1
|
Mikhail J, Funabashi M, Sobczak S, Descarreaux M, Pagé I. Investigation of the factors influencing spinal manipulative therapy force transmission through the thorax: a cadaveric study. Chiropr Man Therap 2023; 31:24. [PMID: 37550682 PMCID: PMC10405484 DOI: 10.1186/s12998-023-00493-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Accepted: 06/16/2023] [Indexed: 08/09/2023] Open
Abstract
BACKGROUND Spinal manipulative therapy (SMT) clinical effects are believed to be linked to its force-time profile characteristics. Previous studies have revealed that the force measured at the patient-table interface is most commonly greater than the one applied at the clinician-patient interface. The factors explaining this force amplification remains unclear. OBJECTIVE To determine the difference between the force applied to a cadaveric specimen's thoracic spine and the resulting force measured by a force-sensing table, as well as to evaluate the relationship between this difference and both the SMT force-time characteristics and the specimens' characteristics. METHODS Twenty-five SMTs with different force-time profiles were delivered by an apparatus at the T7 vertebra of nine human cadaveric specimens lying prone on a treatment table equipped with a force plate. The difference between the force applied by the apparatus and the resulting force measured by the force plate was calculated in absolute force (Fdiff) and as the percentage of the applied force (Fdiff%). Kinematics markers were inserted into T6 to T8 spinous and transverse processes to evaluate vertebral displacements during the SMT thrusts. Mixed-effects linear models were run to evaluate the variance in Fdiff and Fdiff% explained by SMT characteristics (peak force, thrust duration and force application rate), T6 to T8 relative and total displacements, and specimens' characteristics (BMI, height, weight, kyphosis angle, thoracic thickness). RESULTS Sixty percent of the trials showed lower force measured at the force plate than the one applied at T7. Fdiff¸ was significantly predicted (R2marginal = 0.54) by peak force, thrust duration, thoracic thickness and T6-T7 relative displacement in the z-axis (postero-anterior). Fdiff% was significantly predicted (R2marginal = 0.56) by force application rate, thoracic thickness and total T6 displacements. For both dependant variables, thoracic thickness showed the highest R2marginal out of all predictors. CONCLUSION Difference in force between the clinician-patient and the patient-table interfaces is influenced by SMT force-time characteristics and by thoracic thickness. How these differences in force are associated with vertebral displacements remains unclear. Although further studies are needed, clinicians should consider thorax thickness as a possible modulator of forces being transmitted through it during prone SMT procedures.
Collapse
Affiliation(s)
- Jérémie Mikhail
- Department of Chiropractic, Université du Québec à Trois-Rivières, 3351 Boul. des Forges, Trois-Rivières, QC, G8Z 4M3, Canada
- Research Group on Neuromusculoskeletal Disorders, Université du Québec à Trois-Rivières, 3351 Boul. des Forges, Trois-Rivières, QC, G8Z 4M3, Canada
| | - Martha Funabashi
- Department of Chiropractic, Université du Québec à Trois-Rivières, 3351 Boul. des Forges, Trois-Rivières, QC, G8Z 4M3, Canada
- Canadian Memorial Chiropractic College, 6100 Leslie St, North York, ON, M2H 3J1, Canada
| | - Stéphane Sobczak
- Research Group on Neuromusculoskeletal Disorders, Université du Québec à Trois-Rivières, 3351 Boul. des Forges, Trois-Rivières, QC, G8Z 4M3, Canada
- Department of Anatomy, Université du Québec à Trois-Rivières, 3351 Boul. des Forges, Trois-Rivières, QC, G8Z 4M3, Canada
- Research Chair in Functional Anatomy, Université du Québec à Trois-Rivières, 3351 Boul. des Forges, QC, G8Z 4M3, Trois-Rivières, Canada
| | - Martin Descarreaux
- Research Group on Neuromusculoskeletal Disorders, Université du Québec à Trois-Rivières, 3351 Boul. des Forges, Trois-Rivières, QC, G8Z 4M3, Canada
- Department of Human Kinetics, Université du Québec à Trois-Rivières, 3351 Boul. des Forges, Trois-Rivières, QC, G8Z 4M3, Canada
| | - Isabelle Pagé
- Department of Chiropractic, Université du Québec à Trois-Rivières, 3351 Boul. des Forges, Trois-Rivières, QC, G8Z 4M3, Canada.
- Research Group on Neuromusculoskeletal Disorders, Université du Québec à Trois-Rivières, 3351 Boul. des Forges, Trois-Rivières, QC, G8Z 4M3, Canada.
- Center for Interdisciplinary Research in Rehabilitation and Social Integration (Cirris), Centre Intégré Universitaire de Santé et de Services Sociaux de la Capitale-Nationale (CIUSSS-CN), 525 Boul. Wilfrid-Hamel, Québec City, QC, G1M 2S8, Canada.
| |
Collapse
|
2
|
Reed WR, Lima CR, Liebschner MAK, Hurt CP, Li P, Gudavalli MR. Measurement of Force and Intramuscular Pressure Changes Related to Thrust Spinal Manipulation in an In Vivo Animal Model. BIOLOGY 2022; 12:biology12010062. [PMID: 36671758 PMCID: PMC9855381 DOI: 10.3390/biology12010062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 12/23/2022] [Accepted: 12/28/2022] [Indexed: 01/03/2023]
Abstract
Current knowledge regarding biomechanical in vivo deep tissue measures related to spinal manipulation remain somewhat limited. More in vivo animal studies are needed to better understand the effects viscoelastic tissue properties (i.e., dampening) have on applied spinal manipulation forces. This new knowledge may eventually help to determine whether positive clinical outcomes are associated with particular force thresholds reaching superficial and/or deep spinal tissues. A computer-controlled feedback motor and a modified Activator V device with a dynamic load cell attached were used to deliver thrust spinal manipulations at various magnitudes to the L7 spinous process in deeply anesthetized animals. Miniature pressure catheters (Millar SPR-1000) were inserted unilaterally into superficial and deep multifidi muscles. Measurements of applied mechanical forces and superficial/deep multifidi intramuscular pressure changes were recorded during spinal manipulations delivered in vivo. Manipulative forces and net changes in intramuscular pressures reaching deep spinal tissues are greatly diminished by viscoelastic properties of in vivo tissues, which could have possible clinical safety and/or mechanistic implications.
Collapse
Affiliation(s)
- William R. Reed
- Department of Physical Therapy, University of Alabama at Birmingham, Birmingham, AL 35294, USA
- Correspondence:
| | - Carla R. Lima
- Rehabilitation Sciences Program, University of Alabama at Birmingham, Birmingham, AL 35294, USA
| | | | - Christopher P. Hurt
- Department of Physical Therapy, University of Alabama at Birmingham, Birmingham, AL 35294, USA
| | - Peng Li
- School of Nursing, University of Alabama at Birmingham, Birmingham, AL 35294, USA
| | - Maruti R. Gudavalli
- College of Chiropractic Medicine, Keiser University, West Palm Beach, FL 33411, USA
| |
Collapse
|
3
|
In vivo measurement of intradiscal pressure changes related to thrust and non-thrust spinal manipulation in an animal model: a pilot study. Chiropr Man Therap 2022; 30:36. [PMID: 36068588 PMCID: PMC9446573 DOI: 10.1186/s12998-022-00445-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Accepted: 08/01/2022] [Indexed: 12/29/2022] Open
Abstract
BACKGROUND The intervertebral disc is a known back pain generator and is frequently the focus of spinal manipulative therapy evaluation and treatment. The majority of our current knowledge regarding intradiscal pressure (IDP) changes related to spinal manual therapy involves cadaveric studies with their inherent limitations. Additional in vivo animal models are needed to investigate intervertebral disc physiological and molecular mechanisms related to spinal manipulation and spinal mobilization treatment for low back disorders. METHODS Miniature pressure catheters (Millar SPR-1000) were inserted into either the L4-L5 or L5-L6 intervertebral disc of 3 deeply anesthetized adult cats (Oct 2012-May 2013). Changes in IDP were recorded during delivery of instrument-assisted spinal manipulation (Activator V® and Pulstar®) and motorized spinal flexion with/without manual spinous process contact. RESULTS Motorized flexion of 30° without spinous contact decreased IDP of the L4-L5 disc by ~ 2.9 kPa, while physical contact of the L4 spinous process decreased IDP an additional ~ 1.4 kPa. Motorized flexion of 25° with L5 physical contact in a separate animal decreased IDP of the L5-L6 disc by ~ 1.0 kPa. Pulstar® impulses (setting 1-3) increased IDP of L4-L5 and L5-L6 intervertebral discs by ~ 2.5 to 3.0 kPa. Activator V® (setting 1-4) impulses increased L4-L5 IDP to a similar degree. Net changes in IDP amplitudes remained fairly consistent across settings on both devices regardless of device setting suggesting that viscoelastic properties of in vivo spinal tissues greatly dampen superficially applied manipulative forces prior to reaching deep back structures such as the intervertebral disc. CONCLUSIONS This study marks the first time that feline in vivo changes in IDP have been reported using clinically available instrument-assisted spinal manipulation devices and/or spinal mobilization procedures. The results of this pilot study indicate that a feline model can be used to investigate IDP changes related to spinal manual therapy mechanisms as well as the diminution of these spinal manipulative forces due to viscoelastic properties of the surrounding spinal tissues. Additional investigation of IDP changes is warranted in this and/or other in vivo animal models to provide better insights into the physiological effects and mechanisms of spinal manual therapy at the intervertebral disc level.
Collapse
|
4
|
Funabashi M, Breen AC, De Carvalho D, Pagé I, Nougarou F, Descarreaux M, Kawchuk GN. Force Distribution Within Spinal Tissues During Posterior to Anterior Spinal Manipulative Therapy: A Secondary Analysis. Front Integr Neurosci 2022; 15:809372. [PMID: 35185486 PMCID: PMC8855051 DOI: 10.3389/fnint.2021.809372] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Accepted: 12/31/2021] [Indexed: 12/20/2022] Open
Abstract
Background Previous studies observed that the intervertebral disc experiences the greatest forces during spinal manipulative therapy (SMT) and that the distribution of forces among spinal tissues changes as a function of the SMT parameters. However, contextualized SMT forces, relative to the ones applied to and experienced by the whole functional spinal unit, is needed to understand SMT’s underlying mechanisms. Aim To describe the percentage force distribution between spinal tissues relative to the applied SMT forces and total force experienced by the functional unit. Methods This secondary analysis combined data from 35 fresh porcine cadavers exposed to a simulated 300N SMT to the skin overlying the L3/L4 facet joint via servo-controlled linear motor actuator. Vertebral kinematics were tracked optically using indwelling bone pins. The functional spinal unit was then removed and mounted on a parallel robotic platform equipped with a 6-axis load cell. The kinematics of the spine during SMT were replayed by the robotic platform. By using serial dissection, peak and mean forces induced by the simulated SMT experienced by spinal structures in all three axes of motion were recorded. Forces experienced by spinal structures were analyzed descriptively and the resultant force magnitude was calculated. Results During SMT, the functional spinal unit experienced a median peak resultant force of 36.4N (IQR: 14.1N) and a mean resultant force of 25.4N (IQR: 11.9N). Peak resultant force experienced by the spinal segment corresponded to 12.1% of the total applied SMT force (300N). When the resultant force experienced by the functional spinal unit was considered to be 100%, the supra and interspinous ligaments experienced 0.3% of the peak forces and 0.5% of the mean forces. Facet joints and ligamentum flavum experienced 0.7% of the peak forces and 3% of the mean forces. Intervertebral disc and longitudinal ligaments experienced 99% of the peak and 96.5% of the mean forces. Conclusion In this animal model, a small percentage of the forces applied during a posterior-to-anterior SMT reached spinal structures in the lumbar spine. Most SMT forces (over 96%) are experienced by the intervertebral disc. This study provides a novel perspective on SMT force distribution within spinal tissues.
Collapse
Affiliation(s)
- Martha Funabashi
- Division of Research and Innovation, Canadian Memorial Chiropractic College, Toronto, ON, Canada
- Chiropractic Department, Université du Québec à Trois-Rivières, Trois-Rivières, QC, Canada
- *Correspondence: Martha Funabashi,
| | | | - Diana De Carvalho
- Faculty of Medicine, Memorial University of Newfoundland, St. John’s, NL, Canada
| | - Isabelle Pagé
- Chiropractic Department, Université du Québec à Trois-Rivières, Trois-Rivières, QC, Canada
| | - François Nougarou
- Department of Electrical and Computer Engineering, Université du Québec à Trois-Rivières, Trois-Rivières, QC, Canada
| | - Martin Descarreaux
- Human Kinetics Department, Université du Québec à Trois-Rivières, Trois-Rivières, QC, Canada
| | - Gregory N. Kawchuk
- Department of Physical Therapy, University of Alberta, Edmonton, AB, Canada
| |
Collapse
|
5
|
Mercier MA, Rousseau P, Funabashi M, Descarreaux M, Pagé I. Devices Used to Measure Force-Time Characteristics of Spinal Manipulations and Mobilizations: A Mixed-Methods Scoping Review on Metrologic Properties and Factors Influencing Use. FRONTIERS IN PAIN RESEARCH 2021; 2:755877. [PMID: 35295511 PMCID: PMC8915691 DOI: 10.3389/fpain.2021.755877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Accepted: 10/06/2021] [Indexed: 11/13/2022] Open
Abstract
Background: Spinal manipulations (SMT) and mobilizations (MOB) are interventions commonly performed by many health care providers to manage musculoskeletal conditions. The clinical effects of these interventions are believed to be, at least in part, associated with their force-time characteristics. Numerous devices have been developed to measure the force-time characteristics of these modalities. The use of a device may be facilitated or limited by different factors such as its metrologic properties.Objectives: This mixed-method scoping review aimed to characterize the metrologic properties of devices used to measure SMT/MOB force-time characteristics and to determine which factors may facilitate or limit the use of such devices within the context of research, education and clinical practice.Methods: This study followed the Joanna Briggs Institute's framework. The literature search strategy included four concepts: (1) devices, (2) measurement of SMT or MOB force-time characteristics on humans, (3) factors facilitating or limiting the use of devices, and (4) metrologic properties. Two reviewers independently reviewed titles, abstracts and full articles to determine inclusion. To be included, studies had to report on a device metrologic property (e.g., reliability, accuracy) and/or discuss factors that may facilitate or limit the use of the device within the context of research, education or clinical practice. Metrologic properties were extracted per device. Limiting and facilitating factors were extracted and themes were identified.Results: From the 8,998 studies initially retrieved, 46 studies were finally included. Ten devices measuring SMT/MOB force-time characteristics at the clinician-patient interface and six measuring them at patient-table interfaces were identified. Between zero and eight metrologic properties were reported per device: measurement error (defined as validity, accuracy, fidelity, or calibration), reliability/repeatability, coupling/crosstalk effect, linearity/correlation, sensitivity, variability, drift, and calibration. From the results, five themes related to the facilitating and limiting factors were developed: user-friendliness and versatility, metrologic/intrinsic properties, cost and durability, technique application, and feedback.Conclusion: Various devices are available to measure SMT/MOB force-time characteristics. Metrologic properties were reported for most devices, but terminology standardization is lacking. The usefulness of a device in a particular context should be determined considering the metrologic properties as well as other potential facilitating and limiting factors.
Collapse
Affiliation(s)
- Marie-Andrée Mercier
- Chiropractic Department, Université du Québec à Trois-Rivières, Trois-Rivières, QC, Canada
| | - Philippe Rousseau
- Chiropractic Department, Université du Québec à Trois-Rivières, Trois-Rivières, QC, Canada
| | - Martha Funabashi
- Chiropractic Department, Université du Québec à Trois-Rivières, Trois-Rivières, QC, Canada
- Canadian Memorial Chiropractic College, Toronto, ON, Canada
| | - Martin Descarreaux
- Human Kinetics Department, Université du Québec à Trois-Rivières, Trois-Rivières, QC, Canada
| | - Isabelle Pagé
- Chiropractic Department, Université du Québec à Trois-Rivières, Trois-Rivières, QC, Canada
- Center for Interdisciplinary Research in Rehabilitation and Social Integration (CIRRIS), Québec, QC, Canada
- *Correspondence: Isabelle Pagé
| |
Collapse
|
6
|
Effects of biomechanical parameters of spinal manipulation: A critical literature review. JOURNAL OF INTEGRATIVE MEDICINE-JIM 2021; 20:4-12. [PMID: 34756673 DOI: 10.1016/j.joim.2021.10.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Accepted: 08/10/2021] [Indexed: 11/23/2022]
Abstract
Spinal manipulation is a manual treatment technique that delivers a thrust, using specific biomechanical parameters to exert its therapeutic effects. These parameters have been shown to have a unique dose-response relationship with the physiological responses of the therapy. So far, however, there has not been a unified approach to standardize these biomechanical characteristics. In fact, it is still undetermined how they affect the observed clinical outcomes of spinal manipulation. This study, therefore, reviewed the current body of literature to explore these dosage parameters and evaluate their significance, with respect to physiological and clinical outcomes. From the experimental studies reviewed herein, it is evident that the modulation of manipulation's biomechanical parameters elicits transient physiological responses, including changes in neuronal activity, electromyographic responses, spinal stiffness, muscle spindle responses, paraspinal muscle activity, vertebral displacement, and segmental and intersegmental acceleration responses. However, to date, there have been few clinical trials that tested the therapeutic relevance of these changes. In addition, there were some inherent limitations in both human and animal models due to the use of mechanical devices to apply the thrust. Future studies evaluating the effects of varying biomechanical parameters of spinal manipulation should include clinicians to deliver the therapy in order to explore the true clinical significance of the dose-response relationship.
Collapse
|
7
|
Funabashi M, Son J, Pecora CG, Tran S, Lee J, Howarth SJ, Kawchuk G, de Luca K. Characterization of thoracic spinal manipulation and mobilization forces in older adults. Clin Biomech (Bristol, Avon) 2021; 89:105450. [PMID: 34450432 DOI: 10.1016/j.clinbiomech.2021.105450] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 07/13/2021] [Accepted: 08/11/2021] [Indexed: 02/07/2023]
Abstract
BACKGROUND Spinal mobilization and spinal manipulation are common interventions used by manual therapists to treat musculoskeletal conditions in older adults. Their force-time characteristics applied to older adults' thoracic spine are important considerations for effectiveness and safety but remain unknown. This study aimed to describe the force-time characteristics of posterior-to-anterior spinal mobilization and manipulation delivered to older adults' thoracic spine. METHODS Twenty-one older adults (≥65 years) with no thoracic pain received posterior-to-anterior thoracic spinal mobilization and/or manipulation with the force characteristics a chiropractor deemed appropriate. Six-degree-of-freedom load cells and an instrumented treatment table recorded the force characteristics of both interventions at the clinician-participant and participant-table interfaces, respectively. Preload force, total peak force, time to peak and loading rate were analyzed descriptively. FINDINGS Based on data from 18 adults (56% female; average: 70 years old), mean resultant spinal mobilization forces at the clinician-participant interface were: 220 ± 51 N during preload, 323 ± 67 N total peak force, and 312 ± 38 ms time to peak. At the participant-table interface, mobilization forces were 201 ± 50 N during preload, 296 ± 63 N total peak force, and 308 ± 44 ms time to peak. Mean resultant spinal manipulation forces at the clinician-participant interface were: 260 ± 41 N during preload, 470 ± 46 N total peak force, and 165 ± 28 ms time to peak. At the participant table interface, spinal manipulation forces were 236 ± 47 N during preload, 463 ± 57 N total peak force, and 169 ± 28 ms time to peak. INTERPRETATION Results suggest older adults experience unique, but comparable force-time characteristics during spinal mobilization and manipulation delivered to their thoracic spine compared to the ones delivered to younger adults described in the literature.
Collapse
Affiliation(s)
- Martha Funabashi
- Division of Research and Innovation, Canadian Memorial Chiropractic College, 6100 Leslie St., Toronto, ON M2H 3J1, Canada; Department of Chiropractic, Université du Québec à Trois-Rivières, 3351 boulevard des Forges, Trois-Rivières, QC G9A 5H7, Canada.
| | - James Son
- Division of Research and Innovation, Canadian Memorial Chiropractic College, 6100 Leslie St., Toronto, ON M2H 3J1, Canada.
| | - Cosma Gary Pecora
- Division of Research and Innovation, Canadian Memorial Chiropractic College, 6100 Leslie St., Toronto, ON M2H 3J1, Canada.
| | - Steve Tran
- Division of Research and Innovation, Canadian Memorial Chiropractic College, 6100 Leslie St., Toronto, ON M2H 3J1, Canada.
| | - Joyce Lee
- Division of Research and Innovation, Canadian Memorial Chiropractic College, 6100 Leslie St., Toronto, ON M2H 3J1, Canada.
| | - Samuel J Howarth
- Division of Research and Innovation, Canadian Memorial Chiropractic College, 6100 Leslie St., Toronto, ON M2H 3J1, Canada.
| | - Gregory Kawchuk
- Department of Physical Therapy, University of Alberta, 8205 114 St, 3-48 Corbett Hall, Edmonton, AB T6G 2G4, Canada.
| | - Katie de Luca
- Department of Chiropractic, Macquarie University, Balaclava Road, North Ryde, Sydney, NSW 2109, Australia.
| |
Collapse
|
8
|
Characteristics of Forces at the Clinician–Patient and Patient–Table Interfaces During Thoracic Spinal Manipulation in Asymptomatic Adults Are Consistent With Deformable Body Models. J Appl Biomech 2021; 38:39-46. [DOI: 10.1123/jab.2021-0255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Revised: 11/04/2021] [Accepted: 12/08/2021] [Indexed: 11/18/2022]
Abstract
Investigating all forces exerted on the patient’s body during high-velocity, low-amplitude spinal manipulative therapy (SMT) remains fundamental to elucidate how these may contribute to SMT’s effects. Previous conflicting findings preclude our understanding of the relationship between SMT forces acting at the clinician–patient and patient–table interfaces. This study aimed to quantify forces at the clinician–participant and participant–table interfaces during thoracic SMT in asymptnomatic adults. An experienced clinician provided a posterior to anterior SMT centered to T7 transverse processes using predetermined force–time characteristics to 40 asymptomatic volunteers (20 females; average age = 27.2 [4.9] y). Forces at the clinician–participant interface were recorded by triaxial load cells; whereas, forces at the participant–table interface were recorded by the force-sensing table technology. Preload force, total peak force, time to peak, and loading rate at each interface were analyzed descriptively. Total peak vertical forces at the clinician–participant interface averaged 532 (71) N while total peak forces at the participant–table interface averaged 658 (33) N. Forces at the participant–table interface were, on average, 1.27 (0.25) times larger than the ones at the clinician–participant interface. Larger forces at the participant–table interface compared with the ones at the clinician–participant interface during thoracic SMT are consistent with mathematical models developed to investigate thoracic impact simulating a dynamic force-deflection response.
Collapse
|
9
|
Tuttle N, Hazle C. An empirical, pragmatic approach applying reflection in interaction approach to manual therapy treatments. Physiother Theory Pract 2019; 37:775-786. [PMID: 31385748 DOI: 10.1080/09593985.2019.1650405] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Background: Most literature on decision processes within physiotherapy relates to "reasoning that results in action" - decisions based on information including assessments that are gathered prior to treatment decisions. A process of "reasoning in interaction" that is often used, particularly by expert clinicians, has received less attention. Objective: To provide a theoretical and practical approach to applying reasoning in interaction in a musculoskeletal setting. Methods: The theory is: If an impairment that can be directly targeted by treatment (i.e. pain or limitation of passive movement) is related to patient's active impairments and functional limitations, then moment-to-moment changes in the targeted impairment can be used as feedback to guide real-time treatment modification before formal reassessment of functional limitations and other impairments. Results: Applying the theory to manual therapy results in parameters of techniques such as force, speed, direction and duration no longer being pre-determined, but rather being continually adjusted in real-time according to feedback from the patient through both therapist perception (changes in movement quantity or quality) and patient verbal responses. Conclusion: A process of continuous decision-making is described that the authors believe is used by many experienced clinicians but has not previously been adequately described in the literature. .
Collapse
Affiliation(s)
- Neil Tuttle
- School of Allied Health Sciences, Griffith University, Gold Coast, Australia
| | - Charles Hazle
- Division of Physical Therapy, Center for Rural Health, University of Kentucky, Hazard, Kentucky, USA
| |
Collapse
|
10
|
Picchiottino M, Leboeuf-Yde C, Gagey O, Hallman DM. The acute effects of joint manipulative techniques on markers of autonomic nervous system activity: a systematic review and meta-analysis of randomized sham-controlled trials. Chiropr Man Therap 2019; 27:17. [PMID: 30911373 PMCID: PMC6413458 DOI: 10.1186/s12998-019-0235-1] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Accepted: 01/16/2019] [Indexed: 12/19/2022] Open
Abstract
Background The autonomic nervous system (ANS) interests many chiropractors and manual therapists, because joint manipulative techniques (JMT), e.g. high velocity low amplitude (HVLA) manipulations and mobilizations, appear to produce acute changes in ANS mediated physiology. The complexity of this issue justifies a systematic critical literature review. Objective To review the literature comparing the acute changes in markers of ANS activity between JMT applied on spinal or peripheral joints and a sham procedure in healthy or symptomatic subjects. Method We searched PsycINFO, PEDro, PubMed, Cochrane library, EMBASE, and Medline up to December 2017. We updated the search with PubMed, Cochrane library, EMBASE, and Medline including July 2018. Inclusion criteria were: randomized sham-controlled trials assessing the effect of JMT on markers of ANS activity; manually applied JMT, regardless of technique, applied on either healthy or symptomatic humans; outcome measurements recorded at baseline and repeated during and/or after interventions. Selection of articles and data extraction were performed independently by two reviewers. The quality of studies was assessed using the Cochrane ‘risk of bias’ tool and a technical check-list. Results were reported narratively with some meta-analyses. The Cochrane GRADE approach was used to assess the certainty of evidence. Results Twenty-nine of 2267 studies were included in the synthesis. Mobilizations (oscillatory technique) probably produce an immediate and short-term, bilateral increase in skin sympathetic nerve activity (reflected by an increase in skin conductance) regardless of the area treated (moderate-certainty evidence). It is uncertain whether the sympathetic arousal also explains an increase in respiratory rate (very low-certainty evidence). Our evaluation of the literature suggests that spinal sustained apophyseal glides (SNAGs) mobilization and HVLA manipulation of the spine may have no acute effect on the studied markers of ANS activity (very low- to low-certainty evidence). Conclusion Some types of mobilizations probably produce an immediate and short-term, statistically significant increase in skin sympathetic nerve activity when compared to a sham procedure, whereas spinal SNAGs and spinal HVLA techniques may have no acute effect on the studied markers of ANS activity. No region-specific results were noted. The literature suffers from several shortcomings, for which reason we strongly suggest further research. Electronic supplementary material The online version of this article (10.1186/s12998-019-0235-1) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Mathieu Picchiottino
- 1CIAMS, Université Paris-Sud, Université Paris-Saclay, Orsay Cedex, France.,2CIAMS, Université d'Orléans, Orléans, France.,Institut Franco-européen de Chiropraxie (IFEC), Ivry-sur-Seine, France
| | - Charlotte Leboeuf-Yde
- 1CIAMS, Université Paris-Sud, Université Paris-Saclay, Orsay Cedex, France.,2CIAMS, Université d'Orléans, Orléans, France.,Institut Franco-européen de Chiropraxie (IFEC), Ivry-sur-Seine, France.,4Institute for Regional Health Research, University of Southern Denmark, Odense, Denmark
| | - Olivier Gagey
- 1CIAMS, Université Paris-Sud, Université Paris-Saclay, Orsay Cedex, France.,2CIAMS, Université d'Orléans, Orléans, France
| | - David M Hallman
- 5Centre for Musculoskeletal Research, Department of Occupational and Public Health Sciences, University of Gävle, Gävle, Sweden
| |
Collapse
|