1
|
Rahman N, Ahmad I. Coordination polymer gel mediated spectrophotometric, ICP-AES and spectrofluorimetric methods for trace As(III) determination in water and food samples. CHEMOSPHERE 2024; 351:141272. [PMID: 38262491 DOI: 10.1016/j.chemosphere.2024.141272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 01/11/2024] [Accepted: 01/19/2024] [Indexed: 01/25/2024]
Abstract
Herein, a coordination polymer gel is proposed for the determination of As(III) in real samples through multispectroscopic techniques viz. spectrophotometry, spectrofluorimetry, and inductively coupled plasma atomic emission spectroscopy (ICP-AES). Taguchi L32 (46 21) design and adaptive neuro fuzzy inference system (ANFIS) optimized the controllable factors affecting the extraction yielding an experimental S/N ratio of 39.94 dB. The fluorescence quenching (KSV = 2.63 × 106 L mol-1) was static with photoelectron transfer being the main mechanism confirmed by the density functional theory calculations. The limits of detection (LODs), limits of quantification (LOQs) and linear ranges were 0.038 μg L-1, 0.13 μg L-1 and 1.67-116.67 μg L-1, 0.40 μg L-1, 1.21 μg L-1 and 1.67-33.33 μg L-1, 1.07 μg L-1, 3.24 μg L-1 and 3.32-35.37 μg L-1 for the developed enrichment coupled ICP-AES, spectrophotometry and fluorescence sensing methods. Among these methods, the enrichment - ICP-AES method has the lowest LOD, LOQ and the widest linear range followed by the enrichment - spectrophotometry and fluorescene sensing methods. Spectrofluorimetry offers high sensitivity, selectivity, and possible real time monitoring, spectrophotometry provides a cost-effective and versatile option, while ICP-AES manifests multi-element analysis with high sensitivity and low interference. The developed methods were validated and employed for the successful determination of trace As(III) in real samples. The employment of these methods enhances the overall analytical capability for a wide range of sample types and concentrations.
Collapse
Affiliation(s)
- Nafisur Rahman
- Department of Chemistry Aligarh Muslim University, Aligarh-202002, India.
| | - Izhar Ahmad
- Department of Chemistry Aligarh Muslim University, Aligarh-202002, India
| |
Collapse
|
2
|
Proch J, Niedzielski P. Recent applications of continuous flow chemical vapor and hydride generation (CVG, HG) coupled to plasma–based optical emission spectrometry (ICP OES, MIP OES). Talanta 2022; 243:123372. [DOI: 10.1016/j.talanta.2022.123372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 03/05/2022] [Accepted: 03/07/2022] [Indexed: 10/18/2022]
|
3
|
Ahmad H, Koo BH, Khan RA. Magnetite β-lactoglobulin@Fe3O4 nanocomposite for the extraction and preconcentration of As(III) species. Microchem J 2022. [DOI: 10.1016/j.microc.2021.106941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
4
|
Elik A, Tuzen M, Hazer B, Kaya S, Katin KP, Altunay N. Development of sensitive and accurate solid-phase microextraction procedure for preconcentration of As(III) ions in real samples. Sci Rep 2021; 11:5481. [PMID: 33750835 PMCID: PMC7970910 DOI: 10.1038/s41598-021-84819-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2020] [Accepted: 02/08/2021] [Indexed: 12/31/2022] Open
Abstract
We synthesized the poly(methyl methacrylate-co-2-aminoethyl methacrylate (PMaema) amphiphilic copolymer in a form of solid phase adsorbent. Then it was used for separation, preconcentration and determination of trace amount of As(III) ions from foods and waters with hydride generation atomic absorption spectrometry. The PMaema was characterized by fourier transform infrared spectrometer and nuclear magnetic resonance spectrometer. The adsorption of As(III) to the PMaema was also supported using computational chemistry studies. The experimental parameters (pH, PMaema amount, adsorption time and ethanol volume) were optimized using a three-level Box-Behnken design with four experimental factors. We observed linear calibration curve for the PMaema amount in the 10-500 ng L-1 range (R2 = 0.9956). Limit of detection, preconcentration factor and sorbent capacity of PMaema were equal to 3.3 ng L-1, 100 and 75.8 mg g-1, respectively. The average recoveries (spiked at 50 ng L-1) changes in the range of 91.5-98.6% with acceptable relative standard deviation less than 4.3%. After validation studies, the method was successfully applied for separation, preconcentration and determination of trace amount of As(III) from foods and waters.
Collapse
Affiliation(s)
- Adil Elik
- Department of Chemistry, Sivas Cumhuriyet University, 58140, Sivas, Turkey
| | - Mustafa Tuzen
- Faculty of Science and Arts, Chemistry Department, Tokat Gaziosmanpasa University, 60250, Tokat, Turkey.
- Center for Environment and Water, King Fahd University of Petroleum and Minerals, Research Institute, Dhahran, 31261, Saudi Arabia.
| | - Baki Hazer
- Department of Aircraft Airframe Engine Maintenance, Kapadokya University, Urgup, 50420, Nevşehir, Turkey
- Chemistry Department, Zonguldak Bulent Ecevit University, 67100, Zonguldak, Turkey
| | - Savaş Kaya
- Health Services Vocational School, Department of Pharmacy, Sivas Cumhuriyet University, 58140, Sivas, Turkey
| | - K P Katin
- Institute of Nanoengineering in Electronics, Spintronics and Photonics, National Research Nuclear University "MEPhI", Kashirskoe Shosse 31, Moscow, 115409, Russia
| | - Nail Altunay
- Department of Biochemistry, Sivas Cumhuriyet University, TR-58140, Sivas, Turkey.
| |
Collapse
|
5
|
Selective determination of As(III) and total inorganic arsenic in rice sample using in-situ μ-sorbent formation solid phase extraction and FI-HG AAS. J Food Compost Anal 2021. [DOI: 10.1016/j.jfca.2020.103686] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
6
|
Ahmad H, Haseen U, Umar K, Ansari MS, Ibrahim MNM. Bioinspired 2D carbon sheets decorated with MnFe2O4 nanoparticles for preconcentration of inorganic arsenic, and its determination by ICP-OES. Mikrochim Acta 2019; 186:649. [DOI: 10.1007/s00604-019-3753-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Accepted: 08/10/2019] [Indexed: 01/07/2023]
|
7
|
Ceria nanoparticles deposited on graphene nanosheets for adsorption of copper(II) and lead(II) ions and of anionic species of arsenic and selenium. Mikrochim Acta 2018; 185:264. [PMID: 29687427 PMCID: PMC5913377 DOI: 10.1007/s00604-018-2806-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2017] [Accepted: 04/13/2018] [Indexed: 11/04/2022]
Abstract
A nanocomposite prepared from graphene nanosheets and cerium nanoparticles (G/CeO2) was applied to the extraction of Se(IV), As(V), As(III), Cu(II) and Pb(II). The structure of G/CeO2 was investigated by scanning electron microscopy, X-ray diffraction and Raman spectroscopy. The optimal pH values for extraction are 4.0 for As(V), 3.0 for Se(IV), and 6.0 for both Cu(II) and Pb(II). The maximum adsorption capacity of G/CeO2 (expressed as mg·g−1) were calculated by the Langmuir model and are found to be 8.4 for As(V), 14.1 for Se(IV), 50.0 for Cu(II) and 75.6 for Pb(II). The sorbent was applied to dispersive solid phase microextraction prior to direct quantitation by energy-dispersive X-ray fluorescence spectrometry without the need for prior elution. The limits of detection (in ng·mL−1 units) are 0.10 for As(V), 0.11 for Se(IV), 0.19 for Cu(II) and 0.21 for Pb(II). The precisions (RSDs) are <4.5%. The accuracy of the method (1 - 4%) was verified by analysis of the certified reference material (CRM 1640a - natural water). The method was successfully applied in ultratrace element determination and to the speciation of selenium in environmental waters. The method gives possibility of simultaneous preconcentration and determination in environmental waters of both anionic (As(V) and Se(IV)) and cationic (Cu(II) and Pb(II)) forms of selected metals using graphene nanosheets and cerium nanoparticles. Se(IV) can be selective determined in the presence of Se(VI). ![]()
Collapse
|
8
|
Amorim FAC, Costa VC, Silva EGPD, Lima DDC, Jesus RMD, Bezerra MDA. Multivariate optimization of simple procedure for determination of Fe and Mg in cassava starch employing slurry sampling and FAAS. Food Chem 2017; 227:41-47. [DOI: 10.1016/j.foodchem.2016.12.029] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2015] [Revised: 11/29/2016] [Accepted: 12/10/2016] [Indexed: 02/08/2023]
|
9
|
Llorente-Mirandes T, Rubio R, López-Sánchez JF. Inorganic Arsenic Determination in Food: A Review of Analytical Proposals and Quality Assessment Over the Last Six Years. APPLIED SPECTROSCOPY 2017; 71:25-69. [PMID: 28033722 DOI: 10.1177/0003702816652374] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Here we review recent developments in analytical proposals for the assessment of inorganic arsenic (iAs) content in food products. Interest in the determination of iAs in products for human consumption such as food commodities, wine, and seaweed among others is fueled by the wide recognition of its toxic effects on humans, even at low concentrations. Currently, the need for robust and reliable analytical methods is recognized by various international safety and health agencies, and by organizations in charge of establishing acceptable tolerance levels of iAs in food. This review summarizes the state of the art of analytical methods while highlighting tools for the assessment of quality assessment of the results, such as the production and evaluation of certified reference materials (CRMs) and the availability of specific proficiency testing (PT) programmes. Because the number of studies dedicated to the subject of this review has increased considerably over recent years, the sources consulted and cited here are limited to those from 2010 to the end of 2015.
Collapse
Affiliation(s)
| | - Roser Rubio
- Department of Analytical Chemistry, University of Barcelona, Spain
| | | |
Collapse
|
10
|
Chen S, Qin X, Gu W, Zhu X. Speciation analysis of Mn(II)/Mn(VII) using Fe3O4@ionic liquids-β-cyclodextrin polymer magnetic solid phase extraction coupled with ICP-OES. Talanta 2016; 161:325-332. [DOI: 10.1016/j.talanta.2016.08.062] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2016] [Revised: 08/19/2016] [Accepted: 08/21/2016] [Indexed: 10/21/2022]
|
11
|
Chatzimitakos T, Binellas C, Maidatsi K, Stalikas C. Magnetic ionic liquid in stirring-assisted drop-breakup microextraction: Proof-of-concept extraction of phenolic endocrine disrupters and acidic pharmaceuticals. Anal Chim Acta 2016; 910:53-9. [PMID: 26873468 DOI: 10.1016/j.aca.2016.01.015] [Citation(s) in RCA: 69] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2015] [Revised: 01/04/2016] [Accepted: 01/08/2016] [Indexed: 01/16/2023]
Abstract
The use of magnetic ionic liquids (MILs) is in constant growth due to their switchable properties in the presence of an external magnetic field along with the outstanding properties of ionic liquids. In this study, a novel stirring-assisted drop-breakup microextraction (SADBME) approach is put forward, based on the synthesis and utilization of methyltrioctylammonium tetrachloroferrate (N8 8,8,1[FeCl4]), as a MIL. The proposed procedure complies with the principles of the green chemistry, since it uses low volumes of easily synthesized ILs-based magnetic extracting phases avoiding the use of toxic solvents. To demonstrate its applicability, the proposed microextraction procedure is studied in conjunction with HPLC for the determination of selected phenols and acidic pharmaceuticals in aqueous matrices, taking into account the main experimental variables involved. The results obtained are accurate and highly reproducible, thus making it a good alternative approach for routine analysis of phenols and acidic pharmaceuticals. The low-cost approach is straightforward, environmentally safe and exhibits high enrichment factors and absolute extraction percentages and satisfactory recoveries. To the best of our knowledge, this is the first time that a MIL is used for analytical purposes in a practical, efficient and environmentally friendly drop-breakup microextraction approach for small molecules.
Collapse
Affiliation(s)
- Theodoros Chatzimitakos
- Laboratory of Analytical Chemistry, Department of Chemistry, University of Ioannina, 451 10 Ioannina, Greece
| | - Charalampos Binellas
- Laboratory of Analytical Chemistry, Department of Chemistry, University of Ioannina, 451 10 Ioannina, Greece
| | - Katerina Maidatsi
- Laboratory of Analytical Chemistry, Department of Chemistry, University of Ioannina, 451 10 Ioannina, Greece
| | - Constantine Stalikas
- Laboratory of Analytical Chemistry, Department of Chemistry, University of Ioannina, 451 10 Ioannina, Greece.
| |
Collapse
|