1
|
Yan CL, Zhang YQY, Chen Y, Qv ZY, Zuo MZ. To compare the influence of blind insertion and up-down optimized glottic exposure manoeuvre on oropharyngeal leak pressure using SaCoVLM™ video laryngeal mask among patients undergoing general anesthesia. J Clin Monit Comput 2023; 37:593-598. [PMID: 36308611 PMCID: PMC10068663 DOI: 10.1007/s10877-022-00930-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Accepted: 10/06/2022] [Indexed: 10/31/2022]
Abstract
To compare the potential influences of blind insertion and up-down optimized glottic exposure manoeuvre on the oropharyngeal leak pressure (OPLP) in using SaCoVLM™ video laryngeal mask (VLM) among patients undergoing general anesthesia. A randomized self-control study controlled was conducted to investigate the effect of two insertion techniques on OPLP. A total of 60 patients (male or female, 18-78 years, BMI 18.0-30.0 kg m-2 and ASA I-II) receiving selective surgery under general anesthesia were randomly recruited. After induction of anesthesia, the SaCoVLM™ was inserted by blind insertion manoeuvre. The glottic exposure grading(V1) of the SaCoVLM™ visual laryngeal mask and the OPLP(P1) were recorded. And the glottic exposure grading(V2) and OPLP(P2) of SaCoVLM™ were recorded again when the glottic exposure grading was optimal. The glottis exposure grading and OPLP were compared before and after different insertion manoeuver. The glottic exposure grading (V2) obtained by using up-down optimized glottic exposure manoeuvre was better than that obtained by using blind insertion manoeuvre (V1)(P < 0.001). The OPLP was significantly lower in the blind insertion manoeuvre (P1) than in the up-down optimized glottic exposure manoeuvre (P2) (32.4 ± 5.0 cmH2O vs. 36.3 ± 5.2 cmH2O, P < 0.001). In using SaCoVLM™, higher OPLP and better glottic exposure grading were achieved through up-down optimized glottic exposure manoeuvre, protecting the airway while real-time monitoring of conditions around the glottis, which significantly improves airway safety. Our results suggests that up-down optimized glottic exposure manoeuver may be a useful technique for SaCoVLM™ insertion.Trial registration: ChiCTR, ChiCTR2000028802. Registered 4 January 2020, http://www.chictr.org.cn/ChiCTR2000028802.
Collapse
Affiliation(s)
- Chun-ling Yan
- Department of Anesthesia, Institute of Geriatric Medicine, Beijing Hospital, National Center of Gerontology, Chinese Academy of Medical Sciences, Beijing, People’s Republic of China
| | - Yi-qi-yuan Zhang
- Department of Anesthesia, Institute of Geriatric Medicine, Beijing Hospital, National Center of Gerontology, Chinese Academy of Medical Sciences, Beijing, People’s Republic of China
| | - Ying Chen
- Department of Anesthesia, Institute of Geriatric Medicine, Beijing Hospital, National Center of Gerontology, Chinese Academy of Medical Sciences, Beijing, People’s Republic of China
| | - Zong-yang Qv
- Department of Anesthesia, Institute of Geriatric Medicine, Beijing Hospital, National Center of Gerontology, Chinese Academy of Medical Sciences, Beijing, People’s Republic of China
| | - Ming-zhang Zuo
- Department of Anesthesia, Institute of Geriatric Medicine, Beijing Hospital, National Center of Gerontology, Chinese Academy of Medical Sciences, Beijing, People’s Republic of China
| |
Collapse
|
2
|
Gao Z, Guo Y, Gao X, Wang W, Zhang M, Liu MJ, Chen L, Liu Y, Zhang X, Sun Y, Wang Y. Comparison of a polyvinyl chloride tube with a wire-reinforced tube for tracheal intubation through the SaCoVLM video laryngeal mask airway: protocol for a randomised controlled study. BMJ Open 2022; 12:e066084. [PMID: 36517088 PMCID: PMC9756190 DOI: 10.1136/bmjopen-2022-066084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
INTRODUCTION The SaCoVLM is a new type of video intubating laryngeal mask airway (LMA), and it is the first LMA to realise continuous visual monitoring. There is a lack of studies on intubation using the SaCoVLM. The aim of this study is to compare the success rate of intubation with polyvinyl chloride (PVC) tubes and wire-reinforced (WR) tubes using the SaCoVLM. METHODS AND ANALYSIS This prospective, single-centre, single-blind, parallel-arm, randomised controlled study will be conducted in a tertiary university hospital in China. We will include 104 patients undergoing elective laparoscopic surgery under general anaesthesia. Patients will be randomly assigned to the PVC tracheal tube group (n=52, PVC group) or the WR tracheal tube group (n=52, WR group). The primary outcome is the total success rate of intubation. The secondary outcomes are the first success rate of intubation, the time of tracheal intubation, the site of the first contact, the adjustment action for tracheal intubation, haemodynamic fluctuation during intubation and extubation, incidence of trauma as evidenced by blood, and the incidence rates of postoperative sore throat, hoarseness, and dysphagia. ETHICS AND DISSEMINATION This study was approved by the Ethics Committee of the First Affiliated Hospital of Shandong First Medical University (YXLL-KY-2022 (008)). All participants will provide written informed consent. The results will be disseminated through peer-reviewed publications and at conferences or congresses. TRIAL REGISTRATION NUMBER NCT05338827.
Collapse
Affiliation(s)
- Zhongquan Gao
- Department of Anesthesiology, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Shandong Institute of Anesthesia and Respiratory Critical Medicine, Jinan, China
- Department of Anesthesiology, Shandong First Medical University, Jinan, China
| | - Yongle Guo
- Department of Anesthesiology, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Shandong Institute of Anesthesia and Respiratory Critical Medicine, Jinan, China
- Department of Anesthesiology, Shandong First Medical University, Jinan, China
| | - Xiaojun Gao
- Department of Anesthesiology, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Shandong Institute of Anesthesia and Respiratory Critical Medicine, Jinan, China
| | - Weiwei Wang
- Department of Anesthesiology, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Shandong Institute of Anesthesia and Respiratory Critical Medicine, Jinan, China
| | - Min Zhang
- Department of Anesthesiology, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Shandong Institute of Anesthesia and Respiratory Critical Medicine, Jinan, China
| | - Meng Jie Liu
- Department of Anesthesiology, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Shandong Institute of Anesthesia and Respiratory Critical Medicine, Jinan, China
| | - Lina Chen
- Department of Anesthesiology, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Shandong Institute of Anesthesia and Respiratory Critical Medicine, Jinan, China
| | - Yang Liu
- Department of Anesthesiology, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Shandong Institute of Anesthesia and Respiratory Critical Medicine, Jinan, China
| | - Xiaoning Zhang
- Department of Anesthesiology, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Shandong Institute of Anesthesia and Respiratory Critical Medicine, Jinan, China
| | - Yongtao Sun
- Department of Anesthesiology, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Shandong Institute of Anesthesia and Respiratory Critical Medicine, Jinan, China
| | - Yuelan Wang
- Department of Anesthesiology, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Shandong Institute of Anesthesia and Respiratory Critical Medicine, Jinan, China
- Department of Anesthesiology, Shandong First Medical University, Jinan, China
| |
Collapse
|
3
|
Gómez‐Ríos MÁ, Freire‐Vila E, Casans‐Francés R, Pita‐Fernández S. The Totaltrack
TM
video laryngeal mask: an evaluation in 300 patients. Anaesthesia 2019; 74:751-757. [DOI: 10.1111/anae.14637] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/20/2019] [Indexed: 12/31/2022]
Affiliation(s)
- M. Á. Gómez‐Ríos
- Department of Anaesthesia and Peri‐operative Medicine University Hospital Complex of A Coruña A Coruña Galicia Spain
- Spanish Difficult Airway Group (GEVAD) A CoruñaSpain
| | - E. Freire‐Vila
- Department of Anaesthesia and Peri‐operative Medicine University Hospital Complex of A Coruña A Coruña Galicia Spain
| | - R. Casans‐Francés
- Department of Anaesthesia University Hospital Complex of A Coruña A Coruña Galicia Spain
| | - S. Pita‐Fernández
- Institute for Biomedical Research of A Coruña (INIBIC) Complejo Hospitalario Universitario de A Coruña A Coruña Spain
| |
Collapse
|