1
|
Pallotta S, Marrazzo L, Calusi S, Castriconi R, Fiorino C, Loi G, Fiandra C. Implementation of automatic plan optimization in Italy: Status and perspectives. Phys Med 2021; 92:86-94. [PMID: 34875426 DOI: 10.1016/j.ejmp.2021.11.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 11/20/2021] [Accepted: 11/24/2021] [Indexed: 01/04/2023] Open
Abstract
PURPOSE To investigate and report on the diffusion and clinical use of automated radiotherapy planning systems in Italy and to assess the perspectives of the community of Italian medical physicists involved in radiotherapy on the use of these tools. MATERIALS AND METHODS A survey of medical physicists (one per Institute) of 175 radiotherapy centers in Italy was conducted between February 21st and April 1st, 2021. The information collected included the institute's characteristics, plan activity, availability/use of automatic tools and related issues regarding satisfaction, criticisms, expectations, and perceived professional modifications. Responses were analysed, including the impact of a few variables such as the institute type and experience. RESULTS 125 of the centers (71%) answered the survey, with regional variability (range: 47%-100%); among these, 49% have a TPS with some automatic option. Clinical use of automatic planning is present in 33% of the centers, with 13% applying it in >50% of their plans. Among the 125 responding centres the most used systems are Pinnacle (16%), Raystation (9%) and Eclipse (4%). The majority of participants consider the use of automated techniques to be beneficial, while only 1% do not see any advantage; 83% of respondents see the possibility of enriching their professional role as a potential benefit, while 3% see potential threats. CONCLUSIONS Our survey shows that 49% of the responding centres have an automatic planning solution although clinically used in only 33% of the cases. Most physicists consider the use of automated techniques to be beneficial and show a prevalently positive attitude.
Collapse
Affiliation(s)
- Stefania Pallotta
- University of Florence, Department of Biomedical, Experimental and Clinical Sciences "Mario Serio", Florence, Italy; Medical Physics Unit, AOU Careggi, Florence, Italy.
| | | | - Silvia Calusi
- University of Florence, Department of Biomedical, Experimental and Clinical Sciences "Mario Serio", Florence, Italy
| | | | - Claudio Fiorino
- Medical Physics, San Raffaele Scientific Institute, Milano, Italy
| | - Gianfranco Loi
- Medical Physics, AOU Maggiore della Carità, Novara, Italy
| | | |
Collapse
|
2
|
Marrazzo L, Arilli C, Pellegrini R, Bonomo P, Calusi S, Talamonti C, Casati M, Compagnucci A, Livi L, Pallotta S. Automated planning through robust templates and multicriterial optimization for lung VMAT SBRT of lung lesions. J Appl Clin Med Phys 2020; 21:114-120. [PMID: 32275353 PMCID: PMC7324702 DOI: 10.1002/acm2.12872] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Revised: 03/05/2020] [Accepted: 03/10/2020] [Indexed: 12/24/2022] Open
Abstract
Purpose To develop and validate a robust template for VMAT SBRT of lung lesions, using the multicriterial optimization (MCO) of a commercial treatment planning system. Methods The template was established and refined on 10 lung SBRT patients planned for 55 Gy/5 fr. To improve gradient and conformity a ring structure around the planning target volume (PTV) was set in the list of objectives. Ideal fluence optimization was conducted giving priority to organs at risk (OARs) and using the MCO, which further pushes OARs doses. Segmentation was conducted giving priority to PTV coverage. Two different templates were produced with different degrees of modulation, by setting the Fluence Smoothing parameter to Medium (MFS) and High (HFS). Each template was applied on 20 further patients. Automatic and manual plans were compared in terms of dosimetric parameters, delivery time, and complexity. Statistical significance of differences was evaluated using paired two‐sided Wilcoxon signed‐rank test. Results No statistically significant differences in PTV coverage and maximum dose were observed, while an improvement was observed in gradient and conformity. A general improvement in dose to OARs was seen, which resulted to be significant for chest wall V30 Gy, total lung V20 Gy, and spinal cord D0.1 cc. MFS plans are characterized by a higher modulation and longer delivery time than manual plans. HFS plans have a modulation and a delivery time comparable to manual plans, but still present an advantage in terms of gradient. Conclusion The automation of the planning process for lung SBRT using robust templates and MCO was demonstrated to be feasible and more efficient.
Collapse
Affiliation(s)
- Livia Marrazzo
- Careggi University Hospital, Medical Physic Unit, Florence, Italy
| | - Chiara Arilli
- Careggi University Hospital, Medical Physic Unit, Florence, Italy
| | | | | | - Silvia Calusi
- Department of Experimental and Clinical Biomedical Sciences "Mario Serio", University of Florence, Florence, Italy
| | - Cinzia Talamonti
- Careggi University Hospital, Medical Physic Unit, Florence, Italy.,Department of Experimental and Clinical Biomedical Sciences "Mario Serio", University of Florence, Florence, Italy
| | - Marta Casati
- Careggi University Hospital, Medical Physic Unit, Florence, Italy
| | | | - Lorenzo Livi
- Careggi University Hospital, Radiotherapy Unit, Florence, Italy.,Department of Experimental and Clinical Biomedical Sciences "Mario Serio", University of Florence, Florence, Italy
| | - Stefania Pallotta
- Careggi University Hospital, Medical Physic Unit, Florence, Italy.,Department of Experimental and Clinical Biomedical Sciences "Mario Serio", University of Florence, Florence, Italy
| |
Collapse
|
3
|
Te Velde BL, Westhuyzen J, Awad N, Wood M, Shakespeare TP. Late toxicities of prostate cancer radiotherapy with and without hydrogel SpaceAOR insertion. J Med Imaging Radiat Oncol 2019; 63:836-841. [PMID: 31520465 DOI: 10.1111/1754-9485.12945] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Accepted: 07/29/2019] [Indexed: 12/30/2022]
Abstract
INTRODUCTION To investigate whether the implantation of a hydrogel spacer (SpaceOAR) reduces long-term rectal toxicity for prostate cancer patients treated with intensity-modulated radiotherapy (IMRT). METHODS Patients with localised prostate cancer treated with 81 Gy in 45 fx of IMRT over 9 weeks were retrospectively compared: 65 patients with SpaceOAR and 56 patients without SpaceOAR. Planning aims restricted rectal doses to V40 Gy < 35%, V65 Gy < 17%, V75 Gy < 10%. Toxicities were evaluated between 3 months and 3 years after the completion of radiotherapy and were based on the common terminology criteria for adverse events (CTCAE) assessment tool for diarrhoea, haemorrhoids, faecal incontinence and proctitis. RESULTS The cumulative incidence of low-grade diarrhoea (G1) was significantly higher in the non-SpaceOAR group (21.4% vs 6.2%; P = 0.016). The cumulative incidence of proctitis (grades G1 and G2) was also higher in the non-SpaceOAR group (26.7% vs 9.2%; P = 0.015); the cumulative incidence of G2 proctitis was higher in the latter group (P = 0.043). There were no differences between the treatment groups for cumulative incidences of faecal incontinence and/or haemorrhoids. Three years after IMRT, diarrhoea and proctitis were higher in the non-SpaceOAR group, without reaching statistical significance. This finding was unchanged after correcting for baseline symptoms. CONCLUSION SpaceOAR is of benefit in reducing the cumulative incidence of low-grade diarrhoea and proctitis for up to 3 years after intensity-modulated radiotherapy.
Collapse
Affiliation(s)
- Bridget L Te Velde
- Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour, New South Wales, Australia
| | - Justin Westhuyzen
- Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour, New South Wales, Australia
| | - Nader Awad
- Urology Centre, Port Macquarie, New South Wales, Australia
| | - Maree Wood
- Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour, New South Wales, Australia
| | - Thomas P Shakespeare
- Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour, New South Wales, Australia
| |
Collapse
|
4
|
Nystrom H, Jensen MF, Nystrom PW. Treatment planning for proton therapy: what is needed in the next 10 years? Br J Radiol 2019; 93:20190304. [PMID: 31356107 DOI: 10.1259/bjr.20190304] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Treatment planning is the process where the prescription of the radiation oncologist is translated into a deliverable treatment. With the complexity of contemporary radiotherapy, treatment planning cannot be performed without a computerized treatment planning system. Proton therapy (PT) enables highly conformal treatment plans with a minimum of dose to tissues outside the target volume, but to obtain the most optimal plan for the treatment, there are a multitude of parameters that need to be addressed. In this review areas of ongoing improvements and research in the field of PT treatment planning are identified and discussed. The main focus is on issues of immediate clinical and practical relevance to the PT community highlighting the needs for the near future but also in a longer perspective. We anticipate that the manual tasks performed by treatment planners in the future will involve a high degree of computational thinking, as many issues can be solved much better by e.g. scripting. More accurate and faster dose calculation algorithms are needed, automation for contouring and planning is required and practical tools to handle the variable biological efficiency in PT is urgently demanded just to mention a few of the expected improvements over the coming 10 years.
Collapse
Affiliation(s)
- Hakan Nystrom
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.,Skandionkliniken, Uppsala, Sweden
| | | | - Petra Witt Nystrom
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.,Skandionkliniken, Uppsala, Sweden
| |
Collapse
|
5
|
Hoffmann M, Pacey J, Goodworth J, Laszcyzk A, Ford R, Chick B, Greenham S, Westhuyzen J. Analysis of a volumetric-modulated arc therapy (VMAT) single phase prostate template as a class solution. Rep Pract Oncol Radiother 2018; 24:92-96. [PMID: 30505239 DOI: 10.1016/j.rpor.2018.10.009] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Revised: 09/26/2018] [Accepted: 10/28/2018] [Indexed: 12/31/2022] Open
Abstract
Aim To assess a class solution template for volumetric-modulated arc therapy (VMAT) for prostate cancer using plan analysis software. Background VMAT is a development of intensity-modulated radiotherapy (IMRT) with potential advantages for the delivery of radiotherapy (RT) in prostate cancer. Class solutions are increasingly used for facilitating RT planning. Plan analysis software provides an objective tool for evaluating class solutions. Materials and methods The class solution for VMAT was based on the current static field IMRT template. The plans of 77 prostate cancer patients were evaluated using a set of in-house plan quality metrics (scores) (PlanIQ™, Sun Nuclear Corporation). The metrics compared the class solution for VMAT planning with the IMRT template and the delivered clinical plan (CP). Eight metrics were associated with target coverage and ten with organs-at-risk (OAR). Individual metrics were summed and the combined scores were subjected to non-parametric analysis. The low-dose wash for both static IMRT and VMAT plans were evaluated using 40 Gy and 25 Gy isodose volumes. Results VMAT plans were of equal or better quality than the IMRT template and CP for target coverage (combined score) and OAR combined score. The 40 Gy isodose volume was marginally higher with VMAT than IMRT (4.9%) but lower than CP (-6.6%)(P = 0.0074). The 25 Gy volume was significantly lower with VMAT than both IMRT (-32.7%) and CP (-34.4%)(P < 0.00001). Conclusions Automated VMAT planning for prostate cancer is feasible and the plans are equal to or better than the current IMRT class solution and the delivered clinical plan.
Collapse
Affiliation(s)
- Matthew Hoffmann
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Port Macquarie, New South Wales, Australia
| | - Jacqueline Pacey
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour, New South Wales, Australia
| | - Josie Goodworth
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour, New South Wales, Australia
| | - Andrea Laszcyzk
- Department of Radiation Oncology, Northern New South Wales Cancer Institute, Lismore, New South Wales, Australia
| | - Richard Ford
- Department of Radiation Oncology, Northern New South Wales Cancer Institute, Lismore, New South Wales, Australia
| | - Brendon Chick
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Port Macquarie, New South Wales, Australia
| | - Stuart Greenham
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour, New South Wales, Australia
| | - Justin Westhuyzen
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour, New South Wales, Australia
| |
Collapse
|
6
|
Clarke S, Goodworth J, Westhuyzen J, Chick B, Hoffmann M, Pacey J, Greenham S. Software-based evaluation of a class solution for prostate IMRT planning. Rep Pract Oncol Radiother 2017; 22:441-449. [PMID: 28883765 DOI: 10.1016/j.rpor.2017.08.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2017] [Revised: 07/21/2017] [Accepted: 08/02/2017] [Indexed: 11/30/2022] Open
Abstract
AIM To use plan analysis software to evaluate a class solution for prostate intensity modulated radiotherapy (IMRT) planning. BACKGROUND Class solutions for radiotherapy planning are increasingly being considered for streamlining planning. Plan analysis software provides an objective approach to evaluating radiotherapy plans. MATERIALS AND METHODS Three iterations of a class solution for prostate IMRT planning (T1, T2 and Tfinal) were compared to the clinical plan of 74 prostate patients using radiotherapy plan analysis software (Plan IQ™, Sun Nuclear Corporation). A set of institution-specific plan quality metrics (scores) were established, based on best practice guidelines. RESULTS For CTV coverage, Tfinal was not significantly different to the clinical plan. With the exception of 95% PTV coverage, Tfinal metrics were significantly better than the clinical plan for PTV coverage. In the scoring analysis, mean dose, 95% and 107% isodose coverage scores were similar for all the templates and clinical plan. 100% coverage of the CTV clinical plan was similar to Tfinal but scored higher than T1 and T2. There were no significant differences between Tfinal and the clinical plan for the metrics and scores associated with organs at risk. The total plan score was similar for Tfinal and the clinical plan, although the scores for volume receiving total dose outside the PTV were higher for Tfinal than for the clinical plan (P < 0.0001). CONCLUSIONS The radiotherapy plan analysis software was useful for evaluating a class solution for prostate IMRT planning and provided evidence that the class solution produced clinically acceptable plans for these patients.
Collapse
Affiliation(s)
- Sarah Clarke
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Port Macquarie, New South Wales 2444, Australia
| | - Josie Goodworth
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour Health Campus, Coffs Harbour, New South Wales 2450, Australia
| | - Justin Westhuyzen
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour Health Campus, Coffs Harbour, New South Wales 2450, Australia
| | - Brendan Chick
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Port Macquarie, New South Wales 2444, Australia
| | - Matthew Hoffmann
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Port Macquarie, New South Wales 2444, Australia
| | - Jacqueline Pacey
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour Health Campus, Coffs Harbour, New South Wales 2450, Australia
| | - Stuart Greenham
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour Health Campus, Coffs Harbour, New South Wales 2450, Australia
| |
Collapse
|
7
|
Te Velde BL, Westhuyzen J, Awad N, Wood M, Shakespeare TP. Can a peri-rectal hydrogel spaceOAR programme for prostate cancer intensity-modulated radiotherapy be successfully implemented in a regional setting? J Med Imaging Radiat Oncol 2017; 61:528-533. [PMID: 28151584 DOI: 10.1111/1754-9485.12580] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Accepted: 12/11/2016] [Indexed: 11/27/2022]
Abstract
INTRODUCTION The aim of this study was to investigate whether the implementation of a hydrogel spacer (SpaceOAR) programme for patients treated with 81 Gy prostate intensity-modulated radiotherapy (IMRT) in a regional setting can reduce rectal doses and toxicity. METHODS In this retrospective study, 125 patients with localised prostate cancer treated between April 2014 (programme commencement) and June 2015 were compared: 65 with SpaceOAR (inserted by five different urologists) and 60 patients treated over the same time period without SpaceOAR. Patients were treated with 81 Gy in 45Fx of IMRT over 9 weeks. Planning aims included restricting rectal doses to V40 Gy < 35%, V65 Gy < 17%, V75 Gy < 10%. Acute toxicity was assessed weekly during radiotherapy and at 12 weeks. RESULTS Rectal volume parameters were all significantly lower in the SpaceOAR group, with an associated reduction in acute diarrhoea (13.8% vs 31.7%). There were no significant differences in the very low rates of acute and late faecal incontinence or proctitis, however, there was a trend towards increased haemorrhoid rate in the SpaceOAR group (11.7% vs 3.1%, P = 0.09). CONCLUSION A SpaceOAR programme in a regional setting with urologists performing low volumes of insertions (<1 per month on average) is of clinical benefit, and was associated with significantly lower radiation doses to the rectum and lower rates of acute diarrhoea.
Collapse
Affiliation(s)
- Bridget L Te Velde
- Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour, New South Wales, Australia
| | - Justin Westhuyzen
- Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour, New South Wales, Australia
| | - Nader Awad
- Radiation Oncology, Mid-North Coast Cancer Institute, Port Macquarie, New South Wales, Australia
| | - Maree Wood
- Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour, New South Wales, Australia
| | - Thomas P Shakespeare
- Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour, New South Wales, Australia
| |
Collapse
|