Hao J, Feng R, Li J, Gao W, Yu J, Tang K. A high-performance standalone planar FAIMS system for effective detection of chemical warfare agents via TSPSO algorithm. Talanta 2024; 269:125516. [PMID: 38070286 DOI: 10.1016/j.talanta.2023.125516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 11/28/2023] [Accepted: 12/03/2023] [Indexed: 01/05/2024]
Abstract
A high-performance standalone planar field asymmetric waveform ion mobility spectrometry (p-FAIMS) system with a deconvolution algorithm (two-step particle swarm optimization algorithm, TSPSO) for overlapping peaks was developed to effectively detect chemical warfare agents (CWAs). Four CWA simulants were applied in this study to systemically evaluate the performance of the standalone p-FAIMS system. The experimental results showed that each CWA simulant in the mixture can be positively identified by carefully comparing the compensation voltage (CV) value of each peak in the FAIMS spectra for the mixture to the ones in the spectra acquired by using the same FAIMS system for the pure CWA simulant standards. The FAIMS spectrum of the CWA simulant mixture might consist of multiple overlapping peaks, which would be difficult to accurately determine the CV value for each CWA simulant peak. This problem has been effectively resolved in this study by deconvoluting the overlapping peaks via the TSPSO algorithm. As the effective peak deconvolution via TSPSO requires the degree of overlap between each FAIMS peak to be lower than a specific value, the flow rate of FAIMS carrier gas was decreased to further improve the resolution of the p-FAIMS system. After the accurate deconvolution, the resolution of original FAIMS spectrum can also be enhanced to achieve baseline separation by using TSPSO algorithm to narrow the peak width of each peak. The experimental results in this study demonstrated the possibility of using TSPSO algorithm to achieve high-resolution on a typically low-resolution standalone FAIMS. The concept in this study can potentially be applied to any low-resolution instruments to achieve high-resolution results.
Collapse
Affiliation(s)
- Jie Hao
- Institute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Ningbo University, Ningbo, 315211, PR China; Zhenhai Institute of Mass Spectrometry, Ningbo, 315211, PR China; Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo, 315211, PR China
| | - Rong Feng
- Institute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Ningbo University, Ningbo, 315211, PR China; Zhenhai Institute of Mass Spectrometry, Ningbo, 315211, PR China; School of Material Science and Chemical Engineering, Ningbo University, Ningbo, 315211, PR China
| | - Junhui Li
- Institute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Ningbo University, Ningbo, 315211, PR China; Zhenhai Institute of Mass Spectrometry, Ningbo, 315211, PR China; School of Material Science and Chemical Engineering, Ningbo University, Ningbo, 315211, PR China.
| | - Wenqing Gao
- Institute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Ningbo University, Ningbo, 315211, PR China; Zhenhai Institute of Mass Spectrometry, Ningbo, 315211, PR China; School of Material Science and Chemical Engineering, Ningbo University, Ningbo, 315211, PR China
| | - Jiancheng Yu
- Institute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Ningbo University, Ningbo, 315211, PR China; Zhenhai Institute of Mass Spectrometry, Ningbo, 315211, PR China; Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo, 315211, PR China
| | - Keqi Tang
- Institute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Ningbo University, Ningbo, 315211, PR China; Zhenhai Institute of Mass Spectrometry, Ningbo, 315211, PR China; School of Material Science and Chemical Engineering, Ningbo University, Ningbo, 315211, PR China.
| |
Collapse
|
2
|
Shi L, Habib A, Bi L, Hong H, Begum R, Wen L. Ambient Ionization Mass Spectrometry: Application and Prospective. Crit Rev Anal Chem 2022:1-50. [PMID: 36206159 DOI: 10.1080/10408347.2022.2124840] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/10/2022]
Abstract
Mass spectrometry (MS) is a formidable analytical tool for the analysis of non-polar to polar compounds individually and/or from mixtures, providing information on the molecular weights and chemical structures of the analytes. During the last more than one-decade, ambient ionization mass spectrometry (AIMS) has developed quickly, producing a wide range of platforms and proving scientific improvements in a variety of domains, from biological imaging to quick quality control. These methods have made it possible to detect target analytes in real time without sample preparation in an open environment, and they can be connected to any MS system with an atmospheric pressure interface. They also have the ability to analyze explosives, illicit drugs, disease diagnostics, drugs in biological samples, adulterants in food and agricultural products, reaction progress, and environmental monitoring. The development of novel ambient ionization techniques, such as probe electrospray ionization, paper spray ionization, and fiber spray ionization, employed even at picolitre to femtolitre solution levels to provide femtogram to attogram levels of the target analytes. The special characteristic of this ambient ion source, which has been extensively used, is the noninvasive property of PESI of examination of biological real samples. The results in the current review supports the idea that AIMS has emerged as a pioneer in MS-based approaches and that methods will continue to be developed along with improvements to existing ones in the near future.
Collapse
Affiliation(s)
- Lulu Shi
- Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai, China
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
| | - Ahsan Habib
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, Zhejiang, China
- Department of Chemistry, University of Dhaka, Dhaka, Bangladesh
| | - Lei Bi
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, Zhejiang, China
| | - Huanhuan Hong
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, Zhejiang, China
| | - Rockshana Begum
- Department of Chemistry, Shahjalal University of Science and Technology, Sylhet, Bangladesh
| | - Luhong Wen
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, Zhejiang, China
| |
Collapse
|
3
|
Li B, Kong J, Zhang L, Fu W, Zhang Z, Li C. The ionization process of chemical warfare agent simulants in low temperature plasma ionization. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2020; 26:341-350. [PMID: 32819167 DOI: 10.1177/1469066720951943] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The application of low-temperature plasma ionization technology in the chemical warfare agent detection was mostly focused on the research of rapid detection methods. Limited studies are available on the ionization process of chemical warfare agents in low temperature plasma. Through the intensity of protonated molecules of dimethyl methylphosphonate (DMMP) in different solvents including methanol, deuterated methanol (methanol-D4), pure water, and deuterium oxide (water-D2), it was concluded that the water molecule in the air provides the hydrogen ion (H+) needed for ionization. The product ion spectra and the collision-induced dissociation processes of protonated molecules of nerve agent simulants, including DMMP, diethyl methanephosphonate (DEMP), trimethyl phosphate (TMP), triethyl phosphate (TEP), tripropyl phosphate (TPP), and tributyl phosphate (TBP) were analyzed. Results revealed that H+ mostly combined with phosphorus oxygen double bond (P = O) in the low-temperature plasma ionization. By analyzing the peak intensity distribution of product ions of protonated molecules, the presence of proton and charge migration in the low temperature plasma ionization and collision-induced dissociation were researched. This study could provide technical guidance for the rapid and accurate detection of chemical warfare agents through low temperature plasma ionization-mass spectrometry.
Collapse
Affiliation(s)
- Baoqiang Li
- State Key Laboratory of NBC Protection for Civilian, Beijing, China
| | - Jinglin Kong
- State Key Laboratory of NBC Protection for Civilian, Beijing, China
| | - Lin Zhang
- State Key Laboratory of NBC Protection for Civilian, Beijing, China
| | - Wenxiang Fu
- State Key Laboratory of NBC Protection for Civilian, Beijing, China
| | - Zhongyao Zhang
- State Key Laboratory of NBC Protection for Civilian, Beijing, China
| | - Cuiping Li
- State Key Laboratory of NBC Protection for Civilian, Beijing, China
| |
Collapse
|
4
|
Chen J, Yan M, Tang Y, Yu J, Xu W, Fu Y, Cao H, He Q, Cheng J. Rational Construction of Highly Tunable Organic Charge-Transfer Complexes for Chemiresistive Sensor Applications. ACS APPLIED BIO MATERIALS 2019; 2:3678-3685. [DOI: 10.1021/acsabm.9b00557] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Jinming Chen
- State Key Lab of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Changning Road 865, Shanghai 200050, China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Yuquan Road, Beijing 100049, China
| | - Mingzhu Yan
- State Key Lab of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Changning Road 865, Shanghai 200050, China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Yuquan Road, Beijing 100049, China
| | - Yilong Tang
- State Key Lab of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Changning Road 865, Shanghai 200050, China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Yuquan Road, Beijing 100049, China
| | - Jinping Yu
- ShanghaiTech University, 393 Middle Huaxia Road, Pudong, Shanghai 201210, China
| | - Wei Xu
- State Key Lab of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Changning Road 865, Shanghai 200050, China
| | - Yanyan Fu
- State Key Lab of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Changning Road 865, Shanghai 200050, China
| | - Huimin Cao
- State Key Lab of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Changning Road 865, Shanghai 200050, China
| | - Qingguo He
- State Key Lab of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Changning Road 865, Shanghai 200050, China
| | - Jiangong Cheng
- State Key Lab of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Changning Road 865, Shanghai 200050, China
| |
Collapse
|