1
|
Sato T, Haneishi K, Hisada H, Fujii MY, Koide T, Fukami T. Real-Time Quantitative Evaluation of a Drug during Liposome Preparation Using a Probe-Type Raman Spectrometer. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024; 40:7962-7973. [PMID: 38577710 DOI: 10.1021/acs.langmuir.3c03872] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/06/2024]
Abstract
During the manufacturing process of liposome formulations, it is considered difficult to evaluate their physicochemical properties and biological profiles due to the complexity of their structure and manufacturing process. Conventional quality evaluation is labor-intensive and time-consuming; therefore, there was a need to introduce a method that could perform in-line, real-time evaluation during the manufacturing process. In this study, Raman spectroscopy was used to monitor in real time the encapsulation of drugs into liposomes and the drug release, which are particularly important quality evaluation items. Furthermore, Raman spectroscopy combined with partial least-squares (PLS) analysis was used for quantitative drug evaluation to assess consistency with results from UV-visible spectrophotometry (UV), a common quantification method. The prepared various ciprofloxacin (CPFX) liposomes were placed in cellulose tubes, and a probe-type Raman spectrophotometer was used to monitor drug encapsulation, the removal of unencapsulated drug, and drug release characteristics in real time using a dialysis method. In the Raman spectra of the liposomes prepared by remote loading, the intensities of the CPFX-derived peaks increased upon drug encapsulation and showed a slight decrease upon removal of the unencapsulated drug. Furthermore, the peak intensity decreased more gradually during the drug release. In all Raman monitoring experiments, the discrepancy between quantified values of CPFX concentration in liposomes, as measured by Raman spectroscopy combined with partial least-squares (PLS) analysis, and those obtained through ultraviolet (UV) spectrophotometry was within 6.7%. The results revealed that the quantitative evaluation of drugs using a combination of Raman spectroscopy and PLS analysis was as accurate as the evaluation using UV spectrophotometry, which was used for comparison. These results indicate the promising potential of Raman spectroscopy as an innovative method for the quality evaluation of liposomal formulations.
Collapse
Affiliation(s)
- Takumi Sato
- Department of Molecular Pharmaceutics, Meiji Pharmaceutical University, 2-522-1 Noshio, Kiyose, Tokyo 204-8588, Japan
| | - Kazuki Haneishi
- Department of Molecular Pharmaceutics, Meiji Pharmaceutical University, 2-522-1 Noshio, Kiyose, Tokyo 204-8588, Japan
| | - Hiroshi Hisada
- Department of Molecular Pharmaceutics, Meiji Pharmaceutical University, 2-522-1 Noshio, Kiyose, Tokyo 204-8588, Japan
| | - Mika Yoshimura Fujii
- Department of Molecular Pharmaceutics, Meiji Pharmaceutical University, 2-522-1 Noshio, Kiyose, Tokyo 204-8588, Japan
| | - Tatsuo Koide
- National Institute of Health Sciences, 3-25-26 Tonomachi, Kawasaki-ku, Kawasaki, Kanagawa 210-9501, Japan
| | - Toshiro Fukami
- Department of Molecular Pharmaceutics, Meiji Pharmaceutical University, 2-522-1 Noshio, Kiyose, Tokyo 204-8588, Japan
| |
Collapse
|
2
|
Alaoui Mansouri M, Kharbach M, Bouklouze A. Current Applications of Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS) in Pharmaceutical Analysis: Review. J Pharm Sci 2024; 113:856-865. [PMID: 38072117 DOI: 10.1016/j.xphs.2023.12.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 12/04/2023] [Accepted: 12/04/2023] [Indexed: 12/22/2023]
Abstract
The present review encompasses various applications of multivariate curve resolution- alternating least squares (MCR-ALS) as a promising data handling, which is issued by analytical techniques in pharmaceutics. It involves different sections starting from a concise theory of MCR-ALS and four detailed applications in drugs analysis. Dissolution, stability, polymorphism, and quantification are the main four detailed applications. The data generated by analytical techniques associated with MCR-ALS deals accurately with different challenges compared to other chemometric tools. For each reviewed purpose, it was explained how MCR-ALS was applied and detailed information was given. Different approaches were introduced to overcome challenges that limit the use of MCR-ALS efficiently in pharmaceutical mixture were also discussed.
Collapse
Affiliation(s)
- Mohammed Alaoui Mansouri
- Nano and Molecular Systems Research Unit, University of Oulu, FI-90014 Oulu, Finland; University of Liege (ULiege), CIRM, Vibra-Santé HUB, Laboratory of Pharmaceutical Analytical Chemistry, CHU, B36, B-4000, Liege, Belgium.
| | - Mourad Kharbach
- Research Unit of Mathematical Sciences, University of Oulu, FI-90014 Oulu, Finland.
| | - Abdelaziz Bouklouze
- Bio-Pharmaceutical and Toxicological Analysis Research Team, Laboratory of Pharmacology and Toxicology, Faculty of Medicine and Pharmacy, University Mohammed V, Rabat, Morocco
| |
Collapse
|
3
|
Jeong H, Jeong S, Kim J, Chung H. An axially slanted illumination back-scattering Raman scheme for direct determination of component concentration of powder samples housed in a glass container. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2024; 308:123788. [PMID: 38142495 DOI: 10.1016/j.saa.2023.123788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Revised: 11/15/2023] [Accepted: 12/15/2023] [Indexed: 12/26/2023]
Abstract
For direct and non-sampling determination of the component concentration of a sample housed in a glass container, an axially slanted illumination (ASI) back-scattering Raman scheme that reduces glass background interference has been demonstrated. The strategy was to increase the distance between the spots illuminated by the laser on the glass container and the housed sample in back-scattering measurement. For realization, the laser initially illuminated at a slant through the upper side of the vial wall (sample-unoccupied space) and reach the top of the sample. By this way, fewer number of generated glass photons could be recognized by a detector since they are farther from the focal plane (sample-illumination spot). The concentration of rosuvastatin (2.98-4.14 wt%) in rosulord samples (mixed with five other excipients) was determined using the ASI back-scattering measurement. When the angle of illumination to the vertical axis was 30° and the distance from the center of the laser spot on the glass wall to the center of spot on the sample (DG-S) was 14.9 mm, the sample peaks became more apparent and characteristic due to the reduced glass background. The accuracy of the concentration measurement was superior to that obtained through conventional back-scattering, in which the DG-S was nearly zero. The proposed scheme provides a simple optical setting to suppress the glass background and takes advantage of the sensitivity of Raman analysis through back-scattering measurement, indicating it as an attractive option for through-container analysis.
Collapse
Affiliation(s)
- Haeseong Jeong
- Department of Chemistry and Research Institute for Convergence of Basic Science, Hanyang University, Seoul 04763, Republic of Korea
| | - Seoyeon Jeong
- Department of Chemistry and Research Institute for Convergence of Basic Science, Hanyang University, Seoul 04763, Republic of Korea
| | - Jaejin Kim
- Mokpo Marine Food-Industry Research Center, Mokpo-si, Jeollanam-do 58621, Republic of Korea.
| | - Hoeil Chung
- Department of Chemistry and Research Institute for Convergence of Basic Science, Hanyang University, Seoul 04763, Republic of Korea.
| |
Collapse
|
4
|
Mosca S, Lin Q, Stokes R, Bharucha T, Gangadharan B, Clarke R, Fernandez LG, Deats M, Walsby-Tickle J, Arman BY, Chunekar SR, Patil KD, Gairola S, Van Assche K, Dunachie S, Merchant HA, Kuwana R, Maes A, McCullagh J, Caillet C, Zitzmann N, Newton PN, Matousek P. Innovative method for rapid detection of falsified COVID-19 vaccines through unopened vials using handheld Spatially Offset Raman Spectroscopy (SORS). Vaccine 2023; 41:6960-6968. [PMID: 37865599 DOI: 10.1016/j.vaccine.2023.10.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 10/03/2023] [Accepted: 10/05/2023] [Indexed: 10/23/2023]
Abstract
Preventing, detecting, and responding to substandard and falsified vaccines is of critical importance for ensuring the safety, efficacy, and public trust in vaccines. This is of heightened importance in context of public health crisis, such as the COVID-19 pandemic, in which extreme world-wide shortages of vaccines provided a fertile ground for exploitation by falsifiers. Here, a proof-of-concept study explored the feasibility of using a handheld Spatially Offset Raman Spectroscopy (SORS) device to authenticate COVID-19 vaccines through rapid analysis of unopened vaccine vials. The results show that SORS can verify the chemical identity of dominant excipients non-invasively through vaccine vial walls. The ability of SORS to identify potentially falsified COVID-19 vaccines was demonstrated by measurement of surrogates for falsified vaccines contained in vaccine vials. In all cases studied, the SORS technique was able to differentiate between surrogate samples from the genuine COVISHIELD™ vaccine. The genuine vaccines tested included samples from six batches across two manufacturing sites to account for any potential variations between batches or manufacturing sites. Batch and manufacturing site variations were insignificant. In conjunction with existing security features, for example on labels and packaging, SORS provided an intrinsic molecular fingerprint of the dominant excipients of the vaccines. The technique could be extended to other COVID-19 and non-COVID-19 vaccines, as well as other liquid medicines. As handheld and portable SORS devices are commercially available and widely used for other purposes, such as airport security, they are rapidly deployable non-invasive screening tools for vaccine authentication.
Collapse
Affiliation(s)
- Sara Mosca
- Central Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory, UKRI, Harwell Campus, OX11 0QX, UK
| | - Qianqi Lin
- Central Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory, UKRI, Harwell Campus, OX11 0QX, UK
| | - Robert Stokes
- Agilent Technologies LDA UK, Becquerel Avenue, Didcot OX11 0RA, UK
| | - Tehmina Bharucha
- Department of Biochemistry, University of Oxford, Oxford OX1 3QU, UK; Kavli Institute for Nanoscience Discovery, University of Oxford, Oxford OX1 3QU, UK
| | - Bevin Gangadharan
- Department of Biochemistry, University of Oxford, Oxford OX1 3QU, UK; Kavli Institute for Nanoscience Discovery, University of Oxford, Oxford OX1 3QU, UK
| | - Rebecca Clarke
- Department of Chemistry, University of Oxford, Oxford OX1 3TA, UK
| | - Laura Gomez Fernandez
- Department of Biochemistry, University of Oxford, Oxford OX1 3QU, UK; Kavli Institute for Nanoscience Discovery, University of Oxford, Oxford OX1 3QU, UK
| | - Michael Deats
- Medicine Quality Research Group, NDM Centre for Global Health Research, Nuffield Department of Medicine, University of Oxford, Oxford OX3 7LG, UK; Mahidol-Oxford Tropical Medicine Research Unit, Faculty of Tropical Medicine, Mahidol University, Bangkok 10400, Thailand; Infectious Diseases Data Observatory, Centre of Tropical Medicine & Global Health, Nuffield Department of Medicine, University of Oxford, Oxford OX3 7LG, UK
| | | | - Benediktus Yohan Arman
- Department of Biochemistry, University of Oxford, Oxford OX1 3QU, UK; Kavli Institute for Nanoscience Discovery, University of Oxford, Oxford OX1 3QU, UK
| | | | - Kundan D Patil
- Serum Institute of India Pvt. Ltd., 212/2, Hadapsar, Pune 411028, India
| | - Sunil Gairola
- Serum Institute of India Pvt. Ltd., 212/2, Hadapsar, Pune 411028, India
| | - Kerlijn Van Assche
- Medicine Quality Research Group, NDM Centre for Global Health Research, Nuffield Department of Medicine, University of Oxford, Oxford OX3 7LG, UK; Mahidol-Oxford Tropical Medicine Research Unit, Faculty of Tropical Medicine, Mahidol University, Bangkok 10400, Thailand; Infectious Diseases Data Observatory, Centre of Tropical Medicine & Global Health, Nuffield Department of Medicine, University of Oxford, Oxford OX3 7LG, UK
| | - Susanna Dunachie
- Mahidol-Oxford Tropical Medicine Research Unit, Faculty of Tropical Medicine, Mahidol University, Bangkok 10400, Thailand; Department of Microbiology and Infectious Diseases, Oxford University Hospitals NHS Foundation Trust, Oxford OX3 9DU, UK; NIHR Oxford Biomedical Research Centre, Oxford University Hospitals NHS Foundation Trust, Oxford OX3 9DU, UK
| | - Hamid A Merchant
- Department of Pharmacy, School of Applied Sciences, University of Huddersfield, Queensgate, Huddersfield HD1 3DH, UK
| | - Rutendo Kuwana
- Regulation and Safety Unit, Regulation and Prequalification Department, Access to Medicines and Health Products Division, World Health Organization (WHO), Geneva, Switzerland
| | - Alexandrine Maes
- Regulation and Safety Unit, Regulation and Prequalification Department, Access to Medicines and Health Products Division, World Health Organization (WHO), Geneva, Switzerland
| | - James McCullagh
- Department of Chemistry, University of Oxford, Oxford OX1 3TA, UK
| | - Céline Caillet
- Medicine Quality Research Group, NDM Centre for Global Health Research, Nuffield Department of Medicine, University of Oxford, Oxford OX3 7LG, UK; Mahidol-Oxford Tropical Medicine Research Unit, Faculty of Tropical Medicine, Mahidol University, Bangkok 10400, Thailand; Infectious Diseases Data Observatory, Centre of Tropical Medicine & Global Health, Nuffield Department of Medicine, University of Oxford, Oxford OX3 7LG, UK
| | - Nicole Zitzmann
- Department of Biochemistry, University of Oxford, Oxford OX1 3QU, UK; Kavli Institute for Nanoscience Discovery, University of Oxford, Oxford OX1 3QU, UK
| | - Paul N Newton
- Medicine Quality Research Group, NDM Centre for Global Health Research, Nuffield Department of Medicine, University of Oxford, Oxford OX3 7LG, UK; Mahidol-Oxford Tropical Medicine Research Unit, Faculty of Tropical Medicine, Mahidol University, Bangkok 10400, Thailand; Infectious Diseases Data Observatory, Centre of Tropical Medicine & Global Health, Nuffield Department of Medicine, University of Oxford, Oxford OX3 7LG, UK.
| | - Pavel Matousek
- Central Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory, UKRI, Harwell Campus, OX11 0QX, UK; Medicine Quality Research Group, NDM Centre for Global Health Research, Nuffield Department of Medicine, University of Oxford, Oxford OX3 7LG, UK; Mahidol-Oxford Tropical Medicine Research Unit, Faculty of Tropical Medicine, Mahidol University, Bangkok 10400, Thailand; Infectious Diseases Data Observatory, Centre of Tropical Medicine & Global Health, Nuffield Department of Medicine, University of Oxford, Oxford OX3 7LG, UK.
| |
Collapse
|
5
|
Liu Z, Huang M, Zhu Q, Qin J, Kim MS. Evaluating performance of SORS-based subsurface signal separation methods using statistical replication Monte Carlo simulation. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 293:122520. [PMID: 36812758 DOI: 10.1016/j.saa.2023.122520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 02/10/2023] [Accepted: 02/16/2023] [Indexed: 06/18/2023]
Abstract
Spatially offset Raman spectroscopy (SORS) is a depth-profiling technique with deep information enhancement. However, the interference of the surface layer cannot be eliminated without prior information. The signal separation method is an effective candidate for reconstructing pure subsurface Raman spectra, and there is still a lack of evaluation means for the signal separation method. Therefore, a method based on line-scan SORS combined with improved statistical replication Monte Carlo (SRMC) simulation was proposed to evaluate the effectiveness of food subsurface signal separation method. Firstly, SRMC simulates the photon flux in the sample, generates a corresponding number of Raman photons at each voxel of interest, and collects them by external map scanning. Then, 5625 groups of mixed signals with different optical characteristic parameters were convoluted with spectra of public database and application measurement and introduced into signal separation methods. The effectiveness and application range of the method were evaluated by the similarity between the separated signals and the source Raman spectra. Finally, the simulation results were verified by three packaged foods. FastICA method can effectively separate Raman signals from subsurface layer of food and thus promote deep quality evaluation of food.
Collapse
Affiliation(s)
- Zhenfang Liu
- Key Laboratory of Advanced Process Control for Light Industry (Ministry of Education), Jiangnan University, Wuxi 214122, China
| | - Min Huang
- Key Laboratory of Advanced Process Control for Light Industry (Ministry of Education), Jiangnan University, Wuxi 214122, China.
| | - Qibing Zhu
- Key Laboratory of Advanced Process Control for Light Industry (Ministry of Education), Jiangnan University, Wuxi 214122, China
| | - Jianwei Qin
- USDA/ARS Environmental Microbial and Food Safety Laboratory, Beltsville Agricultural Research Center, Bldg., 303, BARC-East, 10300 Baltimore Ave., MD 20705-2350, USA
| | - Moon S Kim
- USDA/ARS Environmental Microbial and Food Safety Laboratory, Beltsville Agricultural Research Center, Bldg., 303, BARC-East, 10300 Baltimore Ave., MD 20705-2350, USA
| |
Collapse
|
6
|
Sun N, Chang L, Lu Y, Wu W. Raman Mapping-Based Reverse Engineering Facilitates Development of Sustained-Release Nifedipine Tablet. Pharmaceutics 2022; 14:pharmaceutics14051052. [PMID: 35631638 PMCID: PMC9147140 DOI: 10.3390/pharmaceutics14051052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2022] [Revised: 05/05/2022] [Accepted: 05/11/2022] [Indexed: 12/01/2022] Open
Abstract
The development of generic preparations that are bioequivalent to a reference listed drug (RLD) is faced with challenges because some critical attributes of RLDs are commonly unknown to developers. In order to determine these attributes, Raman mapping-based reverse engineering in this study to analyze a model sustained-release tablet of nifedipine. The Raman mapping results indicate that the size and size distribution of nifedipine are critical to its release pattern and bioavailability. The tablets with a particle size of nifedipine comparable to that of a commercial product, Adalat®-L, showed similar in vitro release profiles to the RLD. Moreover, a pharmacokinetic study in human volunteers proved the bioequivalence of the two preparations. In conclusion, Raman mapping-based reverse engineering has the potential to facilitate the development of generic preparations.
Collapse
Affiliation(s)
- Ningyun Sun
- Key Laboratory of Smart Drug Delivery of MOE, School of Pharmacy, Fudan University, Shanghai 201203, China;
- SPH Sine Pharmaceutical Laboratories Co., Ltd., Shanghai 201206, China;
| | - Liang Chang
- SPH Sine Pharmaceutical Laboratories Co., Ltd., Shanghai 201206, China;
| | - Yi Lu
- Key Laboratory of Smart Drug Delivery of MOE, School of Pharmacy, Fudan University, Shanghai 201203, China;
- Fudan Zhangjiang Institute, Shanghai 201203, China
- Correspondence: (Y.L.); (W.W.)
| | - Wei Wu
- Key Laboratory of Smart Drug Delivery of MOE, School of Pharmacy, Fudan University, Shanghai 201203, China;
- Fudan Zhangjiang Institute, Shanghai 201203, China
- Correspondence: (Y.L.); (W.W.)
| |
Collapse
|
7
|
Wulandari L, Idroes R, Noviandy TR, Indrayanto G. Application of chemometrics using direct spectroscopic methods as a QC tool in pharmaceutical industry and their validation. PROFILES OF DRUG SUBSTANCES, EXCIPIENTS, AND RELATED METHODOLOGY 2022; 47:327-379. [PMID: 35396015 DOI: 10.1016/bs.podrm.2021.10.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
This present review described the application of chemometrics using direct spectroscopic methods at the quality control (QC) laboratory of Pharmaceutical Industries. Using chemometrics methods, all QC assessments during the fabrication processes of the drug preparations can be well performed. Chemometrics methods have some advantages compared to the conventional methods, i.e., non-destructive, can be performed directly to intake samples without any extractions, unnecessary performing stability studies, and cost-effective. To achieve reliable results of analyses, all methods must be validated first prior to routine applications. According to the current Pharmacopeia, the validation parameters are specificity/selectivity, accuracy, repeatability, intermediate precision, range, detection limit, quantification limit and robustness. These validation data must meet the acceptance criteria, that have been described by the analytical target profile (ATP) of the drug preparations.
Collapse
Affiliation(s)
| | - Rinaldi Idroes
- Department of Pharmacy, Banda Aceh, Indonesia; Department of Chemistry, Faculty of Mathematics and Natural Sciences, Syiah Kuala University, Banda Aceh, Indonesia
| | - Teuku Rizky Noviandy
- Department of Informatics, Faculty of Mathematics and Natural Sciences, Syiah Kuala University, Banda Aceh, Indonesia
| | | |
Collapse
|
8
|
Trends in pharmaceutical analysis and quality control by modern Raman spectroscopic techniques. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116623] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
9
|
Cooman T, Trejos T, Romero AH, Arroyo LE. Implementing machine learning for the identification and classification of compound and mixtures in portable Raman instruments. Chem Phys Lett 2022. [DOI: 10.1016/j.cplett.2021.139283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
10
|
Dowek A, Berge M, Prognon P, Legrand FX, Larquet E, Tfayli A, Lê LMM, Caudron E. Discriminative and quantitative analysis of norepinephrine and epinephrine by surface-enhanced Raman spectroscopy with gold nanoparticle suspensions. Anal Bioanal Chem 2021; 414:1163-1176. [PMID: 34718838 DOI: 10.1007/s00216-021-03743-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2021] [Revised: 10/15/2021] [Accepted: 10/18/2021] [Indexed: 01/27/2023]
Abstract
Surface-enhanced Raman spectroscopy (SERS) is a powerful analytical technique capable of increasing the Raman signal of an analyte using specific nanostructures. The close contact between those nanostructures, usually a suspension of nanoparticles, and the molecule of interest produces an important exaltation of the intensity of the Raman signal. Even if the exaltation leads to an improvement of Raman spectroscopy sensitivity, the complexity of the SERS signal and the numbers of parameters to be controlled allow the use of SERS for detection rather than quantification. The aim of this study was to develop a robust discriminative and quantitative analysis in accordance with pharmaceutical standards. In this present work, we develop a discriminative and quantitative analysis based on the previous optimized parameters obtained by the design of experiments fixed for norepinephrine (NOR) and extended to epinephrine (EPI) which are two neurotransmitters with very similar structures. Studying the short evolution of the Raman signal intensity over time coupled with chemometric tools allowed the identification of outliers and their removal from the data set. The discriminant analysis showed an excellent separation of EPI and NOR. The comparative analysis of the data showed the superiority of the multivariate analysis after logarithmic transformation. The quantitative analysis allowed the development of robust quantification models from several gold nanoparticle batches with limits of quantification of 32 µg/mL for NOR and below 20 µg/mL for EPI even though no Raman signal is observable for such concentrations. This study improves SERS analysis over ultrasensitive detection for discrimination and quantification using a handheld Raman spectrometer.
Collapse
Affiliation(s)
- Antoine Dowek
- Service de Pharmacie, Hôpital européen Georges Pompidou, APHP.Centre Université-Paris, 20 rue Leblanc, 75015, Paris, France. .,Lipides, Systèmes Analytiques et Biologiques, Université Paris-Saclay, 92296, Châtenay-Malabry, France.
| | - Marion Berge
- Service de Pharmacie, Hôpital européen Georges Pompidou, APHP.Centre Université-Paris, 20 rue Leblanc, 75015, Paris, France.,Lipides, Systèmes Analytiques et Biologiques, Université Paris-Saclay, 92296, Châtenay-Malabry, France
| | - Patrice Prognon
- Service de Pharmacie, Hôpital européen Georges Pompidou, APHP.Centre Université-Paris, 20 rue Leblanc, 75015, Paris, France.,Lipides, Systèmes Analytiques et Biologiques, Université Paris-Saclay, 92296, Châtenay-Malabry, France
| | | | - Eric Larquet
- Laboratoire de Physique de la Matière Condensée (LPMC), Ecole Polytechnique, CNRS, Institut Polytechnique de Paris, 91128, Palaiseau, France
| | - Ali Tfayli
- Lipides, Systèmes Analytiques et Biologiques, Université Paris-Saclay, 92296, Châtenay-Malabry, France
| | - Laetitia Minh Mai Lê
- Service de Pharmacie, Hôpital européen Georges Pompidou, APHP.Centre Université-Paris, 20 rue Leblanc, 75015, Paris, France.,Lipides, Systèmes Analytiques et Biologiques, Université Paris-Saclay, 92296, Châtenay-Malabry, France
| | - Eric Caudron
- Service de Pharmacie, Hôpital européen Georges Pompidou, APHP.Centre Université-Paris, 20 rue Leblanc, 75015, Paris, France.,Lipides, Systèmes Analytiques et Biologiques, Université Paris-Saclay, 92296, Châtenay-Malabry, France
| |
Collapse
|
11
|
Elderderi S, Wils L, Leman-Loubière C, Byrne HJ, Chourpa I, Enguehard-Gueiffier C, Munnier E, Elbashir AA, Boudesocque-Delaye L, Bonnier F. In Situ Water Quantification in Natural Deep Eutectic Solvents Using Portable Raman Spectroscopy. Molecules 2021; 26:molecules26185488. [PMID: 34576961 PMCID: PMC8471915 DOI: 10.3390/molecules26185488] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 09/01/2021] [Accepted: 09/06/2021] [Indexed: 11/21/2022] Open
Abstract
Raman spectroscopy is a label-free, non-destructive, non-invasive analytical tool that provides insight into the molecular composition of samples with minimum or no sample preparation. The increased availability of commercial portable Raman devices presents a potentially easy and convenient analytical solution for day-to-day analysis in laboratories and production lines. However, their performance for highly specific and sensitive analysis applications has not been extensively evaluated. This study performs a direct comparison of such a commercially available, portable Raman system, with a research grade Raman microscope system for the analysis of water content of Natural Deep Eutectic Solvents (NADES). NADES are renewable, biodegradable and easily tunable “green” solvents, outcompeting existing organic solvents for applications in extraction from biomass, biocatalysis, and nanoparticle synthesis. Water content in NADES is, however, a critical parameter, affecting their properties, optimal use and extraction efficiency. In the present study, portable Raman spectroscopy coupled with Partial Least Squares Regression (PLSR) is investigated for rapid determination of water content in NADES samples in situ, i.e., directly in glassware. Three NADES systems, namely Betaine Glycerol (BG), Choline Chloride Glycerol (CCG) and Glucose Glycerol (GG), containing a range of water concentrations between 0% (w/w) and 28.5% (w/w), were studied. The results are directly compared with previously published studies of the same systems, using a research grade Raman microscope. PLSR results demonstrate the reliability of the analysis, surrendering R2 values above 0.99. Root Mean Square Errors Prediction (RMSEP) of 0.6805%, 0.9859% and 1.2907% w/w were found for respectively unknown CCG, BG and GG samples using the portable device compared to 0.4715%, 0.3437% and 0.7409% w/w previously obtained by analysis in quartz cuvettes with a Raman confocal microscope. Despite the relatively higher values of RMSEP observed, the comparison of the percentage of relative errors in the predicted concentration highlights that, overall, the portable device delivers accuracy below 5%. Ultimately, it has been demonstrated that portable Raman spectroscopy enables accurate quantification of water in NADES directly through glass vials without the requirement for sample withdrawal. Such compact instruments provide solvent and consumable free analysis for rapid analysis directly in laboratories and for non-expert users. Portable Raman is a promising approach for high throughput monitoring of water content in NADES that can support the development of new analytical protocols in the field of green chemistry in research and development laboratories but also in the industry as a routine quality control tool.
Collapse
Affiliation(s)
- Suha Elderderi
- EA 6295 Nanomédicaments et Nanosondes, Faculté de Pharmacie, Université de Tours, 31 Avenue Monge, 37200 Tours, France; (S.E.); (I.C.); (E.M.)
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Gezira, P.O. Box 20, Wad Madani 21111, Sudan
| | - Laura Wils
- EA 7502 Synthèse et Isolement de Molécules BioActives (SIMBA), Université de Tours, 31 Avenue Monge, 37200 Tours, France; (L.W.); (C.L.-L.); (C.E.-G.); (L.B.-D.)
| | - Charlotte Leman-Loubière
- EA 7502 Synthèse et Isolement de Molécules BioActives (SIMBA), Université de Tours, 31 Avenue Monge, 37200 Tours, France; (L.W.); (C.L.-L.); (C.E.-G.); (L.B.-D.)
| | - Hugh J. Byrne
- FOCAS Research Institute, TU Dublin-City Campus, Dublin 8, Ireland;
| | - Igor Chourpa
- EA 6295 Nanomédicaments et Nanosondes, Faculté de Pharmacie, Université de Tours, 31 Avenue Monge, 37200 Tours, France; (S.E.); (I.C.); (E.M.)
| | - Cécile Enguehard-Gueiffier
- EA 7502 Synthèse et Isolement de Molécules BioActives (SIMBA), Université de Tours, 31 Avenue Monge, 37200 Tours, France; (L.W.); (C.L.-L.); (C.E.-G.); (L.B.-D.)
| | - Emilie Munnier
- EA 6295 Nanomédicaments et Nanosondes, Faculté de Pharmacie, Université de Tours, 31 Avenue Monge, 37200 Tours, France; (S.E.); (I.C.); (E.M.)
| | - Abdalla A. Elbashir
- Department of Chemistry, Faculty of Science, University of Khartoum, P.O. Box 321, Khartoum 11115, Sudan;
- Department of Chemistry, College of Science, King Faisal University, P.O. Box 400, Al-Ahsa 31982, Saudi Arabia
| | - Leslie Boudesocque-Delaye
- EA 7502 Synthèse et Isolement de Molécules BioActives (SIMBA), Université de Tours, 31 Avenue Monge, 37200 Tours, France; (L.W.); (C.L.-L.); (C.E.-G.); (L.B.-D.)
| | - Franck Bonnier
- EA 6295 Nanomédicaments et Nanosondes, Faculté de Pharmacie, Université de Tours, 31 Avenue Monge, 37200 Tours, France; (S.E.); (I.C.); (E.M.)
- Correspondence:
| |
Collapse
|
12
|
Caillet C, Vickers S, Zambrzycki S, Fernández FM, Vidhamaly V, Boutsamay K, Boupha P, Peerawaranun P, Mukaka M, Newton PN. A comparative field evaluation of six medicine quality screening devices in Laos. PLoS Negl Trop Dis 2021; 15:e0009674. [PMID: 34591852 PMCID: PMC8483322 DOI: 10.1371/journal.pntd.0009674] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Accepted: 07/23/2021] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Medicine quality screening devices hold great promise for post-market surveillance (PMS). However, there is little independent evidence on their field utility and usability to inform policy decisions. This pilot study in the Lao PDR tested six devices' utility and usability in detecting substandard and falsified (SF) medicines. METHODOLOGY/PRINCIPAL FINDINGS Observational time and motion studies of the inspections by 16 Lao medicine inspectors of 1) the stock of an Evaluation Pharmacy (EP), constructed to resemble a Lao pharmacy, and 2) a sample set of medicines (SSM); were conducted without and with six devices: four handheld spectrometers (two near infrared: MicroPHAZIR RX, NIR-S-G1 & two Raman: Progeny, Truscan RM); one portable mid-infrared spectrometer (4500a), and single-use paper analytical devices (PAD). User experiences were documented by interviews and focus group discussions. Significantly more samples were wrongly categorised as pass/fail with the PAD compared to the other devices in EP inspections (p<0.05). The numbers of samples wrongly classified in EP inspections were significantly lower than in initial visual inspections without devices for 3/6 devices (NIR-S-G1, MicroPHAZIR RX, 4500a). The NIR-S-G1 had the fastest testing time per sample (median 93.5 sec, p<0.001). The time spent on EP visual inspection was significantly shorter when using a device than for inspections without devices, except with the 4500a, risking missing visual clues of samples being SF. The main user errors were the selection of wrong spectrometer reference libraries and wrong user interpretation of PAD results. Limitations included repeated inspections of the EP by the same inspectors with different devices and the small sample size of SF medicines. CONCLUSIONS/SIGNIFICANCE This pilot study suggests policy makers wishing to implement portable screening devices in PMS should be aware that overconfidence in devices may cause harm by reducing inspectors' investment in visual inspection. It also provides insight into the advantages/limitations of diverse screening devices in the hands of end-users.
Collapse
Affiliation(s)
- Céline Caillet
- Lao-Oxford-Mahosot Hospital-Wellcome Trust Research Unit, Microbiology Laboratory, Mahosot Hospital, Vientiane, Lao PDR
- Centre for Tropical Medicine and Global Health, Nuffield Department of Medicine, University of Oxford, Oxford, United Kingdom
- Infectious Diseases Data Observatory (IDDO)/WorldWide Antimalarial Resistance Network (WWARN), University of Oxford, Oxford, United Kingdom
- Mahidol Oxford Tropical Medicine Research Unit (MORU), Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand
| | - Serena Vickers
- Lao-Oxford-Mahosot Hospital-Wellcome Trust Research Unit, Microbiology Laboratory, Mahosot Hospital, Vientiane, Lao PDR
- Centre for Tropical Medicine and Global Health, Nuffield Department of Medicine, University of Oxford, Oxford, United Kingdom
- Infectious Diseases Data Observatory (IDDO)/WorldWide Antimalarial Resistance Network (WWARN), University of Oxford, Oxford, United Kingdom
| | - Stephen Zambrzycki
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia, United States of America
| | - Facundo M. Fernández
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia, United States of America
| | - Vayouly Vidhamaly
- Lao-Oxford-Mahosot Hospital-Wellcome Trust Research Unit, Microbiology Laboratory, Mahosot Hospital, Vientiane, Lao PDR
- Centre for Tropical Medicine and Global Health, Nuffield Department of Medicine, University of Oxford, Oxford, United Kingdom
- Infectious Diseases Data Observatory (IDDO)/WorldWide Antimalarial Resistance Network (WWARN), University of Oxford, Oxford, United Kingdom
| | - Kem Boutsamay
- Lao-Oxford-Mahosot Hospital-Wellcome Trust Research Unit, Microbiology Laboratory, Mahosot Hospital, Vientiane, Lao PDR
- Centre for Tropical Medicine and Global Health, Nuffield Department of Medicine, University of Oxford, Oxford, United Kingdom
- Infectious Diseases Data Observatory (IDDO)/WorldWide Antimalarial Resistance Network (WWARN), University of Oxford, Oxford, United Kingdom
| | - Phonepasith Boupha
- Lao-Oxford-Mahosot Hospital-Wellcome Trust Research Unit, Microbiology Laboratory, Mahosot Hospital, Vientiane, Lao PDR
- Centre for Tropical Medicine and Global Health, Nuffield Department of Medicine, University of Oxford, Oxford, United Kingdom
- Infectious Diseases Data Observatory (IDDO)/WorldWide Antimalarial Resistance Network (WWARN), University of Oxford, Oxford, United Kingdom
| | - Pimnara Peerawaranun
- Mahidol Oxford Tropical Medicine Research Unit (MORU), Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand
| | - Mavuto Mukaka
- Centre for Tropical Medicine and Global Health, Nuffield Department of Medicine, University of Oxford, Oxford, United Kingdom
- Mahidol Oxford Tropical Medicine Research Unit (MORU), Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand
| | - Paul N. Newton
- Lao-Oxford-Mahosot Hospital-Wellcome Trust Research Unit, Microbiology Laboratory, Mahosot Hospital, Vientiane, Lao PDR
- Centre for Tropical Medicine and Global Health, Nuffield Department of Medicine, University of Oxford, Oxford, United Kingdom
- Infectious Diseases Data Observatory (IDDO)/WorldWide Antimalarial Resistance Network (WWARN), University of Oxford, Oxford, United Kingdom
- Mahidol Oxford Tropical Medicine Research Unit (MORU), Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand
| |
Collapse
|
13
|
Caillet C, Vickers S, Vidhamaly V, Boutsamay K, Boupha P, Zambrzycki S, Luangasanatip N, Lubell Y, Fernández FM, Newton PN. Evaluation of portable devices for medicine quality screening: Lessons learnt, recommendations for implementation, and future priorities. PLoS Med 2021; 18:e1003747. [PMID: 34591861 PMCID: PMC8483386 DOI: 10.1371/journal.pmed.1003747] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Céline Caillet and co-authors discuss a Collection on use of portable devices for the evaluation of medicine quality and legitimacy.
Collapse
Affiliation(s)
- Céline Caillet
- Lao-Oxford-Mahosot Hospital-Wellcome Trust Research Unit, Microbiology Laboratory, Mahosot Hospital, Vientiane, Lao PDR
- Centre for Tropical Medicine and Global Health, Nuffield Department of Medicine, University of Oxford, Oxford, United Kingdom
- Infectious Diseases Data Observatory (IDDO)/WorldWide Antimalarial Resistance Network (WWARN), University of Oxford, Oxford, United Kingdom
| | - Serena Vickers
- Lao-Oxford-Mahosot Hospital-Wellcome Trust Research Unit, Microbiology Laboratory, Mahosot Hospital, Vientiane, Lao PDR
- Centre for Tropical Medicine and Global Health, Nuffield Department of Medicine, University of Oxford, Oxford, United Kingdom
- Infectious Diseases Data Observatory (IDDO)/WorldWide Antimalarial Resistance Network (WWARN), University of Oxford, Oxford, United Kingdom
| | - Vayouly Vidhamaly
- Lao-Oxford-Mahosot Hospital-Wellcome Trust Research Unit, Microbiology Laboratory, Mahosot Hospital, Vientiane, Lao PDR
- Centre for Tropical Medicine and Global Health, Nuffield Department of Medicine, University of Oxford, Oxford, United Kingdom
- Infectious Diseases Data Observatory (IDDO)/WorldWide Antimalarial Resistance Network (WWARN), University of Oxford, Oxford, United Kingdom
| | - Kem Boutsamay
- Lao-Oxford-Mahosot Hospital-Wellcome Trust Research Unit, Microbiology Laboratory, Mahosot Hospital, Vientiane, Lao PDR
- Centre for Tropical Medicine and Global Health, Nuffield Department of Medicine, University of Oxford, Oxford, United Kingdom
- Infectious Diseases Data Observatory (IDDO)/WorldWide Antimalarial Resistance Network (WWARN), University of Oxford, Oxford, United Kingdom
| | - Phonepasith Boupha
- Lao-Oxford-Mahosot Hospital-Wellcome Trust Research Unit, Microbiology Laboratory, Mahosot Hospital, Vientiane, Lao PDR
- Centre for Tropical Medicine and Global Health, Nuffield Department of Medicine, University of Oxford, Oxford, United Kingdom
- Infectious Diseases Data Observatory (IDDO)/WorldWide Antimalarial Resistance Network (WWARN), University of Oxford, Oxford, United Kingdom
| | - Stephen Zambrzycki
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia, United States of America
| | - Nantasit Luangasanatip
- Mahidol-Oxford Tropical Medicine Research Unit, Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand
| | - Yoel Lubell
- Centre for Tropical Medicine and Global Health, Nuffield Department of Medicine, University of Oxford, Oxford, United Kingdom
- Mahidol-Oxford Tropical Medicine Research Unit, Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand
| | - Facundo M. Fernández
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia, United States of America
| | - Paul N. Newton
- Lao-Oxford-Mahosot Hospital-Wellcome Trust Research Unit, Microbiology Laboratory, Mahosot Hospital, Vientiane, Lao PDR
- Centre for Tropical Medicine and Global Health, Nuffield Department of Medicine, University of Oxford, Oxford, United Kingdom
- Infectious Diseases Data Observatory (IDDO)/WorldWide Antimalarial Resistance Network (WWARN), University of Oxford, Oxford, United Kingdom
| |
Collapse
|
14
|
Arroyo-Cerezo A, Jimenez-Carvelo AM, González-Casado A, Koidis A, Cuadros-Rodríguez L. Deep (offset) non-invasive Raman spectroscopy for the evaluation of food and beverages – A review. Lebensm Wiss Technol 2021. [DOI: 10.1016/j.lwt.2021.111822] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
15
|
Lee Y, Kim J, Han J, Jeong H, Woo YA, Chung H. Axially slanted laser illumination scheme for direct and accurate Raman spectroscopic determination of gemcitabine concentration in freeze-dried gemcitabine injection powder housed in a glass container. Anal Chim Acta 2021; 1175:338746. [PMID: 34330445 DOI: 10.1016/j.aca.2021.338746] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Revised: 05/08/2021] [Accepted: 06/07/2021] [Indexed: 10/21/2022]
Abstract
When Raman spectroscopy is employed for a direct in situ determination of ingredient concentration for a product stored in a glass container, minimization of the interfering glass background in the collected spectrum is demanding to secure a more accurate analysis. To meet this request, an axially slanted illumination (ASI) scheme slantingly irradiating laser on the headspace side of a glass container and positioning a detector beneath the container was demonstrated in this study. This ASI scheme was basically designed to increase the distance between the laser illumination spot and detector location to minimize the number of glass photons reaching the detector. The analytical utility of the scheme was evaluated for the determination of gemcitabine concentration (42.9-58.2 wt%) in the gemcitabine injection powder housed in a glass container. Using the ASI scheme, the spectral features of the gemcitabine powder became distinct with only a weak underlying glass background signal. For comparative purpose, when an axially perpendicular offset (APO) scheme perpendicularly irradiating laser on the side wall where the sample was filled was used, the magnitude of glass background was higher, and the most intense gemcitabine peak was largely buried in the glass peak. The accuracy for determination of gemcitabine concentration using the ASI scheme was superior with an error of 0.20 wt%, while 0.33 wt% with employing the APO scheme. Overall, this study demonstrates that the ASI scheme is a potentially versatile Raman spectroscopic tool for fast non-sampling analysis of other products stored in a glass container.
Collapse
Affiliation(s)
- Yoonjeong Lee
- Department of Chemistry and Research Institute for Convergence of Basic Science, Hanyang University, Seoul, 04763, Republic of Korea
| | - Jaejin Kim
- Chong Kun Dang Pharmaceuticals, Chungcheongnam-do, 330-831, Republic of Korea
| | - Janghee Han
- Chong Kun Dang Pharmaceuticals, Chungcheongnam-do, 330-831, Republic of Korea
| | - Haeseong Jeong
- Department of Chemistry and Research Institute for Convergence of Basic Science, Hanyang University, Seoul, 04763, Republic of Korea
| | - Young-Ah Woo
- Chong Kun Dang Pharmaceuticals, Chungcheongnam-do, 330-831, Republic of Korea.
| | - Hoeil Chung
- Department of Chemistry and Research Institute for Convergence of Basic Science, Hanyang University, Seoul, 04763, Republic of Korea.
| |
Collapse
|
16
|
Elderderi S, Wils L, Leman-Loubière C, Henry S, Byrne HJ, Chourpa I, Munnier E, Elbashir AA, Boudesocque-Delaye L, Bonnier F. Comparison of Raman and attenuated total reflectance (ATR) infrared spectroscopy for water quantification in natural deep eutectic solvent. Anal Bioanal Chem 2021; 413:4785-4799. [PMID: 34061244 DOI: 10.1007/s00216-021-03432-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 05/19/2021] [Accepted: 05/25/2021] [Indexed: 01/31/2023]
Abstract
Natural deep eutectic solvents (NADES) are ionic solutions, of great interest for extraction from biomass, biocatalysis, and nanoparticle synthesis. They are easily synthesised and eco-friendly, have low volatility and high dissolution power, and are biodegradable. However, water content in NADES is a critical parameter, affecting their optimal use and extraction efficiency. Vibrational spectroscopic techniques are rapid, label-free, non-destructive, non-invasive, and cost-effective analytical tools that can probe the molecular composition of samples. A direct comparison between a previous study using attenuated total reflectance infrared (ATR-IR) spectroscopy for water quantification in NADES and the same investigation performed with Raman spectroscopy is presently reported. Three NADES systems, namely betaine-glycerol (BG), choline chloride-glycerol (CCG), and glucose-glycerol (GG), containing a range of water concentrations between 0% (w/w) and 40% (w/w), have been analysed with Raman spectroscopy coupled to partial least squares regression multivariate analysis. The values of root mean square error of cross-validation (RMSECV) obtained from analysis performed on the pre-processed spectra over the full spectral range (150-3750 cm-1) are respectively 0.2966% (w/w), 0.4703% (w/w), and 0.2351% (w/w) for BG, GG, and CCG. While the direct comparison to previous ATR-IR results shows essentially similar outcomes for BG, the RMSECV is 33.14% lower and 65.84% lower for CG and CCG. Furthermore, mean relative errors obtained with Raman spectroscopy, and calculated from a set of samples used as independent samples, were 1.452% (w/w), 1.175% (w/w), and 1.188% (w/w). Ultimately, Raman spectroscopy delivered performances for quantification of water in NADES with similar accuracy to ATR-IR. The present demonstration clearly highlights the potential of Raman spectroscopy to support the development of new analytical protocols in the field of green chemistry.
Collapse
Affiliation(s)
- Suha Elderderi
- Faculté de pharmacie, EA 6295 Nanomédicaments et Nanosondes, Université de Tours, 31 avenue Monge, 37200, Tours, France
- Faculty of Pharmacy, University of Gezira, 21111, Wad Madani, Gezira, Sudan
| | - Laura Wils
- Faculté de pharmacie, EA 7502 Synthèse et Isolement de Molécules BioActives (SIMBA), Université de Tours, 31 avenue Monge, 37200, Tours, France
| | - Charlotte Leman-Loubière
- Faculté de pharmacie, EA 7502 Synthèse et Isolement de Molécules BioActives (SIMBA), Université de Tours, 31 avenue Monge, 37200, Tours, France
| | - Sandra Henry
- Faculté de pharmacie, EA 6295 Nanomédicaments et Nanosondes, Université de Tours, 31 avenue Monge, 37200, Tours, France
| | - Hugh J Byrne
- FOCAS Research Institute, TU Dublin, City Campus, Dublin 8, Ireland
| | - Igor Chourpa
- Faculté de pharmacie, EA 6295 Nanomédicaments et Nanosondes, Université de Tours, 31 avenue Monge, 37200, Tours, France
| | - Emilie Munnier
- Faculté de pharmacie, EA 6295 Nanomédicaments et Nanosondes, Université de Tours, 31 avenue Monge, 37200, Tours, France
| | - Abdalla A Elbashir
- Faculty of Science, Department of Chemistry, University of Khartoum, 11115, Khartoum, Sudan
| | - Leslie Boudesocque-Delaye
- Faculté de pharmacie, EA 7502 Synthèse et Isolement de Molécules BioActives (SIMBA), Université de Tours, 31 avenue Monge, 37200, Tours, France
| | - Franck Bonnier
- Faculté de pharmacie, EA 6295 Nanomédicaments et Nanosondes, Université de Tours, 31 avenue Monge, 37200, Tours, France.
| |
Collapse
|
17
|
Kranenburg RF, Verduin J, de Ridder R, Weesepoel Y, Alewijn M, Heerschop M, Keizers PH, van Esch A, van Asten AC. Performance evaluation of handheld Raman spectroscopy for cocaine detection in forensic case samples. Drug Test Anal 2021; 13:1054-1067. [PMID: 33354929 PMCID: PMC8248000 DOI: 10.1002/dta.2993] [Citation(s) in RCA: 33] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2020] [Revised: 12/18/2020] [Accepted: 12/20/2020] [Indexed: 01/08/2023]
Abstract
Handheld Raman spectroscopy is an emerging technique for rapid on-site detection of drugs of abuse. Most devices are developed for on-scene operation with a user interface that only shows whether cocaine has been detected. Extensive validation studies are unavailable, and so are typically the insight in raw spectral data and the identification criteria. This work evaluates the performance of a commercial handheld Raman spectrometer for cocaine detection based on (i) its performance on 0-100 wt% binary cocaine mixtures, (ii) retrospective comparison of 3,168 case samples from 2015 to 2020 analyzed by both gas chromatography-mass spectrometry (GC-MS) and Raman, (iii) assessment of spectral selectivity, and (iv) comparison of the instrument's on-screen results with combined partial least square regression (PLS-R) and discriminant analysis (PLS-DA) models. The limit of detection was dependent on sample composition and varied between 10 wt% and 40 wt% cocaine. Because the average cocaine content in street samples is well above this limit, a 97.5% true positive rate was observed in case samples. No cocaine false positives were reported, although 12.5% of the negative samples were initially reported as inconclusive by the built-in software. The spectral assessment showed high selectivity for Raman peaks at 1,712 (cocaine base) and 1,716 cm-1 (cocaine HCl). Combined PLS-R and PLS-DA models using these features confirmed and further improved instrument performance. This study scientifically assessed the performance of a commercial Raman spectrometer, providing useful insight on its applicability for both presumptive detection and legally valid evidence of cocaine presence for law enforcement.
Collapse
Affiliation(s)
- Ruben F. Kranenburg
- Forensic LaboratoryDutch National Police, Unit AmsterdamAmsterdamThe Netherlands
- Van't Hoff Institute for Molecular SciencesUniversity of AmsterdamAmsterdamThe Netherlands
| | - Joshka Verduin
- Forensic LaboratoryDutch National Police, Unit AmsterdamAmsterdamThe Netherlands
- Van't Hoff Institute for Molecular SciencesUniversity of AmsterdamAmsterdamThe Netherlands
| | - Renee de Ridder
- Forensic LaboratoryDutch National Police, Unit AmsterdamAmsterdamThe Netherlands
| | - Yannick Weesepoel
- Wageningen Food Safety ResearchWageningen University and ResearchWageningenThe Netherlands
| | - Martin Alewijn
- Wageningen Food Safety ResearchWageningen University and ResearchWageningenThe Netherlands
| | | | - Peter H.J. Keizers
- National Institute of Public Health and the Environment (RIVM)BilthovenThe Netherlands
| | | | - Arian C. van Asten
- Van't Hoff Institute for Molecular SciencesUniversity of AmsterdamAmsterdamThe Netherlands
- Co van Ledden Hulsebosch Center (CLHC), Amsterdam Center for Forensic Science and MedicineAmsterdamThe Netherlands
| |
Collapse
|
18
|
Sanada T, Yoshida N, Kimura K, Tsuboi H. Discrimination of Falsified Erectile Dysfunction Medicines by Use of an Ultra-Compact Raman Scattering Spectrometer. PHARMACY 2020; 9:pharmacy9010003. [PMID: 33374339 PMCID: PMC7839056 DOI: 10.3390/pharmacy9010003] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2020] [Revised: 12/18/2020] [Accepted: 12/22/2020] [Indexed: 01/09/2023] Open
Abstract
Substandard and falsified medicines are often reported worldwide. An accurate and rapid detection method for falsified medicines is needed to prevent human health hazards. Raman scattering spectroscopy has emerged as a non-destructive analysis method for the detection of falsified medicines. In this laboratory study, Raman spectroscopy was performed to evaluate the applicability of the ultra-compact Raman scattering spectrometer (C13560). Principal component analysis (PCA) was also performed on the Raman spectra. This study analyzed tadalafil (Cialis), vardenafil (Levitra), and sildenafil (Viagra) tablets. We tested the standard product and products purchased from the internet (genuine or falsified). For Cialis and Levitra, all falsified tablets were identified by the Raman spectra and PCA score plot. For Viagra, the Raman spectra of some falsified tablets were almost comparable to the standard tablet. The PCA score plots of falsified tablets were dispersed, and some plots of falsified tablets were close to the standard tablet. In conclusion, C13560 was useful for the discrimination of falsified Cialis and Levitra tablets, whereas some falsified Viagra tablets had Raman spectra similar to that of the standard tablet. The development of detection methods that can be introduced in various settings may help prevent the spread of falsified products.
Collapse
Affiliation(s)
- Tomoko Sanada
- Clinical Pharmacy and Healthcare Sciences, Faculty of Pharmacy, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kakuma-Machi, Kanazawa 920-1192, Ishikawa, Japan; (T.S.); (H.T.)
| | - Naoko Yoshida
- AI Hospital/Macro Signal Dynamics Research and Development Center, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kakuma-Machi, Kanazawa 920-1192, Ishikawa, Japan
- Correspondence: ; Tel.: +81-(0)76-264-6286
| | - Kazuko Kimura
- Medi-Quality Security Institute, Graduate School of Medical Sciences, Kanazawa University, Kakuma-Machi, Kanazawa 920-1192, Ishikawa, Japan;
| | - Hirohito Tsuboi
- Clinical Pharmacy and Healthcare Sciences, Faculty of Pharmacy, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kakuma-Machi, Kanazawa 920-1192, Ishikawa, Japan; (T.S.); (H.T.)
| |
Collapse
|
19
|
Rapid detection of the aspergillosis biomarker triacetylfusarinine C using interference-enhanced Raman spectroscopy. Anal Bioanal Chem 2020; 412:6351-6360. [PMID: 32170382 PMCID: PMC7442771 DOI: 10.1007/s00216-020-02571-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2019] [Revised: 02/20/2020] [Accepted: 03/02/2020] [Indexed: 11/02/2022]
Abstract
Triacetylfusarinine C (TAFC) is a siderophore produced by certain fungal species and might serve as a highly useful biomarker for the fast diagnosis of invasive aspergillosis. Due to its renal elimination, the biomarker is found in urine samples of patients suffering from Aspergillus infections. Accordingly, non-invasive diagnosis from this easily obtainable body fluid is possible. Within our contribution, we demonstrate how Raman microspectroscopy enables a sensitive and specific detection of TAFC. We characterized the TAFC iron complex and its iron-free form using conventional and interference-enhanced Raman spectroscopy (IERS) and compared the spectra with the related compound ferrioxamine B, which is produced by bacterial species. Even though IERS only offers a moderate enhancement of the Raman signal, the employment of respective substrates allowed lowering the detection limit to reach the clinically relevant range. The achieved limit of detection using IERS was 0.5 ng of TAFC, which is already well within the clinically relevant range. By using an extraction protocol, we were able to detect 1.4 μg/mL TAFC via IERS from urine within less than 3 h including sample preparation and data analysis. We could further show that TAFC and ferrioxamine B can be clearly distinguished by means of their Raman spectra even in very low concentrations.
Collapse
|