1
|
Wu S, Khan MA, Zhang L, Zhao H, Huang T, Cao H, Ye D. Paper-based colorimetric sensor using a single-atom nanozyme for the ultrasensitive detection of Cr(VI) in short-necked clams. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024. [PMID: 39329181 DOI: 10.1039/d4ay00891j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/28/2024]
Abstract
Single-atom nanozymes (SAzymes) as a class of highly active nanozymes with the advantages of high atom utilization, high catalytic activity and stability have attracted great attention. In this work, Fe-N-C SAzymes with exceptional oxidase (OXD)-like activity were achieved utilizing polyvinylpyrrolidone (PVP) as a template. The Fe-N-C SAzymes with remarkable OXD-like activity could oxidize TMB to blue oxTMB, but 8-hydroxyquinoline (8-HQ) as a metal chelator is capable of discoloring oxTMB. Thus, the addition of 8-HQ decolorized the solution. However, upon the introduction of Cr(VI) ions, 8-HQ preferentially chelated with the Cr(VI) ions, reversing the inhibition of the color reaction and restoring the blue color. Based on this phenomenon, we constructed a novel paper-based analytical device (PAD) that exhibited a linear range of 5-1000 μM and an LOD of 1.2 μM. Importantly, the PAD used in this study shows the merits of simplicity, low preparation costs, and rapid reaction times. When combined with smartphone RGB analysis, it enables the simultaneous analysis of eight different Cr(VI) concentrations without the need for large-scale instrumentation. Moreover, the proposed PAD displays high selectivity, accuracy and utility in testing actual short-necked clam samples. This work not only provides a simple and cost-effective method to detect Cr(VI) but also makes a contribution to rapid food testing.
Collapse
Affiliation(s)
- Shuo Wu
- School of Food Science and Engineering, Hainan University, Haikou 570228, China.
| | - Muhammad Arif Khan
- Materials Science and Engineering, College of Sciences, Shanghai University, Shanghai 200444, PR China
| | - Lifan Zhang
- School of Food Science and Engineering, Hainan University, Haikou 570228, China.
| | - Hongbin Zhao
- Institute for Sustainable Energy/College of Sciences, Shanghai University, Shanghai 200444, PR China.
| | - Tianzeng Huang
- School of Chemistry and Chemical Engineering, Hainan University, Haikou 570228, China.
| | - Hongmei Cao
- School of Food Science and Engineering, Hainan University, Haikou 570228, China.
- Hainan Institute for Food Control, Key Laboratory of Tropical Fruits and Vegetables Quality and Safety for State Market Regulation, Haikou 570314, PR China
| | - Daixin Ye
- Institute for Sustainable Energy/College of Sciences, Shanghai University, Shanghai 200444, PR China.
| |
Collapse
|
2
|
Malik S, Singh J, Saini K, Chaudhary V, Umar A, Ibrahim AA, Akbar S, Baskoutas S. Paper-based sensors: affordable, versatile, and emerging analyte detection platforms. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:2777-2809. [PMID: 38639474 DOI: 10.1039/d3ay02258g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/20/2024]
Abstract
Paper-based sensors, often referred to as paper-based analytical devices (PADs), stand as a transformative technology in the field of analytical chemistry. They offer an affordable, versatile, and accessible solution for diverse analyte detection. These sensors harness the unique properties of paper substrates to provide a cost-effective and adaptable platform for rapid analyte detection, spanning chemical species, biomolecules, and pathogens. This review highlights the key attributes that make paper-based sensors an attractive choice for analyte detection. PADs demonstrate their versatility by accommodating a wide range of analytes, from ions and gases to proteins, nucleic acids, and more, with customizable designs for specific applications. Their user-friendly operation and minimal infrastructure requirements suit point-of-care diagnostics, environmental monitoring, food safety, and more. This review also explores various fabrication methods such as inkjet printing, wax printing, screen printing, dip coating, and photolithography. Incorporating nanomaterials and biorecognition elements promises even more sophisticated and sensitive applications.
Collapse
Affiliation(s)
- Sumit Malik
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Joginder Singh
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Kajal Saini
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Vivek Chaudhary
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Ahmad Umar
- Department of Chemistry, Faculty of Science and Arts, Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, Najran-11001, Kingdom of Saudi Arabia.
- Department of Materials Science and Engineering, The Ohio State University, Columbus 43210, OH, USA
- STEM Pioneers Training Lab, Najran University, Najran 11001, Kingdom of Saudi Arabia
| | - Ahmed A Ibrahim
- Department of Chemistry, Faculty of Science and Arts, Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, Najran-11001, Kingdom of Saudi Arabia.
- STEM Pioneers Training Lab, Najran University, Najran 11001, Kingdom of Saudi Arabia
| | - Sheikh Akbar
- Department of Materials Science and Engineering, The Ohio State University, Columbus 43210, OH, USA
| | | |
Collapse
|
3
|
Atabakhsh S, Haji Abbasali H, Jafarabadi Ashtiani S. Thermally programmable time delay switches for multi-step assays in paper-based microfluidics. Talanta 2024; 271:125695. [PMID: 38295445 DOI: 10.1016/j.talanta.2024.125695] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Revised: 12/18/2023] [Accepted: 01/17/2024] [Indexed: 02/02/2024]
Abstract
Paper-based microfluidic devices offer advantages such as low cost and disposability for point-of-care diagnostic applications. However, actuation of fluids on paper can be a challenge in multi-step and complex assays. In this work, a thermally programmable time-delay switch (TPTDS) is presented which operates by causing delays in the fluid path of a microfluidics paper-based analytical device (μPAD) by utilizing screen-printed wax micro-bridges. The time-delay is achieved through an electrical power feedback loop which indirectly adjusts the temperature of each individual micro-bridge, melting the wax into the paper. The melted wax manipulates the fluid flow depending on its penetration depth into the paper channel, which is a function of the applied temperature. To demonstrate functionality of the proposed method, the TPTDS is employed to automate and perform the nitrate assay which requires sequential delivery of reagents. Colorimetric detection is used to quantify the results by utilizing an electronic color sensor.
Collapse
Affiliation(s)
- Saeed Atabakhsh
- Department of Electrical Engineering, Roudehen Branch, Islamic Azad University, Roudehen, Iran
| | - Hossein Haji Abbasali
- School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, 14395/515, Iran
| | - Shahin Jafarabadi Ashtiani
- School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, 14395/515, Iran.
| |
Collapse
|
4
|
Muhammed A, Hussen A, Kaneta T. Adsorption enrichment integrated with paper-based devices for detection of trace levels of hexavalent chromium in water samples. ANAL SCI 2024; 40:709-717. [PMID: 38316712 DOI: 10.1007/s44211-023-00504-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 12/26/2023] [Indexed: 02/07/2024]
Abstract
In the present study, a sensitive microfluidic paper-based analytical device (μ-PADs) integrated with adsorption enrichment procedure was developed to analyze Cr(VI) in water samples. The affecting factors, including pH and amounts of reagents were optimized. The limit of detection of 0.0015 mg L-1 and linear range of 0.005-2 mg L-1 were achieved with good intra- and inter-day precision of 5.1 and 7.6% RSD, respectively. The results obtained by the proposed method were validated by inductively coupled plasma-optical emission spectrometry (ICP-OES). The recoveries of the present method and ICP-OES were ranged from 96.3 to 109.0% and 106.0 to 109.7%, respectively. The two sets of (μ-PADs and ICP-OES) results were in a good agreement as paired t-test indicated no significant differences. The proposed method could be utilized for analyzing trace levels of Cr(VI) in water samples in the absence of conventional analytical instruments.
Collapse
Affiliation(s)
- Abdellah Muhammed
- Department of Chemistry, College of Natural Sciences, Wollo University, P. O. Box: 1145, Dessie, Ethiopia
| | - Ahmed Hussen
- Center for Environmental Science, College of Natural and Computational Sciences, Addis Ababa University, P. O. Box: 1176, Addis Ababa, Ethiopia.
| | - Takashi Kaneta
- Department of Chemistry, Graduate School of Natural Science and Technology, Okayama University, 3-1-1 Tsushimanaka, Okayama, 700-8530, Japan
| |
Collapse
|
5
|
Fotouhi M, Seidi S, Razeghi Y, Torfinezhad S. A dual-mode assay kit using a portable potentiostat connected to a smartphone via Bluetooth communication and a potential-power angle-based paper device susceptible for low-cost point-of-care testing of iodide and dopamine. Anal Chim Acta 2024; 1287:342127. [PMID: 38182351 DOI: 10.1016/j.aca.2023.342127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Revised: 12/04/2023] [Accepted: 12/08/2023] [Indexed: 01/07/2024]
Abstract
BACKGROUND Considering that the brain controls most of the body's activities, it is very important to measure the factors affecting its function, such as dopamine and iodide. Due to the growing population in the world, it is necessary to provide fast, cheap and accurate methods with the capability of on-site analysis and without the need for invasive sampling and operator skill. As a result, there is a strong desire to replace laboratory instruments with small sensors for point-of-care testing. Paper-based analytical devices (PADs) are one of the popular zero-cost approaches to achieve this goal. RESULTS We developed a simple and disposable diagnostic paper system based on electroanalytical and potential-power angle-based methods. First, we prepared an angle-based analytical system capable of performing semi-quantitative iodide analysis simply by reading the colored angle traveled. This system design is based on a channel containing complex reagents and two pencil-drawn electrodes to apply a constant voltage accelerating the anions migration. Meanwhile, a three-electrode system based on conductive pencil graphite is developed to measure dopamine concentration based on linear sweep voltammetry. For the quantitative analysis, the voltammetric data was wirelessly transmitted to a mobile device via Bluetooth communication. In this context, a power supply providing the required voltage for the migration of iodide ions, a portable potentiostat system, and a mobile application for measuring dopamine were developed. The calibration curves for I- and dopamine range from 3.5 × 10-4-47.0 × 10-4 and 10.0 × 10-6-1000.0 × 10-6 mol L-1 with LODs of 2.3 × 10-4 and 5.0 × 10-6 mol L-1, respectively. SIGNIFICANCE AND NOVELTY A new portable dual-mode voltage-assisted integrated PAD platform was designed for iodide and dopamine analysis. The characteristics of this device allow non-experts to carry out in-field analysis using sub-100 μL saliva sample with a time-to-result of <10 min along with reducing the overall cost and operational complexity.
Collapse
Affiliation(s)
- Mina Fotouhi
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611, Tehran, Iran; Nanomaterial, Separation and Trace Analysis Research Lab, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611, Tehran, Iran
| | - Shahram Seidi
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611, Tehran, Iran; Nanomaterial, Separation and Trace Analysis Research Lab, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611, Tehran, Iran.
| | - Yasaman Razeghi
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611, Tehran, Iran; Nanomaterial, Separation and Trace Analysis Research Lab, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611, Tehran, Iran
| | - Shahab Torfinezhad
- Faculty of Electrical Engineering, K.N. Toosi University of Technology, Tehran, Iran
| |
Collapse
|
6
|
Rawat S, Misra N, Shelkar SA, Kumar V. Tailoring Acid Free-Paper based Analytical Devices (Af-PADs) via radiation assisted modification of cellulose paper. Carbohydr Polym 2023; 317:121116. [PMID: 37364946 DOI: 10.1016/j.carbpol.2023.121116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 05/31/2023] [Accepted: 06/09/2023] [Indexed: 06/28/2023]
Abstract
A novel green fabrication approach is being proposed based on radiation assisted modification of Whatman filter paper 1 (WFP) for development of Acid Free-Paper based Analytical Devices (Af-PADs). Af-PADs exude immense potential as handy tools for on-site detection of toxic pollutants such as, Cr(VI), boron, etc., which have established detection protocols involving acid mediated colorimetric reactions that necessitate external acid addition. The proposed Af-PAD fabrication protocol asserts its novelty through elimination of external acid addition step, making the detection process safer and simpler. To achieve this, poly(acrylic acid) (PAA) was grafted onto WFP via a single step, room temperature process of gamma radiation induced simultaneous irradiation grafting, introducing acidic -COOH groups in the paper thereon. Grafting parameters namely, absorbed dose and concentrations of monomer, homopolymer inhibitor and acid were optimized. The -COOH groups incorporated in PAA-grafted-WFP (PAA-g-WFP) provide localized acidic conditions for colorimetric reactions between pollutants and their sensing agents, anchored on the PAA-g-WFP. Af-PADs loaded with 1,5-diphenylcarbazide (DPC) have been ably demonstrated for visual detection and quantitative estimation of Cr(VI) in water samples using RGB image analysis, with LOD value of 1.2 mg.L-1 and a measurement range comparable to that of commercially available PADs based Cr(VI) visual detection kits.
Collapse
Affiliation(s)
- Swarnima Rawat
- Radiation Technology Development Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India; Homi Bhabha National Institute, Anushaktinagar, Mumbai 400094, India.
| | - Nilanjal Misra
- Radiation Technology Development Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India
| | - Shubhangi A Shelkar
- Radiation Technology Development Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India
| | - Virendra Kumar
- Radiation Technology Development Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India; Homi Bhabha National Institute, Anushaktinagar, Mumbai 400094, India
| |
Collapse
|
7
|
Ben Jaballah M, Karrat A, Amine A, Dridi C. Immobilization of diphenylcarbazide on paper-based analytical devices for the pre-concentration and detection of chromium VI in water samples. Talanta 2023; 265:124889. [PMID: 37399649 DOI: 10.1016/j.talanta.2023.124889] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 06/20/2023] [Accepted: 06/27/2023] [Indexed: 07/05/2023]
Abstract
A novel approach using a smartphone for the detection of Cr (VI) has been developed. In this context, two different platforms were designed for the detection of Cr (VI). The first one was synthesized via a crosslinking reaction of chitosan with 1,5-Diphenylcarbazide (DPC-CS). The obtained material was integrated into a paper to develop a new paper-based analytical device (DPC-CS-PAD). The DPC-CS-PAD exhibited high specificity toward Cr (VI). The second platform (DPC-Nylon PAD) was prepared by covalent immobilization of DPC onto a Nylon paper and then its analytical performances regarding Cr (VI) extraction and detection were evaluated. DPC-CS-PAD presented a linear range of 0.1-5 ppm with detection and quantification limits of about 0.04 and 0.12 ppm, respectively. The DPC-Nylon-PAD exhibited a linear response of 0.1-2.5 ppm with detection and quantification limits of 0.06 and 0.2 ppm, respectively. Furthermore, the developed platforms were effectively applied for testing the effect of the loading solution volume for trace Cr (IV) detection. For the DPC-CS material, a volume of 20 mL allowed the detection of 4 ppb of Cr (VI). In the case of DPC-Nylon-PAD, the loading volume of 1 mL permitted the detection of the critical concentration of Cr (VI) in water.
Collapse
Affiliation(s)
- Menyar Ben Jaballah
- NANOMISENE Laboratory, Centre for Research on Microelectronics and Nanotechnology CRMN of Sousse Technopole, B.P. 334, LR16CRMN01, Sahloul, Sousse, 4054, Tunisia
| | - Abdelhafid Karrat
- Laboratory of Process Engineering and Environment, Faculty of Sciences and Techniques, Hassan II University of Casablanca, P.A. 146., Mohammedia, Morocco
| | - Aziz Amine
- Laboratory of Process Engineering and Environment, Faculty of Sciences and Techniques, Hassan II University of Casablanca, P.A. 146., Mohammedia, Morocco.
| | - Chérif Dridi
- NANOMISENE Laboratory, Centre for Research on Microelectronics and Nanotechnology CRMN of Sousse Technopole, B.P. 334, LR16CRMN01, Sahloul, Sousse, 4054, Tunisia.
| |
Collapse
|
8
|
Fernandes GM, Barreto DN, Batista AD, da Silveira Petruci JF. A fully integrated 3D printed platform for sulfite determination in beverages via gas diffusion membrane extraction and digital video treatment. Food Chem 2023; 406:135094. [PMID: 36470085 DOI: 10.1016/j.foodchem.2022.135094] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 11/18/2022] [Accepted: 11/24/2022] [Indexed: 12/02/2022]
Abstract
In this study, we have described a miniaturized, simple, and low-cost device for sulfite determination in beverages by coupling Gas Diffusion Microextraction to paper-based analytical devices. The color change of an acid-base indicator - promoted by the generated gaseous SO2 - impregnated onto the paper surface was monitored in the function of time by video recording using a smartphone. The analytical information was related to the Hue, Saturation, Value (HSV) color space extracted from the video file. The complete analytical platform was built using a 3D printer, allowing the easy fabrication of a low-cost tailored device. Under optimized conditions, a linear relation from 5 to 90 mg L-1 was obtained using 30 µL of the reagent, 1 mL of sample, and 10 min of analysis. The relative standard deviation and the limit of detection were 2.2 % and 1.6 mg L-1, respectively. The method was successfully employed in several beverages, such as juices, soda, and coconut water.
Collapse
Affiliation(s)
| | - Diandra Nunes Barreto
- Federal University of Uberlândia (UFU), Institute of Chemistry, Uberlândia, MG, Brazil
| | | | | |
Collapse
|
9
|
Kohama N, Okazaki T, Sazawa K, Hata N, Kuramitz H, Taguchi S. Simple solid-phase colorimetry for trace Cr(VI) by combination of complexation with diphenylcarbazide and ion-pair solid-phase extraction with sedimentable dispersed particulates. ANAL SCI 2023; 39:857-865. [PMID: 36795319 DOI: 10.1007/s44211-023-00286-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Accepted: 02/01/2023] [Indexed: 02/17/2023]
Abstract
A highly sensitive and simple solid-phase colorimetry for Cr(VI) was proposed. It was based on the ion-pair solid-phase extraction of Cr-diphenylcarbazide (DPC) complex with sedimentable dispersed particulates. The concentration of Cr(VI) was measured from the color tones obtained by image analysis of the photo of sediment. Various conditions, e.g., material and amounts of adsorbent particulates, chemical properties and concentration of counter ions, and pH, were optimized for the formation and quantitative extraction of the complex. In the recommended procedure, 1 mL of sample was put into a 1.5 mL microtube where powder form adsorbent and reagents, i.e., XAD-7HP particles, DPC, sodium dodecyl sulfate, amido sulfuric acid, and sodium chloride had been packed. The analytical operation was completed within 5 min by gently shaking the microtube and allowing it to stand until enough amounts of particulates were deposited to take a picture. Chromium (VI) up to 2.0 ppm was determined, and the detection limit was 0.0034 ppm. The sensitivity was enough to determine Cr(VI) at lower concentrations than the water quality of standard (0.02 ppm). This method was successfully applied to the analysis of simulated industrial wastewater samples. The stoichiometry of the extracted chemical species was also investigated by applying the same equilibrium model as the ion-pair solvent extraction.
Collapse
Affiliation(s)
- Nozomi Kohama
- Department of Environmental Biology and Chemistry, Graduate School of Science and Engineering for Research, University of Toyama, Gofuku 3190, Toyama, 930-8555, Japan
| | - Takuya Okazaki
- Department of Applied Chemistry, School of Science and Technology, Meiji University, Kawasaki, Kanagawa, 214-8571, Japan
| | - Kazuto Sazawa
- Department of Environmental Biology and Chemistry, Graduate School of Science and Engineering for Research, University of Toyama, Gofuku 3190, Toyama, 930-8555, Japan
| | - Noriko Hata
- Department of Environmental Biology and Chemistry, Graduate School of Science and Engineering for Research, University of Toyama, Gofuku 3190, Toyama, 930-8555, Japan
| | - Hideki Kuramitz
- Department of Environmental Biology and Chemistry, Graduate School of Science and Engineering for Research, University of Toyama, Gofuku 3190, Toyama, 930-8555, Japan.
| | - Shigeru Taguchi
- Department of Environmental Biology and Chemistry, Graduate School of Science and Engineering for Research, University of Toyama, Gofuku 3190, Toyama, 930-8555, Japan
| |
Collapse
|
10
|
Fotouhi M, Nasihatkon B, Solouki S, Seidi S. A card instead of a lab: A ligand embedded in a bio-composite of starch/gelatin intelligent film for milk quality test followed by colorimetric analysis. Int J Biol Macromol 2023; 228:426-434. [PMID: 36563820 DOI: 10.1016/j.ijbiomac.2022.12.205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 12/16/2022] [Accepted: 12/17/2022] [Indexed: 12/24/2022]
Abstract
Milk adulteration analysis at different stages of the production chain, which profiteers widely use to mask milk quality parameters, is problematic. We prepared selective intelligent thin bio-films and a dedicated app to test milk adulteration in an out-of-lab setting. In this regard, each reagent is immobilized on a piece of starch/gelatin film as color-changeable polymeric support, which is then pasted onto a transparent test card. Incorporating starch and gelatin as the backbone of these composite films can significantly improve the mechanical properties, color, and potential applications in real-time monitoring. After 5 min floating of the card on the surface of the milk, our developed software as a Progressive Web Application can be used to locate and read the QR codes of the samples to estimate qualitative and quantitative information about the presence of some preservatives. These preservatives ranged from 0.1 to 200.0 mg/L, 1.0-100.0 mg/L, 0.001-0.05 mol/L in 10 mL of milk with the LODs of 0.1, 1.0 mg/L, and 0.001 mmol/L, for H2O2, Cr(VI), and salicylic acid, respectively. The pH monitoring film also indicates the freshness/spoilage of the milk. The portability, ease of use, and low cost of testing coupled with the app, make it an attractive alternative to lab-based analysis.
Collapse
Affiliation(s)
- Mina Fotouhi
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611 Tehran, Iran; Nanomaterial, Separation and Trace Analysis Research Lab, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611 Tehran, Iran
| | - Behrooz Nasihatkon
- Faculty of Computer Engineering, K. N. Toosi University of Technology, Tehran, Iran
| | - Sepehr Solouki
- Faculty of Computer Engineering, K. N. Toosi University of Technology, Tehran, Iran
| | - Shahram Seidi
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611 Tehran, Iran; Nanomaterial, Separation and Trace Analysis Research Lab, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611 Tehran, Iran.
| |
Collapse
|
11
|
Ren WQ, Ji B, Kuang Z, Fang F, Guo XL, Wu ZY. Paper-based Analytical Device for Fast Colorimetric Detection of Total Hemoglobin and Free Hemoglobin from Human Blood Sample. Microchem J 2023. [DOI: 10.1016/j.microc.2022.108380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
12
|
A dual-readout paper-based analytical device for the simultaneous determination of hexavalent Cr and total Cr. Mikrochim Acta 2022; 189:445. [DOI: 10.1007/s00604-022-05532-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Accepted: 10/10/2022] [Indexed: 11/13/2022]
|
13
|
Caroline Nava Pinheiro A, Souza Ferreira V, Gabriel Lucca B. Stamping method based on 3D printing and disposable napkin: Cheap production of paper analytical devices for alcohol determination in beverages aiming forensics and food control. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107604] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
14
|
Saadati M. A Simple Spot Test Method with Digital Imaging for Chromium Speciation in Water Samples. JOURNAL OF ANALYTICAL CHEMISTRY 2022. [DOI: 10.1134/s1061934822060089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
15
|
Development of a Screening Method for Sulfamethoxazole in Environmental Water by Digital Colorimetry Using a Mobile Device. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10010025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Antibiotic resistance is a major health concern of the 21st century. The misuse of antibiotics over the years has led to their increasing presence in the environment, particularly in water resources, which can exacerbate the transmission of resistance genes and facilitate the emergence of resistant microorganisms. The objective of the present work is to develop a chemosensor for screening of sulfonamides in environmental waters, targeting sulfamethoxazole as the model analyte. The methodology was based on the retention of sulfamethoxazole in disks containing polystyrene divinylbenzene sulfonated sorbent particles and reaction with p-dimethylaminocinnamaldehyde, followed by colorimetric detection using a computer-vision algorithm. Several color spaces (RGB, HSV and CIELAB) were evaluated, with the coordinate a_star, from the CIELAB color space, providing the highest sensitivity. Moreover, in order to avoid possible errors due to variations in illumination, a color palette is included in the picture of the analytical disk, and a correction using the a_star value from one of the color patches is proposed. The methodology presented recoveries of 82–101% at 0.1 µg and 0.5 µg of sulfamethoxazole (25 mL), providing a detection limit of 0.08 µg and a quantification limit of 0.26 µg. As a proof of concept, application to in-field analysis was successfully implemented.
Collapse
|
16
|
Alahmad W, Sahragard A, Varanusupakul P. Online and offline preconcentration techniques on paper-based analytical devices for ultrasensitive chemical and biochemical analysis: A review. Biosens Bioelectron 2021; 194:113574. [PMID: 34474275 DOI: 10.1016/j.bios.2021.113574] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 08/18/2021] [Accepted: 08/18/2021] [Indexed: 12/24/2022]
Abstract
Microfluidic paper-based analytical devices (μPADs) have attracted much attention over the past decade. They embody many advantages, such as abundance, portability, cost-effectiveness, and ease of fabrication, making them superior for clinical diagnostics, environmental monitoring, and food safety assurance. Despite these advantages, μPADs lack the high sensitivity to detect many analytes at trace levels than other commercial analytical instruments such as mass spectrometry. Therefore, a preconcentration step is required to enhance their sensitivity. This review focuses on the techniques used to separate and preconcentrate the analytes onto the μPADs, such as ion concentration polarization, isotachophoresis, and field amplification sample stacking. Other separations and preconcentration techniques, including liquid-solid and liquid-liquid extractions coupled with μPADs, are also reviewed and discussed. In addition, the fabrication methods, advantages, disadvantages, and the performance evaluation of the μPADs concerning their precision and accuracy were highlighted and critically assessed. Finally, the challenges and future perspectives have been discussed.
Collapse
Affiliation(s)
- Waleed Alahmad
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, Thailand.
| | - Ali Sahragard
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, Thailand
| | - Pakorn Varanusupakul
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, Thailand.
| |
Collapse
|
17
|
Alahmad W, Sahragard A, Varanusupakul P. An overview of the recent developments of microfluidic paper-based analytical devices for the detection of chromium species. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106699] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
18
|
Tai WC, Chang YC, Chou D, Fu LM. Lab-on-Paper Devices for Diagnosis of Human Diseases Using Urine Samples-A Review. BIOSENSORS 2021; 11:260. [PMID: 34436062 PMCID: PMC8393526 DOI: 10.3390/bios11080260] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 07/26/2021] [Accepted: 07/29/2021] [Indexed: 12/23/2022]
Abstract
In recent years, microfluidic lab-on-paper devices have emerged as a rapid and low-cost alternative to traditional laboratory tests. Additionally, they were widely considered as a promising solution for point-of-care testing (POCT) at home or regions that lack medical infrastructure and resources. This review describes important advances in microfluidic lab-on-paper diagnostics for human health monitoring and disease diagnosis over the past five years. The review commenced by explaining the choice of paper, fabrication methods, and detection techniques to realize microfluidic lab-on-paper devices. Then, the sample pretreatment procedure used to improve the detection performance of lab-on-paper devices was introduced. Furthermore, an in-depth review of lab-on-paper devices for disease measurement based on an analysis of urine samples was presented. The review concludes with the potential challenges that the future development of commercial microfluidic lab-on-paper platforms for human disease detection would face.
Collapse
Affiliation(s)
- Wei-Chun Tai
- Department of Oral and Maxillofacial Surgery, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung 833, Taiwan;
| | - Yu-Chi Chang
- Department of Engineering Science, National Cheng Kung University, Tainan 701, Taiwan;
| | - Dean Chou
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan;
| | - Lung-Ming Fu
- Department of Engineering Science, National Cheng Kung University, Tainan 701, Taiwan;
- Graduate Institute of Materials Engineering, National Pingtung University of Science and Technology, Pingtung 912, Taiwan
| |
Collapse
|
19
|
KATO T, MANAKA A, ANDO R, OSHITE S, YAMAGUCHI H, IGARASHI S. Performance Evaluation of a Portable Quantitative Analysis Method Combined with Liquid–liquid Extraction and Smartphone. BUNSEKI KAGAKU 2021. [DOI: 10.2116/bunsekikagaku.70.469] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Takeshi KATO
- Materials Analysis Station, National Institute for Materials Science
| | - Atsushi MANAKA
- Department of Applied Chemistry and Chemical Engineering, National Institute of Technology, Toyama College
| | - Ryo ANDO
- Industrial Technology Innovation Center of Ibaraki Prefecture
| | - Shigekatu OSHITE
- Department of Applied Chemistry and Biochemistry, National Institute of Technology, Fukushima College
| | - Hitoshi YAMAGUCHI
- Materials Analysis Station, National Institute for Materials Science
| | - Shukuro IGARASHI
- Department of Materials Science and Engineering, College of Engineering, Ibaraki University
| |
Collapse
|
20
|
Zhai HM, Ji B, Tian SS, Fang F, Zhao S, Wu ZY. Cr speciation analysis based on electrokinetic sample pretreatment with a paper based analytical device. Talanta 2021; 234:122656. [PMID: 34364465 DOI: 10.1016/j.talanta.2021.122656] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 06/22/2021] [Accepted: 06/23/2021] [Indexed: 11/25/2022]
Abstract
This work presents a new method of Cr speciation analysis based on micro sample pretreatment with a paper-based analytical device (PAD). By using electrokinetic separation and stacking on the PAD, Cr (VI) and Cr (III) can be separated and the recovered to achieve speciation analysis without have to be subjected to subtraction treatment. The separation and recovery properties of Cr (VI) and Cr (III) were characterized and optimized by UV-Vis spectrophotometry, with which the LOQ of 19.0 μg L-1 and 28.7 μg L-1, and the recoveries of 88-108% and 90-110%, were obtained for Cr (VI) and Cr (III), respectively. In addition, direct analysis of Cr (VI)/Cr (III) from an electroplating wastewater sample was also demonstrated with this method combined with atomic spectroscopy (GF-AAS and ICP-OES). This sample pretreatment method is fast, cheap and easy to be used. Combined with the high sensitivity and elemental selectivity of atomic spectroscopy and mass spectrometry, this PAD sample pretreatment method could be a compensation to their lack in speciation discrimination, and may play an important role in the speciation analysis of Cr.
Collapse
Affiliation(s)
- Hui-Min Zhai
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China
| | - Bin Ji
- The First Affiliated Hospital of China Medical University, Shenyang, 110819, China
| | - Shan-Shan Tian
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China
| | - Fang Fang
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China
| | - Shuang Zhao
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China
| | - Zhi-Yong Wu
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China.
| |
Collapse
|
21
|
Ng HY, Lee WC, Kung CT, Li LC, Lee CT, Fu LM. Recent Advances in Microfluidic Devices for Contamination Detection and Quality Inspection of Milk. MICROMACHINES 2021; 12:558. [PMID: 34068982 PMCID: PMC8156775 DOI: 10.3390/mi12050558] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 05/05/2021] [Accepted: 05/11/2021] [Indexed: 02/08/2023]
Abstract
Milk is a necessity for human life. However, it is susceptible to contamination and adulteration. Microfluidic analysis devices have attracted significant attention for the high-throughput quality inspection and contaminant analysis of milk samples in recent years. This review describes the major proposals presented in the literature for the pretreatment, contaminant detection, and quality inspection of milk samples using microfluidic lab-on-a-chip and lab-on-paper platforms in the past five years. The review focuses on the sample separation, sample extraction, and sample preconcentration/amplification steps of the pretreatment process and the determination of aflatoxins, antibiotics, drugs, melamine, and foodborne pathogens in the detection process. Recent proposals for the general quality inspection of milk samples, including the viscosity and presence of adulteration, are also discussed. The review concludes with a brief perspective on the challenges facing the future development of microfluidic devices for the analysis of milk samples in the coming years.
Collapse
Affiliation(s)
- Hwee-Yeong Ng
- Division of Nephrology, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung 833, Taiwan; (H.-Y.N.); (W.-C.L.); (L.-C.L.); (C.-T.L.)
| | - Wen-Chin Lee
- Division of Nephrology, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung 833, Taiwan; (H.-Y.N.); (W.-C.L.); (L.-C.L.); (C.-T.L.)
| | - Chia-Te Kung
- Department of Emergency Medicine, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung 833, Taiwan;
| | - Lung-Chih Li
- Division of Nephrology, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung 833, Taiwan; (H.-Y.N.); (W.-C.L.); (L.-C.L.); (C.-T.L.)
| | - Chien-Te Lee
- Division of Nephrology, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung 833, Taiwan; (H.-Y.N.); (W.-C.L.); (L.-C.L.); (C.-T.L.)
| | - Lung-Ming Fu
- Department of Engineering Science, National Cheng Kung University, Tainan 701, Taiwan
| |
Collapse
|
22
|
Lee WC, Ng HY, Hou CY, Lee CT, Fu LM. Recent advances in lab-on-paper diagnostic devices using blood samples. LAB ON A CHIP 2021; 21:1433-1453. [PMID: 33881033 DOI: 10.1039/d0lc01304h] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Lab-on-paper, or microfluidic paper-based analytical devices (μPADs), use paper as a substrate material, and are patterned with a system of microchannels, reaction zones and sensing elements to perform analysis and detection. The sample transfer in such devices is performed by capillary action. As a result, external driving forces are not required, and hence the size and cost of the device are significantly reduced. Lab-on-paper devices have thus attracted significant attention for point-of-care medical diagnostic purposes in recent years, particularly in less-developed regions of the world lacking medical resources and infrastructures. This review discusses the major advances in lab-on-paper technology for blood analysis and diagnosis in the past five years. The review focuses particularly on the many clinical applications of lab-on-paper devices, including diabetes diagnosis, acute myocardial infarction (AMI) detection, kidney function diagnosis, liver function diagnosis, cholesterol and triglyceride (TG) analysis, sickle-cell disease (SCD) and phenylketonuria (PKU) analysis, virus analysis, C-reactive protein (CRP) analysis, blood ion analysis, cancer factor analysis, and drug analysis. The review commences by introducing the basic transmission principles, fabrication methods, structural characteristics, detection techniques, and sample pretreatment process of modern lab-on-paper devices. A comprehensive review of the most recent applications of lab-on-paper devices to the diagnosis of common human diseases using blood samples is then presented. The review concludes with a brief summary of the main challenges and opportunities facing the lab-on-paper technology field in the coming years.
Collapse
Affiliation(s)
- Wen-Chin Lee
- Division of Nephrology, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung, 833, Taiwan.
| | - Hwee-Yeong Ng
- Division of Nephrology, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung, 833, Taiwan.
| | - Chih-Yao Hou
- Department of Seafood Science, National Kaohsiung University of Science and Technology, Kaohsiung 811, Taiwan
| | - Chien-Te Lee
- Division of Nephrology, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung, 833, Taiwan.
| | - Lung-Ming Fu
- Department of Engineering Science, National Cheng Kung University, Tainan, 701, Taiwan.
| |
Collapse
|
23
|
Muhammed A, Hussen A, Redi M, Kaneta T. Remote Investigation of Total Chromium Determination in Environmental Samples of the Kombolcha Industrial Zone, Ethiopia, Using Microfluidic Paper-based Analytical Devices. ANAL SCI 2021; 37:585-592. [PMID: 33041309 DOI: 10.2116/analsci.20p325] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Microfluidic paper-based analytical devices (μ-PADs) fabricated in Japan were employed for the determination of total chromium (Cr) in water, soil, and lettuce irrigated with wastewater in Ethiopia. The μ-PADs, which were printed by wax printing in Japan, were transported to Ethiopia and prepared for the determination of total Cr by adding appropriate reagents to the pretreatment and detection zones. Soil and lettuce samples were determined by the μ-PADs and a UV-Vis spectrophotometer in Ethiopia. A paired t-test showed that the mean total Cr concentrations determined in the soil and lettuce samples were not significantly different between μ-PADs and UV-Vis spectrophotometric analysis at the 5% level of significance. This implies that the μ-PADs have good accuracy and reliability, and could be employed to monitor Cr in environmental samples. We found that the total Cr concentrations in all soil and lettuce samples were above the permissible limit. Moreover, evaluating Cr contamination level using the geo-accumulation index indicated that the soils were contaminated with Cr moderately to heavily. Thus, the present work successfully demonstrated the potential of remote investigations of pollution in a less-equipped laboratory by transporting the μ-PADs fabricated in another laboratory.
Collapse
Affiliation(s)
- Abdellah Muhammed
- Center for Environmental Science, College of Natural and Computational Sciences, Addis Ababa University
| | - Ahmed Hussen
- Center for Environmental Science, College of Natural and Computational Sciences, Addis Ababa University
| | - Mesfin Redi
- Department of Chemistry, College of Natural and Computational Sciences, Addis Ababa University
| | - Takashi Kaneta
- Department of Chemistry, Graduate School of Natural Science and Technology, Okayama University
| |
Collapse
|
24
|
Zhiyue M, Xichen Y, Li R, Yang Y, Huicheng F, Peng S. Recent advances in paper-based preconcentrators by utilizing ion concentration polarization. Electrophoresis 2021; 42:1340-1351. [PMID: 33768593 DOI: 10.1002/elps.202000291] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 02/26/2021] [Accepted: 03/15/2021] [Indexed: 11/09/2022]
Abstract
One of the most cited limitations of biochemical detection is its poor sensitivity, owing to the relatively high complexity of micro-samples. Moreover, some samples cannot be easily self-replicated and their abundance cannot be increased through traditional technologies. Therefore, the preconcentration of low-abundance samples is a key requirement for microfluidic biological analysis. In recent years, the ion-concentration polarization phenomenon has aroused widespread interest in the application of microfluidic technology. In addition, paper-based materials are readily available, easy to modify, and exhibit good hydrophilicity. The study of the ion-concentration polarization preconcentration of micro-samples in paper-based microfluidic chips is of considerable significance. In this review, we discuss the development and applications of ion-concentration polarization paper-based preconcentrator in the past 5 years, with emphasis on key progresses in chip fabrication and performance optimization under different conditions. The current needs and development prospects in this field have also been discussed.
Collapse
Affiliation(s)
- Meng Zhiyue
- School of Life Sciences, Northwestern Polytechnical University, Xi'an, P. R. China.,Key Laboratory for Space Bioscience and Biotechnology, Institute of Special Environment Biophysics, Northwestern Polytechnical University, Xi'an, P. R. China
| | - Yuan Xichen
- School of Life Sciences, Northwestern Polytechnical University, Xi'an, P. R. China.,Research and Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, P. R. China.,Key Laboratory for Space Bioscience and Biotechnology, Institute of Special Environment Biophysics, Northwestern Polytechnical University, Xi'an, P. R. China.,Yangtze River Delta Research Institute of Northwestern Polytechnical University, Taicang, P. R. China
| | - Ren Li
- School of Life Sciences, Northwestern Polytechnical University, Xi'an, P. R. China.,Research and Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, P. R. China.,Key Laboratory for Space Bioscience and Biotechnology, Institute of Special Environment Biophysics, Northwestern Polytechnical University, Xi'an, P. R. China
| | - Yang Yang
- Ministry of Education Key Laboratory of Low-grade Energy Utilization Technologies and Systems, Chongqing University, Chongqing, P. R. China
| | - Feng Huicheng
- Unmanned System Research Institute, Northwestern Polytechnical University, Xi'an, P. R. China.,MOE Key Laboratory of Micro and Nano Systems for Aerospace, Northwestern Polytechnical University, Xi'an, P. R. China
| | - Shang Peng
- School of Life Sciences, Northwestern Polytechnical University, Xi'an, P. R. China.,Research and Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, P. R. China.,Key Laboratory for Space Bioscience and Biotechnology, Institute of Special Environment Biophysics, Northwestern Polytechnical University, Xi'an, P. R. China
| |
Collapse
|
25
|
Speciation of chromium in water samples using microfluidic paper-based analytical devices with online oxidation of trivalent chromium. Anal Bioanal Chem 2021; 413:3339-3347. [PMID: 33715041 DOI: 10.1007/s00216-021-03274-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 02/28/2021] [Accepted: 03/03/2021] [Indexed: 10/21/2022]
Abstract
Speciation of chromium (Cr) was demonstrated using microfluidic paper-based analytical devices (μ-PADs) that permit the colorimetric determination of hexavalent chromium (Cr(VI)) and trivalent chromium (Cr(III)) via online oxidation. The μ-PADs consist of left and right channels that allow the simultaneous measurements of Cr(VI) and total Cr based on the colorimetric reaction of Cr(VI) with 1,5-diphenylcarbazide (DPC). For the determination of Cr(VI), a sample solution was directly reacted with DPC in the left channels whereas total Cr was determined in the right channels, which permitted online oxidation in the pretreatment zone containing cerium (IV) (Ce(IV)) followed by a colorimetric reaction with DPC. We found that the online oxidation of Cr(III) proceeded 100% whereas Ce(IV) inhibited the reaction of Cr(VI) with DPC. Therefore, speciation can be achieved by measuring the Cr(VI) and total Cr in the left and right channels followed by the subtraction of Cr(VI) from total Cr. The limits of detection and quantification were 0.008 and 0.02 mg L-1 for Cr(VI) and 0.07 and 0.1 mg L-1 for Cr(III) or total Cr, respectively. The linear dynamic ranges were 0.02-100 mg L-1 and 0.1-60 mg L-1 for Cr(VI) and Cr(III), respectively. The RSDs were less than 7.5%. The results obtained using μ-PADs were in good agreement with those obtained via ICP-OES with recoveries of 92-108% for Cr(III) and 108-110% for Cr (VI) using μ-PADs, and 106-110% for total Cr using ICP-OES. Thus, the μ-PADs could potentially be utilized for the speciation of chromium in developing countries where environmental pollution and the availability of sophisticated instruments are significant problems.
Collapse
|