1
|
Cortés-Bautista S, Molins-Legua C, Campíns-Falcó P. Miniaturized liquid chromatography in environmental analysis. A review. J Chromatogr A 2024; 1730:465101. [PMID: 38941795 DOI: 10.1016/j.chroma.2024.465101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 06/14/2024] [Accepted: 06/16/2024] [Indexed: 06/30/2024]
Abstract
The greater and more widespread use of chemicals, either from industry or daily use, is leading to an increase in the discharge of these substances into the environment. Some of these are known to be hazardous to humans and the environment and are regulated, but there is a large and increasing number of substances which pose a potential risk even at low concentration and are not controlled. In this context, new techniques and methodologies are being developed to deal with this concern. Miniaturized liquid chromatography (LC) emerges as a greener and more sensitive alternative to conventional LC. Furthermore, advances in instrument miniaturization have made possible the development of portable LC instrumentation which may become a promising tool for in-situ monitoring. This work reviews the environmental applications of miniaturized LC over the last 15 years and discusses the different instrumentation, including off- and on-line pretreatment techniques, chromatographic conditions, and contributions to the environmental knowledge.
Collapse
Affiliation(s)
- S Cortés-Bautista
- Department Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain
| | - C Molins-Legua
- Department Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain.
| | - P Campíns-Falcó
- Department Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain.
| |
Collapse
|
2
|
Duny M, Cortéjade A, Wiest L, Nicolas M, Vulliet E. Single injection LC-MS/MS analytical method for the quantification of diverse families of micropollutants, including PFAS and organotins, in Gammarus fossarum. J Chromatogr A 2024; 1720:464778. [PMID: 38432107 DOI: 10.1016/j.chroma.2024.464778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 02/23/2024] [Accepted: 02/27/2024] [Indexed: 03/05/2024]
Abstract
Since the last decades, light has been shed on the pollution of aquatic ecosystems. Considering apolar compounds in water, analysis of the dissolved phase is not sufficient due to their possible bioaccumulation. Additional analysis of sediments, biota, or sentinel species is necessary. Among sentinel species, Gammarus fossarum is a small shrimp of 30 mg that lives naturally in the river. Its ability to bioaccumulate makes it a good bioindicator of river pollution. Nevertheless, micropollutants are difficult to extract from gammarids due to their small size and their high level of lipids. Extracted interferences can lead to analytical difficulties. Targeted micropollutants in this work were organotins, personal and pharmaceutical care products (PPCPs), pesticides, flame retardants, and perfluorinated compounds. A sample preparation based on QuEChERS followed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) was developed: different salts (acetate and citrate) and purification (addition of hexane, dispersive SPE) were tested and validated. Targeted molecules used to be analyzed by LC-MS/MS, except organotins which are principally analyzed in gas chromatography. One of the main challenges was to quantify them also in LC-MS/MS to implement an original multi-residue method. The analysis of 40 compounds was finally validated according to ICH guidelines, with LOQs ranging from 0.04 ng.g-1 to 313.5 ng.g-1. Regarding Perfluorooctanesulfonic acid (PFOS) and the sum of hexabromocyclododecane, LOQs reached the environmental quality standards in biota which are respectively of 9.1 and 167 ng.g-1. Finally, the method was applied to 15 real samples. Many compounds were quantified: perfluorinated compounds, drugs such as ketoprofen, and even cosmetics products such as octocrylene. This is the first study to quantify as many emerging compounds, especially organotins, in a sentinel species such as G. fossarum.
Collapse
Affiliation(s)
- Mathilde Duny
- CARSO-LSEHL, 4 avenue Jean Moulin, Vénissieux 69633, France; Universite Claude Bernard Lyon 1 ISA, UMR 5280 CNRS, 5 rue de la Doua, Villeurbanne 69100, France
| | | | - Laure Wiest
- Universite Claude Bernard Lyon 1 ISA, UMR 5280 CNRS, 5 rue de la Doua, Villeurbanne 69100, France
| | | | - Emmanuelle Vulliet
- Universite Claude Bernard Lyon 1 ISA, UMR 5280 CNRS, 5 rue de la Doua, Villeurbanne 69100, France.
| |
Collapse
|
3
|
Hicks MB, Mattern K, Fine J, Grosser S, Patel D, Weisel L, Aggarwal P. Portable capillary LC for in-line UV monitoring and MS detection: Comparable sensitivity and much lower solvent consumption. J Sep Sci 2023; 46:e2300300. [PMID: 37715328 DOI: 10.1002/jssc.202300300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Revised: 08/26/2023] [Accepted: 08/29/2023] [Indexed: 09/17/2023]
Abstract
Pharmaceutical development currently relies on quality separation methods from early discovery through to line-of-site manufacturing. There have been significant advancements made regarding the column particle packing, internal diameter, length connectivity, the understanding of the impact key parameters like void volume, flow rate, and temperature all that affects the resultant separation quality, that is, resolution, peak shape, peak width, run time, and signal-to-noise ratio. There is however a strong need to establish better alternatives to large bulky high-performance liquid chromatography racks either for process analytical reaction monitoring or mass spectrometry analysis in establishing product quality. Compact, portable high-pressure liquid chromatography can be a more efficient alternative to traditional ultra-high pressure liquid chromatography and traditional liquid chromatography. The compact versatile instrument evaluated here allows good separation control with either the on-board column with fixed ultra-violet wavelength cartridge or for use with a high-resolution mass spectrometry. Significant space reduction results in greener lab spaces with improved energy efficiency for smaller labs with lower energy demands. In addition, this compact liquid chromatography was used as a portable reaction monitoring solution to compare forced degradation kinetics and assess portable liquid chromatography-mass spectrometry capability for the analyses required for pharmaceutical drug product testing.
Collapse
Affiliation(s)
- Michael B Hicks
- Analytical Research & Development, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - Keith Mattern
- Process Enabling Technologies, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - Jonathan Fine
- Analytical Research & Development, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - Shane Grosser
- Process Enabling Technologies, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - Daya Patel
- Analytical Research & Development, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - Lauren Weisel
- Analytical Research & Development, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - Pankaj Aggarwal
- Analytical Research & Development, MRL, Merck & Co., Inc., Massachusetts, Boston, USA
| |
Collapse
|
4
|
Godfrey AR, Dunscombe J, Gravell A, Hunter A, Barrow MP, van Keulen G, Desbrow C, Townsend R. Use of QuEChERS as a manual and automated high-throughput protocol for investigating environmental matrices. CHEMOSPHERE 2022; 308:136313. [PMID: 36067814 DOI: 10.1016/j.chemosphere.2022.136313] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Revised: 08/18/2022] [Accepted: 08/30/2022] [Indexed: 06/15/2023]
Abstract
Environmental pollution has strong links to adverse human health outcomes with risks of pollution through production, use, ineffective wastewater (WW) remediation, and/or leachate from landfill. 'Fit-for-purpose' monitoring approaches are critical for better pollution control and mitigation of harm, with current sample preparation methods for complex environmental matrices typically time-consuming and labour intensive, unsuitable for high-throughput screening. This study has shown that a modified 'Quick Easy Cheap Effective Rugged and Safe' (QuEChERS) sample preparation is a viable alternative for selected environmental matrices required for pollution monitoring (e.g. WW effluent, treated sludge cake and homogenised biota tissue). As a manual approach, reduced extraction times (hours to ∼20 min/sample) with largely reproducible (albeit lower) recoveries of a range of pharmaceuticals and biocidal surfactants have been reported. Its application has shown clear differentiation of matrices via chemometrics, and the measurement of pollutants of interest to the UK WW industry at concentrations significantly above suggested instrument detection limits (IDL) for sludge, indicating insufficient removal and/or bioaccumulation during WW treatment. Furthermore, new pollutant candidates of emerging concern were identified - these included detergents, polymers and pharmaceuticals, with quaternary ammonium compound (QAC) biocides observed at 2.3-70.4 mg/kg, and above levels associated with priority substances for environmental quality regulation (EQSD). Finally, the QuEChERS protocol was adapted to function as a fully automated workflow, further reducing the resource to complete both the preparation and analysis to <40 min. This operated with improved recovery for soil and biota (>62%), and when applied to a largely un-investigated clay matrix, acceptable recovery (88.0-131.1%) and precision (≤10.3% RSD) for the tested pharmaceuticals and biocides was maintained. Therefore, this preliminary study has shown the successful application of a high-throughput QuEChERS protocol across a range of environmental solids for potential deployment in a regulated laboratory.
Collapse
Affiliation(s)
- A Ruth Godfrey
- Swansea University Medical School, Singleton Park, Swansea, SA2 8PP, UK.
| | | | - Anthony Gravell
- Natural Resources Wales Analytical Services, Singleton Park, Swansea, SA2 8PP, UK
| | - Ann Hunter
- Swansea University Medical School, Singleton Park, Swansea, SA2 8PP, UK
| | - Mark P Barrow
- Department of Chemistry, University of Warwick, Coventry, CV4 7AL, UK
| | | | - Claire Desbrow
- Biotage GB Limited, Dyffryn Business Park, Hengoed, CF82 7TS, UK
| | - Rachel Townsend
- Swansea University Medical School, Singleton Park, Swansea, SA2 8PP, UK
| |
Collapse
|
5
|
Wicht AJ, Heye K, Schmidt A, Oehlmann J, Huhn C. The wastewater micropollutant carbamazepine in insectivorous birds-an exposure estimate. Anal Bioanal Chem 2022; 414:4909-4917. [PMID: 35581428 PMCID: PMC9234033 DOI: 10.1007/s00216-022-04117-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 04/28/2022] [Accepted: 05/04/2022] [Indexed: 11/25/2022]
Abstract
Insects with aquatic life stages can transfer sediment and water pollutants to terrestrial ecosystems, which has been described for metals, polyaromatic hydrocarbons, and polychlorinated chemicals. However, knowledge of the transfer of aquatic micropollutants released by wastewater treatment plants is scarce despite some preliminary studies on their occurrence in riparian spiders. In our study, we address a major analytical gap focusing on the transfer of the micropollutant carbamazepine from the larvae to the adult midges of Chironomus riparius using an optimized QuEChERS extraction method and HPLC–MS/MS applicable to both life stages down to the level of about three individuals. We show that the uptake of carbamazepine by larvae is concentration-dependent and reduces the emergence rate. Importantly, the body burden remained constant in adult midges. Using this information, we estimated the daily exposure of insectivorous tree swallows as terrestrial predators to carbamazepine using the energy demand of the predator and the energy content of the prey. Assuming environmentally relevant water concentrations of about 1 μg/L, the daily dose per kilogram of body weight for tree swallows was estimated to be 0.5 μg/kg/day. At places of high water contamination of 10 μg/L, the exposure may reach 5 μg/kg/day for this micropollutant of medium polarity. Considering body burden changes upon metamorphosis, this study fills the missing link between aquatic contamination and exposure in terrestrial habitats showing that wastewater pollutants can impact birds’ life. Clearly, further analytical methods for biota analysis in both habitats are urgently required to improve risk assessment.
Collapse
Affiliation(s)
- Anna-Jorina Wicht
- Institute of Physical and Theoretical Chemistry, Eberhard Karls Universität Tübingen, Tübingen, Germany
- Bayerisches Landesamt für Umwelt, Augsburg, Germany
| | - Katharina Heye
- Department Aquatic Ecotoxicology, Goethe-Universität Frankfurt, Frankfurt, Germany
| | - Anja Schmidt
- Department Aquatic Ecotoxicology, Goethe-Universität Frankfurt, Frankfurt, Germany
| | - Jörg Oehlmann
- Department Aquatic Ecotoxicology, Goethe-Universität Frankfurt, Frankfurt, Germany
| | - Carolin Huhn
- Institute of Physical and Theoretical Chemistry, Eberhard Karls Universität Tübingen, Tübingen, Germany.
| |
Collapse
|
6
|
Green Extraction Techniques as Advanced Sample Preparation Approaches in Biological, Food, and Environmental Matrices: A Review. MOLECULES (BASEL, SWITZERLAND) 2022; 27:molecules27092953. [PMID: 35566315 PMCID: PMC9101692 DOI: 10.3390/molecules27092953] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 04/28/2022] [Accepted: 05/02/2022] [Indexed: 12/13/2022]
Abstract
Green extraction techniques (GreETs) emerged in the last decade as greener and sustainable alternatives to classical sample preparation procedures aiming to improve the selectivity and sensitivity of analytical methods, simultaneously reducing the deleterious side effects of classical extraction techniques (CETs) for both the operator and the environment. The implementation of improved processes that overcome the main constraints of classical methods in terms of efficiency and ability to minimize or eliminate the use and generation of harmful substances will promote more efficient use of energy and resources in close association with the principles supporting the concept of green chemistry. The current review aims to update the state of the art of some cutting-edge GreETs developed and implemented in recent years focusing on the improvement of the main analytical features, practical aspects, and relevant applications in the biological, food, and environmental fields. Approaches to improve and accelerate the extraction efficiency and to lower solvent consumption, including sorbent-based techniques, such as solid-phase microextraction (SPME) and fabric-phase sorbent extraction (FPSE), and solvent-based techniques (μQuEChERS; micro quick, easy, cheap, effective, rugged, and safe), ultrasound-assisted extraction (UAE), and microwave-assisted extraction (MAE), in addition to supercritical fluid extraction (SFE) and pressurized solvent extraction (PSE), are highlighted.
Collapse
|
7
|
Fedorenko D, Bartkevics V. Recent Applications of Nano-Liquid Chromatography in Food Safety and Environmental Monitoring: A Review. Crit Rev Anal Chem 2021; 53:98-122. [PMID: 34392753 DOI: 10.1080/10408347.2021.1938968] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
In recent years, a trend toward instrument miniaturization has led to the development of new and sophisticated analytical systems, such as nano-liquid chromatography (nano-LC), which has enabled improvements of sensitivity, as well as chromatographic resolution. The growing interest in nano-LC methodology has resulted in a variety of innovative and promising applications. In this article, we review the applications of nano-LC separation methods coupled with mass spectrometry in the analysis of food and environmental samples. An assessment of sample preparation methods and analytical performance are provided, along with comparison to other, more established analytical techniques. Three main groups of compounds that are crucial for food safety assessment are considered in this review: pharmaceuticals (including antibiotics), pesticides, and mycotoxins. Recent practical applications of the nano-LC method in the determination of these compounds are discussed. Furthermore, we also focus on methods for the determination of various environmental contaminants using nano-LC methods. Future perspectives for the development of nano-LC methods are discussed.
Collapse
Affiliation(s)
- Deniss Fedorenko
- Institute of Food Safety, Animal Health and Environment "BIOR", Riga, Latvia.,University of Latvia, Faculty of Chemistry, Riga, Latvia
| | - Vadims Bartkevics
- Institute of Food Safety, Animal Health and Environment "BIOR", Riga, Latvia.,University of Latvia, Faculty of Chemistry, Riga, Latvia
| |
Collapse
|
8
|
Development of a method for assessing the accumulation and metabolization of antidepressant drugs in zebrafish (Danio rerio) eleutheroembryos. Anal Bioanal Chem 2021; 413:5169-5179. [PMID: 34195876 PMCID: PMC8405463 DOI: 10.1007/s00216-021-03486-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 06/09/2021] [Accepted: 06/16/2021] [Indexed: 11/25/2022]
Abstract
Antidepressant drugs are widely used for the treatment of common mental or other psychiatric disorders such as depression, which affect about 121 million people worldwide. This widespread use has contributed to the input of these pharmaceuticals and their metabolites into the environment. The aim of this work was to develop an analytical method to quantify the most widely used antidepressant drugs, selective serotonin reuptake inhibitors (SSRI), and their main metabolites in the environment. For this, a new and reliable miniaturized extraction method based on dispersive SPE cleanup procedure for extraction of SSRI followed by derivatization with n-heptafluorobutyrylimidazole, and detection by GC-MS was developed. The methodology, including a first-order one-compartment model, was then applied to a bioconcentration study in zebrafish (Danio rerio) eleutheroembryos. The results showed low bioaccumulation of these compounds; however, a biotransformation evidence of the parent compounds into their metabolites was observed after 6 h of exposure. These results indicate the need to integrate metabolic transformation rates to fully model and understand the bioaccumulation patterns of SSRI and their metabolites. Graphical abstract ![]()
Collapse
|
9
|
Omar TFT, Aris AZ, Yusoff FM. Multiclass analysis of emerging organic contaminants in tropical marine biota using improved QuEChERS extraction followed by LC MS/MS. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106063] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
10
|
Knoll S, Rösch T, Huhn C. Trends in sample preparation and separation methods for the analysis of very polar and ionic compounds in environmental water and biota samples. Anal Bioanal Chem 2020; 412:6149-6165. [PMID: 32710277 PMCID: PMC7442764 DOI: 10.1007/s00216-020-02811-5] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Revised: 06/29/2020] [Accepted: 07/08/2020] [Indexed: 12/25/2022]
Abstract
Recent years showed a boost in knowledge about the presence and fate of micropollutants in the environment. Instrumental and methodological developments mainly in liquid chromatography coupled to mass spectrometry hold a large share in this success story. These techniques soon complemented gas chromatography and enabled the analysis of more polar compounds including pesticides but also household chemicals, food additives, and pharmaceuticals often present as traces in surface waters. In parallel, sample preparation techniques evolved to extract and enrich these compounds from biota and water samples. This review article looks at very polar and ionic compounds using the criterion log P ≤ 1. Considering about 240 compounds, we show that (simulated) log D values are often even lower than the corresponding log P values due to ionization of the compounds at our reference pH of 7.4. High polarity and charge are still challenging characteristics in the analysis of micropollutants and these compounds are hardly covered in current monitoring strategies of water samples. The situation is even more challenging in biota analysis given the large number of matrix constituents with similar properties. Currently, a large number of sample preparation and separation approaches are developed to meet the challenges of the analysis of very polar and ionic compounds. In addition to reviewing them, we discuss some trends: for sample preparation, preconcentration and purification efforts by SPE will continue, possibly using upcoming mixed-mode stationary phases and mixed beds in order to increase comprehensiveness in monitoring applications. For biota analysis, miniaturization and parallelization are aspects of future research. For ionic or ionizable compounds, we see electromembrane extraction as a method of choice with a high potential to increase throughput by automation. For separation, predominantly coupled to mass spectrometry, hydrophilic interaction liquid chromatography applications will increase as the polarity range ideally complements reversed phase liquid chromatography, and instrumentation and expertise are available in most laboratories. Two-dimensional applications have not yet reached maturity in liquid-phase separations to be applied in higher throughput. Possibly, the development and commercial availability of mixed-mode stationary phases make 2D applications obsolete in semi-targeted applications. An interesting alternative will enter routine analysis soon: supercritical fluid chromatography demonstrated an impressive analyte coverage but also the possibility to tailor selectivity for targeted approaches. For ionic and ionizable micropollutants, ion chromatography and capillary electrophoresis are amenable but may be used only for specialized applications such as the analysis of halogenated acids when aspects like desalting and preconcentration are solved and the key advantages are fully elaborated by further research. Graphical abstract.
Collapse
Affiliation(s)
- Sarah Knoll
- Institute of Physical and Theoretical Chemistry, Eberhard Karls Universität Tübingen, Auf der Morgenstelle 18, Tübingen, Germany
| | - Tobias Rösch
- Institute of Physical and Theoretical Chemistry, Eberhard Karls Universität Tübingen, Auf der Morgenstelle 18, Tübingen, Germany
| | - Carolin Huhn
- Institute of Physical and Theoretical Chemistry, Eberhard Karls Universität Tübingen, Auf der Morgenstelle 18, Tübingen, Germany.
| |
Collapse
|
11
|
Al-Alam J, Baroudi F, Chbani A, Fajloun Z, Millet M. A multiresidue method for the analysis of pesticides, polycyclic aromatic hydrocarbons, and polychlorinated biphenyls in snails used as environmental biomonitors. J Chromatogr A 2020; 1621:461006. [PMID: 32156459 DOI: 10.1016/j.chroma.2020.461006] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Revised: 02/28/2020] [Accepted: 03/02/2020] [Indexed: 01/14/2023]
Abstract
This paper reports an optimized multiresidue extraction strategy based on the Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) extraction procedure and on solid-phase microextraction (SPME) for the simultaneous screening of 120 pesticides, 16 polycyclic aromatic hydrocarbons, and 22 polychlorinated biphenyls from the terrestrial snail Helix aspersa. The optimized extraction method was based on QuEChERS using acetonitrile, followed by dispersive-Solid-phase extraction clean-up using primary secondary amine and octadecyl (C18) sorbents. The obtained extracts were analyzed by liquid chromatography coupled with tandem mass spectrometry and gas chromatography coupled with tandem mass spectrometry. This latest technique was preceded by a pre-concentration step using SPME with appropriate fibers. Afterwards, the method was validated for its linearity, sensitivity, recovery, and precision. Results showed high sensitivity, accuracy, and precision, with limits of detection and quantification lower than 20 ng g - 1 for most considered pollutants. Both inter and intra-day analyses revealed low relative standard deviation (%), which was lower than 20% for most targeted compounds. Moreover, the obtained regression coefficient (R2) was higher than 0.98 and the recoveries were higher than 60% for the majority of the assessed pollutants.
Collapse
Affiliation(s)
- Josephine Al-Alam
- Azm Center for Research in Biotechnology and its Applications, Doctoral School of Science and Technology, Lebanese University, El Mittein Street, Tripoli, Lebanon; Institute of Chemistry and Processes for Energy, Environment and Health ICPEES UMR 7515 Group of Physical Chemistry of the Atmosphere, University of Strasbourg, Strasbourg, France; Lebanese American University, School of Engineering, Byblos, Lebanon
| | - Firas Baroudi
- Institute of Chemistry and Processes for Energy, Environment and Health ICPEES UMR 7515 Group of Physical Chemistry of the Atmosphere, University of Strasbourg, Strasbourg, France
| | - Asma Chbani
- Azm Center for Research in Biotechnology and its Applications, Doctoral School of Science and Technology, Lebanese University, El Mittein Street, Tripoli, Lebanon; Faculty of Public Health III, Lebanese University, Tripoli, Lebanon
| | - Ziad Fajloun
- Azm Center for Research in Biotechnology and its Applications, Doctoral School of Science and Technology, Lebanese University, El Mittein Street, Tripoli, Lebanon; Department of Biology, Faculty of Sciences 3, Lebanese University, Michel Slayman Tripoli Campus, Ras Maska 1352, Lebanon
| | - Maurice Millet
- Institute of Chemistry and Processes for Energy, Environment and Health ICPEES UMR 7515 Group of Physical Chemistry of the Atmosphere, University of Strasbourg, Strasbourg, France.
| |
Collapse
|
12
|
One-step cold-induced aqueous two-phase system for the simultaneous determination of fipronil and its metabolites in dietary samples by liquid chromatography–high resolution mass spectrometry and the application in Total Diet Study. Food Chem 2020; 309:125748. [DOI: 10.1016/j.foodchem.2019.125748] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2019] [Revised: 09/17/2019] [Accepted: 10/19/2019] [Indexed: 01/07/2023]
|
13
|
Untargeted analysis of nanoLC-HRMS data by ANOVA-PCA to highlight metabolites in Gammarus fossarum after in vivo exposure to pharmaceuticals. Talanta 2019; 202:221-229. [PMID: 31171174 DOI: 10.1016/j.talanta.2019.04.028] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Revised: 04/05/2019] [Accepted: 04/10/2019] [Indexed: 12/22/2022]
Abstract
In Western Europe, river water quality can be assessed using sentinel species such as the amphipod Gammarus fossarum. In this work of environmental metabolomics, the objective was to develop suitable chemometrics methods, using a limited number of individuals, to assess the modification of the metabolism of G. fossarum exposed to two human pharmaceuticals. Males and females gammarids were exposed to a mixture of the anxiolytic oxazepam and the antiepileptic carbamazepine (1000 ng L-1) for 14 days under laboratory conditions according to a full factorial design 2² (repeated 5 times). They were analyzed at the single individual scale using a method including a μQuEChERS type extraction followed by a nanoliquid chromatography analysis coupled to high-resolution mass spectrometry. The molecular fingerprints obtained were investigated using XCMS. Several corrections of experimental drifts (by using lock mass and Quality Control samples) were tested prior to using APCA + method for the exploitation of the unbalanced designed data. Signal reproducibility was greatly improved by the lock mass normalisation. From the experimental design, a significant effect of both experimental factors "exposure to the mixture" and "gammarid gender" on the signals measured were highlighted by APCA+. Finally, the results obtained made it possible to identify variables responsible for each of the factor effects.
Collapse
|
14
|
Munz NA, Fu Q, Stamm C, Hollender J. Internal Concentrations in Gammarids Reveal Increased Risk of Organic Micropollutants in Wastewater-Impacted Streams. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2018; 52:10347-10358. [PMID: 30117321 DOI: 10.1021/acs.est.8b03632] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Internal concentrations link external exposure to the potential effect, as they reflect what the organisms actually take up and experience physiologically. In this study, we investigated whether frequently detected risk-driving substances in water were found in the exposed organisms and if they are classified the same based on the whole body internal concentrations. Field gammarids were collected upstream and downstream of ten wastewater treatment plants in mixed land use catchments. The sampling was conducted in autumn and winter, during low flow conditions when diffuse agricultural input was reduced. The field study was complemented with laboratory and flume experiments to determine the bioaccumulation potentials of selected substances. For 32 substances, apparent bioaccumulation factors in gammarids were determined for the first time. With a sensitive multiresidue method based on online-solid phase extraction followed by liquid chromatography coupled to high resolution mass spectrometry, we detected 63 (semi-) polar organic substances in the field gammarids, showing higher concentrations downstream than upstream. Interestingly, neonicotinoids, which are particularly toxic toward invertebrates, were frequently detected and were further determined as major contributors to the toxic pressure based on the toxic unit approach integrating internal concentration and toxic potency. The total toxic pressure based on internal concentrations was substantially higher compared to when external concentrations were used. Thus, internal concentrations may add more value to the current environmental risk assessment that is typically based solely on external exposure.
Collapse
Affiliation(s)
- Nicole A Munz
- Eawag , Swiss Federal Institute of Aquatic Science and Technology , 8600 Dübendorf , Switzerland
- Institute of Biogeochemistry and Pollutant Dynamics , ETH Zürich , 8092 Zürich , Switzerland
| | - Qiuguo Fu
- Eawag , Swiss Federal Institute of Aquatic Science and Technology , 8600 Dübendorf , Switzerland
| | - Christian Stamm
- Eawag , Swiss Federal Institute of Aquatic Science and Technology , 8600 Dübendorf , Switzerland
| | - Juliane Hollender
- Eawag , Swiss Federal Institute of Aquatic Science and Technology , 8600 Dübendorf , Switzerland
- Institute of Biogeochemistry and Pollutant Dynamics , ETH Zürich , 8092 Zürich , Switzerland
| |
Collapse
|
15
|
A review of nanoscale LC-ESI for metabolomics and its potential to enhance the metabolome coverage. Talanta 2018; 182:380-390. [PMID: 29501168 DOI: 10.1016/j.talanta.2018.01.084] [Citation(s) in RCA: 65] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Revised: 01/29/2018] [Accepted: 01/30/2018] [Indexed: 12/22/2022]
Abstract
Liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) platforms are widely used to perform high throughput untargeted profiling of biological samples for metabolomics-based approaches. However, these LC-ESI platforms usually favour the detection of metabolites present at relatively high concentrations because of analytical limitations such as ion suppression, thus reducing overall sensitivity. To counter this issue of sensitivity, the latest in terms of analytical platforms can be adopted to enable a greater portion of the metabolome to be analysed in a single analytical run. Here, nanoflow liquid chromatography-nanoelectrospray ionisation (nLC-nESI), which has previously been utilised successfully in proteomics, is explored for use in metabolomic and exposomic research. As a discovery based field, the markedly increased sensitivity of these nLC-nESI platforms offer the potential to uncover the roles played by low abundant signalling metabolites (e.g. steroids, eicosanoids) in health and disease studies, and would also enable an improvement in the detection of xenobiotics present at trace levels in biological matrices to better characterise the chemical exposome. This review aims to give an insight into the advantages associated with nLC-nESI for metabolomics-based approaches. Initially we detail the source of improved sensitivity prior to reviewing the available approaches to achieving nanoflow rates and nanospray ionisation for metabolomics. The robustness of nLC-nESI platforms was then assessed using the literature available from a metabolomic viewpoint. We also discuss the challenging point of sample preparation which needs to be addressed to fully enjoy the benefits of these nLC-nESI platforms. Finally, we assess metabolomic analysis utilising nano scale platforms and look ahead to the future of metabolomics using these new highly sensitive platforms.
Collapse
|
16
|
Núñez M, Borrull F, Pocurull E, Fontanals N. Sample treatment for the determination of emerging organic contaminants in aquatic organisms. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2017.09.007] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
17
|
Robert A, Schultz IR, Hucher N, Monsinjon T, Knigge T. Toxicokinetics, disposition and metabolism of fluoxetine in crabs. CHEMOSPHERE 2017; 186:958-967. [PMID: 28830067 DOI: 10.1016/j.chemosphere.2017.08.018] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2017] [Revised: 07/30/2017] [Accepted: 08/05/2017] [Indexed: 06/07/2023]
Abstract
The disposition and metabolism of fluoxetine in the European shore crab and the Dungeness crab were assessed. Crabs received intracardiac doses of either 0.13 μg/kg or 0.5 mg/kg fluoxetine, respectively. In addition, fluoxetine was administered to Metacarcinus cancer by oral gavage at 7.8 mg/kg. The distribution of fluoxetine was quantified in haemolymph and digestive gland for both crabs, as well as brain, muscle, and testis of Carcinus maenas, over 12 days. The metabolite norfluoxetine, was also measured in C. maenas. Fluoxetine was mainly found in lipid rich tissues. Distribution coefficients increased for digestive gland until three days after fluoxetine administration and then decreased until the end of the observations. The highest distribution coefficients were obtained for brain. Norfluoxetine displayed continuously high levels in digestive gland and brain. The strong decrease in fluoxetine and the concomitant increase in norfluoxetine demonstrates that decapod crustaceans metabolise fluoxetine into the more biologically active norfluoxetine. Fluoxetine levels in the haemolymph of M. cancer declined within 20 h, but showed a second peak 25 h later, suggesting remobilisation from tissues sequestering the compound. The steady state volume distribution and the total body clearance of fluoxetine were high, consistent with high diffusion of fluoxetine into the peripheral tissues and biotransformation as an important elimination pathway. Oral administration of fluoxetine prolonged its half-life in M. cancer, but bioavailability was low. These results confirm the high distribution into nervous tissue, extensive biotransformation into the highly active norfluoxetine and a half-life similar to that observed in vertebrates.
Collapse
Affiliation(s)
- Alexandrine Robert
- Normandy University, UMR-I 02 INERIS-URCA-ULH Environmental Stress and Aquatic Biomonitoring (SEBIO), FR CNRS 3730 SCALE, Université Le Havre Normandie, 25 Rue Philippe Lebon, F-76600, Le Havre, France
| | - Irvin R Schultz
- Pacific Northwest National Laboratory - Marine Sciences Laboratory, 1529 West Sequim Bay Road, Sequim, WA 98382, USA
| | - Nicolas Hucher
- Normandie Univ., UNILEHAVRE, FR 3038 CNRS, URCOM, F-76600, Le Havre, France
| | - Tiphaine Monsinjon
- Normandy University, UMR-I 02 INERIS-URCA-ULH Environmental Stress and Aquatic Biomonitoring (SEBIO), FR CNRS 3730 SCALE, Université Le Havre Normandie, 25 Rue Philippe Lebon, F-76600, Le Havre, France
| | - Thomas Knigge
- Normandy University, UMR-I 02 INERIS-URCA-ULH Environmental Stress and Aquatic Biomonitoring (SEBIO), FR CNRS 3730 SCALE, Université Le Havre Normandie, 25 Rue Philippe Lebon, F-76600, Le Havre, France.
| |
Collapse
|
18
|
Fanali S. An overview to nano-scale analytical techniques: Nano-liquid chromatography and capillary electrochromatography. Electrophoresis 2017; 38:1822-1829. [PMID: 28256745 DOI: 10.1002/elps.201600573] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2016] [Revised: 02/17/2017] [Accepted: 02/21/2017] [Indexed: 01/04/2023]
Abstract
Nano-liquid chromatography (nano-LC) and CEC are microfluidic techniques mainly used for analytical purposes. They have been applied to the separation and analysis of a large number of compounds, e.g., peptides, proteins, drugs, enantiomers, antibiotics, pesticides, nutraceutical, etc. Analytes separation is carried out into capillaries containing selected stationary phase. The mobile phase is moved either by a pump (nano-LC) or by an EOF, respectively. The two tools can offer some advantages over conventional techniques, e.g., high selectivity, separation efficiency, resolution, short analysis time and consumption of low volumes of mobile phase. Flow rates in the range 50-800 nL/min are usually applied. The low flow rate reduces the chromatographic dilution increasing the mass sensitivity. Special attention must be paid in avoiding peak dispersion selecting the appropriate detector, injector and tube connection. Finally due to the low flow rate these microfluidic techniques can be easily coupled with mass spectrometry.
Collapse
Affiliation(s)
- Salvatore Fanali
- Institute of Chemical Methodologies, Italian National Research Council, Monterotondo, Italy
| |
Collapse
|
19
|
Endocrine disrupting compounds (EDCs) in environmental matrices: Review of analytical strategies for pharmaceuticals, estrogenic hormones, and alkylphenol compounds. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.08.004] [Citation(s) in RCA: 93] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
20
|
Development of a multi-residue analysis of diclofenac and some transformation products in bivalves using QuEChERS extraction and liquid chromatography-tandem mass spectrometry. Application to samples from mesocosm studies. Talanta 2016; 155:1-7. [DOI: 10.1016/j.talanta.2016.04.016] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2016] [Revised: 04/04/2016] [Accepted: 04/05/2016] [Indexed: 12/16/2022]
|
21
|
Sordet M, Berlioz-Barbier A, Buleté A, Garric J, Vulliet E. Quantification of emerging micropollutants in an amphipod crustacean by nanoliquid chromatography coupled to mass spectrometry using multiple reaction monitoring cubed mode. J Chromatogr A 2016; 1456:217-25. [PMID: 27324621 DOI: 10.1016/j.chroma.2016.06.022] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2016] [Revised: 06/03/2016] [Accepted: 06/06/2016] [Indexed: 12/27/2022]
Abstract
An innovative analytical method has been developed to quantify the bioaccumulation in an amphipod crustacean (Gammarus fossarum) of three micropollutants regarded as anthropic-pollution markers: carbamazepine, oxazepam, and testosterone. A liquid-liquid extraction assisted by salts, known as QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) was miniaturised and optimised, so it could be adapted to the low mass samples (approximatively 5mg dry weight). For this same reason and in order to obtain good sensitivity, ultra-trace analyses were carried out by means of nanoliquid chromatography. A preconcentration system by on-column trapping was optimised to increase the injection volume. In order to improve both sensitivity and selectivity, the multiple reaction monitoring cubed mode analyses (MRM(3)) were carried out, validated and compared to the classic MRM. To the best of our knowledge, this is the first time that MRM(3) is coupled to nanoliquid chromatography for the analysis and detection of organic micropollutants <300Da. The optimised extraction method exhibited recoveries superior to 80%. The limits of quantification of the target compounds were 0.3, 0.7 and 4.7ng/g (wet weight) for oxazepam, carbamazepine and testosterone, respectively and the limits of detection were 0.1, 0.3 and 2.2ng/g (wet weight), respectively. The intra- and inter-day precisions were inferior to 7.7% and 10.9%, respectively, for the three levels of concentration tested. The analytical strategy developed allowed to obtain limits of quantification lower than 1ng/g (wet weight) and to establish the kinetic bioconcentration of contaminants within G. fossarum.
Collapse
Affiliation(s)
- Martin Sordet
- Université de Lyon, Institut des Sciences Analytiques, UMR5280, CNRS, Université Lyon 1, ENS-Lyon, 5 rue de la Doua, 69100 Villeurbanne, France
| | - Alexandra Berlioz-Barbier
- Université de Lyon, Institut des Sciences Analytiques, UMR5280, CNRS, Université Lyon 1, ENS-Lyon, 5 rue de la Doua, 69100 Villeurbanne, France
| | - Audrey Buleté
- Université de Lyon, Institut des Sciences Analytiques, UMR5280, CNRS, Université Lyon 1, ENS-Lyon, 5 rue de la Doua, 69100 Villeurbanne, France
| | - Jeanne Garric
- IRSTEA, UR MAEP, Laboratoire d'écotoxicologie, 5 rue de la Doua, 6100 Villeurbanne, France
| | - Emmanuelle Vulliet
- Université de Lyon, Institut des Sciences Analytiques, UMR5280, CNRS, Université Lyon 1, ENS-Lyon, 5 rue de la Doua, 69100 Villeurbanne, France.
| |
Collapse
|
22
|
Bussy U, Li K, Li W. Application of liquid chromatography-tandem mass spectrometry in quantitative bioanalyses of organic molecules in aquatic environment and organisms. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2016; 23:9459-79. [PMID: 26996906 DOI: 10.1007/s11356-016-6433-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2015] [Accepted: 03/07/2016] [Indexed: 05/16/2023]
Abstract
Analytical methods using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of metabolites or contaminants (or both) in various tissues of aquatic organisms and in the aquatic environment have received increasing attention in the last few years. This review discusses the findings relevant to such procedures published between 2005 and 2015. The aim is to evaluate the advantages, restrictions, and performances of the procedures from sample preparation to mass spectrometry measurement. To support these discussions, a general knowledge on LC-MS/MS is also provided.
Collapse
Affiliation(s)
- Ugo Bussy
- Department of Fisheries and Wildlife, Michigan State University, 480 Wilson Road, Room 13, Natural Resources Bldg., East Lansing, MI, 48824, USA
| | - Ke Li
- Department of Fisheries and Wildlife, Michigan State University, 480 Wilson Road, Room 13, Natural Resources Bldg., East Lansing, MI, 48824, USA
| | - Weiming Li
- Department of Fisheries and Wildlife, Michigan State University, 480 Wilson Road, Room 13, Natural Resources Bldg., East Lansing, MI, 48824, USA.
| |
Collapse
|
23
|
Daniele G, Fieu M, Joachim S, Bado-Nilles A, Baudoin P, Turies C, Porcher JM, Andres S, Vulliet E. Rapid analysis of diclofenac and some of its transformation products in the three-spined stickleback, Gasterosteus aculeatus, by liquid chromatography-tandem mass spectrometry. Anal Bioanal Chem 2016; 408:4435-44. [DOI: 10.1007/s00216-016-9541-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2016] [Revised: 03/18/2016] [Accepted: 04/04/2016] [Indexed: 12/12/2022]
|
24
|
Microvolume trace environmental analysis using peak-focusing online solid-phase extraction–nano-liquid chromatography–high-resolution mass spectrometry. Anal Bioanal Chem 2016; 408:1879-90. [DOI: 10.1007/s00216-015-9294-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2015] [Revised: 12/18/2015] [Accepted: 12/22/2015] [Indexed: 01/25/2023]
|
25
|
Cortéjade A, Kiss A, Cren C, Vulliet E, Buleté A. Development of an analytical method for the targeted screening and multi-residue quantification of environmental contaminants in urine by liquid chromatography coupled to high resolution mass spectrometry for evaluation of human exposures. Talanta 2015; 146:694-706. [PMID: 26695319 DOI: 10.1016/j.talanta.2015.06.038] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2015] [Revised: 06/09/2015] [Accepted: 06/15/2015] [Indexed: 01/17/2023]
Abstract
The aim of this study was to develop an analytical method and contribute to the assessment of the Exposome. Thus, a targeted analysis of a wide range of contaminants in contact with humans on daily routines in urine was developed. The method focused on a list of 38 contaminants, including 12 pesticides, one metabolite of pesticide, seven veterinary drugs, five parabens, one UV filter, one plastic additive, two surfactants and nine substances found in different products present in the everyday human environment. These contaminants were analyzed by high performance liquid chromatography coupled to high resolution mass spectrometry (HPLC-HRMS) with a quadrupole-time-of-flight (QqToF) instrument from a raw urinary matrix. A validation according to the FDA guidelines was employed to evaluate the specificity, linear or quadratic curve fitting, inter- and intra-day precision, accuracy and limits of detection and quantification (LOQ). The developed analysis allows for the quantification of 23 contaminants in the urine samples, with the LOQs ranging between 4.3 ng.mL(-1) and 113.2 ng.mL(-1). This method was applied to 17 urine samples. Among the targeted contaminants, four compounds were detected in samples. One of the contaminants (tributyl phosphate) was detected below the LOQ. The three others (4-hydroxybenzoic acid, sodium dodecylbenzenesulfonate and O,O-diethyl thiophosphate potassium) were detected but did not fulfill the validation criteria for quantification. Among these four compounds, two of them were found in all samples: tributyl phosphate and the surfactant sodium dodecylbenzenesulfonate.
Collapse
Affiliation(s)
- A Cortéjade
- Université de Lyon, Institut des Sciences Analytiques, UMR5280 CNRS, Université Lyon 1, ENS-Lyon, 5 rue de la Doua, 69100 Villeurbanne, France
| | - A Kiss
- Université de Lyon, Institut des Sciences Analytiques, UMR5280 CNRS, Université Lyon 1, ENS-Lyon, 5 rue de la Doua, 69100 Villeurbanne, France
| | - C Cren
- Université de Lyon, Institut des Sciences Analytiques, UMR5280 CNRS, Université Lyon 1, ENS-Lyon, 5 rue de la Doua, 69100 Villeurbanne, France
| | - E Vulliet
- Université de Lyon, Institut des Sciences Analytiques, UMR5280 CNRS, Université Lyon 1, ENS-Lyon, 5 rue de la Doua, 69100 Villeurbanne, France
| | - A Buleté
- Université de Lyon, Institut des Sciences Analytiques, UMR5280 CNRS, Université Lyon 1, ENS-Lyon, 5 rue de la Doua, 69100 Villeurbanne, France.
| |
Collapse
|
26
|
Determination of pharmaceuticals in bivalves using QuEChERS extraction and liquid chromatography-tandem mass spectrometry. Anal Bioanal Chem 2015; 407:3841-9. [DOI: 10.1007/s00216-015-8617-2] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2015] [Revised: 03/02/2015] [Accepted: 03/03/2015] [Indexed: 10/23/2022]
|