1
|
A N B, O D H, N S K, A V Z, B B D. Immunodetection of Poorly Soluble Substances: Limitations and Their Overcoming. Crit Rev Anal Chem 2024:1-26. [PMID: 39360478 DOI: 10.1080/10408347.2024.2402835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/04/2024]
Abstract
Immunoassays based on the specific antigen-antibody interactions are efficient tools to detect various compounds and estimate their content. Usually, these assays are implemented in water-saline media with composition close to physiological conditions. However, many substances are insoluble or cannot be molecularly dispersed in such media, which objectively creates problems when interacting in aquatic environments. Thus, obtaining immunoreactants and implementing immunoassays of these substances need special methodological solutions. Hydrophobicity of antigens as well as their limited ability to functionalization and conjugation are often overlooked when developing immunoassays for these compounds. The main key finding is the possibility to influence the behavior of hydrophobic compounds for immunoassays, which requires specific approaches summarized in the review. Using the examples of two groups of compounds-surfactants (alkyl- and bisphenols) and fullerenes, we systematized the existing knowledge and experience in the development of immunoassays. This review addresses the challenges of immunodetection of poorly soluble substances and proposes solutions such as the use of hydrotropes, other solubilization techniques, and alternative receptors (aptamers and molecularly imprinted polymers).
Collapse
Affiliation(s)
- Berlina A N
- Research Center of Biotechnology of the Russian Academy of Sciences, A. N. Bach Institute of Biochemistry, Moscow, Russia
| | - Hendrickson O D
- Research Center of Biotechnology of the Russian Academy of Sciences, A. N. Bach Institute of Biochemistry, Moscow, Russia
| | - Komova N S
- Research Center of Biotechnology of the Russian Academy of Sciences, A. N. Bach Institute of Biochemistry, Moscow, Russia
| | - Zherdev A V
- Research Center of Biotechnology of the Russian Academy of Sciences, A. N. Bach Institute of Biochemistry, Moscow, Russia
| | - Dzantiev B B
- Research Center of Biotechnology of the Russian Academy of Sciences, A. N. Bach Institute of Biochemistry, Moscow, Russia
| |
Collapse
|
2
|
Luis-Sunga M, Carinelli S, García G, González-Mora JL, Salazar-Carballo PA. Electrochemical Detection of Bisphenol A Based on Gold Nanoparticles/Multi-Walled Carbon Nanotubes: Applications on Glassy Carbon and Screen Printed Electrodes. SENSORS (BASEL, SWITZERLAND) 2024; 24:2570. [PMID: 38676187 PMCID: PMC11054518 DOI: 10.3390/s24082570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Revised: 04/12/2024] [Accepted: 04/13/2024] [Indexed: 04/28/2024]
Abstract
Bisphenol A (BPA) has been classified as an endocrine-disrupting substance that may cause adverse effects on human health and the environment. The development of simple and sensitive electrochemical biosensors is crucial for the rapid and effective quantitative determination of BPA. This work presents a study on electrochemical sensors utilizing gold nanoparticle-modified multi-walled carbon nanotubes (CNT/AuNPs). Glassy carbon electrodes (GCEs) and screen-printed electrodes (SPEs) were conveniently modified and used for BPA detection. AuNPs were electrodeposited onto the CNT-modified electrodes using the galvanostatic method. The electrodes were properly modified and characterized by using Raman spectroscopy, cyclic voltammetry (CV), and electrochemical impedance analysis (EIS). The electrochemical response of the sensors was studied using differential pulse voltammetry (DPV) and constant potential amperometry (CPA) for modified GCE and SPE electrodes, respectively, and the main analytical parameters were studied and optimized. Problems encountered with the use of GCEs, such as sensor degradation and high limit of detection (LOD), were overcome by using modified SPEs and a flow injection device for the measurements. Under this approach, an LOD as low as 5 nM (S/N = 3) was achieved and presented a linear range up to 20 μM. Finally, our investigation addressed interference, reproducibility, and reusability aspects, successfully identifying BPA in both spiked and authentic samples, including commercial and tap waters. These findings underscore the practical applicability of our method for accurate BPA detection in real-world scenarios. Notably, the integration of SPEs and a flow injection device facilitated simplified automation, offering an exceptionally efficient and reliable solution for precise BPA detection in water analysis laboratories.
Collapse
Affiliation(s)
- Maximina Luis-Sunga
- Laboratory of Sensors, Biosensors and Advanced Materials, Faculty of Health Sciences, Universidad de la Laguna, Campus de Ofra s/n, 38071 La Laguna, Spain; (M.L.-S.); (J.L.G.-M.); (P.A.S.-C.)
- Departamento de Química, Instituto Universitario de Materiales y Nanotecnología, Universidad de la Laguna, P.O. Box 456, 38200 La Laguna, Spain;
| | - Soledad Carinelli
- Laboratory of Sensors, Biosensors and Advanced Materials, Faculty of Health Sciences, Universidad de la Laguna, Campus de Ofra s/n, 38071 La Laguna, Spain; (M.L.-S.); (J.L.G.-M.); (P.A.S.-C.)
- Departamento de Ciencias Médicas Básicas and Instituto de Tecnologías Biomédicas, Universidad de La Laguna, 38200 La Laguna, Spain
| | - Gonzalo García
- Departamento de Química, Instituto Universitario de Materiales y Nanotecnología, Universidad de la Laguna, P.O. Box 456, 38200 La Laguna, Spain;
| | - José Luis González-Mora
- Laboratory of Sensors, Biosensors and Advanced Materials, Faculty of Health Sciences, Universidad de la Laguna, Campus de Ofra s/n, 38071 La Laguna, Spain; (M.L.-S.); (J.L.G.-M.); (P.A.S.-C.)
- Departamento de Ciencias Médicas Básicas and Instituto de Tecnologías Biomédicas, Universidad de La Laguna, 38200 La Laguna, Spain
- Instituto Universitario de Neurociencia, Universidad de la Laguna, 38071 Santa Cruz de Tenerife, Spain
| | - Pedro A. Salazar-Carballo
- Laboratory of Sensors, Biosensors and Advanced Materials, Faculty of Health Sciences, Universidad de la Laguna, Campus de Ofra s/n, 38071 La Laguna, Spain; (M.L.-S.); (J.L.G.-M.); (P.A.S.-C.)
| |
Collapse
|
3
|
Souza ID, Queiroz MEC. Organic-silica hybrid monolithic sorbents for sample preparation techniques: A review on advances in synthesis, characterization, and applications. J Chromatogr A 2024; 1713:464518. [PMID: 38000199 DOI: 10.1016/j.chroma.2023.464518] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Revised: 11/14/2023] [Accepted: 11/16/2023] [Indexed: 11/26/2023]
Abstract
Organic-silica hybrid monolithic materials have attracted considerable attention as potential stationary phases in separation science. These materials combine the advantages of organic polymer and silica-based monoliths, including easy preparation, lower back pressure, high permeability, excellent mechanical strength, thermal stability, and tunable surface chemistry with high surface area and selectivity. The outstanding chromatographic efficiency as stationary phase of hybrid monolithic capillary columns for capillary liquid chromatography and capillary electrochromatography has been reported in many papers. Organic-silica hybrid monolithic materials have also been extensively used in the field of sample preparation. Owing to their surface functionalities, these porous sorbents offer unique selectivity for pre-concentration of different analytes in the most complex matrixes by fast dynamic transport. These sorbents not only improve the analytical method sensitivity, but also introduce novelties in terms of extraction devices and instrument coupling strategies. The current review covers the period spanning from 2017 to 2023 and describes the properties of organic-inorganic hybrid monolithic materials, the present status of this technology and summarizes recent developments in their use as innovative sorbents for microextraction sample preparation techniques (solid phase microextraction with pipette tip, offline in-tube SPME, in-tube SPME online with LC, and in-tube SPME directly coupled with mass spectrometry). Aspects such as the synthesis methods (sol-gel process, one-pot approach, and polyhedral oligomeric silsesquioxanes-based procedure), characterization techniques, and strategies to improve extraction efficiency in various applications in different areas (environmental, food, bioanalysis, and proteomics) are also discussed.
Collapse
Affiliation(s)
- Israel D Souza
- Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, University of Sao Paulo, Av. Bandeirantes, 3900, Ribeirao Preto, SP 14040-901, Brazil.
| | - Maria Eugênia C Queiroz
- Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, University of Sao Paulo, Av. Bandeirantes, 3900, Ribeirao Preto, SP 14040-901, Brazil
| |
Collapse
|
4
|
Song F, Zhang Z, Xu X, Lin X. Online highly selective recognition of domoic acid by an aptamer@MOFs affinity monolithic column coupled with HPLC for shellfish safety monitoring. RSC Adv 2023; 13:30876-30884. [PMID: 37869383 PMCID: PMC10588371 DOI: 10.1039/d3ra05901d] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Accepted: 10/09/2023] [Indexed: 10/24/2023] Open
Abstract
Enabling cost-effective safety monitoring of shellfish is an important measure for the healthy development of the coastal marine economy. Herein, a new aptamer@metal-organic framework (MOF)-functionalized affinity monolithic column was proposed and applied in selective in-tube solid-phase microextraction (IT-SPME) coupled with HPLC for the accurate recognition of domoic acid (DA) in shellfish. Using a surface engineering strategy, ZIF-8 MOF was grown in situ inside the poly(epoxy-MA-co-POSS-MA) hybrid monolith. A high BET surface area and abundant metal reactive sites of the MOF framework were obtained for anchoring massive aptamers with terminal-modified phosphate groups. Various characterizations, such as SEM, elemental mapping, XRD, and BET, were performed, and the affinity performance was also studied. The presence of a massive amount of aptamers with a super coverage density of 3140 μmol L-1 bound on ZIF-8 MOF activated a high-performance bionic-affinity interface, and perfect specificity was exhibited with little interference of tissue matrixes, thus assuring the highly selective capture of DA from the complex matrixes. Under the optimal conditions, DA toxins in shellfish were detected with the limit of detection (LOD) of 7.0 ng mL-1 (equivalent to 14.0 μg kg-1), representing a 5-28 fold enhancement in detection sensitivity over traditional SPE or MIP adsorbents reported previously. The recoveries of fortified mussel and clam samples were achieved as 91.8 ± 1.2%-94.1 ± 1.9% (n = 3) and 91.2 ± 1.1%-94.5 ± 3.6% (n = 3), respectively. This work sheds light on a cost-effective method for online selective IT-SPME and the accurate monitoring of DA toxins using an aptamer@MOF-mediated affinity monolith system coupled with the inexpensive HPLC-UV technique.
Collapse
Affiliation(s)
- Fang Song
- College of Economics and Management, Fujian Agriculture and Forestry University Fuzhou 350001 China
| | - Zhexiang Zhang
- Engineering Technology Research Center on Reagent and Instrument for Rapid Detection of Product Quality and Food Safety in Fujian Province, Fuzhou University Fuzhou 350108 China
| | - Xuerong Xu
- College of Economics and Management, Fujian Agriculture and Forestry University Fuzhou 350001 China
| | - Xucong Lin
- Engineering Technology Research Center on Reagent and Instrument for Rapid Detection of Product Quality and Food Safety in Fujian Province, Fuzhou University Fuzhou 350108 China
| |
Collapse
|
5
|
Zajickova Z. Review of recent advances in development and applications of organic-silica hybrid monoliths. J Sep Sci 2023; 46:e2300396. [PMID: 37582653 DOI: 10.1002/jssc.202300396] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 07/31/2023] [Accepted: 08/01/2023] [Indexed: 08/17/2023]
Abstract
Organic-silica hybrid monoliths attracted attention as an alternative to extensively researched organic polymer-based and silica-based counterparts. The development and applications of these materials as extraction and separation media in capillary liquid chromatography and capillary electrochromatography were previously reviewed in several manuscripts. In this review, we will concentrate on work published since mid-2016 focusing on advances in their development using sol-gel chemistry of tetra- and trialkoxysilanes and subsequent surface modification with organic monomers, and "one-pot" strategy incorporating sol-gel chemistry of alkoxysilanes and free-radical polymerization, ring-opening polymerization, or thiol-based click polymerization with organic monomers. Approaches adapted to the preparation of hybrid monoliths made with polyhedral oligomeric silsesquioxanes will be covered as well.
Collapse
Affiliation(s)
- Zuzana Zajickova
- Department of Chemistry and Physics, Barry University, Miami, Florida, USA
| |
Collapse
|
6
|
Wang A, Liu J, Yang J, Yang L. Aptamer affinity-based microextraction in-line coupled to capillary electrophoresis mass spectrometry using a porous layer/nanoparticle -modified open tubular column. Anal Chim Acta 2023; 1239:340750. [PMID: 36628776 DOI: 10.1016/j.aca.2022.340750] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Revised: 12/20/2022] [Accepted: 12/23/2022] [Indexed: 12/26/2022]
Abstract
An aptamer affinity based microextraction column is developed to be directly in-line coupled to capillary electrophoresis-mass spectrometry (CE-MS) for analyzing mycotoxins in food samples. Single-stranded DNA aptamers for selective recognition of aflatoxin B1 (AFB1) and ochratoxin A (OTA) targets are co-immobilized via covalent bonds on the surface of the inlet end of a capillary, which is pre-modified with three-dimensional porous layer and gold nanoparticles to enhance the specific surface area and loading capacity. The outlet of the capillary is designed as a porous tip to serve as the spray source for injection to the mass spectrometry. All the necessary processes for pretreatment and analysis of a sample are accomplished in one injection, including aptamer affinity-based microextraction, CE separation and MS detection of analytes. AFB1 and OTA are simultaneously determined in a wide linear range with sample consumption of only 1 μL and the limit-of-detection as low as 1 pg/mL. The microextraction column exhibits excellent repeatability and stability, which can be used over 45 runs within a month with CE separation efficiency and only MS intensity slightly decreased. Mycotoxins in three kinds of cereal based infant foods are accurately analyzed using the proposed method. The study provides a robust and universal approach that would have potential applications in a variety of analytical fields based on selective molecular recognition coupling to CE-MS analysis.
Collapse
Affiliation(s)
- Anping Wang
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Department of Chemistry, Northeast Normal University, Changchun, 130024, China
| | - Jianing Liu
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Department of Chemistry, Northeast Normal University, Changchun, 130024, China
| | - Jinlan Yang
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Department of Chemistry, Northeast Normal University, Changchun, 130024, China
| | - Li Yang
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Department of Chemistry, Northeast Normal University, Changchun, 130024, China.
| |
Collapse
|
7
|
Szubartowski S, Tuzimski T. Application of High-Performance Liquid Chromatography Combined with Fluorescence Detector and Dispersive Liquid-Liquid Microextraction to Quantification of Selected Bisphenols in Human Amniotic Fluid Samples. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 20:297. [PMID: 36612618 PMCID: PMC9819170 DOI: 10.3390/ijerph20010297] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 12/19/2022] [Accepted: 12/20/2022] [Indexed: 06/17/2023]
Abstract
Bisphenol A (BPA) is a widely produced chemical worldwide found in numerous everyday products. Its endocrine-disrupting properties and omnipresence have aroused concern and led to several restrictions on its use. These restrictions and growing public awareness about the toxicity of BPA have resulted in market products labeled "BPA-free", with BPAs often being replaced by other bisphenols. This is why constant biomonitoring of bisphenol levels in various body fluids and tissues is essential. In this study, we propose the use of simple, cost-effective high-performance liquid chromatography coupled with the fluorescence detector (HPLC-FLD) method for the determination of simultaneously selected bisphenols in amniotic fluid. For the sample preparation, a fast, simple, and "green" dispersive liquid-liquid microextraction (DLLME) method was used, achieving mean recovery values in the range of 80.9-115.9% with relative standard deviations below 12% for all analytes. Limits of quantification (LOQs) determined in the amniotic fluid matrix ranged from 6.17 to 22.72 ng/mL and were obtained from a calibration curve constructed using least-squares linear regression analysis for all cases. The presented sample preparation procedure can be easily adopted for LC-MS analysis.
Collapse
Affiliation(s)
- Szymon Szubartowski
- Department of Physical Chemistry, Medical University of Lublin, Chodźki 4a, 20-093 Lublin, Poland
- Doctoral School of Medical University of Lublin, Medical University of Lublin, Chodźki 7, 20-093 Lublin, Poland
| | - Tomasz Tuzimski
- Department of Physical Chemistry, Medical University of Lublin, Chodźki 4a, 20-093 Lublin, Poland
| |
Collapse
|
8
|
Xu CY, Ning KP, Wang Z, Yao Y, Xu Q, Hu XY. Flexible Electrochemical Platform Coupled with In Situ Prepared Synthetic Receptors for Sensitive Detection of Bisphenol A. BIOSENSORS 2022; 12:1076. [PMID: 36551043 PMCID: PMC9775942 DOI: 10.3390/bios12121076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Revised: 11/15/2022] [Accepted: 11/21/2022] [Indexed: 06/17/2023]
Abstract
A flexible electrochemical sensor based on the carbon felt (CF) functionalized with Bisphenol A (BPA) synthetic receptors was developed. The artificial Bisphenol A receptors were grafted on the CF by a simple thermal polymerization molecular imprinting process. Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and electrochemical characterizations were used to analyze the receptors. Characterization results demonstrated that the Bisphenol A synthetic receptors successfully formed on the CFs surface. Because the synthetic receptor and the porous CFs were successfully combined, the sensor displayed a better current response once Bisphenol A was identified. The sensor's linear range was determined to be from 0.5 to 8.0 nM and 10.0 to 300.0 nM, with a detection limit of 0.36 nM. Even after being bent and stretched repeatedly, the electrode's performance was unaffected, demonstrating the robustness, adaptability and viability of installing the sensor on flat or curved surfaces for on-site detection. The designed electrochemical sensor has been used successfully to identify Bisphenol A in milk samples with satisfactory results. This work provided a promising platform for the design of implantable, portable and miniaturized sensors.
Collapse
|
9
|
Xu Z, Yu S, Mo W, Tang Y, Cheng Y, Ding L, Chen M, Peng S. Facile and Sensitive Method for Detecting Bisphenol A UsingUbiquitous pH Meters. ChemistrySelect 2022. [DOI: 10.1002/slct.202202002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Zhou Xu
- Hunan Provincial Key Laboratory of Cytochemistry School of Food Science and Bioengineering Changsha University of Science & Technology Changsha 410114 China
| | - ShaoYi Yu
- Hunan Provincial Key Laboratory of Cytochemistry School of Food Science and Bioengineering Changsha University of Science & Technology Changsha 410114 China
| | - WeiXi Mo
- Hunan Provincial Key Laboratory of Cytochemistry School of Food Science and Bioengineering Changsha University of Science & Technology Changsha 410114 China
| | - Yao Tang
- Hunan Provincial Key Laboratory of Cytochemistry School of Food Science and Bioengineering Changsha University of Science & Technology Changsha 410114 China
| | - Yunhui Cheng
- Hunan Provincial Key Laboratory of Cytochemistry School of Food Science and Bioengineering Changsha University of Science & Technology Changsha 410114 China
- School of Food Science and Engineering Qilu University of Technology, Jinan, Shandong, 250353, China
| | - Li Ding
- Hunan Provincial Key Laboratory of Cytochemistry School of Food Science and Bioengineering Changsha University of Science & Technology Changsha 410114 China
| | - Maolong Chen
- Hunan Provincial Key Laboratory of Cytochemistry School of Food Science and Bioengineering Changsha University of Science & Technology Changsha 410114 China
| | - Shuang Peng
- Hunan Provincial Key Laboratory of Cytochemistry School of Food Science and Bioengineering Changsha University of Science & Technology Changsha 410114 China
- College of Chemistry and Chemical Engineering Hunan University Changsha 410082 Hunan China
| |
Collapse
|
10
|
Chen J, Huang X, Ye R, Huang D, Wang Y, Chen S. Fabrication of a novel electrochemical sensor using conductive MOF Cu-CAT anchored on reduced graphene oxide for BPA detection. J APPL ELECTROCHEM 2022. [DOI: 10.1007/s10800-022-01735-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
|
11
|
Ye RH, Chen JY, Huang DH, Wang YJ, Chen S. Electrochemical Sensor Based on Glassy-Carbon Electrode Modified with Dual-Ligand EC-MOFs Supported on rGO for BPA. BIOSENSORS 2022; 12:bios12060367. [PMID: 35735515 PMCID: PMC9221176 DOI: 10.3390/bios12060367] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Revised: 05/08/2022] [Accepted: 05/20/2022] [Indexed: 11/16/2022]
Abstract
The electronic conductive metal-organic frameworks (EC-MOFs) based on a single ligand are not suitable for the accurate detection of bisphenol A (BPA) due to the limitations of their electron-transfer-based sensing mechanism. To overcome this drawback, we developed EC-MOFs with novel dual-ligands, 2,3,6,7,10,11-hexahydroxy-sanya-phenyl (HHTP) and tetrahydroxy 1,4-quinone (THQ), and metal ions. A new class of 2D π-conjugation-based EC-MOFs (M-(HHTP)(THQ)) was synthesized by a self-assemble technique. Its best member (Cu-(HHTP)(THQ)) was selected and combined with reduced graphene (rGO) to form a Cu-(HHTP)(THQ)@rGO composite, which was thoroughly characterized by X-ray diffraction, field scanning electron microscopy, and energy-dispersive X-ray spectroscopy. Cu-(HHTP)(THQ)@rGO was drop-cast onto a glassy carbon electrode (GCE) to obtain a sensor for BPA detection. Cyclic voltammetry and electrochemical impedance tests were used to evaluate the electrode performance. The oxidation current of BPA on the Cu-(HHTP)(THQ)@rGO/GCE was substantially higher than on unmodified GCE, which could be explained by a synergy between Cu-(HHTP)(THQ) (which provided sensing and adsorption) and rGO (which provided fast electron conductivity and high surface area). Cu-(HHTP)(THQ)@rGO/GCE exhibited a linear detection range for 0.05–100 μmol·L−1 of BPA with 3.6 nmol·L−1 (S/N = 3) detection limit. We believe that our novel electrode and BPA sensing method extends the application perspectives of EC-MOFs in the electrocatalysis and sensing fields.
Collapse
Affiliation(s)
- Rui-Hong Ye
- Fujian Province-Indonesia Marine Food Joint Research and Development Center, Fujian Polytechnic Normal University, Fuqing 350300, China; (R.-H.Y.); (Y.-J.W.); (S.C.)
| | - Jin-Yang Chen
- College of Life Sciences, Fujian Normal University, Fuzhou 350117, China;
| | - Di-Hui Huang
- Fujian Province-Indonesia Marine Food Joint Research and Development Center, Fujian Polytechnic Normal University, Fuqing 350300, China; (R.-H.Y.); (Y.-J.W.); (S.C.)
- Correspondence:
| | - Yan-Jun Wang
- Fujian Province-Indonesia Marine Food Joint Research and Development Center, Fujian Polytechnic Normal University, Fuqing 350300, China; (R.-H.Y.); (Y.-J.W.); (S.C.)
| | - Sheng Chen
- Fujian Province-Indonesia Marine Food Joint Research and Development Center, Fujian Polytechnic Normal University, Fuqing 350300, China; (R.-H.Y.); (Y.-J.W.); (S.C.)
| |
Collapse
|
12
|
Wang J, Zhu L, Li T, Li X, Huang K, Xu W. Multiple functionalities of functional nucleic acids for developing high-performance lateral flow assays. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116529] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
13
|
Zhang X, Jin Y, Wang Y, Liang P, Zou M, Li S, Liu J, Qi X, Zhang X, Shang Z, Chen Y, Chen Q. Measurement of trace bisphenol A in drinking water with combination of immunochromatographic detection technology and SERS method. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2022; 267:120519. [PMID: 34801391 DOI: 10.1016/j.saa.2021.120519] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2021] [Revised: 10/13/2021] [Accepted: 10/15/2021] [Indexed: 06/13/2023]
Abstract
Sensitive and selective detection of target analyte is very important in many fields such as commodity inspection and quality monitoring. In this work, based on the principle of competitive immunoassay, surface-enhanced Raman spectroscopy (SERS) was used to establish a rapid and highly sensitive method for the detection of trace amounts of bisphenol A in water. Here, Raman molecule 5,5-dithiobis-2-nitrobenzoic acid and anti-BPA antibody were conjugated with Au (core)@Ag (shell) nanoparticle to serve as SERS nanoprobe. After the SERS nanoprobe is combined with the substance to be tested, it uses the siphon effect to pass through the test line and the charging line on the test strip. And the Raman test was performed on the T line with a Raman spectrometer. The detection limitation was 0.1 pg/mL. Compared with the reported gas chromatography, liquid chromatography, fluorescence analysis, and other detection methods, SERS ICA does not demand complicated sample preparation procedures, and has the advantages of simple detection methods, quick results, High sensitivity, good specificity, and low technical demands for laboratory environment and testers. In addition, Raman spectrometers have gradually developed to be portable, making it easier to meet the needs of on-site rapid and highly sensitive detection, and will show broad prospects for applications in the fields of biomedical diagnosis and food safety monitoring.
Collapse
Affiliation(s)
- Xiubin Zhang
- College of Optical and Electronic Technology, China Jiliang University, 310018 Hangzhou, China
| | - Yong Jin
- Chinese Academy of Inspection and Quarantine (CAIQ), No. A 3, Gaobeidian Road, Chaoyang District, Beijing 100123, China
| | - Yufeng Wang
- MOE Joint International Research Laboratory of Animal Health and Food Safety, College of Veterinary Medicine, Nanjing Agricultural University, Nanjing 210095, China
| | - Pei Liang
- College of Optical and Electronic Technology, China Jiliang University, 310018 Hangzhou, China.
| | - Minqiang Zou
- Chinese Academy of Inspection and Quarantine (CAIQ), No. A 3, Gaobeidian Road, Chaoyang District, Beijing 100123, China.
| | - Suyang Li
- College of Optical and Electronic Technology, China Jiliang University, 310018 Hangzhou, China
| | - Jian Liu
- Chinese Academy of Inspection and Quarantine (CAIQ), No. A 3, Gaobeidian Road, Chaoyang District, Beijing 100123, China
| | - Xiaohua Qi
- Chinese Academy of Inspection and Quarantine (CAIQ), No. A 3, Gaobeidian Road, Chaoyang District, Beijing 100123, China
| | - Xiaohua Zhang
- China Inspection Laboratory Technologies Co. Ltd (CILT), Beijing 100123, China
| | - Ziyang Shang
- College of Optical and Electronic Technology, China Jiliang University, 310018 Hangzhou, China
| | - Yan Chen
- Chinese Academy of Inspection and Quarantine (CAIQ), No. A 3, Gaobeidian Road, Chaoyang District, Beijing 100123, China
| | - Qiang Chen
- College of Metrology and Measurement Engineering, China Jiliang University, 310018 Hangzhou, China
| |
Collapse
|
14
|
Xu Z, Zhang Z, She Z, Lin C, Lin X, Xie Z. Aptamer-functionalized metal-organic framework-coated nanofibers with multi-affinity sites for highly sensitive, selective recognition of ultra-trace microcystin-LR. Talanta 2022; 236:122880. [PMID: 34635260 DOI: 10.1016/j.talanta.2021.122880] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 09/08/2021] [Accepted: 09/10/2021] [Indexed: 11/26/2022]
Abstract
A novel aptamer-functionalized metal-organic framework nanofibrous composite (viz. PAN/UiO@UiO2-N3-aptamer) with a high aptamer coverage density was proposed based on the electrospinning and seeded growth method, and used for specific affinity recognition of trace Microcystin-LR (MC-LR). Heterobifunctional ligand was used to modify the metal-organic framework nanoparticles (MOF NPs) surface, which could passivate the MOF surface with respect to unmodified DNA, followed by coupling massive aptamers on MOF of the solid-phase microextraction (SPME) fiber using click chemistry. Characterizations including morphology, spectra analysis, mechanical stability, binding capacity and specificity were fulfilled. Applied to the analysis of MC-LR, the good selective and sensitive recognition were obtained with the detection limit as low as 0.003 ng/mL, which was better than most non-specific SPME or solid-phase extraction (SPE) protocols. The stability and reproducibility were acceptable, and the intra-day, inter-day and column-to-column relative standard deviations (RSDs) for the recovery of MC-LR were gained in the range from 2.5% to 14.3%, respectively. Satisfactory recoveries of MC-LR in environmental water samples were measured as 96.3 ± 4.7% - 98.9 ± 2.7% (n = 3) in tap water, 94.4 ± 2.5% - 96.1 ± 3.5% (n = 3) in pond water, and 97.0 ± 2.1% - 97.9 ± 3.1% (n = 3) in river water, respectively. This work demonstrated that the electrospun nanofibrous composite with massive aptamers would be a better alternative for ultra-trace MC-LR detection with good selectivity, matrix-resistance ability and high resolution.
Collapse
Affiliation(s)
- Zhiqun Xu
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Zhexiang Zhang
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Zongkang She
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Chenchen Lin
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Xucong Lin
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China; Engineering Technology Research Center on Reagent and Instrument for Rapid Detection of Product Quality and Food Safety, Fujian, Fuzhou, 350108, People's Republic of China.
| | - Zenghong Xie
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China; Engineering Technology Research Center on Reagent and Instrument for Rapid Detection of Product Quality and Food Safety, Fujian, Fuzhou, 350108, People's Republic of China
| |
Collapse
|
15
|
Poddar S, Sharmeen S, Hage DS. Affinity monolith chromatography: A review of general principles and recent developments. Electrophoresis 2021; 42:2577-2598. [PMID: 34293192 PMCID: PMC9536602 DOI: 10.1002/elps.202100163] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 07/07/2021] [Accepted: 07/18/2021] [Indexed: 12/28/2022]
Abstract
Affinity monolith chromatography (AMC) is a liquid chromatographic technique that utilizes a monolithic support with a biological ligand or related binding agent to isolate, enrich, or detect a target analyte in a complex matrix. The target-specific interaction exhibited by the binding agents makes AMC attractive for the separation or detection of a wide range of compounds. This article will review the basic principles of AMC and recent developments in this field. The supports used in AMC will be discussed, including organic, inorganic, hybrid, carbohydrate, and cryogel monoliths. Schemes for attaching binding agents to these monoliths will be examined as well, such as covalent immobilization, biospecific adsorption, entrapment, molecular imprinting, and coordination methods. An overview will then be given of binding agents that have recently been used in AMC, along with their applications. These applications will include bioaffinity chromatography, immunoaffinity chromatography, immobilized metal-ion affinity chromatography, and dye-ligand or biomimetic affinity chromatography. The use of AMC in chiral separations and biointeraction studies will also be discussed.
Collapse
Affiliation(s)
- Saumen Poddar
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, 68588, USA
| | - Sadia Sharmeen
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, 68588, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, 68588, USA
| |
Collapse
|
16
|
Hong T, Liu X, Zhou Q, Liu Y, Guo J, Zhou W, Tan S, Cai Z. What the Microscale Systems "See" In Biological Assemblies: Cells and Viruses? Anal Chem 2021; 94:59-74. [PMID: 34812604 DOI: 10.1021/acs.analchem.1c04244] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Tingting Hong
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu 213164, China
| | - Xing Liu
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu 213164, China
| | - Qi Zhou
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu 213164, China
| | - Yilian Liu
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu 213164, China
| | - Jing Guo
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu 213164, China
| | - Wenhu Zhou
- Xiangya School of Pharmaceutical Sciences, Central South University, 172 Tongzipo Road, Changsha, Hunan 410013, China
| | - Songwen Tan
- Xiangya School of Pharmaceutical Sciences, Central South University, 172 Tongzipo Road, Changsha, Hunan 410013, China.,Jiangsu Dawning Pharmaceutical Co., Ltd., Changzhou, Jiangsu 213100, China
| | - Zhiqiang Cai
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu 213164, China.,Jiangsu Dawning Pharmaceutical Co., Ltd., Changzhou, Jiangsu 213100, China
| |
Collapse
|
17
|
Zhao T, Zhang M, Peng Q, Lin X, Xie Z. Facile DNA adsorption enabling ammonium-based hydrophilic affinity monolithic column for high-performance online selective microextraction of ochratoxin A. Anal Chim Acta 2021; 1185:339077. [PMID: 34711314 DOI: 10.1016/j.aca.2021.339077] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Revised: 09/09/2021] [Accepted: 09/15/2021] [Indexed: 11/30/2022]
Abstract
Herein, a facile protocol of simple DNA adsorption on UV-initiated polymerization supports was proposed for effectively fabricating aptamer-based affinity monolithic column. Hydrophilic cationic monolith with an excellent mechanical stability was achieved within 7 min and then massive aptamers were directly bound by DNA charge-dependent adsorption. Strong cationic quaternary ammonium-based monomer was employed to provide effective and stable positive charge surface for aptamer immobilization in a wide range of pH. An ultra-high aptamer coverage density of 6813 pmol/μL was achieved to gain a highly specific online recognition performance. Limitations such as low aptamer capacity, tedious modification and time-consuming reactions in the traditional biological or covalent modification strategies were avoided. By using ochratoxin A (OTA) as the given analyte, the selective recognition and high recoveries were successfully achieved, and little cross-reactivity towards OTB analogue was only 0.5% even if the content of OTB got up to 125 folds of OTA. Applied to sample analysis, the satisfactory discriminations of trace OTA were obtained at 93.9 ± 1.9% - 96.5 ± 1.7%(n = 3)in beer, wheat and chicken liver samples. It might light a cost-effective access to efficiently preparing high-performance affinity monoliths towards the selective in-tube microextraction of OTA.
Collapse
Affiliation(s)
- Tingting Zhao
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Min Zhang
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Qi Peng
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Xucong Lin
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China.
| | - Zenghong Xie
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China
| |
Collapse
|
18
|
Xu Z, Fan G, Zheng T, Lin C, Lin X, Xie Z. Aptamer-functionalized metal-organic framework-based electrospun nanofibrous composite coating fiber for specific recognition of ultratrace microcystin in water. J Chromatogr A 2021; 1656:462542. [PMID: 34543883 DOI: 10.1016/j.chroma.2021.462542] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2021] [Revised: 08/23/2021] [Accepted: 09/04/2021] [Indexed: 02/01/2023]
Abstract
A novel aptamer@AuNPs@UiO-66-NH2 electrospun nanofibrous coating fiber for specific recognition of microcystin-LR (MC-LR) was proposed by using electrospinning, metal-organic frameworks (MOF) seed growth and AuNPs bridging aptamer strategies. Characterization of morphology, structure and stability of the obtained affinity nanofibrous coating fiber were investigated. High loading of MOFs and aptamers on the nanofibrous fiber were achieved and successfully applied for accurate identification of MC-LR by solid-phase microextraction (SPME) coupled with LC-MS. Highly specific recognition of MC-LR with little interference of analogs was achieved with extremely low LOD (0.004 ng/mL), good precision (CV% < 11.0%) and low relative error (RE% = -1.5% to -10.0%), which was rather better than that of the traditional SPME or SPE protocols. Satisfactory recoveries of MC-LR were obtained in the range of 92.0-96.8% (n = 3) in fortified tap water, raw pond water and river water samples. This work revealed an attractive alternative access to specific recognition and super-sensitive analysis of MC-LR in water.
Collapse
Affiliation(s)
- Zhiqun Xu
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou 350108, People's Republic of China
| | - Guanghui Fan
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou 350108, People's Republic of China
| | - Tuo Zheng
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou 350108, People's Republic of China
| | - Chenchen Lin
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou 350108, People's Republic of China
| | - Xucong Lin
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou 350108, People's Republic of China; Engineering Technology Research Center on Reagent and Instrument for Rapid Detection of Product Quality and Food Safety, Fuzhou, Fujian 350108, People's Republic of China.
| | - Zenghong Xie
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou 350108, People's Republic of China; Engineering Technology Research Center on Reagent and Instrument for Rapid Detection of Product Quality and Food Safety, Fuzhou, Fujian 350108, People's Republic of China
| |
Collapse
|
19
|
Recent advances in analysis of bisphenols and their derivatives in biological matrices. Anal Bioanal Chem 2021; 414:807-846. [PMID: 34652496 DOI: 10.1007/s00216-021-03668-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Accepted: 09/14/2021] [Indexed: 10/20/2022]
Abstract
Biomonitoring is a very useful tool to evaluate human exposure to endocrine-disrupting compounds (EDCs), like bisphenols (BPs), which are widely used in the manufacture of plastics. The development of reliable analytical methods is key in the field of public health surveillance to obtain biomonitoring data to determine what BPs are reaching people's bodies. This review discusses recent methods for the quantitative measurement of bisphenols and their derivatives in biological samples like urine, blood, breast milk, saliva, and hair, among others. We also discuss the different procedures commonly used for sample treatment, which includes extraction and clean-up, and instrumental techniques currently used to determine these compounds. Sample preparation techniques continue to play an important role in the analysis of complex matrices, for liquid matrices the most commonly employed is solid-phase extraction, although microextraction techniques are gaining importance in this field, and for solid samples ultrasound-assisted extraction. The main instrumental techniques used are liquid and gas chromatography coupled with mass spectrometry. Finally, we present data on the main parameters obtained in the validation of the revised methods. This review focuses on various methods developed and applied for trace analysis of bisphenols, their conjugates, halogenated derivatives, and diglycidyl ethers in biological samples to enable the required selectivity and sensitivity. For this purpose, a review is carried out of the most recent relevant publications from 2016 up to present.
Collapse
|
20
|
Zhao T, Ding X, Lin C, Lin X, Xie Z. In situ photo-initiated polymerized oligonucleotide-functionalized hydrophilic capillary affinity monolith for highly selective in-tube microextraction of ochratoxin A mycotoxin. Mikrochim Acta 2021; 188:341. [PMID: 34523048 DOI: 10.1007/s00604-021-04997-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Accepted: 08/23/2021] [Indexed: 11/24/2022]
Abstract
A photo-initiated polymerized oligonucleotide-grafted hydrophilic affinity monolithic column was synthesized in situ, and exploited for selective in-tube solid phase micro-extraction (IT-SPME) protocol towards the sensitive detection of ochratoxin A (OTA). Only 7 min was required for the rapid polymerization of aptamer-based affinity monolith, which was much less than the reaction time of most thermal polymerization (12-16 h) and sol-gel chemistry methods (up to 52 h). Characterizations such as polymerization recipes, structure morphology, FTIR spectrum, elemental mapping, mechanical stability, and specific recognition performance were evaluated. A significantly hydrophilic nature with a low contact angle of 15° was observed, and a mixed-mode mechanism including aptamer affinity recognition and hydrophilic interaction (HI) was employed. By coupling with HPLC-fluorescence detection, the highly specific online recognition performance was achieved with an extremely low nonspecific adsorption of the analogues. The calibration curve of OTA was obtained in the concentration range 0.05-50.00 ng·mL-1 with a limit of detection (LOD, S/N = 3) of 0.012 ng·mL-1. Applied to sample analysis, acceptable recovery yields of 95.1 ± 1.4% - 99.5 ± 2.2% (n = 3) were obtained in beer and red wine. The proposed method lighted a promising way to efficiently preparing a hydrophilic aptamer-affinity monolith for highly specific recognition of trace mycotoxin by IT-SPME coupled with HPLC. A hydrophilic oligonucleotide-based affinity capillary monolith was explored via in situ photopolymerization for overcoming low preparation efficiency and achieving high-performance online IT-SPME of OTA mycotoxin.
Collapse
Affiliation(s)
- Tingting Zhao
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Xinyue Ding
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Chenchen Lin
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Xucong Lin
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China.
| | - Zenghong Xie
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China
| |
Collapse
|
21
|
Zhao T, Tong S, Zhou S, Lin C, Lin X, Xie Z. A facile aptamer immobilization strategy to fabricate a robust affinity monolith for highly specific in-tube solid-phase microextraction. Analyst 2021; 146:5732-5739. [PMID: 34515698 DOI: 10.1039/d1an00993a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Developing a functional affinity monolithic column towards in-tube solid-phase microextraction (IT-SPME) for selective sample pretreatment is critical. Herein, a high-performance capillary affinity monolithic column with an ultra-high aptamer coverage density was rapidly fabricated via a simple adsorption strategy, in which aptamers with natural sequences were directly immobilized on an ammonium-based strongly cationic matrix. Limitations of the traditional biological or covalent methods such as time-consuming modification reactions, special requirement of active groups (e.g. -NH2 and -SH) on the aptamer, and low aptamer coverage density levels were avoided. An ultra-high coverage density of 8616 pmol μL-1 was achieved with excellent stability, and the highest aptamer-modification level among all the current methods was reached. Selective recognition and high recovery yields of the model mycotoxin ochratoxin A (OTA) were achieved in 95.9 ± 0.98%-97.9 ± 0.28% (n = 3). In particular, there was little cross-reactivity towards the OTB analogue of only 0.5% even in the case of 250 fold of the analogue OTB, which was not reported in previous affinity monoliths. Upon sample analysis, satisfactory discriminations of trace OTA were obtained at 93.7 ± 1.4%-95.5 ± 2.5% (n = 3) in beer and wheat. A facile and direct method for efficiently fabricating an aptamer-based affinity monolith towards online selective IT-SPME was proposed.
Collapse
Affiliation(s)
- Tingting Zhao
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, P.R. China.
| | - Shiqian Tong
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, P.R. China.
| | - Susu Zhou
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, P.R. China.
| | - Chenchen Lin
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, P.R. China.
| | - Xucong Lin
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, P.R. China. .,Engineering Technology Research Center on Reagent and Instrument for Rapid Detection of Product Quality and Food Safety, Fujian, Fuzhou, 350108, P.R. China
| | - Zenghong Xie
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, P.R. China. .,Engineering Technology Research Center on Reagent and Instrument for Rapid Detection of Product Quality and Food Safety, Fujian, Fuzhou, 350108, P.R. China
| |
Collapse
|
22
|
Zhao T, Ding X, Chen Y, Lin C, Qi G, Lin X, Xie Z. Towards highly specific aptamer-affinity monolithic column by efficient UV light-initiated polymerization in "one-pot". Anal Chim Acta 2021; 1165:338517. [PMID: 33975695 DOI: 10.1016/j.aca.2021.338517] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 04/03/2021] [Accepted: 04/12/2021] [Indexed: 01/08/2023]
Abstract
Time-consuming or tedious operation in multiple-step process might is the obstacle for efficiently preparing aptamer-affinity monolithic column. Here, a new and facile strategy to prepare aptamer-based hybrid affinity monolith in "one-pot" at room temperature was exploited, in which UV light-initiated free-radical polymerization and "thiol-ene" click reaction were implemented simultaneously. Only 7 min was cost for finishing the polymerization reaction, which was only 1/100 of that for the traditional thermal polymerization. Using ochratoxin A (OTA) as the model analyte, the recipe for photo-initiated polymerization was optimized, and SEM morphology, FTIR, EDS, pore size distribution and specific recognition performance were also studied. Compared with traditional thermal polymerization, the resultant monolith was achieved more facilely and displayed better results such as more homogeneous skeleton structure, higher reaction efficiency of aptamer (>88.2%) and better specific selectivity to OTA. Besides, an extremely low nonspecific adsorption of analogues was obtained and showed a level at only 1/25 of that in the similar aptamer-affinity monolith prepared by thermal polymerization. Applied to beer and red wine samples, good recovery yields about 99.7 ± 4.0% -101.2 ± 2.3% (n = 3)was achieved with the acceptable RSDs. It would open up a rapid and promising access to efficiently preparing high-performance aptamer-based affinity monolithic columns for online specific recognition.
Collapse
Affiliation(s)
- Tingting Zhao
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Xinyue Ding
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Yiqiong Chen
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Chenchen Lin
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Guomin Qi
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Xucong Lin
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China; Engineering Technology Research Center on Reagent and Instrument for Rapid Detection of Product Quality and Food Safety, Fujian, Fuzhou, 350108, People's Republic of China.
| | - Zenghong Xie
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China; Engineering Technology Research Center on Reagent and Instrument for Rapid Detection of Product Quality and Food Safety, Fujian, Fuzhou, 350108, People's Republic of China
| |
Collapse
|
23
|
Lu F, Lin J, Lin C, Qi G, Lin X, Xie Z. Heteroporous 3D covalent organic framework-based magnetic nanospheres for sensitive detection of bisphenol A. Talanta 2021; 231:122343. [PMID: 33965019 DOI: 10.1016/j.talanta.2021.122343] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2020] [Revised: 03/07/2021] [Accepted: 03/18/2021] [Indexed: 11/25/2022]
Abstract
Covalent organic frameworks (COFs) showed great promise in effective adsorption of target molecule via size selectivity. Although various magnetic 2D COFs composites have been studied and exhibited the intensive applications, the incorporation of 3D COFs and magnetic nanoparticles to form a new class of magnetic adsorbents with enhanced function still has no reports. Herein, a novel Fe3O4@3D COF with heteroporous structure matching to the sizes of bisphenol A (BPA) was firstly synthesized for better adsorption of BPA than common magnetic 2D-COFs. Three Fe3O4@3D COFs nanospheres were synthesized under the solvothermal conditions in autoclave, and the optimum Fe3O4@3D-COF denoted as Fe3O4@COF-TpTAM (Tp, 1,3,5-triformylphloroglucinol; TAM, tetra(p-aminophenyl)-methane) was selected and employed. Detailed characteristics of Fe3O4@COF-TpTAM were evaluated via various techniques including TEM, FTIR, TGA, XRD and BET. Excellent chemical and thermal stability, high surface area (294.6 m2 g-1) and pore volume (0.2 m3 g-1) with multiple pore sizes comparable with the simulated three-dimensional sizes of BPA were exhibited. A high adsorption capacity of BPA up to 209.9 mg/g that was better than common 2D-COFs was achieved, and the sensitive MSPE-LC-MS method with wide linear range (10-5000 pg/mL), low detection limit (4 pg/mL, S/N = 3) was built. Satisfactory recoveries of BPA as 93.8 ± 1.4%-101.4 ± 5.1% (n = 3) and 100.4 ± 1.9% ~ 107.3 ± 1.2% (n = 3) were obtained in milk and river water samples, respectively. This work demonstrates the promising application of Fe3O4@3D COF as efficient adsorbents of trace BPA, and opens up a new access for the efficient MSPE in sample pretreatment for food or environmental safety analysis.
Collapse
Affiliation(s)
- Feifei Lu
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, China
| | - Jian Lin
- Forensic Science Division, Fujian Provincial Department of Public Security, Fuzhou, China
| | - Chenchen Lin
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, China
| | - Guomin Qi
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, China
| | - Xucong Lin
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, China.
| | - Zenghong Xie
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, China
| |
Collapse
|
24
|
Zhou Y, Duan L, Huang Y, Liu Y, Wang L, Qiao X. Ionic Liquid 1-Vinyl-3-dodecylimidazole Bromide Embedded Hybrid Monolithic Column and Its Versatile Post-modification with Amino Acids. JOURNAL OF ANALYSIS AND TESTING 2021. [DOI: 10.1007/s41664-021-00171-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
25
|
Jia XX, Li S, Han DP, Chen RP, Yao ZY, Ning BA, Gao ZX, Fan ZC. Development and perspectives of rapid detection technology in food and environment. Crit Rev Food Sci Nutr 2021; 62:4706-4725. [PMID: 33523717 DOI: 10.1080/10408398.2021.1878101] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Food safety become a hot issue currently with globalization of food trade and food supply chains. Chemical pollution, microbial contamination and adulteration in food have attracted more attention worldwide. Contamination with antibiotics, estrogens and heavy metals in water environment and soil environment have also turn into an enormous threat to food safety. Traditional small-scale, long-term detection technologies have been unable to meet the current needs. In the monitoring process, rapid, convenient, accurate analysis and detection technologies have become the future development trend. We critically synthesizing the current knowledge of various rapid detection technology, and briefly touched upon the problem which still exist in research process. The review showed that the application of novel materials promotes the development of rapid detection technology, high-throughput and portability would be popular study directions in the future. Of course, the ultimate aim of the research is how to industrialization these technologies and apply to the market.
Collapse
Affiliation(s)
- Xue-Xia Jia
- Institute of Environmental and Operational Medicine, Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin, P.R. China.,State Key Laboratory of Food Nutrition and Safety, China International Scientific & Technological Cooperation Base for Health Biotechnology, College of Food Engineering and Biotechnology, Tianjin University of Science & Technology, Tianjin, P.R. China
| | - Shuang Li
- Institute of Environmental and Operational Medicine, Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin, P.R. China
| | - Dian-Peng Han
- Institute of Environmental and Operational Medicine, Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin, P.R. China
| | - Rui-Peng Chen
- Institute of Environmental and Operational Medicine, Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin, P.R. China
| | - Zi-Yi Yao
- Institute of Environmental and Operational Medicine, Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin, P.R. China
| | - Bao-An Ning
- Institute of Environmental and Operational Medicine, Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin, P.R. China
| | - Zhi-Xian Gao
- Institute of Environmental and Operational Medicine, Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin, P.R. China
| | - Zhen-Chuan Fan
- State Key Laboratory of Food Nutrition and Safety, China International Scientific & Technological Cooperation Base for Health Biotechnology, College of Food Engineering and Biotechnology, Tianjin University of Science & Technology, Tianjin, P.R. China
| |
Collapse
|
26
|
Exploring the Ability of Luminescent Metal Assemblies to Bind and Sense Anionic or Ionizable Analytes A Ru(phen) 2bipy-Based Dizinc Complex for Bisphenol A (BPA) Recognition. Molecules 2021; 26:molecules26030527. [PMID: 33498435 PMCID: PMC7864177 DOI: 10.3390/molecules26030527] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 01/14/2021] [Accepted: 01/17/2021] [Indexed: 12/17/2022] Open
Abstract
The synthesis of a new RuII complex, in which the metal is coordinated by two 1,10-phenanthroline ligands and a 2,2′-bipyridyl unit linked, via methylene bridges in its 4 and 4′ positions, to two 1,4,7,10-tetraazacyclododecane (cyclen) macrocycles ([Ru(phen)2L]2+) is reported. Protonation and ZnII binding by [Ru(phen)2L]2+ have been analyzed by potentiometric titration, evidencing the formation of mixed hetero-binuclear and hetero-trinuclear ZnII/RuII complexes. These complexes were tested as bis-phenol A (BPA) binders. Only the dizinc complex with [Ru(phen)2L]2+ is able to bind BPA in aqueous solution, affording a remarkably stable {Zn2[Ru(phen)2L]BPA(H−2)}4+ adduct at neutral pH, in which BPA is bound in its doubly deprotonated form to the two ZnII ions. BPA binding was found to quench the luminescence emission of the RuII(phen)2bipy core. Although the quenching effect is modest, this study demonstrates that appropriately designed dizinc complexes can be used for binding and optical sensing of BPA in water.
Collapse
|