1
|
Zhu R, Figueroa-Miranda G, Zhou L, Hu Z, Lenyk B, Ingebrandt S, Offenhäusser A, Mayer D. A Combined Plasmonic and Electrochemical Aptasensor Based on Gold Nanopit Arrays for the Detection of Human Serum Albumin. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:2374. [PMID: 37630959 PMCID: PMC10458775 DOI: 10.3390/nano13162374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Revised: 08/04/2023] [Accepted: 08/17/2023] [Indexed: 08/27/2023]
Abstract
Electrochemical and optical platforms are commonly employed in designing biosensors. However, one signal readout can easily lead to inaccuracies due to the effect of nonstandard test procedures, different operators, and experimental environments. We have developed a dual-signal protocol that combined two transducer principles in one aptamer-based biosensor by simultaneously performing electrochemical- and extraordinary optical transmission (EOT)-based plasmonic detection using gold nanopit arrays (AuNpA). Compared with full hole structures, we found that nanopits, that did not fully penetrate the gold film, not only exhibited a better plasmonic bandwidth and refractive index sensitivity both in the finite-difference time-domain simulation and in experiments by shielding the gold/quartz mode but also enlarged the electrochemical active surface area. Therefore, the periodic non-fully penetrating AuNpA were modified with ferrocene-labeled human serum albumin aptamer receptors. The formation of the receptor layer and human serum albumin binding complex induced a conformational change, which resulted in variation in the electron transfer between the electro-active ferrocene units and the AuNpA surface. Simultaneously, the binding event caused a surface plasmon polaritons wavelength shift corresponding to a change in the surface refractive index. Interestingly, although both transducers recorded the same binding process, they led to different limits of detection, dynamic ranges, and sensitivities. The electrochemical transducer showed a dynamic detection range from 1 nM to 600 μM, while the optical transducer covered high concentrations from 100 μM to 600 μM. This study not only provides new insights into the design of plasmonic nanostructures but also potentially opens an exciting avenue for dual-signal disease diagnosis and point-of-care testing applications.
Collapse
Affiliation(s)
- Ruifeng Zhu
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
- Institute of Materials in Electrical Engineering 1, RWTH Aachen University, 52074 Aachen, Germany
| | - Gabriela Figueroa-Miranda
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
| | - Lei Zhou
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
| | - Ziheng Hu
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
| | - Bohdan Lenyk
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
- Department of Physics, University of Konstanz, 78457 Konstanz, Germany
| | - Sven Ingebrandt
- Institute of Materials in Electrical Engineering 1, RWTH Aachen University, 52074 Aachen, Germany
| | - Andreas Offenhäusser
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
| | - Dirk Mayer
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
| |
Collapse
|
2
|
Shalaby K, Alghamdi S, Gamal M, Elhalim LMA, Tony RM. A validated LC–MS/MS method for analysis of Cabergoline in human plasma with its implementation in a bioequivalent study: investigation of method greenness. BMC Chem 2022; 16:71. [PMID: 36153557 PMCID: PMC9509579 DOI: 10.1186/s13065-022-00862-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 08/25/2022] [Indexed: 12/03/2022] Open
Abstract
Cabergoline (CAB) is effective prolactin lowering drug. Evaluation of the bioequivalence for the new test product (0.5 mg CAB film-coated tablets) in Egypt is strongly needed for approval of the drug by the official health authority. Therefore, a highly sensitive and rapid (LC–MS/MS) method was validated for CAB analysis in human plasma. CAB was extracted from plasma via diethyl ether using Quetiapine (QUE) as an internal standard. Multiple reaction monitoring (MRM) in positive ion mode was used, m/z 452.3 → 381.2 for CAB and 384.2 → 253.1 for QUE. Separation was accomplished on a reversed-phase C18. FDA procedures for the bio-analytical method were followed. The method was used in the bioequivalence study to compare the test product (0.5 mg CAB) versus Dostinex tablets, on 24 healthy Egyptian volunteers. The total analysis time was 5.5 min for each sample which permits analysis of various samples per day. The linearity range was from 2.00 to 200.00 pg/mL for CAB. LOD and LOQ were found to be 0.5 and 1.6 pg/mL, respectively. The final greenness numerical value was 0.63 using AGREE tool. The results of pharmacokinetic parameter Tmax were 2.17, and 2.33 h; for test and reference products, respectively. The generic formulation of test product is considered bioequivalent to the reference product Dostinex 0.5 mg tablets and satisfies the requirements of the Egyptian market. The merits of the method over the previous published methods are low cost; availability of cheap internal standard; rapidness; use of acetonitrile-free solvents mobile phase.
Collapse
|
3
|
Jalalvand AR. Chemometrics assisted-electrochemical investigation of the binding and inhibition of calcineurin by tacrolimus: A combinatorial study. SENSING AND BIO-SENSING RESEARCH 2021. [DOI: 10.1016/j.sbsr.2021.100459] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
4
|
Developing an interesting electrochemical biosensing system from an enzyme inhibition study: Binding, inhibition and determination of catalase by ascorbate. SENSING AND BIO-SENSING RESEARCH 2020. [DOI: 10.1016/j.sbsr.2020.100383] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
|
5
|
Jalalvand AR. Four-dimensional voltammetry: An efficient strategy for simultaneous determination of ascorbic acid and uric acid in the presence of dopamine as uncalibrated interference. SENSING AND BIO-SENSING RESEARCH 2020. [DOI: 10.1016/j.sbsr.2020.100330] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
|