1
|
Anwar FN, Nie JW, Federico VP, Roca AM, Medakkar SS, Loya AC, Lopez GD, Sayari AJ, Singh K. Does Baseline Facet Arthropathy Influence Early Clinical and Radiographic Outcomes After Cervical Disc Replacement? Neurosurgery 2024:00006123-990000000-01203. [PMID: 38861645 DOI: 10.1227/neu.0000000000003029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Accepted: 04/18/2024] [Indexed: 06/13/2024] Open
Abstract
BACKGROUND AND OBJECTIVES Severe facet arthropathy is generally a contraindication to undergoing cervical disc replacement (CDR) due to associated instability and potentially limited improvement in neck pain caused by arthropathy. This study evaluates the influence of facet arthropathy on radiographic/early clinical outcomes after CDR. METHODS One/two-level CDR patients from a single surgeon's prospectively maintained database created 2 cohorts based on facet arthropathy: grade 0-1 or 2-3 (milder/moderate arthropathy). Patient-reported outcome measures for neck disability, neck/arm pain, depressive burden, mental/physical health/function were obtained preoperatively and through final follow-up (average follow-up: 8.5 ± 6.5 months). Preoperative/postoperative radiographs measured segmental lordosis and C2-C7/segmental range of motion (ROM) and determined facet grade for each operative level. Demographic differences, perioperative variables, baseline patient-reported outcomes, and intercohort differences/changes for postoperative patient-reported/radiographic outcomes were determined. RESULTS Of 161 patients, 100 were in the milder arthropathy group. There were no differences in baseline patient-reported outcomes. Patients with moderate arthropathy reported superior 6-week 12-Item Veterans Rand Mental/Physical Composite Scores (P ≤ .047, all). By final follow-up, moderate patients reported better 12-Item Veterans Rand Mental/Physical Composite Scores/Patient-Reported Outcome Measurement Information System-Physical Function/Patient-Health Questionnaire-9 (P ≤ .049, all). Cohorts reported similar improvements in all patient-reported outcomes by 6 weeks/final follow-up. Those with more severe facet arthropathy had significantly shorter preoperative disc heights (P < .001). Accounting for baseline disc height differences, by final follow-up, moderate patients had lower segmental ROM (P = .036). There were no significant differences in radiographic measurement changes (P ≥ .264, all). CONCLUSION Postoperatively, patients with moderate facet arthropathy reported lower depressive burden, better mental health/physical function, and lower segmental ROM. However, this did not translate to inferior short-term clinical outcomes. Further study should be conducted on the relationship between clinical/radiographic outcomes in CDR patients with facet arthropathy.
Collapse
Affiliation(s)
- Fatima N Anwar
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, Illinois, 60612, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
2
|
Wing-Yuk Chan R, Chiang YH, Yang YA, Chen YY, Tsou YS. One-Year Follow-Up Study on Assessing the Range of Segmental Motion and Clinical Outcomes Following Cervical Disc Arthroplasty for Treatment of Severe Cervical Disc Degeneration. World Neurosurg 2024; 183:e276-e281. [PMID: 38128758 DOI: 10.1016/j.wneu.2023.12.079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 12/13/2023] [Accepted: 12/14/2023] [Indexed: 12/23/2023]
Abstract
BACKGROUND Though previous studies have documented various clinical outcomes after cervical arthroplasty for degenerative cervical disc disease, none of them reported the impact of cervical arthroplasty on severe cervical disc degeneration (CDD). METHODS This retrospective cohort study included severe 40 CDD (C3-C7) patients who underwent single-level cervical arthroplasty using ProDisc-C between January 2017 and December 2019. After surgical intervention, the range of motion (ROM) was determined, whereas clinical outcomes were measured in terms of the Visual Analogue Scale (VAS) and Neck Disability Index (NDI) to evaluate neck pain and disability, respectively. RESULTS Compared to the mean preoperative ROM (6.57 ± 4.85°), the cervical dynamic ROM was increased 3 months after cervical arthroplasty, and the increment was maintained for at least 1 year. The increased ROM is attributed to the extension and not flexion components. The mean preoperative ROM of 6.57 ± 4.85° significantly increased to 11.67 ± 4.98° (P = 0.0005), 10.05 ± 5.18° (P = 0.0426) and 10.46 ± 4.73° (P = 0.0247) after 3 months, 6 months and 1 year, respectively. The extension ROM also revealed a similar trend. VAS for neck and arm decreased from 7.4 and 6.6 to 1.4 and 1.2, respectively. Consistently, the preoperative mean Neck Disability Index (NDI) score of 27.6 decreased to 14.6. We recorded a case of device subsidence, but without extrusion. CONCLUSIONS Cervical arthroplasty can improve clinical outcomes and restore ROM in severe CDD patients.
Collapse
Affiliation(s)
- Ryan Wing-Yuk Chan
- Department of Neurosurgery, Taipei Medical University Hospital, Taipei, Taiwan; Taipei Neuroscience Institute, Taipei Medical University, Taipei, Taiwan; Ph.D. Program in Medical Neuroscience, College of Medical Science and Technology, Taipei Medical University, Taipei, Taiwan
| | - Yung-Hsiao Chiang
- Department of Neurosurgery, Taipei Medical University Hospital, Taipei, Taiwan; Taipei Neuroscience Institute, Taipei Medical University, Taipei, Taiwan; Department of Surgery, School of Medicine, Taipei Medical University, Taipei, Taiwan
| | - Yi-An Yang
- Department of Nursing, Taipei Medical University Hospital, Taipei, Taiwan
| | - Yi-Yu Chen
- Department of Neurosurgery, Taipei Medical University Hospital, Taipei, Taiwan; Taipei Neuroscience Institute, Taipei Medical University, Taipei, Taiwan; Department of Nursing, Taipei Medical University Hospital, Taipei, Taiwan
| | - Yi-Syue Tsou
- Department of Neurosurgery, Taipei Medical University Hospital, Taipei, Taiwan; Taipei Neuroscience Institute, Taipei Medical University, Taipei, Taiwan; Ph.D. Program in Medical Neuroscience, College of Medical Science and Technology, Taipei Medical University, Taipei, Taiwan.
| |
Collapse
|
3
|
Kang KC, Jang TS, Jung CH. Cervical Radiculopathy: Focus on Factors for Better Surgical Outcomes and Operative Techniques. Asian Spine J 2022; 16:995-1012. [PMID: 36599372 PMCID: PMC9827215 DOI: 10.31616/asj.2022.0445] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Accepted: 12/15/2022] [Indexed: 12/31/2022] Open
Abstract
For patients with cervical radiculopathy, most studies have recommended conservative treatment as the first-line treatment; however, when conventional treatment fails, surgery is considered. A better understanding of the prognosis of cervical radiculopathy is essential to provide accurate information to the patients. If the patients complain of persistent and recurrent arm pain/numbness not respond to conservative treatment, or exhibit neurologic deficits, surgery is performed using anterior or posterior approaches. Anterior cervical discectomy and fusion (ACDF) has historically been widely used and has proven to be safe and effective. To improve surgical outcomes of ACDF surgery, many studies have been conducted on types of spacers, size/height/position of cages, anterior plating, patients' factors, surgical techniques, and so forth. Cervical disc replacement (CDR) is designed to reduce the incidence of adjacent segment disease during long-term follow-up by maintaining cervical spine motion postoperatively. Many studies on excellent indications for the CDR, proper type/size/shape/height of the implants, and surgical techniques were performed. Posterior cervical foraminotomy is a safe and effective surgical option to avoid complications associated with anterior approach and fusion surgery. Most recent literature demonstrated that all three surgical techniques for patients with cervical radiculopathy have clear advantages and disadvantages and reveal satisfactory surgical outcomes under a proper selection of patients and application of appropriate surgical methods. For this, it is important to fully understand the factors for better surgical outcomes and to adequately practice the operative techniques for patients with cervical radiculopathy.
Collapse
Affiliation(s)
- Kyung-Chung Kang
- Department of Orthopaedic Surgery, Kyung Hee University Hospital, Kyung Hee University School of Medicine, Seoul, Korea
| | - Tae Su Jang
- Department of Orthopaedic Surgery, Kyung Hee University Hospital, Kyung Hee University School of Medicine, Seoul, Korea,Corresponding author: Tae Su Jang Department of Orthopaedic Surgery, Kyung Hee University Medical Center, 23 Kyungheedae-ro, Dongdaemun-gu, Seoul 02447, Korea Tel: +82-2-958-8346, Fax: +82-2-964-3865, E-mail:
| | - Cheol Hyun Jung
- Department of Orthopaedic Surgery, Kyung Hee University Hospital, Kyung Hee University School of Medicine, Seoul, Korea
| |
Collapse
|
4
|
Zavras AG, Dandu N, Nolte MT, Butler AJ, Federico VP, Sayari AJ, Sullivan TB, Colman MW. Segmental range of motion after cervical total disc arthroplasty at long-term follow-up: a systematic review and meta-analysis. J Neurosurg Spine 2022; 37:579-587. [PMID: 35453108 DOI: 10.3171/2022.2.spine2281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Accepted: 02/21/2022] [Indexed: 11/06/2022]
Abstract
OBJECTIVE As an alternative procedure to anterior cervical discectomy and fusion, total disc arthroplasty (TDA) facilitates direct neural decompression and disc height restoration while also preserving cervical spine kinematics. To date, few studies have reported long-term functional outcomes after TDA. This paper reports the results of a systematic review and meta-analysis that investigated how segmental range of motion (ROM) at the operative level is maintained with long-term follow-up. METHODS PubMed and MEDLINE were queried for all published studies pertaining to cervical TDA. The methodology for screening adhered strictly to the PRISMA guidelines. All English-language prospective studies that reported ROM preoperatively, 1 year postoperatively, and/or at long-term follow-up of 5 years or more were included. A meta-analysis was performed using Cochran's Q and I2 to test data for statistical heterogeneity, in which case a random-effects model was used. The mean differences (MDs) and associated 95% confidence intervals (CIs) were reported. RESULTS Of the 12 studies that met the inclusion criteria, 8 reported the long-term outcomes of 944 patients with an average (range) follow-up of 99.86 (60-142) months and were included in the meta-analysis. There was no difference between preoperative segmental ROM and segmental ROM at 1-year follow-up (MD 0.91°, 95% CI -1.25° to 3.07°, p = 0.410). After the exclusion of 1 study from the comparison between preoperative and 1-year ROM owing to significant statistical heterogeneity according to the sensitivity analysis, ROM significantly improved at 1 year postoperatively (MD 1.92°, 95% CI 1.04°-2.79°, p < 0.001). However, at longer-term follow-up, the authors again found no difference with preoperative segmental ROM, and no study was excluded on the basis of the results of further sensitivity analysis (MD -0.22°, 95% CI -1.69° to -1.23°, p = 0.760). In contrast, there was a significant decrease in ROM from 1 year postoperatively to final long-term follow-up (MD -0.77°, 95% CI -1.29° to -0.24°, p = 0.004). CONCLUSIONS Segmental ROM was found to initially improve beyond preoperative values for as long as 1 year postoperatively, but then ROM deteriorated back to values consistent with preoperative motion at long-term follow-up. Although additional studies with further longitudinal follow-up are needed, these findings further support the notion that cervical TDA may successfully maintain physiological spinal kinematics over the long term.
Collapse
|
5
|
Liu Z, Rong X, Liu H, Ding C, Hong Y, Wang B. Effect of Facet Tropism on Postoperative Cervical Range of Motion After Single-Level Cervical Disc Arthroplasty. Global Spine J 2022; 12:1696-1707. [PMID: 33511887 PMCID: PMC9609535 DOI: 10.1177/2192568220986144] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
STUDY DESIGN Retrospective analysis. OBJECTIVES Cervical disc arthroplasty (CDA) was designed to replace the degenerated disc with the prosthesis to preserve cervical motion. The commonly used artificial discs are designed symmetric, whereas the facet joints were reported to be asymmetric in many people. This study aimed to evaluate the effect of facet tropism on the cervical range of motion (ROM) after single-level CDA using Prestige LP. METHODS A total of 90 patients who underwent single-level CDA using Prestige LP from 2012 to 2017 were retrospectively reviewed. Radiographs were taken at each time point to measure the C2-C7 ROM and the ROM at the surgical segment. The pre-operation CT scans were utilized to reconstruct and calculate the angular direction of facet joints with respect to transverse, coronal, and sagittal reference planes. Facet tropism above 7° was defined as facet joint asymmetry. RESULTS No significant difference was found in flexion-extension C2-C7 ROM or ROM at the surgical segment between patients with symmetric and asymmetric fact joints regarding the sagittal plane. Patients with coronal asymmetric facet joints had lower flexion-extension ROM at the surgical level. Patients with transverse asymmetric facet joints had both lower flexion-extension C2-C7 ROM and ROM at the surgical level. After CDA surgery, patients obtained good clinical outcomes including increased Japanese Orthopedic Association (JOA) and decreased Neck Disability Index (NDI) as well as Visual Analogue Scale (VAS). CONCLUSION The coronal and transverse tropism seemed to be correlated with decreased flexion-extension ROM after CDA using Prestige LP.
Collapse
Affiliation(s)
- Ziyang Liu
- Department of Orthopedics, West China
Hospital, Sichuan University, Chengdu, Sichuan Province, China,Department of Orthopedics, Tianjin
Hospital, Tianjin Province, China
| | - Xin Rong
- Department of Orthopedics, West China
Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Hao Liu
- Department of Orthopedics, West China
Hospital, Sichuan University, Chengdu, Sichuan Province, China,Hao Liu, Department of Orthopedic Surgery,
West China Hospital, No. 37, Guo Xue Xiang, Chengdu 610041, Sichuan Province,
China.
| | - Chen Ding
- Department of Orthopedics, West China
Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Ying Hong
- Department of Operating Room, West China
Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Beiyu Wang
- Department of Orthopedics, West China
Hospital, Sichuan University, Chengdu, Sichuan Province, China
| |
Collapse
|
6
|
Colman MW, Zavras AG, Federico VP, Nolte MT, Butler AJ, Singh K, Phillips FM. Longitudinal assessment of segmental motion of the cervical spine following total disc arthroplasty: a comparative analysis of devices. J Neurosurg Spine 2022; 37:556-562. [PMID: 35426820 DOI: 10.3171/2022.2.spine22143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Accepted: 02/28/2022] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Total disc arthroplasty (TDA) has been shown to be an effective and safe treatment for cervical degenerative disc disease at short- and midterm follow-up. However, there remains a paucity of literature reporting the differences between individual prosthesis designs with regard to device performance. In this study, the authors evaluated the long-term maintenance of segmental range of motion (ROM) at the operative cervical level across a diverse range of TDA devices. METHODS In this study, the authors retrospectively evaluated all consecutive patients who underwent 1- or 2-level cervical TDA between 2005 and 2020 at a single institution. Patients with a minimum of 6 months of follow-up and lateral flexion/extension radiographs preoperatively, 2 months postoperatively, and at final follow-up were included. Radiographic measurements included static segmental lordosis, segmental range of motion (ROM) on flexion/extension, global cervical (C2-7) ROM on flexion/extension, and disc space height. The paired t-test was used to evaluate improvement in radiographic parameters. Subanalysis between devices was performed using one-way ANCOVA. Significance was determined at p < 0.05. RESULTS A total of 85 patients (100 discs) were included, with a mean patient age of 46.01 ± 8.82 years and follow-up of 43.56 ± 39.36 months. Implantations included 22 (22.00%) M6-C, 51 (51.00%) Mobi-C, 14 (14.00%) PCM, and 13 (13.00%) ProDisc-C devices. There were no differences in baseline radiographic parameters between groups. At 2 months postoperatively, PCM provided significantly less segmental lordosis (p = 0.037) and segmental ROM (p = 0.039). At final follow-up, segmental ROM with both the PCM and ProDisc-C devices was significantly less than that with the M6-C and Mobi-C devices (p = 0.015). From preoperatively to 2 months postoperatively, PCM implantation led to a significant loss of lordosis (p < 0.001) and segmental ROM (p = 0.005) relative to the other devices. Moreover, a significantly greater decline in segmental ROM from 2 months postoperatively to final follow-up was seen with ProDisc-C, while segmental ROM increased significantly over time with Mobi-C (p = 0.049). CONCLUSIONS Analysis by TDA device brand demonstrated that motion preservation differs depending on disc design. Certain devices, including M6-C and Mobi-C, improve ROM on flexion/extension from preoperatively to postoperatively and continue to increase slightly at final follow-up. On the other hand, devices such as PCM and ProDisc-C contributed to greater segmental stiffness, with a gradual decline in ROM seen with ProDisc-C. Further studies are needed to understand how much segmental ROM is ideal after TDA for preservation of physiological cervical kinematics.
Collapse
|
7
|
Chen SR, LeVasseur CM, Pitcairn S, Munsch MA, Couch BK, Kanter AS, Okonkwo DO, Shaw JD, Donaldson WF, Lee JY, Anderst WJ. In Vivo Evidence of Early Instability and Late Stabilization in Motion Segments Immediately Superior to Anterior Cervical Arthrodesis. Spine (Phila Pa 1976) 2022; 47:1234-1240. [PMID: 35794796 PMCID: PMC9378554 DOI: 10.1097/brs.0000000000004388] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Accepted: 04/12/2022] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN Prospective cohort study. OBJECTIVE The aim was to identify patient factors that affect adjacent segment kinematics after anterior cervical discectomy and fusion (ACDF) as measured by biplane radiography. SUMMARY OF BACKGROUND DATA The etiology of adjacent segment disease (ASD) may be multifactorial. Previous studies have investigated associations between patient factors and ASD, although few attempted to link patient factors with mechanical changes in the spine that may explain ASD development. Previous studies manually measured intervertebral motion from static flexion/extension radiographs, however, manual measurements are unreliable, and those studies failed to measure intervertebral motion during rotation. METHODS Patients had continuous cervical spine flexion/extension and axial rotation movements captured at 30 images per second in a dynamic biplane radiography system preoperatively and 1 year after ACDF. Digitally reconstructed radiographs generated from subject-specific computed tomography scans were matched to the biplane radiographs using a validated tracking process. Dynamic kinematics and preoperative disc height were calculated from this tracking process. Preoperative magnetic resonance imagings were evaluated for disc bulge. Patient age, sex, body mass index, smoking status, diabetes, psychiatric history, presence of an inciting event, and length of symptoms were collected. Multivariate linear regression was performed to identify patient factors associated with 1-year postoperative changes in adjacent segment kinematics. RESULTS Sixty-three patients completed preoperative and postoperative testing. Superior adjacent segment disc height and disc bulge predicted the change in superior adjacent segment range of motion after surgery. Inferior adjacent segment disc bulge, smoking history, and the use of psychiatric medications predicted the change in inferior adjacent segment flexion/extension range of motion after surgery. CONCLUSIONS Preexisting adjacent segment disc degeneration, as indicated by disc height and disc bulge, was associated with reduced adjacent segment motion after ACDF, while lack of preexisting adjacent disc degeneration was associated with increased adjacent segment motion after ACDF. These findings provide in vivo evidence supporting early instability and late stabilization in the pathophysiology of disc degeneration.
Collapse
Affiliation(s)
| | | | | | | | | | - Adam S Kanter
- Neurosurgery, University of Pittsburgh Medical Center, Pittsburgh, PA
| | - David O Okonkwo
- Neurosurgery, University of Pittsburgh Medical Center, Pittsburgh, PA
| | | | | | | | | |
Collapse
|
8
|
Nunley P, Schouwen KFV, Stone M. Cervical Total Disc Replacement: Indications and Technique. Neurosurg Clin N Am 2021; 32:419-424. [PMID: 34538468 DOI: 10.1016/j.nec.2021.05.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Cervical total disc replacement devices have been marketed in the United States (US) since 2007, with abundant level 1 evidence published on the treatment. Adherence to the strict inclusion/exclusion criteria and the surgical technique training of the US clinical trials remains the consistent and conservative approach to patient selection and implantation technique. However, patient selection and surgical technique remain debated among US surgeons as the published data and available cervical total disc replacements continue to grow.
Collapse
Affiliation(s)
- Pierce Nunley
- Spine Institute of Louisiana, 1500 Line Avenue, Suite 200, Shreveport, LA 71101, USA.
| | | | - Marcus Stone
- Spine Institute of Louisiana, 1500 Line Avenue, Suite 200, Shreveport, LA 71101, USA
| |
Collapse
|
9
|
Wu TK, Liu H, Ding C, Rong X, He JB, Huang KK, Hong Y, Wang BY. Effect of preoperative segmental range of motion on patient outcomes in cervical disc arthroplasty. BMC Musculoskelet Disord 2020; 21:457. [PMID: 32660463 PMCID: PMC7359220 DOI: 10.1186/s12891-020-03419-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2020] [Accepted: 06/12/2020] [Indexed: 02/08/2023] Open
Abstract
Background Cervical disc arthroplasty (CDA) has been demonstrated, in clinical trials, as an effective and safe treatment for patients diagnosed with radiculopathy and/or myelopathy. However, the current CDA indication criteria, based on the preoperative segmental range of motion (ROM), comprises a wide range of variability. Although the arthroplasty level preserved ROM averages 7°-9° after CDA, there are no clear guidelines on preoperatively limited or excessive ROM at the index level, which could be considered as suitable for CDA. Methods This was a retrospective study of patients who underwent CDA between January 2008 and October 2018 using Prestige-LP discs in our hospital. They were divided into the small-ROM (≤5.5°) and the large-ROM (> 12.5°) groups according to preoperatively index-level ROM. Clinical outcomes, including the Japanese Orthopedics Association (JOA), Neck Disability Index (NDI), and Visual Analogue Scale (VAS) scores, were evaluated. Radiological parameters, including cervical lordosis, disc angle (DA), global and segmental ROM, disc height (DH), and complications were measured. Results One hundred and twenty six patients, with a total of 132 arthroplasty segments were analyzed. There were 64 patients in the small-ROM and 62 in the large-ROM group. There were more patients diagnosed with cervical spondylosis in the small-ROM than in the large-ROM group (P = 0.046). Patients in both groups had significantly improved JOA, NDI, and VAS scores after surgery, but the intergroup difference was not significant. Patients in the small-ROM group had dramatic postoperative increase in cervical lordosis, global and segmental ROM (P < 0.001). However, there was a paradoxical postoperative decrease in global and segmental ROM in the large-ROM group postoperatively (P < 0.001). Patients in the small-ROM group had lower preoperative DH (P = 0.012), and a higher rate of postoperative heterotopic ossification (HO) (P = 0.037). Conclusion Patients with preoperatively limited segmental ROM had severe HO, and achieved similar postoperative clinical outcomes as patients with preoperatively excessive segmental ROM. Patients with preoperatively limited segmental ROM showed a postoperative increase in segmental mobility, which decreased in patients with preoperatively excessive segmental ROM.
Collapse
Affiliation(s)
- Ting-Kui Wu
- Department of Orthopedic Surgery, West China Hospital, Sichuan University, No. 37 Guo Xue Rd, Chengdu, 610041, Sichuan, China
| | - Hao Liu
- Department of Orthopedic Surgery, West China Hospital, Sichuan University, No. 37 Guo Xue Rd, Chengdu, 610041, Sichuan, China
| | - Chen Ding
- Department of Orthopedic Surgery, West China Hospital, Sichuan University, No. 37 Guo Xue Rd, Chengdu, 610041, Sichuan, China
| | - Xin Rong
- Department of Orthopedic Surgery, West China Hospital, Sichuan University, No. 37 Guo Xue Rd, Chengdu, 610041, Sichuan, China
| | - Jun-Bo He
- Department of Orthopedic Surgery, West China Hospital, Sichuan University, No. 37 Guo Xue Rd, Chengdu, 610041, Sichuan, China
| | - Kang-Kang Huang
- Department of Orthopedic Surgery, West China Hospital, Sichuan University, No. 37 Guo Xue Rd, Chengdu, 610041, Sichuan, China
| | - Ying Hong
- Department of Orthopedic Surgery, West China Hospital, Sichuan University, No. 37 Guo Xue Rd, Chengdu, 610041, Sichuan, China
| | - Bei-Yu Wang
- Department of Orthopedic Surgery, West China Hospital, Sichuan University, No. 37 Guo Xue Rd, Chengdu, 610041, Sichuan, China.
| |
Collapse
|
10
|
Song Q, Tian W, He D, Han X, Zhang N, Wang J, Li Z, Feng X. [Analysis of influence of shell angle of cervical artificial disc on long-term effectiveness of cervical artificial disc replacement]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2018; 32:526-530. [PMID: 29806337 DOI: 10.7507/1002-1892.201710083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective To evaluate the influence of the shell angle of cervical artificial disc on long-term effectiveness of cervical artificial disc replacement (CADR). Methods The clinical data of 71 patients who were treated with single-level CADR with Bryan prosthesis between December 2003 and December 2007 and followed up more than 10 years, were retrospectively analyzed. There were 44 males and 27 females with an age of 26-69 years (mean, 45.9 years). According to the shell angle of the cervical artificial disc which was measured on the postoperative lateral X-ray film, the patients were divided into kyphotic group (shell angle was negative) and non-kyphotic group. The following evaluation indexes before operation and at last follow-up were compared between 2 groups. Radiographic indexes included the range of motion (ROM) of cervical spine, the ROM of operated level, Cobb angle of operated level (the negative value indicated that the segmental kyphosis occurred at operated level), paravertebral ossification (PO) grades (grades 3 and 4 were high grade PO). Clinical indexes included Japanese Orthopaedic Association (JOA) score, neck disability index (NDI), and overall effectiveness evaluation (Odom criteria). Results There were 24 patients in kyphotic group and 47 patients in non-kyphotic group. There was no significant difference in baseline data including gender, age, and operated level between 2 groups ( P>0.05). All the patients in 2 groups were followed up 121-165 months (mean, 128 months). There was no significant difference in preoperative ROM of cervical spine and ROM of operated level between 2 groups ( P>0.05); but the preoperative Cobb angle of operated level in kyphosis group was significantly lower than that in non-kyphotic group ( t=2.636, P=0.013). There was no significant difference in ROM of cervical spine at last follow-up between 2 groups ( t=1.393, P=0.168), however, the ROM and the Cobb angle of operated level in kyphotic group were significantly lower than those in non-kyphotic group ( P<0.05). According to the Cobb angle of operated level at last follow-up, there were 9 patients (37.5%) with segmental kyphosis in kyphotic group and 7 patients (14.9%) in non-kyphotic group, showing significant difference ( χ2=4.651, P=0.031). There was a significant difference in PO grades between 2 groups ( Z=2.894, P=0.004) at last follow-up. In kyphotic group, there were 10 patients (41.7%) with low grade PO and 14 patients (58.3%) with high grade PO; and in non-kyphosis group, there were 36 patients (76.6%) with low grade PO and 11 patients (23.4%) with high grade PO. There was no significant difference in JOA scores and NDI before operation and at last follow-up, and the JOA improvement rate, NDI decline, and Odom criteria score at last follow-up between 2 groups ( P>0.05). Conclusion The shell angle of cervical artificial disc may lead to a decrease in the postoperative segmental ROM, and an increased occurrence of segmental kyphosis and high incidence of PO.
Collapse
Affiliation(s)
- Qingpeng Song
- Department of Spine Surgery, Beijing Jishuitan Hospital, Beijing, 100035, P.R.China
| | - Wei Tian
- Department of Spine Surgery, Beijing Jishuitan Hospital, Beijing, 100035,
| | - Da He
- Department of Spine Surgery, Beijing Jishuitan Hospital, Beijing, 100035, P.R.China
| | - Xiao Han
- Department of Spine Surgery, Beijing Jishuitan Hospital, Beijing, 100035, P.R.China
| | - Ning Zhang
- Department of Spine Surgery, Beijing Jishuitan Hospital, Beijing, 100035, P.R.China
| | - Jinchao Wang
- Department of Spine Surgery, Beijing Jishuitan Hospital, Beijing, 100035, P.R.China
| | - Zuchang Li
- Department of Spine Surgery, Beijing Jishuitan Hospital, Beijing, 100035, P.R.China
| | - Xiao Feng
- Department of Spine Surgery, Beijing Jishuitan Hospital, Beijing, 100035, P.R.China
| |
Collapse
|
11
|
Numerical Shape Optimization of Cervical Spine Disc Prosthesis Prodisc-C. JOURNAL OF BIOMIMETICS BIOMATERIALS AND BIOMEDICAL ENGINEERING 2018. [DOI: 10.4028/www.scientific.net/jbbbe.36.56] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Various ball and socket-type designs of cervical artificial discs are in use or under investigation. All these disc designs claim to restore the normal kinematics of the cervical spine. In this study, we are interested in the cervical prosthesis, which concerns the most sensitive part of the human body, given the movements generated by the head. The goal of this work is to minimize the constraints by numerical shape optimization in the prodisc-C cervical spine prosthesis in order to improve performance and bio-functionality as well as patient relief. Prodisc-C cervical spine prosthesis consists of two cobalt chromium alloy plates and a fixed nucleus. Ultra-high molecular weight polyethylene, on each plate there is a keel to stabilize the prosthesis; this prosthesis allows thee degrees of freedom in rotation. To achieve this goal, a static study was carried out to determine the constraint concentrations on the different components of the prosthesis. Based on the biomechanical behaviour of the spine discs, we totally fixed the lower metal plate; a vertical load of 73.6 N to simulate the weight of the head was applied to the superior metallic endplate. After a static study on this prosthesis, using a finite element model, we noticed that the concentration of the Von-Mises stress is concentrated on the peripheral edge core and the concave articulating surface of the superior metallic endplate the numerical. We use the module optimization for 3D SolidWorks for optimize our design, based on the criteria of minimizing stress value. Shape optimization concluded to minimize the equivalent stress value on both joint surface (concave and convex) from 11.3 MPa to 9.1MPa corresponding to a percentage decrease of 19.4% from the original geometry. We conclude that despite the fact that maximum Von Mises stresses are higher in the case of the dynamic load, remains that they are weak. Which is an advantage for the durability of the prosthesis and-also for the bone, because a low stress concentration on the prosthesis will reduce stress concentration generated by the implant on the bone, therefore its risk of fracture reduces.
Collapse
|
12
|
Are Controversial Issues in Cervical Total Disc Replacement Resolved or Unresolved?: A Review of Literature and Recent Updates. Asian Spine J 2018; 12:178-192. [PMID: 29503699 PMCID: PMC5821925 DOI: 10.4184/asj.2018.12.1.178] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2017] [Revised: 07/17/2017] [Accepted: 08/12/2017] [Indexed: 12/17/2022] Open
Abstract
Since the launch of cervical total disc replacement (CTDR) in the early 2000s, many clinical studies have reported better outcomes of CTDR compared to those of anterior cervical discectomy and fusion. However, CTDR is still a new and innovative procedure with limited indications for clinical application in spinal surgery, particularly, for young patients presenting with soft disc herniation with radiculopathy and/or myelopathy. In addition, some controversial issues related to the assessment of clinical outcomes of CTDR remain unresolved. These issues, including surgical outcomes, adjacent segment degeneration (ASD), heterotopic ossification (HO), wear debris and tissue reaction, and multilevel total disc replacement (TDR) and hybrid surgeries are a common concern of spine surgeons and need to be resolved. Among them, the effect of CTDR on patient outcomes and ASD is theoretically and clinically important; however, this issue remains disputable. Additionally, HO, wear debris, multilevel TDR, and hybrid surgery tend to favor CTDR in terms of their effects on outcomes, but the potential of these factors for jeopardizing patients' safety postoperatively and/or to exert harmful effects on surgical outcomes in longer-term follow-up cannot be ignored. Consequently, it is too early to determine the therapeutic efficacy and cost-effectiveness of CTDR and will require considerable time and studies to provide appropriate answers regarding the same. For these reasons, CTDR requires longer-term follow-up data.
Collapse
|
13
|
Zhao J, Jiang R, Yang Y, Gu R, Gao Z, Xiao J, Chen S, Yang M. Preoperative T1 Slope as a Predictor of Change in Cervical Alignment and Range of Motion After Cervical Disc Arthroplasty. Med Sci Monit 2017; 23:5844-5850. [PMID: 29222937 PMCID: PMC5732433 DOI: 10.12659/msm.906944] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
BACKGROUND This study analyzed the effect of preoperative T1 slope on cervical alignment and range of motion (ROM) after cervical disc arthroplasty (CDA) in patients with cervical degenerative disease. MATERIAL AND METHODS This retrospective study included 32 patients with single-level symptomatic cervical disc disease who underwent CDA with the Mobi-C cervical disc prosthesis and had a mean follow-up of 26.8±6.4 months. Standing lateral, flexion, and extension X-rays of the cervical spine were obtained preoperatively and postoperatively at 24-month follow-up. Simple linear regression analysis was used to assess the impact of preoperative T1 slope on changes from preoperative values in radiologic parameters. RESULTS Compared to preoperative values, at 24-month follow-up, there was a significant increase in mean functional spinal unit (FSU) angle (+7.4°), upper adjacent segment (UAS) angle (+3.1°), and overall cervical alignment (C2-C7 angle) (+6.3°), and a significant decrease in mean lower adjacent segment (LAS) angle (-2.4°). Mean ROM of the FSU (-3.6°), LAS (-3.0°), and overall cervical spine (-11.5°) significantly decreased, and mean ROM of the UAS (+1.6°) significantly increased. There were significant correlations between preoperative T1 slope and mean change from preoperative value in FSU angle, C2-C7 angle, and ROM of the overall cervical spine (C2-C7). CONCLUSIONS T1 slope is useful for evaluating changes in the FSU angle, C2-C7 angle, and ROM of the overall cervical spine following CDA with the Mobi-C disc. Patients with a large preoperative T1 slope may be good candidates for CDA with the Mobi-C prosthesis due its motion maintenance and the fact that it has little adverse impact on sagittal alignment. It also could be a good option in terms of sagittal alignment improvement or motion maintenance for patients with kyphosis.
Collapse
Affiliation(s)
- Jianhui Zhao
- Department of Orthopaedics, China-Japan Union Hospital of Jilin University, Changchun, Jilin, China (mainland)
| | - Rui Jiang
- Department of Orthopaedics, China-Japan Union Hospital of Jilin University, Changchun, Jilin, China (mainland)
| | - Yuhui Yang
- Department of Orthopaedics, China-Japan Union Hospital of Jilin University, Changchun, Jilin, China (mainland)
| | - Rui Gu
- Department of Orthopaedics, China-Japan Union Hospital of Jilin University, Changchun, Jilin, China (mainland)
| | - Zhongli Gao
- Department of Orthopaedics, China-Japan Union Hospital of Jilin University, Changchun, Jilin, China (mainland)
| | - Jianlin Xiao
- Department of Orthopaedics, China-Japan Union Hospital of Jilin University, Changchun, Jilin, China (mainland)
| | - Shangjun Chen
- Norman Bethune Medical School, Jilin University, Changchun, Jilin, China (mainland)
| | - Modi Yang
- Department of Orthopaedics, China-Japan Union Hospital of Jilin University, Changchun, Jilin, China (mainland)
| |
Collapse
|
14
|
Analysis of the Factors That Could Predict Segmental Range of Motion After Cervical Artificial Disk Replacement: A 7-Year Follow-up Study. Clin Spine Surg 2017; 30:E603-E608. [PMID: 28525485 DOI: 10.1097/bsd.0000000000000201] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
STUDY DESIGN A retrospective cohort study. OBJECTIVE To identify the potential preoperative factors and surgical technique factors that are associated with long-term range of motion (ROM) after surgery. Further, this article aimed to guide selection of patients with cervical artificial disk replacement and a fine surgical technique. SUMMARY OF BACKGROUND DATA Segmental ROM is the most important parameter concerning cervical kinematics after a cervical artificial disk replacement. There are few researches regarding the influencing factors on postoperative ROM, and consistent results have not yet been reported. METHODS The cohort comprised a total of 68 disks implanted into 57 patients who were retrospectively analyzed. The mean follow-up period was 84.1 months. Segmental ROM and other useful parameters were measured using lateral neutral, extension, and flexion radiographs, which were obtained preoperatively, 3 months after surgery, and at last follow-up. Preoperative CT and clinical assessment were also used. To find out associated factors, the patients were divided into 2 groups according to the segmental ROM at last follow-up. RESULTS After surgery, the clinical outcomes were satisfactory. The segmental ROM at last follow-up (7.8±4.3 degrees) was preserved without significant change from preoperative ROM (8.8±3.8 degrees). The patients who had a better segmental ROM after surgery were found to have a higher preoperative segmental ROM, a younger age, a better disk insertion angle, and disk insertion depth. These 4 factors were identified as independent risk factors (P=0.027, 0.017, 0.036, and 0.046, respectively) for long-term ROM. CONCLUSIONS The postoperative long-term, segmental ROM was well preserved and found to be affected by the preoperative segmental ROM, patient's age, disk insertion angle, and disk insertion depth.
Collapse
|
15
|
Li J, Liang L, Ye XF, Qi M, Chen HJ, Yuan W. Cervical arthroplasty with Discover prosthesis: clinical outcomes and analysis of factors that may influence postoperative range of motion. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2013; 22:2303-9. [PMID: 23877109 DOI: 10.1007/s00586-013-2897-z] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2012] [Revised: 05/05/2013] [Accepted: 07/07/2013] [Indexed: 12/22/2022]
Abstract
PURPOSE The aim of this current study was to analyze the clinical outcomes after Discover cervical disc replacement and its effects on maintaining cervical lordosis and range of motion (ROM). The possible factors influencing postoperative ROM were analyzed. METHOD 27 men and 28 women with a mean age of 46.4 ± 8.7 years were prospectively followed up for 2 years. Clinical outcomes were assessed using Japanese Orthopedic Association (JOA), Neck Disability Index (NDI), visual analog scale (VAS) and Odom's criteria. Radiographic information including segment and overall alignment, functional spinal unit (FSU) and overall ROM, and disc heights were prospectively collected during the follow-up. The correlations between the postoperative FSU ROM at last follow-up and influencing factors were analyzed. RESULTS Mean NDI, JOA and VAS scores showed statistical improvements at last follow-up. Anterior migration of the prosthesis was detected in six cases. Heterotopic ossification was observed in ten patients. Mean FSU angle, endplate angle of the treated level and mean overall cervical alignment were all improved significantly at last follow-up (P < 0.001). However, mean FSU ROM of the treated segment significantly decreased postoperatively (P = 0.008), while mean overall ROM showed no significant differences. A significant correlation was found between preoperative FSU ROM and postoperative FSU ROM by the Pearson correlation coefficient (r = 0.325, P = 0.034). Multiple linear regression analysis confirmed that preoperative FSU ROM contributed independently to a model with a coefficient of determination of 0.37 (P = 0.034). CONCLUSIONS In the 2 years follow-up, the Discover cervical disc arthroplasty has provided satisfactory clinical outcomes. It was able to substantially restore segment and overall cervical alignment while partially maintaining segment and overall cervical ROM. Additionally, we found that postoperative FSU ROM positively correlated with preoperative FSU ROM.
Collapse
Affiliation(s)
- Jun Li
- Department of Orthopaedic Surgery, Changzheng Hospital of the Second Military Medical University, Shanghai, 200003, China
| | | | | | | | | | | |
Collapse
|
16
|
Ryu WHA, Kowalczyk I, Duggal N. Long-term kinematic analysis of cervical spine after single-level implantation of Bryan cervical disc prosthesis. Spine J 2013; 13:628-34. [PMID: 23578991 DOI: 10.1016/j.spinee.2013.02.046] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2011] [Revised: 07/10/2012] [Accepted: 02/18/2013] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT Cervical arthroplasty theoretically reduces the risk of adjacent level disc degeneration and segmental instability that may be seen after a cervical fusion. An essential argument in confirming the utility of cervical arthroplasty is long-term confirmation that cervical disc replacements can maintain physiological kinematics at the index and adjacent levels. PURPOSE The purpose of this in vivo prospective study was to characterize the long-term segmental kinematic outcomes after cervical arthroplasty. STUDY DESIGN/SETTING Prospective cohort study. PATIENT SAMPLE Twenty patients with a 5-year clinical follow-up who underwent anterior cervical discectomy with insertion of the Bryan cervical disc. OUTCOME MEASURES Physiological measures (kinematic analysis of lateral neutral, flexion, and extension radiographic imaging). METHODS Twenty consecutive patients with degenerative disc disease were followed with regular radiographic imaging after implantation of the Bryan cervical disc prosthesis. Lateral neutral, flexion, and extension radiographs (n=240) were analyzed using Quantitative Motion Analysis software (Medical Metrics, Inc., Houston, TX, USA) to measure the biomechanical profile at the index level and adjacent levels up to 5 years after surgery. Parameters collected included range of motion (ROM), functional spinal unit (FSU) angle, anterior and posterior disc heights, sagittal translation, and center of rotation (COR). RESULTS Biomechanics of the implanted artificial cervical disc was maintained up to 5 years with no significant changes in ROM, FSU angle, disc height, sagittal translation, and COR values when compared with early postoperative performance. Artificial discs were able to adequately restore and maintain preoperative kinematics. Early differences seen in disc height and FSU angle did not change during the duration of follow-up. No significant kyphotic changes or decrease in ROM were seen at the adjacent spinal levels. CONCLUSIONS The Bryan cervical disc prosthesis provides for a durable solution for functional spinal motion at the operated level and maintained the preoperative kinematics at adjacent levels at the 5-year follow-up.
Collapse
Affiliation(s)
- Won Hyung A Ryu
- Schulich School of Medicine & Dentistry, University of Western Ontario, London, Ontario, Canada
| | | | | |
Collapse
|
17
|
Clinical and radiological follow-up of single-level Prestige LP cervical disc replacement. Arch Orthop Trauma Surg 2013; 133:473-80. [PMID: 23392650 DOI: 10.1007/s00402-013-1689-6] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2012] [Indexed: 02/09/2023]
Abstract
OBJECTIVE To evaluate the clinical outcomes and radiographic results of patients who underwent single-level cervical arthroplasty using the Prestige LP. METHOD Thirty-one patients with single-level cervical disc disease received the Prestige LP disc replacement from June 2008 to December 2009. The neck disability index (NDI), Japanese Orthopedic Association score (JOA) and visual analogue scale (VAS) were used to assessed clinical outcomes pre-operatively and post-operatively at 24 months. The overall cervical alignment (C2-7 Cobb angle), the functional segmental unit (FSU) curvature, the range of motion (ROM) of treated and adjacent levels were measured, and the evidence of heterotopic ossification (HO) was observed from static and dynamic radiographs. RESULTS There was a statistically significant improvement in the NDI from 20.2 ± 7.5 to 6.4 ± 3.5 (P < 0.000), JOA from 12.8 ± 2.2 to 16.6 ± 0.6 (P < 0.000), the neck VAS score from 4.1 ± 2.5 to 1.4 ± 1.1 (P < 0.000), the arm VAS score from 4.6 ± 2.5 to 0.7 ± 1.1 (P < 0.000). The post-operative overall cervical alignment (9.3° ± 7.2°), ROM of treated level (7.6°) and adjacent level (upper level 9.4° ± 3.1°, lower level 9.1° ± 3.5°) are well maintained. The FSU were 0.2° ± 5.4° and 1.9° ± 5.5° at pre-operation and final follow-up with statistical significance (P = 0.011). Heterotopic ossification was evidenced in five operated segment (16 %). CONCLUSIONS The Prestige LP disc arthroplasty maintains favorable clinical outcomes, preserves the overall cervical alignment, FSU curvature, ROM of treated level and adjacent levels.
Collapse
|