1
|
Silva-Neto HA, Jaime JC, Rocha DS, Sgobbi LF, Coltro WKT. Fabrication of paper-based analytical devices using stencil-printed glass varnish barriers for colorimetric detection of salivary α-amylase. Anal Chim Acta 2024; 1297:342336. [PMID: 38438226 DOI: 10.1016/j.aca.2024.342336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 01/30/2024] [Accepted: 02/04/2024] [Indexed: 03/06/2024]
Abstract
BACKGROUND Developing disposable paper-based devices has positively impacted analytical science, particularly in developing countries. Some benefits of those devices include their versatility, affordability, environmentally friendly, and the possibility of being integrated with portable electrochemical or colorimetric detectors. Paper-based analytical devices (PADs) comprising circular zones and microfluidic networks have been successfully employed in the analytical chemistry reign. However, the combination of the stencil-printing method and alternative binder has not been satisfactorily explored for fabricating colorimetric paper devices. RESULTS We developed PADs exploring the stencil printing approach and glass varnish as the hydrophobic chemical agent. As a proof-of-concept, the colorimetric assay of salivary α-amylase (sAA) was performed in saliva samples. Through the scanning electron microscopy measurements, it was possible to indicate satisfactory definitions between native fibers and barrier, and that the measured values for the channel width revealed suitable fidelity (R2 = 0.99) with the nominal widths (ranging from 400 to 5000 μm). The proposed hydrophobic barrier exhibited excellent chemical resistance. The analytical applicability for detecting sAA revealed linear behavior in the range from 2 to 12 U mL-1 (R2 = 0.99), limit of detection of 0.75 U mL-1, reproducibility (RSD ≤2.4%), recovery experiments ranged from 89 to 108% and AGREE response (0.86). In addition, the colorimetric analysis of sAA in four different saliva samples demonstrated levels ranging from 202 to 2080 U mL-1, which enabled monitoring the absence and presence of periodontitis. SIGNIFICANCE This report has presented the first use of a self-adhesive mask and glass varnish for creating circular zones and microfluidic architectures on paper without using thermic or UV curing treatments. Also, the proposed analytical methodology for detecting sAA exhibited suitable ecological impact considering the AGREE tool. We believe the proposed fabrication of paper devices emerges as a novel, simple, high-fidelity microfluidic channel and portable analytical approach for colorimetric sensing.
Collapse
Affiliation(s)
- Habdias A Silva-Neto
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil
| | - Jordana C Jaime
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil
| | - Danielly S Rocha
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil
| | - Livia F Sgobbi
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil
| | - Wendell K T Coltro
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil; Instituto Nacional de Ciência e Tecnologia de Bioanalítica, 13084-971, Campinas, SP, Brazil.
| |
Collapse
|
2
|
Carvalho RM, Pedão ER, Roese Guerbas FM, Tronchini MP, Ferreira VS, Petroni JM, Lucca BG. Electrochemical study and forensic electroanalysis of fungicide benzovindiflupyr using disposable graphite pencil electrode. Talanta 2023; 252:123873. [DOI: 10.1016/j.talanta.2022.123873] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 08/19/2022] [Accepted: 08/22/2022] [Indexed: 11/29/2022]
|
3
|
Paper-based electrochemical platform modified with graphene nanoribbons: A new and affordable approach for analysis of 5-hydroxy-l-tryptophan. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
4
|
Grazioli C, Dossi N, Cesaro F, Svigelj R, Toniolo R, Bontempelli G. A 3D printed Do-It-Yourself miniaturized device with a sensor responsive at six different wavelengths for reflectance measurements on paper-based supports. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
5
|
Caroline Nava Pinheiro A, Souza Ferreira V, Gabriel Lucca B. Stamping method based on 3D printing and disposable napkin: Cheap production of paper analytical devices for alcohol determination in beverages aiming forensics and food control. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107604] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
6
|
3D-printed microfluidic thread device with integrated detector: a green and portable tool for amperometric detection of fungicide benzovindiflupyr in forensic samples. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
7
|
A novel 3D-printed batch injection analysis (BIA) cell coupled to paper-based electrochemical devices: A cheap and reliable analytical system for fast on-site analysis. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107663] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
8
|
Simple, fast, and instrumentless fabrication of paper analytical devices by novel contact stamping method based on acrylic varnish and 3D printing. Mikrochim Acta 2021; 188:437. [PMID: 34837526 DOI: 10.1007/s00604-021-05102-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Accepted: 11/11/2021] [Indexed: 12/27/2022]
Abstract
A new contact stamping method for fabrication of paper-based analytical devices (PADs) is reported. It uses an all-purpose acrylic varnish and 3D-printed stamps to pattern hydrophobic structures on paper substrates. The use of 3D printing allows quickly prototyping the desired stamp shape without resorting to third-party services, which are often expensive and time consuming. To the best of our knowledge, this is the first report regarding the use of this material for creation of hydrophobic barriers in paper substrates, as well as this 3D printing-based stamping method. The acrylic varnish was characterized and the features of the stamping method were studied. The PADs developed here presented better compatibility with organic solvents and surfactants compared with similar protocols. Furthermore, the use of this contact stamping method for fabrication of paper electrochemical devices was also possible, as well as multiplexed microfluidic devices for lateral flow testing. The analytical applicability of the varnish-based PADs was demonstrated through the image-based colorimetric quantification of iron in pharmaceutical samples. A limit of detection of 0.61 mg L-1 was achieved. The results were compared with spectrophotometry for validation and presented great concordance (relative error was < 5% and recoveries were between 104 and 108%). Thus, taking into account the performance of the devices explored here, we believe this novel contact stamping method is a very interesting alternative for production of PADs, exhibiting great potentiality. In addition, this work brings a new application of 3D printing in analytical sciences.
Collapse
|
9
|
Microfluidic colorimetric detection platform with sliding hybrid PMMA/paper microchip for human urine and blood sample analysis. Talanta 2021; 231:122362. [PMID: 33965028 DOI: 10.1016/j.talanta.2021.122362] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Revised: 03/18/2021] [Accepted: 03/21/2021] [Indexed: 02/07/2023]
Abstract
A microfluidic colorimetric detection (MCD) platform consisting of a sliding hybrid PMMA/paper microchip and a smart analysis system is proposed for the convenient, low-cost and rapid analysis of human urine and whole blood samples. The sliding PMMA/paper microchip comprises a PMMA microfluidic chip for sample injection and transportation, a paper strip for sample filtration (urine) or separation (blood), and a sealed paper-chip detection zone for sample reaction and detection. In the proposed device, the paper-chip is coated with bicinchoninic acid (BCA) and biuret reagent and is then assembled into the PMMA microchip and packaged in aluminum housing. In the detection process, the PMMA/paper microchip is slid partially out of the housing, and 2 μL of sample (urine or whole blood) is dripped onto the sample injection zone. The chip is then slid back into the housing and the sample is filtered/separated by the paper strip and transferred under the effects of capillary action to the sealed paper-chip detection zone. The housing is inserted into the color analysis system and heated at 45 °C for 5 min to produce a purple-colored reaction complex. The complex is imaged using a CCD camera and the RGB color intensity of the image is then analyzed using a smartphone to determine the total protein (TP) concentration of the sample. The effectiveness of the proposed method is demonstrated using TP control samples with known concentrations in the range of 0.03-5.0 g/dL. The detection results obtained for 50 human urine samples obtained from random volunteers are shown to be consistent with those obtained from a conventional hospital analysis system (R2 = 0.992). Moreover, the detection results obtained for the albumin (ALB) and creatine (CRE) concentrations of 50 whole blood samples are also shown to be in good agreement with the results obtained from the hospital analysis system (R2 = 0.982 and 0.988, respectively).
Collapse
|
10
|
Development of a High-Throughput Low-Cost Approach for Fabricating Fully Drawn Paper-Based Analytical Devices Using Commercial Writing Tools. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9070178] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
This work reports the development and optimization of a rapid and low-cost pen-on-paper plotting approach for the fabrication of paper-based analytical devices (PADs) using commercial writing stationery. The desired fluidic patterns were drawn on the paper substrate with commercial marker pens using an inexpensive computer-controlled x–y plotter. For the fabrication of electrochemical PADs, electrodes were further deposited on the devices using a second x–y plotting step with commercial writing pencils. The effect of the fabrication parameters (type of paper, type of marker pen, type of pencil, plotting speed, number of passes, single- vs. double-sided plotting), the chemical resistance of the plotted devices to different solvents and the structural rigidity to multiple loading cycles were assessed. The analytical utility of these devices is demonstrated through application in optical sensing of total phenols using reflectance calorimetry and in electrochemical sensing of paracetamol and ascorbic acid. The proposed manufacturing approach is simple, low cost, flexible, rapid and fit-for-purpose and enables the fabrication of sub-“one-dollar” PADs with satisfactory mechanical and chemical resistance and good analytical performance.
Collapse
|
11
|
Carvalho RM, Ferreira VS, Lucca BG. A novel all-3D-printed thread-based microfluidic device with an embedded electrochemical detector: first application in environmental analysis of nitrite. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:1349-1357. [PMID: 33656036 DOI: 10.1039/d1ay00070e] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
A microfluidic thread electroanalytical device (μTED) containing an embedded electrochemical detector is presented for the first time in this work. This novel device was entirely produced in an automated way using the fused deposition modeling (FDM) 3D printing technique. The main platform was fabricated with acrylonitrile butadiene styrene (ABS) filament, while the integrated electrochemical detector was produced using a commercial conductive filament composed of carbon black and polylactic acid (CB/PLA). The microfluidic channels consisted of cotton threads, which act as passive pumps, and the μTED was used for microflow injection analysis (μFIA). As a proof of concept, this μFIA system was utilized for the amperometric sensing of nitrite in natural waters. This is the first report on the use of both μTEDs and 3D-printed CB/PLA electrodes to determine this species. This fully 3D-printed μTED was characterized and all experimental and instrumental parameters related to the method were studied and optimized. Using the best conditions, the proposed approach showed a linear response in the concentration range from 8 to 200 μmol L-1 and a limit of detection (LOD) of 2.39 μmol L-1. The LOD obtained here was ca. ten-fold lower than the maximum contaminant level for nitrite in drinking water established by the Brazilian and US legislation. Moreover, the platform presented good repeatability and reproducibility (relative standard deviations (RSDs) were 2.1% and 2.5%, respectively). Lastly, the 3D-printed μTED was applied for the quantification of nitrite in well water samples and the results obtained showed good precision (RSD < 3%) and excellent concordance (relative error was ca.±3%) with those achieved by ion chromatography, used for validation.
Collapse
Affiliation(s)
- Rayan Marcel Carvalho
- Chemistry Institute, Federal University of Mato Grosso do Sul, Campo Grande, MS 79074-460, Brazil.
| | | | | |
Collapse
|
12
|
Aquino A, Mayrink Alves Pereira G, Dossi N, Piccin E, Augusti R. Reagent-Pencil and Paper Spray Mass Spectrometry: A Convenient Combination for Selective Analyses in Complex Matrixes. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:281-288. [PMID: 33176096 DOI: 10.1021/jasms.0c00321] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The recent developments on fieldable miniature mass spectrometers require efforts to produce easy-to-use and portable alternative tools to assist in point-of-care analysis. In this paper, the reagent-pencil (RP) technology, which has been used for solvent-free deposition of reagents in paper-based microfluidics, was combined with paper spray ionization mass spectrometry (PS-MS). In this approach, named RP-PS-MS, the PS triangular piece of paper was written with the reagent pencil, consisting of mixtures of graphite and bentonite (used as a support) and a reactive compound, and allowed to react with a given analyte from a sample matrix selectively. We conducted typical applications as proof-of-principles to verify the methodology's general usefulness in detecting small organic molecules in distinct samples. Hence, various aldehydes (2-furaldehyde, valeraldehyde, and benzaldehyde) in spiked cachaça samples (an alcoholic drink produced from fermentation/distillation of sugarcane juice) were promptly detected using a reagent pencil doped with 4-aminophenol (the reactive compound). Similarly, we recognized typical ginsenosides and triacylglycerols (TAGs) in ginseng aqueous infusions and soybean oil samples, respectively, using lithium chloride as the reactive compound. The results indicate that the reagent-pencil methodology is compatible with PS-MS and provides an easy and fast way to detect target analytes in complex samples. The advantage over the usual solution-based deposition of reagents lies in the lack of preparation or carrying different specific solutions for special applications, which can simplify operation, especially in point-of-care analysis with fieldable mass spectrometers.
Collapse
Affiliation(s)
- Adriano Aquino
- Universidade Federal de Minas Gerais, Instituto de Ciências Exatas, Departamento de Química, Belo Horizonte, 31270-400, Minas Gerais, Brazil
| | - Giovana Mayrink Alves Pereira
- Universidade Federal de Minas Gerais, Instituto de Ciências Exatas, Departamento de Química, Belo Horizonte, 31270-400, Minas Gerais, Brazil
| | - Nicolò Dossi
- Department of Agrifood, Environmental and Animal Science, University of Udine, Udine, I-33100, Italy
| | - Evandro Piccin
- Universidade Federal de Minas Gerais, Instituto de Ciências Exatas, Departamento de Química, Belo Horizonte, 31270-400, Minas Gerais, Brazil
| | - Rodinei Augusti
- Universidade Federal de Minas Gerais, Instituto de Ciências Exatas, Departamento de Química, Belo Horizonte, 31270-400, Minas Gerais, Brazil
| |
Collapse
|
13
|
Development of novel paper-based electrochemical device modified with CdSe/CdS magic-sized quantum dots and application for the sensing of dopamine. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2020.137486] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
14
|
Catalan-Carrio R, Akyazi T, Basabe-Desmonts L, Benito-Lopez F. Predicting Dimensions in Microfluidic Paper Based Analytical Devices. SENSORS (BASEL, SWITZERLAND) 2020; 21:E101. [PMID: 33375225 PMCID: PMC7794781 DOI: 10.3390/s21010101] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Revised: 12/19/2020] [Accepted: 12/23/2020] [Indexed: 11/29/2022]
Abstract
The main problem for the expansion of the use of microfluidic paper-based analytical devices and, thus, their mass production is their inherent lack of fluid flow control due to its uncontrolled fabrication protocols. To address this issue, the first step is the generation of uniform and reliable microfluidic channels. The most common paper microfluidic fabrication method is wax printing, which consists of two parts, printing and heating, where heating is a critical step for the fabrication of reproducible device dimensions. In order to bring paper-based devices to success, it is essential to optimize the fabrication process in order to always get a reproducible device. Therefore, the optimization of the heating process and the analysis of the parameters that could affect the final dimensions of the device, such as its shape, the width of the wax barrier and the internal area of the device, were performed. Moreover, we present a method to predict reproducible devices with controlled working areas in a simple manner.
Collapse
Affiliation(s)
- Raquel Catalan-Carrio
- Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC) Group, Analytical Chemistry Department, University of the Basque Country UPV/EHU, 01006 Vitoria-Gasteiz, Spain; (R.C.-C.); (T.A.)
- Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, 01006 Vitoria-Gasteiz, Spain
| | - Tugce Akyazi
- Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC) Group, Analytical Chemistry Department, University of the Basque Country UPV/EHU, 01006 Vitoria-Gasteiz, Spain; (R.C.-C.); (T.A.)
| | - Lourdes Basabe-Desmonts
- Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, 01006 Vitoria-Gasteiz, Spain
- Basque Foundation for Science, IKERBASQUE, 48013 Bilbao, Spain
- Bioaraba Health Research Institute, Microfluidics Cluster UPV/EHU, 01006 Vitoria-Gasteiz, Spain
- BCMaterials, Basque Centre for Materials, Micro and Nanodevices, UPV/EHU Science Park, 48940 Leioa, Spain
| | - Fernando Benito-Lopez
- Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC) Group, Analytical Chemistry Department, University of the Basque Country UPV/EHU, 01006 Vitoria-Gasteiz, Spain; (R.C.-C.); (T.A.)
- Bioaraba Health Research Institute, Microfluidics Cluster UPV/EHU, 01006 Vitoria-Gasteiz, Spain
- BCMaterials, Basque Centre for Materials, Micro and Nanodevices, UPV/EHU Science Park, 48940 Leioa, Spain
| |
Collapse
|
15
|
Instrument-free and visual detection of organophosphorus pesticide using a smartphone by coupling aggregation-induced emission nanoparticle and two-dimension MnO 2 nanoflake. Biosens Bioelectron 2020; 170:112668. [PMID: 33032200 DOI: 10.1016/j.bios.2020.112668] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Revised: 09/27/2020] [Accepted: 09/29/2020] [Indexed: 12/12/2022]
Abstract
Given the importance of food safety, it is highly desirable to develop a convenient, low-cost, and practical sensor for organophosphorus pesticides (OPs) detection. Here, a fluorescent paper analytical device (FPAD) based on aggregation-induced emission (AIE) nanoparticles (PTDNPs-0.10) and two-dimension MnO2 nanoflakes (2D-MnNFs) was developed for instrument-free and naked-eye analysis of OPs. PTDNP-MnNFs composites were obtained through 2D-MnNFs and PTDNPs-0.10 by electrostatic interaction and the fluorescence emission of PTDNPs-0.10 was quenched through fluorescence resonance energy transfer (FRET). When acetylcholinesterase (AChE) was present, acetylthiocholine (ATCh) was catalytically hydrolyzed into thiocholine, which reduced MnO2 of PTDNP-MnNFs into Mn2+, subsequently blocking the FRET and enhancing the fluorescence. Upon the addition of OP, AChE activity was depressed and thus the FRET between 2D-MnNFs and PTDNPs-0.10 was not affected, resulting in a slight change in fluorescence. On the basis of the variation in fluorescence intensity, highly sensitive detection of OP was readily achieved with a detection limit of 0.027 ng/mL; on the basis of the variation in brightness of FPAD, instrument-free and visual detection of OP was realized using a smartphone with a detection limit of 0.73 ng/mL. The application of FPAD has significantly simplified the detection procedure and decreased the test cost, supplying a new approach for on-site detection of OPs.
Collapse
|