1
|
Yang S, Du J, Wei M, Huang Y, Zhang Y, Wang Y, Li J, Wei W, Qiao Y, Dong H, Zhang X. Colorimetric-photothermal-magnetic three-in-one lateral flow immunoassay for two formats of biogenic amines sensitive and reliable quantification. Anal Chim Acta 2023; 1239:340660. [PMID: 36628753 DOI: 10.1016/j.aca.2022.340660] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Revised: 11/18/2022] [Accepted: 11/22/2022] [Indexed: 11/29/2022]
Abstract
Rapid, simple, sensitive and reliable approaches for biogenic amines quantification in various food samples are essential to food safety. Lateral flow immunoassay (LFIA) has been wildly utilized in point-of-care testing (POCT) owing to its advantage of flexibility and feasibility. Here, we reported a Fe3O4@Au nanoparticles (NPs) (Fe3O4@AuNPs) based multimodal readout LFIA for rapid putrescine (Put) and histamine (His) quantification with a LOD down to 10 and 10 ng/mL in naked eye mode, 2.31 and 4.39 ng/mL in photothermal mode, 0.17 and 0.31 ng/mL in magnetic mode, respectively. Such multi-mode assay has been successfully used to detect Biogenic amines (BAs) in raw aquatic foods, including fish, prawns, beef, and pork, with overall recoveries ranging from 93.68 to 109.34%. Meanwhile, it is easily expanded to detect other typical BAs with high sensitivity by simply replacing antibodies. In view of the multi-signal reading, two quantitative formats, and high sensitivity, it may greatly widen the application of lateral flow detection in food safety.
Collapse
Affiliation(s)
- Shuangshuang Yang
- Beijing Key Laboratory for Bioengineering and Sensing Technology, Department of Chemistry & Biological Engineering, University of Science & Technology Beijing, Beijing, 100083, PR China; Marshall Laboratory of Biomedical Engineering, Research Center for Biosensor and Nanotheranostic, School of Biomedical Engineering, Health Science Center, Shenzhen University, Guangdong, 518060, PR China
| | - Jinya Du
- Beijing Key Laboratory for Bioengineering and Sensing Technology, Department of Chemistry & Biological Engineering, University of Science & Technology Beijing, Beijing, 100083, PR China
| | - Menglian Wei
- Marshall Laboratory of Biomedical Engineering, Research Center for Biosensor and Nanotheranostic, School of Biomedical Engineering, Health Science Center, Shenzhen University, Guangdong, 518060, PR China
| | - Yan Huang
- Beijing Key Laboratory for Bioengineering and Sensing Technology, Department of Chemistry & Biological Engineering, University of Science & Technology Beijing, Beijing, 100083, PR China
| | - Yufan Zhang
- Beijing Key Laboratory for Bioengineering and Sensing Technology, Department of Chemistry & Biological Engineering, University of Science & Technology Beijing, Beijing, 100083, PR China
| | - Yeyu Wang
- Beijing Key Laboratory for Bioengineering and Sensing Technology, Department of Chemistry & Biological Engineering, University of Science & Technology Beijing, Beijing, 100083, PR China
| | - Jinze Li
- Beijing Key Laboratory for Bioengineering and Sensing Technology, Department of Chemistry & Biological Engineering, University of Science & Technology Beijing, Beijing, 100083, PR China
| | - Wei Wei
- Beijing Key Laboratory for Bioengineering and Sensing Technology, Department of Chemistry & Biological Engineering, University of Science & Technology Beijing, Beijing, 100083, PR China
| | - Yuchun Qiao
- Beijing Key Laboratory for Bioengineering and Sensing Technology, Department of Chemistry & Biological Engineering, University of Science & Technology Beijing, Beijing, 100083, PR China
| | - Haifeng Dong
- Marshall Laboratory of Biomedical Engineering, Research Center for Biosensor and Nanotheranostic, School of Biomedical Engineering, Health Science Center, Shenzhen University, Guangdong, 518060, PR China.
| | - Xueji Zhang
- Marshall Laboratory of Biomedical Engineering, Research Center for Biosensor and Nanotheranostic, School of Biomedical Engineering, Health Science Center, Shenzhen University, Guangdong, 518060, PR China.
| |
Collapse
|
2
|
Vaas APJP, Yu RB, Quirino JP. In-line sample concentration in capillary electrophoresis by cyclodextrin to admicelle microextraction. Anal Bioanal Chem 2022; 414:6671-6680. [PMID: 35978220 PMCID: PMC9411250 DOI: 10.1007/s00216-022-04230-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 07/08/2022] [Accepted: 07/13/2022] [Indexed: 11/25/2022]
Abstract
Cyclodextrins (CDs) as a pseudophase in pseudophase-to-pseudophase microextraction (P2ME) in capillary zone electrophoresis (CZE) are proposed. In this P2ME mode called CD to admicelle ME, a long plug of dilute analyte solution prepared in cetyltrimethylammonium bromide (CTAB) at the critical micellar concentration was injected into the capillary. This formed CTAB admicelles at the interface between the solution and the negatively charged capillary surface, where the analytes were trapped. The injection of CD solution released the admicelles and the analytes from the capillary surface due to the formation of stable CD/CTAB inclusion complexes. The analytes are concentrated at the CD front during injection and voltage separation. Various neutral CDs were found to be effective for CD to admicelle ME. To implement this in-line sample concentration technique in CZE, CD concentration, sample injection time, and sample:CD solution injection ratio were optimized. The optimized conditions for five model anionic analytes, namely, 4-bromophenol, sulindac, sulfamethizole, 4-vinylbenzoic acid, and succinylsulfathiazole, were 20 mM α-CD in 20 mM sodium tetraborate (pH 9.2) solution, sample injection time of 370 s, and CD:sample injection ratio of 1:2. The sensitivity enhancement factors (SEFs) were between 112 and 168. The SEFs of sulindac and sulfamethizole in particular were similar to previously published off-line microextraction techniques, which are typically time-consuming. The calculated values of LOQ, intra-/inter-day (n = 6/n = 10, 3 days) repeatability, and linearity (R2) of CD to admicelle ME were 0.0125-0.05 µg/mL, 1.5-4.6%, 1.8-4.8%, and ≥0.999, respectively. Finally, the potential of CD to admicelle ME to the analysis of artificial urine samples was demonstrated.
Collapse
Affiliation(s)
- Andaravaas Patabadige Jude P Vaas
- Australian Centre for Research On Separation Science (ACROSS), School of Natural Sciences-Chemistry, University of Tasmania, Private Bag 75, Hobart, TAS, 7001, Australia
| | - Raymond B Yu
- Australian Centre for Research On Separation Science (ACROSS), School of Natural Sciences-Chemistry, University of Tasmania, Private Bag 75, Hobart, TAS, 7001, Australia
- Department of Pharmaceutical Chemistry, College of Pharmacy, University of the Philippines Manila, Manila, Philippines
| | - Joselito P Quirino
- Australian Centre for Research On Separation Science (ACROSS), School of Natural Sciences-Chemistry, University of Tasmania, Private Bag 75, Hobart, TAS, 7001, Australia.
| |
Collapse
|
3
|
Quantum Dots and Double Surfactant-Co-modified Electromembrane Extraction of Polar Aliphatic Bioamines in Water Samples Followed by Capillary Electrophoresis with Contactless Conductivity Detection. FOOD ANAL METHOD 2022. [DOI: 10.1007/s12161-022-02309-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
4
|
Wang M, Chen Z, Jing X, Zhou H, Wang Y, Ye J, Chu Q. Tween 20-capped gold nanoparticles for selective extraction of free low-molecular-weight thiols in saliva followed by capillary electrophoresis with contactless conductivity detection. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1176:122756. [PMID: 34022759 DOI: 10.1016/j.jchromb.2021.122756] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 04/22/2021] [Accepted: 05/02/2021] [Indexed: 11/29/2022]
Abstract
Low-molecular-weight thiols are widely present in human fluids, and are regarded as a kind of potential broad-spectrum evaluation indicators for some clinical diseases. In this work, gold nanoparticles capped with Tween 20 were used for purification and microextraction of the main free thiols (cysteine, homocysteine, glutathione and methionine) in saliva based on Au-S bond formation. Ultrasound further sped up the releasing of the target analytes, and the releasing time needed was only 10 min, and the required sample volume was only 40 µL. The desorption solution could be directly injected for electrophoretic analysis without derivatization, and field-amplified sample stacking of electrophoretic online enrichment technology further improved the detection sensitivity. The synergistic enrichment effect made the enrichment factors of four analytes reach 1119-2067 times. This developed method was applied for the analyses of saliva samples of healthy volunteers. Acceptable sensitivity (LODs: 0.15-1.5 ng mL-1) and recoveries (97.6-116%) were obtained in the saliva sample matrix. This proposed method provides an alternative for the sensitive detection of low-molecular-weight thiols in noninvasive body fluids, which has potential application prospect in the preliminary noninvasive diagnosis of diabetes, cardiovascular diseases, etc.
Collapse
Affiliation(s)
- Manman Wang
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai 200241, China
| | - Zheyan Chen
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai 200241, China
| | - Xiaofeng Jing
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai 200241, China
| | - Huan Zhou
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai 200241, China
| | - Ying Wang
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai 200241, China
| | - Jiannong Ye
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai 200241, China
| | - Qingcui Chu
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai 200241, China.
| |
Collapse
|
5
|
Hauser PC, Kubáň P. Capacitively coupled contactless conductivity detection for analytical techniques - Developments from 2018 to 2020. J Chromatogr A 2020; 1632:461616. [PMID: 33096295 DOI: 10.1016/j.chroma.2020.461616] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Revised: 10/09/2020] [Accepted: 10/10/2020] [Indexed: 12/20/2022]
Abstract
The developments of analytical contactless conductivity measurements based on capacitive coupling over the two years from mid-2018 to mid-2020 are covered. This mostly concerns applications of the technique in zone electrophoresis employing conventional capillaries and to a lesser extent lab-on-chip devices. However, its use for the detection in several other flow-based analytical methods has also been reported. Detection of bubbles and measurements of flow rates in two-phase flows are also recurring themes. A few new applications in stagnant aqueous samples, e.g. endpoint detection in titrations and measurement on paper-based devices, have been reported. Some variations of the design of the measuring cells and their read-out electronics have also been described.
Collapse
Affiliation(s)
- Peter C Hauser
- Department of Chemistry, University of Basel, Klingelbergstrasse 80, CH-4056, Basel, Switzerland.
| | - Pavel Kubáň
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200, Brno, Czech Republic.
| |
Collapse
|
6
|
Huang ZA, Scotland KB, Li Y, Tan J, Kung SHY, Chew BH, Chen DDY, Lange D. Determination of urinary prostaglandin E 2 as a potential biomarker of ureteral stent associated inflammation. J Chromatogr B Analyt Technol Biomed Life Sci 2020; 1145:122107. [PMID: 32315976 DOI: 10.1016/j.jchromb.2020.122107] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 04/04/2020] [Accepted: 04/04/2020] [Indexed: 12/21/2022]
Abstract
Ureteral stents are the most widely used surgical implant in urology. However, they may cause adverse effects to patients, including pain, discomfort, and inflammation. In this work, the inflammatory effect of stent placement and the associated elevation of cyclooxygenase-2 (COX-2) expression were observed. Furthermore, a capillary electrophoresis mass spectrometry (CE-MS) based approach was subsequently developed to quantify urinary prostaglandin E2 (PGE2), a COX-2 metabolite known to contribute to inflammatory renal diseases, to further interrogate the role of this pathway. Urine samples were cleaned and preconcentrated by solid-phase extraction (SPE), and an on-line sample stacking method was used for the enrichment of analytes. The accuracy, precision, and specificity of this method were validated. Standard addition methods were performed to assess the reliability of using deuterated internal standards (IS) in compensating the remaining matrix effect after SPE as well as the detector fluctuation. Through the analysis of 32 pig urine samples, a statistically significant increase of PGE2 was observed in the stented group compared to the unstented (P = 0.01) and the recovered (P = 0.004) groups. This work determined that stent placement may contribute to COX-2-dependent inflammation and developed a reliable CE-MS based methodology to quantify PGE2 in stented individuals that may further understand the biology of stent-associated inflammation and inform urologic patient management.
Collapse
Affiliation(s)
- Zi-Ao Huang
- Department of Chemistry, University of British Columbia, Vancouver, BC V6T 1Z1, Canada
| | - Kymora B Scotland
- Department of Urology, University of California Los Angeles, Los Angeles, CA 90024, USA.
| | - Yueyang Li
- Department of Chemistry, University of British Columbia, Vancouver, BC V6T 1Z1, Canada
| | - Jiahua Tan
- Department of Chemistry, University of British Columbia, Vancouver, BC V6T 1Z1, Canada
| | - Sonia H Y Kung
- Vancouver Prostate Center, Vancouver, BC V5Z 1M9, Canada
| | - Ben H Chew
- Department of Urologic Sciences, The Stone Centre at Vancouver General Hospital, University of British Columbia, Vancouver, BC V6H 3Z6, Canada
| | - David D Y Chen
- Department of Chemistry, University of British Columbia, Vancouver, BC V6T 1Z1, Canada.
| | - Dirk Lange
- Department of Urologic Sciences, The Stone Centre at Vancouver General Hospital, University of British Columbia, Vancouver, BC V6H 3Z6, Canada.
| |
Collapse
|
7
|
Guo M, Liu S, Wang M, Lv Y, Shi J, Zeng Y, Ye J, Chu Q. Double surfactants-assisted electromembrane extraction of cyromazine and melamine in surface water, soil and cucumber samples followed by capillary electrophoresis with contactless conductivity detection. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE 2020; 100:301-307. [PMID: 31525264 DOI: 10.1002/jsfa.10039] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Revised: 09/06/2019] [Accepted: 09/11/2019] [Indexed: 06/10/2023]
Abstract
BACKGROUND Cyromazine (CYR) and its main degradation product melamine (MEL) are attracting wide attention due to their potential hazards to the environment and humans. In this work, double surfactants-assisted electromembrane extraction (DS-EME) by Tween 20 and alkylated phosphate was firstly used for purification and extraction of CYR and MEL, and the extract was directly analyzed by capillary electrophoresis with capacitively coupled contactless conductivity detection. RESULTS Under the optimum conditions, two targets could be well separated from the main interferences, including common biogenic amines and inorganic cations within 14 min. This developed method was successfully applied to the analyses of surface water, soil and cucumber samples, and the average recoveries were in the range 93.3-112%. DS-EME provided a synergistic purification and enrichment effect for CYR and MEL by adding Tween 20 and alkylated phosphate into donor phase and supporting liquid membrane, respectively. Satisfactory limits of detection [0.2-1.5 ng mL-1 , signal-to-noise ratio (S/N) = 3] could be obtained in the tested sample matrices, and the corresponding enrichment factors were up to 115∼123 times. CONCLUSION This developed method provides an alternative for the simultaneous analysis of CYR and MEL in complex real-world samples. © 2019 Society of Chemical Industry.
Collapse
Affiliation(s)
- Mengnan Guo
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, China
| | - Shiyu Liu
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, China
| | - Manman Wang
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, China
| | - Yifei Lv
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, China
| | - Jialei Shi
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, China
| | - Yuan Zeng
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, China
| | | | - Qingcui Chu
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, China
| |
Collapse
|