1
|
Colella M, Zanin A, Toumazi A, Bourmaud A, Boizeau P, Guilmin-Crepon S, Leick N, Khat S, Alison M, Baud O, Biran V. Association between Portal Vein Thrombosis after Umbilical Vein Catheterization and Neonatal Asphyxia. Neonatology 2024:1-7. [PMID: 38522417 DOI: 10.1159/000537902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 02/12/2024] [Indexed: 03/26/2024]
Abstract
INTRODUCTION Neonatal portal vein thrombosis (PVT) is frequently related to umbilical venous catheterization (UVC), but risk factors remain unclear. This study aims to analyze the variables associated to PVT in near- to full-term newborns with UVC, with a focus on newborns exposed to controlled therapeutic hypothermia (CTH) for hypoxic ischemic encephalopathy (HIE). METHODS This is retrospective cohort study of infants delivered at or after 36 weeks and with a birthweight over 1,500 g. All infants were assessed for UVC location and PVT using ultrasonography performed between day 5 and day 10 after catheterization. RESULTS Among 213 eligible patients, PVT was diagnosed in 57 (27%); among them, 54 (95%) were localized in the left portal vein branch. With all significant factors in univariate analysis considered, higher gestational age at birth (adjusted OR 1.35; 95% CI: 1.12-1.64, p = 0.002) and duration of UVC placement (adjusted OR 1.36; 95% CI: 1.11-1.67, p = 0.004) were the main risk factors of PVT. Among 87 infants who were cooled for HIE, 31 (36%) had PVT compared to 26 (21%) in infants without CTH. Using a multivariate model including variables linked to treatment procedures only, an increased PVT incidence was statistically associated with UVC duration (adjusted OR 1.33; 95% CI: 1.08; 1.63, p = 0.01) and CTH (adjusted OR 1.94; 95% CI: 1.04-3.65, p = 0.04). CONCLUSION Left PVT was frequently observed in near- to full-term neonates with UVC. Among factors linked to treatment procedures, both duration of UVC and CTH exposure for HIE were found to be independent risk factors of PVT.
Collapse
Affiliation(s)
- Marina Colella
- Neonatal Intensive Care Unit, Assistance Publique-Hôpitaux de Paris, Robert Debré Children's Hospital, University Paris Cité, Paris, France
- I2D2, Inserm 1141, University Paris Cité, Paris, France
| | - Anna Zanin
- Neonatal Intensive Care Unit, Assistance Publique-Hôpitaux de Paris, Robert Debré Children's Hospital, University Paris Cité, Paris, France
- Pediatric Intensive Care Unit, San Bortolo Hospital, Vicenza, Italy
| | - Artemis Toumazi
- Unit of Clinical Epidemiology, Assistance Publique-Hôpitaux de Paris, Robert Debré Children's Hospital, University Paris Cité, Inserm U1123 and CIC-EC 1426, Paris, France
| | - Aurélie Bourmaud
- Unit of Clinical Epidemiology, Assistance Publique-Hôpitaux de Paris, Robert Debré Children's Hospital, University Paris Cité, Inserm U1123 and CIC-EC 1426, Paris, France
| | - Priscilla Boizeau
- Unit of Clinical Epidemiology, Assistance Publique-Hôpitaux de Paris, Robert Debré Children's Hospital, University Paris Cité, Inserm U1123 and CIC-EC 1426, Paris, France
| | - Sophie Guilmin-Crepon
- Unit of Clinical Epidemiology, Assistance Publique-Hôpitaux de Paris, Robert Debré Children's Hospital, University Paris Cité, Inserm U1123 and CIC-EC 1426, Paris, France
| | - Noémie Leick
- Neonatal Intensive Care Unit, Assistance Publique-Hôpitaux de Paris, Robert Debré Children's Hospital, University Paris Cité, Paris, France
| | - Sophea Khat
- Neonatal Intensive Care Unit, Assistance Publique-Hôpitaux de Paris, Robert Debré Children's Hospital, University Paris Cité, Paris, France
| | - Marianne Alison
- I2D2, Inserm 1141, University Paris Cité, Paris, France
- Department of Radiology, Assistance Publique-Hôpitaux de Paris, Robert Debré Children's Hospital, University Paris Cité, Paris, France
| | - Olivier Baud
- I2D2, Inserm 1141, University Paris Cité, Paris, France
- Division of Neonatology and Pediatric Intensive Care, Children's University Hospital and University of Geneva, Geneva, Switzerland
| | - Valerie Biran
- Neonatal Intensive Care Unit, Assistance Publique-Hôpitaux de Paris, Robert Debré Children's Hospital, University Paris Cité, Paris, France
- I2D2, Inserm 1141, University Paris Cité, Paris, France
| |
Collapse
|
2
|
Yamamoto T, Iijima S. Umbilical Vein Calcification Associated with Double-Lumen Catheter Malpositioning in an Extremely Low-Birth-Weight Infant. Pediatr Rep 2024; 16:69-76. [PMID: 38251316 PMCID: PMC10801626 DOI: 10.3390/pediatric16010007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 11/28/2023] [Accepted: 01/10/2024] [Indexed: 01/23/2024] Open
Abstract
Umbilical venous (UV) catheters (UVCs) are commonly used in severely ill neonates. Complications associated with UVC often result from an inappropriate UVC position. Calcification of the UV, a rare complication, was observed in an extremely low-birth-weight infant born at 23 weeks of gestation. After birth, the infant experienced respiratory and circulatory dysfunction, followed by disseminated intravascular coagulation (DIC). A UVC was inserted, and circulatory agonists and blood transfusions were administered, as well as a calcium gluconate infusion for hypocalcemia and hyperkalemia. Ten days after birth, calcification was detected in the UV, likely due to a tunica intima injury caused by UVC, a hypercoagulable state due to DIC, and a high-dose calcium gluconate infusion. Additionally, proximal port malpositioning of the double-lumen catheter might have contributed to calcification within the UV. To prevent such complications, real-time ultrasound confirmation with agitated saline contrast during UVC placement is recommended; in the absence of the facility or skills for ultrasonography, X-rays should be performed in the lateral and anteroposterior views. Furthermore, when using multi-lumen catheters, physicians should not only verify the tip position but also ensure proper placement of proximal ports and carefully select medications administered through the ports.
Collapse
Affiliation(s)
- Takuya Yamamoto
- Department of Pediatrics, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu 431-3192, Japan;
| | - Shigeo Iijima
- Department of Regional Neonatal-Perinatal Medicine, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu 431-3192, Japan
| |
Collapse
|
3
|
Perme T. Central Lines and Their Complications in Neonates: A Case Report and Literature Review. CHILDREN (BASEL, SWITZERLAND) 2023; 11:26. [PMID: 38255340 PMCID: PMC10814986 DOI: 10.3390/children11010026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 12/22/2023] [Accepted: 12/24/2023] [Indexed: 01/24/2024]
Abstract
Central lines are essential devices in NICUs, used primarily in preterm neonates and critically ill term neonates. They are typically divided into non-tunnelled, tunnelled and totally implanted. In light of the increasing use of central lines in the NICU setting, monitoring of the risk factors associated with complications has to be an important part of neonatal care quality management. Presented here is a case of a preterm neonate with cardiac tamponade caused by UVC tip migration. Among complications of central lines are CLABSI, with an incidence of 3 to 21 per 1000 catheter days, and portal vein thrombosis, which is common but probably under-recognised, whereas other mechanical complications such as pericardial and pleural effusions are rare, with an incidence of less than 1%. Complications can cause injury to the neonates, as well as increase the costs of health services because of increases in the length of stay in the NICU. It is recommended that the catheter tip location is confirmed either by X-ray or ultrasonography. In order to minimise the risk of CLABSI, the use of bundles is recommended. Certain recommendations need to be followed when using different types of catheters. Future research is aimed at novel ways of central line securement to minimise mechanical complications and the use of antimicrobial catheters to reduce the rate of CLABSI.
Collapse
Affiliation(s)
- Tina Perme
- Neonatal Intensive Care Unit, Department for Perinatology, Division of Gynaecology and Obstetrics, University Medical Centre Ljubljana, 1000 Ljubljana, Slovenia
| |
Collapse
|
4
|
Cao J, Zhang Y, Yin Y, Liu Y. Accuracy of chest radiography compared to ultrasound for positioning the umbilical venous catheter in neonates: A meta-analysis and systematic review. J Vasc Access 2023; 24:1051-1060. [PMID: 34784827 DOI: 10.1177/11297298211046755] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
This study was aimed to investigate the accuracy of anteroposterior chest radiography for tip position verification for the umbilical venous catheters in neonates compared to ultrasound. A search in the PubMed, Embase, the Cochrane Library, and EBSCO was conducted to evaluate all the related articles on umbilical venous catheter (UVC), ultrasound AND neonates updated to August, 2020. Study selection, data extraction, and quality assessment were performed independently by two investigators. Random effects model was used to estimate the pooled sensitivity, specificity, and diagnostic odds ratio (DOR). The summary receiver operator characteristic (SROC) curve was constructed, and the area under the SROC curve (AUC) was calculated. Fourteen related studies were finally included for meta-analysis. The overall diagnostic sensitivity and specificity of X-ray on tip verification of UVC were 0.90 (95% CI 0.71-0.97) and 0.82 (95% CI 0.53-0.95), respectively. The pooled DOR was 3.69 (95% CI 1.64-5.71). The AUC was 0.93 (95% CI 0.90-0.95). The meta-regression analysis suggested that study sample size, study design, different US confirming method, and different gold standard in original design might be potential sources of heterogeneity. Our conclusion is that the commonly used anteroposterior X-ray is not reliable in identifying the exact anatomical location of UVC tip in neonates. Studies suggested ultrasound or echocardiography with saline contrast injection could be the gold standard for verification of catheter location and should be considered whenever possible, especially in premature patients. More studies are needed to expand the use of ultrasound or echocardiography in tip position confirming of UVCs.
Collapse
Affiliation(s)
- Juan Cao
- Affiliated Hospital of Weifang Medical University, Weifang, China
| | - Yuzheng Zhang
- Affiliated Hospital of Weifang Medical University, Weifang, China
| | - Yanling Yin
- School of Nurinsg, Weifang Medical University, Weifang, China
| | - Yuxiu Liu
- School of Nurinsg, Weifang Medical University, Weifang, China
| |
Collapse
|
5
|
D'Andrea V, Prontera G, Pinna G, Cota F, Fattore S, Costa S, Migliorato M, Barone G, Pittiruti M, Vento G. Securement of Umbilical Venous Catheter Using Cyanoacrylate Glue: A Randomized Controlled Trial. J Pediatr 2023; 260:113517. [PMID: 37244573 DOI: 10.1016/j.jpeds.2023.113517] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Revised: 04/24/2023] [Accepted: 05/21/2023] [Indexed: 05/29/2023]
Abstract
OBJECTIVE To evaluate the role of cyanoacrylate glue in reducing dislodgement of umbilical venous catheters (UVCs). STUDY DESIGN This was a single-center, randomized, controlled, nonblinded trial. All infants requiring an UVC according to our local policy were included in the study. Infants with a UVC with a centrally located tip as verified by real-time ultrasound examination were eligible for the study. Primary outcome was the safety and efficacy of securement by cyanoacrylate glue plus cord-anchored suture (SG group) vs securement by suture alone (S group), as measured by reduction in dislodgment of the external tract of the catheter. Secondary outcomes were tip migration, catheter-related bloodstream infection, and catheter-related thrombosis. RESULTS In the first 48 hours after UVC insertion, dislodgement was significantly higher in the S group than in the SG group (23.1% vs 1.5%; P < .001). The overall dislodgement rate was 24.6% in the S group vs 7.7% in the SG group (P = .016). No differences were found in catheter-related bloodstream infection and catheter-related thrombosis. The incidence of tip migration was similar in both groups (S group 12.2% vs SG group 11.7%). CONCLUSIONS In our single-center study, cyanoacrylate glue was safe and effective for securement of UVCs, and particularly effective in decreasing early catheter dislodgments. TRIAL REGISTRATION UMIN-CTR Clinical Trial; Registration number: R000045844.
Collapse
Affiliation(s)
- Vito D'Andrea
- Neonatology Unit, Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Rome, Italy.
| | - Giorgia Prontera
- Neonatology Unit, Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Rome, Italy
| | - Giovanni Pinna
- Neonatal Intensive Care Unit, Maternal-Fetal Department, "S. Camillo-Forlanini" Hospital, Rome, Italy
| | - Francesco Cota
- Neonatology Unit, Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Rome, Italy
| | - Simona Fattore
- Neonatology Unit, Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Rome, Italy
| | - Simonetta Costa
- Neonatology Unit, Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Rome, Italy
| | - Martina Migliorato
- Neonatology Unit, Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Rome, Italy
| | - Giovanni Barone
- Neonatal Intensive Care Unit, Infermi Hospital, Rimini, AUSL Romagna, Rimini, Italy
| | - Mauro Pittiruti
- Department of Surgery, Fondazione Policlinico Gemelli, Rome, Italy
| | - Giovanni Vento
- Neonatology Unit, Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Rome, Italy
| |
Collapse
|
6
|
Kowalczyk A(O, Bhogal J, Surak A. Point-of-care ultrasound aided diagnosis and management of peritoneal parenteral nutrition extravasation in a preterm baby: A case report. Clin Case Rep 2023; 11:e7563. [PMID: 37415581 PMCID: PMC10320363 DOI: 10.1002/ccr3.7563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2023] [Revised: 05/19/2023] [Accepted: 05/23/2023] [Indexed: 07/08/2023] Open
Abstract
POCUS could identify some of UVC complications at the bedside. It complements the clinical picture and helps narrowing the deferential diagnosis when there is a clinical deterioration.
Collapse
Affiliation(s)
| | - Jagmeet Bhogal
- Department of PaediatricsUniversity of AlbertaEdmontonAlbertaCanada
| | - Aimann Surak
- Department of PaediatricsUniversity of AlbertaEdmontonAlbertaCanada
| |
Collapse
|
7
|
Kim MJ, Yoo SY, Jeon TY, Kim JH, Kim YJ. Imaging of Umbilical Venous Catheter-Related Hepatic Complications in Neonates. JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY 2023; 84:586-595. [PMID: 37324991 PMCID: PMC10265250 DOI: 10.3348/jksr.2022.0056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
An umbilical venous catheter (UVC) is commonly placed for central venous access in preterm or critically ill full-term neonates to provide total parenteral nutrition (TPN) and medication. However, UVCs can result in complications, including infection, portal vein thrombosis, and hepatic tissue injury. The inadvertent administration of hypertonic fluid through a malpositioned UVC can also cause hepatic parenchymal damage with mass-like fluid collection that simulates a tumorous condition during imaging. Ultrasonography and radiographic examinations play an essential role in detecting UVC-related complications. This pictorial essay aims to present the imaging findings of UVC-related hepatic complications in neonates.
Collapse
|
8
|
Stewart DL, Elsayed Y, Fraga MV, Coley BD, Annam A, Milla SS. Use of Point-of-Care Ultrasonography in the NICU for Diagnostic and Procedural Purposes. Pediatrics 2022; 150:190110. [PMID: 37154781 DOI: 10.1542/peds.2022-060053] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 09/26/2022] [Indexed: 11/29/2022] Open
Abstract
Point-of-care ultrasonography (POCUS) refers to the use of portable imaging performed by the provider clinician at the bedside for diagnostic, therapeutic, and procedural purposes. POCUS could be considered an extension of the physical examination but not a substitute for diagnostic imaging. Use of POCUS in emergency situations can be lifesaving in the NICU if performed in a timely fashion for cardiac tamponade, pleural effusions, pneumothorax, etc, with potential for enhancing quality of care and improving outcomes.
In the past 2 decades, POCUS has gained significant acceptance in clinical medicine in many parts of the world and in many subspecialties. Formal accredited training and certification programs are available for neonatology trainees as well as for many other subspecialties in Canada, Australia, and New Zealand. Although no formal training program or certification is available to neonatologists in Europe, POCUS is widely available to providers in NICUs. A formal institutional POCUS fellowship is now available in Canada. In the United States, many clinicians have the skills to perform POCUS and have incorporated it in their daily clinical practice. However, appropriate equipment remains limited, and many barriers exist to POCUS program implementation.
Recently, the first international evidence-based POCUS guidelines for use in neonatology and pediatric critical care were published. Considering the potential benefits, a recent national survey of neonatologists confirmed that the majority of clinicians were inclined to adopt POCUS in their clinical practice if the barriers could be resolved.
This technical report describes many potential POCUS applications in the NICU for diagnostic and procedural purposes.
Collapse
Affiliation(s)
- Dan L Stewart
- Department of Pediatrics and International Pediatrics, Norton Children's Neonatology Affiliated with University of Louisville School of Medicine, Louisville, Kentucky
| | - Yasser Elsayed
- Department of Pediatrics and Child Health, Max Rady College of Medicine, University of Manitoba-Canada, Health Sciences Centre-Winnipeg, Winnipeg, Manitoba, Canada
| | - María V Fraga
- Department of Pediatrics, Perelman School of Medicine, University of Pennsylvania, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania
| | - Brian D Coley
- Departments of Radiology and Pediatrics, University of Cincinnati College of Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio
| | - Aparna Annam
- Departments of Radiology and Pediatrics, University of Colorado School of Medicine, Children's Hospital Colorado, Vascular Anomalies Center, Aurora, Colorado
| | - Sarah Sarvis Milla
- Departments of Radiology and Pediatrics, University of Colorado School of Medicine, Children's Hospital Colorado, Aurora, Colorado
| |
Collapse
|
9
|
Kaur A, Manerkar S, Patra S, Kalamdani P, Kalathingal T, Mondkar J. Ultrasound-Guided Umbilical Venous Catheter Insertion to Reduce Rate of Catheter Tip Malposition in Neonates: A Randomized, Controlled Trial. Indian J Pediatr 2022; 89:1093-1098. [PMID: 35881217 DOI: 10.1007/s12098-022-04295-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Accepted: 05/26/2022] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To investigate whether ultrasound-guided umbilical venous catheter (UVC) insertion (US group) reduced the rate of malpositioning of the catheter tip compared to the standard method of insertion (SD group). METHODS In this open-label, randomized, controlled trial, neonates admitted to NICU within the first week of life were randomly assigned to the US group (n = 26) or SD group (n = 27). Neonates with major congenital anomalies of the thorax and abdomen were excluded. The primary outcome was the rate of malpositioning of the catheter tip. RESULTS The rate of malpositioning of the catheter tip was observed in a significantly lower number of neonates in the US group as compared to the SD group (11/26, 42.3% vs. 20/27, 74%; RR = 0.57, 95% CI: 0.34 to 0.94, p = 0.019). As more of the UVCs were positioned optimally in the first attempt in the US group than SD group, the need for repeated attempts at catheter repositioning was reduced, resulting in reduced procedure time (minutes) [mean (SD), 23.96 (6.42) vs. 30 (1.83); mean difference 6.04 (95% CI: 3.46 to 8.62), p = 0.005]. This also led to a reduction in the additional X-ray exposure in the US group (n = 11) compared to the SD group (n = 20) [95% CI: 3.12 to 44.26; p = 0.020]. CONCLUSION Ultrasound-guided UVC insertion significantly reduced the rate of catheter tip malposition. It also reduced the number of attempts at catheter manipulation, procedure time, and X-ray exposures. With adequate training, it could be incorporated into routine bedside practice during UVC insertion for optimum placement. TRIAL REGISTRATION Clinical Trial Registry of India ( www.ctri.nic.in ) CTRI/2021/03/031894.
Collapse
Affiliation(s)
- Amandeep Kaur
- Department of Neonatology, Lokmanya Tilak Municipal Medical College and General Hospital, Sion, Mumbai, Maharashtra, 400022, India
| | - Swati Manerkar
- Department of Neonatology, Lokmanya Tilak Municipal Medical College and General Hospital, Sion, Mumbai, Maharashtra, 400022, India.
| | - Saikat Patra
- Department of Neonatology, Lokmanya Tilak Municipal Medical College and General Hospital, Sion, Mumbai, Maharashtra, 400022, India
| | - Pavan Kalamdani
- Department of Neonatology, Lokmanya Tilak Municipal Medical College and General Hospital, Sion, Mumbai, Maharashtra, 400022, India
| | - Thaslima Kalathingal
- Department of Neonatology, Lokmanya Tilak Municipal Medical College and General Hospital, Sion, Mumbai, Maharashtra, 400022, India
| | - Jayashree Mondkar
- Department of Neonatology, Lokmanya Tilak Municipal Medical College and General Hospital, Sion, Mumbai, Maharashtra, 400022, India
| |
Collapse
|
10
|
Real-Time Ultrasound Guidance for Umbilical Venous Cannulation in Neonates With Congenital Heart Disease. Pediatr Crit Care Med 2022; 23:e257-e266. [PMID: 35250003 DOI: 10.1097/pcc.0000000000002919] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES Umbilical venous cannulation is the favored approach to perinatal central access worldwide but has a failure rate of 25-50% and the insertion technique has not evolved in decades. Improving the success of this procedure would have broad implications, particularly where peripherally inserted central catheters are not easily obtained and in neonates with congenital heart disease, in whom umbilical access facilitates administration of inotropes and blood products while sparing vessels essential for later cardiac interventions. We sought to use real-time, point-of-care ultrasound to achieve central umbilical venous access in patients for whom conventional, blind placement techniques had failed. DESIGN Multicenter case series, March 2019-May 2021. SETTING Cardiac and neonatal ICUs at three tertiary care children's hospitals. PATIENTS We identified 32 neonates with congenital heart disease, who had failed umbilical venous cannulation using traditional, blind techniques. INTERVENTIONS Real-time ultrasound guidance and liver pressure were used to replace malpositioned catheters and achieve successful placement at the inferior cavoatrial junction. MEASUREMENTS AND MAIN RESULTS In 32 patients with failed prior umbilical venous catheter placement, real-time ultrasound guidance was used to successfully "rescue" the line and achieve central position in 23 (72%). Twenty of 25 attempts (80%) performed in the first 48 hours of life were successful, and three of seven attempts (43%) performed later. Twenty-four patients (75%) were on prostaglandin infusion at the time of the procedure. We did not identify an association between patient weight or gestational age and successful placement. CONCLUSIONS Ultrasound guidance has become standard of care for percutaneous central venous access but is a new and emerging technique for umbilical vessel catheterization. In this early experience, we report that point-of-care ultrasound, together with liver pressure, can be used to markedly improve success of placement. This represents a significant advance in this core neonatal procedure.
Collapse
|
11
|
Manea C, Pryce R, Ramadan G. Fifteen-minute consultation: Is this umbilical venous catheter safe to use? Arch Dis Child Educ Pract Ed 2022; 108:173-180. [PMID: 35101937 DOI: 10.1136/archdischild-2019-317388] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Accepted: 12/10/2021] [Indexed: 11/03/2022]
Abstract
Umbilical venous catheters are widely used in neonatal practice, therefore promoting safe use of such catheters to reduce complications remains a healthcare priority. This report will equip the reader with essential knowledge for successful catheter insertion and maintenance, which is key to better outcomes. Recent advances in safe localisation of catheter tip and the development of a red flag system will enhance the clinician's ability to predict potential complications related to these catheters as they remain in situ.
Collapse
Affiliation(s)
- Cristina Manea
- Oliver Fisher Neonatal Unit, Medway NHS Foundation Trust, Gillingham, UK
| | - Russell Pryce
- Trevor Mann Baby Unit, Royal Sussex County Hospital, Brighton, UK
| | - Ghada Ramadan
- Oliver Fisher Neonatal Unit, Medway NHS Foundation Trust, Gillingham, UK
| |
Collapse
|
12
|
Bersani I, Piersigilli F, Iacona G, Savarese I, Campi F, Dotta A, Auriti C, Di Stasio E, Garcovich M. Incidence of umbilical vein catheter-associated thrombosis of the portal system: A systematic review and meta-analysis. World J Hepatol 2021; 13:1802-1815. [PMID: 34904047 PMCID: PMC8637679 DOI: 10.4254/wjh.v13.i11.1802] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2021] [Revised: 08/31/2021] [Accepted: 10/14/2021] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND The use of umbilical venous catheters (UVCs) in the perinatal period may be associated with severe complications, including the occurrence of portal vein thrombosis (PVT).
AIM To assess the incidence of UVC-related PVT in infants with postnatal age up to three months.
METHODS A systematic and comprehensive database searching (PubMed, Cochrane Library, Scopus, Web of Science) was performed for studies from 1980 to 2020 (the search was last updated on November 28, 2020). We included in the final analyses all peer-reviewed prospective cohort studies, retrospective cohort studies and case-control studies. The reference lists of included articles were hand-searched to identify additional studies of interest. Studies were considered eligible when they included infants with postnatal age up to three months with UVC-associated PVT. Incidence estimates were pooled by using random effects meta-analyses. The quality of included studies was assessed using the Newcastle-Ottawa scale. The systematic review was performed according to the Preferred Reporting Items for Systematic reviews and Meta-Analysis (PRISMA) guidelines.
RESULTS Overall, 16 studies were considered eligible and included in the final analyses. The data confirmed the relevant risk of UVC-related thrombosis. The mean pooled incidence of such condition was 12%, although it varied across studies (0%-49%). In 15/16 studies (94%), diagnosis of thrombosis was made accidentally during routine screening controls, whilst in 1/16 study (6%) targeted imaging assessments were carried out in neonates with clinical concerns for a thrombus. Tip position was investigated by abdominal ultrasound (US) alone in 1/16 (6%) studies, by a combination of radiography and abdominal US in 14/16 (88%) studies and by a combination of radiography, abdominal US and echocardiography in 1/16 (6%) studies.
CONCLUSION To the best of our knowledge, this is the first systematic review specifically investigating the incidence of UVC-related PVT. The use of UVCs requires a high index of suspicion, because its use is significantly associated with PVT. Well-designed prospective studies are required to assess the optimal approach to prevent UVC-related thrombosis of the portal system.
Collapse
Affiliation(s)
- Iliana Bersani
- Medical and Surgical Neonatology, Bambino Gesù Children's Hospital, Rome 00165, Italy
| | - Fiammetta Piersigilli
- Department of Neonatology, Cliniques Universitaires Saint Luc, Universitè Catholique de Louvain, Bruxelles 1200, Belgium
| | - Giulia Iacona
- Faculty of Medicine, Imperial College London, London SW7 2AZ, United Kingdom
| | - Immacolata Savarese
- Medical and Surgical Neonatology, Bambino Gesù Children's Hospital, Rome 00165, Italy
| | - Francesca Campi
- Medical and Surgical Neonatology, Bambino Gesù Children's Hospital, Rome 00165, Italy
| | - Andrea Dotta
- Medical and Surgical Neonatology, Bambino Gesù Children's Hospital, Rome 00165, Italy
| | - Cinzia Auriti
- Medical and Surgical Neonatology, Bambino Gesù Children's Hospital, Rome 00165, Italy
| | - Enrico Di Stasio
- Department of Biochemistry and Clinical Biochemistry, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Università Cattolica del Sacro Cuore, Roma 00168, Italy
| | - Matteo Garcovich
- CEMAD Digestive Disease Center, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome 00168, Italy
- CEMAD Digestive Disease Center, Università Cattolica del Sacro Cuore, Rome 00168, Italy
| |
Collapse
|
13
|
Schwaberger B, Schlatzer C, Freidorfer D, Bruckner M, Wolfsberger CH, Mileder LP, Pichler G, Urlesberger B. The Use of a Disposable Umbilical Clamp to Secure an Umbilical Venous Catheter in Neonatal Emergencies—An Experimental Feasibility Study. CHILDREN 2021; 8:children8121093. [PMID: 34943289 PMCID: PMC8699894 DOI: 10.3390/children8121093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 11/21/2021] [Accepted: 11/24/2021] [Indexed: 11/16/2022]
Abstract
Recent guidelines recommend the umbilical venous catheter (UVC) as the optimal vascular access method during neonatal resuscitation. In emergencies the UVC securement may be challenging and time-consuming. This experimental study was designed to test the feasibility of new concepts for the UVC securement. Umbilical cord remnants were catheterized with peripheral catheters and secured with disposable umbilical clamps. Three different securement techniques were investigated. Secure 1: the disposable umbilical clamp was closed at the level of the inserted catheter. Secure 2: the clamp was closed at the junction of the catheter and plastic wings. Secure 3: the setting of Secure 2 was combined with an umbilical tape. The main outcomes were the feasibility of fluid administration and the maximum force to release the securement. This study shows that inserting peripheral catheters into the umbilical vein and securing them with disposable umbilical clamps is feasible. Rates of lumen obstruction and the effectiveness of the securement were superior with Secure 2 and 3 compared to Secure 1. This new approach may be a rewarding option for umbilical venous catheterization and securement particularly in low-resource settings and for staff with limited experience in neonatal emergencies. However, although promising, these results need to be confirmed in clinical trials before being introduced into clinical practice.
Collapse
Affiliation(s)
- Bernhard Schwaberger
- Division of Neonatology, Department of Pediatrics and Adolescent Medicine, Medical University of Graz, 8036 Graz, Austria; (C.S.); (M.B.); (C.H.W.); (L.P.M.); (G.P.); (B.U.)
- Medizinercorps Graz, Austrian Red Cross Federal Association Styria, 8010 Graz, Austria;
- Correspondence: ; Tel.: +43-316-3853-0018
| | - Christoph Schlatzer
- Division of Neonatology, Department of Pediatrics and Adolescent Medicine, Medical University of Graz, 8036 Graz, Austria; (C.S.); (M.B.); (C.H.W.); (L.P.M.); (G.P.); (B.U.)
| | - Daniel Freidorfer
- Medizinercorps Graz, Austrian Red Cross Federal Association Styria, 8010 Graz, Austria;
| | - Marlies Bruckner
- Division of Neonatology, Department of Pediatrics and Adolescent Medicine, Medical University of Graz, 8036 Graz, Austria; (C.S.); (M.B.); (C.H.W.); (L.P.M.); (G.P.); (B.U.)
| | - Christina H. Wolfsberger
- Division of Neonatology, Department of Pediatrics and Adolescent Medicine, Medical University of Graz, 8036 Graz, Austria; (C.S.); (M.B.); (C.H.W.); (L.P.M.); (G.P.); (B.U.)
| | - Lukas P. Mileder
- Division of Neonatology, Department of Pediatrics and Adolescent Medicine, Medical University of Graz, 8036 Graz, Austria; (C.S.); (M.B.); (C.H.W.); (L.P.M.); (G.P.); (B.U.)
| | - Gerhard Pichler
- Division of Neonatology, Department of Pediatrics and Adolescent Medicine, Medical University of Graz, 8036 Graz, Austria; (C.S.); (M.B.); (C.H.W.); (L.P.M.); (G.P.); (B.U.)
| | - Berndt Urlesberger
- Division of Neonatology, Department of Pediatrics and Adolescent Medicine, Medical University of Graz, 8036 Graz, Austria; (C.S.); (M.B.); (C.H.W.); (L.P.M.); (G.P.); (B.U.)
| |
Collapse
|
14
|
Gibson K, Sharp R, Ullman A, Morris S, Kleidon T, Esterman A. Adverse events associated with umbilical catheters: a systematic review and meta-analysis. J Perinatol 2021; 41:2505-2512. [PMID: 34272469 DOI: 10.1038/s41372-021-01147-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 06/11/2021] [Accepted: 06/30/2021] [Indexed: 02/06/2023]
Abstract
OBJECTIVE To determine the incidence of adverse events (AEs) associated with umbilical catheters in the neonatal population. STUDY DESIGN Systematic review and meta-analysis of observational studies and randomized controlled trials published between 2010 and 2020. RESULTS In total 14,226 umbilical venous catheters (UVCs) and 4228 umbilical arterial catheters (UACs) were included. Overall, 13.4% of UVCs were associated with an AE (95% CI: 10.1-17.0) or 2.4 per 1000 catheter days (95% CI: 1.8-3.0). UACs had an AE rate of 9% (95% CI: 5.9-12.8) or 0.87 per 1000 catheter days (95% CI: 0.4-1.3). UVC malposition was the most common (41.7% [95% CI: 27.6-56.5]). Local injury from UAC taping was the most common AE in one study. CONCLUSIONS Umbilical catheters have a high incidence of AEs. Research into accurate methods of tip verification, tip surveillance, and securement is required.
Collapse
Affiliation(s)
- Kim Gibson
- Clinical and Health Sciences, Rosemary Bryant AO Research Centre, University of South Australia, Adelaide, SA, Australia.
| | - Rebecca Sharp
- Clinical and Health Sciences, Rosemary Bryant AO Research Centre, University of South Australia, Adelaide, SA, Australia
| | - Amanda Ullman
- Children's Health Queensland and Health Service, Centre of Children's Health Research, South Brisbane, QLD, Australia.,School of Nursing, Midwifery and Social Work, The University of Queensland, Brisbane, QLD, Australia
| | - Scott Morris
- Neonatal Unit, Flinders Medical Centre, Bedford Park, SA, Australia.,College of Medicine and Public Health, Flinders University, Adelaide, Australia
| | - Tricia Kleidon
- Queensland Children's Hospital, South Brisbane, QLD, Australia
| | - Adrian Esterman
- Clinical and Health Sciences, Rosemary Bryant AO Research Centre, University of South Australia, Adelaide, SA, Australia
| |
Collapse
|
15
|
Acun C, Baker A, Brown LS, Iglesia KA, Sisman J. Peripherally inserted central cathether migration in neonates: Incidence, timing and risk factors. J Neonatal Perinatal Med 2021; 14:411-417. [PMID: 33459671 DOI: 10.3233/npm-200684] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
BACKGROUND PICC line use is a common practice in neonatal units, but it is associated with various complications. Catheter migration is the most common complication in neonates. Periodic imaging is recommended to monitor the tip position of the PICCs, but the optimal frequency is undetermined. The incidence, timing and risk factors that are associated with PICC migration have not been fully investigated beyond 24 hrs in neonates. The aim of the study was to determine the incidence, timing and risk factors that are associated with peripherally inserted central venous catheter (PICC) migration in neonates. METHODS This was a single center, retrospective study of 168 PICCs placed in 141 neonates in the neonatal intensive care unit (NICU) between 2015 and 2016. The incidence of catheter migration was determined radiographically at 12-24 hrs and every third day after insertion until it was removed. RESULTS Overall incidence of PICC migration was 28%and most commonly was detected within the first three days after PICC placement (83%). The incidence of PICC migration was higher in males. The PICC migration was associated with difficulty advancing the PICC at the time of insertion and PICC dressing change. CONCLUSION Serial evaluation of PICC placement in neonates is required to maintain proper position. Based on our experience in our unit, we recommend periodic imaging at 12-24 hrs and on the third day after PICC placement as most migration occurred within three days after insertion.
Collapse
Affiliation(s)
- C Acun
- Pediatrics, Cleveland Clinic Children's Hospital, Cleveland, OH, USA
| | - A Baker
- THR Dallas Hospital, Dallas, TX, USA
| | - L S Brown
- Health System Research, Parkland Health and Hospital System, Dallas, TX, USA
| | - K A Iglesia
- Pediatric Radiology, Cook Children's Hospital, Fort Worth, TX, USA
| | - J Sisman
- Pediatrics, UTSW, Dallas, TX, USA
| |
Collapse
|
16
|
Kurepa D, Boyar V, Zaghloul N, Beachy J, Zaytseva A, Teng D, Cooper R, Klewer S, Amodio J. Structured Neonatal Point-of-Care Ultrasound Training Program. Am J Perinatol 2021; 38:e284-e291. [PMID: 32344442 DOI: 10.1055/s-0040-1709667] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
OBJECTIVE Point-of-care ultrasound (POC US) has been increasingly used by intensive care physicians. Growing use of POC US necessitates defining distinct clinical indications for its application, as well as structured POC US training programs. Homogeneous approach to POC US education combined with rigorous quality assurance should further enable POC US to become standard-of-care clinical tool. This study aimed to present the first, innovative, and structured POC US program in neonatal-perinatal medicine field. In addition, we reviewed the availability of the POC US training programs across different medical specialties. STUDY DESIGN Available English-language publications on POC US training programs in general and neonatal-perinatal medicine were reviewed in this study. DISCUSSION Mounting body of evidence suggests improved procedural completion rates, as well as clinical decision making with the use of POC US. However, limited research supported the existence of structured, comprehensive POC US programs. It was recognized that medical institutions need to develop syllabuses, teach, and credential increasing number of health care professionals in the use of POC US. We defined intuitive educational strategy that encompasses POC US clinical indications, educational curriculum, scanning protocols, competence evaluation, and finally credentialing process. In addition, we offered description of the imaging quality assurance, as well as POC US coding, and reimbursement. CONCLUSION Future efforts need to be dedicated to the ongoing development of neonatal POC US as a clinical instrument. It should allow for eventual paradigm change and improved effectiveness in management of critically ill neonates.
Collapse
Affiliation(s)
- Dalibor Kurepa
- Division of Neonatal-Perinatal Medicine, Department of Pediatrics, Cohen Children's Medical Center, New Hyde Park, New York
| | - Vitalya Boyar
- Division of Neonatal-Perinatal Medicine, Department of Pediatrics, Cohen Children's Medical Center, New Hyde Park, New York
| | - Nahla Zaghloul
- Division of Neonatal-Perinatal Medicine, Department of Pediatrics, University of Arizona, Tucson, Arizona
| | - Joanna Beachy
- Division of Neonatal-Perinatal Medicine, Department of Pediatrics, Cohen Children's Medical Center, New Hyde Park, New York
| | - Alla Zaytseva
- Division of Neonatal-Perinatal Medicine, Department of Pediatrics, Cohen Children's Medical Center, New Hyde Park, New York
| | - David Teng
- Division of Emergency Medicine, Department of Pediatrics, Cohen Children's Medical Center, New Hyde Park, New York
| | - Rubin Cooper
- Division of Cardiology, Department of Pediatrics, Cohen Children's Medical Center, New Hyde Park, New York
| | - Scott Klewer
- Division of Cardiology, Department of Pediatrics, University of Arizona, Tucson, Arizona
| | - John Amodio
- Division of Radiology, Department of Pediatrics, Cohen Children's Medical Center, New Hyde Park, New York
| |
Collapse
|
17
|
Upadhyay J, Basu S, Srivastava Y, Digal KC, Shubham S, Grover R, Singh P. Agitated saline contrast to delineate central venous catheter position in neonates. J Perinatol 2021; 41:1638-1644. [PMID: 32728038 DOI: 10.1038/s41372-020-0761-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 07/11/2020] [Accepted: 07/22/2020] [Indexed: 01/04/2023]
Abstract
OBJECTIVE Central venous catheter (CVC) insertion is required for the management of sick neonates. Ultrasonography/targeted neonatal echocardiography (TNE) with/without normal saline (NS) flush is used to identify CVC position. The present study compared the visibility and safety of agitated saline (AS) with normal saline (NS) flush. STUDY DESIGN This prospective interventional study included 110 CVC insertions, both umbilical venous catheterization (UVC) and peripherally inserted central catheterization (PICC). Catheter position was monitored by real-time TNE. RESULTS Overall visibility of catheter tip (combined UVC and PICC) was significantly better in AS (n = 55) compared with NS group (n = 55) [48/55 (87.2%) vs. 28/55 (50.9%); p < 0.0001]. Time to detect catheter tip by AS push was significantly less than that of NS push. There was no difference in the amount of saline flush required with either method. No major adverse effect was observed. CONCLUSIONS AS push can be used as a safe method to delineate CVC position in neonates.
Collapse
Affiliation(s)
- Jaya Upadhyay
- Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, India
| | - Sriparna Basu
- Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, India.
| | - Yash Srivastava
- Division of Cardiology, Department of Pediatrics, All India Institute of Medical Sciences, Rishikesh, India
| | - Kanhu Charan Digal
- Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, India
| | - Shantanu Shubham
- Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, India
| | - Rajat Grover
- Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, India
| | - Poonam Singh
- Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, India
| |
Collapse
|
18
|
Gibson K, Sharp R, Ullman A, Morris S, Kleidon T, Esterman A. Risk factors for umbilical vascular catheter-related adverse events: A scoping review. Aust Crit Care 2021; 35:89-101. [PMID: 34088575 DOI: 10.1016/j.aucc.2021.02.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 02/24/2021] [Accepted: 02/28/2021] [Indexed: 02/07/2023] Open
Abstract
INTRODUCTION Adverse events associated with umbilical catheters include malposition, bloodstream infections, thrombosis, tip migration, and extravasation, resulting in loss of vascular access and increased risk of morbidity and mortality. There is a need for greater understanding of risk factors associated with adverse events to inform safe practice. OBJECTIVES The aim of the study was to summarise the existing evidence regarding risk factors for umbilical catheter-related adverse events to inform the undertaking of future research. REVIEW METHOD USED A scoping review of peer-reviewed original research and theses was performed. DATA SOURCES The US National Library of Medicine National Institutes of Health, Embase, EMcare, and ProQuest Dissertations and Theses were the data sources. REVIEW METHODS Informed by the Joanna Briggs Institute Reviewer's Manual, all types of original research studies reporting adverse events published in English from 2009 to 2020 were eligible for inclusion. Studies where umbilical artery catheter and umbilical venous catheter data could not be extracted separately were excluded. RESULTS Searching identified 1954 publications and theses, 1533 were excluded at screening, and 418 were assessed for eligibility at full text. A total of 89 studies met the inclusion criteria. A range of potential risk factors for umbilical arterial and venous catheters were identified. Longer dwell time and prematurity were associated with increased risk of bloodstream infection and thrombosis in cohort studies. Case studies detailed analogous factors such as insertion techniques and lack of catheter surveillance during dwell warrant further investigation. CONCLUSIONS We identified a vast range of patient, device, and provider risk factors that warrant further investigation. There was a lack of large cohort studies and randomised controlled trials to demonstrate the significance of these risk factors. Improvement in methods to ensure correct catheter tip location and to detect adverse events early is essential. In addition, policy needs to be developed to guide clinicians in catheter surveillance measures to reduce the risk of adverse events.
Collapse
Affiliation(s)
- Kim Gibson
- Clinical and Health Sciences, University of South Australia, PO Box 2471, South Australia, 5000, Australia.
| | - Rebecca Sharp
- Clinical and Health Sciences, University of South Australia, PO Box 2471, South Australia, 5000, Australia.
| | - Amanda Ullman
- School of Nursing and Midwifery, Menzies Health Institute Queensland, Nathan Campus, 170 Kessels Road Queensland 4111, Australia; Children's Health Queensland and Health Service Centre of Children's Health Research, South Brisbane QLD 4101, Australia; School of Nursing, Midwifery and Social Work The University of Queensland, Brisbane QLD 4072, Australia.
| | - Scott Morris
- College of Medicine and Public Health, Flinders University, Neonatal Unit, Flinders Medical Centre, Bedford Drive, Bedford Park, South Australia 5042, Australia.
| | - Tricia Kleidon
- Queensland Children's Hospital, 401 Stanley Street, South Brisbane, Q. 4101, Australia; School of Nursing and Midwifery, Griffith University, 170 Kessels Raod, Nathan, Q. 4111, Australia.
| | - Adrian Esterman
- Clinical and Health Sciences, University of South Australia, PO Box 2471, South Australia, 5000, Australia.
| |
Collapse
|
19
|
Barone G, Pittiruti M, Biasucci DG, Elisei D, Iacobone E, La Greca A, Zito Marinosci G, D'Andrea V. Neo-ECHOTIP: A structured protocol for ultrasound-based tip navigation and tip location during placement of central venous access devices in neonates. J Vasc Access 2021; 23:679-688. [PMID: 33818191 DOI: 10.1177/11297298211007703] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Central venous access devices are often needed in neonates admitted to Neonatal Intensive Care Unit. The location of the tip of the central catheter is usually assessed by post-procedural X-ray. However, this strategy is inaccurate and time consuming. Recent guidelines strongly recommend intra-procedural methods of tip location, to increase the cost-effectiveness of the maneuver and to shorten the time between device placement and utilization. In this regard, real-time ultrasound represents the most promising tool for tip navigation and location in neonates. The aim of this paper is (a) to review all the evidence available about ultrasound-based tip navigation and tip location of central catheters in the neonatal population (b) to propose a novel protocol for tip navigation and location (Neo-ECHOTIP) based on such evidence.
Collapse
Affiliation(s)
- Giovanni Barone
- Neonatal Intensive Care Unit, Ospedale Infermi di Rimini, AUSL della Romagna, Rimini, Italy
| | - Mauro Pittiruti
- Department of Surgery, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Rome, Italy
| | - Daniele G Biasucci
- Department of Anesthesia and Intensive Care, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Rome, Italy
| | - Daniele Elisei
- Department of Intensive Care and Anesthesia, Central Hospital, Macerata, Italy
| | - Emanuele Iacobone
- Department of Intensive Care and Anesthesia, Central Hospital, Macerata, Italy
| | - Antonio La Greca
- Department of Surgery, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Rome, Italy
| | - Geremia Zito Marinosci
- UOC di Rianimazione e Neuroanestesia, Azienda Ospedaliera di Rilievo Nazionale Santobono-Pausilipon, Neaples, Italy
| | - Vito D'Andrea
- Neonatal Intensive Care Unit, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Rome, Italy
| |
Collapse
|
20
|
Implementing point of care ultrasound in the neonatal intensive care unit: a safety study. J Perinatol 2021; 41:879-884. [PMID: 33603105 DOI: 10.1038/s41372-021-00955-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 12/14/2020] [Accepted: 01/21/2021] [Indexed: 11/08/2022]
Abstract
OBJECTIVE Point of care ultrasound (POCUS) use is increasing in pediatrics and has been demonstrated to be superior in identifying central catheter tip location in neonatal intensive care units. However, limited data exist regarding cardiorespiratory changes secondary to POCUS in neonates. STUDY DESIGN A prospective observational equivalence study was performed on 50 POCUS assessments of central catheter tip location in 46 patients ≥23 weeks gestation. Heart rate (HR), respiratory rate (RR), and percent oxygen saturation (SpO2) levels were collected before and after POCUS. Limits of equivalence were set in advance. RESULT Equivalence was demonstrated in HR, RR, and SpO2 before and after POCUS. HR decreased by 3.24 beats per minute (90% CI: -5.36, -1.14). RR increased by 0.71 breath/min (90% CI: -1.84, +3.27). SpO2 increased by 0.54 percentage points (90% CI: -0.23, +1.31). CONCLUSION Identifying central catheter tip location using POCUS in neonates appears safe without affecting cardiorespiratory stability.
Collapse
|
21
|
Rubortone SA, Costa S, Perri A, D'Andrea V, Vento G, Barone G. Real-time ultrasound for tip location of umbilical venous catheter in neonates: a pre/post intervention study. Ital J Pediatr 2021; 47:68. [PMID: 33736669 PMCID: PMC7977571 DOI: 10.1186/s13052-021-01014-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2020] [Accepted: 02/26/2021] [Indexed: 12/18/2022] Open
Abstract
BACKGROUND Recent guidelines advocate the use of real-time ultrasound to locate umbilical venous catheter tip. So far, training programs are not well established. METHODS A pre/post interventional study was carried out in our tertiary neonatal intensive care unit centre to evaluate the efficacy of a training protocol in the use of real-time ultrasound. Primary outcome was the percentage in the use of real-time ultrasound. RESULTS Fifty-four patients were enrolled. The use of real-time ultrasound for tip location significantly increased after the training program (15.3% vs 89.2%, p < 0.0001). After the training the tip of the catheters was more frequently placed at the junction of the inferior vena cava and right atrium (75% vs 30.7%, p = 0.0023). Twenty-two catheters were also evaluated with serial scans during the intervention phase to assess migration rate which was 50%. CONCLUSION a multimodal, targeted training on the use of real-time ultrasound for umbilical venous catheter placement is feasible. Real-time ultrasound is easily teachable, increases the number of umbilical venous catheters placed in a correct position, reduces the number of line manipulations and the need of chest-x-rays.
Collapse
Affiliation(s)
- Serena Antonia Rubortone
- Department of Woman and Child Health and Public Health, Division of Neonatology, University Hospital Fondazione Policlinico Gemelli IRCCS, Rome, Italy.
| | - Simonetta Costa
- Department of Woman and Child Health and Public Health, Division of Neonatology, University Hospital Fondazione Policlinico Gemelli IRCCS, Rome, Italy
| | - Alessandro Perri
- Department of Woman and Child Health and Public Health, Division of Neonatology, University Hospital Fondazione Policlinico Gemelli IRCCS, Rome, Italy
| | - Vito D'Andrea
- Department of Woman and Child Health and Public Health, Division of Neonatology, University Hospital Fondazione Policlinico Gemelli IRCCS, Rome, Italy
| | - Giovanni Vento
- Department of Woman and Child Health and Public Health, Division of Neonatology, University Hospital Fondazione Policlinico Gemelli IRCCS, Rome, Italy
| | - Giovanni Barone
- Neonatal Intensive Care Unit, Infermi Hospital, Rimini, AUSL of Romagna, Italy
| |
Collapse
|
22
|
Shabeer MP, Abiramalatha T, Gibikote S, Rebekah G, Thomas N. Bedside sonography performed by neonatology residents to confirm central vascular catheter position in neonates - A Prospective Diagnostic Evaluation study. J Neonatal Perinatal Med 2021; 14:101-107. [PMID: 32310193 DOI: 10.3233/npm-200409] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
OBJECTIVE To evaluate the diagnostic accuracy and utility of bedside ultrasound (US) by neonatology residents to confirm position of umbilical venous catheter (UVC), umbilical arterial catheter (UAC), and peripherally inserted central catheter (PICC). METHODS In this prospective study, we included neonates who required UVC, UAC or PICC insertion. Two neonatology residents performed all bedside US examinations after a short period of training. Plain radiograph was taken as gold standard. Time taken for confirmation of catheter position by US and radiograph was recorded. RESULTS We recruited 71 neonates for UVC and UAC, and 40 neonates for PICC. Sensitivity and specificity of US in identifying a malpositioned catheter was good for UVC (94% and 66.7% respectively) and UAC (86.7% and 94.5%). Agreement between radiograph and US was good for UVC [0.718 (0.512, 0.861); p < 0.001] and UAC [0.857 (0.682, 0.953); p < 0.001]. Sensitivity (47.8%) of US in identifying a malpositioned PICC was low, though specificity (82.4%) was good. Agreement between radiograph and US in identifying PICC position was poor [0.25 (-0.084, 0.545); p 0.024]. This was due to incorrect interpretation of catheter position on radiograph in some infants, which was confirmed by the radiologist. The median time taken for US was significantly less than time taken for radiograph in confirming the position of UVC (50 vs. 155 minutes; p < 0.001)), UAC (45 vs. 128 minutes; p < 0.001), and PICC (60 vs. 136 minutes; p < 0.001). CONCLUSION US examination byneonatology residents has good diagnostic accuracy in confirming the position of UAC and UVC, and possibly PICC in neonates. The time taken to confirm catheter position by US is significantly less than radiograph.
Collapse
Affiliation(s)
- M P Shabeer
- Department of Neonatology, Christian Medical College, Vellore, Tamil Nadu, India
| | - T Abiramalatha
- Department of Neonatology, Christian Medical College, Vellore, Tamil Nadu, India.,Department of Neonatology, Sri Ramachandra Institute of Higher Education and Research (SRIHER), Chennai, India
| | - S Gibikote
- Department of Radiology, Christian Medical College, Vellore, Tamil Nadu, India
| | - G Rebekah
- Department of Biostatistics, Christian Medical College, Vellore, Tamil Nadu, India
| | - N Thomas
- Department of Neonatology, Christian Medical College, Vellore, Tamil Nadu, India
| |
Collapse
|
23
|
D'Andrea V, Prontera G, Rubortone SA, Pezza L, Pinna G, Barone G, Pittiruti M, Vento G. Umbilical Venous Catheter Update: A Narrative Review Including Ultrasound and Training. Front Pediatr 2021; 9:774705. [PMID: 35174113 PMCID: PMC8841780 DOI: 10.3389/fped.2021.774705] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2021] [Accepted: 12/20/2021] [Indexed: 12/30/2022] Open
Abstract
The umbilical venous catheter (UVC) is one of the most commonly used central lines in neonates. It can be easily inserted soon after birth providing stable intravenous access in infants requiring advanced resuscitation in the delivery room or needing medications, fluids, and parenteral nutrition during the 1st days of life. Resident training is crucial for UVC placement. The use of simulators allows trainees to gain practical experience and confidence in performing the procedure without risks for patients. UVCs are easy to insert, however when the procedure is performed without the use of ultrasound, there is a quite high risk, up to 40%, of non-central position. Ultrasound-guided UVC tip location is a simple and learnable technique and therefore should be widespread among all physicians. The feasibility of targeted training on the use of point-of-care ultrasound (POCUS) for UVC placement in the neonatal intensive care unit (NICU) among neonatal medical staff has been demonstrated. Conversely, UVC-related complications are very common and can sometimes be life-threatening. Despite UVCs being used by neonatologists for over 60 years, there are still no standard guidelines for assessment or monitoring of tip location, securement, management, or dwell time. This review article is an overview of the current knowledge and evidence available in the literature about UVCs. Our aim is to provide precise and updated recommendations on the use of this central line.
Collapse
Affiliation(s)
- Vito D'Andrea
- Division of Neonatology, Department of Woman and Child Health and Public Health, University Hospital Fondazione Policlinico Gemelli Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Rome, Italy
| | - Giorgia Prontera
- Division of Neonatology, Department of Woman and Child Health and Public Health, University Hospital Fondazione Policlinico Gemelli Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Rome, Italy
| | - Serena Antonia Rubortone
- Division of Neonatology, Department of Woman and Child Health and Public Health, University Hospital Fondazione Policlinico Gemelli Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Rome, Italy
| | - Lucilla Pezza
- Division of Neonatology, Department of Woman and Child Health and Public Health, University Hospital Fondazione Policlinico Gemelli Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Rome, Italy
| | - Giovanni Pinna
- Division of Neonatology, Department of Woman and Child Health and Public Health, University Hospital Fondazione Policlinico Gemelli Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Rome, Italy
| | - Giovanni Barone
- Neonatal Intensive Care Unit, Infermi Hospital, Rimini, Italy
| | - Mauro Pittiruti
- Department of Surgery, University Hospital Fondazione Policlinico Gemelli Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Rome, Italy
| | - Giovanni Vento
- Division of Neonatology, Department of Woman and Child Health and Public Health, University Hospital Fondazione Policlinico Gemelli Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Rome, Italy
| |
Collapse
|
24
|
Sobczak A, Dudzik A, Kruczek P, Kwinta P. Ultrasound Monitoring of Umbilical Catheters in the Neonatal Intensive Care Unit-A Prospective Observational Study. Front Pediatr 2021; 9:665214. [PMID: 33996700 PMCID: PMC8119780 DOI: 10.3389/fped.2021.665214] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Accepted: 04/12/2021] [Indexed: 01/22/2023] Open
Abstract
Introduction: Umbilical catheterization provides a quick yet demanding central line that can lead to complications seen nowhere else. The aim of our study was to determine whether the repeated ultrasound scanning can influence the catheterization time, prevent some of the catheter-related complications, support the decision-making process and allow prolonged catheterization in patients without an alternative central access route. Methods: A prospective observational study was performed in a tertiary neonatal intensive care unit. A total of 129 patients and 194 umbilical catheters (119 venous and 75 arterial) were analyzed with a total of 954 scans. Ultrasound screening consisted of 1) assessing the catheter tip, location, movability, and surface and 2) analyzing the catheter trajectory. The outcome variables were defined as 1) catheter dislocation and 2) associated thrombosis. Results: Dislocation of catheter throughout the whole catheterization period was observed in 68% (81/119) of UVCs and 23% (17/75) of UACs. Thrombotic complications were observed in 34.5% (41/119) of UVCs and 12% (9/75) of UACs. 1/3 of UAC-associated thrombi were visible only after catheter removal. 51% (61/119) of UVC patients and 8% (6/75) of UAC patients made a clinical decision regarding the obtained catheter image. Conclusion: Bedside ultrasound imaging of catheters supports the decision-making process related to the catheterization duration, shortening the time if abnormalities are detected and allowing a safer prolonged UC stay when an alternative central line cannot be inserted.
Collapse
Affiliation(s)
- Alina Sobczak
- Neonatal Intensive Care Unit, Department of Pediatrics, Jagiellonian University Medical College, Kraków, Poland
| | - Aleksandra Dudzik
- Neonatal Intensive Care Unit, Department of Pediatrics, Jagiellonian University Medical College, Kraków, Poland
| | - Piotr Kruczek
- Neonatal Intensive Care Unit, Department of Pediatrics, Jagiellonian University Medical College, Kraków, Poland
| | - Przemko Kwinta
- Neonatal Intensive Care Unit, Department of Pediatrics, Jagiellonian University Medical College, Kraków, Poland
| |
Collapse
|
25
|
Akar S. Intraperitoneal extravasation of total parenteral nutrition: A rare but life-threatening complication of umbilical vein catheter, two case reports. J Clin Neonatol 2021. [DOI: 10.4103/jcn.jcn_163_20] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
26
|
Use of Point of Care Ultrasound for Confirming Central Line Tip Position in Neonates. Indian Pediatr 2020. [DOI: 10.1007/s13312-020-1957-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
27
|
Neonatal Nurse Practitioner Use of Ultrasonography to Verify Umbilical Venous Catheter Placement in the Neonatal Intensive Care Unit. Adv Neonatal Care 2020; 20:294-300. [PMID: 32735412 DOI: 10.1097/anc.0000000000000708] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
BACKGROUND Literature dating back to 1982 supports the use of ultrasound to confirm UVC position as a more reliable method compared to x-ray. The use of ultrasound to confirm UVC position remains infrequent in the NICU. PURPOSE To determine the feasibility of training an NNP in the acquisition and interpretation of a parasternal short-axis (PSAX) image of the heart to confirm UVC position. METHODS A retrospective review of 48 charts evaluated descriptive data using standard technique of an x-ray to confirm UVC placement. An NNP was trained to acquire and interpret a parasternal short-axis (PSAX) cardiac view by a pediatric cardiologist. The NNP independently and prospectively evaluated 21 neonates and determined whether the UVC was in satisfactory or unsatisfactory position. The same image was blindly over-read by the pediatric cardiologist. Agreement between the NNP and pediatric cardiologist interpretations as well as the pediatric cardiologist and radiologist interpretations was evaluated using the κ-test. RESULTS Initial pediatric cardiology interpretation of UVC position showed the UVC to be malpositioned in 66% of neonates (n = 14). NNP and pediatric cardiology interpretations in UVC position had 86% agreement (κ-0.667). Pediatric cardiology (ultrasound) and radiology interpretations (x-ray) in UVC position had 86% agreement (κ-0.69). IMPLICATIONS FOR PRACTICE It is feasible to train NNPs to perform and accurately interpret a single PSAX ultrasound image to determine satisfactory UVC position. IMPLICATIONS FOR RESEARCH Increasing the use of ultrasound to determine satisfactory position of UVCs in the NICU can reduce unnecessary exposure to ionizing radiation in neonates.
Collapse
|
28
|
Wu L, Peng M, Cao T, Yang Y, Wang Q, Luo K, Chen P. Application of a modified electrocardiogram-guided technique for umbilical venous catheterisation in neonates: A retrospective trial. J Paediatr Child Health 2020; 56:716-720. [PMID: 31849129 DOI: 10.1111/jpc.14710] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/24/2019] [Revised: 10/15/2019] [Accepted: 11/03/2019] [Indexed: 11/28/2022]
Abstract
AIM To investigate the effectiveness and safety of modified electrocardiogram (ECG)-guided technique in umbilical venous catheterisation in neonates. METHODS Sixty-six critically ill neonates underwent umbilical venous catheterisation with (ECG group) or without (control group) ECG guidance from January 2017 to March 2019. We retrospectively analysed and compared the rate of correct tip placement on first try, unplanned extubation rate and incidence of catheter-related complications between the two groups. RESULTS There were 33 patients in each group. The ECG group showed significantly higher rate of correct tip placement on first try (P < 0.001), lower unplanned extubation rate (P < 0.001), but identical incidence of catheter-related complications (P = 0.492) comparing with the control group. CONCLUSION The ECG-guided technique is an effective and safe method for umbilical venous catheterisation. The connecting method we modified made this technique more practical and can be promoted to areas without access to specific ECG adaptors.
Collapse
Affiliation(s)
- Liyuan Wu
- Division of Neonatology, Department of Pediatrics, The Second Xiangya Hospital, Central South University, Changsha, China.,Clinical Nursing Teaching and Research Section, The Second Xiangya Hospital, Central South University, Changsha, China
| | - Min Peng
- Division of Neonatology, Department of Pediatrics, The Second Xiangya Hospital, Central South University, Changsha, China.,Clinical Nursing Teaching and Research Section, The Second Xiangya Hospital, Central South University, Changsha, China
| | - Tian Cao
- Division of Neonatology, Department of Pediatrics, The Second Xiangya Hospital, Central South University, Changsha, China.,Clinical Nursing Teaching and Research Section, The Second Xiangya Hospital, Central South University, Changsha, China
| | - Yonghui Yang
- Division of Neonatology, Department of Pediatrics, The Second Xiangya Hospital, Central South University, Changsha, China
| | - Qin Wang
- Division of Neonatology, Department of Pediatrics, The Second Xiangya Hospital, Central South University, Changsha, China.,Clinical Nursing Teaching and Research Section, The Second Xiangya Hospital, Central South University, Changsha, China
| | - Kaiju Luo
- Division of Neonatology, Department of Pediatrics, The Second Xiangya Hospital, Central South University, Changsha, China
| | - Pingyang Chen
- Division of Neonatology, Department of Pediatrics, The Second Xiangya Hospital, Central South University, Changsha, China
| |
Collapse
|
29
|
Point-of-care ultrasound use in umbilical line placement: a review. J Perinatol 2020; 40:560-566. [PMID: 31758061 DOI: 10.1038/s41372-019-0558-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 10/16/2019] [Accepted: 11/08/2019] [Indexed: 11/08/2022]
Abstract
Point-of-care ultrasound (POCUS) has become a novel tool for assessing umbilical catheter tip location in the neonate. This review analyzes the current evidence on the efficacy and utility of POCUS for identifying umbilical catheter positioning. Medline, EMBASE, and Cochrane searches were performed until October 2018. Eight studies were identified comparing POCUS to x-ray in assessing umbilical catheter tip location in the last 10 years. POCUS was shown to be feasible and appears to be a superior imagining modality to x-rays in assessing umbilical line tip location. POCUS is more accurate in determining umbilical catheter positioning, allows for more rapid line umbilical catheter placement, and reduces the time to treatment as well as radiation exposure to the neonate when compared with x-ray. The available studies support further education in training neonatal providers to become proficient in POCUS for assessing umbilical lines.
Collapse
|
30
|
Abstract
PURPOSE OF REVIEW Point-of-care ultrasound (POCUS) is an emerging clinical tool in the neonatal intensive care unit (NICU). Recent literature describing the use of POCUS for various applications in the NICU has garnered increased interest among neonatologists. RECENT FINDINGS Diagnostic applications for POCUS in the NICU include the evaluation and serial monitoring of common pulmonary diseases, hemodynamic instability, patent ductus arteriosus (PDA), persistent pulmonary hypertension of the newborn (PPHN), necrotizing enterocolitis (NEC), and intraventricular hemorrhage (IVH), among others. Procedural applications include vascular access, endotracheal intubation, lumbar puncture, and fluid drainage. SUMMARY Experience with POCUS in the NICU is growing. Current evidence supports the use of POCUS for a number of diagnostic and procedural applications. As use of this tool increases, there is an urgent need to develop formal training requirements specific to neonatology, as well as evidence-based guidelines to standardize use across centers.
Collapse
|
31
|
Ultrasound-guided umbilical venous catheterisation: A cost-effectiveness analysis. ANALES DE PEDIATRÍA (ENGLISH EDITION) 2020. [DOI: 10.1016/j.anpede.2019.04.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
32
|
Umbilical venous catheter insertion depth estimation using birth weight versus surface measurement formula: a randomized controlled trial. J Perinatol 2020; 40:567-572. [PMID: 31383945 DOI: 10.1038/s41372-019-0456-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2019] [Revised: 05/31/2019] [Accepted: 06/17/2019] [Indexed: 11/08/2022]
Abstract
OBJECTIVE To determine if umbilical venous catheter (UVC) insertion depth estimated by surface measurement (SM) results in optimal catheter tip position on ultrasound as compared with formula using birth weight (BW). METHODS In this randomized controlled trial, eligible infants were randomized to UVC insertion depth estimated by SM or BW method. We compared proportion of optimum UVC position on ultrasound read by neonatologist masked with group assignment. RESULTS UVC was inserted to estimated depth in 164 of 200 enroled infants. There was no difference in the proportion of correctly positioned UVCs between the groups (SM 33/82 (40.2%) vs BW 27/82 (32.9%), p = 0.33). Among BW < 1000 g, SM method had higher correctly positioned UVC (43.7% vs 22.5%, p = 0.07). CONCLUSION There was no difference in the rate of optimally positioned UVC tip between the two methods for estimating UVC insertion depth. However, SM method results in more optimal positioning of UVC tip among BW < 1000 g infants.
Collapse
|
33
|
Seigel A, Evans N, Lutz T. Use of clinician-performed ultrasound in the assessment of safe umbilical venous catheter tip placement. J Paediatr Child Health 2020; 56:439-443. [PMID: 31654594 DOI: 10.1111/jpc.14658] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2019] [Revised: 08/27/2019] [Accepted: 09/09/2019] [Indexed: 11/29/2022]
Abstract
AIM Safe tip placement of umbilical venous catheters (UVCs) in sick neonates is critical in minimising risk. We aimed to demonstrate the utility of clinician-performed ultrasound (CPU) in identifying UVCs that are placed within small intrahepatic portal vessels or within the heart despite the appearance of being well placed on X-ray. METHODS This was a retrospective observational study of preterm and term neonates who had a UVC placed and the position assessed by X-ray and/or CPU according to the Royal Prince Alfred Hospital level 3 neonatal intensive care unit (NICU) guideline. Cases were identified by exporting the records of all admissions between 1 April 2015 and 30 June 2016 from the NICU's data collection database. Paper-based medical records, NICU's data collection database records and the ultrasound reporting system were reviewed to determine X-ray and CPU findings. RESULTS A total of 157 neonates had 169 UVCs placed. CPU was performed in 77% (111). In 15 cases (14%), UVC placement on X-ray appeared appropriate based on estimated vertebral level; however, CPU demonstrated the line to be in an unsafe position (small intrahepatic portal vessel (3); right atrium (9); left atrium (3)). CONCLUSIONS Assessment of safe UVC placement by estimations according to vertebral level on X-ray alone is inadequate. CPU offers confident localisation of the UVC tip and enables corrective manipulation of intracardiac or intrahepatic UVCs in real time. We recommend CPU as an adjunct to X-ray to ensure safe UVC placement.
Collapse
Affiliation(s)
- Amber Seigel
- Department of Newborn Care, Royal Prince Alfred Hospital and University of Sydney, Sydney, New South Wales, Australia
| | - Nick Evans
- Department of Newborn Care, Royal Prince Alfred Hospital and University of Sydney, Sydney, New South Wales, Australia.,Department of Obstetrics, Gynaecology and Neonatology, University of Sydney, Sydney, New South Wales, Australia
| | - Tracey Lutz
- Department of Newborn Care, Royal Prince Alfred Hospital and University of Sydney, Sydney, New South Wales, Australia.,Department of Obstetrics, Gynaecology and Neonatology, University of Sydney, Sydney, New South Wales, Australia
| |
Collapse
|
34
|
Kartikeswar GAP, Parikh TB, Pandya D, Pandit A. Ionizing Radiation Exposure in NICU. Indian J Pediatr 2020; 87:158-160. [PMID: 31833039 PMCID: PMC7222152 DOI: 10.1007/s12098-019-03126-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Accepted: 11/08/2019] [Indexed: 12/29/2022]
Abstract
The authors prospectively studied ionizing radiation exposure in consecutive 107 very low birth weight (VLBW) neonates, admitted to their Level III neonatal intensive care unit (NICU). Number of X-rays, their indications and calculated dose of radiation were documented. Their mean birth weight (+SD) and gestational age (+SD) were 1077 (±219.8) g and 29.7 (+2.57) wk respectively. Extremely low birth weight (ELBW) neonates underwent significantly higher radiographs when compared with VLBW neonates; 7.5(5-13.25) vs. 2(1-6); p < 0.0001. ELBW neonates received 3 times higher dose of radiation, when compared with VLBW neonates; 139.4 μsv (81.6-256.15) vs. 46.6 μsv (14.4-115.7); p < 0.0001. Seven percent of ELBW neonates received >1msv radiation. Lifetime risk associated with high radiation exposure during neonatal period is unknown. Every effort should be taken to reduce number of radiographs. Imaging modalities without radiation exposure such as, point of care ultrasound should be used wherever possible.
Collapse
Affiliation(s)
- G A P Kartikeswar
- Department of Pediatrics, Division of Neonatology, KEM Hospital, Pune, 411011, India
| | - Tushar B Parikh
- Department of Pediatrics, Division of Neonatology, KEM Hospital, Pune, 411011, India.
| | - Dhyey Pandya
- Department of Pediatrics, Division of Neonatology, KEM Hospital, Pune, 411011, India
| | - Anand Pandit
- Department of Pediatrics, Division of Neonatology, KEM Hospital, Pune, 411011, India
| |
Collapse
|
35
|
Hepatic extravasation complicated by umbilical venous catheterization in neonates: A 5-year, single-center experience. Pediatr Neonatol 2020; 61:16-24. [PMID: 31186169 DOI: 10.1016/j.pedneo.2019.05.004] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/03/2018] [Revised: 03/02/2019] [Accepted: 05/14/2019] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Care of newborns in the neonatal intensive care unit generally involves umbilical venous catheterization (UVC) for central vein access to enable medical needs. The study aimed to evaluate the sonographic appearance, risk factors, and outcomes of UVC-related hepatic extravasation (HE) in neonates. METHODS A 5-year retrospective study where 33 neonates were enrolled with a diagnosis age ranging from 2 to 25 days. 78.8% of the subjects had UVC malpositioning shown on initial radiography. All neonates sonographically diagnosed with HE, and follow-up ultrasound (US) was performed. RESULTS The main findings of HE on US were hyperechoic or heterogeneous lesions of a lobulated (51.7%) or wedge shape (48.3%), located mainly in the left lobe (72.7%). The mean time to resolution of HE was 2.25 months. Seven (21.2%) patients showed hepatic vascular thrombosis at follow-up. Two (6%) patients had abnormal liver function, which subsequently normalized. CONCLUSION Malposition of the UV catheter was the predisposing factor for UVC-related HE in neonates. US facilitates detection of UVC malpositioning and diagnosis of HE, as well as delayed complications. A shorter duration of UVC placement is associated with favorable outcomes of UVC-related HE in neonates.
Collapse
|
36
|
Akar S, Varan C. Evaluation of the distance between the xiphoid process and the umbilicus: Is it appropriate for the measurement of the umbilical venous catheter length? J Clin Neonatol 2020. [DOI: 10.4103/jcn.jcn_85_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
37
|
Anand V, Pournami F, Panackal AV, Nandakumar A, Prabhakar J, Jain N. Parenteral Nutrition Ascites: Calamity from an Umbilical Vein Cannula. JOURNAL OF CHILD SCIENCE 2020. [DOI: 10.1055/s-0040-1720957] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
AbstractUmbilical vein catheterization is considered a critical requirement in preterm neonates for the administration of fluids and parenteral nutrition. However, inadvertent migration and malposition are known to cause complications that are often life-threatening. We describe a neonate with parenteral nutrition-associated lipid ascites owing to extravasation from an umbilical vein cannula. Fatality was averted due to prompt recognition and paracentesis that was therapeutic and confirmed the diagnosis as well.
Collapse
Affiliation(s)
- Vishnu Anand
- Department of Neonatology, Kerala Institute of Medical Sciences, Trivandrum, Kerala, India
| | - Femitha Pournami
- Department of Neonatology, Kerala Institute of Medical Sciences, Trivandrum, Kerala, India
| | - Anila V. Panackal
- Department of Neonatology, Kerala Institute of Medical Sciences, Trivandrum, Kerala, India
| | - Anand Nandakumar
- Department of Neonatology, Kerala Institute of Medical Sciences, Trivandrum, Kerala, India
| | - Jyothi Prabhakar
- Department of Neonatology, Kerala Institute of Medical Sciences, Trivandrum, Kerala, India
| | - Naveen Jain
- Department of Neonatology, Kerala Institute of Medical Sciences, Trivandrum, Kerala, India
| |
Collapse
|
38
|
Introduction of point of care ultrasound into the neonatal intensive care unit. J Ultrasound 2020; 23:631-632. [PMID: 31894474 DOI: 10.1007/s40477-019-00419-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Accepted: 12/12/2019] [Indexed: 10/25/2022] Open
|
39
|
Sims ME. Legal Briefs: Venous Catheter Tips Need to Stay Out of the Heart. Neoreviews 2019; 20:e543-e547. [PMID: 31477605 DOI: 10.1542/neo.20-9-e543] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Affiliation(s)
- Maureen E Sims
- Department of Pediatrics, University of California, Los Angeles, Los Angeles, CA
| |
Collapse
|
40
|
[Ultrasound-guided umbilical venous catheterisation: A cost-effectiveness analysis]. An Pediatr (Barc) 2019; 92:215-221. [PMID: 31129027 DOI: 10.1016/j.anpedi.2019.04.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2018] [Revised: 03/28/2019] [Accepted: 04/08/2019] [Indexed: 11/21/2022] Open
Abstract
INTRODUCTION Although the use of ultrasound for the insertion of central catheters has proven to be cost-effective in adults, it is not known if this is the case in the neonatal population. This study compared the cost-effectiveness of ultrasound-guided umbilical venous catheterisation with conventional catheterisation in a neonatal intensive care unit of a Public University Hospital. PATIENTS AND METHODS A retrospective observational study was conducted on newborns that required an umbilical venous catheter before completing their first 24hours of extra-uterine life. Two retrospective cohorts were formed, including one with ultrasound-guided catheterisation and the other with conventional catheterisation. The effectiveness was measured using 2 variables: placement of ideal position and insertion without complications. The cost of human and material resources (consumable and non-consumable), the cost-effectiveness ratio, and the incremental cost-effectiveness ratio were estimated, as well as carrying out a sensitivity analysis. RESULTS Catheter obstruction was more frequent in guided catheterisation than in conventional catheterisation (7.7% vs. 0%, p=.04) and catheter dysfunction was higher in the latter (79% vs. 3.8%, p<.0001). The cost-effectiveness ratio of the guided catheterisation was €153.9, and €484.6 for the conventional one. The incremental cost-effectiveness ratio was €45.5. The sensitivity analysis showed a €2.6 increase in the cost-effectiveness ratio of the guided catheterisation and €47 in the conventional one. CONCLUSIONS The use of ultrasound to guide umbilical catheterisation is more efficient than conventional catheterisation since, despite using more economic resources, it offers greater effectiveness.
Collapse
|
41
|
Young A, Harrison K, Sellwood MW. How to use… Imaging for umbilical venous catheter placement. Arch Dis Child Educ Pract Ed 2019; 104:88-96. [PMID: 30104325 DOI: 10.1136/archdischild-2017-312662] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 07/02/2018] [Indexed: 02/07/2023]
|
42
|
Lean WL, Dawson JA, Davis PG, Theda C, Thio M. Accuracy of five formulae to determine the insertion length of umbilical venous catheters. Arch Dis Child Fetal Neonatal Ed 2019; 104:F165-F169. [PMID: 29550770 DOI: 10.1136/archdischild-2017-314280] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2017] [Revised: 02/21/2018] [Accepted: 02/26/2018] [Indexed: 12/13/2022]
Abstract
INTRODUCTION Umbilical venous catheter (UVC) placement is a common neonatal procedure. It is important to position the UVC tip accurately at the first attempt to prevent complications and minimise handling. Catheters positioned too low need to be removed, but catheters positioned too high may be withdrawn in a sterile fashion to a safe position. We aimed to determine the precision and accuracy of five published formulae developed to guide UVC placement. METHODS This was a prospective observational study. Following UVC insertion, anteroposterior and lateral X-rays were performed to identify catheter tip position. Parameters required to apply the five formulae were recorded. Insertion lengths were then calculated and compared with the gold standard (UVC tip at the level of the diaphragm on the lateral X-ray). They were also used to classify predicted UVC tip position as either correct (UVC tip at or up to 1 cm above the diaphragm), too high or too low. RESULTS Of 118 eligible infants, 70 had the UVC tip in a position where measurements could be used. Their median (IQR) gestational age and weight were 28.5 (26-36) weeks and 1035 (745-2788) g, respectively. The predicted success rate for each formula ranged from 44.9% to 55.7%. A formula based on birth weight had the highest rate of either correct or high position (95.8%). CONCLUSIONS Inserting a UVC into a safe position on first attempt is difficult and low tip placement is common. Around half of UVCs need to be manipulated to achieve the desired position.
Collapse
Affiliation(s)
- Wei Ling Lean
- Newborn Research Centre, The Royal Women's Hospital, Parkville, Victoria, Australia
| | - Jennifer A Dawson
- Newborn Research Centre, The Royal Women's Hospital, Parkville, Victoria, Australia.,Murdoch Children's Research Institute, Parkville, Victoria, Australia.,Department of Obstetrics and Gynaecology, The University of Melbourne, Melbourne, Victoria, Australia
| | - Peter G Davis
- Newborn Research Centre, The Royal Women's Hospital, Parkville, Victoria, Australia.,Murdoch Children's Research Institute, Parkville, Victoria, Australia.,Department of Obstetrics and Gynaecology, The University of Melbourne, Melbourne, Victoria, Australia
| | - Christiane Theda
- Newborn Research Centre, The Royal Women's Hospital, Parkville, Victoria, Australia.,Murdoch Children's Research Institute, Parkville, Victoria, Australia.,Department of Obstetrics and Gynaecology, The University of Melbourne, Melbourne, Victoria, Australia.,PIPER - Neonatal Retrieval Services Victoria, The Royal Children's Hospital, Melbourne, Victoria, Australia
| | - Marta Thio
- Newborn Research Centre, The Royal Women's Hospital, Parkville, Victoria, Australia.,Murdoch Children's Research Institute, Parkville, Victoria, Australia.,Department of Obstetrics and Gynaecology, The University of Melbourne, Melbourne, Victoria, Australia.,PIPER - Neonatal Retrieval Services Victoria, The Royal Children's Hospital, Melbourne, Victoria, Australia
| |
Collapse
|
43
|
Zaghloul N, Watkins L, Choi-Rosen J, Perveen S, Kurepa D. The superiority of point of care ultrasound in localizing central venous line tip position over time. Eur J Pediatr 2019; 178:173-179. [PMID: 30374753 DOI: 10.1007/s00431-018-3269-9] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2018] [Revised: 09/27/2018] [Accepted: 10/10/2018] [Indexed: 11/30/2022]
Abstract
The primary objective was to study agreement between X-rays and point of care ultrasound (POC-US) in determining central venous line (CVL) tip position. The secondary objective was to examine malposition rates over time using POC-US. Fifty-six neonates were enrolled who had a CVL placed. Initial X-rays and POC-US were obtained. POC-US was performed daily thereafter for the total of 6 days. US video clips were acquired in four standard echocardiographic views: subcostal, four-chamber, and short- and long-axis parasternal views. Gwet's agreement coefficient (AC1) for agreement measured inter-rater reliability of X-rays and POC-US (correct position/malposition). A generalized linear mixed model for binary clustered data estimated malposition rate over time. All analyses were conducted using SAS version 9.4 and Agree Stat. The study included 108 "pairs" of X-rays and POC-US images. Agreement coefficient (AC1), with respect to correct position/malposition of CVL tip, was high AC1 = 0.872 (UVC-AC1 = 0.814, PICC-AC1 = 0.94). Among birth weight (BW) < 1000 g, 1000-1499 g, and BW > 1500 g, AC1 values were 0.922, 0.774, and 0.873, respectively. CVL tip malposition rate decreased over time.Conclusions: Agreement between POC-US and X-rays for CVL tip position was high, with the highest in BW < 1000 g. The data suggest that POC-US can be used for initial confirmation and follow up of CVL tip position. What is Known • X-ray is currently the gold standard for localizing central venous line (CVL) tip position. • Malposition of CVL tip can lead to life-threatening complications. What is New • POC-US is superior to X-ray as it can follow CVL tip position over time, detecting malpositioned lines, adjusting them in a timely manner thus preventing complications. • Standardizing CVL placement, X-ray acquisition, POC-US acquisition with four views with video clips and ultrasound operator training increases accuracy and thus agreement between X-ray and POC-US. • UVC tip is more likely to be malpositoned than PICC tip. Malposition of UVC tip using POC-US decreased over time due to shrinking of the umbilical cord in the first 48 of life.
Collapse
Affiliation(s)
- Nahla Zaghloul
- Department of Pediatrics, Division of Neonatology, Cohen Children's Medical Center, New Hyde Park, NY, USA. .,Feinstein Institute for Medical Research, Manhasset, NY, USA. .,Hofstra University School of Medicine, Hempstead, NY, USA.
| | - Laura Watkins
- Department of Pediatrics, Pediatric Critical Care Division, Cohen Children's Medical Center, New Hyde Park, NY, USA
| | - Jennie Choi-Rosen
- Department of Pediatrics, Pediatric Radiology Department, Cohen Children's Medical Center, New Hyde Park, NY, USA
| | - Shahana Perveen
- Department of Pediatrics, Division of Neonatology, Cohen Children's Medical Center, New Hyde Park, NY, USA
| | - Dalibor Kurepa
- Department of Pediatrics, Division of Neonatology, Cohen Children's Medical Center, New Hyde Park, NY, USA
| |
Collapse
|
44
|
Dubbink-Verheij GH, Visser R, Tan RNGB, Roest AAW, Lopriore E, Te Pas AB. Inadvertent Migration of Umbilical Venous Catheters Often Leads to Malposition. Neonatology 2019; 115:205-210. [PMID: 30645997 PMCID: PMC6518856 DOI: 10.1159/000494369] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2018] [Accepted: 10/09/2018] [Indexed: 12/20/2022]
Abstract
BACKGROUND Migration of umbilical venous catheters (UVCs) has been described anecdotally. OBJECTIVES The aim of this paper was to investigate migration of UVCs using ultrasonography (US). METHODS In a prospective observational study, the position of UVCs was determined using serial US within 24 h, at midweek, and at the end of the week after umbilical catheterization. Migration was recorded in distance and direction. Malposition was defined as a position of the UVC in the heart (right atrium or more distal along the UVC-route), umbilicoportal confluence, or in the umbilical vein. UVC position determined by US was compared with chest X-rays (CXRs) when these were performed for standard care within the same period of 1 h. RESULTS Migration of UVCs was detected with US in 25/40 infants (63%) in 32 occasions, leading to malposition in 17/25 (68%) infants. UVCs migrated inwards in 18/32 (56%), leading to a position within the heart in 17/18 occasions. Most migrations occurred before Day 3 (21/32 [66%]). When a CXR was taken at the same time as US was performed (30 occasions), the assessment of the catheter-tip position differed in 23% of the occasions. When malposition was detected by US, this was detected on routinely performed CXRs in 11% of the occasions. CONCLUSIONS UVCs often migrate following insertion, often leading to malposition. Awareness for this is needed, and US is a feasible alternative for detecting malposition compared to CXRs and avoids additional radiation. Re-evaluation of the position of UVCs at least once, but within 24 h after placement, is recommended.
Collapse
Affiliation(s)
- Gerdina H Dubbink-Verheij
- Division of Neonatology, Department of Pediatrics, Leiden University Medical Center, Leiden, The Netherlands,
| | - Remco Visser
- Division of Neonatology, Department of Pediatrics, Leiden University Medical Center, Leiden, The Netherlands
| | - Ratna N G B Tan
- Division of Neonatology, Department of Pediatrics, Leiden University Medical Center, Leiden, The Netherlands
| | - Arno A W Roest
- Division of Cardiology, Department of Pediatrics, Leiden University Medical Center, Leiden, The Netherlands
| | - Enrico Lopriore
- Division of Neonatology, Department of Pediatrics, Leiden University Medical Center, Leiden, The Netherlands
| | - Arjan B Te Pas
- Division of Neonatology, Department of Pediatrics, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
45
|
A National Survey of Neonatologists: Barriers and Prerequisites to Introduce Point-of-Care Ultrasound in Neonatal ICUs. Ultrasound Q 2018; 33:265-271. [PMID: 28430713 DOI: 10.1097/ruq.0000000000000281] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Point-of-care (POC) ultrasound refers to the use of portable imaging. Although POC ultrasound is widely available to the neonatologists in Australia and Europe, neonatologists in the United States report limited availability. Our objective was to seek the US neonatologists' perception of barriers and prerequisites in adopting POC ultrasound in neonatal intensive care units. An online survey link was sent via e-mail to 3000 neonatologists included in the database maintained by the American Academy of Pediatrics. Survey results (n = 574) were reported as percentage of total responses. Personal experience requiring an urgent sonography in managing cardiac tamponade or pleural effusion was reported by 78% respondents. However, emergent ultrasound (≤10 min) was not available in 80% of the neonatal intensive care units. We compared the responses based on years of clinical experience (>20 vs <20 years), with 272 (48%) neonatologist reporting more than 20 years of experience. Similarly, results from neonatal fellowship programs were compared with nonteaching/teaching hospitals, with 288 (50%) replies from neonatology fellowship programs. Compared with senior neonatologists, respondents with less than 20 years of clinical experience consider POC ultrasound enhances safety and accuracy of clinical procedures (87% vs 82%) and favor adopting POC ultrasound in clinical practice (92% vs 84%). There were no differences in opinion from neonatology fellowship programs compared with the nonteaching/teaching hospitals. Lack of training guidelines, inadequate support from local radiology department, and legal concerns were reported as the top 3 primary barriers in adopting POC ultrasound. If these barriers could be resolved, 89% respondents were inclined to adopt POC ultrasound in clinical practice.
Collapse
|
46
|
Selvam S, Humphrey T, Woodley H, English S, Kraft JK. Sonographic features of umbilical catheter-related complications. Pediatr Radiol 2018; 48:1964-1970. [PMID: 30078110 DOI: 10.1007/s00247-018-4214-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2018] [Revised: 06/09/2018] [Accepted: 07/13/2018] [Indexed: 02/07/2023]
Abstract
Umbilical catheters are commonly used in the neonatal period for blood sampling or for administering medication or parenteral nutrition. The position of the catheter is usually confirmed with radiography. However, many complications associated with the use of umbilical catheters, such as liver collections from extravasation or vascular thrombosis, are not apparent on radiographs but can be easily diagnosed with ultrasound. This pictorial review illustrates the sonographic findings of complications that should be excluded in the sick neonate with an indwelling catheter.
Collapse
Affiliation(s)
- Swathi Selvam
- Clarendon Wing Radiology Department, Leeds Children's Hospital at Leeds General Infirmary, Belmont Grove, Leeds, West Yorkshire, LS2 9NS, UK
| | - Terry Humphrey
- Clarendon Wing Radiology Department, Leeds Children's Hospital at Leeds General Infirmary, Belmont Grove, Leeds, West Yorkshire, LS2 9NS, UK
| | - Helen Woodley
- Clarendon Wing Radiology Department, Leeds Children's Hospital at Leeds General Infirmary, Belmont Grove, Leeds, West Yorkshire, LS2 9NS, UK
| | - Sharon English
- Department of Neonatology, Leeds Children's Hospital at Leeds General Infirmary, Leeds, UK
| | - Jeannette K Kraft
- Clarendon Wing Radiology Department, Leeds Children's Hospital at Leeds General Infirmary, Belmont Grove, Leeds, West Yorkshire, LS2 9NS, UK.
| |
Collapse
|
47
|
Lee HM, Sung HJ, Lee HS. Umbilical Venous Catheter Complication Presenting as Chylous Ascites in a Newborn: Intraperitoneal Extravasation of Total Parenteral Nutrition Infusate. NEONATAL MEDICINE 2018. [DOI: 10.5385/nm.2018.25.4.196] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
|
48
|
Diagnostic Bedside Ultrasound Program Development in Pediatric Critical Care Medicine: Results of a National Survey. Pediatr Crit Care Med 2018; 19:e561-e568. [PMID: 30113518 DOI: 10.1097/pcc.0000000000001692] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVES To assess current diagnostic bedside ultrasound program core element (training, credentialing, image storage, documentation, and quality assurance) implementation across pediatric critical care medicine divisions in the United States. DESIGN Cross-sectional questionnaire-based needs assessment survey. SETTING Pediatric critical care medicine divisions with an Accreditation Council of Graduate Medical Education-accredited fellowship. RESPONDENTS Divisional leaders in education and/or bedside ultrasound training. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS Fifty-five of 67 pediatric critical care medicine divisions (82%) with an Accreditation Council of Graduate Medical Education-accredited fellowship provided responses. Overall, 63% of responding divisions (34/54) were clinically performing diagnostic bedside ultrasound studies with no difference between divisions with large versus small units. Diagnostic bedside ultrasound training is available for pediatric critical care medicine fellows within 67% of divisions (35/52) with no difference in availability between divisions with large versus small units. Other core elements were present in less than 25% of all divisions performing clinical studies, with a statistically significant increase in credentialing and documentation among divisions with large units (p = 0.048 and 0.01, respectively). All core elements were perceived to have not only high impact in program development but also high effort in implementation. Assuming that all structural elements could be effectively implemented within their division, 83% of respondents (43/52) agreed that diagnostic bedside ultrasound should be a core curricular component of fellowship education. CONCLUSIONS Diagnostic bedside ultrasound is increasingly prevalent in training and clinical use across the pediatric critical care medicine landscape despite frequently absent core programmatic infrastructural elements. These core elements are perceived as important to program development, regardless of division unit size. Shared standardized resources may assist in reducing the effort in core element implementation and allow us to measure important educational and clinical outcomes.
Collapse
|
49
|
Derinkuyu BE, Boyunaga OL, Damar C, Unal S, Ergenekon E, Alimli AG, Oztunali C, Turkyilmaz C. Hepatic Complications of Umbilical Venous Catheters in the Neonatal Period: The Ultrasound Spectrum. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2018; 37:1335-1344. [PMID: 29034490 DOI: 10.1002/jum.14443] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 08/14/2017] [Indexed: 06/07/2023]
Abstract
OBJECTIVES Umbilical venous catheterization is commonly used in the neonatal period; however, it has some complications. In this study, we evaluated neonates who underwent umbilical venous catheterization and developed hepatic complications. Furthermore, we aimed to define all of the possible lesions and to clarify the imaging findings of umbilical venous catheter-induced hepatic injury. METHODS Two hundred forty-four neonates who underwent umbilical venous catheterization between March 2013 and September 2015 in a single tertiary care referral center were included in this study. To determine whether they had any hepatic complications, all patients underwent abdominal grayscale and Doppler ultrasound examinations, and their clinical data were recorded. RESULTS The frequency of liver-related complications from umbilical venous catheterization was 33.6% (82 of 244). Air in the portal venous system was the most frequent complication (20.1% [49 of 244]). Left portal venous thrombosis was noted in 6.1% (15 of 244). Parenchymal lesions in the liver related to umbilical venous catheterization were seen in 7.4% of patients (18 of 244) as follows: single nodular echogenic lesions (4.1% [10 of 244]), branching small nodular echogenic lesions (2.1% [5 of 244]), and large irregular heterogeneous lesions with laceration and perihepatic fluid (1.2% [3 of 244]). There was no statistical significance for any type of complication according to the gestational age (P > .05). CONCLUSIONS Hepatic complications due to umbilical venous catheters are not uncommon in the neonatal period. Ultrasound is the best imaging modality for confirming the diagnosis and for follow-up.
Collapse
Affiliation(s)
- Betul Emine Derinkuyu
- Departments of Pediatric Radiology, Gazi University Faculty of Medicine, Ankara, Turkey
| | - Oznur Leman Boyunaga
- Departments of Pediatric Radiology, Gazi University Faculty of Medicine, Ankara, Turkey
| | - Cagri Damar
- Departments of Pediatric Radiology, Gazi University Faculty of Medicine, Ankara, Turkey
| | - Sezin Unal
- Departments of Neonatology, Gazi University Faculty of Medicine, Ankara, Turkey
| | - Ebru Ergenekon
- Departments of Neonatology, Gazi University Faculty of Medicine, Ankara, Turkey
| | - Ayse Gul Alimli
- Departments of Pediatric Radiology, Gazi University Faculty of Medicine, Ankara, Turkey
| | - Cigdem Oztunali
- Departments of Pediatric Radiology, Gazi University Faculty of Medicine, Ankara, Turkey
| | - Canan Turkyilmaz
- Departments of Neonatology, Gazi University Faculty of Medicine, Ankara, Turkey
| |
Collapse
|
50
|
Smith A, Breatnach CR, James AT, Franklin O, El-Khuffash A. Incidental Findings on Routine Targeted Neonatal Echocardiography Performed in Preterm Neonates Younger Than 29 Weeks' Gestation. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2018; 37:843-849. [PMID: 28945279 DOI: 10.1002/jum.14422] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2017] [Revised: 06/20/2017] [Accepted: 06/28/2017] [Indexed: 06/07/2023]
Abstract
OBJECTIVES The aim of this study was to quantify the rate of incidental findings identified on elective research echocardiography performed on neonates younger than 29 weeks' gestation. METHODS We conducted a retrospective study of echocardiographic examinations performed within the first 24 hours of age on neonates younger than 29 weeks' gestation over a 3-year period for research purposes. Incidental echocardiographic findings and pertinent clinical data were recorded. RESULTS Echocardiographic examinations performed on 145 neonates were retrospectively reviewed. Forty-three neonates (30%) had a total of 54 unexpected findings (37%). Most comprised malpositioned umbilical venous catheters, where the tip was located in the left atrium. The remainder of the conditions identified included unsuspected congenital heart disease, liver hematomas, and unexpected pulmonary hypertension. CONCLUSIONS There is a high rate of incidental findings identified on screening echocardiograms. Routine targeted neonatal echocardiographic screening of preterm neonates may be warranted to identify the considerable likelihood of asymptomatic findings.
Collapse
Affiliation(s)
- Aisling Smith
- Department of Neonatology, Rotunda Hospital, Dublin, Ireland
| | | | - Adam T James
- Department of Neonatology, Rotunda Hospital, Dublin, Ireland
| | - Orla Franklin
- Department of Cardiology, Our Lady's Children's Hospital, Crumlin, Dublin, Ireland
| | - Afif El-Khuffash
- Department of Neonatology, Rotunda Hospital, Dublin, Ireland
- Department of Pediatrics, School of Medicine, Royal College of Surgeons in Ireland, Dublin, Ireland
| |
Collapse
|