1
|
Radić J, Perović D, Gričar E, Kolar M. Potentiometric Determination of Maprotiline Hydrochloride in Pharmaceutical and Biological Matrices Using a Novel Modified Carbon Paste Electrode. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22239201. [PMID: 36501902 PMCID: PMC9739387 DOI: 10.3390/s22239201] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 11/23/2022] [Accepted: 11/24/2022] [Indexed: 06/12/2023]
Abstract
Potentiometry with membrane selective electrodes is preferable for measuring the various constituents of pharmaceuticals. In this work, carbon paste electrodes (CPE) were prepared, modified, and tested for the determination of maprotiline hydrochloride, which acts as an antidepressant. The proposed CPE was based on an ionic association complex of maprotiline-tetraphenylborate, 2-nitrophenyloctyl as a binder, and sodium tetraphenylborate as an ionic lipophilic additive. The optimized composition improved potentiometric properties up to theoretical Nernst response values of -59.5 ± 0.8 mV dec-1, in the concentration range of maprotiline from 1.6 × 10-7 to 1.0 × 10-2 mol L-1, and a detection limit of 1.1 × 10-7 mol L-1. The CPE provides excellent reversibility and reproducibility, exhibits a fast response time, and is applicable over a wide pH range. No significant effect was observed in several interfering species tested. The proposed electrode was used for the precise determination of maprotiline in pure solutions, urine samples, and a real sample-the drug Ludiomil.
Collapse
Affiliation(s)
- Josip Radić
- Department of Environmental Chemistry, Faculty of Chemistry and Technology, University of Split, R. Boškovića 35, 21000 Split, Croatia
| | - Dorotea Perović
- Department of Environmental Chemistry, Faculty of Chemistry and Technology, University of Split, R. Boškovića 35, 21000 Split, Croatia
| | - Ema Gričar
- Department of Chemistry and Biochemistry, Faculty of Chemistry and Chemical Technology, University of Ljubljana, Večna pot 113, 1000 Ljubljana, Slovenia
| | - Mitja Kolar
- Department of Chemistry and Biochemistry, Faculty of Chemistry and Chemical Technology, University of Ljubljana, Večna pot 113, 1000 Ljubljana, Slovenia
| |
Collapse
|
2
|
The use of nanocomposite approach in the construction of carbon paste electrode and its application for the potentiometric determination of iodide. MONATSHEFTE FUR CHEMIE 2022. [DOI: 10.1007/s00706-022-02973-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
|
3
|
Büyüktiryaki S, Yazıcı B, Ersöz A, Say R, Özkütük EB. Application of HRP-streptavidin bionanoparticles for potentiometric biotin determination. Bioelectrochemistry 2022; 144:107993. [PMID: 34823072 DOI: 10.1016/j.bioelechem.2021.107993] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Revised: 10/15/2021] [Accepted: 11/02/2021] [Indexed: 01/02/2023]
Abstract
Biotin is widely used in infant formula to prevent biotin deficiency of newborn babies and in beauty products as nutritional supplements for coenzymatic functions and having strong nails, shiny hair, and skin over the last few years. There is a need for the development of a fast, simple and reusable assay method to perform biotin determination at very low concentrations. Biotin determination has achieved with a prepared potentiometric biotin sensor that has a very wide concentration range (10-15M-10-7M) and a lower detection limit (0.3 10-15M) with a very good regression coefficient (0.9925). A quick response (7 min), good accuracy (recovery 100.4-103.7%), reproducible, reusable (10 times), and long-term stability (3 months) have been obtained using the prepared potentiometric sensor. The obtained results have proved that the prepared potentiometric sensor can be used for biotin determination in real samples.
Collapse
Affiliation(s)
- Sibel Büyüktiryaki
- Department of Medical Services and Techniques, Yunus Emre Vocational School of Health Services, Anadolu University, Eskişehir, TR 26470, Turkey.
| | - Burcu Yazıcı
- Department of Chemistry, Faculty of Science and Letters, Eskişehir Osmangazi University, Eskisehir, TR 26480, Turkey
| | - Arzu Ersöz
- Bionkit Co Ltd., Anadolu University Teknopark, Eskisehir, TR 26470, Turkey; Department of Chemistry, Eskişehir Technical University, Eskisehir, TR 26470, Turkey
| | - Rıdvan Say
- Bionkit Co Ltd., Anadolu University Teknopark, Eskisehir, TR 26470, Turkey
| | - Ebru Birlik Özkütük
- Department of Chemistry, Faculty of Science and Letters, Eskişehir Osmangazi University, Eskisehir, TR 26480, Turkey
| |
Collapse
|
4
|
Hussien E, Rizk M, Daoud A, El-Eryan R. An Eco‐Friendly pencil graphite sensor for Voltammetric Analysis of the antidepressant Vilazodone Hydrochloride. ELECTROANAL 2022. [DOI: 10.1002/elan.202100457] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Emad Hussien
- National Organization for Drug Control and Research EGYPT
| | | | - Amira Daoud
- National Organization for Drug Control and Research EGYPT
| | | |
Collapse
|
5
|
Gričar E, Kalcher K, Genorio B, Kolar M. Highly Sensitive Amperometric Detection of Hydrogen Peroxide in Saliva Based on N-Doped Graphene Nanoribbons and MnO 2 Modified Carbon Paste Electrodes. SENSORS 2021; 21:s21248301. [PMID: 34960395 PMCID: PMC8707399 DOI: 10.3390/s21248301] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 12/06/2021] [Accepted: 12/10/2021] [Indexed: 11/27/2022]
Abstract
Four different graphene-based nanomaterials (htGO, N-htGO, htGONR, and N-htGONR) were synthesized, characterized, and used as a modifier of carbon paste electrode (CPE) in order to produce a reliable, precise, and highly sensitive non-enzymatic amperometric hydrogen peroxide sensor for complex matrices. CPE, with their robustness, reliability, and ease of modification, present a convenient starting point for the development of new sensors. Modification of CPE was optimized by systematically changing the type and concentration of materials in the modifier and studying the prepared electrode surface by cyclic voltammetry. N-htGONR in combination with manganese dioxide (1:1 ratio) proved to be the most appropriate material for detection of hydrogen peroxide in pharmaceutical and saliva matrices. The developed sensor exhibited a wide linear range (1.0–300 µM) and an excellent limit of detection (0.08 µM) and reproducibility, as well as high sensitivity and stability. The sensor was successfully applied to real sample analysis, where the recovery values for a commercially obtained pharmaceutical product were between 94.3% and 98.0%. Saliva samples of a user of the pharmaceutical product were also successfully analyzed.
Collapse
Affiliation(s)
- Ema Gričar
- Department of Chemistry and Biochemistry, Faculty of Chemistry and Chemical Technology, University of Ljubljana, Večna pot 113, 1000 Ljubljana, Slovenia;
| | - Kurt Kalcher
- Department of Analytical Chemistry, Insistute of Chemistry, University of Graz, Universitätsplatz 1, 8020 Graz, Austria;
| | - Boštjan Genorio
- Department of Chemical Engineering and Technical Safety, Faculty of Chemistry and Chemical Technology, University of Ljubljana, Večna pot 113, 1000 Ljubljana, Slovenia
- Correspondence: (B.G.); (M.K.)
| | - Mitja Kolar
- Department of Chemistry and Biochemistry, Faculty of Chemistry and Chemical Technology, University of Ljubljana, Večna pot 113, 1000 Ljubljana, Slovenia;
- Correspondence: (B.G.); (M.K.)
| |
Collapse
|
6
|
Mahmoud Mostafa S, Ali Farghali A, Magdy Khalil M. Novel Zn‐Fe LDH/MWCNT
s
and Graphene/MWCNTs Nanocomposites Based Potentiometric Sensors for Benzydamine Determination in Biological Fluids and Real Water Samples. ELECTROANAL 2021. [DOI: 10.1002/elan.202060455] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
| | - Ahmed Ali Farghali
- Materials Science and Nanotechnology Department Faculty of Postgraduate Studies for Advanced Sciences Beni-Suef University Beni-Suef Egypt
| | | |
Collapse
|
7
|
Trabik YA, Al‐Afify NKH, El‐Kosasy AM, Magdy N. Application of Precipitation‐based and Nanoparticle‐based Techniques for Fabrication of Potentiometric Sensors for Nano Molar Determination of Chitosan and Polyvinyl Pyrrolidone in Pharmaceutical Formulations and Biological Fluids. ELECTROANAL 2021. [DOI: 10.1002/elan.202060492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Yossra A. Trabik
- Department of Pharmaceutical Analytical Chemistry Faculty of Pharmacy Ain Shams University Cairo Egypt
| | - Nourhan KH. Al‐Afify
- Department of Pharmaceutical Analytical Chemistry Faculty of Pharmacy Ain Shams University Cairo Egypt
| | - Amira M. El‐Kosasy
- Department of Pharmaceutical Analytical Chemistry Faculty of Pharmacy Ain Shams University Cairo Egypt
| | - N. Magdy
- Department of Pharmaceutical Analytical Chemistry Faculty of Pharmacy Ain Shams University Cairo Egypt
| |
Collapse
|
8
|
A Novel Reduced Graphene Oxide Modified Carbon Paste Electrode for Potentiometric Determination of Trihexyphenidyl Hydrochloride in Pharmaceutical and Biological Matrices. SENSORS 2021; 21:s21092955. [PMID: 33922519 PMCID: PMC8122888 DOI: 10.3390/s21092955] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 04/16/2021] [Accepted: 04/19/2021] [Indexed: 12/02/2022]
Abstract
A novel promising carbon paste electrode with excellent potentiometric properties was prepared for the analysis of trihexyphenidyl hydrochloride (THP), the acetylcholine receptor and an anticholinergic drug in real samples. It contains 10.2% trihexyphenidy-tetraphenylborate ionic pair as the electroactive material, with the addition of 3.9% reduced graphene oxide and 0.3% of anionic additive into the paste, which consists of 45.0% dibutylphthalate as the solvent mediator and 40.6% graphite. Under the optimized experimental conditions, the electrode showed a Nernstian slope of 58.9 ± 0.2 mV/decade with a regression coefficient of 0.9992. It exhibited high selectivity and reproducibility as well as a fast and linear dynamic response range from 4.0 × 10−7 to 1.0 × 10−2 M. The electrode remained usable for up to 19 days. Analytical applications showed excellent recoveries ranging from 96.8 to 101.7%, LOD was 2.5 × 10−7 M. The electrode was successfully used for THP analysis of pharmaceutical and biological samples.
Collapse
|
9
|
Mohamed GG, Fekry AM, Attia FMA, Ibrahim NS, Azab SM. Simultaneous determination of some antidepressant drugs and vitamin B12 in pharmaceutical products and urine sample using HPLC method. J Chromatogr B Analyt Technol Biomed Life Sci 2020; 1150:122178. [DOI: 10.1016/j.jchromb.2020.122178] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2020] [Revised: 04/29/2020] [Accepted: 05/15/2020] [Indexed: 10/24/2022]
|
10
|
Khalil MM, Farghali AA, El Rouby WMA, Abd-Elgawad IH. Preparation and characterization of novel MWCNTs/Fe-Co doped TNTs nanocomposite for potentiometric determination of sulpiride in real water samples. Sci Rep 2020; 10:8607. [PMID: 32451406 PMCID: PMC7248080 DOI: 10.1038/s41598-020-65592-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Accepted: 04/29/2020] [Indexed: 11/26/2022] Open
Abstract
Novel multiwalled carbon nanotubes/ Fe-Co doped titanate nanotubes nanocomposite (MWCNTs/Fe-Co doped TNTs) facilitated the charge transfer and enhanced sensitivity and selectivity. Herein, three novel modified carbon paste sensors (CPSs) based on MWCNTs (sensor I), Fe-Co doped TNTs (sensor II) and MWCNTs/Fe-Co doped TNTs composite (sensor III) were fabricated for a simple, low cost and high accuracy electrochemical method for the potentiometric determination of sulpiride (SLP). The sensors exhibited excellent Nernstian slopes 57.1 ± 0.4, 56 ± 0.5 and 58.8 ± 0.2 mV decade−1 with detection limits (DL) 7.6 × 10−7, 1.58 × 10−6 and 8.7 × 10−8 mol L−1, quantification limits (QL) 2.5 × 10−6, 5.2 × 10−6 and 2.9 × 10−7 mol L−1 for a long lifetime 20, 18, and 25 weeks for sensors (I), (II), and (III), respectively. The modified sensor (III) was applicable by measuring the concentration of spiked SLP in pure solutions, pharmaceutical products, human urine, and real water samples. The proposed method can be used as an important analytical tool in the quality control of the pharmaceutical industry.
Collapse
Affiliation(s)
- M M Khalil
- Chemistry Department, Faculty of Science, Beni-Suef University, Beni-Suef, Egypt.
| | - A A Farghali
- Materials Science and Nanotechnology Department, Faculty of Postgraduate Studies for Advanced Science, Beni-Suef University, Beni-Suef, Egypt
| | - Waleed M A El Rouby
- Materials Science and Nanotechnology Department, Faculty of Postgraduate Studies for Advanced Science, Beni-Suef University, Beni-Suef, Egypt
| | - I H Abd-Elgawad
- Chemistry Department, Faculty of Science, Beni-Suef University, Beni-Suef, Egypt
| |
Collapse
|
11
|
Noor Azam NF, Mohammad NA, Lim SA, Ahmed MU. A Label-free Cardiac Troponin T Electrochemiluminescence Immunosensor Enhanced by Graphene Nanoplatelets. ANAL SCI 2019; 35:973-978. [PMID: 31080197 DOI: 10.2116/analsci.19p105] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
In this study, a direct and label-free immunosensor was designed and constructed by modifying the screen-printed electrode with graphene nanoplatelets (GNPs) for the detection of the cardiac troponin T (cTnT). Firstly, GNPs were drop-casted onto carbon working electrode. Monoclonal cTnT antibodies were then immobilized on the GNPs via physical adsorption; finally, BSA was introduced to block non-specific binding sites. The detection of cTnT was performed using an electrochemiluminescence (ECL) technique with tris(bipyridine)ruthenium(II) chloride ([Ru(bpy)3]Cl2) used as a luminophore and TPrA (tripropylamine) as a co-reactant. The ECL intensity was demonstrated to be directly proportional to the cTnT concentration where a linear range from 100 pg mL-1 to 5 fg mL-1 of the cTnT detection was established. An extremely low limit of detection was achieved to be 0.05 fg mL-1 with an outstanding specificity. Additionally, this immunosensor showed excellent percentage recovery for real samples analyses in artificially spiked human serum.
Collapse
Affiliation(s)
- Nura Fazira Noor Azam
- Biosensors and Biotechnology Laboratory, Chemical Science Programme, Faculty of Science Universiti Brunei Darussalam
| | - Nur Afina Mohammad
- Biosensors and Biotechnology Laboratory, Chemical Science Programme, Faculty of Science Universiti Brunei Darussalam
| | | | - Minhaz Uddin Ahmed
- Biosensors and Biotechnology Laboratory, Chemical Science Programme, Faculty of Science Universiti Brunei Darussalam
| |
Collapse
|
12
|
Fekry AM, Mohamed GG, Abou Attia FM, Ibrahim NS, Azab SM. A nanoparticle modified carbon paste sensor for electrochemical determination of the antidepressant agent vilazodone. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.113305] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|