1
|
Adedara IA, Atanda OE, Sant'Anna Monteiro C, Rosemberg DB, Aschner M, Farombi EO, Rocha JBT, Furian AF, Emanuelli T. Cellular and molecular mechanisms of aflatoxin B 1-mediated neurotoxicity: The therapeutic role of natural bioactive compounds. ENVIRONMENTAL RESEARCH 2023; 237:116869. [PMID: 37567382 DOI: 10.1016/j.envres.2023.116869] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 08/05/2023] [Accepted: 08/08/2023] [Indexed: 08/13/2023]
Abstract
Aflatoxin B1 (AFB1), a dietary toxin from the mold Aspergillus species, is well acknowledged to elicit extra-hepatic toxicity in both animals and humans. The neurotoxicity of AFB1 has become a global public health concern. Contemporary research on how AFB1 enters the brain to elicit neuronal dysregulation leading to noxious neurological outcomes has increased greatly in recent years. The current review discusses several neurotoxic outcomes and susceptible targets of AFB1 toxicity at cellular, molecular and genetic levels. Specifically, neurotoxicity studies involving the use of brain homogenates, neuroblastoma cell line IMR-32, human brain microvascular endothelial cells, microglial cells, and astrocytes, as well as mammalian and non-mammalian models to unravel the mechanisms associated with AFB1 exposure are highlighted. Further, some naturally occurring bioactive compounds with compelling therapeutic effects on AFB1-induced neurotoxicity are reviewed. In conclusion, available data from literature highlight AFB1 as a neurotoxin and its possible pathological contribution to neurological disorders. Further mechanistic studies aimed at discovering and developing effective therapeutics for AFB1 neurotoxicity is warranted.
Collapse
Affiliation(s)
- Isaac A Adedara
- Department of Food Science and Technology, Center of Rural Sciences, Federal University of Santa Maria, Camobi, 97105-900 Santa Maria, RS, Brazil; Drug Metabolism and Toxicology Research Laboratories, Department of Biochemistry, College of Medicine, University of Ibadan, Ibadan, Nigeria.
| | - Oluwadarasimi E Atanda
- Human Toxicology Program, Department of Occupational and Environmental Health, University of Iowa, Iowa City, IA, 52242, USA
| | - Camila Sant'Anna Monteiro
- Department of Food Science and Technology, Center of Rural Sciences, Federal University of Santa Maria, Camobi, 97105-900 Santa Maria, RS, Brazil
| | - Denis B Rosemberg
- Laboratory of Experimental Neuropsychobiology, Department of Biochemistry and Molecular Biology, Federal University of Santa Maria, Camobi, 97105-900 Santa Maria, RS, Brazil
| | - Michael Aschner
- Department of Molecular Pharmacology; Albert Einstein College of Medicine Forchheimer 209; 1300 Morris Park Avenue, Bronx, NY 10461, USA
| | - Ebenezer O Farombi
- Drug Metabolism and Toxicology Research Laboratories, Department of Biochemistry, College of Medicine, University of Ibadan, Ibadan, Nigeria
| | - Joao B T Rocha
- Department of Biochemical and Molecular Biology, Federal University of Santa Maria, 97105-900, Santa Maria, RS, Brazil
| | - Ana Flávia Furian
- Department of Food Science and Technology, Center of Rural Sciences, Federal University of Santa Maria, Camobi, 97105-900 Santa Maria, RS, Brazil
| | - Tatiana Emanuelli
- Department of Food Science and Technology, Center of Rural Sciences, Federal University of Santa Maria, Camobi, 97105-900 Santa Maria, RS, Brazil
| |
Collapse
|
2
|
Mikani M, Rahmanian R. Sensitive Biosensor Based on Urease/In2O5Sn Nano-Coated Fluorinated SnO2 for Urea Detection in Blood Serum. JOURNAL OF ANALYTICAL CHEMISTRY 2021. [DOI: 10.1134/s1061934821080116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
3
|
Wu HL, Wang T, Yu RQ. Recent advances in chemical multi-way calibration with second-order or higher-order advantages: Multilinear models, algorithms, related issues and applications. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115954] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
4
|
Analytical chemistry assisted by multi-way calibration: A contribution to green chemistry. Talanta 2019; 204:700-712. [DOI: 10.1016/j.talanta.2019.06.022] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2019] [Revised: 06/05/2019] [Accepted: 06/06/2019] [Indexed: 12/30/2022]
|
5
|
Alcaraz MR, Monago-Maraña O, Goicoechea HC, Muñoz de la Peña A. Four- and five-way excitation-emission luminescence-based data acquisition and modeling for analytical applications. A review. Anal Chim Acta 2019; 1083:41-57. [PMID: 31493809 DOI: 10.1016/j.aca.2019.06.059] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Revised: 06/26/2019] [Accepted: 06/27/2019] [Indexed: 01/23/2023]
Abstract
The latest advances in both theory and experimental procedures on third-order/four-way and fourth-order/five-way calibration methods are discussed. This report is focused on excitation-emission (fluorescence and phosphorescence) matrices generation, employing different variables as the third data mode (time retention in chromatography, pH gradient, fluorescence/phosphorescence lifetime, kinetics, or other chemical treatments). Fully capitalizing on the second-order advantage, it has been possible to develop appealing analytical applications in spite of the complexity of the data. Extraction of the significant chemical information about the system under study as well as the individual abundance of the contributing constituents after proper higher-order data decomposition has allowed to analytical researchers performing quantitative analysis of complex samples. The experimental works reported up to the present are introduced and discussed in order to illustrate concepts. Throughout this work, the analytical benefits achieved by modeling third- and fourth-order data are exposed, attempting to contribute to the ongoing debate in the chemometric community regarding the existence and the true nature of the third-order advantage.
Collapse
Affiliation(s)
- Mirta R Alcaraz
- Laboratorio de Desarrollo Analítico y Quimiometría (LADAQ), Cátedra de Química Analítica I, Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral, Ciudad Universitaria, Santa Fe, S3000ZAA, Argentina; Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz 2290 CABA, C1425FQB, Argentina; Departamento de Química Inorgánica, Analítica y Química Física, INQUIMAE, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Intendente Güiraldes 2160, Ciudad Universitaria, Pabellón 2, C1428EGA, Buenos Aires, Argentina
| | - Olga Monago-Maraña
- Department of Analytical Chemistry, University of Extremadura, Badajoz, 06006, Spain; Research Institute on Water, Climate Change and Sustainability (IACYS), Badajoz, 06006, Spain
| | - Héctor C Goicoechea
- Laboratorio de Desarrollo Analítico y Quimiometría (LADAQ), Cátedra de Química Analítica I, Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral, Ciudad Universitaria, Santa Fe, S3000ZAA, Argentina; Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz 2290 CABA, C1425FQB, Argentina
| | - Arsenio Muñoz de la Peña
- Department of Analytical Chemistry, University of Extremadura, Badajoz, 06006, Spain; Research Institute on Water, Climate Change and Sustainability (IACYS), Badajoz, 06006, Spain.
| |
Collapse
|
6
|
Mikani M, Talaei S, Rahmanian R, Ahmadi P, Mahmoudi A. Sensitive electrochemical sensor for urea determination based on F-doped SnO2 electrode modified with ZnO-Fe3O4 nanoparticles transducer: Application in biological fluids. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.04.004] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
7
|
|
8
|
Yang Z, Liu T, Wang Y, Yuan Y, Shang F. Comparison of several third-order correction algorithms applied to fluorescence excitation-emission-sample data array: Interference-free determination of polycyclic aromatic hydrocarbons in water pollution. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2018; 205:381-390. [PMID: 30041124 DOI: 10.1016/j.saa.2018.07.045] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2018] [Revised: 07/12/2018] [Accepted: 07/15/2018] [Indexed: 06/08/2023]
Abstract
Interference-free determination of polycyclic aromatic hydrocarbons (PAHs) in water pollution is proposed based on third-order correction algorithms with quadrilinear component modeling applied to the constructed four way fluorescence excitation-emission-sample data array with higher accuracy and better predictive ability than second-order (three-dimension) correction. Alternating weighted residue constraint quadrilinear decomposition (AWRCQLD), quadrilinear parallel factor analysis (4-PARAFAC), alternate penalty quadrilinear decomposition (APQLD) and alternate penalty trilinear decomposition (APTLD) are applied to acenaphthene (ANA), naphthalene (NAP) and fluorene (FLU) respectively. Fulvic acid affects PAHs determination seriously in real-world situation, so it is simulated as an interfering agent. Excitation-emission fluorescence matrixes (EEMs) of PAHs are measured at different volumes of fulvic acid simulated different interference conditions, to construct a four-way data array. After the four-way spectra data is analyzed by AWRCQLD, 4-PARAFAC, and APQLD, three-way EEMs analyzed by APTLD, results show that, on the one hand, PAHs can be measured more accurately with four-way data combined with third-order calibration than lower-order. On the other hand, AWRCQLD algorithm can reflect the superiority of third-order advantage better with higher recovery rate and smaller root mean square error, than other third-order or second-order correction algorithms.
Collapse
Affiliation(s)
- Zhe Yang
- Measurement Technology and Instrument Key Lab of Hebei Province, Yanshan University, Qinhuangdao 066004, China
| | - Tingting Liu
- Measurement Technology and Instrument Key Lab of Hebei Province, Yanshan University, Qinhuangdao 066004, China; Vocational and Technical College of Liuzhou, Liuzhou 545000, China.
| | - Yutian Wang
- Measurement Technology and Instrument Key Lab of Hebei Province, Yanshan University, Qinhuangdao 066004, China
| | - Yuanyuan Yuan
- Measurement Technology and Instrument Key Lab of Hebei Province, Yanshan University, Qinhuangdao 066004, China
| | - Fengkai Shang
- Measurement Technology and Instrument Key Lab of Hebei Province, Yanshan University, Qinhuangdao 066004, China
| |
Collapse
|
9
|
Wu Q, Xie L, Xu H. Determination of toxigenic fungi and aflatoxins in nuts and dried fruits using imaging and spectroscopic techniques. Food Chem 2018; 252:228-242. [DOI: 10.1016/j.foodchem.2018.01.076] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2017] [Revised: 12/06/2017] [Accepted: 01/09/2018] [Indexed: 12/29/2022]
|
10
|
Dinç E, Ertekin ZC, Büker E. Multiway analysis methods applied to the fluorescence excitation-emission dataset for the simultaneous quantification of valsartan and amlodipine in tablets. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2017; 184:255-261. [PMID: 28514719 DOI: 10.1016/j.saa.2017.04.081] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2017] [Revised: 04/26/2017] [Accepted: 04/29/2017] [Indexed: 06/07/2023]
Abstract
In this study, excitation-emission matrix datasets, which have strong overlapping bands, were processed by using four different chemometric calibration algorithms consisting of parallel factor analysis, Tucker3, three-way partial least squares and unfolded partial least squares for the simultaneous quantitative estimation of valsartan and amlodipine besylate in tablets. In analyses, preliminary separation step was not used before the application of parallel factor analysis Tucker3, three-way partial least squares and unfolded partial least squares approaches for the analysis of the related drug substances in samples. Three-way excitation-emission matrix data array was obtained by concatenating excitation-emission matrices of the calibration set, validation set, and commercial tablet samples. The excitation-emission matrix data array was used to get parallel factor analysis, Tucker3, three-way partial least squares and unfolded partial least squares calibrations and to predict the amounts of valsartan and amlodipine besylate in samples. For all the methods, calibration and prediction of valsartan and amlodipine besylate were performed in the working concentration ranges of 0.25-4.50μg/mL. The validity and the performance of all the proposed methods were checked by using the validation parameters. From the analysis results, it was concluded that the described two-way and three-way algorithmic methods were very useful for the simultaneous quantitative resolution and routine analysis of the related drug substances in marketed samples.
Collapse
Affiliation(s)
- Erdal Dinç
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Tandoğan, 06100 Ankara, Turkey.
| | - Zehra Ceren Ertekin
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Tandoğan, 06100 Ankara, Turkey
| | - Eda Büker
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Tandoğan, 06100 Ankara, Turkey
| |
Collapse
|
11
|
Hu Y, Wu HL, Yin XL, Gu HW, Xiao R, Wang L, Fang H, Yu RQ. Interference-free spectrofluorometric quantification of aristolochic acid I and aristololactam I in five Chinese herbal medicines using chemical derivatization enhancement and second-order calibration methods. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2017; 175:229-238. [PMID: 28040573 DOI: 10.1016/j.saa.2016.12.030] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2016] [Revised: 12/12/2016] [Accepted: 12/19/2016] [Indexed: 06/06/2023]
Abstract
A rapid interference-free spectrofluorometric method combined with the excitation-emission matrix fluorescence and the second-order calibration methods based on the alternating penalty trilinear decomposition (APTLD) and the self-weighted alternating trilinear decomposition (SWATLD) algorithms, was proposed for the simultaneous determination of nephrotoxic aristolochic acid I (AA-I) and aristololactam I (AL-I) in five Chinese herbal medicines. The method was based on a chemical derivatization that converts the non-fluorescent AA-I to high-fluorescent AL-I, achieving a high sensitive and simultaneous quantification of the analytes. The variables of the derivatization reaction that conducted by using zinc powder in acetose methanol aqueous solution, were studied and optimized for best quantification results of AA-I and AL-I. The satisfactory results of AA-I and AL-I for the spiked recovery assay were achieved with average recoveries in the range of 100.4-103.8% and RMSEPs <0.78ngmL-1, which validate the accuracy and reliability of the proposed method. The contents of AA-I and AL-I in five herbal medicines obtained from the proposed method were also in good accordance with those of the validated LC-MS/MS method. In light of high sensitive fluorescence detection, the limits of detection (LODs) of AA-I and AL-I for the proposed method compare favorably with that of the LC-MS/MS method, with the LODs <0.35 and 0.29ngmL-1, respectively. The proposed strategy based on the APTLD and SWATLD algorithms by virtue of the "second-order advantage", can be considered as an attractive and green alternative for the quantification of AA-I and AL-I in complex herbal medicine matrices without any prior separations and clear-up processes.
Collapse
Affiliation(s)
- Yong Hu
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, People's Republic of China
| | - Hai-Long Wu
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, People's Republic of China.
| | - Xiao-Li Yin
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, People's Republic of China
| | - Hui-Wen Gu
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, People's Republic of China
| | - Rong Xiao
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, People's Republic of China
| | - Li Wang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, People's Republic of China
| | - Huan Fang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, People's Republic of China
| | - Ru-Qin Yu
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, People's Republic of China
| |
Collapse
|
12
|
Abstract
A road map is proposed for the selection of a multi-way calibration model according to the data properties.
Collapse
Affiliation(s)
- Graciela M. Escandar
- Departamento de Química Analítica
- Facultad de Ciencias Bioquímicas y Farmacéuticas
- Universidad Nacional de Rosario
- Instituto de Química de Rosario (IQUIR-CONICET)
- Rosario S2002LRK
| | - Alejandro C. Olivieri
- Departamento de Química Analítica
- Facultad de Ciencias Bioquímicas y Farmacéuticas
- Universidad Nacional de Rosario
- Instituto de Química de Rosario (IQUIR-CONICET)
- Rosario S2002LRK
| |
Collapse
|