1
|
Moghaddam AZ, Arabi E, Shakourian-Fard M. SPE of gallic acid and ascorbic acid in fruits using polymerized deep eutectic solvent-modified substrate. Bioanalysis 2023; 15:1221-1233. [PMID: 37724473 DOI: 10.4155/bio-2023-0093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/20/2023] Open
Abstract
Aim: Novel substrates were synthesized by porous and nonporous polymerization of deep eutectic solvents on magnetic silica nanoparticles and introduced for dispersive solid-phase extraction of two analytes. Materials & methods: The prepared substrates were characterized, and an extraction procedure was implemented to select the best substrates and eluent. The central composite design acted to optimize the effects of parameters that influenced the extraction efficiencies. Results: For gallic and ascorbic acids, the limits of detection were obtained at 0.136 and 0.165 μM, respectively, with linear ranges of 0.6-125.2 and 0.5-106.8 μM, respectively. Conclusion: The substrate produced good extractions even after being used three-times and was successfully applied for the analysis of real samples.
Collapse
Affiliation(s)
- Ali Zeraatkar Moghaddam
- Department of Chemistry, Faculty of Science, University of Birjand, Birjand, South Khorasan, PO Box 97175/615, Iran
| | - Elahe Arabi
- Department of Chemistry, Faculty of Science, University of Birjand, Birjand, South Khorasan, PO Box 97175/615, Iran
| | - Mehdi Shakourian-Fard
- Department of Chemical Engineering, Birjand University of Technology, Birjand, South Khorasan, PO Box 97175/569, Iran
| |
Collapse
|
2
|
Rahbarian H, Nojavan S, Maghsoudi M, Tabani H. In-tube gel electromembrane extraction: A green strategy for the extraction of narcotic drugs from biological samples. J Chromatogr A 2023; 1688:463714. [PMID: 36565655 DOI: 10.1016/j.chroma.2022.463714] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 12/09/2022] [Accepted: 12/10/2022] [Indexed: 12/14/2022]
Abstract
The development of green and miniature extraction methods is always a major and controversial challenge in the field of sample preparation. In this work, in-tube gel electromembrane extraction (IT-G-EME) was developed as a miniaturized extraction device for the extraction of six narcotic drugs (codeine, oxycodone, hydrocodone, tramadol, thebaine, and noscapine) from biological samples. A transparent capillary tube (∼6 cm) was used as a microextraction unit. The middle part of the tube was filled with a narrow plug (∼3 mm) of the agarose gel (3.0% w/v) as a membrane and the other sides were filled with aqueous extractant solution (pH 2.0, 20 µL) and sample solution (pH 5.0, 200 µL). By applying electrical potential (400 V), the target drugs with positive charge were migrated from sample solution toward the extractant solution through gel membrane during short extraction time (5 min). Then, the enriched analytes in extractant solution was analyzed by HPLC-UV. Under the optimized conditions, the calibration curves were linear within the permissible range of 10.0-1500 ng/mL (r2 ≥ 0.991). Limits of detection and extraction recoveries were in the range of 3.0-4.5 ng/mL and 61.9-86.9%, respectively. On the basis of four replications, the repeatability of the method was also evaluated in terms of intra- and inter-day RSDs (%), which did not exceed from 6.6 and 7.9%, respectively in aqueous media. The figures of merit were also assessed in biological samples. Eventually, the developed method was profitably used for simultaneous determination of narcotic drugs in the real urine and plasma samples.
Collapse
Affiliation(s)
- Hanieh Rahbarian
- Department of Analytical Chemistry and Pollutants, Shahid Beheshti University, Evin, Tehran, Iran
| | - Saeed Nojavan
- Department of Analytical Chemistry and Pollutants, Shahid Beheshti University, Evin, Tehran, Iran.
| | - Majid Maghsoudi
- Department of Analytical Chemistry and Pollutants, Shahid Beheshti University, Evin, Tehran, Iran
| | - Hadi Tabani
- Department of Environmental Geology, Research Institute of Applied Sciences (ACECR), Shahid Beheshti University, Tehran, Iran.
| |
Collapse
|
3
|
Green bioanalysis: an innovative and eco-friendly approach for analyzing drugs in biological matrices. Bioanalysis 2022; 14:881-909. [PMID: 35946313 DOI: 10.4155/bio-2022-0095] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Green bioanalytical techniques aim to reduce or eliminate the hazardous waste produced by bioanalytical technologies. A well-organized and practical approach towards bioanalytical method development has an enormous contribution to the green analysis. The selection of the appropriate sample extraction process, organic mobile phase components and separation technique makes the bioanalytical method green. UHPLC-MS is the best option, whereas supercritical fluid chromatography is one of the most effective green bioanalytical procedures. Nevertheless, there remains excellent scope for further research on green bioanalytical methods. This review details the various sample preparation techniques that follow green analytical chemistry principles. Furthermore, it presents green solvents as a replacement for conventional organic solvents and highlights the strategies to convert modern analytical techniques to green methods.
Collapse
|
4
|
|
5
|
Eie LV, Pedersen-Bjergaard S, Hansen FA. Electromembrane extraction of polar substances - Status and perspectives. J Pharm Biomed Anal 2022; 207:114407. [PMID: 34634529 DOI: 10.1016/j.jpba.2021.114407] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 09/20/2021] [Accepted: 09/30/2021] [Indexed: 12/15/2022]
Abstract
In this article, the scientific literature on electromembrane extraction (EME) of polar substances (log P < 2) is reviewed. EME is an extraction technique based on electrokinetic migration of analyte ions from an aqueous sample, across an organic supported liquid membrane (SLM), and into an aqueous acceptor solution. Because extraction is based on voltage-assisted partitioning, EME is fundamentally suitable for extraction of polar and ionizable substances that are challenging in many other extraction techniques. The article provides an exhaustive overview of papers on EME of polar substances. From this, different strategies to improve the mass transfer of polar substances are reviewed and critically discussed. These strategies include different SLM chemistries, modification of supporting membranes, sorbent additives, aqueous solution chemistry, and voltage/current related strategies. Finally, the future applicability of EME for polar substances is discussed. We expect EME in the coming years to be developed towards both very selective targeted analysis, as well as untargeted analysis of polar substances in biomedical applications such as metabolomics and peptidomics.
Collapse
Affiliation(s)
- Linda Vårdal Eie
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway
| | - Stig Pedersen-Bjergaard
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway; Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark
| | - Frederik André Hansen
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway.
| |
Collapse
|
6
|
Gomes RDS, Thesing A, Santos JFL, Fernandes AN. Self-supported 3D reduced graphene oxide for solid-phase extraction: An efficient and low-cost sorbent for environmental contaminants in aqueous solution. Talanta 2021; 235:122750. [PMID: 34517618 DOI: 10.1016/j.talanta.2021.122750] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Revised: 07/27/2021] [Accepted: 07/28/2021] [Indexed: 10/20/2022]
Abstract
A 3D reduced graphene oxide (3D-rGO), a self-supported, efficient, and low-cost sorbent, was synthesised and employed in a solid-phase extraction (SPE) cartridge. As a proof of concept, it was applied to remove diclofenac from aqueous solution. After applying statistical methods to systematically investigate key parameters for optimizing the 3D-rGO cartridge performance, it reached removal and elution efficiencies of 100 % and 90 %, respectively. This SPE cartridge presented advantages compared to traditional ones as the smaller amount of material into the cartridge (mass twenty times smaller), in addition to the ability of eliminating sorbent preconditioning, reducing the use of solvents, and making the process environmentally friendly with a faster operation. Also, it presented improved reproducibility after several cycles of reuse, and finally a lower cost of production unveiled by a cost-benefit analysis. Analysis with scanning electron microscopy, X-ray diffraction, X-ray photoelectron spectrometry, Raman, and Fourier transform infrared spectroscopy in attenuated total reflectance mode suggested that the 3D framework morphology with a high content of carbon at the surface and some residual oxygen-containing groups are the protagonists in this performance. Therefore, 3D-rGO has the potential to be a highly efficient sorbent in analytical procedures using SPE for environmental contaminants in water and effluent samples.
Collapse
Affiliation(s)
- Raimara de Souza Gomes
- Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves, 9500, Bairro Agronomia, Porto Alegre, RS, 91501-970, Brazil
| | - Anderson Thesing
- Instituto de Física, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves, 9500, Bairro Agronomia, Porto Alegre, RS, 91501-970, Brazil
| | - Jacqueline Ferreira Leite Santos
- Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves, 9500, Bairro Agronomia, Porto Alegre, RS, 91501-970, Brazil.
| | - Andreia Neves Fernandes
- Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves, 9500, Bairro Agronomia, Porto Alegre, RS, 91501-970, Brazil.
| |
Collapse
|
7
|
Li Z, Chen B, Liang C, Li N, Zhao Y, Dong C. The Effect of Flow-Induced Vibration on Heat and Mass Transfer Performance of Hollow Fiber Membranes in the Humidification/Dehumidification Process. MEMBRANES 2021; 11:membranes11120918. [PMID: 34940420 PMCID: PMC8707744 DOI: 10.3390/membranes11120918] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Accepted: 11/15/2021] [Indexed: 11/16/2022]
Abstract
Cross-flow hollow fiber membranes are commonly applied in humidification/dehumidification. Hollow fiber membranes vibrate and deform under the impinging force of incoming air and the gravity of liquid in the inner tube. In this study, fiber deformation was caused by the pulsating flow of air. With varied pulsating amplitudes and frequencies, single-fiber deformation was investigated numerically using the fluid–structure interaction technique and verified with experimental data testing with a laser vibrometer. Then, the effect of pulsating amplitude and frequency on heat and mass transfer performance of the hollow fiber membrane was analyzed. The maximum fiber deformation along the airflow direction was far larger than that perpendicular to the flow direction. Compared with the case where the fiber did not vibrate, increasing the pulsation amplitude could strengthen Nu by 14–87%. Flow-induced fiber vibration could raise the heat transfer enhancement index from 13.8% to 80%. The pulsating frequency could also enhance the heat transfer of hollow fiber membranes due to the continuously weakened thermal boundary layer. With the increase in pulsating amplitude or frequency, the Sh number or Em under vibrating conditions can reach about twice its value under non-vibrating conditions.
Collapse
Affiliation(s)
- Zhenxing Li
- School of Mechanical and Electrical Engineering, Guilin University of Electronic Technology, Guilin 541004, China; (Z.L.); (B.C.); (N.L.)
| | - Bo Chen
- School of Mechanical and Electrical Engineering, Guilin University of Electronic Technology, Guilin 541004, China; (Z.L.); (B.C.); (N.L.)
| | - Caihang Liang
- School of Mechanical and Electrical Engineering, Guilin University of Electronic Technology, Guilin 541004, China; (Z.L.); (B.C.); (N.L.)
- Guangdong Province Key Laboratory of Distributed Energy System, Guangdong Provincial Engineering Research Center of Distributed Energy Systems, Dongguan University of Technology, Dongguan 523808, China
- Correspondence: ; Tel.: +86-773-229-2386
| | - Nanfeng Li
- School of Mechanical and Electrical Engineering, Guilin University of Electronic Technology, Guilin 541004, China; (Z.L.); (B.C.); (N.L.)
| | - Yunyun Zhao
- School of Materials Science and Engineering, Guilin University of Electronic Technology, Guilin 541004, China;
| | - Chuanshuai Dong
- Key Laboratory of Enhanced Heat Transfer and Energy Conservation of Education Ministry, School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou 510641, China;
| |
Collapse
|
8
|
A low-voltage electro-membrane extraction for quantification of imatinib and sunitinib in biological fluids. Bioanalysis 2021; 13:1401-1413. [PMID: 34517777 DOI: 10.4155/bio-2021-0138] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Aim: Hollow-fiber-based supported liquid membrane was modified utilizing nanostructures such as graphite, graphene oxide or nitrogen-doped graphene oxide, for electro-membrane extraction (EME) of imatinib and sunitinib from biological fluids. By applying these conductive nanostructures, a low-voltage EME device (6.0 V) was fabricated. Materials & methods: A response surface methodology through central composite design was used to evaluate and optimize effects of various essential factors that influence on normalized recovery. Results: Optimal extraction conditions were set as, 1-octanol with 0.01 % (w/v) graphene oxide functioning as the supported liquid membrane, an extraction time of 17.0 min, pH of the acceptor and the donor phase of 2.8 and 7.9, respectively. Conclusion: The method was successfully applied to quantify imatinib and sunitinib in biological fluids.
Collapse
|
9
|
An overview on the recent applications of agarose as a green biopolymer in micro-extraction-based sample preparation techniques. Talanta 2021; 224:121892. [DOI: 10.1016/j.talanta.2020.121892] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2020] [Revised: 11/10/2020] [Accepted: 11/11/2020] [Indexed: 12/19/2022]
|