1
|
Bonanad C, Raposeiras-Roubin S, García-Blas S, Núñez-Gil I, Vergara-Uzcategui C, Díez-Villanueva P, Bañeras J, Badía Molins C, Aboal J, Carreras J, Bodi V, Gabaldón-Pérez A, Mateus-Porta G, Parada Barcia JA, Martínez-Sellés M, Chorro FJ, Ariza-Solé A. Evaluation of the Use of Dual Antiplatelet Therapy beyond the First Year after Acute Coronary Syndrome. J Clin Med 2022; 11:1680. [PMID: 35330004 PMCID: PMC8955645 DOI: 10.3390/jcm11061680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 03/15/2022] [Accepted: 03/15/2022] [Indexed: 01/27/2023] Open
Abstract
Clinical practice guidelines recommend extending dual antiplatelet therapy (DAPT) beyond 1 year after acute coronary syndrome (ACS) in patients with high ischemic risk and without high bleeding risk. The aim of this study was to identify variables associated with DAPT prolongation in a cohort of 1967 consecutive patients discharged after ACS without thrombotic or hemorrhagic events during the following year. The sample was stratified according to whether DAPT was extended beyond 1 year, and the factors associated with this strategy were analyzed. In 32.2% of the patients, DAPT was extended beyond 1 year. Overall, 770 patients (39.1%) were considered candidates for extended treatment based on PEGASUS criteria and absence of high bleeding risk, and DAPT was extended in 34.4% of them. The presence of a PEGASUS criterion was associated with extended DAPT in the univariate analysis, but not history of bleeding or a high bleeding risk. In the multivariate analysis, a history of percutaneous coronary intervention (odds ratio (OR) = 1.8, 95% confidence interval (CI) 1.4-2.4), stent thrombosis (OR = 3.8, 95% CI 1.7-8.9), coronary artery disease complexity (OR = 1.3, 95% CI 1.1-1.5), reinfarction (OR = 4.1, 95% CI 1.6-10.4), and clopidogrel use (OR = 1.3, 95% CI 1.1-1.6) were significantly associated with extended use. DAPT was extended in 32.2% of patients who survived ACS without thrombotic or hemorrhagic events. This percentage was 34.4% when the candidates were analyzed according to clinical guidelines. Neither the PEGASUS criteria nor the bleeding risk was independently associated with this strategy.
Collapse
Affiliation(s)
- Clara Bonanad
- Cardiology Department, Hospital Clínico Universitario de Valencia, 46010 Valencia, Spain; (C.B.); (S.G.-B.); (V.B.); (A.G.-P.); (F.J.C.)
- Department of Cardiology, INCLIVA Biomedical Research Institute, 46010 Valencia, Spain
- Department of Medicine, University of Valencia, 46010 Valencia, Spain
| | - Sergio Raposeiras-Roubin
- Cardiology Department, Hospital Universitario Álvaro Cunqueiro de Vigo, 36213 Vigo, Spain; (S.R.-R.); (J.A.P.B.)
| | - Sergio García-Blas
- Cardiology Department, Hospital Clínico Universitario de Valencia, 46010 Valencia, Spain; (C.B.); (S.G.-B.); (V.B.); (A.G.-P.); (F.J.C.)
- Department of Cardiology, INCLIVA Biomedical Research Institute, 46010 Valencia, Spain
- Department of Medicine, University of Valencia, 46010 Valencia, Spain
| | - Iván Núñez-Gil
- Cardiology Department, Hospital Clínico San Carlos, 28040 Madrid, Spain; (I.N.-G.); (C.V.-U.)
| | | | | | - Jordi Bañeras
- Cardiology Department, Hospital Universitari Vall d’Hebrón, 08035 Barcelona, Spain; (J.B.); (C.B.M.)
| | - Clara Badía Molins
- Cardiology Department, Hospital Universitari Vall d’Hebrón, 08035 Barcelona, Spain; (J.B.); (C.B.M.)
| | - Jaime Aboal
- Cardiology Department, Hospital Josep Trueta, 17007 Girona, Spain;
| | - Jose Carreras
- Cardiology Department, Hospital del Mar, 08003 Barcelona, Spain;
| | - Vicente Bodi
- Cardiology Department, Hospital Clínico Universitario de Valencia, 46010 Valencia, Spain; (C.B.); (S.G.-B.); (V.B.); (A.G.-P.); (F.J.C.)
- Department of Cardiology, INCLIVA Biomedical Research Institute, 46010 Valencia, Spain
- Department of Medicine, University of Valencia, 46010 Valencia, Spain
| | - Ana Gabaldón-Pérez
- Cardiology Department, Hospital Clínico Universitario de Valencia, 46010 Valencia, Spain; (C.B.); (S.G.-B.); (V.B.); (A.G.-P.); (F.J.C.)
| | - Gemma Mateus-Porta
- Cardiology Department, Hospital Universitari de Bellvitge, L’Hospitalet de Llobregat, 08907 Barcelona, Spain;
- Bioheart Grup de Malalties Cardiovasculars, Institut d’Investigació Biomèdica de Bellvitge—IDIBELL, L’Hospitalet de Llobregat, 08908 Barcelona, Spain
| | - Jose Antonio Parada Barcia
- Cardiology Department, Hospital Universitario Álvaro Cunqueiro de Vigo, 36213 Vigo, Spain; (S.R.-R.); (J.A.P.B.)
| | | | - Francisco Javier Chorro
- Cardiology Department, Hospital Clínico Universitario de Valencia, 46010 Valencia, Spain; (C.B.); (S.G.-B.); (V.B.); (A.G.-P.); (F.J.C.)
- Department of Cardiology, INCLIVA Biomedical Research Institute, 46010 Valencia, Spain
- Department of Medicine, University of Valencia, 46010 Valencia, Spain
| | - Albert Ariza-Solé
- Cardiology Department, Hospital Universitari de Bellvitge, L’Hospitalet de Llobregat, 08907 Barcelona, Spain;
- Bioheart Grup de Malalties Cardiovasculars, Institut d’Investigació Biomèdica de Bellvitge—IDIBELL, L’Hospitalet de Llobregat, 08908 Barcelona, Spain
| |
Collapse
|
2
|
Martín-Rodríguez F, Sanz-García A, Castro-Portillo E, Delgado-Benito JF, Del Pozo Vegas C, Ortega Rabbione G, Martín-Herrero F, Martín-Conty JL, López-Izquierdo R. Prehospital troponin as a predictor of early clinical deterioration. Eur J Clin Invest 2021; 51:e13591. [PMID: 34002363 DOI: 10.1111/eci.13591] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2020] [Revised: 02/01/2021] [Accepted: 04/09/2021] [Indexed: 12/19/2022]
Abstract
BACKGROUND AND OBJECTIVES Elevated troponin T (cTnT) values are associated with comorbidities and early mortality, in both cardiovascular and noncardiovascular diseases. The objective of this study is to evaluate the prognostic accuracy of the sole utilization of prehospital point-of-care cardiac troponin T to identify the risk of early in-hospital deterioration, including mortality within 28 days. METHODS We conducted a prospective, multicentric, controlled, ambulance-based, observational study in adults with acute diseases transferred with high priority by ambulance to emergency departments, between 1 January and 30 September 2020. Patients with hospital diagnosis of acute coronary syndrome were excluded. The discriminative power of the predictive cTnT was assessed through a discrimination model trained using a derivation cohort and evaluated by the area under the curve of the receiver operating characteristic on a validation cohort. RESULTS A total of 848 patients were included in our study. The median age was 68 years (25th-75th percentiles: 50-81 years), and 385 (45.4%) were women. The mortality rate within 28 days was 12.4% (156 cases). The predictive ability of cTnT to predict mortality presented an area under the curve of 0.903 (95% CI: 0.85-0.954; P < .001). Risk stratification was performed, resulting in three categories with the following optimal cTnT cut-off points: high risk greater than or equal to 100, intermediate risk 40-100 and low risk less than 40 ng/L. In the high-risk group, the mortality rate was 61.7%, and on the contrary, the low-risk group presented a mortality of 2.3%. CONCLUSIONS The implementation of a routine determination of cTnT on the ambulance in patients transferred with high priority to the emergency department can help to stratify the risk of these patients and to detect unknown early clinical deterioration.
Collapse
Affiliation(s)
- Francisco Martín-Rodríguez
- Advanced Life Support Unit, Gerencia de Emergencias Sanitarias, Gerencia Regional de Salud de Castilla y León (SACYL), Valladolid, Spain.,Advanced Clinical Simulation Center, Medicine Faculty, Valladolid University, Valladolid, Spain
| | - Ancor Sanz-García
- Data Analysis Unit, Health Research Institute, Hospital de la Princesa, Madrid (IIS-IP), Spain
| | - Enrique Castro-Portillo
- Emergency Department, Hospital Universitario Rio Hortega de Valladolid, Gerencia Regional de Salud de Castilla y León (SACYL), Salamanca, Spain
| | - Juan F Delgado-Benito
- Advanced Life Support Unit, Gerencia de Emergencias Sanitarias, Gerencia Regional de Salud de Castilla y León (SACYL), Valladolid, Spain
| | - Carlos Del Pozo Vegas
- Emergency Department, Hospital Clínico Universitario de Valladolid, Gerencia Regional de Salud de Castilla y León (SACYL), Salamanca, Spain
| | - Guillermo Ortega Rabbione
- Data Analysis Unit, Health Research Institute, Hospital de la Princesa, Madrid (IIS-IP), Spain.,National Scientific and Technical Research Council (CONICET), Buenos Aires, Argentina
| | - Francisco Martín-Herrero
- Department of Cardiology, Complejo Asistencial de Salamanca, Gerencia Regional de Salud de Castilla y León (SACYL), Salamanca, Spain
| | - José Luis Martín-Conty
- Faculty of Health Sciences, Universidad de Castilla la Mancha, Talavera de la Reina, Spain
| | - Raúl López-Izquierdo
- Emergency Department, Hospital Universitario Rio Hortega de Valladolid, Gerencia Regional de Salud de Castilla y León (SACYL), Salamanca, Spain
| |
Collapse
|