1
|
Gautam S, Osman AFI, Richeson D, Gholami S, Manandhar B, Alam S, Song WY. Attention 3D U-NET for dose distribution prediction of high-dose-rate brachytherapy of cervical cancer: Direction modulated brachytherapy tandem applicator. Med Phys 2024. [PMID: 38830129 DOI: 10.1002/mp.17238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 03/27/2024] [Accepted: 05/21/2024] [Indexed: 06/05/2024] Open
Abstract
BACKGROUND Direction Modulated Brachytherapy (DMBT) enables conformal dose distributions. However, clinicians may face challenges in creating viable treatment plans within a fast-paced clinical setting, especially for a novel technology like DMBT, where cumulative clinical experience is limited. Deep learning-based dose prediction methods have emerged as effective tools for enhancing efficiency. PURPOSE To develop a voxel-wise dose prediction model using an attention-gating mechanism and a 3D UNET for cervical cancer high-dose-rate (HDR) brachytherapy treatment planning with DMBT six-groove tandems with ovoids or ring applicators. METHODS A multi-institutional cohort of 122 retrospective clinical HDR brachytherapy plans treated to a prescription dose in the range of 4.8-7.0 Gy/fraction was used. A DMBT tandem model was constructed and incorporated onto a research version of BrachyVision Treatment Planning System (BV-TPS) as a 3D solid model applicator and retrospectively re-planned all cases by seasoned experts. Those plans were randomly divided into 64:16:20 as training, validating, and testing cohorts, respectively. Data augmentation was applied to the training and validation sets to increase the size by a factor of 4. An attention-gated 3D UNET architecture model was developed to predict full 3D dose distributions based on high-risk clinical target volume (CTVHR) and organs at risk (OARs) contour information. The model was trained using the mean absolute error loss function, Adam optimization algorithm, a learning rate of 0.001, 250 epochs, and a batch size of eight. In addition, a baseline UNET model was trained similarly for comparison. The model performance was evaluated on the testing dataset by analyzing the outcomes in terms of mean dose values and derived dose-volume-histogram indices from 3D dose distributions and comparing the generated dose distributions against the ground-truth dose distributions using dose statistics and clinically meaningful dosimetric indices. RESULTS The proposed attention-gated 3D UNET model showed competitive accuracy in predicting 3D dose distributions that closely resemble the ground-truth dose distributions. The average values of the mean absolute errors were 1.82 ± 29.09 Gy (vs. 6.41 ± 20.16 Gy for a baseline UNET) in CTVHR, 0.89 ± 1.25 Gy (vs. 0.94 ± 3.96 Gy for a baseline UNET) in the bladder, 0.33 ± 0.67 Gy (vs. 0.53 ± 1.66 Gy for a baseline UNET) in the rectum, and 0.55 ± 1.57 Gy (vs. 0.76 ± 2.89 Gy for a baseline UNET) in the sigmoid. The results showed that the mean absolute error (MAE) for the bladder, rectum, and sigmoid were 0.22 ± 1.22 Gy (3.62%) (p = 0.015), 0.21 ± 1.06 Gy (2.20%) (p = 0.172), and -0.03 ± 0.54 Gy (1.13%) (p = 0.774), respectively. The MAE for D90, V100%, and V150% of the CTVHR were 0.46 ± 2.44 Gy (8.14%) (p = 0.018), 0.57 ± 11.25% (5.23%) (p = 0.283), and -0.43 ± 19.36% (4.62%) (p = 0.190), respectively. The proposed model needs less than 5 s to predict a full 3D dose distribution of 64 × 64 × 64 voxels for any new patient plan, thus making it sufficient for near real-time applications and aiding with decision-making in the clinic. CONCLUSIONS Attention gated 3D-UNET model demonstrated a capability in predicting voxel-wise dose prediction, in comparison to 3D UNET, for DMBT intracavitary brachytherapy planning. The proposed model could be used to obtain dose distributions for near real-time decision-making before DMBT planning and quality assurance. This will guide future automated planning, making the workflow more efficient and clinically viable.
Collapse
Affiliation(s)
- Suman Gautam
- Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA
| | | | - Dylan Richeson
- Department of Radiation Oncology, Inova Schar Cancer Institute, Fairfax, Virginia, USA
| | - Somayeh Gholami
- Department of Radiation Oncology, University of Utah, Salt Lake City, Utah, USA
| | - Binod Manandhar
- Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Sharmin Alam
- Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA
| | - William Y Song
- Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA
| |
Collapse
|
2
|
Funderud M, Hoem IS, Guleng MAD, Eidem M, Almberg SS, Alsaker MD, Ståhl-Kornerup J, Frengen J, Marthinsen ABL. Script-based automatic radiotherapy planning for cervical cancer. Acta Oncol 2023; 62:1798-1807. [PMID: 37881003 DOI: 10.1080/0284186x.2023.2267171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Accepted: 10/01/2023] [Indexed: 10/27/2023]
Abstract
BACKGROUND This study aimed to develop fully automated script-based radiotherapy treatment plans for cervical cancer patients, and evaluate them against clinically accepted plans, as validation before clinical implementation. MATERIAL AND METHODS In this retrospective planning study, treatment plans for 25 locally advanced cervical cancer (LACC) patients with up to three dose levels were included. Fully automated plans were created using an in-house developed Python script in RayStation, and compared to clinically accepted manually made plans. Quantitatively, relevant dose statistics were compared, and average dose volume histograms (DVHs) were analyzed. Qualitatively, a blinded plan comparison was conducted between the clinical and automatic plans. The accuracy of treatment plan delivery was verified with the Delta4 Phantom+. RESULTS The quantitative evaluation showed that target coverage was acceptable for all the automatic and clinical plans. The automatic plans were significantly more conformal than the clinical plans; median of 1.03 vs. 1.12. Mean doses to almost all organs at risk (OARs) were reduced in the automatic plans, with a median reduction of between 0.6 Gy and 1.9 Gy. In the blinded plan comparison, the automatic plans were the preferred plans or of equal quality as the clinical plans in 99% of the cases. In addition, plan delivery was excellent, with a mean gamma passing rate of 99.8%. Complete script-based plans were generated in 30-45 min; about four to ten times faster than manually made plans. CONCLUSION The automatic plans had acceptable target coverage, lower doses to almost all OARs, more conformal dose distributions, and were predominantly preferred by the clinicians. Based on these results, our institution has implemented the script for clinical use.
Collapse
Affiliation(s)
- Marit Funderud
- Department of Radiotherapy, St. Olavs Hospital, Trondheim, Norway
| | - Ingvild Straumsheim Hoem
- Department of Radiotherapy, St. Olavs Hospital, Trondheim, Norway
- Department of Physics, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| | | | - Monika Eidem
- Department of Radiotherapy, St. Olavs Hospital, Trondheim, Norway
| | | | | | | | - Jomar Frengen
- Department of Radiotherapy, St. Olavs Hospital, Trondheim, Norway
| | - Anne Beate Langeland Marthinsen
- Department of Radiotherapy, St. Olavs Hospital, Trondheim, Norway
- Department of Physics, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| |
Collapse
|
3
|
Caricato P, Trivellato S, Pellegrini R, Montanari G, Daniotti MC, Bordigoni B, Faccenda V, Panizza D, Meregalli S, Bonetto E, Voet P, Arcangeli S, De Ponti E. Updating approach for lexicographic optimization-based planning to improve cervical cancer plan quality. Discov Oncol 2023; 14:180. [PMID: 37775613 PMCID: PMC10541351 DOI: 10.1007/s12672-023-00800-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2023] [Accepted: 09/25/2023] [Indexed: 10/01/2023] Open
Abstract
BACKGROUND To investigate the capability of a not-yet commercially available fully automated lexicographic optimization (LO) planning algorithm, called mCycle (Elekta AB, Stockholm, Sweden), to further improve the plan quality of an already-validated Wish List (WL) pushing on the organs-at-risk (OAR) sparing without compromising target coverage and plan delivery accuracy. MATERIAL AND METHODS Twenty-four mono-institutional consecutive cervical cancer Volumetric-Modulated Arc Therapy (VMAT) plans delivered between November 2019 and April 2022 (50 Gy/25 fractions) have been retrospectively selected. In mCycle the LO planning algorithm was combined with the a-priori multi-criterial optimization (MCO). Two versions of WL have been defined to reproduce manual plans (WL01), and to improve the OAR sparing without affecting minimum target coverage and plan delivery accuracy (WL02). Robust WLs have been tuned using a subset of 4 randomly selected patients. The remaining plans have been automatically re-planned by using the designed WLs. Manual plans (MP) and mCycle plans (mCP01 and mCP02) were compared in terms of dose distributions, complexity, delivery accuracy, and clinical acceptability. Two senior physicians independently performed a blind clinical evaluation, ranking the three competing plans. Furthermore, a previous defined global quality index has been used to gather into a single score the plan quality evaluation. RESULTS The WL tweaking requests 5 and 3 working days for the WL01 and the WL02, respectively. The re-planning took in both cases 3 working days. mCP01 best performed in terms of target coverage (PTV V95% (%): MP 98.0 [95.6-99.3], mCP01 99.2 [89.7-99.9], mCP02 96.9 [89.4-99.5]), while mCP02 showed a large OAR sparing improvement, especially in the rectum parameters (e.g., Rectum D50% (Gy): MP 41.7 [30.2-47.0], mCP01 40.3 [31.4-45.8], mCP02 32.6 [26.9-42.6]). An increase in plan complexity has been registered in mCPs without affecting plan delivery accuracy. In the blind comparisons, all automated plans were considered clinically acceptable, and mCPs were preferred over MP in 90% of cases. Globally, automated plans registered a plan quality score at least comparable to MP. CONCLUSIONS This study showed the flexibility of the Lexicographic approach in creating more demanding Wish Lists able to potentially minimize toxicities in RT plans.
Collapse
Affiliation(s)
- Paolo Caricato
- Medical Physics Department, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy.
- Department of Physics, University of Milan, Milan, Italy.
| | - Sara Trivellato
- Medical Physics Department, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
| | | | - Gianluca Montanari
- Medical Physics Department, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
| | - Martina Camilla Daniotti
- Medical Physics Department, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
- Department of Physics, University of Milan, Milan, Italy
| | - Bianca Bordigoni
- Medical Physics Department, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
- Department of Physics, University of Milano Bicocca, Milan, Italy
| | - Valeria Faccenda
- Medical Physics Department, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
- Department of Physics, University of Milan, Milan, Italy
| | - Denis Panizza
- Medical Physics Department, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
| | - Sofia Meregalli
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
- Department of Radiation Oncology, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
| | - Elisa Bonetto
- Department of Radiation Oncology, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
| | - Peter Voet
- Research Clinical Liaison, Elekta AB, Stockholm, Sweden
| | - Stefano Arcangeli
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
- Department of Radiation Oncology, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
| | - Elena De Ponti
- Medical Physics Department, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
| |
Collapse
|
4
|
Flower E, Sykes J, Sullivan E, Busuttil G, Thiruthaneeswaran N, Cosgriff E, Chard J, Salkeld A, Thwaites D. Improving plan quality in cervical brachytherapy using a simple knowledge-based prediction tool for OAR dose (D2cm 3). Brachytherapy 2023; 22:623-629. [PMID: 37296007 DOI: 10.1016/j.brachy.2023.05.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 04/28/2023] [Accepted: 05/06/2023] [Indexed: 06/12/2023]
Abstract
PURPOSE Toxicity from cervical brachytherapy has been demonstrated to correlate with the D2cm3 of the bladder, rectum, and bowel. This suggests a simplified version of knowledge-based planning investigating the relationship of the overlap distance for 2cm3 and the D2cm3 from planning may be possible. This work demonstrates the feasibility of simple knowledge-based planning to predict the D2cm3, detect suboptimal plans, and improve plan quality. METHODS AND MATERIALS The overlap volume histogram (OVH) method was used to determine the distance for 2cm3 of overlap between the OAR and CTV_HR. Linear plots modeled the OAR D2cm3 and 2cm3 overlap distance. Two datasets of 20 patients (plans from 43 insertions in each dataset) were used to create two independent models, and the performance of each model was compared using cross-validation. Doses were scaled to ensure consistent CTV_HR D90 values. The predicted D2cm3 is entered as the maximum constraint in the inverse planning algorithm. RESULTS Mean bladder D2cm3 decreased by 2.9% for the models from each dataset, mean rectal D2cm3 decreased 14.9% for the model from dataset 1 and 6.0% for the model from dataset 2, mean sigmoid D2cm3 decreased 10.7% for the model from dataset 1 and 6.1% for the model from dataset 2, mean bowel D2cm3 decreased 4.1% for the model from dataset 1 but no statistically significant difference was observed for the model from dataset 2. CONCLUSIONS A simplified knowledge-based planning method was used to predict D2cm3 and was able to automate optimization of brachytherapy plans for locally advanced cervical cancer.
Collapse
Affiliation(s)
- Emily Flower
- Sydney West Radiation Oncology Network, Westmead, New South Wales, Australia; School of Physics, University of Sydney, Sydney, Australia.
| | - Jonathan Sykes
- Sydney West Radiation Oncology Network, Westmead, New South Wales, Australia; School of Physics, University of Sydney, Sydney, Australia
| | - Emma Sullivan
- Sydney West Radiation Oncology Network, Westmead, New South Wales, Australia
| | - Gemma Busuttil
- Sydney West Radiation Oncology Network, Westmead, New South Wales, Australia
| | | | - Eireann Cosgriff
- Sydney West Radiation Oncology Network, Westmead, New South Wales, Australia
| | - Jennifer Chard
- Sydney West Radiation Oncology Network, Westmead, New South Wales, Australia
| | - Alison Salkeld
- Sydney West Radiation Oncology Network, Westmead, New South Wales, Australia; School of Medicine, University of Sydney, Sydney, Australia
| | - David Thwaites
- School of Physics, University of Sydney, Sydney, Australia
| |
Collapse
|
5
|
Li Z, Yang Z, Lu J, Zhu Q, Wang Y, Zhao M, Li Z, Fu J. Deep learning-based dose map prediction for high-dose-rate brachytherapy. Phys Med Biol 2023; 68:175015. [PMID: 37589292 DOI: 10.1088/1361-6560/acecd2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Accepted: 08/02/2023] [Indexed: 08/18/2023]
Abstract
Background. Creating a clinically acceptable plan in the time-sensitive clinic workflow of brachytherapy is challenging. Deep learning-based dose prediction techniques have been reported as promising solutions with high efficiency and accuracy. However, current dose prediction studies mainly target EBRT which are inappropriate for brachytherapy, the model designed specifically for brachytherapy has not yet well-established.Purpose. To predict dose distribution in brachytherapy using a novel Squeeze and Excitation Attention Net (SE_AN) model.Method. We hypothesized the tracks of192Ir inside applicators are essential for brachytherapy dose prediction. To emphasize the applicator contribution, a novel SE module was integrated into a Cascaded UNet to recalibrate informative features and suppress less useful ones. The Cascaded UNet consists of two stacked UNets, with the first designed to predict coarse dose distribution and the second added for fine-tuning 250 cases including all typical clinical applicators were studied, including vaginal, tandem and ovoid, multi-channel, and free needle applicators. The developed SE_AN was subsequently compared to the classic UNet and classic Cascaded UNet (without SE module) models. The model performance was evaluated by comparing the predicted dose against the clinically approved plans using mean absolute error (MAE) of DVH metrics, includingD2ccandD90%.Results. The MAEs of DVH metrics demonstrated that SE_AN accurately predicted the dose with 0.37 ± 0.25 difference for HRCTVD90%, 0.23 ± 0.14 difference for bladderD2cc, and 0.28 ± 0.20 difference for rectumD2cc. In comparison studies, UNet achieved 0.34 ± 0.24 for HRCTV, 0.25 ± 0.20 for bladder, 0.25 ± 0.21 for rectum, and Cascaded UNet achieved 0.42 ± 0.31 for HRCTV, 0.24 ± 0.19 for bladder, 0.23 ± 0.19 for rectum.Conclusion. We successfully developed a method specifically for 3D brachytherapy dose prediction. Our model demonstrated comparable performance to clinical plans generated by experienced dosimetrists. The developed technique is expected to improve the standardization and quality control of brachytherapy treatment planning.
Collapse
Affiliation(s)
- Zhen Li
- Shanghai Sixth People's Hospital, Shanghai, People's Republic of China
| | - Zhenyu Yang
- Duke University, Durham, NC, United States of America
| | - Jiayu Lu
- Boston University, Boston, MA, United States of America
| | - Qingyuan Zhu
- Shanghai Sixth People's Hospital, Shanghai, People's Republic of China
| | - Yanxiao Wang
- Shanghai Sixth People's Hospital, Shanghai, People's Republic of China
| | - Mengli Zhao
- Shanghai Sixth People's Hospital, Shanghai, People's Republic of China
| | - Zhaobin Li
- Shanghai Sixth People's Hospital, Shanghai, People's Republic of China
| | - Jie Fu
- Shanghai Sixth People's Hospital, Shanghai, People's Republic of China
| |
Collapse
|
6
|
Pirlepesov F, Wilson L, Moskvin VP, Breuer A, Parkins F, Lucas JT, Merchant TE, Faught AM. Three-dimensional dose and LET D prediction in proton therapy using artificial neural networks. Med Phys 2022; 49:7417-7427. [PMID: 36227617 PMCID: PMC9872814 DOI: 10.1002/mp.16043] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 08/30/2022] [Accepted: 09/21/2022] [Indexed: 01/26/2023] Open
Abstract
PURPOSE Challenges in proton therapy include identifying patients most likely to benefit; ensuring consistent, high-quality plans as its adoption becomes more widespread; and recognizing biological uncertainties that may be related to increased relative biologic effectiveness driven by linear energy transfer (LET). Knowledge-based planning (KBP) is a domain that may help to address all three. METHODS Artificial neural networks were trained using 117 unique treatment plans and associated dose and dose-weighted LET (LETD ) distributions. The data set was split into training (n = 82), validation (n = 17), and test (n = 18) sets. Model performance was evaluated on the test set using dose- and LETD -volume metrics in the clinical target volume (CTV) and nearby organs at risk and Dice similarity coefficients (DSC) comparing predicted and planned isodose lines at 50%, 75%, and 95% of the prescription dose. RESULTS Dose-volume metrics significantly differed (α = 0.05) between predicted and planned dose distributions in only one dose-volume metric, D2% to the CTV. The maximum observed root mean square (RMS) difference between corresponding metrics was 4.3 GyRBE (8% of prescription) for D1cc to optic chiasm. DSC were 0.90, 0.93, and 0.88 for the 50%, 75%, and 95% isodose lines, respectively. LETD -volume metrics significantly differed in all but one metric, L0.1cc of the brainstem. The maximum observed difference in RMS differences for LETD metrics was 1.0 keV/μm for L0.1cc to brainstem. CONCLUSIONS We have devised the first three-dimensional dose and LETD -prediction model for cranial proton radiation therapy has been developed. Dose accuracy compared favorably with that of previously published models in other treatment sites. The agreement in LETD supports future investigations with biological doses in mind to enable the full potential of KBP in proton therapy.
Collapse
Affiliation(s)
- Fakhriddin Pirlepesov
- Department of Radiation Oncology, St. Jude
Children’s Research Hospital, 262 Danny Thomas Place, Memphis, TN,
38105-3678
| | - Lydia Wilson
- Department of Radiation Oncology, St. Jude
Children’s Research Hospital, 262 Danny Thomas Place, Memphis, TN,
38105-3678
| | - Vadim P. Moskvin
- Department of Radiation Oncology, St. Jude
Children’s Research Hospital, 262 Danny Thomas Place, Memphis, TN,
38105-3678
| | - Alex Breuer
- Department of Pathology, St. Jude Children’s
Research Hospital, 262 Danny Thomas Place, Memphis, TN, 38105-3678
| | - Franz Parkins
- Department of Information Services, St. Jude
Children’s Research Hospital, 262 Danny Thomas Place, Memphis, TN,
38105-3678
| | - John T. Lucas
- Department of Radiation Oncology, St. Jude
Children’s Research Hospital, 262 Danny Thomas Place, Memphis, TN,
38105-3678
| | - Thomas E. Merchant
- Department of Radiation Oncology, St. Jude
Children’s Research Hospital, 262 Danny Thomas Place, Memphis, TN,
38105-3678
| | - Austin M. Faught
- Department of Radiation Oncology, St. Jude
Children’s Research Hospital, 262 Danny Thomas Place, Memphis, TN,
38105-3678
| |
Collapse
|
7
|
Trivellato S, Caricato P, Pellegrini R, Montanari G, Daniotti MC, Bordigoni B, Faccenda V, Panizza D, Meregalli S, Bonetto E, Arcangeli S, De Ponti E. Comprehensive dosimetric and clinical evaluation of lexicographic optimization-based planning for cervical cancer. Front Oncol 2022; 12:1041839. [PMID: 36465394 PMCID: PMC9709287 DOI: 10.3389/fonc.2022.1041839] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Accepted: 10/25/2022] [Indexed: 11/01/2023] Open
Abstract
AIM In this study, a not yet commercially available fully-automated lexicographic optimization (LO) planning algorithm, called mCycle (Elekta AB, Stockholm, Sweden), was validated for cervical cancer. MATERIAL AND METHODS Twenty-four mono-institutional consecutive treatment plans (50 Gy/25 fx) delivered between November 2019 and April 2022 were retrospectively selected. The automatic re-planning was performed by mCycle, implemented in the Monaco TPS research version (v5.59.13), in which the LO and Multicriterial Optimization (MCO) are coupled with Monte Carlo calculation. mCycle optimization follows an a priori assigned priority list, the so-called Wish List (WL), representing a dialogue between the radiation oncologist and the planner, setting hard constraints and following objectives. The WL was tuned on a patient subset according to the institution's clinical protocol to obtain an optimal plan in a single optimization. This robust WL was then used to automatically re-plan the remaining patients. Manual plans (MP) and mCycle plans (mCP) were compared in terms of dose distributions, complexity (modulation complexity score, MCS), and delivery accuracy (perpendicular diode matrices, gamma analysis-passing ratio, PR). Their clinical acceptability was assessed through the blind choice of two radiation oncologists. Finally, a global quality score index (SI) was defined to gather into a single number the plan evaluation process. RESULTS The WL tuning requested four patients. The 20 automated re-planning tasks took three working days. The median optimization and calculation time can be estimated at 4 h and just over 1 h per MP and mCP, respectively. The dose comparison showed a comparable organ-at-risk spare. The planning target volume coverage increased (V95%: MP 98.0% [95.6-99.3]; mCP 99.2%[89.7-99.9], p >0.05). A significant increase has been registered in MCS (MP 0.29 [0.24-0.34]; mCP 0.26 [0.23-0.30], p <0.05) without affecting delivery accuracy (PR (3%/3mm): MP 97.0% [92.7-99.2]; mCP 97.1% [95.0-98.6], p >0.05). In the blind choice, all mCP results were clinically acceptable and chosen over MP in more than 75% of cases. The median SI score was 0.69 [0.41-0.84] and 0.73 [0.51-0.82] for MP and mCP, respectively (p >0.05). CONCLUSIONS mCycle plans were comparable to clinical manual plans, more complex but accurately deliverable and registering a similar SI. Automated plans outperformed manual plans in blinded clinical choice.
Collapse
Affiliation(s)
- Sara Trivellato
- Medical Physics Department, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
| | - Paolo Caricato
- Medical Physics Department, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
- Department of Physics, University of Milan, Milan, Italy
| | | | - Gianluca Montanari
- Medical Physics Department, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
| | - Martina Camilla Daniotti
- Medical Physics Department, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
- Department of Physics, University of Milan, Milan, Italy
| | - Bianca Bordigoni
- Medical Physics Department, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
- Department of Physics, University of Milan Bicocca, Milan, Italy
| | - Valeria Faccenda
- Medical Physics Department, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
- Department of Physics, University of Milan, Milan, Italy
| | - Denis Panizza
- Medical Physics Department, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
| | - Sofia Meregalli
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
- Department of Radiation Oncology, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
| | - Elisa Bonetto
- Department of Radiation Oncology, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
| | - Stefano Arcangeli
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
- Department of Radiation Oncology, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
| | - Elena De Ponti
- Medical Physics Department, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
| |
Collapse
|
8
|
Li X, Ge Y, Wu Q, Wang C, Sheng Y, Wang W, Stephens H, Yin FF, Wu QJ. Input feature design and its impact on the performance of deep learning models for predicting fluence maps in intensity-modulated radiation therapy. Phys Med Biol 2022; 67:215009. [PMID: 36206747 DOI: 10.1088/1361-6560/ac9882] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Accepted: 10/07/2022] [Indexed: 06/16/2023]
Abstract
Objective. Deep learning (DL) models for fluence map prediction (FMP) have great potential to reduce treatment planning time in intensity-modulated radiation therapy (IMRT) by avoiding the lengthy inverse optimization process. This study aims to improve the rigor of input feature design in a DL-FMP model by examining how different designs of input features influence model prediction performance.Approach. This study included 231 head-and-neck intensity-modulated radiation therapy patients. Three input feature designs were investigated. The first design (D1) assumed that information of all critical structures from all beam angles should be combined to predict fluence maps. The second design (D2) assumed that local anatomical information was sufficient for predicting radiation intensity of a beamlet at a respective beam angle. The third design (D3) assumed the need for both local anatomical information and inter-beam modulation to predict radiation intensity values of the beamlets that intersect at a voxel. For each input design, we tailored the DL model accordingly. All models were trained using the same set of ground truth plans (GT plans). The plans generated by DL models (DL plans) were analyzed using key dose-volume metrics. One-way ANOVA with multiple comparisons correction (Bonferroni method) was performed (significance level = 0.05).Main results. For PTV-related metrics, all DL plans had significantly higher maximum dose (p < 0.001), conformity index (p < 0.001), and heterogeneity index (p < 0.001) compared to GT plans, with D2 being the worst performer. Meanwhile, except for cord+5 mm (p < 0.001), DL plans of all designs resulted in OAR dose metrics that are comparable to those of GT plans.Significance. Local anatomical information contains most of the information that DL models need to predict fluence maps for clinically acceptable OAR sparing. Input features from beam angles are needed to achieve the best PTV coverage. These results provide valuable insights for further improvement of DL-FMP models and DL models in general.
Collapse
Affiliation(s)
- Xinyi Li
- Duke University Medical Center, United States of America
| | - Yaorong Ge
- University of North Carolina at Charlotte, United States of America
| | - Qiuwen Wu
- Duke University Medical Center, United States of America
| | - Chunhao Wang
- Duke University Medical Center, United States of America
| | - Yang Sheng
- Duke University Medical Center, United States of America
| | - Wentao Wang
- Duke University Medical Center, United States of America
| | | | - Fang-Fang Yin
- Duke University Medical Center, United States of America
| | - Q Jackie Wu
- Duke University Medical Center, United States of America
| |
Collapse
|
9
|
Li Z, Chen K, Yang Z, Zhu Q, Yang X, Li Z, Fu J. A personalized DVH prediction model for HDR brachytherapy in cervical cancer treatment. Front Oncol 2022; 12:967436. [PMID: 36110960 PMCID: PMC9468814 DOI: 10.3389/fonc.2022.967436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2022] [Accepted: 08/02/2022] [Indexed: 11/21/2022] Open
Abstract
Purpose Although the knowledge-based dose-volume histogram (DVH) prediction has been largely researched and applied in External Beam Radiation Therapy, it is still less investigated in the domain of brachytherapy. The purpose of this study is to develop a reliable DVH prediction method for high-dose-rate brachytherapy plans. Method A DVH prediction workflow combining kernel density estimation (KDE), k-nearest neighbor (kNN), and principal component analysis (PCA) was proposed. PCA and kNN were first employed together to select similar patients based on principal component directions. 79 cervical cancer patients with different applicators inserted was included in this study. The KDE model was built based on the relationship between distance-to-target (DTH) and the dose in selected cases, which can be subsequently used to estimate the dose probability distribution in the validation set. Model performance of bladder and rectum was quantified by |ΔD2cc|, |ΔD1cc|, |ΔD0.1cc|, |ΔDmax|, and |ΔDmean| in the form of mean and standard deviation. The model performance between KDE only and the combination of kNN, PCA, and KDE was compared. Result 20, 30 patients were selected for rectum and bladder based on KNN and PCA, respectively. The absolute residual between the actual plans and the predicted plans were 0.38 ± 0.29, 0.4 ± 0.32, 0.43 ± 0.36, 0.97 ± 0.66, and 0.13 ± 0.99 for |ΔD2cc|, |ΔD1cc|, |ΔD0.1cc|, |ΔDmax|, and |ΔDmean| in the bladder, respectively. For rectum, the corresponding results were 0.34 ± 0.27, 0.38 ± 0.33, 0.63 ± 0.57, 1.41 ± 0.99 and 0.23 ± 0.17, respectively. The combination of kNN, PCA, and KDE showed a significantly better prediction performance than KDE only, with an improvement of 30.3% for the bladder and 33.3% for the rectum. Conclusion In this study, a knowledge-based machine learning model was proposed and verified to accurately predict the DVH for new patients. This model is proved to be effective in our testing group in the workflow of HDR brachytherapy.
Collapse
Affiliation(s)
- Zhen Li
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| | - Kehui Chen
- Shuguang Hospital Affiliated to Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | | | - Qingyuan Zhu
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| | - Xiaojing Yang
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| | - Zhaobin Li
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| | - Jie Fu
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
- *Correspondence: Jie Fu,
| |
Collapse
|
10
|
Sheng Y, Zhang J, Ge Y, Li X, Wang W, Stephens H, Yin FF, Wu Q, Wu QJ. Artificial intelligence applications in intensity modulated radiation treatment planning: an overview. Quant Imaging Med Surg 2021; 11:4859-4880. [PMID: 34888195 PMCID: PMC8611458 DOI: 10.21037/qims-21-208] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Accepted: 07/02/2021] [Indexed: 12/15/2022]
Abstract
Artificial intelligence (AI) refers to methods that improve and automate challenging human tasks by systematically capturing and applying relevant knowledge in these tasks. Over the past decades, a number of approaches have been developed to address different types and needs of system intelligence ranging from search strategies to knowledge representation and inference to robotic planning. In the context of radiation treatment planning, multiple AI approaches may be adopted to improve the planning quality and efficiency. For example, knowledge representation and inference methods may improve dose prescription by integrating and reasoning about the domain knowledge described in many clinical guidelines and clinical trials reports. In this review, we will focus on the most studied AI approach in intensity modulated radiation therapy (IMRT)/volumetric modulated arc therapy (VMAT)-machine learning (ML) and describe our recent efforts in applying ML to improve the quality, consistency, and efficiency of IMRT/VMAT planning. With the available high-quality data, we can build models to accurately predict critical variables for each step of the planning process and thus automate and improve its outcomes. Specific to the IMRT/VMAT planning process, we can build models for each of the four critical components in the process: dose-volume histogram (DVH), Dose, Fluence, and Human Planner. These models can be divided into two general groups. The first group focuses on encoding prior experience and knowledge through ML and more recently deep learning (DL) from prior clinical plans and using these models to predict the optimal DVH (DVH prediction model), or 3D dose distribution (dose prediction model), or fluence map (fluence map model). The goal of these models is to reduce or remove the trial-and-error process and guarantee consistently high-quality plans. The second group of models focuses on mimicking human planners' decision-making process (planning strategy model) during the iterative adjustments/guidance of the optimization engine. Each critical step of the IMRT/VMAT treatment planning process can be improved and automated by AI methods. As more training data becomes available and more sophisticated models are developed, we can expect that the AI methods in treatment planning will continue to improve accuracy, efficiency, and robustness.
Collapse
Affiliation(s)
- Yang Sheng
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA
| | - Jiahan Zhang
- Department of Radiation Oncology, Emory University Hospital, Atlanta, GA, USA
| | - Yaorong Ge
- Department of Software and Information Systems, University of North Carolina at Charlotte, Charlotte, NC, USA
| | - Xinyi Li
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA
| | - Wentao Wang
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA
| | - Hunter Stephens
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA
| | - Fang-Fang Yin
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA
| | - Qiuwen Wu
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA
| | - Q. Jackie Wu
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA
| |
Collapse
|
11
|
Hardcastle N, Cook O, Ray X, Moore A, Moore KL, Pryor D, Rossi A, Foroudi F, Kron T, Siva S. Personalising treatment plan quality review with knowledge-based planning in the TROG 15.03 trial for stereotactic ablative body radiotherapy in primary kidney cancer. Radiat Oncol 2021; 16:142. [PMID: 34344402 PMCID: PMC8330099 DOI: 10.1186/s13014-021-01820-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Accepted: 05/12/2021] [Indexed: 11/10/2022] Open
Abstract
INTRODUCTION Quality assurance (QA) of treatment plans in clinical trials improves protocol compliance and patient outcomes. Retrospective use of knowledge-based-planning (KBP) in clinical trials has demonstrated improved treatment plan quality and consistency. We report the results of prospective use of KBP for real-time QA of treatment plan quality in the TROG 15.03 FASTRACK II trial, which evaluates efficacy of stereotactic ablative body radiotherapy (SABR) for kidney cancer. METHODS A KBP model was generated based on single institution data. For each patient in the KBP phase (open to the last 31 patients in the trial), the treating centre submitted treatment plans 7 days prior to treatment. A treatment plan was created by using the KBP model, which was compared with the submitted plan for each organ-at-risk (OAR) dose constraint. A report comparing each plan for each OAR constraint was provided to the submitting centre within 24 h of receiving the plan. The centre could then modify the plan based on the KBP report, or continue with the existing plan. RESULTS Real-time feedback using KBP was provided in 24/31 cases. Consistent plan quality was in general achieved between KBP and the submitted plan. KBP review resulted in replan and improvement of OAR dosimetry in two patients. All centres indicated that the feedback was a useful QA check of their treatment plan. CONCLUSION KBP for real-time treatment plan review was feasible for 24/31 cases, and demonstrated ability to improve treatment plan quality in two cases. Challenges include integration of KBP feedback into clinical timelines, interpretation of KBP results with respect to clinical trade-offs, and determination of appropriate plan quality improvement criteria.
Collapse
Affiliation(s)
- Nicholas Hardcastle
- Physical Sciences, Peter MacCallum Cancer Centre, 305 Grattan St, Melbourne, VIC, 3000, Australia. .,Centre for Medical Radiation Physics, University of Wollongong, Wollongong, Australia. .,Department of Oncology, Sir Peter MacCallum, University of Melbourne, Parkville, Australia.
| | - Olivia Cook
- Trans Tasman Radiation Oncology Group, Newcastle, Australia
| | - Xenia Ray
- Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, USA
| | - Alisha Moore
- Trans Tasman Radiation Oncology Group, Newcastle, Australia
| | - Kevin L Moore
- Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, USA
| | - David Pryor
- Department of Radiation Oncology, Princess Alexandra Hospital, Brisbane, Australia
| | - Alana Rossi
- Trans Tasman Radiation Oncology Group, Newcastle, Australia
| | - Farshad Foroudi
- Olivia Newton, John Cancer Centre at Austin Health, Heidelberg, Australia
| | - Tomas Kron
- Physical Sciences, Peter MacCallum Cancer Centre, 305 Grattan St, Melbourne, VIC, 3000, Australia.,Centre for Medical Radiation Physics, University of Wollongong, Wollongong, Australia.,Department of Oncology, Sir Peter MacCallum, University of Melbourne, Parkville, Australia
| | - Shankar Siva
- Department of Oncology, Sir Peter MacCallum, University of Melbourne, Parkville, Australia.,Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Australia
| |
Collapse
|
12
|
Zhou P, Li X, Zhou H, Fu X, Liu B, Zhang Y, Lin S, Pang H. Support Vector Machine Model Predicts Dose for Organs at Risk in High-Dose Rate Brachytherapy of Cervical Cancer. Front Oncol 2021; 11:619384. [PMID: 34336640 PMCID: PMC8319952 DOI: 10.3389/fonc.2021.619384] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Accepted: 06/25/2021] [Indexed: 11/13/2022] Open
Abstract
Introduction This study aimed to establish a support vector machine (SVM) model to predict the dose for organs at risk (OARs) in intracavitary brachytherapy planning for cervical cancer with tandem and ovoid treatments. Methods Fifty patients with loco-regionally advanced cervical cancer treated with 200 CT-based tandem and ovoid brachytherapy plans were included. The brachytherapy plans were randomly divided into the training (N = 160) and verification groups (N = 40). The bladder, rectum, sigmoid colon, and small intestine were divided into sub-OARs. The SVM model was established using MATLAB software based on the sub-OAR volume to predict the bladder, rectum, sigmoid colon, and small intestine D 2 c m 3 . Model performance was quantified by mean squared error (MSE) and δ ( δ = | D 2 c m 3 / D prescription ( actual ) - D 2 c m 3 / D prescription ( predicted ) | ) . The goodness of fit of the model was quantified by the coefficient of determination (R2). The accuracy and validity of the SVM model were verified using the validation group. Results The D 2 c m 3 value of the bladder, rectum, sigmoid colon, and small intestine correlated with the volume of the corresponding sub-OARs in the training group. The mean squared error (MSE) in the SVM model training group was <0.05; the R2 of each OAR was >0.9. There was no significant difference between the D 2 c m 3 -predicted and actual values in the validation group (all P > 0.05): bladder δ = 0.024 ± 0.022, rectum δ = 0.026 ± 0.014, sigmoid colon δ = 0.035 ± 0.023, and small intestine δ = 0.032 ± 0.025. Conclusion The SVM model established in this study can effectively predict the D 2 c m 3 for the bladder, rectum, sigmoid colon, and small intestine in cervical cancer brachytherapy.
Collapse
Affiliation(s)
- Ping Zhou
- Department of Radiology, The Affiliated Hospital of Southwest Medical University, Luzhou, China
| | - Xiaojie Li
- Department of Oncology, The Affiliated Hospital of Southwest Medical University, Luzhou, China
| | - Hao Zhou
- Department of Nursing College, Southwest Medical University, Luzhou, China
| | - Xiao Fu
- Department of Nursing College, Southwest Medical University, Luzhou, China
| | - Bo Liu
- Department of Nursing College, Southwest Medical University, Luzhou, China
| | - Yu Zhang
- Department of Nursing College, Southwest Medical University, Luzhou, China
| | - Sheng Lin
- Department of Oncology, The Affiliated Hospital of Southwest Medical University, Luzhou, China
| | - Haowen Pang
- Department of Oncology, The Affiliated Hospital of Southwest Medical University, Luzhou, China
| |
Collapse
|
13
|
Swamidas J, Pradhan S, Chopra S, Panda S, Gupta Y, Sood S, Mohanty S, Jain J, Joshi K, Ph R, Gurram L, Mahantshetty U, Prakash Agarwal J. Development and clinical validation of Knowledge-based planning for Volumetric Modulated Arc Therapy of cervical cancer including pelvic and para aortic fields. PHYSICS & IMAGING IN RADIATION ONCOLOGY 2021; 18:61-67. [PMID: 34258410 PMCID: PMC8254199 DOI: 10.1016/j.phro.2021.05.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 05/12/2021] [Accepted: 05/14/2021] [Indexed: 12/24/2022]
Abstract
A knowledge-based planning model was configured for VMAT of cervical cancer. Knowledge-based plans were comparable, and for some OARs, outperformed clinical plans. Improved organ sparing was observed, when individual patient geometry was considered.
Background and Purpose Knowledge-based planning (KBP) is based on a model to estimate dose-volume histograms, configured using a library of historical treatment plans to efficiently create high quality plans. The aim was to report configuration and validation of KBP for Volumetric Modulated Arc Therapy of cervical cancer. Materials and methods A KBP model was configured from the institutional database (n = 125), including lymph node positive (n = 60) and negative (n = 65) patients. KBP Predicted plans were compared with Clinical Plans (CP) and Re-plans (Predicted plan as a base-plan) to validate the model. Model quality was quantified using coefficient of determination R2, mean square error (MSE), standard two-tailed paired t-test and Wilcoxon signed rank test. Results Estimation capability of the model was good for the bowel bag (MSE = 0.001, R2 = 0.84), modest for the bladder (MSE = 0.008) and poor for the rectum (MSE = 0.02 R2 = 0.78). KBP resulted in comparable target coverage, superior organ sparing as compared to CP. Re-plans outperformed CP for the bladder, V30 (66 ± 11% vs 74 ± 11%, p < .001), V40 (48 ± 14% vs 52 ± 14%, p < .001), however sparing was modest for the bowel bag V30 (413 ± 191cm3 vs 445 ± 208cm3, p = .037) V40 (199 ± 105cm3 vs 218 ± 127cm3, p = .031). All plans were comparable for rectum, while KBP resulted in significant sparing for spinal cord, kidneys and femoral heads. Conclusion KBP yielded comparable and for some organs superior performance compared to CP resulting in conformal and homogeneous target coverage. Improved organ sparing was observed when individual patient geometry was considered.
Collapse
Affiliation(s)
- Jamema Swamidas
- Department of Radiation Oncology, ACTREC, Tata Memorial Centre, Mumbai, India.,Homi Bhabha National Institute, Mumbai, India.,Department of Medical Physics, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, India
| | - Sangram Pradhan
- Department of Radiotherapy, All India Institute of Medical Sciences, New Delhi, India.,Department of Medical Physics, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, India
| | - Supriya Chopra
- Department of Radiation Oncology, ACTREC, Tata Memorial Centre, Mumbai, India.,Homi Bhabha National Institute, Mumbai, India.,Department of Medical Physics, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, India
| | - Subhajit Panda
- Department of Radiation Oncology, ACTREC, Tata Memorial Centre, Mumbai, India.,Homi Bhabha National Institute, Mumbai, India.,Department of Medical Physics, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, India
| | - Yashna Gupta
- Department of Radiotherapy, All India Institute of Medical Sciences, Rishikesh, India.,Department of Medical Physics, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, India
| | - Sahil Sood
- Homi Bhabha National Institute, Mumbai, India.,Department of Radiation Oncology, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, India.,Department of Medical Physics, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, India
| | - Samarpita Mohanty
- Homi Bhabha National Institute, Mumbai, India.,Department of Radiation Oncology, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, India.,Department of Medical Physics, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, India
| | - Jeevanshu Jain
- Department of Radiation Oncology, ACTREC, Tata Memorial Centre, Mumbai, India.,Homi Bhabha National Institute, Mumbai, India.,Department of Medical Physics, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, India
| | - Kishore Joshi
- Department of Radiation Oncology, ACTREC, Tata Memorial Centre, Mumbai, India.,Homi Bhabha National Institute, Mumbai, India.,Department of Medical Physics, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, India
| | - Reena Ph
- Department of Radiation Oncology, ACTREC, Tata Memorial Centre, Mumbai, India.,Homi Bhabha National Institute, Mumbai, India.,Department of Medical Physics, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, India
| | - Lavanya Gurram
- Homi Bhabha National Institute, Mumbai, India.,Department of Radiation Oncology, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, India.,Department of Medical Physics, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, India
| | - Umesh Mahantshetty
- Homi Bhabha National Institute, Mumbai, India.,Department of Radiation Oncology, Homi Bhabha Cancer Hospital and Research Centre, Vishakapatnam, India.,Department of Medical Physics, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, India
| | - Jai Prakash Agarwal
- Homi Bhabha National Institute, Mumbai, India.,Department of Radiation Oncology, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, India.,Department of Medical Physics, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, India
| |
Collapse
|