1
|
Zhou Y, He B, Cao X, Xiao Y, Feng Q, Yang F, Xiao F, Geng X, Du Y. Remotely sensed estimates of long-term biochemical oxygen demand over Hong Kong marine waters using machine learning enhanced by imbalanced label optimisation. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 943:173748. [PMID: 38857793 DOI: 10.1016/j.scitotenv.2024.173748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 04/30/2024] [Accepted: 06/02/2024] [Indexed: 06/12/2024]
Abstract
In many coastal cities around the world, continuing water degradation threatens the living environment of humans and aquatic organisms. To assess and control the water pollution situation, this study estimated the Biochemical Oxygen Demand (BOD) concentration of Hong Kong's marine waters using remote sensing and an improved machine learning (ML) method. The scheme was derived from four ML algorithms (RBF, SVR, RF, XGB) and calibrated using a large amount (N > 1000) of in-situ BOD5 data. Based on labeled datasets with different preprocessing, i.e., the original BOD5, the log10(BOD5), and label distribution smoothing (LDS), three types of models were trained and evaluated. The results highlight the superior potential of the LDS-based model to improve BOD5 estimate by dealing with imbalanced training dataset. Additionally, XGB and RF outperformed RBF and SVR when the model was developed using log10(BOD5) or LDS(BOD5). Over two decades, the BOD5 concentration of Hong Kong marine waters in the autumn (Sep. to Nov.) shows a downward trend, with significant decreases in Deep Bay, Western Buffer, Victoria Harbour, Eastern Buffer, Junk Bay, Port Shelter, and the Tolo Harbour and Channel. Principal component analysis revealed that nutrient levels emerged as the predominant factor in Victoria Harbour and the interior of Deep Bay, while chlorophyll-related and physical parameters were dominant in Southern, Mirs Bay, Northwestern, and the outlet of Deep Bay. LDS provides a new perspective to improve ML-based water quality estimation by alleviating the imbalance in the labeled dataset. Overall, the remotely sensed BOD5 can offer insight into the spatial-temporal distribution of organic matter in Hong Kong coastal waters and valuable guidance for the pollution control.
Collapse
Affiliation(s)
- Yadong Zhou
- Key Laboratory for Environment and Disaster Monitoring and Evaluation of Hubei, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China
| | - Boayin He
- Key Laboratory for Environment and Disaster Monitoring and Evaluation of Hubei, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China.
| | - Xiaoyu Cao
- School of Geography and Ocean Science, Nanjing University, Nanjing 210023, China
| | - Yu Xiao
- Key Laboratory of Wetland Ecology and Environment, Northeast Institute of Geography and Agroecology, Chinese Academy of Sciences, Changchun 130102, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Qi Feng
- Key Laboratory for Environment and Disaster Monitoring and Evaluation of Hubei, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China
| | - Fan Yang
- Key Laboratory for Environment and Disaster Monitoring and Evaluation of Hubei, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Fei Xiao
- Key Laboratory for Environment and Disaster Monitoring and Evaluation of Hubei, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China
| | - Xueer Geng
- Key Laboratory for Environment and Disaster Monitoring and Evaluation of Hubei, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yun Du
- Key Laboratory for Environment and Disaster Monitoring and Evaluation of Hubei, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China
| |
Collapse
|
2
|
Perchikov R, Cheliukanov M, Plekhanova Y, Tarasov S, Kharkova A, Butusov D, Arlyapov V, Nakamura H, Reshetilov A. Microbial Biofilms: Features of Formation and Potential for Use in Bioelectrochemical Devices. BIOSENSORS 2024; 14:302. [PMID: 38920606 PMCID: PMC11201457 DOI: 10.3390/bios14060302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Revised: 06/03/2024] [Accepted: 06/05/2024] [Indexed: 06/27/2024]
Abstract
Microbial biofilms present one of the most widespread forms of life on Earth. The formation of microbial communities on various surfaces presents a major challenge in a variety of fields, including medicine, the food industry, shipping, etc. At the same time, this process can also be used for the benefit of humans-in bioremediation, wastewater treatment, and various biotechnological processes. The main direction of using electroactive microbial biofilms is their incorporation into the composition of biosensor and biofuel cells This review examines the fundamental knowledge acquired about the structure and formation of biofilms, the properties they have when used in bioelectrochemical devices, and the characteristics of the formation of these structures on different surfaces. Special attention is given to the potential of applying the latest advances in genetic engineering in order to improve the performance of microbial biofilm-based devices and to regulate the processes that take place within them. Finally, we highlight possible ways of dealing with the drawbacks of using biofilms in the creation of highly efficient biosensors and biofuel cells.
Collapse
Affiliation(s)
- Roman Perchikov
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, Tula 300012, Russia; (R.P.); (M.C.); (A.K.); (V.A.)
| | - Maxim Cheliukanov
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, Tula 300012, Russia; (R.P.); (M.C.); (A.K.); (V.A.)
| | - Yulia Plekhanova
- Federal Research Center (Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences), G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, Pushchino 142290, Russia; (Y.P.); (S.T.)
| | - Sergei Tarasov
- Federal Research Center (Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences), G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, Pushchino 142290, Russia; (Y.P.); (S.T.)
| | - Anna Kharkova
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, Tula 300012, Russia; (R.P.); (M.C.); (A.K.); (V.A.)
| | - Denis Butusov
- Computer-Aided Design Department, Saint Petersburg Electrotechnical University “LETI”, Saint Petersburg 197022, Russia;
| | - Vyacheslav Arlyapov
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, Tula 300012, Russia; (R.P.); (M.C.); (A.K.); (V.A.)
| | - Hideaki Nakamura
- Department of Liberal Arts, Tokyo University of Technology, 1404-1 Katakura, Hachioji 192-0982, Tokyo, Japan;
| | - Anatoly Reshetilov
- Federal Research Center (Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences), G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, Pushchino 142290, Russia; (Y.P.); (S.T.)
| |
Collapse
|
3
|
Aguilar-Torrejón JA, Balderas-Hernández P, Roa-Morales G, Barrera-Díaz CE, Rodríguez-Torres I, Torres-Blancas T. Relationship, importance, and development of analytical techniques: COD, BOD, and, TOC in water—An overview through time. SN APPLIED SCIENCES 2023. [DOI: 10.1007/s42452-023-05318-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023] Open
Abstract
AbstractAnalytical techniques to measure organic matter in water, such as Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD5), and Total Organic Carbon (TOC) are widely used. Modifications have been proposed to make them faster, more sensitive, and more environmentally friendly. The purpose of producing a review over some time is to show the changes made on the standardized methods of each of these techniques, and to highlight the relationship between them in the process of ascertaining organic matter in water. Modifications to techniques COD and BOD entail several factors that need to be considered, namely: time, miniaturization, sensitivity, use of environmentally friendly reagents. Changes to TOC are focused on detection systems. Despite the advantages obtained by the modified techniques, traditional methods continue to be widely used, in most cases due to the lack of standardization of the new methods.
Graphic Abstract
Collapse
|
4
|
Arlyapov VA, Plekhanova YV, Kamanina OA, Nakamura H, Reshetilov AN. Microbial Biosensors for Rapid Determination of Biochemical Oxygen Demand: Approaches, Tendencies and Development Prospects. BIOSENSORS 2022; 12:842. [PMID: 36290979 PMCID: PMC9599453 DOI: 10.3390/bios12100842] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 09/23/2022] [Accepted: 10/01/2022] [Indexed: 06/16/2023]
Abstract
One of the main indices of the quality of water is the biochemical oxygen demand (BOD). A little over 40 years have passed since the practical application of the first microbial sensor for the determination of BOD, presented by the Japanese professor Isao Karube. This time span has brought new knowledge to and practical developments in the use of a wide range of microbial cells based on BOD biosensors. At present, this field of biotechnology is becoming an independent discipline. The traditional BOD analysis (BOD5) has not changed over many years; it takes no less than 5 days to carry out. Microbial biosensors can be used as an alternative technique for assessing the BOD attract attention because they can reduce hundredfold the time required to measure it. The review examines the experience of the creation and practical application of BOD biosensors accumulated by the international community. Special attention is paid to the use of multiple cell immobilization methods, signal registration techniques, mediators and cell consortia contained in the bioreceptor. We consider the use of nanomaterials in the modification of analytical devices developed for BOD evaluation and discuss the prospects of developing new practically important biosensor models.
Collapse
Affiliation(s)
- Vyacheslav A. Arlyapov
- Laboratory of Biologically Active Compounds and Biocomposites, Federal State Budgetary Educational Establishment of Higher Education “Tula State University”, 300012 Tula, Russia
| | - Yulia V. Plekhanova
- Pushchino Center for Biological Research of the Russian Academy of Sciences, G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, 142290 Pushchino, Russia
| | - Olga A. Kamanina
- Laboratory of Biologically Active Compounds and Biocomposites, Federal State Budgetary Educational Establishment of Higher Education “Tula State University”, 300012 Tula, Russia
| | - Hideaki Nakamura
- Department of Liberal Arts, Tokyo University of Technology, 1404-1 Katakura, Hachioji, Tokyo 192-0982, Japan
| | - Anatoly N. Reshetilov
- Pushchino Center for Biological Research of the Russian Academy of Sciences, G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, 142290 Pushchino, Russia
| |
Collapse
|
5
|
A Universal Biofilm Reactor Sensor for the Determination of Biochemical Oxygen Demand of Different Water Areas. MOLECULES (BASEL, SWITZERLAND) 2022; 27:molecules27155046. [PMID: 35956996 PMCID: PMC9370119 DOI: 10.3390/molecules27155046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 08/02/2022] [Accepted: 08/05/2022] [Indexed: 11/16/2022]
Abstract
In this study, we developed a simple strategy to prepare a biofilm reactor (BFR) sensor for the universal biochemical oxygen demand (BOD) determination. The microorganisms in fresh water were domesticated by artificial seawater with different salinity gradients successively to prepare the BFR sensor. The prepared BFR sensor exhibits an efficient ability to degrade a variety of organic substances. The linear range of BOD determination by the BFR sensor is 1.0–10.0 mg/L−1 with a correlation coefficient of 0.9951. The detection limit is 0.30 mg/L according to three times of signal-to-noise ratio. What is more, the BFR sensor displayed excellent performances for the BOD determination of different water samples, including both fresh water and seawater. The 16S-rRNA gene sequencing technology was used to analyze the microbial species before and after the domestication. The results show that it is a general approach for the rapid BOD determination in different water samples.
Collapse
|
6
|
Lv H, Yang Q, Chen Y, Xu X, Liu C, Jia J. Determination of seawater biochemical oxygen demand based on in situ cultured biofilm reactor. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115872] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
7
|
Arlyapov VA, Yudina NY, Machulin AV, Alferov VA, Ponamoreva ON, Reshetilov AN. A Biosensor Based Microorganisms Immobilized in Layer-by-Layer Films for the Determination of Biochemical Oxygen Demand. APPL BIOCHEM MICRO+ 2021. [DOI: 10.1134/s0003683821010038] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
8
|
Ngoc LTB, Tu TA, Hien LTT, Linh DN, Tri N, Duy NPH, Cuong HT, Phuong PTT. Simple approach for the rapid estimation of BOD 5 in food processing wastewater. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2020; 27:20554-20564. [PMID: 32274695 DOI: 10.1007/s11356-020-08703-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Accepted: 03/31/2020] [Indexed: 06/11/2023]
Abstract
A simple approach was developed for the rapid and accurate estimation of 5-day biochemical oxygen demand (BOD5) in food processing wastewater. Immobilization of the natural microbial consortium that was collected from an aerobic compartment of a food processing wastewater treatment plant was simply performed by adhesion using a low-cost porous carrier. Pseudomonas aeruginosa, Bacillus cereus, and Streptomyces, whose salt-tolerance and ability to break down organic compounds have been widely reported, were found to be predominant. These microorganisms may cause an enhancement of the bioreactor response in the presence of sodium chloride. Consequently, a modified glucose-glutamic acid (GGA) calibration standard was proposed in which an appropriate amount of NaCl was added; this solution was found to be more effective in terms of accuracy and practicality than both conventional GGA and the synthetic wastewater recipe from the Organisation for Economic Cooperation and Development (OECD). The calibrated self-built packed-bed bioreactor exhibited good precision of 3% or less in predicting BOD5 in influent, which is similar to the performance of the most common commercial biochemical oxygen demand (BOD) bioreactors. There was a statistical agreement between the results obtained from this rapid BOD biosensor and the conventional methods, even when testing treated wastewater samples.
Collapse
Affiliation(s)
- Le Thi Bao Ngoc
- Ho Chi Minh City University of Science, 227 Nguyen Van Cu Street, District 5, Ho Chi Minh City, Vietnam
- Vietnam National University Ho Chi Minh City, Linh Trung Ward, Thu Duc District, Ho Chi Minh City, Vietnam
- Vietnam Academy of Science and Technology-Institute of Chemical Technology, 1 Mac Dinh Chi Street, District 1, Ho Chi Minh City, Vietnam
| | - Tran Anh Tu
- Vietnam National University Ho Chi Minh City, Linh Trung Ward, Thu Duc District, Ho Chi Minh City, Vietnam
| | - Luu Thi Thanh Hien
- Vietnam National University Ho Chi Minh City, Linh Trung Ward, Thu Duc District, Ho Chi Minh City, Vietnam
| | - Duong Nhat Linh
- Ho Chi Minh City Open University, 97 Vo Van Tan Street, District 3, Ho Chi Minh City, Vietnam
| | - Nguyen Tri
- Vietnam Academy of Science and Technology-Institute of Chemical Technology, 1 Mac Dinh Chi Street, District 1, Ho Chi Minh City, Vietnam
- Ho Chi Minh City Open University, 97 Vo Van Tan Street, District 3, Ho Chi Minh City, Vietnam
| | - Nguyen Phuc Hoang Duy
- Vietnam Academy of Science and Technology-Institute of Chemical Technology, 1 Mac Dinh Chi Street, District 1, Ho Chi Minh City, Vietnam
| | - Hoang Tien Cuong
- Vietnam Academy of Science and Technology-Institute of Chemical Technology, 1 Mac Dinh Chi Street, District 1, Ho Chi Minh City, Vietnam
| | - Pham Thi Thuy Phuong
- Vietnam Academy of Science and Technology-Institute of Chemical Technology, 1 Mac Dinh Chi Street, District 1, Ho Chi Minh City, Vietnam.
| |
Collapse
|
9
|
Pham TTP, Nguyen PHD, Nguyen TTV, Duong HTL. Self-build packed-bed bioreactor for rapid and effective BOD estimation. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2019; 26:25656-25667. [PMID: 31267402 DOI: 10.1007/s11356-019-05711-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2018] [Accepted: 06/07/2019] [Indexed: 06/09/2023]
Abstract
This work demonstrated a simple, low-cost, rapid, and effective biochemical oxygen demand (BOD) estimation system based on a packed-bed bioreactor that can be easily self-built on-site at a particular wastewater treatment plant for continuous monitoring of the influent and effluent. The use of natural microbial consortium that were collected from the target wastewater and immobilized on a cheap porous carrier simply by adhesion resulted in an acceptable accuracy of over 95%. The newly developed semi-continuous operating mode with peak-type signals was shown to be able to continuously estimate BOD at a high flow rate to overcome the flow dependence of the oxygen electrode, limit clogging issues, enhance the response time, and lower the limit of detection. The resulting packed-bed bioreactors could work continuously for 22 h with a coefficient of variance (CoV) of only 1.8% or for 13 h a day for several days with a maximum CoV of 1.4% and their response was observed to be stable over 80 consecutive measurements. They exhibited stable responses at a wide pH range of 6.5-8.5, which is also the recommended range for aerobic wastewater treatment, emphasizing the greater ease of use of natural microorganisms for BOD estimation.
Collapse
Affiliation(s)
- Thi Thuy Phuong Pham
- Institute of Chemical Technology, Vietnam Academy of Science and Technology, 1 Mac Dinh Chi Street, District 1, Ho Chi Minh City, Vietnam.
| | - Phuc Hoang Duy Nguyen
- Institute of Chemical Technology, Vietnam Academy of Science and Technology, 1 Mac Dinh Chi Street, District 1, Ho Chi Minh City, Vietnam
| | - Thi Thuy Van Nguyen
- Institute of Chemical Technology, Vietnam Academy of Science and Technology, 1 Mac Dinh Chi Street, District 1, Ho Chi Minh City, Vietnam
| | - Huynh Thanh Linh Duong
- Institute of Chemical Technology, Vietnam Academy of Science and Technology, 1 Mac Dinh Chi Street, District 1, Ho Chi Minh City, Vietnam
| |
Collapse
|
10
|
A Mediated BOD Biosensor Based on Immobilized B. Subtilis on Three-Dimensional Porous Graphene-Polypyrrole Composite. SENSORS 2017; 17:s17112594. [PMID: 29125543 PMCID: PMC5713028 DOI: 10.3390/s17112594] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2017] [Revised: 10/19/2017] [Accepted: 11/07/2017] [Indexed: 12/11/2022]
Abstract
We have developed a novel mediated biochemical oxygen demand (BOD) biosensor based on immobilized Bacillus subtilis (B. subtilis) on three-dimensional (3D) porous graphene-polypyrrole (rGO-PPy) composite. The 3D porous rGO-PPy composite was prepared using hydrothermal method following with electropolymerization. Then the 3D porous rGO-PPy composite was used as a support for immobilizing negatively charged B. subtilis denoted as rGO-PPy-B through coordination and electrostatic interaction. Further, the prepared rGO-PPy-B was used as a microbial biofilm for establishing a mediated BOD biosensor with ferricyanide as an electronic acceptor. The indirect determination of BOD was performed by electrochemical measuring ferrocyanide generated from a reduced ferricyanide mediator using interdigited ultramicroelectrode array (IUDA) as the working electrode. The experimental results suggested a good linear relationship between the amperometric responses and BOD standard concentrations from 4 to 60 mg/L, with a limit detection of 1.8 mg/L (S/N ≥ 3). The electrochemical measurement of real water samples showed a good agreement with the conventional BOD₅ method, and the good anti-interference as well as the long-term stability were well demonstrated, indicating that the proposed mediated BOD biosensor in this study holds a potential practical application of real water monitoring.
Collapse
|