1
|
Qu G, Liu G, Zhao C, Yuan Z, Yang Y, Xiang K. Detection and treatment of mono and polycyclic aromatic hydrocarbon pollutants in aqueous environments based on electrochemical technology: recent advances. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2024; 31:23334-23362. [PMID: 38436845 DOI: 10.1007/s11356-024-32640-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 02/21/2024] [Indexed: 03/05/2024]
Abstract
Mono and polycyclic aromatic hydrocarbons are widely distributed and severely pollute the aqueous environment due to natural and human activities, particularly human activity. It is crucial to identify and address them in order to reduce the dangers and threats they pose to biological processes and ecosystems. In the fields of sensor detection and water treatment, electrochemistry plays a crucial role as a trustworthy and environmentally friendly technology. In order to accomplish trace detection while enhancing detection accuracy and precision, researchers have created and studied sensors using a range of materials based on electrochemical processes, and their results have demonstrated good performance. One cannot overlook the challenges associated with treating aromatic pollutants, including mono and polycyclic. Much work has been done and good progress has been achieved in order to address these challenges. This study discusses the mono and polycyclic aromatic hydrocarbon sensor detection and electrochemical treatment technologies for contaminants in the aqueous environment. Additionally mentioned are the sources, distribution, risks, hazards, and problems in the removal of pollutants. The obstacles to be overcome and the future development plans of the field are then suggested by summarizing and assessing the research findings of the researchers.
Collapse
Affiliation(s)
- Guangfei Qu
- Faculty of Environmental Science and Engineering, Kunming University of Science & Technology, Kunming, 650500, Yunnan, China.
| | - Guojun Liu
- Faculty of Environmental Science and Engineering, Kunming University of Science & Technology, Kunming, 650500, Yunnan, China
| | - Chenyang Zhao
- Faculty of Environmental Science and Engineering, Kunming University of Science & Technology, Kunming, 650500, Yunnan, China
| | - Zheng Yuan
- Faculty of Environmental Science and Engineering, Kunming University of Science & Technology, Kunming, 650500, Yunnan, China
| | - Yixin Yang
- Faculty of Environmental Science and Engineering, Kunming University of Science & Technology, Kunming, 650500, Yunnan, China
| | - Keyi Xiang
- Faculty of Environmental Science and Engineering, Kunming University of Science & Technology, Kunming, 650500, Yunnan, China
| |
Collapse
|
2
|
Huang Z, Chen Z, Yan D, Jiang S, Nie L, Tu X, Jia X, Wågberg T, Chao L. Preparation of Gold Nanoparticles via Anodic Stripping of Copper Underpotential Deposition in Bulk Gold Electrodeposition for High-Performance Electrochemical Sensing of Bisphenol A. Molecules 2023; 28:8036. [PMID: 38138526 PMCID: PMC10745752 DOI: 10.3390/molecules28248036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Revised: 11/26/2023] [Accepted: 11/28/2023] [Indexed: 12/24/2023] Open
Abstract
Bisphenol A is one of the most widely used industrial compounds. Over the years, it has raised severe concern as a potential hazard to the human endocrine system and the environment. Developing robust and easy-to-use sensors for bisphenol A is important in various areas, such as controlling and monitoring water purification and sewage water systems, food safety monitoring, etc. Here, we report an electrochemical method to fabricate a bisphenol A (BPA) sensor based on a modified Au nanoparticles/multiwalled carbon nanotubes composite electrocatalyst electrode (AuCu-UPD/MWCNTs/GCE). Firstly, the Au-Cu alloy was prepared via a convenient and controllable Cu underpotential/bulk Au co-electrodeposition on a multiwalled modified carbon nanotubes glassy carbon electrode (GCE). Then, the AuCu-UPD/MWCNTs/GCE was obtained via the electrochemical anodic stripping of Cu underpotential deposition (UPD). Our novel prepared sensor enables the high-electrocatalytic and high-performance sensing of BPA. Under optimal conditions, the modified electrode showed a two-segment linear response from 0.01 to 1 µM and 1 to 20 µM with a limit of detection (LOD) of 2.43 nM based on differential pulse voltammetry (DPV). Determination of BPA in real water samples using AuCu-UPD/MWCNTs/GCE yielded satisfactory results. The proposed electrochemical sensor is promising for the development of a simple, low-cost water quality monitoring system for the detection of BPA in ambient water samples.
Collapse
Affiliation(s)
- Zhao Huang
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, College of Life Sciences and Chemistry, Hunan University of Technology, Zhuzhou 412007, China; (Z.H.); (Z.C.); (D.Y.); (S.J.); (L.N.); (X.J.)
| | - Zihan Chen
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, College of Life Sciences and Chemistry, Hunan University of Technology, Zhuzhou 412007, China; (Z.H.); (Z.C.); (D.Y.); (S.J.); (L.N.); (X.J.)
| | - Dexuan Yan
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, College of Life Sciences and Chemistry, Hunan University of Technology, Zhuzhou 412007, China; (Z.H.); (Z.C.); (D.Y.); (S.J.); (L.N.); (X.J.)
| | - Shuo Jiang
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, College of Life Sciences and Chemistry, Hunan University of Technology, Zhuzhou 412007, China; (Z.H.); (Z.C.); (D.Y.); (S.J.); (L.N.); (X.J.)
| | - Libo Nie
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, College of Life Sciences and Chemistry, Hunan University of Technology, Zhuzhou 412007, China; (Z.H.); (Z.C.); (D.Y.); (S.J.); (L.N.); (X.J.)
| | - Xinman Tu
- Key Laboratory of Jiangxi Province for Persistent Pollutants Control and Resources Recycle, Nanchang Hangkong University, Nanchang 330063, China;
| | - Xueen Jia
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, College of Life Sciences and Chemistry, Hunan University of Technology, Zhuzhou 412007, China; (Z.H.); (Z.C.); (D.Y.); (S.J.); (L.N.); (X.J.)
- Department of Physics, Umeå University, SE-901 87 Umeå, Sweden;
| | - Thomas Wågberg
- Department of Physics, Umeå University, SE-901 87 Umeå, Sweden;
| | - Long Chao
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, College of Life Sciences and Chemistry, Hunan University of Technology, Zhuzhou 412007, China; (Z.H.); (Z.C.); (D.Y.); (S.J.); (L.N.); (X.J.)
| |
Collapse
|
3
|
Silva HRD, Barbosa KM, Alsaiari RA, Silva GN, Junior JLOM, Cangussu ASR, Barros SBA, Costa LSD, dos Santos Junior JR, De Moura CVR, Alsaiari M, de Oliveira VV, Pereira AKDS, Santos LSS, Rahim A. Gold Nanoparticle-Loaded Silica Nanospheres for Sensitive and Selective Electrochemical Detection of Bisphenol A. ACS OMEGA 2023; 8:39023-39034. [PMID: 37901482 PMCID: PMC10600914 DOI: 10.1021/acsomega.3c03607] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Accepted: 09/15/2023] [Indexed: 10/31/2023]
Abstract
In this work, silica nanospheres were used as support for gold nanoparticles and applied for bisphenol A electrochemical detection. The development of new silica-supported materials has attracted increasing attention in the scientific world. One approach of interest is using silica nanospheres as support for gold nanoparticles. These materials have a variety of applications in several areas, such as electrochemical sensors. The obtained materials were characterized by solid-state UV-vis spectroscopy, electron microscopy, X-ray diffraction, and electrochemical techniques. The electrode modified with AuSiO2700/CHI/Pt was applied as an electrochemical sensor for BPA, presenting an oxidation potential of 0.842 V and a higher peak current among the tested materials. The AuSiO2700/CHI/Pt electrode showed a logarithmic response for the detection of BPA in the range of 1-1000 nmol L-1, with a calculated detection limit of 7.75 nmol L-1 and a quantification limit of 25.8 nmol L-1. Thus, the electrode AuSiO2700/CHI/Pt was presented as a promising alternative to an electrochemical sensor in the detection of BPA.
Collapse
Affiliation(s)
| | - Keleen M. Barbosa
- Universidade
Federal do Tocantins, Campus de Gurupi, Gurupi 77001-090, Tocantins, Brazil
| | - Raiedhah A. Alsaiari
- Department
of Chemistry, Faculty of Science and Arts at Sharurah, Najran University, Sharurah 68342, Saudi Arabia
| | - Gabriela Nunes Silva
- Universidade
Federal do Tocantins, Campus de Gurupi, Gurupi 77001-090, Tocantins, Brazil
| | | | | | | | - Luelc S. da Costa
- National
Nanotechnology Laboratory (LNNano), National Center for Research in
Energy and Materials (CNPEM), Campinas CEP: 13083-970, São
Paulo, Brazil
| | | | | | - Mabkhoot Alsaiari
- Department
of Chemistry, Faculty of Science and Arts at Sharurah, Najran University, Sharurah 68342, Saudi Arabia
| | | | - Anna K. dos S. Pereira
- Universidade
Federal do Tocantins, Campus de Gurupi, Gurupi 77001-090, Tocantins, Brazil
| | - Lucas Samuel S. Santos
- Universidade
Federal do Tocantins, Campus de Gurupi, Gurupi 77001-090, Tocantins, Brazil
| | - Abdur Rahim
- Department
of Chemistry, COMSATS University Islamabad, Park Road, Tarlai Kalan, Islamabad 45550, Pakistan
| |
Collapse
|
4
|
Silva TA, Lourencao BC, Dias da Silva A, Fatibello-Filho O. An electrochemical sensing platform based on carbon black and chitosan-stabilized platinum nanoparticles. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:1077-1086. [PMID: 36752550 DOI: 10.1039/d2ay01964g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
The versatility of chitosan (Ch) biopolymer as a metallic nanoparticle stabilizing agent and excellent former of thin films on glassy carbon was explored in this work for the sustainable manufacture of novel electrochemical sensors based on carbon black (CB) and chitosan-stabilized platinum nanoparticles (Ch-PtNPs). Platinum nanoparticles highly stabilized by chitosan were easily synthesized at room temperature and characterized by HR-TEM, UV-vis, and voltammetry. Ch-PtNPs presented an average diameter of 2.7 nm, and typical voltammetric peaks of Pt in sulfuric acid medium were detected for films containing Ch-PtNPs. As a proof of concept, the CB-Ch-PtNP electrode was applied in the determination of hydrogen peroxide (H2O2) and the endocrine disruptor bisphenol A (BPA). Pronounced electrocatalytic activity towards H2O2 reduction was observed in the presence of Ch-PtNPs in the films, guaranteeing the non-enzymatic determination of H2O2 by chronoamperometry, with a limit of detection of 10 μmol L-1. In the determination of BPA by differential pulse adsorptive anodic stripping voltammetry (DPAdASV), under optimal experimental conditions, a wide linear response range and a limit of detection at the nanomolar level (7.9 nmol L-1) were achieved. In addition, excellent repeatabilities of sensor response and sensor fabrication, and accuracy in the analysis of natural water samples were obtained.
Collapse
Affiliation(s)
- Tiago Almeida Silva
- Department of Chemistry, Federal University of São Carlos, 13560-970, São Carlos, SP, Brazil.
- Department of Chemistry, Federal University of Viçosa, 36570-900, Viçosa, MG, Brazil
| | - Bruna Claudia Lourencao
- Department of Chemistry, Federal University of São Carlos, 13560-970, São Carlos, SP, Brazil.
- Minas Gerais State University, 38302-192, Ituiutaba, MG, Brazil
| | | | - Orlando Fatibello-Filho
- Department of Chemistry, Federal University of São Carlos, 13560-970, São Carlos, SP, Brazil.
| |
Collapse
|
5
|
Sunil Kumar Naik TS, Singh S, N P, Varshney R, Uppara B, Singh J, Khan NA, Singh L, Zulqarnain Arshad M, C Ramamurthy P. Advanced experimental techniques for the sensitive detection of a toxic bisphenol A using UiO-66-NDC/GO-based electrochemical sensor. CHEMOSPHERE 2023; 311:137104. [PMID: 36347345 DOI: 10.1016/j.chemosphere.2022.137104] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Revised: 10/18/2022] [Accepted: 10/30/2022] [Indexed: 06/16/2023]
Abstract
In the present study, a simple and sensitive method for detecting bisphenol A (BPA) in various environments, including groundwater, was described using a widespread electrochemical method. BPA is well-known for its endocrine-disrupting properties, which may cause potential toxicological effects oon the nervous, reproductive, and immune systems. A novel metal-organic framework (UiO-66-NDC/GO) was synthesized, and its existence was confirmed by several characterization techniques like FTIR, UV-visible, XRD, SEM-EDX, Raman spectroscopy, and TGA. Due to the excellent electrocatalytic nature, UiO-66-NDC/GO was chosen as the sensor material and integrated on the surface of the bare carbon paste electrode (BCPE). The UiO-66-NDC/GO modified carbon paste electrode (MCPE) was engaged for the detection of BPA using techniques like cyclic Voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). The applied sensor exhibited an astonishing outcome for BPA detection with high sensitivity and selectivity. The lower detection limit (LLOD) of 0.025 μM was achieved at the modified sensor with a linear concentration range of 10-70 μM. Moreover, the practical applicability of the sensor was tested on tap water, drinking water, and fresh liquid milk, giving an excellent recovery of BPA in the range of 94.8-99.3 (v.%). The proposed method could be employed for electrochemical device or a solid state device fabrication for the onsite monitoring of BPA.
Collapse
Affiliation(s)
- T S Sunil Kumar Naik
- Department of Materials Engineering, Indian Institute of Science, Bangalore, 560012, India
| | - Simranjeet Singh
- Interdisciplinary Centre for Water Research (ICWaR), Indian Institute of Science, Bangalore, 560012, India
| | - Pavithra N
- Interdisciplinary Centre for Water Research (ICWaR), Indian Institute of Science, Bangalore, 560012, India
| | - Radhika Varshney
- Interdisciplinary Centre for Water Research (ICWaR), Indian Institute of Science, Bangalore, 560012, India
| | - Basavaraju Uppara
- Department of Materials Engineering, Indian Institute of Science, Bangalore, 560012, India
| | - Joginder Singh
- Department of Microbiology, Lovely Professional University, Jalandhar, Punjab, 144111, India
| | - Nadeem A Khan
- Department of Civil Engineering , Mewat Engineering College, Nuh, Haryana, 122107, India
| | - Lakhveer Singh
- Department of Chemistry, Sardar Patel University, Mandi, Himachal Pradesh, 175001, India
| | | | - Praveen C Ramamurthy
- Department of Materials Engineering, Indian Institute of Science, Bangalore, 560012, India; Interdisciplinary Centre for Water Research (ICWaR), Indian Institute of Science, Bangalore, 560012, India.
| |
Collapse
|
6
|
Xu CY, Ning KP, Wang Z, Yao Y, Xu Q, Hu XY. Flexible Electrochemical Platform Coupled with In Situ Prepared Synthetic Receptors for Sensitive Detection of Bisphenol A. BIOSENSORS 2022; 12:1076. [PMID: 36551043 PMCID: PMC9775942 DOI: 10.3390/bios12121076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Revised: 11/15/2022] [Accepted: 11/21/2022] [Indexed: 06/17/2023]
Abstract
A flexible electrochemical sensor based on the carbon felt (CF) functionalized with Bisphenol A (BPA) synthetic receptors was developed. The artificial Bisphenol A receptors were grafted on the CF by a simple thermal polymerization molecular imprinting process. Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and electrochemical characterizations were used to analyze the receptors. Characterization results demonstrated that the Bisphenol A synthetic receptors successfully formed on the CFs surface. Because the synthetic receptor and the porous CFs were successfully combined, the sensor displayed a better current response once Bisphenol A was identified. The sensor's linear range was determined to be from 0.5 to 8.0 nM and 10.0 to 300.0 nM, with a detection limit of 0.36 nM. Even after being bent and stretched repeatedly, the electrode's performance was unaffected, demonstrating the robustness, adaptability and viability of installing the sensor on flat or curved surfaces for on-site detection. The designed electrochemical sensor has been used successfully to identify Bisphenol A in milk samples with satisfactory results. This work provided a promising platform for the design of implantable, portable and miniaturized sensors.
Collapse
|
7
|
Acharya PB, George A, Shrivastav PS. A Status Update on the Development of Polymer and Metal-Based Graphene Electrochemical Sensors for Detection and Quantitation of Bisphenol A. Crit Rev Anal Chem 2022; 54:669-690. [PMID: 35776701 DOI: 10.1080/10408347.2022.2094197] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
The detection and quantitation of bisphenol A (BPA) in the environment and food products has been a subject of considerable interest. BPA, a diphenylmethane derivative is a well-known industrial raw material with wide range of applications. It is a well-known endocrine disruptor and acts as an estrogen mimic. BPA is an environmental health concern and its accumulation in hydro-geological cycles is a matter of serious ecological peril. This review basically assesses various chemically modified electrodes composed of diverse components that have been employed to recognize BPA in different matrices. Electrochemical sensors prepared using graphene materials in combination with metals and polymers for selective detection of BPA have been discussed extensively. The emphasis is on detection of BPA in various samples encountered in routine use such as plastic bottles, receipts, baby feed bottles, milk samples, mineralized water, tissue paper, DVDs, and others. Although research in this field is in the exploratory stage, deeper insights into fundamental studies of sensing systems, fast analysis of real samples and validation of sensors are some of the factors that need major impetus. It is expected that chemically modified electrode-based sensing systems will soon take over as a viable option for monitoring diverse pollutants.
Collapse
Affiliation(s)
- Prachi B Acharya
- Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad, Gujarat, India
| | - Archana George
- Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad, Gujarat, India
| | - Pranav S Shrivastav
- Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad, Gujarat, India
| |
Collapse
|
8
|
Chitosan/Gold Nanoparticles Nanocomposite Film for Bisphenol A Electrochemical Sensing. ELECTROCHEM 2022. [DOI: 10.3390/electrochem3020016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Bisphenol A (BPA) is considered an endocrine-disrupting compound and can cause toxicological effects, even at low doses. The development of sensitive and reliable sensors that would allow the detection of such contaminant is highly pursued. Herein, we report an electrochemical sensing strategy based on a simple and low-cost nanocomposite film sensor platform for BPA detection. The platform was developed by modifying a fluorine-doped tin oxide (FTO) electrode with layer-by-layer (LbL) films of chitosan (Chi) and gold nanoparticles functionalized with a polythiophene derivative (AuNPs:PTS). The growth of the Chi/AuNPs:PTS LbL films was monitored by UV–Vis spectroscopy. Electrochemical characterization revealed that the three-bilayer film exhibited the highest electrocatalytic performance and differential-pulse voltammetry (DPV) measurements demonstrated that the modified electrode was suitable for BPA detection through a quasi-reversible and adsorption-controlled electrochemical oxidation and reduction process. The developed sensor exhibited a linear response range from 0.4 to 20 μmol L−1, with a detection limit of 0.32 μmol L−1. The sensor showed good reproducibility with relative standard deviations of 2.12% and 3.73% to intra- and inter-electrode, respectively. Furthermore, the platform demonstrated to be suitable to detect BPA in real water samples, as well as selective for BPA detection in solutions with 100-fold excess of common interfering compounds.
Collapse
|
9
|
Moradi O. Electrochemical sensors based on carbon nanostructures for the analysis of bisphenol A-A review. Food Chem Toxicol 2022; 165:113074. [PMID: 35489466 DOI: 10.1016/j.fct.2022.113074] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Revised: 04/15/2022] [Accepted: 04/22/2022] [Indexed: 12/11/2022]
Abstract
Overuse of Bisphenol A (BPA), a proven endocrine disruptor, has become a serious public health problem across the world. It has the potential to harm both the environment and human health, notably reproductive disorders, heart disease, and diabetes. Accordingly, much attention has been paid to the detection of BPA to promote food safety and environmental health. Carbon based nanostructures have proven themselves well in a variety of applications, such as energy storage, catalysis and sensors, due to their remarkable properties. Therefore, researchers have recently focused on fabricating electrochemical BPA sensors based on carbon nanostructures due to their unique advantages, such as real-time monitoring, simplicity, high selectivity, high sensitivity and easy operation. The purpose of the current review was to summarize the recent findings on carbon nanostructures for electrochemically sensing the BPA, as well as relevant future prospects and ongoing challenges.
Collapse
Affiliation(s)
- Omid Moradi
- Department of Chemistry, Shahr-e-Qods Branch, Islamic Azad University, Tehran, Iran.
| |
Collapse
|
10
|
Label-free photoelectrochemical sensor based on 2D/2D ZnIn2S4/g-C3N4 heterojunction for the efficient and sensitive detection of bisphenol A. CHINESE CHEM LETT 2022. [DOI: 10.1016/j.cclet.2021.07.047] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
11
|
Engineering the doping amount of rare earth element erbium in CdWO4: Influence on the electrochemical performance and the application to the electrochemical detection of bisphenol A. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2021.115867] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
12
|
Recent advances in carbon nanomaterials-based electrochemical sensors for phenolic compounds detection. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106776] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
13
|
Jemmeli D, Dridi C, Abbas MN, Dempsey E. Development of highly sensitive and selective bisphenol A sensor based on a cobalt phthalocyanine-modified carbon paste electrode: application in dairy analysis. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:4674-4682. [PMID: 34549730 DOI: 10.1039/d1ay00827g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The development of an accurate, sensitive and selective sensor for the detection of bisphenol A (BPA) based on the incorporation of a new phthalocyanine derivative, cobalt phthalocyanine, C,C,C,C-tetracarboxylic acid-polyacrylamide (CoPc-PAA) into a carbon-paste matrix is presented using voltammetry and constant potential techniques. The influence of measuring parameters such as pH and scan rate on the analytical performance of the sensor was evaluated. Several kinetic parameters such as electron transfer number (n), charge transfer coefficient (α), electrode surface area (A) and diffusion coefficient (D) were also calculated. Under optimum conditions, particularly at pH 7.2, the BPA sensor resulted in a wide linear range from 25 × 10-11 M to 2.5 × 10-7 M and a limit of detection as low as 63.5 pM. Based on these findings, it can be concluded that our sensor can be substantially utilized for detecting BPA in spiked milk samples.
Collapse
Affiliation(s)
- Dhouha Jemmeli
- NANOMISENE Laboratory LR16CRMN01, Center of Research on Microelectronics and Nanotechnology (CRMN), Sousse Technopole, Tunisia.
| | - Chérif Dridi
- NANOMISENE Laboratory LR16CRMN01, Center of Research on Microelectronics and Nanotechnology (CRMN), Sousse Technopole, Tunisia.
| | - Mohammed N Abbas
- Analytical Laboratory, Department of Applied Organic Chemistry Polymer and Pigments Department, National Research Centre, Cairo, Egypt
| | - Eithne Dempsey
- Kathleen Lonsdale Institute for Human Health Research, Department of Chemistry, Maynooth University, Maynooth, Co. Kildare, Ireland
| |
Collapse
|
14
|
A comparison study of MFe2O4 (M: Ni, Cu, Zn)-reduced graphene oxide nanocomposite for electrochemical detection of bisphenol A. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.138519] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
15
|
Highly sensitive molecular imprinted voltammetric sensor for resveratrol assay in wine via polyaniline/gold nanoparticles signal enhancement and polyacrylamide recognition. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115455] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
16
|
Tsekeli T, Sebokolodi TI, Karimi-Maleh H, Arotiba OA. A Silver-Loaded Exfoliated Graphite Nanocomposite Anti-Fouling Electrochemical Sensor for Bisphenol A in Thermal Paper Samples. ACS OMEGA 2021; 6:9401-9409. [PMID: 33869920 PMCID: PMC8047760 DOI: 10.1021/acsomega.0c05836] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Accepted: 02/22/2021] [Indexed: 05/24/2023]
Abstract
Silver nanoparticles (AgNPs) were synthesized separately and loaded onto the expanded layers of exfoliated graphite (EG) to form a silver nanoparticle-exfoliated graphite nanocomposite (AgNPs-EG). The AgNPs-EG was compressed into a pellet (0.6 cm in diameter) and used to prepare an electrochemical sensor for bisphenol A (BPA) in standard samples and in thermal paper. The synthesized materials were characterized by ultraviolet-visible spectrophotometry, X-ray diffraction spectroscopy, scanning electron microscopy, and energy-dispersive X-ray. The electrochemical behavior of BPA on the AgNPs-EG sensor was investigated by cyclic voltammetry and square wave voltammetry. Under optimized experimental conditions, the oxidation peak current was linearly proportional to bisphenol A concentrations in the range from 5.0 to100 μM, with a coefficient of determination (R2 ) of 0.9981. The obtained limit of detection of the method was 0.23 μM. The fabricated sensor was able to overcome electrode fouling with good reproducibility (RSD = 2.62%, n = 5) by mechanical polishing of the electrode on emery paper. The proposed method was successfully applied to determine bisphenol A in thermal paper samples and demonstrated good accuracy of 93.1 to 113% recovery.
Collapse
Affiliation(s)
- Tebogo
R. Tsekeli
- Department
of Chemical Sciences, University of Johannesburg, Doornfontein, Johannesburg 2028, South Africa
| | - Tsholofelo I. Sebokolodi
- Department
of Chemical Sciences, University of Johannesburg, Doornfontein, Johannesburg 2028, South Africa
| | - Hassan Karimi-Maleh
- Department
of Chemical Sciences, University of Johannesburg, Doornfontein, Johannesburg 2028, South Africa
- University
of Electronic Science and Technology of China, Chengdu 611731, China
| | - Omotayo A. Arotiba
- Department
of Chemical Sciences, University of Johannesburg, Doornfontein, Johannesburg 2028, South Africa
- Centre
for Nanomaterials Science Research, University
of Johannesburg, Johannesburg 2028, South Africa
| |
Collapse
|
17
|
Eftekhari A, Dalili M, Karimi Z, Rouhani S, Hasanzadeh A, Rostamnia S, Khaksar S, Idris AO, Karimi-Maleh H, Yola ML, Msagati TAM. Sensitive and selective electrochemical detection of bisphenol A based on SBA-15 like Cu-PMO modified glassy carbon electrode. Food Chem 2021; 358:129763. [PMID: 34000688 DOI: 10.1016/j.foodchem.2021.129763] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2020] [Revised: 03/21/2021] [Accepted: 04/05/2021] [Indexed: 01/29/2023]
Abstract
This work reports the electrochemical detection of bisphenol A (BPA) using a novel and sensitive electrochemical sensor based on the Cu functionalized SBA-15 like periodic mesoporous organosilica-ionic liquid composite modified glassy carbon electrode (Cu@TU-PMO/IL/GCE). The structural morphology of Cu@TU-PMO is characterized by X-ray powder diffraction (XRD), energy dispersive X-ray analysis (EDX), Fourier transform infrared spectroscopy (FT-IR), transmission electron microscopy (TEM), Field emission scanning electron microscopy (FE-SEM), and Brunauer-Emmett-Teller (BET). The catalytic activity of the modified electrode toward oxidation of BPA was interrogated with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in phosphate buffer solution (pH 7.0) using the fabricated sensor. The electrochemical detection of the analyte was carried out at a neutral pH and the scan rate studies revealed that the sensor was stable. Under the optimal conditions, a linear range from 5.0 nM to 2.0 µM and 4.0 to 500 µM for detecting BPA was observed with a detection limit of 1.5 nM (S/N = 3). The sensor was applied to detect BPA in tap and seawater samples, and the accuracy of the results was validated by high-performance liquid chromatography (HPLC). The proposed method provides a powerful tool for the rapid and sensitive detection of BPA in environmental samples.
Collapse
Affiliation(s)
- Aziz Eftekhari
- Maragheh University of Medical Sciences, PO Box: 78151-55158, Maragheh, Iran.
| | - Maryam Dalili
- Organic and Nano Group (ONG), Department of Chemistry, Faculty of Science, University of Maragheh, PO BOX 55181-83111, Maragheh, Iran
| | - Ziba Karimi
- Organic and Nano Group (ONG), Department of Chemistry, Faculty of Science, University of Maragheh, PO BOX 55181-83111, Maragheh, Iran
| | - Shamila Rouhani
- Institute for Nanotechnology and Water Sustainability (iNanoWS), College of Science, Engineering and Technology, University of South Africa, Johannesburg 1709, South Africa
| | - Amir Hasanzadeh
- Maragheh University of Medical Sciences, PO Box: 78151-55158, Maragheh, Iran.
| | - Sadegh Rostamnia
- Organic and Nano Group (ONG), Department of Chemistry, Iran University of Science and Technology (IUST), PO Box 16846-13114, Tehran, Iran; Organic and Nano Group (ONG), Department of Chemistry, Faculty of Science, University of Maragheh, PO BOX 55181-83111, Maragheh, Iran.
| | - Samad Khaksar
- School of Science and Technology, The University of Georgia, Tbilisi, Georgia
| | - Azeez Olayiwola Idris
- Institute for Nanotechnology and Water Sustainability (iNanoWS), College of Science, Engineering and Technology, University of South Africa, Johannesburg 1709, South Africa
| | - Hassan Karimi-Maleh
- School of Resources and Environment, University of Electronic Science and Technology of China, P.O. Box 611731, Xiyuan Ave, Chengdu, PR China; Department of Chemical Engineering, Quchan University of Technology, Quchan 9477177870, Iran; Department of Chemical Sciences, University of Johannesburg, P.O. Box 17011, Doornfontein Campus, 2028 Johannesburg, South Africa.
| | - Mehmet Lütfi Yola
- Hasan Kalyoncu University, Faculty of Health Sciences, Department of Nutrition and Dietetics, Gaziantep, Turkey
| | - Titus A M Msagati
- Institute for Nanotechnology and Water Sustainability (iNanoWS), College of Science, Engineering and Technology, University of South Africa, Johannesburg 1709, South Africa
| |
Collapse
|
18
|
Deiminiat B, Rounaghi GH. A novel visible light photoelectrochemical aptasensor for determination of bisphenol A based on surface plasmon resonance of gold nanoparticles activated g-C3N4 nanosheets. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115122] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
19
|
Lavanya AL, Kumari KGB, Prasad KRS, Kumar Brahman P. Nickel and Tungsten Bimetallic Nanoparticles Modified Pencil Graphite Electrode: A High‐performance Electrochemical Sensor for Detection of Endocrine Disruptor Bisphenol A. ELECTROANAL 2021. [DOI: 10.1002/elan.202060277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Akkaraboyina Lakshmi Lavanya
- Electroanalytical Lab Department of Chemistry Koneru Lakshmaiah Education Foundation Vaddeswaram Guntur-522502, Andhra Pradesh India
| | - K. Gowri Bala Kumari
- Electroanalytical Lab Department of Chemistry Koneru Lakshmaiah Education Foundation Vaddeswaram Guntur-522502, Andhra Pradesh India
- Department of Chemistry Acharya Nagarjuna University Nagarjuna Nagar-522510, Andhra Pradesh India
| | - K. R. S. Prasad
- Electroanalytical Lab Department of Chemistry Koneru Lakshmaiah Education Foundation Vaddeswaram Guntur-522502, Andhra Pradesh India
| | - Pradeep Kumar Brahman
- Electroanalytical Lab Department of Chemistry Koneru Lakshmaiah Education Foundation Vaddeswaram Guntur-522502, Andhra Pradesh India
| |
Collapse
|
20
|
Tajik S, Dourandish Z, Jahani PM, Sheikhshoaie I, Beitollahi H, Shahedi Asl M, Jang HW, Shokouhimehr M. Recent developments in voltammetric and amperometric sensors for cysteine detection. RSC Adv 2021; 11:5411-5425. [PMID: 35423079 PMCID: PMC8694840 DOI: 10.1039/d0ra07614g] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2020] [Accepted: 12/06/2020] [Indexed: 12/27/2022] Open
Abstract
This review article aims to provide an overview of the recent advances in the voltammetric and amperometric sensing of cysteine (Cys). The introduction summarizes the important role of Cys as an essential amino acid, techniques for its sensing, and the utilization of electrochemical methods and chemically modified electrodes for its determination. The main section covers voltammetric and amperometric sensing of Cys based on glassy carbon electrodes, screen printed electrodes, and carbon paste electrodes, modified with various electrocatalytic materials. The conclusion section discusses the current challenges of Cys determination and the future perspectives.
Collapse
Affiliation(s)
- Somayeh Tajik
- Research Center for Tropical and Infectious Diseases, Kerman University of Medical Sciences Kerman Iran
| | - Zahra Dourandish
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman Kerman 76175-133 Iran
| | | | - Iran Sheikhshoaie
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman Kerman 76175-133 Iran
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology Kerman Iran
| | - Mehdi Shahedi Asl
- Marine Additive Manufacturing Centre of Excellence (MAMCE), University of New Brunswick Fredericton NB E3B 5A1 Canada
| | - Ho Won Jang
- Department of Materials Science and Engineering, Research Institute of Advanced Materials, Seoul National University Seoul 08826 Republic of Korea
| | - Mohammadreza Shokouhimehr
- Department of Materials Science and Engineering, Research Institute of Advanced Materials, Seoul National University Seoul 08826 Republic of Korea
| |
Collapse
|
21
|
Kaya SI, Cetinkaya A, Ozkan SA. Latest Advances in Determination of Bisphenols with Nanomaterials, Molecularly Imprinted Polymers and Aptamer Based Electrochemical Sensors. Crit Rev Anal Chem 2021; 52:1223-1243. [PMID: 33475425 DOI: 10.1080/10408347.2020.1864719] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Contamination of environmental sources such as soils, sediments and rivers and human exposure caused by several endocrine disrupting compounds (EDCs) are considered as the most challenging issues of today's world. EDCs cover a wide variety of compounds ranging from phthalates to parabens and bisphenols (BPs) are the leading group among them. BPs are widely used during the production of different plastic materials such as food and beverage containers, toys, medical equipment and baby bottles that we use in every aspect of our lives. BPs may migrate from those products to different media under certain conditions and this situation causes chronic exposure for humans and other creatures in the environment. Especially bisphenol A (BPA) and its other analogues such as bisphenol F, bisphenol S and tetrabromobisphenol that have similar structures and are preferred as alternatives to BPA cause harmful adverse effects such as endocrine disruption, neurotoxicity, genotoxicity and cytotoxicity. There are legal restrictions and prohibitions by the European Union (EU) in order to prevent possible harmful effects. Therefore, it is important to develop highly sensitive, fast, easy to use and cheap sensors for the determination of BPs in biological, environmental and commercial samples. Electrochemical sensors, which are one of the most widely, used analytical techniques, provide these conditions. Additionally, it is possible to enhance the performance of electrochemical sensors with nanomaterials, molecularly imprinted polymers or aptamer based technologies. This review aims to give comprehensive information about BPs with summarizing most recent applications of electrochemical sensors for their determination in different samples.
Collapse
Affiliation(s)
- S Irem Kaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey.,Department of Analytical Chemistry, Gulhane Faculty of Pharmacy, University of Health Sciences, Ankara, Turkey
| | - Ahmet Cetinkaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Sibel A Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| |
Collapse
|
22
|
Development of MWCNT decorated with green synthesized AgNps-based electrochemical sensor for highly sensitive detection of BPA. J APPL ELECTROCHEM 2021. [DOI: 10.1007/s10800-020-01511-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
23
|
Electrochemical detection of bisphenols in food: A review. Food Chem 2021; 346:128895. [PMID: 33421902 DOI: 10.1016/j.foodchem.2020.128895] [Citation(s) in RCA: 38] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Revised: 12/09/2020] [Accepted: 12/16/2020] [Indexed: 12/14/2022]
Abstract
Bisphenols (BPs) are worldwide used organic compounds in plastics, belonging to the group of endocrine disrupting chemicals (EDCs) which exhibits endocrine disruption to beings. Migration of BPs from food contact materials like plastic containers, epoxy coatings in metal cans and thermal papers, would results in bioaccumulation of BPs in human beings, causing adverse health effects. Therefore, sensitive and selective determination of BPs in food is needed. Among different strategies have been explored for the detection of BPs, electrochemical sensors with relatively high sensitivity and fast response are promising. This paper is devoted to comprehensively review the developed electrochemical methods for BPs sensing in food, so that to find a direction for developing low cost, high accuracy and compatibility sensors toward the sensitive and selective detection of BPs. Different electrochemical technologies categorized by recognition agents, aptamers, enzymes, molecularly imprinted polymers and nanomaterials are discussed and summarized in their mechanisms, usages, merits and limitations. The challenges and further perspectives in the development of electrochemical sensors is also discussed.
Collapse
|
24
|
Electrochemical detection and simultaneous removal of endocrine disruptor, bisphenol A using a carbon felt electrode. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2020.114907] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
25
|
Rasheed PA, Pandey RP, Jabbar KA, Mahmoud KA. Platinum nanoparticles/Ti3C2Tx (MXene) composite for the effectual electrochemical sensing of Bisphenol A in aqueous media. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2020.114934] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
26
|
Lien NT, Quoc Hung L, Hoang NT, Thu VT, Ngoc Nga DT, Hai Yen PT, Phong PH, Thu Ha VT. An Electrochemical Sensor Based on Gold Nanodendrite/Surfactant Modified Electrode for Bisphenol A Detection. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY 2020; 2020:6693595. [PMID: 33457037 PMCID: PMC7785347 DOI: 10.1155/2020/6693595] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 11/30/2020] [Accepted: 12/14/2020] [Indexed: 06/12/2023]
Abstract
In the present work, we reported the simple way to fabricate an electrochemical sensing platform to detect Bisphenol A (BPA) using galvanostatic deposition of Au on a glassy carbon electrode covered by cetyltrimethylammonium bromide (CTAB). This material (CTAB) enhances the sensitivity of electrochemical sensors with respect to the detection of BPA. The electrochemical response of the modified GCE to BPA was investigated by cyclic voltammetry and differential pulse voltammetry. The results displayed a low detection limit (22 nm) and a linear range from 0.025 to 10 µm along side with high reproducibility (RSD = 4.9% for seven independent sensors). Importantly, the prepared sensors were selective enough against interferences with other pollutants in the same electrochemical window. Notably, the presented sensors have already proven their ability in detecting BPA in real plastic water drinking bottle samples with high accuracy (recovery range = 96.60%-102.82%) and it is in good agreement with fluorescence measurements.
Collapse
Affiliation(s)
- Nguyen Thi Lien
- Department of Chemistry, Hanoi University of Science, 19 Le Thanh Tong, Hanoi, Vietnam
| | - Le Quoc Hung
- Institute of Chemistry, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam
| | - Nguyen Tien Hoang
- University of Science and Technology of Hanoi, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam
| | - Vu Thi Thu
- University of Science and Technology of Hanoi, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam
| | - Dau Thi Ngoc Nga
- University of Science and Technology of Hanoi, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam
| | - Pham Thi Hai Yen
- Institute of Chemistry, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam
| | - Pham Hong Phong
- Institute of Chemistry, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam
| | - Vu Thi Thu Ha
- Institute of Chemistry, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam
- University of Science and Technology of Hanoi, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam
| |
Collapse
|
27
|
Fadillah G, Triana S, Chasanah U, Saleh TA. Titania-nanorods modified carbon paste electrode for the sensitive voltammetric determination of BPA in exposed bottled water. SENSING AND BIO-SENSING RESEARCH 2020. [DOI: 10.1016/j.sbsr.2020.100391] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
|
28
|
Feng Y, Wang F, Wang L, Guo M, Lei Y, Feng Y, Cao Y, Yu Y. In situ growth of MoS2 on three-dimensional porous carbon for sensitive electrochemical determination of bisphenol A. J APPL ELECTROCHEM 2020. [DOI: 10.1007/s10800-020-01499-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
29
|
Mahdi ZS, Talebnia Roshan F, Nikzad M, Ezoji H. Biosynthesis of zinc oxide nanoparticles using bacteria: a study on the characterization and application for electrochemical determination of bisphenol A. INORG NANO-MET CHEM 2020. [DOI: 10.1080/24701556.2020.1835962] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- Zahra Sadat Mahdi
- Faculty of Chemical Engineering, Babol Noshirvani University of Technology, Babol, Iran
| | - Farid Talebnia Roshan
- Faculty of Chemical Engineering, Babol Noshirvani University of Technology, Babol, Iran
| | - Maryam Nikzad
- Faculty of Chemical Engineering, Babol Noshirvani University of Technology, Babol, Iran
| | - Hoda Ezoji
- Faculty of Chemical Engineering, Babol Noshirvani University of Technology, Babol, Iran
| |
Collapse
|
30
|
Negm NA, Abubshait HA, Abubshait SA, Abou Kana MTH, Mohamed EA, Betiha MM. Performance of chitosan polymer as platform during sensors fabrication and sensing applications. Int J Biol Macromol 2020; 165:402-435. [PMID: 33007321 DOI: 10.1016/j.ijbiomac.2020.09.130] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 09/08/2020] [Accepted: 09/15/2020] [Indexed: 02/07/2023]
Abstract
Chitosan is an important polymer produced from deacetylation of several sea and insects crusts. Due to its environmental fate and biological biocompatibility, it can be used in several biological and environmental applications. Sensing of biological compounds in human bodies and also in serum, blood, and different body fluids has found an important application instead of direct determination of the body fluids using complicated tools. Sensing process of biological compounds during bio-analysis of the biological systems, especially human fluids lack of several parameters including: high sensitivity, repeatability, speed of analysis and biocompatibility of the used analytical methods, especially in-vivo analysis. That was due to the time between sample handling and sample determination can change various components and concentrations of the bio-compounds. The need for in-situ analysis was directed the researchers for biosensors to overcome the upgrading problems of bio-analysis. Biosensors were the future of this issue. Chitosan can reserve as great platform for fabrication of different sensors to determine the elements, compounds and body bioactive compounds. The presence of different terminal amino and hydroxyl groups within chitosan framework facilitates the immobilization of different biomarkers to be used as sensing elements for the determined compounds. The use of chitosan as sensors platform was enhanced by using chitosan in its nanoforms.
Collapse
Affiliation(s)
- Nabel A Negm
- Egyptian Petroleum Research Institute, Nasr City, Cairo, Egypt.
| | - Haya A Abubshait
- Basic Sciences Department, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Samar A Abubshait
- Department of Chemistry, College of Science, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia; Basic & Applied Scientific Research Center, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Maram T H Abou Kana
- National Institute of Laser Enhanced Sciences (NILES), Cairo University, Egypt
| | - Eslam A Mohamed
- Egyptian Petroleum Research Institute, Nasr City, Cairo, Egypt
| | | |
Collapse
|
31
|
A layered nanocomposite of laccase, chitosan, and Fe3O4 nanoparticles-reduced graphene oxide for the nanomolar electrochemical detection of bisphenol A. Mikrochim Acta 2020; 187:262. [DOI: 10.1007/s00604-020-4223-x] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Accepted: 03/07/2020] [Indexed: 12/20/2022]
|
32
|
One-step electroreduction preparation of multilayered reduced graphene oxide/gold-palladium nanohybrid as a proficient electrocatalyst for development of sensitive hydrazine sensor. J Colloid Interface Sci 2020; 566:473-484. [DOI: 10.1016/j.jcis.2020.01.105] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 01/18/2020] [Accepted: 01/28/2020] [Indexed: 12/25/2022]
|
33
|
Nanocomposites consisting of nanoporous platinum-silicon and graphene for electrochemical determination of bisphenol A. Mikrochim Acta 2020; 187:241. [DOI: 10.1007/s00604-020-4219-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2019] [Accepted: 03/07/2020] [Indexed: 01/19/2023]
|
34
|
Khan MS, Ameer H, Ali A, Manzoor R, Yang L, Feng R, Jiang N, Wei Q. Electrochemiluminescence behaviour of silver/silver orthophosphate/graphene oxide quenched by Pd@Au core-shell nanoflowers for ultrasensitive detection of insulin. Biosens Bioelectron 2020; 147:111767. [DOI: 10.1016/j.bios.2019.111767] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Revised: 09/24/2019] [Accepted: 10/07/2019] [Indexed: 12/21/2022]
|
35
|
Ramu AG, Telmenbayar L, Theerthagiri J, Yang D, Song M, Choi D. Synthesis of a hierarchically structured Fe3O4–PEI nanocomposite for the highly sensitive electrochemical determination of bisphenol A in real samples. NEW J CHEM 2020. [DOI: 10.1039/d0nj03830j] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
In this work, a novel, highly sensitive and cost-effective sensing electrode was fabricated for the sensitive detection of bisphenol A in milk and water samples.
Collapse
Affiliation(s)
- A. G. Ramu
- Department of Materials Science and Engineering
- Hongik University
- 2639-Sejong-ro
- Jochiwon-eup
- Sejong-city
| | - L. Telmenbayar
- Department of Materials Science and Engineering
- Hongik University
- 2639-Sejong-ro
- Jochiwon-eup
- Sejong-city
| | - J. Theerthagiri
- Centre of Excellence for Energy Research, Sathyabama Institute of Science and Technology (Deemed to be University)
- Chennai 600119
- India
- Department of Chemistry and Research Institute of Natural Sciences
- Gyeongsang National University
| | - D. Yang
- Department of Materials Science and Engineering
- Hongik University
- 2639-Sejong-ro
- Jochiwon-eup
- Sejong-city
| | - M. Song
- Department of Materials Science and Engineering
- Hongik University
- 2639-Sejong-ro
- Jochiwon-eup
- Sejong-city
| | - Dongjin Choi
- Department of Materials Science and Engineering
- Hongik University
- 2639-Sejong-ro
- Jochiwon-eup
- Sejong-city
| |
Collapse
|
36
|
Ponnaiah SK, Prakash P, Muthupandian S. Ultrasonic energy-assisted in-situ synthesis of Ru 0/PANI/g-C 3N 4 nanocomposite: Application for picomolar-level electrochemical detection of endocrine disruptor (Bisphenol-A) in humans and animals. ULTRASONICS SONOCHEMISTRY 2019; 58:104629. [PMID: 31450371 DOI: 10.1016/j.ultsonch.2019.104629] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2019] [Revised: 06/05/2019] [Accepted: 06/05/2019] [Indexed: 06/10/2023]
Abstract
Bisphenol A (BPA) is an endocrine-disrupting chemical which resembles structurally the hormone estrogen. Even a trace amount of BPA can bind estrogen receptors resulting in the inducement of reproductive disorders, cancers and problems related to sexual growth such as manliness in female and womanliness in male. So the determination of BPA in human and animal bodies is very essential. For this purpose, a new nanocomposite composed of ruthenium nanoparticles, polyaniline and graphitic carbon nitride (Ru0/PANI/g-C3N4) has been synthesized ultrasonically (40 ± 3 kHz, 200 W). A modification on glassy carbon electrode (GCE) with the nanocomposite detects BPA in human and animal urine samples with wide linear range (0.01-1.1 µM) and the limit of detection is pico molar-level. The synthesized nanocomposite was characterized by Ultraviolet-Visible and Fourier Transform-Infra Red spectroscopies, thermo gravimetric analysis, transmission electron microscopy, X-ray diffraction study, energy dispersive X-ray analysis, and elemental mapping analysis. This sensing system is selective, stable and reusable, by which the detection of BPA in various physiological fluids is very much possible.
Collapse
Affiliation(s)
| | | | - Saravanan Muthupandian
- Department of Microbiology and Immunology, Institute of Biomedical Sciences, College of Health Science, Mekelle University, Mekelle 1871, Ethiopia
| |
Collapse
|
37
|
Wang W, Xu S, Li N, Huang Z, Su B, Chen X. Sulfur and phosphorus co-doped graphene quantum dots for fluorescent monitoring of nitrite in pickles. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2019; 221:117211. [PMID: 31158765 DOI: 10.1016/j.saa.2019.117211] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/24/2018] [Revised: 05/05/2019] [Accepted: 05/26/2019] [Indexed: 06/09/2023]
Abstract
Doping graphene quantum dots (GQDs) with heteroatoms can change their band gap and electronic density, thus enhancing their fluorescence quantum yield (QY). In this work, we for the first time reported a nontoxic, rapid, and one-pot hydrothermal method to synthesize sulfur and phosphorus co-doped GQDs (S, P-GQDs). Citric acid was functioned as a carbon source, whereas sodium phytate and anhydrous sodium sulfate are used as the P and S sources, respectively, in this bottom-up synthesis. The resulting S, P-GQDs exhibit high heteroatomic doping ratios of 9.66 at.% for S and 3.34 at.% for P, and higher QY than those obtained from monoatomic doped GQDs. Additionally, the as-prepared S, P-GQDs exhibit excitation-dependent behavior, pH sensitivity between 8.0 and 13.0, high tolerance of ionic strength. More importantly, the as-synthesized S, P-GQDs show a sensitive and selective behavior for sensing nitrite (NO2-) in the concentration range of 0.7-9 μmol/L, and the detection limit was as low as 0.3 μmol/L. Additionally, the S, P-GQDs was successfully used in detecting NO2- in pickled foods, showing their promise for potential applications in realistic analysis.
Collapse
Affiliation(s)
- Weijie Wang
- College of Food and Biological Engineering, Fujian Provincial Key Laboratory of Food Microbiology and Enzyme Engineering, Jimei University, Xiamen 361021, China
| | - Shifen Xu
- College of Food and Biological Engineering, Fujian Provincial Key Laboratory of Food Microbiology and Enzyme Engineering, Jimei University, Xiamen 361021, China
| | - Ning Li
- College of Food and Biological Engineering, Fujian Provincial Key Laboratory of Food Microbiology and Enzyme Engineering, Jimei University, Xiamen 361021, China
| | - Zhiyong Huang
- College of Food and Biological Engineering, Fujian Provincial Key Laboratory of Food Microbiology and Enzyme Engineering, Jimei University, Xiamen 361021, China
| | - Bingyuan Su
- Xiamen Center for Disease Control and Prevention, Xiamen 361021, China
| | - Xiaomei Chen
- College of Food and Biological Engineering, Fujian Provincial Key Laboratory of Food Microbiology and Enzyme Engineering, Jimei University, Xiamen 361021, China.
| |
Collapse
|
38
|
Zhang X, Yang S, Chen W, Li Y, Wei Y, Luo A. Magnetic Fluorescence Molecularly Imprinted Polymer Based on FeO x/ZnS Nanocomposites for Highly Selective Sensing of Bisphenol A. Polymers (Basel) 2019; 11:polym11071210. [PMID: 31331050 PMCID: PMC6680805 DOI: 10.3390/polym11071210] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2019] [Revised: 07/08/2019] [Accepted: 07/09/2019] [Indexed: 01/05/2023] Open
Abstract
In this study, magnetic fluorescence molecularly imprinted polymers were fabricated and used for the selective separation and fluorescence sensing of trace bisphenol A (BPA) in environmental water samples. The carboxyl-functionalized FeOx magnetic nanoparticles were conjugated with mercaptoethylamine-capped Mn2+ doped ZnS quantum dots to prepare magnetic FeOx and ZnS quantum dot nanoparticles (FeOx/ZnS NPs). Additionally, molecular imprinting on the FeOx/ZnS NPs was employed to synthesize core-shell molecularly imprinted polymers. The resulting nanoparticles were well characterized using transmission electron microscopy, Fourier transform infrared spectra, vibrating sample magnetometer and fluorescence spectra, and the adsorption behavior was investigated. Binding experiments showed that the molecularly imprinted FeOX/ZnS NPs (FeOx/ZnS@MIPs) exhibited rapid fluorescent and magnetic responses, and high selectivity and sensitivity for the detection of bisphenol A (BPA). The maximum adsorption capacity of FeOx/ZnS@MIPs was 50.92 mg·g-1 with an imprinting factor of 11.19. Under optimal conditions, the constructed fluorescence magnetic molecularly imprinted polymers presented good linearity from 0 to 80 ng mL-1 with a detection limit of 0.3626 ng mL-1 for BPA. Moreover, the proposed fluorescence magnetic polymers were successfully applied to on-site magnetic separation and real-time fluorescence analysis of target molecule in real samples.
Collapse
Affiliation(s)
- Xin Zhang
- School of Life Science and Technology, Nanyang Normal University, Nanyang 473061, China.
- School of Life Science, Beijing Institute of Technology, No.5 Zhongguancun South Street, Beijing 100081, China.
| | - Shu Yang
- School of Life Science, Beijing Institute of Technology, No.5 Zhongguancun South Street, Beijing 100081, China
| | - Weijie Chen
- School of Life Science, Beijing Institute of Technology, No.5 Zhongguancun South Street, Beijing 100081, China
| | - Yansong Li
- School of Life Science and Technology, Nanyang Normal University, Nanyang 473061, China
| | - Yuping Wei
- School of Life Science and Technology, Nanyang Normal University, Nanyang 473061, China
| | - Aiqin Luo
- School of Life Science, Beijing Institute of Technology, No.5 Zhongguancun South Street, Beijing 100081, China
| |
Collapse
|
39
|
Vieira Jodar L, Orzari LO, Storti Ortolani T, Assumpção MHMT, Vicentini FC, Janegitz BC. Electrochemical Sensor Based on Casein and Carbon Black for Bisphenol A Detection. ELECTROANAL 2019. [DOI: 10.1002/elan.201900176] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Letícia Vieira Jodar
- Department of Nature Sciences, Mathematics and EducationFederal University of São Carlos 13600-970 Araras, SP Brazil
| | - Luiz Otávio Orzari
- Department of Nature Sciences, Mathematics and EducationFederal University of São Carlos 13600-970 Araras, SP Brazil
| | - Túlio Storti Ortolani
- Department of Nature Sciences, Mathematics and EducationFederal University of São Carlos 13600-970 Araras, SP Brazil
| | - Mônica H. M. T. Assumpção
- Center of Nature SciencesFederal University of São Carlos Rod. Lauri Simões de Barros km 12 Buri, SP Brazil
| | - Fernando C. Vicentini
- Center of Nature SciencesFederal University of São Carlos Rod. Lauri Simões de Barros km 12 Buri, SP Brazil
| | - Bruno C. Janegitz
- Department of Nature Sciences, Mathematics and EducationFederal University of São Carlos 13600-970 Araras, SP Brazil
| |
Collapse
|
40
|
Manikandan VS, Adhikari B, Chen A. Nanomaterial based electrochemical sensors for the safety and quality control of food and beverages. Analyst 2019; 143:4537-4554. [PMID: 30113611 DOI: 10.1039/c8an00497h] [Citation(s) in RCA: 78] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
The issue of foodborne related illnesses due to additives and contaminants poses a significant challenge to food processing industries. The efficient, economical and rapid analysis of food additives and contaminants is therefore necessary in order to minimize the risk of public health issues. Electrochemistry offers facile and robust analytical methods, which are desirable for food safety and quality assessment over conventional analytical techniques. The development of a wide array of nanomaterials has paved the way for their applicability in the design of high-performance electrochemical sensing devices for medical diagnostics and environment and food safety. The design of nanomaterial based electrochemical sensors has garnered enormous attention due to their high sensitivity and selectivity, real-time monitoring and ease of use. This review article focuses predominantly on the synthesis and applications of different nanomaterials for the electrochemical determination of some common additives and contaminants, including hydrazine (N2H4), malachite green (MG), bisphenol A (BPA), ascorbic acid (AA), caffeine, caffeic acid (CA), sulfite (SO32-) and nitrite (NO2-), which are widely found in food and beverages. Important aspects, such as the design, fabrication and characterization of graphene-based materials, gold nanoparticles, mono- and bimetallic nanoparticles and metal nanocomposites, sensitivity and selectivity for electrochemical sensor development are addressed. High-performance nanomaterial based electrochemical sensors have and will continue to have myriad prospects in the research and development of advanced analytical devices for the safety and quality control of food and beverages.
Collapse
Affiliation(s)
- Venkatesh S Manikandan
- Electrochemical Technology Centre, Department of Chemistry, University of Guelph, 50 Stone Road E, Guelph, Ontario N1G 2W1, Canada.
| | | | | |
Collapse
|
41
|
Zou J, Zhao GQ, Teng J, Liu Q, Jiang XY, Jiao FP, Yu JG. Highly sensitive detection of bisphenol A in real water samples based on in-situ assembled graphene nanoplatelets and gold nanoparticles composite. Microchem J 2019. [DOI: 10.1016/j.microc.2018.11.040] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
42
|
Zainul R, Abd Azis N, Md Isa I, Hashim N, Ahmad MS, Saidin MI, Mukdasai S. Zinc/Aluminium⁻Quinclorac Layered Nanocomposite Modified Multi-Walled Carbon Nanotube Paste Electrode for Electrochemical Determination of Bisphenol A. SENSORS 2019; 19:s19040941. [PMID: 30813385 PMCID: PMC6413131 DOI: 10.3390/s19040941] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Revised: 02/15/2019] [Accepted: 02/15/2019] [Indexed: 01/25/2023]
Abstract
This paper presents the application of zinc/aluminium-layered double hydroxide-quinclorac (Zn/Al-LDH-QC) as a modifier of multiwalled carbon nanotubes (MWCNT) paste electrode for the determination of bisphenol A (BPA). The Zn/Al-LDH-QC/MWCNT morphology was examined by a transmission electron microscope and a scanning electron microscope. Electrochemical impedance spectroscopy was utilized to investigate the electrode interfacial properties. The electrochemical responses of the modified electrode towards BPA were thoroughly evaluated by using square-wave voltammetry technique. The electrode demonstrated three linear plots of BPA concentrations from 3.0 × 10−8–7.0 × 10−7 M (R2 = 0.9876), 1.0 × 10−6–1.0 × 10−5 M (R2 = 0.9836) and 3.0 × 10−5–3.0 × 10−4 M (R2 = 0.9827) with a limit of detection of 4.4 × 10−9 M. The electrode also demonstrated good reproducibility and stability up to one month. The presence of several metal ions and organic did not affect the electrochemical response of BPA. The electrode is also applicable for BPA determination in baby bottle and mineral water samples with a range of recovery between 98.22% and 101.02%.
Collapse
Affiliation(s)
- Rahadian Zainul
- Department of Chemistry, Faculty of Mathematics and Natural Science, Universitas Negeri Padang, West Sumatera 25171, Indonesia.
| | - Nurashikin Abd Azis
- Department of Chemistry, Faculty of Science and Mathemathics, Universiti Pendidikan Sultan Idris, Tanjong Malim 35900, Perak, Malaysia.
| | - Illyas Md Isa
- Department of Chemistry, Faculty of Science and Mathemathics, Universiti Pendidikan Sultan Idris, Tanjong Malim 35900, Perak, Malaysia.
- Nanotechnology Research Centre, Faculty of Science and Mathemathics, Universiti Pendidikan Sultan Idris, Tanjong Malim 35900, Perak, Malaysia.
| | - Norhayati Hashim
- Department of Chemistry, Faculty of Science and Mathemathics, Universiti Pendidikan Sultan Idris, Tanjong Malim 35900, Perak, Malaysia.
- Nanotechnology Research Centre, Faculty of Science and Mathemathics, Universiti Pendidikan Sultan Idris, Tanjong Malim 35900, Perak, Malaysia.
| | - Mohamad Syahrizal Ahmad
- Department of Chemistry, Faculty of Science and Mathemathics, Universiti Pendidikan Sultan Idris, Tanjong Malim 35900, Perak, Malaysia.
- Nanotechnology Research Centre, Faculty of Science and Mathemathics, Universiti Pendidikan Sultan Idris, Tanjong Malim 35900, Perak, Malaysia.
| | - Mohamad Idris Saidin
- Department of Chemistry, Faculty of Science and Mathemathics, Universiti Pendidikan Sultan Idris, Tanjong Malim 35900, Perak, Malaysia.
| | - Siriboon Mukdasai
- Department of Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen 40002, Thailand.
| |
Collapse
|
43
|
A direct “touch” approach for gold nanoflowers decoration on graphene/ionic liquid composite modified electrode with good properties for sensing bisphenol A. Talanta 2019; 191:400-408. [DOI: 10.1016/j.talanta.2018.08.093] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Revised: 08/27/2018] [Accepted: 08/31/2018] [Indexed: 12/19/2022]
|
44
|
Palygorskite Supported AuPd Alloy Nanoparticles as Efficient Nano-Catalysts for the Reduction of Nitroarenes and Dyes at Room Temperature. NANOMATERIALS 2018; 8:nano8121000. [PMID: 30513941 PMCID: PMC6315398 DOI: 10.3390/nano8121000] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/17/2018] [Revised: 11/28/2018] [Accepted: 11/30/2018] [Indexed: 12/12/2022]
Abstract
In this work, AuPd alloy palygorskite based Pal-NH2@AuPd nano-catalysts were prepared and used as catalysts for the reduction of nitroarenes and dyes at room temperature. The surface of palygorskite (Pal) was first modified with 3-aminpropyltriethoxysilane, and then covered with AuPd alloy nanoparticles through co-reduction of HAuCl4 and K2PdCl4. The morphology and structures of the Pal-NH2@AuPd nano-catalysts were characterized by X-ray diffraction (XRD), energy-dispersive X-ray spectroscopy (EDS) and transmission electron microscopy (TEM). The as-synthesized Pal-NH2@AuPd nano-catalysts displayed excellent catalytic performance in reducing 4-nitrophenol (4-NP) and various other nitroaromatic compounds. Moreover, the catalytic activities of the Pal-NH2@AuPd nano-catalysts were adjustable via changing the atomic ratio of AuPd alloy nanoparticles, leading to the Pal-NH2@Au48Pd52 component as having the best atomic ratio. The Pal-NH2@Au48Pd52 continued to display good catalytic stability after being reused for several cycles and there were no obvious changes, either of the morphology or the particle size distribution of the nano-catalysts. Furthermore, these Pal-NH2@Au48Pd52 nano-catalysts also provided a convenient and accessible way for the degradation of dyes in artificial industrial wastewater.
Collapse
|
45
|
Tian C, Chen D, Lu N, Li Y, Cui R, Han Z, Zhang G. Electrochemical bisphenol A sensor based on nanoporous PtFe alloy and graphene modified glassy carbon electrode. J Electroanal Chem (Lausanne) 2018. [DOI: 10.1016/j.jelechem.2018.10.023] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
46
|
Ulubay Karabiberoğlu Ş. Sensitive Voltammetric Determination of Bisphenol A Based on a Glassy Carbon Electrode Modified with Copper Oxide-Zinc Oxide Decorated on Graphene Oxide. ELECTROANAL 2018. [DOI: 10.1002/elan.201800415] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
47
|
Fan Z, Fan L, Shuang S, Dong C. Highly sensitive photoelectrochemical sensing of bisphenol A based on zinc phthalocyanine/TiO2 nanorod arrays. Talanta 2018; 189:16-23. [DOI: 10.1016/j.talanta.2018.06.043] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2018] [Revised: 06/07/2018] [Accepted: 06/11/2018] [Indexed: 12/11/2022]
|
48
|
Ianesko F, Alves de Lima C, Antoniazzi C, Santana ER, Piovesan JV, Spinelli A, Galli A, Guimarães de Castro E. Simultaneous Electrochemical Determination of Hydroquinone and Bisphenol A using a Carbon Paste Electrode Modified with Silver Nanoparticles. ELECTROANAL 2018. [DOI: 10.1002/elan.201800074] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Affiliation(s)
- Felipe Ianesko
- Universidade Estadual do Centro-Oeste; Campus CEDETEG, Departamento de Química; 85040-080 - Guarapuava, PR Brazil
| | - Camila Alves de Lima
- Universidade Estadual do Centro-Oeste; Campus CEDETEG, Departamento de Química; 85040-080 - Guarapuava, PR Brazil
| | - Cristiane Antoniazzi
- Universidade Estadual do Centro-Oeste; Campus CEDETEG, Departamento de Química; 85040-080 - Guarapuava, PR Brazil
| | - Edson Roberto Santana
- Universidade Federal de Santa Catarina; Campus Reitor João David Ferreira Lima, Departamento de Química - CFM; 88040-900 - Florianópolis, SC Brazil
| | - Jamille Valéria Piovesan
- Universidade Federal de Santa Catarina; Campus Reitor João David Ferreira Lima, Departamento de Química - CFM; 88040-900 - Florianópolis, SC Brazil
| | - Almir Spinelli
- Universidade Federal de Santa Catarina; Campus Reitor João David Ferreira Lima, Departamento de Química - CFM; 88040-900 - Florianópolis, SC Brazil
| | - Andressa Galli
- Universidade Estadual do Centro-Oeste; Campus CEDETEG, Departamento de Química; 85040-080 - Guarapuava, PR Brazil
| | - Eryza Guimarães de Castro
- Universidade Estadual do Centro-Oeste; Campus CEDETEG, Departamento de Química; 85040-080 - Guarapuava, PR Brazil
| |
Collapse
|
49
|
Gholivand MB, Akbari A. A novel and high sensitive MWCNTs-nickel carbide/hollow fiber-pencil graphite modified electrode for in situ ultra-trace analysis of bisphenol A. J Electroanal Chem (Lausanne) 2018. [DOI: 10.1016/j.jelechem.2018.03.065] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
50
|
Pei DN, Zhang AY, Pan XQ, Si Y, Yu HQ. Electrochemical Sensing of Bisphenol A on Facet-Tailored TiO2 Single Crystals Engineered by Inorganic-Framework Molecular Imprinting Sites. Anal Chem 2018; 90:3165-3173. [DOI: 10.1021/acs.analchem.7b04466] [Citation(s) in RCA: 53] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Affiliation(s)
- Dan-Ni Pei
- CAS Key Laboratory of Urban Pollutant Conversion, Department of Chemistry, University of Science & Technology of China, Hefei, 230026, China
| | - Ai-Yong Zhang
- CAS Key Laboratory of Urban Pollutant Conversion, Department of Chemistry, University of Science & Technology of China, Hefei, 230026, China
- Department of Municipal Engineering, Hefei University of Technology, Hefei, 230009, China
| | - Xiao-Qiang Pan
- CAS Key Laboratory of Urban Pollutant Conversion, Department of Chemistry, University of Science & Technology of China, Hefei, 230026, China
| | - Yang Si
- CAS Key Laboratory of Urban Pollutant Conversion, Department of Chemistry, University of Science & Technology of China, Hefei, 230026, China
| | - Han-Qing Yu
- CAS Key Laboratory of Urban Pollutant Conversion, Department of Chemistry, University of Science & Technology of China, Hefei, 230026, China
| |
Collapse
|