1
|
Aboul Hamad MS, Attalla EM, Amer HH, Fathy MM. Assessment of diagnostic reference levels for paediatric cardiac computed tomography in accordance with European guidelines. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2023:10.1007/s00411-023-01031-6. [PMID: 37349577 DOI: 10.1007/s00411-023-01031-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Accepted: 05/20/2023] [Indexed: 06/24/2023]
Abstract
Recently, paediatric cardiac computed tomography (CCT) has caused concerns that diagnostic image quality and dose reduction may require further improvement. Consequently, this study aimed to establish institutional (local) diagnostic reference levels (LDRLs) for CCT for paediatric patients, and assess the impact of tube voltage on proposed DRLs in terms of the volume computed tomography index (CTDIvol) and dose length product (DLP). In addition, effective doses (EDs) of exposure were estimated. A population of 453 infants, whose mass and age were less than 12 kg and 2 years, respectively, were considered from January 2018 to August 2021. Based on previous studies, this number of patients was considered to be sufficient for establishing LDRLs. A group of 245 patients underwent CCT examinations at 70 kVp tube voltage with an average scan range of 23.4 cm. Another set of 208 patients underwent CCT examinations at 100 kVp tube voltage with an average scan range of 15.8 cm. The observed CTDIvol and DLP values were 2.8 mGy and 54.8 mGy.cm, respectively. The mean effective dose (ED) was 1.2 mSv. It is concluded that provisional establishment and use of DRLs for cardiac computed tomography in children are crucial, and further research is needed to develop regional and international DRLs.
Collapse
Affiliation(s)
- Mohamed S Aboul Hamad
- Biophysics Department, Faculty of Science, Cairo University, Giza, Egypt.
- Radiology Department, ALNas Hospital, Cairo, Egypt.
| | - Ehab M Attalla
- National Cancer Institute, Cairo University, Giza, Egypt
| | - Hanan H Amer
- Biophysics Department, Faculty of Science, Cairo University, Giza, Egypt
| | - Mohamed M Fathy
- Biophysics Department, Faculty of Science, Cairo University, Giza, Egypt
| |
Collapse
|
2
|
Salah H, Rabbaa M, Abuljoud M, Babikir E, Alkhorayef M, Tamam N, Tahir D, Sulieman A, Bradley DA. Paediatric effective radiation doses during brain computed tomography angiography procedure. Appl Radiat Isot 2023; 192:110610. [PMID: 36525913 DOI: 10.1016/j.apradiso.2022.110610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Revised: 12/06/2022] [Accepted: 12/06/2022] [Indexed: 12/12/2022]
Abstract
In comparison to adults and paediatric are more sensitive to ionizing radiation exposure. Computed tomography (CT) is now the dominant source of medical radiologic tests for patients, accounting for more than 70% of total doses to the general public. Paediatric CT brain scans (with and without contrast) are routinely performed for a variety of clinical reasons. As a result, this parameter must be calculated in order to determine relative radiation risk. The goal of this study is to assess the radiation risk to children during CT brain diagnostic procedures. Three hundred fifty three child patients' radiation risk doses were assessed over the course of a year. The mean and ranged of the children's radiation doses were 40.6 ± 8.8 (27.8-45.8) CTDIvol (mGy) and 850 ± 230 (568.1-1126.4) DLP (mGy.cm) for the brain with contrast medium. For CT brain without contrast, the patients' doses were 40.9 ± 9.4 (14.27-64.07) CTDIvol (mGy), and 866.1 ± 289.3 (203.6-2484.9) DLP (mGy.cm). The characteristics related to the radiation dose were retrieved from the scan protocol generated by the CT system by the participating physicians after each procedure. Furthermore, optimizing the CT acquisition parameter is critical for increasing the benefit while lowering the procedure's radiogenic risk. The patients' radiation dose is comparable with the most previously published studies and international diagnostic reference levels (DRLs). Radiation dose optimization is recommended due to high sensitivity of the paediatric patients to ionizing radiation.
Collapse
Affiliation(s)
- H Salah
- INAYA Medical Collage, Nuclear Medicine Department, Riyadh, Saudi Arabia; College of Medical Radiologic Science, Sudan University of Science and Technology, Khartoum, Sudan.
| | - Mohammad Rabbaa
- Radiology Department, Riyadh Care Hospital, Riyadh, Saudi Arabia
| | | | - E Babikir
- Radiologic Technology Program, College of Health and Sport Sciences, University of Bahrain, Sakhir Campus, Zallaq, P.O. Box 32038, Bahrain
| | - M Alkhorayef
- Department of Radiological Sciences, College of Applied Medical Sciences, King Saud University, P.O Box 10219, Riyadh, 11433, Saudi Arabia
| | - N Tamam
- Department of Physics, College of Sciences, Princess Nourah bint Abdulrahman University, P.O Box 84428, Riyadh, 11671, Saudi Arabia
| | - Dahlang Tahir
- Department of Physics, Hasanuddin University, Makassar, 90245, Indonesia
| | - A Sulieman
- Prince Sattam bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P.O. Box 422, Alkharj, 11942, Saudi Arabia
| | - D A Bradley
- Centre for Nuclear and Radiation Physics, Department of Physics, University of Surrey, Guildford, United Kingdom; Centre for Applied Physics and Radiation Technologies, School of Engineering and Technology, Sunway University, 47500, Bandar Sunway, Selangor, Malaysia
| |
Collapse
|
3
|
A survey of the pediatric radiation doses during multiphase abdominal computed tomography examinations. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109662] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|