1
|
Abou-Shady A, Ali ME, Ismail S, Abd-Elmottaleb O, Kotp YH, Osman MA, Hegab RH, Habib AA, Saudi AM, Eissa D, Yaseen R, Ibrahim GA, Yossif TM, El-Araby H, Selim EMM, Tag-Elden MA, Elwa AES, El-Harairy A. Comprehensive review of progress made in soil electrokinetic research during 1993–2020, Part I: process design modifications with brief summaries of main output. SOUTH AFRICAN JOURNAL OF CHEMICAL ENGINEERING 2023. [DOI: 10.1016/j.sajce.2023.01.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
|
2
|
Xu H, Cang L, Song Y, Yang J. Influence of electrode configuration on electrokinetic-enhanced persulfate oxidation remediation of PAH-contaminated soil. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2020; 27:44355-44367. [PMID: 32770336 DOI: 10.1007/s11356-020-10338-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Accepted: 07/30/2020] [Indexed: 06/11/2023]
Abstract
Electrokinetic (EK) remediation combined with in situ chemical oxidation (ISCO) can be applied to low permeability organic contaminated soil. However, the effects of electrode configuration on EK-oxidation remediation remain unclear. In this study, EK-ISCO remediation of real polycyclic aromatic hydrocarbon (PAH)-contaminated soil under different electrode configurations was conducted. The results showed that increasing the number of anodes and electrode pairs in one-dimensional (1D) and two-dimensional (2D) electrode configuration was conducive to migration of oxidants into the system. The change in soil pH after remediation in 2D electrode configuration was not obvious, but the increase of soil electrical conductivity (EC) was higher than that of the 1D electrode configuration. The removal rates of PAHs in 2D electrode configurations (35.9-40.9%) were relatively higher than those of the 1D electrode configurations (0.54-31.6%), and the hexagonal electrode configuration yielded the highest pollutant removal efficiency, reaching 40.9%. The energy consumption under 2D electrode configuration was smaller than that under 1D electrode configuration, and the energy consumption of per gram removed PAHs in the hexagon configuration (66.74 kWh (g PAHs)-1) was lowest in all electrode configurations. Overall, the results of this study suggest that 2D electrode configuration is better than 1D and hexagonal electrode configuration is an optimal electrode configuration.
Collapse
Affiliation(s)
- Hongting Xu
- Key Laboratory of Soil Environment and Pollution Remediation, Institute of Soil Science, Chinese Academy of Sciences, Nanjing, 210008, China
- Geological Survey of Jiangsu Province, Nanjing, 210018, China
| | - Long Cang
- Key Laboratory of Soil Environment and Pollution Remediation, Institute of Soil Science, Chinese Academy of Sciences, Nanjing, 210008, China.
- University of Chinese Academy of Sciences, Beijing, 100049, China.
| | - Yue Song
- Key Laboratory of Soil Environment and Pollution Remediation, Institute of Soil Science, Chinese Academy of Sciences, Nanjing, 210008, China
| | - Jiangli Yang
- Key Laboratory of Soil Environment and Pollution Remediation, Institute of Soil Science, Chinese Academy of Sciences, Nanjing, 210008, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| |
Collapse
|
3
|
Sánchez V, López-Bellido FJ, Cañizares P, Villaseñor J, Rodríguez L. Scaling up the electrokinetic-assisted phytoremediation of atrazine-polluted soils using reversal of electrode polarity: A mesocosm study. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2020; 255:109806. [PMID: 31759201 DOI: 10.1016/j.jenvman.2019.109806] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2019] [Revised: 10/18/2019] [Accepted: 10/28/2019] [Indexed: 06/10/2023]
Abstract
Electrokinetic-assisted phytoremediation (EKPR) has been recently proposed for the removal of pesticides from polluted soils. In this work, we report the results from an EKPR experiment that was carried out in a mesocosm mock-up of 0.386 m3 using ryegrass (Lolium perenne L.) and a low permeability soil spiked with atrazine. Plants were initially grown for 35 days; then, the soil was spiked with atrazine at a dose of 2 mg kg-1 soil. A DC electrical field of 0.6 V cm-1 was applied 24 h every day, switching polarity daily. Another identical mock-up with the same experimental conditions but without plants was used for comparison purposes. The duration of the EKPR test was 19 days during which some operational parameters were registered (electric current intensity, soil pH and temperature) and soil porewater samples were taken and analysed. Plant tissues and soil samples from the different sections in which the mock-ups were divided, were also collected and analysed at the end of the experiment. 3-D profiles of soil pH, water content and atrazine residues concentration in plants and soil were obtained and discussed. The results of this experiment were compared with others previously reported by us from a similar EKPR pot test. In spite of the difficulties to get an adequate geometric and operational similarity between setups of different scale, the main output parameters of the EKPR process (electric current, specific current charge, overall atrazine removal, specific atrazine removal efficiency, root biomass:soil weight ratio) were discussed. It was shown that, although the processes carried out are essentially the same in both scales, their extent may be quite different; it highlights the limitations of small-scale experiments to predict the results at field conditions.
Collapse
Affiliation(s)
- Virtudes Sánchez
- Department of Chemical Engineering, School of Civil Engineering, University of Castilla-La Mancha, Avenida Camilo José Cela, 2, 13071, Ciudad Real, Spain
| | - Francisco Javier López-Bellido
- Department of Plant Production and Agricultural Technology, School of Agricultural Engineering, University of Castilla-La Mancha, Ronda de Calatrava, S/n, 13003, Ciudad Real, Spain
| | - Pablo Cañizares
- Department of Chemical Engineering, Faculty of Chemical Sciences and Technologies, University of Castilla-La Mancha, Avenida Camilo José Cela, 10, 13071, Ciudad Real, Spain
| | - José Villaseñor
- Department of Chemical Engineering, Faculty of Chemical Sciences and Technologies, University of Castilla-La Mancha, Avenida Camilo José Cela, 10, 13071, Ciudad Real, Spain
| | - Luis Rodríguez
- Department of Chemical Engineering, School of Civil Engineering, University of Castilla-La Mancha, Avenida Camilo José Cela, 2, 13071, Ciudad Real, Spain.
| |
Collapse
|
4
|
Sánchez V, López-Bellido FJ, Rodrigo MA, Fernández FJ, Rodríguez L. A mesocosm study of electrokinetic-assisted phytoremediation of atrazine-polluted soils. Sep Purif Technol 2020. [DOI: 10.1016/j.seppur.2019.116044] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
5
|
Sánchez V, López-Bellido J, Rodrigo MA, Rodríguez L. Enhancing the removal of atrazine from soils by electrokinetic-assisted phytoremediation using ryegrass (Lolium perenne L.). CHEMOSPHERE 2019; 232:204-212. [PMID: 31154181 DOI: 10.1016/j.chemosphere.2019.05.216] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Revised: 05/08/2019] [Accepted: 05/24/2019] [Indexed: 06/09/2023]
Abstract
Atrazine (ATR) continues being one of the most frequently detected pesticides in natural waters and soils. In this work, an electrokinetic-assisted phytoremediation pot test (EKPR) was performed for the remediation of an atrazine-spiked soil; a low electric voltage gradient (1 V cm-1) with two different electric field operation times (6 and 24 h per day) was used in combination with ryegrass (Lolium perenne L.). EKPR increased up to 27% and 7% the overall ATR removal from soil as compared to natural attenuation and phytoremediation treatments, respectively. ATR soil concentration vs time curves were fitted to a pseudofirst-order kinetic equation, obtaining ATR half-life values of 8.2, 7.1 and 5.4 days for the treatments corresponding, respectively, to 0, 6 and 24 h day-1 of electric current application. It clearly showed that the ATR removal from soils was enhanced by the electric field. ATR plant accumulation was significantly improved with respect to phytoremediation when the electric current was continuously applied throughout the experiment (24 h day-1); most of the ATR residues were accumulated in the shoot biomass of the ryegrass plants.
Collapse
Affiliation(s)
- Virtudes Sánchez
- Department of Chemical Engineering, University of Castilla-La Mancha, Avenida Camilo José Cela, s/n, 13071 Ciudad Real (Spain)
| | - Javier López-Bellido
- School of Agricultural Engineering, University of Castilla-La Mancha, Ronda de Calatrava, s/n, 13003, Ciudad Real (Spain)
| | - Manuel A Rodrigo
- Department of Chemical Engineering, University of Castilla-La Mancha, Avenida Camilo José Cela, s/n, 13071 Ciudad Real (Spain)
| | - Luis Rodríguez
- Department of Chemical Engineering, University of Castilla-La Mancha, Avenida Camilo José Cela, s/n, 13071 Ciudad Real (Spain).
| |
Collapse
|
6
|
López-Vizcaíno R, Yustres A, Sáez C, Cañizares P, Asensio L, Navarro V, Rodrigo MA. Techno-economic analysis of the scale-up process of electrochemically-assisted soil remediation. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2019; 231:570-575. [PMID: 30388654 DOI: 10.1016/j.jenvman.2018.10.084] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Revised: 10/16/2018] [Accepted: 10/23/2018] [Indexed: 06/08/2023]
Abstract
This work presents a techno-economic study of the scaling-up of the electrochemically-assisted soil remediation (EASR) process of polluted soil. Four scales have been selected for the study: laboratory, bench, pilot and prototype, with a capacity of treating a volume of soil of 1 × 10-4, 2 × 10-3, 0.11 and 21.76 m3, respectively. This study analyses the technical information produced by studies carried out at each scale, and informs about the fixed costs (construction of the electrokinetic remediation reactor, installation of auxiliary services and purchase of analytical equipment) and variable costs (start-up, operation and dismantling of the test) derived from running a test at each of the evaluated scales. The information discussed in based on the experience gained with many evaluations carried out over the last decade at these scales. This information can provide useful guidance for developing a scaling-up of the EASR for many researchers starting on the evaluation of this important environmental remediation technology.
Collapse
Affiliation(s)
- R López-Vizcaíno
- Geoenvironmental Group, Civil Engineering School, University of Castilla-La Mancha, Avda. Camilo José Cela s/n, 13071 Ciudad Real, Spain.
| | - A Yustres
- Geoenvironmental Group, Civil Engineering School, University of Castilla-La Mancha, Avda. Camilo José Cela s/n, 13071 Ciudad Real, Spain
| | - C Sáez
- Department of Chemical Engineering, Faculty of Chemical Sciences & Technologies, University of Castilla-La Mancha, Campus Universitario s/n, 13071 Ciudad Real, Spain
| | - P Cañizares
- Department of Chemical Engineering, Faculty of Chemical Sciences & Technologies, University of Castilla-La Mancha, Campus Universitario s/n, 13071 Ciudad Real, Spain
| | - L Asensio
- Geoenvironmental Group, Civil Engineering School, University of Castilla-La Mancha, Avda. Camilo José Cela s/n, 13071 Ciudad Real, Spain
| | - V Navarro
- Geoenvironmental Group, Civil Engineering School, University of Castilla-La Mancha, Avda. Camilo José Cela s/n, 13071 Ciudad Real, Spain
| | - M A Rodrigo
- Department of Chemical Engineering, Faculty of Chemical Sciences & Technologies, University of Castilla-La Mancha, Campus Universitario s/n, 13071 Ciudad Real, Spain
| |
Collapse
|
7
|
Rodrigo S, Saez C, Cañizares P, Rodrigo MA. Reversible electrokinetic adsorption barriers for the removal of organochlorine herbicide from spiked soils. THE SCIENCE OF THE TOTAL ENVIRONMENT 2018; 640-641:629-636. [PMID: 29870938 DOI: 10.1016/j.scitotenv.2018.05.364] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Revised: 05/10/2018] [Accepted: 05/28/2018] [Indexed: 06/08/2023]
Abstract
This work aims to describe the removal of clopyralid from clay soils using electrokinetically assisted soil flushing (EKSF) coupled with a permeable reactive barrier (PRB), consisting of beds of Granulated Activated Carbon (GAC). To do this, two strategies have been evaluated on bench-scale electroremediation facilities (175 dm3): electrokinetic adsorption barrier (EKAB) and reversible electrokinetic adsorption barrier (REKAB). Likewise, to clarify the contribution of the different mechanisms to remediation process results are compared to those obtained in a reference test (without applying an electric field) and to results obtained in the EKSF of soils polluted with compounds with different polarity and vapour pressure. Results show that during EKAB and REKAB tests, clopyralid is removed from the soil by adsorption in PRB, electrokinetic transport and, very less decisively, by evaporation. The application of polarity reversion attains a higher retention of clopyralid in the activated carbon-PRB and a better regulation of pH because of the neutralization of H+ and OH- generated in the electrolyte wells. After 30 days of operation, the removal of clopyralid by EKAB is 45% while it reaches 57% in the case of REKAB.
Collapse
Affiliation(s)
- S Rodrigo
- Department of Chemical Engineering, Instituto de Tecnologías Química y Medioambiental, University of Castilla-La Mancha, Campus Universitario s/n, 13071 Ciudad Real, Spain
| | - C Saez
- Department of Chemical Engineering, Instituto de Tecnologías Química y Medioambiental, University of Castilla-La Mancha, Campus Universitario s/n, 13071 Ciudad Real, Spain.
| | - P Cañizares
- Department of Chemical Engineering, Instituto de Tecnologías Química y Medioambiental, University of Castilla-La Mancha, Campus Universitario s/n, 13071 Ciudad Real, Spain
| | - M A Rodrigo
- Department of Chemical Engineering, Instituto de Tecnologías Química y Medioambiental, University of Castilla-La Mancha, Campus Universitario s/n, 13071 Ciudad Real, Spain
| |
Collapse
|
8
|
|
9
|
Yustres Á, López-Vizcaíno R, Sáez C, Cañizares P, Rodrigo M, Navarro V. Water transport in electrokinetic remediation of unsaturated kaolinite. Experimental and numerical study. Sep Purif Technol 2018. [DOI: 10.1016/j.seppur.2017.10.009] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
10
|
Muñoz M, Llanos J, Raschitor A, Cañizares P, Rodrigo MA. Electrocoagulation as the Key for an Efficient Concentration and Removal of Oxyfluorfen from Liquid Wastes. Ind Eng Chem Res 2017. [DOI: 10.1021/acs.iecr.7b00347] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Affiliation(s)
- Martín Muñoz
- Chemical Engineering Department, University of Castilla-La Mancha, Enrique Costa Novella Building,
Campus Universitario s/n, Ciudad Real 13005, Spain
| | - Javier Llanos
- Chemical Engineering Department, University of Castilla-La Mancha, Enrique Costa Novella Building,
Campus Universitario s/n, Ciudad Real 13005, Spain
| | - Alexandra Raschitor
- Chemical Engineering Department, University of Castilla-La Mancha, Enrique Costa Novella Building,
Campus Universitario s/n, Ciudad Real 13005, Spain
| | - Pablo Cañizares
- Chemical Engineering Department, University of Castilla-La Mancha, Enrique Costa Novella Building,
Campus Universitario s/n, Ciudad Real 13005, Spain
| | - Manuel A. Rodrigo
- Chemical Engineering Department, University of Castilla-La Mancha, Enrique Costa Novella Building,
Campus Universitario s/n, Ciudad Real 13005, Spain
| |
Collapse
|
11
|
López-Vizcaíno R, Risco C, Isidro J, Rodrigo S, Saez C, Cañizares P, Navarro V, Rodrigo MA. Scale-up of the electrokinetic fence technology for the removal of pesticides. Part II: Does size matter for removal of herbicides? CHEMOSPHERE 2017; 166:549-555. [PMID: 27692679 DOI: 10.1016/j.chemosphere.2016.09.114] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Revised: 09/23/2016] [Accepted: 09/24/2016] [Indexed: 06/06/2023]
Abstract
This work reports results of the application of electrokinetic fence technology in a 32 m3 -prototype which contains soil polluted with 2,4-D and oxyfluorfen, focusing on the evaluation of the mechanisms that describe the removal of these two herbicides and comparing results to those obtained in smaller plants: a pilot-scale mockup (175 L) and a lab-scale soil column (1 L). Results show that electric heating of soil (coupled with the increase in the volatility) is the key to explain the removal of pollutants in the largest scale facility while electrokinetic transport processes are the primary mechanisms that explain the removal of herbicides in the lab-scale plant. 2-D and 3-D maps of the temperature and pollutant concentrations are used in the discussion of results trying to give light about the mechanisms and about how the size of the setup can lead to different conclusions, despite the same processes are occurring in the soil.
Collapse
Affiliation(s)
- R López-Vizcaíno
- Department of Chemical Engineering, Facultad de Ciencias y Tecnologías Químicas, University of Castilla-La Mancha, Campus Universitario s/n, 13071, Ciudad Real, Spain
| | - C Risco
- Department of Chemical Engineering, Instituto de Tecnologías Química y Medioambiental, University of Castilla-La Mancha, Campus Universitario s/n, 13071, Ciudad Real, Spain
| | - J Isidro
- Department of Chemical Engineering, Instituto de Tecnologías Química y Medioambiental, University of Castilla-La Mancha, Campus Universitario s/n, 13071, Ciudad Real, Spain
| | - S Rodrigo
- Department of Chemical Engineering, Instituto de Tecnologías Química y Medioambiental, University of Castilla-La Mancha, Campus Universitario s/n, 13071, Ciudad Real, Spain
| | - C Saez
- Department of Chemical Engineering, Facultad de Ciencias y Tecnologías Químicas, University of Castilla-La Mancha, Campus Universitario s/n, 13071, Ciudad Real, Spain
| | - P Cañizares
- Department of Chemical Engineering, Facultad de Ciencias y Tecnologías Químicas, University of Castilla-La Mancha, Campus Universitario s/n, 13071, Ciudad Real, Spain
| | - V Navarro
- Geoenvironmental Group, Civil Engineering School, University of Castilla-La Mancha, Avda. Camilo José Cela s/n, 13071, Ciudad Real, Spain
| | - M A Rodrigo
- Department of Chemical Engineering, Facultad de Ciencias y Tecnologías Químicas, University of Castilla-La Mancha, Campus Universitario s/n, 13071, Ciudad Real, Spain.
| |
Collapse
|
12
|
López-Vizcaíno R, Risco C, Isidro J, Rodrigo S, Saez C, Cañizares P, Navarro V, Rodrigo MA. Scale-up of the electrokinetic fence technology for the removal of pesticides. Part I: Some notes about the transport of inorganic species. CHEMOSPHERE 2017; 166:540-548. [PMID: 27692680 DOI: 10.1016/j.chemosphere.2016.09.113] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Revised: 09/23/2016] [Accepted: 09/24/2016] [Indexed: 06/06/2023]
Abstract
This work describes the application electrokinetic fence technology to a soil polluted with herbicides in a large prototype containing 32 m3 of soil. It compares performance in this large facility with results previously obtained in a pilot-scale mockup (175 L) and with results obtained in a lab-scale soil column (1 L), all of them operated under the same driving force: an electric field of 1.0 V cm-1. Within this wide context, this work focuses on the effect on inorganic species contained in soil and describes the main processes occurring in the prototype facility, as well as the differences observed respect to the lower scale plants. Thus, despite the same processes can be described in the three plants, important differences are observed in the evolution of the current intensity, moisture and conductivity. They can be related to the less important electroosmotic fluxes in the larger facilities and to the very different distances between electrodes, which lead to very different distribution of species and even to a very different evolution of the resulting current intensity. 2-D maps of the main species at different relevant moments of the test are discussed and important information is drawn from them. Ions depletion from soil appears as a very important problem which should be prevented if the effect of natural bioremediation and/or phytoremediation on the removal or organics aims to be accounted.
Collapse
Affiliation(s)
- R López-Vizcaíno
- Department of Chemical Engineering, Facultad de Ciencias y Tecnologías Químicas, University of Castilla-La Mancha, Campus Universitario s/n, 13071 Ciudad Real, Spain
| | - C Risco
- Department of Chemical Engineering, Instituto de Tecnologías Química y Medioambiental, University of Castilla-La Mancha, Campus Universitario s/n, 13071 Ciudad Real, Spain
| | - J Isidro
- Department of Chemical Engineering, Instituto de Tecnologías Química y Medioambiental, University of Castilla-La Mancha, Campus Universitario s/n, 13071 Ciudad Real, Spain
| | - S Rodrigo
- Department of Chemical Engineering, Instituto de Tecnologías Química y Medioambiental, University of Castilla-La Mancha, Campus Universitario s/n, 13071 Ciudad Real, Spain
| | - C Saez
- Department of Chemical Engineering, Facultad de Ciencias y Tecnologías Químicas, University of Castilla-La Mancha, Campus Universitario s/n, 13071 Ciudad Real, Spain
| | - P Cañizares
- Department of Chemical Engineering, Facultad de Ciencias y Tecnologías Químicas, University of Castilla-La Mancha, Campus Universitario s/n, 13071 Ciudad Real, Spain
| | - V Navarro
- Geoenvironmental Group, Civil Engineering School, University of Castilla-La Mancha, Avda. Camilo José Cela s/n, 13071 Ciudad Real, Spain
| | - M A Rodrigo
- Department of Chemical Engineering, Facultad de Ciencias y Tecnologías Químicas, University of Castilla-La Mancha, Campus Universitario s/n, 13071 Ciudad Real, Spain.
| |
Collapse
|