1
|
Rodiouchkina K, Rodushkin I, Goderis S, Vanhaecke F. A comprehensive evaluation of sulfur isotopic analysis (δ 34S and δ 33S) using multi-collector ICP-MS with characterization of reference materials of geological and biological origin. Anal Chim Acta 2023; 1240:340744. [PMID: 36641153 DOI: 10.1016/j.aca.2022.340744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 11/27/2022] [Accepted: 12/21/2022] [Indexed: 12/24/2022]
Abstract
Sulfur isotope ratios are often used as biogeochemical tracers to gain understanding of abiotic and biological processes involved in the sulfur cycle in both modern and ancient environments. There is however a lack of matrix-matched well-characterized isotopic reference materials that are essential for controlling the accuracy and precision. This study therefore focused on expanding and complementing the currently available sulfur isotope ratio data by providing the bulk sulfur isotopic composition, as determined using multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS), for a comprehensive set of commercially and/or readily available biological and geological reference materials. A total 7 isotopic reference materials and 41 elemental reference materials were studied. These reference materials include standards of terrestrial and marine animal origin, terrestrial plant origin, human origin, and geological origin. Different sample preparation protocols, including digestion and subsequent chromatographic isolation of S, were evaluated and the optimum approach selected for each matrix type. For achieving enhanced robustness, the sample preparation and sulfur isotope ratio measurements were done at two different laboratories for selected reference materials, while at one of the laboratories the measurements were additionally performed using two different MC-ICP-MS instruments. Determined δ34SVCDT and δ33SVCDT values compared well between the different laboratories, as well as between the different generation MC-ICP-MS instruments, and for standards that were previously characterized, our data are similar to literature values. The δ34SVCDT ranges determined for the different categories of the reference materials - terrestrial animal origin: +2 to +9‰, marine animal origin: +15 to +20‰, human origin: +6 to +10‰, terrestrial plant origin: -20 to +7‰, and geological origin: -12 to +21‰ - fit the expected values based on previous studies of similar types of matrices well. No significant mass-independent fractionation is observed when considering the expanded uncertainties for Δ33SV-CDT.
Collapse
Affiliation(s)
- Katerina Rodiouchkina
- Ghent University, Department of Chemistry, Atomic and Mass Spectrometry (A&MS) Research Group, Campus Sterre, Krijgslaan 281 - S12, 9000, Ghent, Belgium; Vrije Universiteit Brussel, Department of Chemistry; Analytical, Environmental and Geo-Chemistry (AMGC) Research Group, Pleinlaan 2, 1050, Brussels, Belgium
| | - Ilia Rodushkin
- ALS Scandinavia AB, ALS Laboratory Group, Aurorum 10, S-977 75, Luleå, Sweden
| | - Steven Goderis
- Vrije Universiteit Brussel, Department of Chemistry; Analytical, Environmental and Geo-Chemistry (AMGC) Research Group, Pleinlaan 2, 1050, Brussels, Belgium
| | - Frank Vanhaecke
- Ghent University, Department of Chemistry, Atomic and Mass Spectrometry (A&MS) Research Group, Campus Sterre, Krijgslaan 281 - S12, 9000, Ghent, Belgium.
| |
Collapse
|
2
|
Razionale D, Bryant RN, Blättler CL. Adapting automated instrumentation for high-throughput calcium isotope measurements by multi-collector inductively coupled plasma mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2022; 36:e9249. [PMID: 34957620 DOI: 10.1002/rcm.9249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 12/09/2021] [Accepted: 12/21/2021] [Indexed: 06/14/2023]
Abstract
RATIONALE Large, efficiently generated datasets of calcium isotope ratios offer tremendous utility in an increasing number of scientific disciplines. Modern analytical capabilities in mass spectrometry present unique challenges to previously established sample preparation techniques, the extent of which must be thoroughly examined before these data are interpreted and reported. This study addresses key methodological challenges in the determination of calcium isotopes using state-of-the-art, commercially available instruments. METHODS Automated ion chromatography was used to isolate calcium from carbonate- and seawater-like samples prior to analysis by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). A new, membrane-bearing desolvator (Apex-Ω) is implemented and achieves enhanced sensitivity, yet necessitates an update to established sample preparation techniques due to previously unobserved matrix effects. Performance of this method was assessed through analyses of multiple standard reference materials (SRM 915b, USGS EN-1, and seawater) and several in-house standards using a Neptune MC-ICP-MS instrument. RESULTS The enhanced sensitivity afforded by the Apex-Ω also yields pronounced matrix effects during mass spectrometry, resulting specifically from heightened sample Na and Sr content and deviations in sample [Ca] from their bracketing standards. While the latter can be addressed by a concentration correction, the first two matrix effects are mitigated using a modified chromatography technique that implements unique rinsing protocols. CONCLUSIONS This precise (0.14‰ 2σ), high-throughput method is very reproducible for small sample amounts and, at optimal efficiency, can generate approximately 140 sample δ44/40 Ca values per week with 5 h of in-person effort per day. Documented matrix effects are successfully mitigated through corrections and modified chromatographic techniques. Additionally, this method may be permuted to accommodate most major cations.
Collapse
Affiliation(s)
- Dan Razionale
- Department of the Geophysical Sciences, University of Chicago, Chicago, IL, USA
| | - Roger N Bryant
- Department of the Geophysical Sciences, University of Chicago, Chicago, IL, USA
| | - Clara L Blättler
- Department of the Geophysical Sciences, University of Chicago, Chicago, IL, USA
| |
Collapse
|
3
|
Martinez M, Garcia-Alonso JI, Parat C, Encinar JR, Hécho IL. Anion-Specific Sulfur Isotope Analysis by Liquid Chromatography Coupled to Multicollector ICPMS. Anal Chem 2019; 91:10088-10094. [PMID: 31295999 DOI: 10.1021/acs.analchem.9b02038] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
An accurate method has been developed to measure, in a single analytical run, δ34S in sulfite, sulfate and thiosulfate in water samples by liquid chromatography combined with multicollector inductively coupled plasma mass spectrometry (MC-ICPMS). The method is based on the anionic exchange separation of sulfur species prior to their online isotope ratio determination by MC-ICPMS. Mass bias correction was accomplished by a novel approach based on the addition of an internal sulfur-containing standard to the sample. This innovative approach was compared to the sample-standard bracketing procedure. On-column isotopic fractionation was observed and therefore corrected by external calibration. Isotopic ratios were calculated by linear regression slope (LRS), an advantageous method for transient signals, leading to a combined uncertainty of δ34S below 0.25‰ and a reproducibility below 0.5‰ for the injection of 1 μg of S. The method was successfully applied to the measurement of δ34S in synthetic solutions and environmental water samples. Matrix effects leading to δ34S overestimation were observed for sulfate in some samples with high sodium/sulfate mass ratios. The developed analytical procedure simplifies the δ34S analysis of liquid environmental samples since preparation steps are no longer required and allows the analysis of several sulfur-containing species in a single run.
Collapse
Affiliation(s)
- Mathieu Martinez
- CNRS/UNIV PAU & PAYS ADOUR/E2S UPPA , Institut des Sciences Analytiques et de Physico-Chimie pour l'Environnement et les Matériaux , UMR5254 , 64000 Pau , France
| | - Jose Ignacio Garcia-Alonso
- Department of Physical and Analytical Chemistry , University of Oviedo , Julián Clavería 8 , 33006 , Oviedo , Spain
| | - Corinne Parat
- CNRS/UNIV PAU & PAYS ADOUR/E2S UPPA , Institut des Sciences Analytiques et de Physico-Chimie pour l'Environnement et les Matériaux , UMR5254 , 64000 Pau , France
| | - Jorge Ruiz Encinar
- Department of Physical and Analytical Chemistry , University of Oviedo , Julián Clavería 8 , 33006 , Oviedo , Spain
| | - Isabelle Le Hécho
- CNRS/UNIV PAU & PAYS ADOUR/E2S UPPA , Institut des Sciences Analytiques et de Physico-Chimie pour l'Environnement et les Matériaux , UMR5254 , 64000 Pau , France
| |
Collapse
|
4
|
Yang LW, Liu C, Yang T. An evaluation on the extraction capability of anion exchange membranes for high-precision sulfur isotope measurement by multiple-collector inductively coupled plasma mass spectrometry. RSC Adv 2019; 9:31224-31232. [PMID: 35527964 PMCID: PMC9072498 DOI: 10.1039/c9ra04121d] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Accepted: 09/23/2019] [Indexed: 11/21/2022] Open
Abstract
Anion exchange membranes (AEMs) are adept at extracting sulfate for sulfur isotope analyses by multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) from natural samples typically with low sulfate concentrations.
Collapse
Affiliation(s)
- Liu Willow Yang
- State Key Laboratory for Mineral Deposits Research
- School of Earth Sciences and Engineering
- Nanjing University
- Nanjing 210093
- P. R. China
| | - Chenhui Liu
- State Key Laboratory for Mineral Deposits Research
- School of Earth Sciences and Engineering
- Nanjing University
- Nanjing 210093
- P. R. China
| | - Tao Yang
- State Key Laboratory for Mineral Deposits Research
- School of Earth Sciences and Engineering
- Nanjing University
- Nanjing 210093
- P. R. China
| |
Collapse
|
5
|
Hanousek O, Brunner M, Pröfrock D, Irrgeher J, Prohaska T. The performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/ 32S isotope ratio measurements. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2016; 8:7661-7672. [PMID: 27812369 PMCID: PMC5087850 DOI: 10.1039/c6ay02177h] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The performance and validation characteristics of different single collector inductively coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP-QMS in reaction and collision modes, and ICP-MS/MS) were evaluated in comparison to the performance of MC ICP-MS for fast and reliable S isotope ratio measurements. The validation included the determination of LOD, BEC, measurement repeatability, within-lab reproducibility and deviation from certified values as well as a study on instrumental isotopic fractionation (IIF) and the calculation of the combined standard measurement uncertainty. Different approaches of correction for IIF applying external intra-elemental IIF correction (aka standard-sample bracketing) using certified S reference materials and internal inter-elemental IIF (aka internal standardization) correction using Si isotope ratios in MC ICP-MS are explained and compared. The resulting combined standard uncertainties of examined ICP-QMS systems were not better than 0.3-0.5% (uc,rel), which is in general insufficient to differentiate natural S isotope variations. Although the performance of the single collector ICP-SFMS is better (single measurement uc,rel = 0.08%), the measurement reproducibility (>0.2%) is the major limit of this system and leaves room for improvement. MC ICP-MS operated in the edge mass resolution mode, applying bracketing for correction of IIF, provided isotope ratio values with the highest quality (relative combined measurement uncertainty: 0.02%; deviation from the certified value: <0.002%).
Collapse
Affiliation(s)
- Ondrej Hanousek
- University of Natural Resources and Life Sciences, Vienna, Department of Chemistry, VIRIS Laboratory, Konrad-Lorenz-Straße 24, 3430 Tulln, Austria
- University of Natural Resources and Life Sciences, Vienna, Department of Forest- and Soil Sciences, Institute of Forest Ecology, Peter-Jordan-Straße 82, 1190 Vienna, Austria
| | - Marion Brunner
- University of Natural Resources and Life Sciences, Vienna, Department of Chemistry, VIRIS Laboratory, Konrad-Lorenz-Straße 24, 3430 Tulln, Austria
| | - Daniel Pröfrock
- Department of Marine Bioanalytical Chemistry, Institute of Coastal Research, Helmholtz-Centre for Materials and Coastal Research, Max-Planck-Straße 1, 21502 Geesthacht, Germany
| | - Johanna Irrgeher
- Department of Marine Bioanalytical Chemistry, Institute of Coastal Research, Helmholtz-Centre for Materials and Coastal Research, Max-Planck-Straße 1, 21502 Geesthacht, Germany
| | - Thomas Prohaska
- University of Natural Resources and Life Sciences, Vienna, Department of Chemistry, VIRIS Laboratory, Konrad-Lorenz-Straße 24, 3430 Tulln, Austria
| |
Collapse
|
6
|
Mapping of Sulfur Isotopes and Trace Elements in Sulfides by LA-(MC)-ICP-MS: Potential Analytical Problems, Improvements and Implications. MINERALS 2016. [DOI: 10.3390/min6040110] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
7
|
Zheng J, Cao L, Tagami K, Uchida S. Triple-Quadrupole Inductively Coupled Plasma-Mass Spectrometry with a High-Efficiency Sample Introduction System for Ultratrace Determination of 135Cs and 137Cs in Environmental Samples at Femtogram Levels. Anal Chem 2016; 88:8772-9. [DOI: 10.1021/acs.analchem.6b02150] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Jian Zheng
- Biospheric Assessment for Waste Disposal Team & Fukushima Project Headquarters, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology Anagawa 4-9-1, Inage, Chiba 263-8555, Japan
| | - Liguo Cao
- Biospheric Assessment for Waste Disposal Team & Fukushima Project Headquarters, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology Anagawa 4-9-1, Inage, Chiba 263-8555, Japan
- School
of Geographic and Oceanographic Sciences, Nanjing University, Nanjing 210023, China
| | - Keiko Tagami
- Biospheric Assessment for Waste Disposal Team & Fukushima Project Headquarters, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology Anagawa 4-9-1, Inage, Chiba 263-8555, Japan
| | - Shigeo Uchida
- Biospheric Assessment for Waste Disposal Team & Fukushima Project Headquarters, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology Anagawa 4-9-1, Inage, Chiba 263-8555, Japan
| |
Collapse
|