• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4643724)   Today's Articles (144)   Subscriber (50641)
For: Pablos JL, Ibeas S, Muñoz A, Serna F, García FC, García JM. Solid polymer and metallogel networks based on a fluorene derivative as fluorescent and colourimetric chemosensors for Hg(II). REACT FUNCT POLYM 2014. [DOI: 10.1016/j.reactfunctpolym.2014.02.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Number Cited by Other Article(s)
1
Udhayakumari D. A review on polycyclic aromatic compounds based chemosensors for toxic ions detection - Present and future perspective. Talanta 2024;278:126536. [PMID: 39003838 DOI: 10.1016/j.talanta.2024.126536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Revised: 06/25/2024] [Accepted: 07/08/2024] [Indexed: 07/16/2024]
2
Wang H, Qiu N, Kong X, Hu Z, Zhong F, Tan H. Phenothiazine-based porous organic polymers with high sensitivity and selective fluorescence response to mercury ions. J SOLID STATE CHEM 2022. [DOI: 10.1016/j.jssc.2022.123522] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
3
Turn-off fluorene-based chemosensor switch to Fe3+: Spectroscopic study, merit parameters, theoretical calculations, and its application in Brazilian ethanol fuel. Inorganica Chim Acta 2021. [DOI: 10.1016/j.ica.2021.120511] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
4
A turn on fluorescent sensor for detecting Al3+ and colorimetric detection for Cu2+: Synthesis, cytotoxicity and on-site assay kit. J Photochem Photobiol A Chem 2021. [DOI: 10.1016/j.jphotochem.2021.113290] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
5
Zn(II) detection in biological samples with a smart sensory polymer. REACT FUNCT POLYM 2020. [DOI: 10.1016/j.reactfunctpolym.2020.104685] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
6
Zhao X, Wang N, Chen H, Bai L, Xu H, Wang W, Yang H, Wei D, Yang L. Fabrication of nanoprobe via AGET ATRP and photocatalytic modification for highly sensitive detection of Hg(II). REACT FUNCT POLYM 2019. [DOI: 10.1016/j.reactfunctpolym.2019.02.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
7
Sanjuán AM, Reglero Ruiz JA, García FC, García JM. Recent developments in sensing devices based on polymeric systems. REACT FUNCT POLYM 2018. [DOI: 10.1016/j.reactfunctpolym.2018.10.007] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
8
Smart Polymers in Micro and Nano Sensory Devices. CHEMOSENSORS 2018. [DOI: 10.3390/chemosensors6020012] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
9
Zhang M, Weiss RG. Mechano-switchable, luminescent gels derived from salts of a long-chained, fatty-acid gelator. Phys Chem Chem Phys 2018;18:20399-409. [PMID: 27400800 DOI: 10.1039/c6cp03435g] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
10
Tajbakhsh M, Chalmardi GB, Bekhradnia A, Hosseinzadeh R, Hasani N, Amiri MA. A new fluorene-based Schiff-base as fluorescent chemosensor for selective detection of Cr3+ and Al3. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2018;189:22-31. [PMID: 28787623 DOI: 10.1016/j.saa.2017.08.007] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/04/2017] [Revised: 07/06/2017] [Accepted: 08/01/2017] [Indexed: 05/12/2023]
11
Zhang M, Weiss RG. Insights into the Gelating Abilities of Ricinelaidic Acid and its Ammonium Salts: How do Stereochemistry, Charge, and Chain Lengths Control Gelation of a Long-Chain Alkenoic Acid? Chemphyschem 2016;17:4059-4067. [DOI: 10.1002/cphc.201600902] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2016] [Indexed: 11/06/2022]
12
C2-Symmetric Benzene-based Low Molecular Weight Hydrogel Modified Electrode for Highly Sensitive Detection of Copper Ions. Electrochim Acta 2015. [DOI: 10.1016/j.electacta.2015.04.110] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA