• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4608468)   Today's Articles (2648)   Subscriber (49375)
For: Chee G. Development and characterization of microbial biosensors for evaluating low biochemical oxygen demand in rivers. Talanta 2013;117:366-70. [DOI: 10.1016/j.talanta.2013.09.031] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2013] [Revised: 09/17/2013] [Accepted: 09/18/2013] [Indexed: 11/20/2022]
Number Cited by Other Article(s)
1
Kharkova A, Perchikov R, Kurbanalieva S, Osina K, Popova N, Machulin A, Kamanina O, Saverina E, Saltanov I, Melenkov S, Butusov D, Arlyapov V. Targeted Formation of Biofilms on the Surface of Graphite Electrodes as an Effective Approach to the Development of Biosensors for Early Warning Systems. BIOSENSORS 2024;14:239. [PMID: 38785713 PMCID: PMC11118945 DOI: 10.3390/bios14050239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Revised: 04/30/2024] [Accepted: 05/01/2024] [Indexed: 05/25/2024]
2
Arlyapov VA, Plekhanova YV, Kamanina OA, Nakamura H, Reshetilov AN. Microbial Biosensors for Rapid Determination of Biochemical Oxygen Demand: Approaches, Tendencies and Development Prospects. BIOSENSORS 2022;12:842. [PMID: 36290979 PMCID: PMC9599453 DOI: 10.3390/bios12100842] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 09/23/2022] [Accepted: 10/01/2022] [Indexed: 06/16/2023]
3
Sonawane JM, Ezugwu CI, Ghosh PC. Microbial Fuel Cell-Based Biological Oxygen Demand Sensors for Monitoring Wastewater: State-of-the-Art and Practical Applications. ACS Sens 2020;5:2297-2316. [PMID: 32786393 DOI: 10.1021/acssensors.0c01299] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
4
Wang S, Zu L, Miao Y, Fei C, Zhang H, Li B, Zhang K, Liu F. Simultaneous measurement of the BOD concentration and temperature based on a tapered microfiber for water pollution monitoring. APPLIED OPTICS 2020;59:7364-7370. [PMID: 32902504 DOI: 10.1364/ao.396831] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Accepted: 07/26/2020] [Indexed: 06/11/2023]
5
Aksorn J, Teepoo S. Development of the simultaneous colorimetric enzymatic detection of sucrose, fructose and glucose using a microfluidic paper-based analytical device. Talanta 2020;207:120302. [DOI: 10.1016/j.talanta.2019.120302] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Revised: 08/26/2019] [Accepted: 08/27/2019] [Indexed: 02/05/2023]
6
Plekhanova YV, Reshetilov AN. Microbial Biosensors for the Determination of Pesticides. JOURNAL OF ANALYTICAL CHEMISTRY 2019. [DOI: 10.1134/s1061934819120098] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
7
Nakamura H. Current status of water environment and their microbial biosensor techniques - Part II: Recent trends in microbial biosensor development. Anal Bioanal Chem 2018;410:3967-3989. [PMID: 29736704 DOI: 10.1007/s00216-018-1080-0] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Revised: 04/07/2018] [Accepted: 04/12/2018] [Indexed: 12/20/2022]
8
Li Y, Sun J, Wang J, Bian C, Tong J, Li Y, Xia S. A microbial electrode based on the co-electrodeposition of carboxyl graphene and Au nanoparticles for BOD rapid detection. Biochem Eng J 2017. [DOI: 10.1016/j.bej.2017.03.015] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
9
Bahadır EB, Sezgintürk MK. Applications of commercial biosensors in clinical, food, environmental, and biothreat/biowarfare analyses. Anal Biochem 2015;478:107-20. [DOI: 10.1016/j.ab.2015.03.011] [Citation(s) in RCA: 253] [Impact Index Per Article: 28.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2015] [Revised: 03/03/2015] [Accepted: 03/06/2015] [Indexed: 11/24/2022]
10
Liu L, Zhai J, Zhu C, Gao Y, Wang Y, Han Y, Dong S. One-pot synthesis of 3-dimensional reduced graphene oxide-based hydrogel as support for microbe immobilization and BOD biosensor preparation. Biosens Bioelectron 2015;63:483-489. [DOI: 10.1016/j.bios.2014.07.074] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2014] [Revised: 07/21/2014] [Accepted: 07/23/2014] [Indexed: 11/28/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA