1
|
Airtraq Laryngoscope Versus the Conventional Macintosh Laryngoscope During Pediatric Intubation Performed by Nurses: A Randomized Crossover Manikin Study With Three Airway Scenarios. Pediatr Emerg Care 2017; 33:735-739. [PMID: 27228145 DOI: 10.1097/pec.0000000000000741] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES We hypothesized that the Airtraq laryngoscope (Airtraq LLC, Bonita Springs, Fla) is beneficial for intubation of pediatric manikins while performing cardiopulmonary resuscitation (CPR). In the present study, we evaluated the effectiveness of the Macintosh (MAC) laryngoscope (HEINE Optotechnik, Munich, Germany) and Airtraq in 3 simulated CPR scenarios. METHODS A randomized crossover simulation trial was designed. Eighty-three nurses intubated the trachea of a PediaSIM CPR training manikin (FCAE HealthCare, Sarasota, Fla) using the MAC and Airtraq in a normal airway scenario, normal airway with chest compression scenario, and difficult airway with chest compression scenario. The participants were directed to perform a maximum of 3 attempts in each scenario. The success rate, time to intubation, Cormack & Lehane grade, dental compression, and the ease of intubation were measured. RESULTS All participants performed successful intubation with the Airtraq in all 3 scenarios. In all scenarios, the success rate was significantly higher and the time to intubation was significantly shorter with the Airtraq than with the MAC. Glottic visualization using the Cormack-Lehane scale was also better when using Airtraq in all scenarios. CONCLUSIONS In this manikin study, we found that the Airtraq can be used successfully for the intubation of pediatric manikins with normal and difficult airways by medical staff without previous experience in pediatric intubation. Moreover, intubation can be achieved without interrupting chest compression. The use of the Airtraq compared with the MAC led to faster time to intubation. Nevertheless, we recommend that the performance of the Airtraq and the MAC during CPR should be further evaluated in a clinical setting.
Collapse
|
2
|
Cho T, Komasawa N, Haba M, Fujiwara S, Mihara R, Minami T. Needle guides for venous catheter insertion during chest compressions: a crossover simulation trial. Am J Emerg Med 2016; 34:989-92. [DOI: 10.1016/j.ajem.2016.02.036] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2015] [Accepted: 02/12/2016] [Indexed: 11/16/2022] Open
|
3
|
Cho T, Komasawa N, Hattori K, Mihara R, Minami T. Gum-Elastic Bougie Efficacy for Tracheal Intubation During Continuous Chest Compression in Infants-A Crossover Simulation Trial. J Emerg Med 2016; 51:19-24. [PMID: 27133735 DOI: 10.1016/j.jemermed.2016.03.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2016] [Revised: 03/04/2016] [Accepted: 03/06/2016] [Indexed: 10/21/2022]
Abstract
BACKGROUND Recent guidelines for infant cardiopulmonary resuscitation emphasize that all rescuers should minimize interruption of chest compression, even for endotracheal intubation. OBJECTIVE We compared the utility of application of a gum-elastic bougie (GEB) plus Miller laryngoscope (Mil) with the Mil alone during chest compression on an infant mannequin. METHODS Sixteen anesthesiologists with more than 2 years of experience performed tracheal intubation on an infant mannequin using the Mil or Mil plus 6Fr GEB, with or without chest compression. Intubation success rate, intubation time, and subjective difficulty scores of laryngoscopy and tube passage through the glottis were measured. RESULTS In Mil trials, none of the participants failed without compression, whereas four failed with compression (p = 0.03). In Mil-plus-GEB trials, all participants succeeded regardless of chest compression. Intubation time was significantly longer with chest compression in both Mil and Mil-plus-GEB trials (p < 0.001). The intubation time during chest compression was significantly longer in Mil than in Mil-plus-GEB trials (p < 0.001). Difficulty of operation on a visual analog scale (VAS) for laryngoscopy did not significantly differ between Mil and Mil-plus-GEB trials during chest compression, whereas the VAS for tube passage through the glottis was significantly higher in Mil than in Mil-plus-GEB trials. CONCLUSIONS GEB use shortened the intubation time and improved the success rate of infant tracheal intubation during chest compression by anesthesiologists in simulations.
Collapse
Affiliation(s)
- Takashi Cho
- Department of Anesthesiology, Matsushita Memorial Hospital, Osaka, Japan; Department of Anesthesiology, Osaka Medical College, Osaka, Japan
| | | | - Kazuo Hattori
- Department of Anesthesiology, Osaka Medical College, Osaka, Japan
| | - Ryosuke Mihara
- Department of Anesthesiology, Osaka Medical College, Osaka, Japan
| | - Toshiaki Minami
- Department of Anesthesiology, Osaka Medical College, Osaka, Japan
| |
Collapse
|
4
|
Ueno T, Komasawa N, Majima N, Mihara R, Minami T. Tracheal Tube Position Shift During Infant Resuscitation by Chest Compression: A Simulation Comparison by Fixation Method and With or Without Cuff. J Emerg Med 2016; 50:601-6. [PMID: 26823135 DOI: 10.1016/j.jemermed.2015.11.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2015] [Revised: 11/03/2015] [Accepted: 11/20/2015] [Indexed: 11/20/2022]
Abstract
BACKGROUND Tracheal tube placement during infant resuscitation is essential for definite airway protection. Accidental extubation due to tracheal tube displacement is a rare event, but it results in severe complications, especially in infants. OBJECTIVE The present study evaluated how infant tracheal tube displacement is affected by tape vs. tube holder fixation using a manikin. METHODS A tracheal tube with internal diameter of 3.5 mm was placed 10 cm from the gum ridge in an advanced life support (ALS) Baby(®) simulator (Laerdal, Stavanger, Norway). In the first trial, cuff pressure was set at 15, 20, and 25 cmH2O and trials were performed at each setting with no fixation, Durapore(®) (3M, St Paul, MN) tape fixation, Multipore(®) (3M) tape fixation, and Thomas(®) Tube Holder (Laerdal) fixation. After 5 min of chest compression, the tracheal tube shift was measured. In the second trial, we compared the tube shift by chest compression with or without cuff in the same way. RESULTS Relative to no fixation, tracheal tube shift was significantly less in the Durapore, Multipore, and tube holder groups (p < 0.05) at all cuff settings. Of the three fixation methods, the tube holder showed significantly less shift (p < 0.05) relative to tape, regardless of the initial cuff pressure. The positional shift after chest compressions was significantly larger in the trials with cuff than in those without cuff in Durapore or Multipore fixation (p < 0.05), but did not in tube holder fixation. CONCLUSIONS There is less tracheal tube displacement with tube holder fixation than with tape during continuous infant chest compression simulation. The tube cuff can contribute to the positional shift of the tube during infant chest compression.
Collapse
Affiliation(s)
- Takeshi Ueno
- Department of Anesthesiology, Osaka Medical College, Osaka, Japan
| | | | - Nozomi Majima
- Department of Anesthesiology, Osaka Medical College, Osaka, Japan
| | - Ryosuke Mihara
- Department of Anesthesiology, Osaka Medical College, Osaka, Japan
| | - Toshiaki Minami
- Department of Anesthesiology, Osaka Medical College, Osaka, Japan
| |
Collapse
|
5
|
Szarpak L, Truszewski Z, Czyzewski L, Kurowski A, Bogdanski L, Zasko P. Child endotracheal intubation with a Clarus Levitan fiberoptic stylet vs Macintosh laryngoscope during resuscitation performed by paramedics: a randomized crossover manikin trial. Am J Emerg Med 2015; 33:1547-51. [DOI: 10.1016/j.ajem.2015.06.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2015] [Revised: 05/27/2015] [Accepted: 06/02/2015] [Indexed: 10/23/2022] Open
|
6
|
Szarpak L, Karczewska K, Evrin T, Kurowski A, Czyzewski L. Comparison of intubation through the McGrath MAC, GlideScope, AirTraq, and Miller Laryngoscope by paramedics during child CPR: a randomized crossover manikin trial. Am J Emerg Med 2015; 33:946-50. [DOI: 10.1016/j.ajem.2015.04.017] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2015] [Revised: 03/26/2015] [Accepted: 04/08/2015] [Indexed: 10/23/2022] Open
|
7
|
Kido H, Komasawa N, Matsunami S, Kusaka Y, Minami T. Comparison of McGRATH MAC and Macintosh laryngoscopes for double-lumen endotracheal tube intubation by anesthesia residents: a prospective randomized clinical trial. J Clin Anesth 2015; 27:476-80. [PMID: 26111665 DOI: 10.1016/j.jclinane.2015.05.011] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2014] [Revised: 04/21/2015] [Accepted: 05/21/2015] [Indexed: 11/15/2022]
Abstract
STUDY OBJECTIVE This study aimed to compare the utility of McGRATH MAC (McG) and Macintosh (McL) laryngoscopes for double-lumen endotracheal tube intubation in patients undergoing elective surgery. DESIGN Randomized clinical trial. SETTING Operating room. PATIENTS Fifty adult patients scheduled for elective surgery under 1-lung ventilation with American Society of Anesthesiologists physical status 1 to 3. INTERVENTIONS Double-lumen endotracheal tube intubation was performed with the McG (McG group; 25 patients) or conventional McL (McL group; 25 patients) laryngoscope by anesthesia residents. MEASUREMENTS The number of attempts to successful intubation, intubation time, percentage of glottis opening score, and subjective difficulty of laryngoscopy and tube passage through the glottis were assessed. MAIN RESULTS The total numbers of intubation attempts were 1 (McG group, 24 patients; McL group, 16 patients), 2 (McG group, 1 patient; McL group, 8 patients), and 3 (McG group, 0 patient; McL group, 1 patient), with significant differences between the two groups (P = .018). Intubation time was significantly shorter in the McG group compared with the McL group (McG: 17.1 ± 4.6 seconds vs McL: 20.8 ± 5.9 seconds, P = .026). The percentage of glottis opening score was significantly higher in the McG group compared with the McL group (McG: 88.4% ± 13.7% vs McL: 71.4% ± 20.4%, P = .004). CONCLUSIONS The McG demonstrated a better intubation profile compared with the McL, possibly due to its ease of use for double-lumen endotracheal tube intubation. Clinical Trial registry number: UMIN000014636.
Collapse
Affiliation(s)
- Haruki Kido
- Department of Anesthesiology, Osaka Medical College, Daigaku-machi 2-7, Takatsuki, Osaka 569-8686 Japan
| | - Nobuyasu Komasawa
- Department of Anesthesiology, Osaka Medical College, Daigaku-machi 2-7, Takatsuki, Osaka 569-8686 Japan.
| | - Sayuri Matsunami
- Department of Anesthesiology, Osaka Medical College, Daigaku-machi 2-7, Takatsuki, Osaka 569-8686 Japan
| | - Yusuke Kusaka
- Department of Anesthesiology, Osaka Medical College, Daigaku-machi 2-7, Takatsuki, Osaka 569-8686 Japan
| | - Toshiaki Minami
- Department of Anesthesiology, Osaka Medical College, Daigaku-machi 2-7, Takatsuki, Osaka 569-8686 Japan
| |
Collapse
|
8
|
Comparison of Pentax-AWS Airwayscope and Glidescope for Infant Tracheal Intubation by Anesthesiologists during Cardiopulmonary Arrest Simulation: A Randomized Crossover Trial. BIOMED RESEARCH INTERNATIONAL 2015; 2015:190163. [PMID: 26161388 PMCID: PMC4486488 DOI: 10.1155/2015/190163] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/25/2014] [Accepted: 01/06/2015] [Indexed: 11/18/2022]
Abstract
BACKGROUND Recent guidelines for infant cardiopulmonary resuscitation emphasize that all rescuers should minimize interruption of chest compressions, even for endotracheal intubation. We compared the utility of the Pentax-AWS Airwayscope (AWS) with the Glidescope (GS) during chest compressions on an infant manikin. METHODS Twenty-four anesthesiologists with more than two years of experience performed tracheal intubation on an infant manikin using the AWS and GS, with or without chest compressions. RESULTS In GS trials, none of the participants failed without compressions, while three failed with compressions. In AWS trials, all participants succeeded regardless of chest compressions. Intubation time was significantly longer with chest compressions with the GS (P < 0.05), but not with the AWS. Difficulty of operation on a visual analog scale (VAS) for laryngoscopy did not increase significantly with chest compressions with either the GS or the AWS, while the VAS for tube passage through the glottis increased with compressions with the GS, but not with the AWS. CONCLUSION We conclude that in infant simulations managed by anesthesiologists, the AWS performed better than the GS for endotracheal intubation with chest compressions.
Collapse
|
9
|
Szarpak Ł, Karczewska K, Czyżewski Ł, Kurowski A. A randomized comparison of the Laryngoscope with Fiber Optic Reusable Flexible Tip English Macintosh blade to the conventional Macintosh laryngoscope for intubation in simulated easy and difficult child airway with chest compression scenarios. Am J Emerg Med 2015; 33:951-6. [PMID: 25936475 DOI: 10.1016/j.ajem.2015.04.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2015] [Revised: 03/31/2015] [Accepted: 04/08/2015] [Indexed: 11/16/2022] Open
Abstract
INTRODUCTION We hypothesized that the Laryngoscope with Fiber Optic Reusable Flexible Tip English Macintosh blade (TMAC) is beneficial for the intubation of child manikins while performing cardiopulmonary resuscitation (CPR). In the present study, we evaluated the effectiveness of the conventional Macintosh laryngoscope (MAC) and TMAC in 3 simulated CPR scenarios. METHODS A randomized crossover simulation trial was designed. One hundred seven paramedics intubated the trachea of a PediaSIM CPR training manikin (FCAE HealthCare, Sarasota, FL) using the MAC and TMAC in a normal airway scenario (scenario A), normal airway with chest compression scenario (scenario B), and difficult airway with chest compression scenario (scenario C). The participants were directed to make a maximum of 3 attempts in each scenario. The success rate, time required for intubation, Cormack-Lehane grade, dental compression, and the ease of intubation were measured. RESULTS The median time of intubation with MAC and TMAC in scenario A was 19.6 (interquartile range [IQR], 18-23) vs 19 (IQR, 16.2-21.8); in scenario B, 29.5 (IQR, 25-31) vs 26 (IQR, 23.5-29) seconds; and in scenario C, 38 (IQR, 32.5-45) vs 29 (IQR, 25-31) seconds, respectively. The overall efficacy for each of the scenarios was as follows: in scenario A, it was 100% vs 100%; in scenario B, it was 79.4% vs 100% (P = .007); and in scenario C, it was 68.2% vs 90.7% (P < .001), respectively. CONCLUSIONS The TMAC seems to be a superior intubating device compared with the conventional MAC when used in simulated normal and difficult child airway with chest compression scenarios. Future studies should explore the efficacy of TMAC in pediatric clinical emergency settings.
Collapse
Affiliation(s)
- Łukasz Szarpak
- Department of Emergency Medicine, Medical University of Warsaw, Warsaw, Poland
| | - Katarzyna Karczewska
- Anesthesiology and Intensive Care Unit, Mazovian Regional Hospital, Radom, Poland.
| | - Łukasz Czyżewski
- Department of Nephrologic Nursing, Medical University of Warsaw, Warsaw, Poland; Department of Anesthesiology, Cardinal Wyszynski National Institute of Cardiology, Warsaw, Poland
| | - Andrzej Kurowski
- Department of Anesthesiology, Cardinal Wyszynski National Institute of Cardiology, Warsaw, Poland
| |
Collapse
|
10
|
Saraçoğlu A, Bezen O, Şengül T, Uğur EH, Şener S, Yüzer F. Does Video Laryngoscopy Offer Advantages over Direct Laryngoscopy during Cardiopulmonary Resuscitation? Turk J Anaesthesiol Reanim 2015; 43:263-8. [PMID: 27366508 DOI: 10.5152/tjar.2015.52207] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2014] [Accepted: 12/23/2014] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVE Interruption of chest compressions should be minimized because of its negative effects on survival. This randomized, controlled, cross-over study aimed to analyze the effectiveness of Macintosh, Miller, McCoy and McGrath laryngoscopes during with or without chest compressions in the scope of a simulated cardiopulmonary resuscitation scenario. METHODS The time required for successful tracheal intubation, number of attempts, dental trauma severity and the need for optimization manoeuvres were recorded during cardiopulmonary resuscitation with and without chest compressions. The experience with computer games during the last 10 years were asked to the participants and recorded. RESULTS McCoy laryngoscope yielded the shortest time for successful tracheal intubation both in the presence of and without chest compressions. During the use of McCoy laryngoscopes, fewer tracheal intubation attempts, lower incidence of dental trauma and lower visual analogue scale scores on the ease of intubation were recorded. Participants who are experienced computer game players using Macintosh, McCoy and McGrath achieved successful tracheal intubation in a significantly shorter time during resuscitation without chest compressions. Dental trauma incidence and number of tracheal intubation attempts did not show any significant difference between the four laryngoscopes being related to the rate of playing computer games. CONCLUSION McGrath video laryngoscopes do not appear to have advantages over direct laryngoscopes for securing a smooth and successful tracheal intubation during rhythmic chest compressions. We believe that as McCoy laryngoscope provided tracheal intubation in a shorter time and with fewer attempts, this laryngoscope may increase the success rate of resuscitation.
Collapse
Affiliation(s)
- Ayten Saraçoğlu
- Department of Anaesthesiology, Bilim University Faculty of Medicine, İstanbul, Turkey
| | - Olgaç Bezen
- Health Services Vocational High School, Bilim University, İstanbul, Turkey
| | - Türker Şengül
- Department of Anaesthesiology, Bilim University Faculty of Medicine, İstanbul, Turkey
| | - Egin Hüsnü Uğur
- Department of Anaesthesiology, Bilim University Faculty of Medicine, İstanbul, Turkey
| | - Sibel Şener
- Health Services Vocational High School, Bilim University, İstanbul, Turkey
| | - Fisun Yüzer
- Department of Anaesthesiology, Bilim University Faculty of Medicine, İstanbul, Turkey
| |
Collapse
|
11
|
Rodríguez-Núñez A, Moure-González J, Rodríguez-Blanco S, Oulego-Erroz I, Rodríguez-Rivas P, Cortiñas-Díaz J. Tracheal intubation of pediatric manikins during ongoing chest compressions. Does Glidescope® videolaryngoscope improve pediatric residents' performance? Eur J Pediatr 2014; 173:1387-90. [PMID: 24797698 DOI: 10.1007/s00431-014-2329-z] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2014] [Revised: 04/23/2014] [Accepted: 04/24/2014] [Indexed: 11/30/2022]
Abstract
UNLABELLED Our objective was to test the ability of pediatric residents to intubate the trachea of infant and child manikins during continuous chest compressions (CC) by means of indirect videolaryngoscopy with Glidescope® versus standard direct laryngoscopy. A randomized crossover simulation trial was designed. Twenty-three residents trained to intubate child and infant manikins were eligible for the study. They were asked to perform tracheal intubation in manikins assisted by both standard laryngoscopy and Glidescope® while a colleague delivered uninterrupted chest compressions. In the infant cardiac arrest scenario, the median (IQR) total time for intubation was significantly shorter with the Miller laryngoscope [28.2 s (20.4-34.4)] than with Glidescope® [38.0 s (25.3-50.5)] (p = 0.021). The number of participants who needed more than 30 s to intubate the manikin was also significantly higher with Glidescope® (n = 13) than with the Miller laryngoscope (n = 7, p = 0.01). In the child scenario, the total time for intubation and number of intubation failures were similar with Macintosh and Glidescope® laryngoscopes. The participants' subjective difficulty of the procedure was similar for direct and videolaryngoscopy. CONCLUSION In simulated infant and child cardiac arrest scenarios, pediatric residents are able to intubate the trachea during CC. The videolaryngoscope Glidescope® does not improve performance in this setting.
Collapse
Affiliation(s)
- Antonio Rodríguez-Núñez
- Pediatric Emergency and Critical Care Division, Pediatric Area, Hospital Clinico Universitario de Santiago de Compostela, Galicia's Public Health System (SERGAS), A Choupana, s/n, Santiago de Compostela, Spain,
| | | | | | | | | | | |
Collapse
|
12
|
Komasawa N, Ueki R, Yamamoto N, Nishi SI, Kaminoh Y, Tashiro C. Comparison of Pentax-AWS Airwayscope, Airtraq and Miller laryngoscope for tracheal intubation by novice doctors during infant cardiopulmonary resuscitation simulation: a randomized crossover trial. J Anesth 2013; 27:778-80. [PMID: 23568017 DOI: 10.1007/s00540-013-1607-7] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2013] [Accepted: 03/25/2013] [Indexed: 11/28/2022]
Abstract
Recent guidelines for infant cardiopulmonary resuscitation emphasize that all rescuers should minimize interruption of chest compressions, even for endotracheal intubation. We compared the utility of the Pentax-AWS Airway Scope (AWS) with an infant-sized Intlock (AWS-I), Airtraq laryngoscope (ATQ) and Miller laryngoscope during chest compressions on an infant manikin. Twenty-three novice doctors performed tracheal intubation on an infant manikin using the AWS-I, ATQ and Miller laryngoscope, with or without chest compressions. In Miller laryngoscope trials, one participant failed to secure the airway without chest compressions, while nine failed with compressions (P < 0.05). In ATQ trials, none of the participants failed without compressions, while six failed with compressions (P < 0.05). In AWS-I trials, all participants succeeded regardless of chest compressions. Intubation time was significantly longer with chest compressions with the Miller laryngoscope and ATQ, but not with the AWS-I. The AWS-I is an effective device for endotracheal intubation during chest compressions in infant simulations managed by novice doctors.
Collapse
Affiliation(s)
- Nobuyasu Komasawa
- Department of Anesthesiology, Hyogo College of Medicine, Mukogawa-cho 1-1, Nishinomiya, Hyogo, 663-8501, Japan,
| | | | | | | | | | | |
Collapse
|
13
|
Tampo A, Suzuki A, Fujita S, Sako S, Iwasaki H, Kunisawa T. A reply. Anaesthesia 2012. [DOI: 10.1111/anae.12010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
14
|
Tampo A, Suzuki A, Sako S, Kunisawa T, Iwasaki H, Fujita S. A comparison of the Pentax Airway Scope™ with the Airtraq™ in an infant manikin. Anaesthesia 2012; 67:881-4. [PMID: 22506698 DOI: 10.1111/j.1365-2044.2012.07153.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We compared the Pentax Airway Scope(TM) with the Airtraq(TM) optical laryngoscope in an infant manikin. Twenty-three anaesthetists randomly performed tracheal intubation: at rest, (a) with the Airway Scope and (b) with the Airtraq; and during chest compressions, (c) with the Airway Scope and (d) with the Airtraq. The success rate, modified Cormack and Lehane classification for glottic view, time taken to view the glottis, and time to place the tracheal tube were recorded. There was no difference in intubation success rate or quality of glottic view between the two devices. The median (IQR [range]) time taken to obtain a view of the glottis was 4.5 (3.7-6.4 [1.8-14.0]) s using the Airway Scope compared with 7.1 (5.5-9.6 [3.3-12.0]) s using the Airtraq (p = 0.001), and to successful placement of the tracheal tube was 8.3 (6.8-9.4 [3.7-20.7]) s using the Airway Scope compared with 11.2 (10.4-13.8 [4.9-23.7]) s using the Airtraq (p = 0.001). During chest compressions, the median (IQR [range]) time taken to view the glottis was 5.1 (4.0-7.2 [2.0-12.4]) s using the Airway Scope compared with 7.5 (5.0-13.2 [4.2-26.4]) s using the Airtraq (p = 0.006), and to successful placement of the tracheal tube was 9.5 (6.6-13.7 [4.5-16.2]) s using the Airway Scope compared with 11.7 (9.1-18.1 [6.2-37.4]) s using the Airtraq (p = 0.022). We conclude that both devices provided good quality views of the glottis and successful tracheal intubation in an infant manikin both at rest and during external chest compressions. Use of the Airway Scope resulted in a shorter time to view the glottis and perform successful tracheal intubation compared with the Airtraq.
Collapse
Affiliation(s)
- A Tampo
- Department of Emergency Medicine, Asahikawa Medical University Hospital, Asahikawa, Japan.
| | | | | | | | | | | |
Collapse
|
15
|
Kohama H, Komasawa N, Ueki R, Itani M, Nishi SI, Kaminoh Y. Addition of a video camera system improves the ease of Airtraq® tracheal intubation during chest compression. J Anesth 2011; 26:296-8. [DOI: 10.1007/s00540-011-1301-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2011] [Accepted: 11/28/2011] [Indexed: 10/14/2022]
|
16
|
Komasawa N, Ueki R, Yamamoto N, Atagi K, Nishi SI, Kaminoh Y, Tashiro C. Comparison of air-Q(®) and Soft Seal(®) laryngeal mask for airway management by novice doctors during infant chest compression: a manikin study. Resuscitation 2011; 83:365-8. [PMID: 21958927 DOI: 10.1016/j.resuscitation.2011.08.025] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2011] [Revised: 08/13/2011] [Accepted: 08/19/2011] [Indexed: 10/17/2022]
Abstract
BACKGROUND Recent resuscitation guidelines for infant cardiopulmonary resuscitation (CPR) emphasise that rescuers should minimise the interruption of chest compressions. To that end, supraglottic devices such as laryngeal mask airways (LMAs) are suggested as a backup for airway management during infant CPR. We therefore compared the utility of the air-Q(®) LMA (air-Q) with that of the Soft Seal(®) LMA (Soft Seal) for infant CPR in an infant manikin. METHODS Twenty-four novice doctors in the anaesthesia department performed insertion and ventilation with air-Q and Soft Seal on an infant manikin with or without chest compression. RESULTS Two doctors failed to insert the Soft Seal without chest compression, while nine failed during chest compression (P<0.05). However, only one doctor failed to insert the air-Q without chest compression, and two doctors failed during chest compression. Insertion time was not significantly increased with chest compression using either device. Insertion time during chest compression was significantly shorter for the air-Q than for the Soft Seal (P<0.05). The visual analogue scale (VAS) was used to evaluate difficulty of use (0mm (extremely easy) to 100mm (extremely difficult)). VAS scores did not change significantly by the addition of chest compression with either device; however, VAS scores during chest compression were significantly higher with Soft Seal than with the air-Q device. CONCLUSION We conclude that novice doctors find the air-Q easier to use than Soft Seal for emergency airway management during chest compression in infants, in an infant manikin.
Collapse
Affiliation(s)
- Nobuyasu Komasawa
- Department of Anesthesiology, Hyogo College of Medicine, Mukogawa-cho 1-1, Nishinomiya, Hyogo 663-8501, Japan.
| | | | | | | | | | | | | |
Collapse
|
17
|
Komasawa N, Atagi K, Ueki R, Nishi SI, Kaminoh Y, Tashiro C. Reply to Letter: Is Airtraq® optical laryngoscope a high-efficiency device for emergent tracheal intubation during infant chest compression? Resuscitation 2011. [DOI: 10.1016/j.resuscitation.2011.05.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
18
|
Xue F, Liu J, Liao X, Yuan Y, Wang Q. Is Airtraq® optical laryngoscope a high-efficiency device for emergent tracheal intubation during infant chest compression? Resuscitation 2011; 82:1246-7; author reply 1247. [DOI: 10.1016/j.resuscitation.2011.04.030] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2011] [Accepted: 04/07/2011] [Indexed: 12/01/2022]
|