1
|
Almohammed HI, Elshami W, Hamd ZY, Abuzaid M. Optimizing CT Abdomen-Pelvis Scan Radiation Dose: Examining the Role of Body Metrics (Waist Circumference, Hip Circumference, Abdominal Fat, and Body Mass Index) in Dose Efficiency. Tomography 2024; 10:643-653. [PMID: 38787009 PMCID: PMC11126040 DOI: 10.3390/tomography10050049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2024] [Revised: 04/16/2024] [Accepted: 04/19/2024] [Indexed: 05/25/2024] Open
Abstract
Objective: This study investigates the correlation between patient body metrics and radiation dose in abdominopelvic CT scans, aiming to identify significant predictors of radiation exposure. Methods: Employing a cross-sectional analysis of patient data, including BMI, abdominal fat, waist, abdomen, and hip circumference, we analyzed their relationship with the following dose metrics: the CTDIvol, DLP, and SSDE. Results: Results from the analysis of various body measurements revealed that BMI, abdominal fat, and waist circumference are strongly correlated with increased radiation doses. Notably, the SSDE, as a more patient-centric dose metric, showed significant positive correlations, especially with waist circumference, suggesting its potential as a key predictor for optimizing radiation doses. Conclusions: The findings suggest that incorporating patient-specific body metrics into CT dosimetry could enhance personalized care and radiation safety. Conclusively, this study highlights the necessity for tailored imaging protocols based on individual body metrics to optimize radiation exposure, encouraging further research into predictive models and the integration of these metrics into clinical practice for improved patient management.
Collapse
Affiliation(s)
- Huda I. Almohammed
- Department of Radiological Sciences, College of Health and Rehabilitation Sciences, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia
| | - Wiam Elshami
- Medical Diagnostic Imaging Department, College of Health Sciences, University of Sharjah, Sharjah P.O Box 27272, United Arab Emirates
- Research Institute for Medical and Health Sciences, University of Sharjah, Sharjah P.O Box 27272, United Arab Emirates
| | - Zuhal Y. Hamd
- Department of Radiological Sciences, College of Health and Rehabilitation Sciences, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia
| | - Mohamed Abuzaid
- Medical Diagnostic Imaging Department, College of Health Sciences, University of Sharjah, Sharjah P.O Box 27272, United Arab Emirates
- Research Institute for Medical and Health Sciences, University of Sharjah, Sharjah P.O Box 27272, United Arab Emirates
| |
Collapse
|
2
|
Sulieman A, Mahgoub O, Salah H, Tamam N, Taha A, Dawood S, Bradley DA. Assessment of patient and occupational exposure and radiation risk from cath-lab procedure. Appl Radiat Isot 2023; 202:111071. [PMID: 37871398 DOI: 10.1016/j.apradiso.2023.111071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 09/22/2023] [Accepted: 10/12/2023] [Indexed: 10/25/2023]
Abstract
Due to the extended localized fluoroscopy, many radiographic exposures, and multiple procedures that might result in tissue reaction, patients and personnel received a significant radiation dose during interventional cardiology (IR) procedures. This study aims to calculate the radiation risk and assess patient and staff effective doses during IC procedures. Thirty-two patients underwent a Cath lab treatment in total. Ten Cath lab personnel, including six nurses, two cardiologists, and two X-ray technologists. Optical stimulating-luminescent dosimeters (OSL) (Al2O3:C) calibrated for this purpose were used to monitor both occupational and ambient doses. Using an automated OSL reader, these badges were scanned. The Air Kerma (mGy) and Kerma Area Products (KAP, mGy.cm2) have a mean and standard deviation (SD) of 371 ± 132 and 26052, respectively. The average personal dose equivalent (mSv) and its range for cardiologists, nurses and X ray technologists were 1.11 ± 0.21 (0.96-1.26), 0.84 ± 0.11 (0.68-1.16), and 0.68 ± 0.014 (0.12-0.13), respectively. The current study findings showed that the annual effective dose for cardiologists, nurses, and X-ray technologists was lesser than the yearly occupational dose limit of 20 mSv recommended by national and international guidelines. The patients' doses are comparable with some previously published studies and below the tissue reaction limits.
Collapse
Affiliation(s)
- Abdelmoneim Sulieman
- Prince Sattam Bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, Alkharj, Saudi Arabia.
| | - Omer Mahgoub
- College of Medical Radiologic Science, Sudan University of Science and Technology, Khartoum, Sudan
| | - H Salah
- College of Medical Radiologic Science, Sudan University of Science and Technology, Khartoum, Sudan; INAYA Medical Collage, Nuclear Medicine Department, Riyadh, Saudi Arabia
| | - Nissren Tamam
- Department of Physics, College of Science, Princess Nourah bint Abdulrahman University, P.O. Box 84428 Riyadh 1167, Saudi Arabia
| | - Afaf Taha
- Prince Sattam Bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, Alkharj, Saudi Arabia
| | - Sali Dawood
- Prince Sattam Bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, Alkharj, Saudi Arabia
| | - D A Bradley
- Centre for Applied Physics and Radiation Technologies, School of Engineering and Technology, Sunway University, Bandar Sunway, 47500, Selangor, Malaysia; Centre for Nuclear and Radiation Physics, University of Surrey, Guildford, GU2 7XH, UK
| |
Collapse
|
3
|
Salah H, Rabbaa M, Abuljoud M, Babikir E, Alkhorayef M, Tamam N, Tahir D, Sulieman A, Bradley DA. Paediatric effective radiation doses during brain computed tomography angiography procedure. Appl Radiat Isot 2023; 192:110610. [PMID: 36525913 DOI: 10.1016/j.apradiso.2022.110610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Revised: 12/06/2022] [Accepted: 12/06/2022] [Indexed: 12/12/2022]
Abstract
In comparison to adults and paediatric are more sensitive to ionizing radiation exposure. Computed tomography (CT) is now the dominant source of medical radiologic tests for patients, accounting for more than 70% of total doses to the general public. Paediatric CT brain scans (with and without contrast) are routinely performed for a variety of clinical reasons. As a result, this parameter must be calculated in order to determine relative radiation risk. The goal of this study is to assess the radiation risk to children during CT brain diagnostic procedures. Three hundred fifty three child patients' radiation risk doses were assessed over the course of a year. The mean and ranged of the children's radiation doses were 40.6 ± 8.8 (27.8-45.8) CTDIvol (mGy) and 850 ± 230 (568.1-1126.4) DLP (mGy.cm) for the brain with contrast medium. For CT brain without contrast, the patients' doses were 40.9 ± 9.4 (14.27-64.07) CTDIvol (mGy), and 866.1 ± 289.3 (203.6-2484.9) DLP (mGy.cm). The characteristics related to the radiation dose were retrieved from the scan protocol generated by the CT system by the participating physicians after each procedure. Furthermore, optimizing the CT acquisition parameter is critical for increasing the benefit while lowering the procedure's radiogenic risk. The patients' radiation dose is comparable with the most previously published studies and international diagnostic reference levels (DRLs). Radiation dose optimization is recommended due to high sensitivity of the paediatric patients to ionizing radiation.
Collapse
Affiliation(s)
- H Salah
- INAYA Medical Collage, Nuclear Medicine Department, Riyadh, Saudi Arabia; College of Medical Radiologic Science, Sudan University of Science and Technology, Khartoum, Sudan.
| | - Mohammad Rabbaa
- Radiology Department, Riyadh Care Hospital, Riyadh, Saudi Arabia
| | | | - E Babikir
- Radiologic Technology Program, College of Health and Sport Sciences, University of Bahrain, Sakhir Campus, Zallaq, P.O. Box 32038, Bahrain
| | - M Alkhorayef
- Department of Radiological Sciences, College of Applied Medical Sciences, King Saud University, P.O Box 10219, Riyadh, 11433, Saudi Arabia
| | - N Tamam
- Department of Physics, College of Sciences, Princess Nourah bint Abdulrahman University, P.O Box 84428, Riyadh, 11671, Saudi Arabia
| | - Dahlang Tahir
- Department of Physics, Hasanuddin University, Makassar, 90245, Indonesia
| | - A Sulieman
- Prince Sattam bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P.O. Box 422, Alkharj, 11942, Saudi Arabia
| | - D A Bradley
- Centre for Nuclear and Radiation Physics, Department of Physics, University of Surrey, Guildford, United Kingdom; Centre for Applied Physics and Radiation Technologies, School of Engineering and Technology, Sunway University, 47500, Bandar Sunway, Selangor, Malaysia
| |
Collapse
|
4
|
Almujally A, Alenezi S, Alddosary KN, Otayni A, Sulieman A, Abdelghani A, Alkhybari E, Tamam N, Bradley D. Abdomen and pelvis computed tomography procedure: Effective dose assessment and establishment of a local diagnostic reference level. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
5
|
Abuzaid MM, Elshami W, Sulieman A, Bradley D. Cumulative radiation exposure, effective and organ dose estimation from multiple head CT scans in stroke patients. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110306] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
6
|
Evaluation of radiation exposure for patients undergoing computed tomography perfusion procedure for acute ischemic stroke. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110447] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
7
|
Omer H, Alameen S, Mahmoud WE, Sulieman A, Nasir O, Abolaban F. Eye lens and thyroid gland radiation exposure for patients undergoing brain computed tomography examination. Saudi J Biol Sci 2021; 28:342-346. [PMID: 33424315 PMCID: PMC7783653 DOI: 10.1016/j.sjbs.2020.10.010] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2020] [Revised: 10/04/2020] [Accepted: 10/06/2020] [Indexed: 11/13/2022] Open
Abstract
This study aims to estimate the effective radiation dose and organ dose from head CT procedures. It was conducted in three main private hospitals in Khartoum State-Sudan, using Toshiba machines with 64 slices. The total number of patients included in this study was 142 patients (82 males and 60 females). The effective dose and organ dose were calculated by CT Expo software. The effective dose slightly varied among patients according to gender and age. The effective dose for female patients (5.99 mSv) was higher than that for male patients (5.84 mSv), and the pediatric dose (5.46 mSv) was lower than the adults' dose (5.94 mSv). The dose for eye lens was found lower for male patients (89.117 mSv) than the dose for female patients (94.62) mSv). According to patients' age: the dose received by the lens of the eye was much lower in pediatric (79.93 mSv) than the adults (92.41 mSv). The dose for thyroid in female patients (33.52 mSv) was higher than the male patients (28 mSv). The pediatric dose (28.34 mSv) was lower than the adults' dose (30.64 mSv). Departmental imaging protocol and lack of training among hospital staff are expected to be responsible for these variations. Therefore, this study recommends that the CT technologists be trained on suitable strategies to achieve dose optimization. Moreover, patients' doses must be monitored regularly.
Collapse
Affiliation(s)
- Hiba Omer
- Department of Basic Sciences, Deanship of Preparatory Year and Supporting Studies, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 34212, Saudi Arabia
| | - Suhaib Alameen
- Sudan University of Science and Technology College of Medical Radiologic Science, P.O. Box 1908, Khartoum, Sudan
| | - Waleed E. Mahmoud
- Sudan University of Science and Technology College of Medical Radiologic Science, P.O. Box 1908, Khartoum, Sudan
| | - Abdelmoneim Sulieman
- Prince Sattam Bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, PO Box 422, Alkharj 11942, Saudi Arabia
| | - Omaima Nasir
- Department of Biology, Turabah University College, Taif University, P.O.Box 11099, Taif 21944, Saudi Arabia
| | - Fouad Abolaban
- Nuclear Engineering Department, Faculty of Engineering, King Abdulaziz University, P.O. Box 80204 Jeddah 21589 Saudi Arabia
| |
Collapse
|
8
|
Phantom dosimetry and cancer risks estimation undergoing 6 MV photon beam by an Elekta SL-25 linac. Appl Radiat Isot 2020; 163:109232. [PMID: 32561064 DOI: 10.1016/j.apradiso.2020.109232] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 04/25/2020] [Accepted: 05/17/2020] [Indexed: 01/15/2023]
Abstract
The High-energy linear accelerator (linac) is a valuable tool and the most commonly used devices for external beam radiation treatments in subjects suffer from cancer. To estimate the dose deposited in several organs of a female patient due to pelvic irradiation by an Elekta SL-25 linac in 6 MV photon beam mode, the MCNPX code is used considering the most details of linac. The equivalent dose in different organs is computed according to the face down position (prone) of MIRD and UFRO phantoms. The data obtained using MCNPX show that the received dose in all commons organs of MIRD and UFRO phantoms is 535.73 and 433.09 mSv/Gyx, respectively. The risks of second cancer incidence and mortality during radiotherapy treatment are compared between MIRD and UFRO phantoms. The results indicated that bladder has the maximum risk of secondary cancer incidence risk of 142.85 and 135.34 per 105 persons based on MIRD and UFRO phantoms, respectively; while the total risk is about 1 in 163 and about 1 in 101 in these phantoms.
Collapse
|
9
|
Sutanto H, Irdawati Y, Anam C, Fujibuchi T, Dougherty G, Hidayanto E, Arifin Z, Soedarsono JW, Bahrudin. An artifact-free thyroid shield in CT examination: a phantom study. Biomed Phys Eng Express 2020; 6:015029. [DOI: 10.1088/2057-1976/ab6ed1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
10
|
Roslee MAAM, Shuaib IL, Napi AFM, Razali MASM, Osman ND. Cumulative organ dose and effective dose in adult population underwent repeated or multiple head CT examination. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2019.108465] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
|
11
|
Irdawati Y, Sutanto H, Anam C, Fujibuchi T, Zahroh F, Dougherty G. Development of a novel artifact-free eye shield based on silicon rubber-lead composition in the CT examination of the head. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2019; 39:991-1005. [PMID: 31272094 DOI: 10.1088/1361-6498/ab2f3e] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
The aim of this work was to develop a novel artifact-free eye shield and evaluate its effect on the dose received by the eye lens and the resulting image quality in the CT examination of the head. A new material for an eye shield was synthesised from silicon rubber (SR) and lead (Pb) using a simple method. The percentage of Pb was varied from 0 to 5% wt. An anthropomorphic head phantom was scanned with and without the SR-Pb eye shield, and compared with a tungsten paper (WP) eye shield. The distance from the eye shield and head was varied from 0 to 5 cm. The dose to the eye lens was measured using photo-luminescence detectors (PLDs). The presence of artifacts was determined by measuring CT numbers at different eye lens locations and by subtracting images with and without the eye shield. The dose reduction increases with increasing Pb content in the SR-Pb eye shield. A 5% wt SR-Pb eye shield reduced the eye lens dose by up to 50%, whereas the WP eye shield reduced the dose by up to 86%. The CT numbers in images with the SR-Pb eye shield in the regions of both eyes and the center of the head phantom is similar to those without the eye shield, indicating that there is no artifact in the resulting image. Using the WP eye shield, there is considerable artifact with the CT number increasing by up to 700% in the regions of both eyes and the center of the head. It is found that the distance between the SR-Pb eye shield and the head does not affect either the dose or the resulting images. A SR-Pb-based eye shield can be applied in clinical environments and should be placed directly above the eye surface for dose optimisation.
Collapse
Affiliation(s)
- Yulia Irdawati
- Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Central Java, Indonesia
| | | | | | | | | | | |
Collapse
|