1
|
Fuentealba M, Ferreira A, Salgado A, Vergara C, Díez S, Santibáñez M. An Optimized Method for Evaluating the Potential Gd-Nanoparticle Dose Enhancement Produced by Electronic Brachytherapy. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:430. [PMID: 38470761 DOI: 10.3390/nano14050430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 01/08/2024] [Accepted: 01/11/2024] [Indexed: 03/14/2024]
Abstract
This work reports an optimized method to experimentally quantify the Gd-nanoparticle dose enhancement generated by electronic brachytherapy. The dose enhancement was evaluated considering energy beams of 50 kVp and 70 kVp, determining the Gd-nanoparticle concentration ranges that would optimize the process for each energy. The evaluation was performed using delaminated radiochromic films and a Poly(methyl methacrylate) (PMMA) phantom covered on one side by a thin 2.5 μm Mylar filter acting as an interface between the region with Gd suspension and the radiosensitive film substrate. The results for the 70 kVp beam quality showed dose increments of 6±6%, 22±7%, and 9±7% at different concentrations of 10, 20, and 30 mg/mL, respectively, verifying the competitive mechanisms of enhancement and attenuation. For the 50 kVp beam quality, no increase in dose was recorded for the concentrations studied, indicating that the major contribution to enhancement is from the K-edge interaction. In order to separate the contributions of attenuation and enhancement to the total dose, measurements were replicated with a 12 μm Mylar filter, obtaining a dose enhancement attributable to the K-edge of 29±7% and 34±7% at 20 and 30 mg/mL, respectively, evidencing a significant additional dose proportional to the Gd concentration.
Collapse
Affiliation(s)
- Melani Fuentealba
- Departamento de Cs. Físicas, Universidad de La Frontera, Temuco 4811230, Chile
- Laboratorio de Radiaciones Ionizantes, Universidad de La Frontera, Temuco 4811230, Chile
- Departamento de Fisiología, Universitat de Valencia, 46010 Valencia, Spain
| | - Alejandro Ferreira
- Facultad de Medicina y Ciencia, Universidad San Sebastián, Santiago 7510602, Chile
| | | | - Christopher Vergara
- Departamento de Cs. Físicas, Universidad de La Frontera, Temuco 4811230, Chile
- Laboratorio de Radiaciones Ionizantes, Universidad de La Frontera, Temuco 4811230, Chile
| | - Sergio Díez
- Departamento de Fisiología, Universitat de Valencia, 46010 Valencia, Spain
- Medical Physics Department, Hospital Clínico Universitario de Valencia, 46010 Valencia, Spain
| | - Mauricio Santibáñez
- Departamento de Cs. Físicas, Universidad de La Frontera, Temuco 4811230, Chile
- Laboratorio de Radiaciones Ionizantes, Universidad de La Frontera, Temuco 4811230, Chile
| |
Collapse
|
2
|
Gayol A, Malano F, Ribo Montenovo C, Pérez P, Valente M. Dosimetry Effects Due to the Presence of Fe Nanoparticles for Potential Combination of Hyperthermic Cancer Treatment with MRI-Based Image-Guided Radiotherapy. Int J Mol Sci 2022; 24:ijms24010514. [PMID: 36613959 PMCID: PMC9820326 DOI: 10.3390/ijms24010514] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/03/2022] [Accepted: 12/06/2022] [Indexed: 12/29/2022] Open
Abstract
Nanoparticles have proven to be biocompatible and suitable for many biomedical applications. Currently, hyperthermia cancer treatments based on Fe nanoparticle infusion excited by alternating magnetic fields are commonly used. In addition to this, MRI-based image-guided radiotherapy represents, nowadays, one of the most promising accurate radiotherapy modalities. Hence, assessing the feasibility of combining both techniques requires preliminary characterization of the corresponding dosimetry effects. The present work reports on a theoretical and numerical simulation feasibility study aimed at pointing out preliminary dosimetry issues. Spatial dose distributions incorporating magnetic nanoparticles in MRI-based image-guided radiotherapy have been obtained by Monte Carlo simulation approaches accounting for all relevant radiation interaction properties as well as charged particles coupling with strong external magnetic fields, which are representative of typical MRI-LINAC devices. Two main effects have been evidenced: local dose enhancement (up to 60% at local level) within the infused volume, and non-negligible changes in the dose distribution at the interfaces between different tissues, developing to over 70% for low-density anatomical cavities. Moreover, cellular uptakes up to 10% have been modeled by means of considering different Fe nanoparticle concentrations. A theoretical temperature-dependent model for the thermal enhancement ratio (TER) has been used to account for radiosensitization due to hyperthermia. The outcomes demonstrated the reliability of the Monte Carlo approach in accounting for strong magnetic fields and mass distributions from patient-specific anatomy CT scans to assess dose distributions in MRI-based image-guided radiotherapy combined with magnetic nanoparticles, while the hyperthermic radiosensitization provides further and synergic contributions.
Collapse
Affiliation(s)
- Amiel Gayol
- Instituto de Física E. Gaviola (IFEG), CONICET & Facultad de Matemática, Astronomía, Física y Computación (FAMAF), Universidad Nacional de Córdoba, Ciudad Universitaria, Córdoba 5000, Argentina
- Laboratorio de Investigación e Instrumentación en Física Aplicada a la Medicina e Imágenes por Rayos X (LIIFAMIRx), Facultad de Matemática, Astronomía, Física y Computación (FAMAF), Universidad Nacional de Córdoba, Ciudad Universitaria, Córdoba 5000, Argentina
| | - Francisco Malano
- Centro de Excelencia de Física e Ingeniería en Salud (CFIS), Departamento de Ciencias Físicas, Universidad de La Frontera, Av. Salazar 01145, Casilla 54D, Temuco 4811230, Chile
- Correspondence: (F.M.); (M.V.)
| | - Clara Ribo Montenovo
- Laboratorio de Investigación e Instrumentación en Física Aplicada a la Medicina e Imágenes por Rayos X (LIIFAMIRx), Facultad de Matemática, Astronomía, Física y Computación (FAMAF), Universidad Nacional de Córdoba, Ciudad Universitaria, Córdoba 5000, Argentina
| | - Pedro Pérez
- Instituto de Física E. Gaviola (IFEG), CONICET & Facultad de Matemática, Astronomía, Física y Computación (FAMAF), Universidad Nacional de Córdoba, Ciudad Universitaria, Córdoba 5000, Argentina
- Laboratorio de Investigación e Instrumentación en Física Aplicada a la Medicina e Imágenes por Rayos X (LIIFAMIRx), Facultad de Matemática, Astronomía, Física y Computación (FAMAF), Universidad Nacional de Córdoba, Ciudad Universitaria, Córdoba 5000, Argentina
| | - Mauro Valente
- Instituto de Física E. Gaviola (IFEG), CONICET & Facultad de Matemática, Astronomía, Física y Computación (FAMAF), Universidad Nacional de Córdoba, Ciudad Universitaria, Córdoba 5000, Argentina
- Laboratorio de Investigación e Instrumentación en Física Aplicada a la Medicina e Imágenes por Rayos X (LIIFAMIRx), Facultad de Matemática, Astronomía, Física y Computación (FAMAF), Universidad Nacional de Córdoba, Ciudad Universitaria, Córdoba 5000, Argentina
- Centro de Excelencia de Física e Ingeniería en Salud (CFIS), Departamento de Ciencias Físicas, Universidad de La Frontera, Av. Salazar 01145, Casilla 54D, Temuco 4811230, Chile
- Correspondence: (F.M.); (M.V.)
| |
Collapse
|
3
|
Körnig C, Staufer T, Schmutzler O, Bedke T, Machicote A, Liu B, Liu Y, Gargioni E, Feliu N, Parak WJ, Huber S, Grüner F. In-situ x-ray fluorescence imaging of the endogenous iodine distribution in murine thyroids. Sci Rep 2022; 12:2903. [PMID: 35190621 PMCID: PMC8861059 DOI: 10.1038/s41598-022-06786-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Accepted: 02/04/2022] [Indexed: 12/27/2022] Open
Abstract
X-ray fluorescence imaging (XFI) is a non-invasive detection method of small quantities of elements, which can be excited to emit fluorescence x-ray photons upon irradiation with an incident x-ray beam. In particular, it can be used to measure nanoparticle uptake in cells and tissue, thus making it a versatile medical imaging modality. However, due to substantially increased multiple Compton scattering background in the measured x-ray spectra, its sensitivity severely decreases for thicker objects, so far limiting its applicability for tracking very small quantities under in-vivo conditions. Reducing the detection limit would enable the ability to track labeled cells, promising new insights into immune response and pharmacokinetics. We present a synchrotron-based approach for reducing the minimal detectable marker concentration by demonstrating the feasibility of XFI for measuring the yet inaccessible distribution of the endogenous iodine in murine thyroids under in-vivo conform conditions. This result can be used as a reference case for the design of future preclinical XFI applications as mentioned above.
Collapse
Affiliation(s)
- Christian Körnig
- Fachbereich Physik, Universität Hamburg and Center for Free-Electron Laser Science (CFEL), Luruper Chaussee 149, 22761, Hamburg, Germany
| | - Theresa Staufer
- Fachbereich Physik, Universität Hamburg and Center for Free-Electron Laser Science (CFEL), Luruper Chaussee 149, 22761, Hamburg, Germany
| | - Oliver Schmutzler
- Fachbereich Physik, Universität Hamburg and Center for Free-Electron Laser Science (CFEL), Luruper Chaussee 149, 22761, Hamburg, Germany
| | - Tanja Bedke
- I. Department of Medicine, Hamburg Center for Translational Immunology (HCTI), University Medical Center Hamburg-Eppendorf, 20246, Hamburg, Germany
| | - Andres Machicote
- I. Department of Medicine, Hamburg Center for Translational Immunology (HCTI), University Medical Center Hamburg-Eppendorf, 20246, Hamburg, Germany
| | - Beibei Liu
- I. Department of Medicine, Hamburg Center for Translational Immunology (HCTI), University Medical Center Hamburg-Eppendorf, 20246, Hamburg, Germany
| | - Yang Liu
- Fachbereich Physik, Universität Hamburg and Center for Hybrid Nanostructures (CHyN), Luruper Chaussee 149, 22761, Hamburg, Germany
| | - Elisabetta Gargioni
- Department of Radiotherapy and Radiation Oncology, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany
| | - Neus Feliu
- Fachbereich Physik, Universität Hamburg and Center for Hybrid Nanostructures (CHyN), Luruper Chaussee 149, 22761, Hamburg, Germany
- Fraunhofer Center for Applied Nanotechnology (CAN), Grindelallee 117, Hamburg, Germany
| | - Wolfgang J Parak
- Fachbereich Physik, Universität Hamburg and Center for Hybrid Nanostructures (CHyN), Luruper Chaussee 149, 22761, Hamburg, Germany
| | - Samuel Huber
- I. Department of Medicine, Hamburg Center for Translational Immunology (HCTI), University Medical Center Hamburg-Eppendorf, 20246, Hamburg, Germany
| | - Florian Grüner
- Fachbereich Physik, Universität Hamburg and Center for Free-Electron Laser Science (CFEL), Luruper Chaussee 149, 22761, Hamburg, Germany.
| |
Collapse
|
4
|
Experimental characterization and Monte Carlo simulations of the dose enhancement on the millimeter scale of PAGAT infused with gadolinium. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109533] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
5
|
Pedrosa P, Baptista PV, Fernandes AR, Guerra M. Benchtop X-ray fluorescence imaging as a tool to study gold nanoparticle penetration in 3D cancer spheroids. RSC Adv 2021; 11:26344-26353. [PMID: 35479447 PMCID: PMC9037313 DOI: 10.1039/d1ra05446e] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 07/22/2021] [Indexed: 12/20/2022] Open
Abstract
The use of nanomaterials to improve medical diagnostics and therapeutics has been rapidly increasing. Among these materials are gold nanoparticles, which can be functionalized to target specific cells, acting as nanovectors for drug delivery, enhanced contrast agents as well as other targeted therapies. Au nanoparticles are very useful as they selectively accumulate in tumour sites due to the enhanced permeability-retention effect. There is however little information about the spatial distribution of the nanoparticles within tumours, which might hinder efficient therapies. In this study, X-ray fluorescence was used to investigate the diffusion of gold nanoparticles in cancer cell spheroids mimicking true tumour growth. Functionalization of the nanoparticles has the effect of allowing better diffusion into and out of the spheroid, while those nanoparticles that are only partially covered rapidly formed aggregates. This clustering led to size exclusion during transport within the tumour, changing its distribution profile while greatly increasing the nanoparticle concentration.
Collapse
Affiliation(s)
- Pedro Pedrosa
- UCIBIO, Departamento de Ciências da Vida, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa 2892-516 Caparica Portugal
| | - Pedro V Baptista
- UCIBIO, Departamento de Ciências da Vida, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa 2892-516 Caparica Portugal
| | - Alexandra R Fernandes
- UCIBIO, Departamento de Ciências da Vida, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa 2892-516 Caparica Portugal
| | - Mauro Guerra
- Laboratory of Instrumentation, Biomedical Engineering and Radiation Physics (LIBPhys-UNL), Department of Physics, NOVA School of Science and Technology, NOVA University Lisbon 2829-516 Caparica Portugal
| |
Collapse
|
6
|
Santibáñez M, Fuentealba M. Experimental determination of Gd dose enhancement and Gd dose sparing by 192Ir brachytherapy source with Gafchromic EBT3 dosimeter. Appl Radiat Isot 2021; 175:109787. [PMID: 34102413 DOI: 10.1016/j.apradiso.2021.109787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Revised: 05/13/2021] [Accepted: 05/18/2021] [Indexed: 10/21/2022]
Abstract
This work evaluates experimentally the dose enhancement factor (DEF) and dose sparing factor (DSF) due to radiation self-shielding, produced by Gd infused in tumor phantom irradiated with brachytherapy HDR 192Ir source by Gafchromic EBT3 dosimeter. The phantom was made of a set of solid water slabs (30 × 30 × 1.0) cm3 and three acrylic slabs of (30 × 30 × 0.5) cm3 machined to contain in the central axis acrylics vials of (1 × 1 × 5) cm3. The first and second acrylic vials were filled with an identical Gd solution of 0, 10 and 20 mg/ml, simulating Gd-doped and undoped tumor, and the third vial was filled in all the measurement only with water, representing an organ at risk. Additional solid water slabs were used to complete a phantom of (30 × 30 × 16) cm3. In the phantom center an acrylic slab was machined to introduce the 2.5 mm flexible guide tube of GammaMed plus iX equipment and positioning the 192Ir source in the phantom central part. EBT3 fragments of (0.9 × 4) cm2 were placed on the inner edge of the second and third vials to measure dose enhancement and dose sparing simultaneously. Phantom CT images were acquired for planning and to prescribe a dose of 6.0 Gy at 2.0 cm of the source, achieving an isodose curve of 44.5% at 3.0 cm (positions of the EBT3 films). Additionally, Monte Carlo simulation of the identical experimental setup was implemented to compare measurement values. The results showed the feasibility of measuring a DEF of 1.15 ± 0.05 in 20 mg/ml of Gd concentration consistent with the Monte Carlo DEF of 1.112 ± 0.005 for the same concentration. DEF value for concentration of 10 mg/ml would not be detected (1.00 ± 0.04) by an expected under measurement of the EBT3 films associated with the non-detection of photoelectrons and Auger electrons of very low energy that cannot reach the radiosensitive substrate.
Collapse
Affiliation(s)
- M Santibáñez
- Departamento de Cs. Físicas, Universidad de La Frontera, Temuco, Chile.
| | - M Fuentealba
- Hospital Regional Dr. Guillermo Grant Benavente, Concepción, Chile
| |
Collapse
|
7
|
Fuentealba M, Santibáñez M. Monte Carlo evaluation of the dose sparing and dose enhancement by combination of Gd-infused tumor and 241Am source for an endocavitary brachytherapy geometry. Appl Radiat Isot 2020; 163:109194. [DOI: 10.1016/j.apradiso.2020.109194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2019] [Revised: 04/06/2020] [Accepted: 04/08/2020] [Indexed: 10/24/2022]
|
8
|
Santibáñez M, Fuentealba M, Torres F, Vargas A. Experimental determination of the gadolinium dose enhancement in phantom irradiated with low energy X-ray sources by a spectrophotometer -Gafchromic-EBT3 dosimetry system. Appl Radiat Isot 2019; 154:108857. [PMID: 31434044 DOI: 10.1016/j.apradiso.2019.108857] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2018] [Revised: 08/10/2019] [Accepted: 08/12/2019] [Indexed: 01/22/2023]
Abstract
This work reports the experimental determination of dose enhancement produced in phantoms containing target volumes doped with Gadolinium and irradiated with low-energy X-ray beams. EBT3 Gafchromic films were immersed into 5 ml target volumes to simulate tumor filling with 100% ultra-pure water (blank sample) and ultra-pure water infused with Gd solution (Omniscan®) in different concentration (9-24 mg/ml). The dose enhancement due to excitation of Gd K-edge (50.2 keV) was evaluated in terms of the increment in optical density, obtained by a Spectrophotometer-Gafchromic-EBT3 dosimetry system calibrated in terms of the dose-response for 1-8 Gy range. The dose enhancement was evaluated in two condition: a beam quality with spectrum above the absorption edge in a medium with and without Gd; and two beam qualities (above and below the absorption edge) in a medium with a fixed Gd concentration (18 mg/ml). The obtained results confirmed increments in relative dose enhancement according to Gd concentrations up to 18 mg/ml, with a dose enhancement of 1.1 Gy and an average percentage enhancement of 28.4%. For higher values of concentration, the attenuation interaction of the primary beam is more relevant instead of dose enhancement process. On the other hand, the dose enhancement obtained to comparison the spectra above and below the absorption edge, shown results up to 3.3 Gy of enhancement and average percentage enhancement of 88%.
Collapse
Affiliation(s)
- M Santibáñez
- Departamento de Ciencias Físicas, Universidad de La Frontera, F. Salazar, 01145, Temuco, Chile; Centro de Física e Ingeniería en Medicina (CFIM), Facultad de Ingenieria y Ciencias, Universidad de La Frontera, Temuco, Chile.
| | - M Fuentealba
- Departamento de Ciencias Físicas, Universidad de La Frontera, F. Salazar, 01145, Temuco, Chile
| | - F Torres
- Departamento de Ciencias Físicas, Universidad de La Frontera, F. Salazar, 01145, Temuco, Chile
| | - A Vargas
- Departamento de Ciencias Físicas, Universidad de La Frontera, F. Salazar, 01145, Temuco, Chile
| |
Collapse
|