1
|
Muramatsu H, Naka M, Ito S, Kawamura M. Analysis of HepG2 cell response to a wide concentration range of mitomycin C using a multichannel quartz crystal microbalance system with a microscope. Heliyon 2023; 9:e20047. [PMID: 37809730 PMCID: PMC10559775 DOI: 10.1016/j.heliyon.2023.e20047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 09/08/2023] [Accepted: 09/08/2023] [Indexed: 10/10/2023] Open
Abstract
The morphological response of HepG2 cells to mitomycin C was analyzed using a multichannel quartz crystal microbalance system equipped with a home-built movable microscope that enables the simultaneous acquisition of cell images and measurements of eight-channel quartz crystal microbalance. After 24 h of cell seeding, mitomycin C was injected into the culture medium. During the attachment process, the resonant frequency decreased, and the curves fitted well with the first-order lag response. Analysis of the response to mitomycin C revealed that the resonant frequency response curves varied with mitomycin C concentration. When the mitomycin C concentration was <10 μmol L-1, the delay time was observed before the increase in resonant frequency. When the mitomycin C concentration was extremely low, an additional decrease in resonant frequency was observed in the middle of the delay time that fitted well with the cumulative log-normal distribution curve. The resonant frequency response curves after the delay time fitted well with the cumulative log-normal distribution curves. The delay time and mean cumulative log-normal distribution time for the increase in resonant frequency correlated with the mitomycin C concentration; however, the mean time for the additional decrease in the resonant frequency did not show a statistically significant difference as a function of mitomycin C concentration. For mitomycin C concentrations of >20 μmol L-1, the response to the change in resonant frequency was rapid, and the response curves fitted well with the first-order lag response. The first-order lag response indicates that the response occurred simultaneously for all cells. The results showed that the time constant was independent of the tested mitomycin C concentration between 20 and 100 μmol L-1. These results suggested that different cell death processes occurred by mitomycin C. The findings of this study suggest that the system can be used to investigate cell death in adherent cells.
Collapse
Affiliation(s)
- Hiroshi Muramatsu
- School of Bioscience and Biotechnology, Tokyo University of Technology, 1401-1 Katakura, Hachioji, Tokyo 192-0982, Japan
| | - Masahiro Naka
- School of Bioscience and Biotechnology, Tokyo University of Technology, 1401-1 Katakura, Hachioji, Tokyo 192-0982, Japan
| | - Sae Ito
- School of Bioscience and Biotechnology, Tokyo University of Technology, 1401-1 Katakura, Hachioji, Tokyo 192-0982, Japan
| | - Maki Kawamura
- School of Bioscience and Biotechnology, Tokyo University of Technology, 1401-1 Katakura, Hachioji, Tokyo 192-0982, Japan
| |
Collapse
|
2
|
Comparison of cultured cell attachment on a temperature-responsive polymer, poly-L-lysine, and collagen using modeling curves and a thermal-controlled quartz crystal microbalance. J Biol Phys 2021; 47:117-129. [PMID: 33893599 DOI: 10.1007/s10867-021-09568-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Accepted: 04/07/2021] [Indexed: 10/21/2022] Open
Abstract
The characteristics of cultured cell attachment onto poly-L-lysine (PLL), collagen, and the thermoresponsive polymer poly(N-isopropylacrylamide) (PNIPAM) were studied using a quartz crystal microbalance (QCM). A QCM with microscope cameras enclosed in a Peltier chamber was developed to enable QCM measurements and microphotographic imaging to be conducted in a temperature-controlled CO2 incubator. Human hepatoma cell line HepG2 cells were cultured on the quartz crystals coated with PLL, collagen, and PNIPAM. Response curves of the resonant frequency of the quartz crystals during the cell attachment process were analyzed on the basis of the parameters of modeling curves fit to the experimentally obtained curves. Analysis of the fitting curves showed that the time constants of the first-lag response were 11 h for PLL, 16 h for collagen, and 38 h for PNIPAM and that the frequency change for the PNIPAM films was six times smaller than those for the PLL and collagen films. These findings were supported by photographic images showing wider cell spread on PLL and collagen than on PNIPAM. The response of cells on PNIPAM was measured during a thermal cycle from 37 to 20 °C to 37 °C. In the resonance frequency-resonance resistance (F-R) diagram, the slopes of ΔR/ΔF corresponding to the cell attachment process and those corresponding to the thermal cycling process differed; the positions in the F-R diagram also shifted to higher resonant frequencies after the thermal cycle. These results suggested that the mass effect decreased as a result of the weakening of the cell attachment strength by the thermal cycle because the molecular brushes of PNIPAM were disarranged.
Collapse
|
3
|
Zhang J, Zhang X, Wei X, Xue Y, Wan H, Wang P. Recent advances in acoustic wave biosensors for the detection of disease-related biomarkers: A review. Anal Chim Acta 2021; 1164:338321. [PMID: 33992219 DOI: 10.1016/j.aca.2021.338321] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Revised: 02/05/2021] [Accepted: 02/09/2021] [Indexed: 02/08/2023]
Abstract
In the past several decades, acoustic wave biosensors, as an emerging kind of biosensors, have been developed and widely used for the detection of mass, viscosity, conductivity and density. Varieties of applications have been explored such as medical diagnosis, drug screening, environmental monitoring, food analysis and biochemical assay. Among them, the detection of disease-related biomarkers based on acoustic sensors has aroused great research interest all over the world. In this review, the classification and characteristics of acoustic wave biosensors are briefly introduced. Then, some classical studies and recent advances in disease-related biomarker detection utilizing these biosensors are summarized and detailed, respectively. Here, the disease-related biomarkers mainly include antigens, small molecular proteins, cancer cells, viruses and VOCs. Finally, challenges and future trends of these typical acoustic wave biosensors are discussed. Compared with other reviews of acoustic wave sensors, this review highlights the great potential of typical acoustic wave biosensors for early disease screening and diagnosis compared with widely-used medical imaging. Moreover, they are integrated with other technologies for the design of multi-analyte, multi-parameter and intelligent devices, collecting more comprehensive information from biomarkers. This review provides a new perspective on the applications and optimization of acoustic wave biosensors to develop more reliable platforms for disease-related biomarker detection and disease diagnosis.
Collapse
Affiliation(s)
- Junyu Zhang
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China; State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Shanghai, 200050, China
| | - Xiaojing Zhang
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Xinwei Wei
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Yingying Xue
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Hao Wan
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China; State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Shanghai, 200050, China
| | - Ping Wang
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China; State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Shanghai, 200050, China.
| |
Collapse
|
4
|
Muramatsu H, Ito S, Alsaleem AHA. Monitoring and Modeling of Living Cell Responses in the Attachment Process and Reaction to the Antitumor Reagent Cisplatin Studied by a Quartz Crystal Microbalance Combined with a Microscope. Anal Chem 2020; 92:7907-7914. [PMID: 32347091 DOI: 10.1021/acs.analchem.0c01274] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The attachment process and response to an antitumor reagent for cultured cells were monitored with a quartz crystal microbalance (QCM) combined with a microscope. To fit the experimentally obtained curves of the resonant frequency, model equations of resonant frequency curves were built, and parameters of time constants and scale coefficients were determined. For the cell attachment process, a first-order lag response curve well fit the experimental curves. For the response to cisplatin, two response steps were observed in both QCM data and microscopic images, where the cells loosened in the first step and shrank in the second step. Resonant frequency responses for both processes were well fit by two logarithmic normal distribution functions. In addition, the dependence of the resonant frequency change on the cell number was also studied, and a cell-cell interaction model for attached cells was proposed to explain the saturation of the resonant frequency change in high density cell seeding.
Collapse
Affiliation(s)
- Hiroshi Muramatsu
- Graduate School of Bionics, Computer and Media Sciences, Tokyo University of Technology, 1401-1 Katakura, Hachioji, Tokyo 192-0982, Japan
| | - Sae Ito
- Graduate School of Bionics, Computer and Media Sciences, Tokyo University of Technology, 1401-1 Katakura, Hachioji, Tokyo 192-0982, Japan
| | - Abdullah Hussain A Alsaleem
- Graduate School of Bionics, Computer and Media Sciences, Tokyo University of Technology, 1401-1 Katakura, Hachioji, Tokyo 192-0982, Japan
| |
Collapse
|
5
|
Radiation-Activated Pre-Differentiated Retinal Tissue Monitored by Acoustic Wave Biosensor. SENSORS 2020; 20:s20092628. [PMID: 32380642 PMCID: PMC7248926 DOI: 10.3390/s20092628] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Revised: 04/29/2020] [Accepted: 05/02/2020] [Indexed: 11/17/2022]
Abstract
A thickness-shear mode acoustic wave biosensor operated within a flow-through system was used to examine the response of mouse retinal tissue to radiation. Control experiments conducted with respect to exposure of the bare gold electrodes of the device under various conditions of light intensity and bathing solution yielded reversible changes in resonant frequency (Fs) and motional resistance (Rm). The magnitude of transient changes was proportional to light intensity, but independent of solution type. These alterations in acoustic parameters were ascribed to acoustic coupling phenomena at the electrode-to-liquid interface. Pre-differentiated retina from mouse samples deposited on the thickness shear mode (TSM) electrode exposed to a high light intensity condition also exhibited reversible changes in both Fs and Rm, compared to control experiments involving a coating used to attach the tissue to the electrode. In this case, the radiation-instigated reversible responses for both acoustic parameters exhibited a reduction in magnitude. The changes are ascribed to the alteration in viscoelasticity of the retinal matrix on the TSM electrode surface. The precise biophysical mechanism responsible for the changes in Fs and Rm remains a challenge, given the complex make up of retinal tissue.
Collapse
|
6
|
Jandas PJ, Luo J, Quan A, Li C, Fu C, Fu YQ. Graphene oxide-Au nano particle coated quartz crystal microbalance biosensor for the real time analysis of carcinoembryonic antigen. RSC Adv 2020; 10:4118-4128. [PMID: 35492675 PMCID: PMC9049092 DOI: 10.1039/c9ra09963h] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Accepted: 12/24/2019] [Indexed: 12/13/2022] Open
Abstract
A label-free quartz crystal microbalance (QCM) biosensor was developed for the selective and real-time estimation of carcinoembryonic antigen (CEA) through the present study. Graphene oxide-Au nanoparticles (GO-AuNPs) was in situ synthesised on the surface of the QCM electrode and the antibody of CEA (monoclonal anti-CEA from mouse) was covalently immobilized on this layer as the bioreceptor for CEA. Mercaptoacetic acid-EDC-NHS reaction mechanism was used for anti-CEA immobilization. The effect of oxygen plasma treatment of the QCM electrode surface before bioreceptor preparation on the performance of the biosensor was tested and was found promising. CEA solutions with various concentrations were analysed using the bioreceptors to estimate the sensitivity and detection limit of the biosensor. The biosensors selectively recognized and captured CEA biomolecules with a detection limit of 0.06 and 0.09 ng mL-1 of CEA for oxygen plasma-treated (E2) and untreated (E1) bioreceptors, respectively. The sensitivity was estimated at 102 and 79 Hz, respectively, for E2 and E1. Clinical serum samples were analysed and the results were found in good agreement with the ELISA analysis. Long term stability was also found to be excellent. Langmuir adsorption isotherm was also conducted using the experimental results.
Collapse
Affiliation(s)
- P J Jandas
- Shenzhen Key Laboratory of Advanced Thin Films and Applications, College of Physics and Energy, Shenzhen University 518060 Shenzhen PR China
- Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen University 518060 Shenzhen PR China
| | - Jingting Luo
- Shenzhen Key Laboratory of Advanced Thin Films and Applications, College of Physics and Energy, Shenzhen University 518060 Shenzhen PR China
| | - Aojie Quan
- Shenzhen Key Laboratory of Advanced Thin Films and Applications, College of Physics and Energy, Shenzhen University 518060 Shenzhen PR China
| | - Chong Li
- Shenzhen Key Laboratory of Advanced Thin Films and Applications, College of Physics and Energy, Shenzhen University 518060 Shenzhen PR China
| | - Chen Fu
- Shenzhen Key Laboratory of Advanced Thin Films and Applications, College of Physics and Energy, Shenzhen University 518060 Shenzhen PR China
| | - Y Q Fu
- Faculty of Engineering and Environment, Northumbria University Newcastle upon Tyne NE1 8ST UK
| |
Collapse
|
7
|
Tonda-Turo C, Carmagnola I, Ciardelli G. Quartz Crystal Microbalance With Dissipation Monitoring: A Powerful Method to Predict the in vivo Behavior of Bioengineered Surfaces. Front Bioeng Biotechnol 2018; 6:158. [PMID: 30425985 PMCID: PMC6218436 DOI: 10.3389/fbioe.2018.00158] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2018] [Accepted: 10/10/2018] [Indexed: 12/29/2022] Open
Abstract
The Quartz Crystal Microbalance with dissipation monitoring (QCM-D) is a tool to measure mass and viscosity in processes occurring at or near surfaces, or within thin films. QCM-D is able to detect extremely small chemical, mechanical, and electrical changes taking place on the sensor surface and to convert them into electrical signals which can be investigated to study dynamic process. Surface nanotopography and chemical composition are of pivotal importance in biomedical applications since interactions of medical devices with the physiological environment are mediated by surface features. This review is intended to provide readers with an up-to-date summary of QCM-D applications in the study of cell behavior and to discuss the future trends for the use of QCM-D as a high-throughput method to study cell/surface interactions overcoming the current challenges in the design of biomedical devices.
Collapse
Affiliation(s)
- Chiara Tonda-Turo
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.,POLITO BIOMedLAB, Politecnico di Torino, Turin, Italy
| | - Irene Carmagnola
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.,POLITO BIOMedLAB, Politecnico di Torino, Turin, Italy
| | - Gianluca Ciardelli
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.,POLITO BIOMedLAB, Politecnico di Torino, Turin, Italy.,Department for Materials and Devices of the National Research Council, Institute for the Chemical and Physical Processes (CNR-IPCF UOS), Pisa, Italy
| |
Collapse
|
8
|
Bianco M, Vergara D, De Domenico S, Maffia M, Gaballo A, Arima V. Quartz Crystal Microbalance as Cell-Based Biosensor to Detect and Study Cytoskeletal Alterations and Dynamics. Biotechnol J 2018; 13:e1700699. [PMID: 29663725 DOI: 10.1002/biot.201700699] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Revised: 03/09/2018] [Indexed: 02/04/2023]
Abstract
Several techniques can be used to monitor cell dynamism after a perturbation. Among these, Quartz Crystal Microbalance with Dissipation Monitoring (QCM-D) offers the great advantage to study the mechanical properties of cells in real-time and with a great sensitivity. Here, we used QCM-D to investigate the effects of two cytoskeleton-targeting agents, cytochalasin D (CytoD) and Y27632, on human MCF-7 cells. Cell adhesion on the sensor surface, crucial for in-flow experiments, was obtained by covalent adsorption of a fibronectin (FN) film, an extracellular matrix (ECM) protein. Direct analysis of MCF-7 cells on FN-coated sensor, shows a specific cellular response that was revealed and quantified by QCM-D after drugs exposure. Notably, upon treatment with Y27632, we observed a two-regime dissipation behavior that we associated with specific modifications of actin filaments and signaling proteins providing a link between biophysical and molecular mechanisms. Overall, this approach opens new opportunities for studying cellular response to mechanical cues in different biological conditions.
Collapse
Affiliation(s)
- Monica Bianco
- CNR-NANOTEC, Institute of Nanotechnology c/o Campus Ecotekne, Lecce, Italy
| | - Daniele Vergara
- Department of Biological and Environmental Sciences and Technologies, University of Salento, Lecce, Italy.,Laboratory of Clinical Proteo-mics, "Giovanni Paolo II" Hospital, ASL-Lecce, Italy
| | - Stefania De Domenico
- Biotecgen, c/o Department of Biological and Environmental Sciences and Technologies, Lecce, Italy.,Institute of Sciences of Food Production, National Research Council, Lecce, Italy
| | - Michele Maffia
- Department of Biological and Environmental Sciences and Technologies, University of Salento, Lecce, Italy.,Laboratory of Clinical Proteo-mics, "Giovanni Paolo II" Hospital, ASL-Lecce, Italy
| | - Antonio Gaballo
- CNR-NANOTEC, Institute of Nanotechnology c/o Campus Ecotekne, Lecce, Italy
| | - Valentina Arima
- CNR-NANOTEC, Institute of Nanotechnology c/o Campus Ecotekne, Lecce, Italy
| |
Collapse
|
9
|
Quartz crystal microbalance with dissipation as a biosensing platform to evaluate cell–surface interactions of osteoblast cells. Biointerphases 2018; 13:011001. [DOI: 10.1116/1.5000752] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|