique. The EPR spectra of irradiated L-GA pellets showed an EPR signal with eight lines, and the intensity of the signal increased with an increase of absorbed dose. The results obtained in terms of the energy-absorption coefficients suggest a similar performance of the L-GA pellets as compared to alanine pellets. The value of the temperature coefficient for the L-GA pellets during irradiation was around - 0.08%/°C which is lower than that reported for alanine dosimeter, 0.14%/°C. The influence of humidity on the pellet response was found to be negligible; i.e., the increase in response was only about 2% for a relative humidity of up to 94%. The response of L-GA powder reached stability 4 h after irradiation and continued to be stable until 47 days after irradiation. In contrast, the response of the L-GA pellet dosimeter reached stability 22 h after irradiation and continued to be stable until 8 days after irradiation. For routine applications, the L-GA pellet dosimeter should be analyzed during the stable period after irradiation, to minimize the uncertainties in dose assessment. The overall two-sigma uncertainties in absorbed dose estimation were 5.1% and 3.9% for the dose ranges of 0.1-15 kGy and 15-150 kGy, respectively. It is concluded that L-GA pellets represent a promising dosimeter material for quantification of radiation doses in food irradiation, medical sterilization and polymer modification.
Collapse
Affiliation(s)
- W B Beshir
- National Center for Radiation Research and Technology, Atomic Energy Authority, Nasr City, P.O. Box 8029, Cairo, Egypt
| | - Yasser S Soliman
- National Center for Radiation Research and Technology, Atomic Energy Authority, Nasr City, P.O. Box 8029, Cairo, Egypt.
| | - A A Abdel-Fattah
- National Center for Radiation Research and Technology, Atomic Energy Authority, Nasr City, P.O. Box 8029, Cairo, Egypt
| | - Ramy Amer Fahim
- National Center for Radiation Research and Technology, Atomic Energy Authority, Nasr City, P.O. Box 8029, Cairo, Egypt
| |
Collapse
|
7
|
Sayed M, Tabassum S, Shah NS, Khan JA, Shah LA, Rehman F, Khan SU, Khan HM, Ullah M. Acid fuchsin dosimeter: a potential dosimeter for food irradiation dosimetry. JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION 2018. [DOI: 10.1007/s11694-018-9983-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|