1
|
Aleksanyan M, Sayunts A, Shahkhatuni G, Simonyan Z, Kasparyan H, Kopecký D. Room Temperature Detection of Hydrogen Peroxide Vapor by Fe 2O 3:ZnO Nanograins. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 13:nano13010120. [PMID: 36616029 PMCID: PMC9824716 DOI: 10.3390/nano13010120] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 12/19/2022] [Accepted: 12/22/2022] [Indexed: 05/28/2023]
Abstract
In this report, a Fe2O3:ZnO sputtering target and a nanograins-based sensor were developed for the room temperature (RT) detection of hydrogen peroxide vapor (HPV) using the solid-state reaction method and the radio frequency (RF) magnetron sputtering technique, respectively. The characterization of the synthesized sputtering target and the obtained nanostructured film was carried out by scanning electron microscopy (SEM), transmission electron microscopy (TEM), and energy-dispersive X-ray (EDX) analyses. The SEM and TEM images of the film revealed its homogeneous granular structure, with a grain size of 10-30 nm and an interplanar spacing of Fe2O3 and ZnO, respectively. EDX spectroscopy presented the real concentrations of Zn in the target material and in the film (21.2 wt.% and 19.4 wt.%, respectively), with a uniform distribution of O, Al, Zn, and Fe elements in the e-mapped images of the Fe2O3:ZnO film. The gas sensing behavior was investigated in the temperature range of 25-250 °C with regards to the 1.5-56 ppm HPV concentrations, with and without ultraviolet (UV) irradiation. The presence of UV light on the Fe2O3:ZnO surface at RT reduced a low detection limit from 3 ppm to 1.5 ppm, which corresponded to a response value of 12, with the sensor's response and recovery times of 91 s and 482 s, respectively. The obtained promising results are attributed to the improved characteristics of the Fe2O3:ZnO composite material, which will enable its use in multifunctional sensor systems and medical diagnostic devices.
Collapse
Affiliation(s)
- Mikayel Aleksanyan
- Center of Semiconductor Devices and Nanotechnologies, Yerevan State University, Yerevan 0025, Armenia
| | - Artak Sayunts
- Center of Semiconductor Devices and Nanotechnologies, Yerevan State University, Yerevan 0025, Armenia
| | - Gevorg Shahkhatuni
- Center of Semiconductor Devices and Nanotechnologies, Yerevan State University, Yerevan 0025, Armenia
| | - Zarine Simonyan
- Center of Semiconductor Devices and Nanotechnologies, Yerevan State University, Yerevan 0025, Armenia
| | - Hayk Kasparyan
- Department of Computer and Control Engineering, Faculty of Chemical Engineering, University of Chemistry and Technology, 166 28 Prague, Czech Republic
| | - Dušan Kopecký
- Department of Computer and Control Engineering, Faculty of Chemical Engineering, University of Chemistry and Technology, 166 28 Prague, Czech Republic
| |
Collapse
|
2
|
Ahmad K, Kim H. Fabrication of Nitrogen-Doped Reduced Graphene Oxide Modified Screen Printed Carbon Electrode (N-rGO/SPCE) as Hydrogen Peroxide Sensor. NANOMATERIALS 2022; 12:nano12142443. [PMID: 35889667 PMCID: PMC9324769 DOI: 10.3390/nano12142443] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2022] [Revised: 07/05/2022] [Accepted: 07/14/2022] [Indexed: 12/04/2022]
Abstract
In recent years, the electrochemical sensing approach has attracted electrochemists because of its excellent detection process, simplicity, high sensitivity, cost-effectiveness, and high selectivity. In this study, we prepared nitrogen doped reduced graphene oxide (N-rGO) and characterized it using various advanced techniques such as XRD, SEM, EDX, Raman, and XPS. Furthermore, we modified the active surface of a screen printed carbon electrode (SPCE) via the drop-casting of N-rGO. This modified electrode (N-rGO/SPCE) exhibited an excellent detection limit (LOD) of 0.83 µM with a decent sensitivity of 4.34 µAµM−1cm−2 for the detection of hydrogen peroxide (H2O2). In addition, N-rGO/SPCE also showed excellent selectivity, repeatability, and stability for the sensing of H2O2. Real sample investigations were also carried out that showed decent recovery.
Collapse
|
3
|
Singh A, Sharma A, Arya S. Human sweat-based wearable glucose sensor on cotton fabric for real-time monitoring. J Anal Sci Technol 2022. [DOI: 10.1186/s40543-022-00320-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023] Open
Abstract
AbstractIn this work, a human sweat-based wearable sensor for real-time glucose monitoring has been fabricated on a cotton substrate after treating it with a two-step polymerization of pyrrole. The pyrrole-treated fabric was coated with solution of copper sulphate pentahydrate to grow Cu layer. The cotton/pyrrole/Cu fabric was treated with the solutions of copper acetate and manganese acetate to form Cu–Mn transition-metal alloy via electrochemical deposition technique. Results indicate that the developed sensor is reliable with glucose detection limit of 125 µM and 378 µM. In addition, the sensor output ranged between 50 and 400 µM glucose with coefficient of correlation, R2 = 0.983, indicating a linear range of output current. The sensor's response is not significantly affected by interferents. The developed sensor is also validated on human sweat with satisfactory results.
Collapse
|
4
|
Current progress in organic–inorganic hetero-nano-interfaces based electrochemical biosensors for healthcare monitoring. Coord Chem Rev 2022. [DOI: 10.1016/j.ccr.2021.214282] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
5
|
Synthesis of Rod-like NiO–Co3O4 Composites for Sensitive Electrochemical Detection of Hydrogen Peroxide. JOURNAL OF ANALYSIS AND TESTING 2021. [DOI: 10.1007/s41664-021-00202-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
6
|
Gričar E, Kalcher K, Genorio B, Kolar M. Highly Sensitive Amperometric Detection of Hydrogen Peroxide in Saliva Based on N-Doped Graphene Nanoribbons and MnO 2 Modified Carbon Paste Electrodes. SENSORS 2021; 21:s21248301. [PMID: 34960395 PMCID: PMC8707399 DOI: 10.3390/s21248301] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 12/06/2021] [Accepted: 12/10/2021] [Indexed: 11/27/2022]
Abstract
Four different graphene-based nanomaterials (htGO, N-htGO, htGONR, and N-htGONR) were synthesized, characterized, and used as a modifier of carbon paste electrode (CPE) in order to produce a reliable, precise, and highly sensitive non-enzymatic amperometric hydrogen peroxide sensor for complex matrices. CPE, with their robustness, reliability, and ease of modification, present a convenient starting point for the development of new sensors. Modification of CPE was optimized by systematically changing the type and concentration of materials in the modifier and studying the prepared electrode surface by cyclic voltammetry. N-htGONR in combination with manganese dioxide (1:1 ratio) proved to be the most appropriate material for detection of hydrogen peroxide in pharmaceutical and saliva matrices. The developed sensor exhibited a wide linear range (1.0–300 µM) and an excellent limit of detection (0.08 µM) and reproducibility, as well as high sensitivity and stability. The sensor was successfully applied to real sample analysis, where the recovery values for a commercially obtained pharmaceutical product were between 94.3% and 98.0%. Saliva samples of a user of the pharmaceutical product were also successfully analyzed.
Collapse
Affiliation(s)
- Ema Gričar
- Department of Chemistry and Biochemistry, Faculty of Chemistry and Chemical Technology, University of Ljubljana, Večna pot 113, 1000 Ljubljana, Slovenia;
| | - Kurt Kalcher
- Department of Analytical Chemistry, Insistute of Chemistry, University of Graz, Universitätsplatz 1, 8020 Graz, Austria;
| | - Boštjan Genorio
- Department of Chemical Engineering and Technical Safety, Faculty of Chemistry and Chemical Technology, University of Ljubljana, Večna pot 113, 1000 Ljubljana, Slovenia
- Correspondence: (B.G.); (M.K.)
| | - Mitja Kolar
- Department of Chemistry and Biochemistry, Faculty of Chemistry and Chemical Technology, University of Ljubljana, Večna pot 113, 1000 Ljubljana, Slovenia;
- Correspondence: (B.G.); (M.K.)
| |
Collapse
|
7
|
Nontipichet N, Khumngern S, Choosang J, Thavarungkul P, Kanatharana P, Numnuam A. An enzymatic histamine biosensor based on a screen-printed carbon electrode modified with a chitosan-gold nanoparticles composite cryogel on Prussian blue-coated multi-walled carbon nanotubes. Food Chem 2021; 364:130396. [PMID: 34167007 DOI: 10.1016/j.foodchem.2021.130396] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 06/12/2021] [Accepted: 06/14/2021] [Indexed: 01/10/2023]
Abstract
A histamine biosensor was developed based on a screen-printed carbon electrode modified with Prussian blue (PB) electrodeposited on multi-walled carbon nanotubes covered with a macroporous layer of chitosan-gold nanoparticles composite cryogel (CS-AuNPs Cry). With its high specific surface area and conductivity, CS-AuNPs Cry proved an excellent supporting material for diamine oxidase (DAO) immobilization. PB acted as a redox mediator to promote electron transfer between hydrogen peroxide and the electrode surface. The PB reduction current was measured during the hydrogen peroxide-releasing oxidation of histamine catalyzed by DAO. The proposed biosensor displayed two linear ranges: 2.50-125.0 µmol L-1 and 125.0-400.0 µmol L-1. The limit of detection was 1.81 µmol L-1. Reproducibility was good (RSD = 5.46%), operational stability high, long-term stability excellent, and selectivity good. The biosensor determined histamine levels in fish and shrimps with satisfactory recoveries, and the obtained results agreed with those obtained by ELISA.
Collapse
Affiliation(s)
- Natha Nontipichet
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand
| | - Suntisak Khumngern
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand
| | - Jittima Choosang
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand
| | - Panote Thavarungkul
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand
| | - Proespichaya Kanatharana
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand
| | - Apon Numnuam
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand.
| |
Collapse
|
8
|
Trujillo RM, Barraza DE, Zamora ML, Cattani-Scholz A, Madrid RE. Nanostructures in Hydrogen Peroxide Sensing. SENSORS 2021; 21:s21062204. [PMID: 33801140 PMCID: PMC8004286 DOI: 10.3390/s21062204] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 03/15/2021] [Accepted: 03/16/2021] [Indexed: 01/31/2023]
Abstract
In recent years, several devices have been developed for the direct measurement of hydrogen peroxide (H2O2), a key compound in biological processes and an important chemical reagent in industrial applications. Classical enzymatic biosensors for H2O2 have been recently outclassed by electrochemical sensors that take advantage of material properties in the nano range. Electrodes with metal nanoparticles (NPs) such as Pt, Au, Pd and Ag have been widely used, often in combination with organic and inorganic molecules to improve the sensing capabilities. In this review, we present an overview of nanomaterials, molecules, polymers, and transduction methods used in the optimization of electrochemical sensors for H2O2 sensing. The different devices are compared on the basis of the sensitivity values, the limit of detection (LOD) and the linear range of application reported in the literature. The review aims to provide an overview of the advantages associated with different nanostructures to assess which one best suits a target application.
Collapse
Affiliation(s)
- Ricardo Matias Trujillo
- Laboratorio de Medios e Interfases (LAMEIN), DBI, FACET, Universidad Nacional de Tucumán, Av. Independencia 1800, 4000 Tucumán, Argentina; (R.M.T.); (D.E.B.); (M.L.Z.)
- Instituto Superior de Investigaciones Biológicas (INSIBIO), CONICET, Chacabuco 461, 4000 Tucumán, Argentina
| | - Daniela Estefanía Barraza
- Laboratorio de Medios e Interfases (LAMEIN), DBI, FACET, Universidad Nacional de Tucumán, Av. Independencia 1800, 4000 Tucumán, Argentina; (R.M.T.); (D.E.B.); (M.L.Z.)
- Instituto Superior de Investigaciones Biológicas (INSIBIO), CONICET, Chacabuco 461, 4000 Tucumán, Argentina
| | - Martin Lucas Zamora
- Laboratorio de Medios e Interfases (LAMEIN), DBI, FACET, Universidad Nacional de Tucumán, Av. Independencia 1800, 4000 Tucumán, Argentina; (R.M.T.); (D.E.B.); (M.L.Z.)
- Instituto Superior de Investigaciones Biológicas (INSIBIO), CONICET, Chacabuco 461, 4000 Tucumán, Argentina
| | - Anna Cattani-Scholz
- Walter Schottky Institute and Physics Department, Technical University of Munich, Am Coulombwall 4, 85748 Garching, Germany
- Correspondence: (A.C.-S.); (R.E.M.)
| | - Rossana Elena Madrid
- Laboratorio de Medios e Interfases (LAMEIN), DBI, FACET, Universidad Nacional de Tucumán, Av. Independencia 1800, 4000 Tucumán, Argentina; (R.M.T.); (D.E.B.); (M.L.Z.)
- Instituto Superior de Investigaciones Biológicas (INSIBIO), CONICET, Chacabuco 461, 4000 Tucumán, Argentina
- Correspondence: (A.C.-S.); (R.E.M.)
| |
Collapse
|