2
|
Du J, Zhao F, Zeng B. Preparation of functionalized graphene and ionic liquid co-doped polypyrrole solid phase microextraction coating for the detection of benzoates preservatives. Talanta 2021; 228:122231. [DOI: 10.1016/j.talanta.2021.122231] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 02/09/2021] [Accepted: 02/13/2021] [Indexed: 01/12/2023]
|
3
|
Tian Y, Feng X, Zhang Y, Yu Q, Wang X, Tian M. Determination of Volatile Water Pollutants Using Cross-Linked Polymeric Ionic Liquid as Solid Phase Micro-Extraction Coatings. Polymers (Basel) 2020; 12:polym12020292. [PMID: 32024255 PMCID: PMC7077427 DOI: 10.3390/polym12020292] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Revised: 01/25/2020] [Accepted: 01/26/2020] [Indexed: 11/25/2022] Open
Abstract
Ionic liquids found a wide application in catalysis and extraction due to their unique properties. Herein, ethylene glycol dimethacrylate as the cross-linker and 1-vinyl-3- butylimidazolium tetrafluoroborate as functional monomer via thermally initiated free-radical polymerization was prepared as a novel copolymer solid phase micro-extraction (SPME) coating. A surface modified stainless-steel wire was implemented as the substrate. Factors affecting the extraction performances of the copolymer, including the molar ratio of monomers to cross-linkers, the amount of porogen agent, and polymerization time were evaluated and optimized. To evaluate the extraction performance, five commonly seen polycyclic aromatic hydrocarbons (PAHs) were taken as the analytical targets. The potential factors affecting extraction efficiency were optimized. The as-prepared SPME device, coupled with gas chromatography, was successfully applied for the determination of PAHs in water samples. The wide linear range, low detection limit, good reproducibility, selectivity, and excellent thermal stability indicate the promising application of the newly developed SPME fiber in environmental monitoring as well as in other samples having complex matrices.
Collapse
Affiliation(s)
- Yuan Tian
- Division of Advanced Manufacturing, Tsinghua Shenzhen International Graduate School, Shenzhen 518055, China;
| | - Xilan Feng
- School of Chemistry and Chemical Engineering, Henan Institute of Science and Technology, Xinxiang 453003, China; (X.F.); (Y.Z.); (M.T.)
| | - Yuping Zhang
- School of Chemistry and Chemical Engineering, Henan Institute of Science and Technology, Xinxiang 453003, China; (X.F.); (Y.Z.); (M.T.)
| | - Quan Yu
- Division of Advanced Manufacturing, Tsinghua Shenzhen International Graduate School, Shenzhen 518055, China;
- Correspondence: (Q.Y.); (X.W.); Tel.: +86-755-2603-5201 (Q.Y.); +86-755-2603-6618 (X.W.)
| | - Xiaohao Wang
- Division of Advanced Manufacturing, Tsinghua Shenzhen International Graduate School, Shenzhen 518055, China;
- Correspondence: (Q.Y.); (X.W.); Tel.: +86-755-2603-5201 (Q.Y.); +86-755-2603-6618 (X.W.)
| | - Mengkui Tian
- School of Chemistry and Chemical Engineering, Henan Institute of Science and Technology, Xinxiang 453003, China; (X.F.); (Y.Z.); (M.T.)
| |
Collapse
|
5
|
Zheng J, Huang J, Yang Q, Ni C, Xie X, Shi Y, Sun J, Zhu F, Ouyang G. Fabrications of novel solid phase microextraction fiber coatings based on new materials for high enrichment capability. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.08.021] [Citation(s) in RCA: 83] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
6
|
Wang W, Li Z, Wang W, Zhang L, Zhang S, Wang C, Wang Z. Microextraction of polycyclic aromatic hydrocarbons by using a stainless steel fiber coated with nanoparticles made from a porous aromatic framework. Mikrochim Acta 2017; 185:20. [PMID: 29594554 DOI: 10.1007/s00604-017-2577-5] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2017] [Accepted: 11/17/2017] [Indexed: 11/27/2022]
Abstract
A porous aromatic framework of type PAF-6 was synthesized and explored as a coating onto a steel wire for using in solid-phase microextraction of polycyclic aromatic hydrocarbons (PAHs), phthalate plasticizers, and n-alkanes. The extraction temperature, extraction time, salt concentration, agitation speed, desorption temperature, and desorption time were optimized. This method for SPME resulted in the enrichment factors ranging from 122 to 1090 for PAHs (naphthalene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene), from 122 to 271 for plasticizers (diisobutyl phthalate, dibutyl phthalate, benzyl butyl phthalate, dicyclohexyl phthalate), and from 9 to 113 for n-alkanes (n-undecane, n-dodecane, n-tridecane, n-tetradecane, n-pentadecane, n-hexadecane, n-octadecane and n-eicosane). The good extraction of the PAHs is assumed to be due to their π-stacking interaction and hydrophobic effect. The PAF-6 coated fibers are durable and can be reused more than 100 times without significant loss of extraction performance. In combination with GC-MS detection, the method has limits of detection in the range from 0.8 to 4.2 ng L-1 in case of PAHs. The relative standard deviations for five replicate determinations of the PAHs by using one fiber are in the range from 5.2 to 8.5%. When using different fibers, they range from 7.1 to 9.6%. The recoveries of PAHs from water samples at a spiking level of 20 ng L-1 are in the range from 89.5 to 103.1%, with relative standard deviations ranging from 4.0 to 9.3%. Graphical abstract A porous aromatic framework of type PAF-6 was synthesized and used as a novel coating for the solid-phase microextraction of polycyclic aromatic hydrocarbons prior to their determination by gas chromatography with mass spectrometric detection.
Collapse
Affiliation(s)
- Wenchang Wang
- Department of Chemistry, College of Science, Hebei Agricultural University, Baoding, 071001, China
| | - Zhi Li
- Department of Chemistry, College of Science, Hebei Agricultural University, Baoding, 071001, China
| | - Wenjin Wang
- Department of Chemistry, College of Science, Hebei Agricultural University, Baoding, 071001, China
| | - Lihong Zhang
- College of Food Science and Technology, Hebei Agricultural University, Baoding, 071001, China
| | - Shuaihua Zhang
- Department of Chemistry, College of Science, Hebei Agricultural University, Baoding, 071001, China.
| | - Chun Wang
- Department of Chemistry, College of Science, Hebei Agricultural University, Baoding, 071001, China
| | - Zhi Wang
- Department of Chemistry, College of Science, Hebei Agricultural University, Baoding, 071001, China. .,College of Food Science and Technology, Hebei Agricultural University, Baoding, 071001, China.
| |
Collapse
|
7
|
de Toffoli AL, Maciel EVS, Fumes BH, Lanças FM. The role of graphene-based sorbents in modern sample preparation techniques. J Sep Sci 2017; 41:288-302. [DOI: 10.1002/jssc.201700870] [Citation(s) in RCA: 67] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2017] [Revised: 09/18/2017] [Accepted: 09/19/2017] [Indexed: 12/13/2022]
Affiliation(s)
- Ana Lúcia de Toffoli
- Institute of Chemistry of São Carlos; University of São Paulo,; São Carlos SP Brazil
| | | | - Bruno Henrique Fumes
- Institute of Chemistry of São Carlos; University of São Paulo,; São Carlos SP Brazil
| | - Fernando Mauro Lanças
- Institute of Chemistry of São Carlos; University of São Paulo,; São Carlos SP Brazil
| |
Collapse
|