1
|
Luo K, Zhao L, Liu Y, Zhang Y, Chen W, Tang S. Hydrophobic/hydrophilic separation performance evaluation of a mixed-mode ionic liquid embedded stearyl thioglycolate functionalized silica stationary phase. J Chromatogr A 2023; 1706:464279. [PMID: 37567003 DOI: 10.1016/j.chroma.2023.464279] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 08/02/2023] [Accepted: 08/03/2023] [Indexed: 08/13/2023]
Abstract
In this work, a novel imidazolium ionic liquid embedded multifunctional chromatographic stationary phase (Sil-AVI-ST) was synthesized by the radical-mediated thiol-ene click reaction. A wide range of samples including hydrophilic sulfonamides, vitamins and nucleosides/bases as well as hydrophobic phthalates, bisphenols, alkylphenols and steroid hormones were selected to evaluate the separation ability of the newly obtained Sil-AVI-ST. As expected, an efficient separation of the above tested analytes was successfully achieved in different chromatographic modes. It was proved that multiple stationary phase-analyte interaction forces promoted the selective separation. The Sil-AVI-ST column provided multiple retention mechanisms, enabling the efficient separation of diverse analytes with different polarity. More importantly, embedding a polar ligand (1-allyl-3-vinyl-imidazolium) could improve the separation efficiency of long-chain alkyl bonded stationary phases for hydrophilic analytes, and the developed Sil-AVI-ST column could also realize the detection of hydrophobic analytes under water-rich conditions, which is impossible for the conventional hydrophobic columns. Therefore, the newly prepared Sil-AVI-ST stationary phase has a good practical application potential.
Collapse
Affiliation(s)
- Kaixing Luo
- School of Chemistry and Environmental Engineering, Key Laboratory of Green Chemical Process of Ministry of Education, Hubei Key Laboratory of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan 430205, China
| | - Lulu Zhao
- School of Chemistry and Environmental Engineering, Key Laboratory of Green Chemical Process of Ministry of Education, Hubei Key Laboratory of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan 430205, China
| | - Yanjuan Liu
- School of Pharmacy, Linyi University, Shuangling Road, Linyi 276000, Shandong, China
| | - Yuefei Zhang
- School of Chemistry and Environmental Engineering, Key Laboratory of Green Chemical Process of Ministry of Education, Hubei Key Laboratory of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan 430205, China
| | - Wei Chen
- School of Chemistry and Environmental Engineering, Key Laboratory of Green Chemical Process of Ministry of Education, Hubei Key Laboratory of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan 430205, China
| | - Sheng Tang
- School of Chemistry and Environmental Engineering, Key Laboratory of Green Chemical Process of Ministry of Education, Hubei Key Laboratory of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan 430205, China.
| |
Collapse
|
2
|
Borsatto JVB, Lanças FM. Recent Trends in Graphene-Based Sorbents for LC Analysis of Food and Environmental Water Samples. Molecules 2023; 28:5134. [PMID: 37446796 DOI: 10.3390/molecules28135134] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 06/22/2023] [Accepted: 06/22/2023] [Indexed: 07/15/2023] Open
Abstract
This review provides an overview of recent advancements in applying graphene-based materials as sorbents for liquid chromatography (LC) analysis. Graphene-based materials are promising for analytical chemistry, including applications as sorbents in liquid chromatography. These sorbents can be functionalized to produce unique extraction or stationary phases. Additionally, graphene-based sorbents can be supported in various materials and have consequently been applied to produce various devices for sample preparation. Graphene-based sorbents are employed in diverse applications, including food and environmental LC analysis. This review summarizes the application of graphene-based materials in food and environmental water analysis in the last five years (2019 to 2023). Offline and online sample preparation methods, such as dispersive solid phase microextraction, stir bar sorptive extraction, pipette tip solid phase extraction, in-tube solid-phase microextraction, and others, are reviewed. The review also summarizes the application of the columns produced with graphene-based materials in separating food and water components and contaminants. Graphene-based materials have been reported as stationary phases for LC columns. Graphene-based stationary phases have been reported in packed, monolithic, and open tubular columns and have been used in LC and capillary electrochromatography modes.
Collapse
Affiliation(s)
- João V B Borsatto
- Laboratory of Chromatography, Institute of Chemistry at Sao Carlos, University of Sao Paulo, P.O. Box 780, São Carlos 13566-590, Brazil
| | - Fernando M Lanças
- Laboratory of Chromatography, Institute of Chemistry at Sao Carlos, University of Sao Paulo, P.O. Box 780, São Carlos 13566-590, Brazil
| |
Collapse
|
3
|
Application of an in-house packed octadecylsilica-functionalized graphene oxide column for capillary liquid chromatography analysis of hormones in urine samples. Anal Chim Acta 2023; 1239:340718. [PMID: 36628720 DOI: 10.1016/j.aca.2022.340718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 12/07/2022] [Accepted: 12/09/2022] [Indexed: 12/14/2022]
Abstract
Graphene oxide-based LC stationary phases were developed and applied for separating hormones from urine using capillaryLC-MS/MS. Using two analytical approaches - direct injection and column-switching arrangement - it was possible to evaluate the chromatographic parameters and perform tests on the raw biological fluid. Two stationary phases (SPs) were produced, varying the amino silica support particle diameter (Si, 5, and 10 μm). Graphene oxide was covalently bonded to the surface of Si particles, and this material was functionalized by the insertion of octadecylsilica groups, generating the SiGO-C18. Infra-red spectroscopy assays revealed that both steps were successful - supporting GO onto Si and further C18 customization. Scanning electron microscopy showed spherical geometries with minor irregularities and narrow particle size distribution for the produced SPs. The GO-coating rate was higher on the Si particles of 10 μm. As a result, the 10 μm produced column reported better resolution, efficiency, and peak capacity. Therefore, this SiGO-C18 capillary column (100 mm × 0.32 mm i.d., 10 μm dp) was applied successfully in a column-switching method to separate hormones in urine. Linearity (R2 above 0.99), quantification limits (between 1.0 and 5 μg/L), and other figures of merit of the method were determined. It is worth mentioning that the SiGO-C18 capillaryLC column performed adequately, separating the target compounds in less than 6 min. We hope this work could significantly contribute to shedding some light on graphene-based materials as a promising class of stationary phase for miniaturized liquid chromatography.
Collapse
|
4
|
Zhou J, Wan M, Dai X, Yang H, Yang Y, Ou J, Liao M, Liu J, Wang L. Polar-embedded phenyl dendritic stationary phase for multi-mode chromatographic separation. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
5
|
Zhao C, Yan S, Liu J, Xiong Z, Zhao L. Octadecylamine and serine-derived carbon dots-modified silica gel for reversed phase/hydrophilic interaction liquid chromatography. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
6
|
Fu G, Gao C, Quan K, Li H, Qiu H, Chen J. Phosphorus-doped deep eutectic solvent-derived carbon dots-modified silica as a mixed-mode stationary phase for reversed-phase and hydrophilic interaction chromatography. Anal Bioanal Chem 2022:10.1007/s00216-022-04405-9. [PMID: 36350343 DOI: 10.1007/s00216-022-04405-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Revised: 10/20/2022] [Accepted: 10/25/2022] [Indexed: 11/10/2022]
Abstract
In this work, phosphorus-doped carbon dots (P-DESCDs) were successfully prepared using choline chloride/lactic acid type deep eutectic solvent and phosphoric acid as ingredients, and (3-aminopropyl) trimethoxysilane was used as a bridge to graft P-DESCDs onto the silica surface to obtain a new mixed-mode stationary phase (Sil-P-DESCDs) for reversed-phase and hydrophilic interaction liquid chromatography. The successful preparation of the stationary phase was confirmed by laser scanning confocal microscopy, elemental analysis, and Fourier transform infrared spectrometry. Interestingly, the doping of phosphorus greatly improved the separation performance and hydrophilicity of the Sil-P-DESCDs column. The Sil-P-DESCDs column was found to have certain hydrophobicity, hydrogen bonding ability and shape selectivity by Tanaka and Engelhardt standard test mixtures, and a series of hydrophilic and hydrophobic compounds such as alkylbenzenes, polycyclic aromatic hydrocarbons, sulfonamides, aromatic amines, phenols, flavonoids, nucleoside bases, and alkaloids. In addition, the effects of mobile phase ratio, column temperature, flow rate, salt concentration, and pH on the retention of analytes on Sil-P-DESCDs columns were investigated. Finally, the Sil-P-DESCDs column was applied to the qualitative and quantitative analysis of calcein-7-glucoside in the real sample of medicinal Astragalus pellets, and it was found at a concentration of 0.02 mg/mL.
Collapse
|
7
|
Ingenious introduction of aminopropylimidazole to tune the hydrophobic selectivity of dodecyl-bonded stationary phase for environmental organic pollutants. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
8
|
Quantitative evaluation of reversed-phase packing material based on calcium carbonate microspheres modified with an alternating copolymer. J Chromatogr A 2022; 1677:463294. [PMID: 35809518 DOI: 10.1016/j.chroma.2022.463294] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Revised: 06/27/2022] [Accepted: 06/28/2022] [Indexed: 11/24/2022]
Abstract
Considering the vulnerability of silica gel to alkaline mobile phases, a highly alkaline stable stationary phase for HPLC is required to separate basic compounds with high separation efficiency. To address this issue, we have developed a high alkaline stable packing material (CaCO3-PMAcO) based on mesoporous calcium carbonate microspheres modified with poly(maleic acid-alt-1-octadecene). In this study, we report further investigation of the separation performance of CaCO3-PMAcO column by systematically evaluating the effects of particle size and chromatographic conditions. Based on the theory of the van Deemter equation, the separation efficiency was related to the size of CaCO3-PMAcO particles (2.9 - 5.7 µm). The evaluation of thermodynamics of retention by changing the column temperature from 20 °C to 45 °C implied that the retention mode was dominated by hydrophobic interaction associated with the exothermic enthalpy changes (-11.1 to -12.5 kJ/mol). The results of column selectivity tests revealed that the CaCO3-PMAcO column had hydrophobic selectivity comparable to C18 silica gel columns (αP/B; CaCO3-PMAcO column: 1.53, C18 column: 1.69), and higher shape/steric selectivity (αTri/Ter; CaCO3-PMAcO column: 1.56, C18 column: 0.955). In practice, the CaCO3-PMAcO column could be applied to the separation of not only alkylbenzenes and polycyclic aromatic hydrocarbons, but also to basic tricyclic antidepressants by using an alkaline mobile phase (pH 12).
Collapse
|
9
|
Hybrid silica material as a mixed-mode sorbent for solid-phase extraction of hydrophobic and hydrophilic illegal additives from food samples. J Chromatogr A 2022; 1672:463049. [DOI: 10.1016/j.chroma.2022.463049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Revised: 04/08/2022] [Accepted: 04/08/2022] [Indexed: 11/17/2022]
|
10
|
Preparation and evaluation of an ionic liquid embedded C18 and cellulose co-functionalized stationary phase with mixed-mode and chiral separation abilities. Microchem J 2022. [DOI: 10.1016/j.microc.2021.107123] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
11
|
Zhong Z, Chu Z, Dong Z, Zhang W, Zhang L. The separation characteristics and performance evaluation of the silica-based poly(pentabromostyrene) stationary phase in capillary electrochromatography. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:5764-5771. [PMID: 34816827 DOI: 10.1039/d1ay01594j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
A mixed-mode capillary column packed with silica-based poly(pentabromostyrene) particles (denoted as SiO2@pPBS) was prepared and applied to capillary electrochromatography (CEC) separation. With the presence of benzene rings and bromine atoms in polymer chains, the SiO2@pPBS column provides a reversed-phase/hydrophilic mixed-mode retention mechanism owing to hydrophilic, hydrophobic and π-π interactions between the stationary phase and various analytes, including alkylbenzenes, polycyclic aromatic hydrocarbons, nucleosides, phenols and anilines. In CEC mode, the separation behavior of charged solutes is not only related to the interaction with the stationary phase, but also influenced by electrophoretic effects, which may lead to different selectivities compared to high performance liquid chromatography (HPLC). A column efficiency of up to 1.22 × 105 N m-1 was achieved for p-chloroaniline. Besides, the RSDs of retention time of anilines for run to run (n = 5), day to day (n = 5) and column to column (n = 3) were all less than 4.4%. Finally, the SiO2@pPBS capillary column was applied to the separation of coking wastewater with satisfactory results. All the results demonstrated that the SiO2@pPBS capillary packed column with RP/HILIC mixed-mode has great application potential.
Collapse
Affiliation(s)
- Zhihua Zhong
- Shanghai Key Laboratory of Functional Materials Chemistry, Department of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai 200237, China.
| | - Zhanying Chu
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, 100029, PR China
| | - Ziyi Dong
- Shanghai Key Laboratory of Functional Materials Chemistry, Department of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai 200237, China.
| | - Weibing Zhang
- Shanghai Key Laboratory of Functional Materials Chemistry, Department of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai 200237, China.
| | - Lingyi Zhang
- Shanghai Key Laboratory of Functional Materials Chemistry, Department of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai 200237, China.
| |
Collapse
|
12
|
Zheng Y, Wan M, Zhou J, Dai X, Yang H, Xia Z, Wang L. One-pot method for the synthesis of β-cyclodextrin and covalent organic framework functionalized chiral stationary phase with mixed-mode retention mechanism. J Chromatogr A 2021; 1662:462731. [PMID: 34915189 DOI: 10.1016/j.chroma.2021.462731] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2021] [Revised: 11/17/2021] [Accepted: 12/02/2021] [Indexed: 11/30/2022]
Abstract
As a welcomed porous material, covalent organic frameworks (COFs) have many advantages and are widely used in various aspects. Particularly, COFs have aroused great attentions of scientists in chromatographic separation field due to their outstanding advantages, such as high stability, large specific surface area and multiple voids. However, endowing COFs with chirality to construct chiral stationary phase (CSP) function is still facing many challenges. Here, we firstly prepared a β-cyclodextrin (β-CD) and covalent organic framework functional silica CSP named as COF@CD@SiO2 by one-pot method to perform high performance liquid chromatography (HPLC) chiral separation. The morphology and structure of the synthesized stationary phase were investigated by a variety of characterization methods including Fourier transform infrared spectrometry (FT-IR), thermogravimetric analysis (TGA), scanning electron microscopy (SEM), N2 adsorption experiment, powder X-ray diffraction (XRD) and elemental analysis (EA). The prepared stationary phase realized fast separation of six enantiomers in a short time. The separation mechanism was mainly ascribed to the inclusion complexation of β-cyclodextrin and the mutli-interaction sites from COFs material. In conclusion, the prepared chiral column can be used to achieve fast separation of enantiomers with good stability and reproducibility. These results can open new avenue for using chiral COFs in liquid chromatographic separation.
Collapse
Affiliation(s)
- Yunchao Zheng
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan 646000, China
| | - Meijun Wan
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan 646000, China
| | - Jingqiu Zhou
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan 646000, China
| | - Xuemei Dai
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan 646000, China
| | - Honglin Yang
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan 646000, China
| | - Zhining Xia
- School of Pharmacy, Chongqing University, Chongqing 401331, China.
| | - Lujun Wang
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan 646000, China; Key Laboratory of Medical Electrophysiology, Ministry of Education, Institute of Cardiovascular Research of Southwest Medical University, Luzhou, Sichuan 646000, China.
| |
Collapse
|
13
|
Fan C, Liu B, Li H, Quan K, Chen J, Qiu H. N-Vinyl pyrrolidone and undecylenic acid copolymerized on silica surface as mixed-mode stationary phases for reversed-phase and hydrophilic interaction chromatography. J Chromatogr A 2021; 1655:462534. [PMID: 34509123 DOI: 10.1016/j.chroma.2021.462534] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 08/26/2021] [Accepted: 08/30/2021] [Indexed: 12/11/2022]
Abstract
In this work, three new mixed-mode stationary phases were prepared, based on different ratio of N-vinyl pyrrolidone (NVP) copolymerized together with undecylenic acid (UA) on silica microspheres surface without silanization, which named Sil@NVPUA series. The combination of NVP and UA rendered the Sil@NVPUA suitable for reversed-phase liquid chromatography (RPLC) and hydrophilic interaction liquid chromatography (HILIC), and shown excellent methyl, planar, isomers and ion selectivity. Five types of model analytes including eight polycyclic aromatic hydrocarbons, six alkylbenzenes, eight nucleosides and nucleobases, seven ginsenosides and five oxazolidinones can be well separated on this stationary phase. The preparation method of NVP and UA modified silica-based stationary phase is simple, and it also provides a new idea for the design of synthetic polymers to develop mixed-mode chromatography.
Collapse
Affiliation(s)
- Chao Fan
- CAS Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Bei Liu
- CAS Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China
| | - Hui Li
- CAS Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China
| | - Kaijun Quan
- CAS Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China
| | - Jia Chen
- CAS Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China
| | - Hongdeng Qiu
- CAS Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China; University of Chinese Academy of Sciences, Beijing 100049, China; College of Chemistry, Zhengzhou University, Zhengzhou 450001, China.
| |
Collapse
|
14
|
Wang L, Pumera M. Covalently modified enzymatic 3D-printed bioelectrode. Mikrochim Acta 2021; 188:374. [PMID: 34628520 DOI: 10.1007/s00604-021-05006-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 08/25/2021] [Indexed: 10/20/2022]
Abstract
Three-dimensional (3D) printing has showed great potential for the construction of electrochemical sensor devices. However, reported 3D-printed biosensors are usually constructed by physical adsorption and needed immobilizing reagents on the surface of functional materials. To construct the 3D-printed biosensors, the simple modification of the 3D-printed device by non-expert is mandatory to take advantage of the remote, distributed 3D printing manufacturing. Here, a 3D-printed electrode was prepared by fused deposition modeling (FDM) 3D printing technique and activated by chemical and electrochemical methods. A glucose oxidase-based 3D-printed nanocarbon electrode was prepared by covalent linkage method to an enzyme on the surface of the 3D-printed electrode to enable biosensing. X-ray photoelectron spectroscopy and scanning electron microscopy were used to characterize the glucose oxidase-based biosensor. Direct electrochemistry glucose oxidase-based biosensor with higher stability was then chosen to detect the two biomarkers, hydrogen peroxide and glucose by chronoamperometry. The prepared glucose oxidase-based biosensor was further used for the detection of glucose in samples of apple cider. The covalently linked glucose oxidase 3D-printed nanocarbon electrode as a biosensor showed excellent stability. This work can open new doors for the covalent modification of 3D-printed electrodes in other electrochemistry fields such as biosensors, energy, and biocatalysis.
Collapse
Affiliation(s)
- Lujun Wang
- Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology (CEITEC-BUT), 61200, Brno, Czech Republic
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, 646000, People's Republic of China
- 3D Printing and Innovation Hub, Department of Food Technology, Mendel University in Brno, Zemedelska 1, CZ-613 00, Brno, Czech Republic
| | - Martin Pumera
- Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology (CEITEC-BUT), 61200, Brno, Czech Republic.
- 3D Printing and Innovation Hub, Department of Food Technology, Mendel University in Brno, Zemedelska 1, CZ-613 00, Brno, Czech Republic.
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seodaemungu, Seoul, 03722, South Korea.
- Department of Medical Research, China Medical University Hospital, China Medical University, No. 91 Hsueh-Shih Road, Taichung, Taiwan.
| |
Collapse
|
15
|
Li J, Sun Y, Liu L, Zhao H, Zhao W, He L, Zhang S. Fabrication and evaluation of tetraazahexaphenylmacrocycle-bonded stationary phase with multiple retention mechanisms. J Chromatogr A 2021; 1651:462296. [PMID: 34144400 DOI: 10.1016/j.chroma.2021.462296] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2021] [Revised: 05/22/2021] [Accepted: 05/25/2021] [Indexed: 11/17/2022]
Abstract
A 34-membered tetraazahexaphenylmacrocycle (N4Ph6) with a rigid π-conjugated moiety was chemically bonded to silica gel with 3-chloropropyltrimethoxysilane as the coupling agent to prepare a novel SiO2@N4Ph6 stationary phase. Several common organic analytes, including alkylbenzenes, polycyclic aromatic hydrocarbons, anilines, phenols, phthalates, and folic acid, were selected as probes to investigate its chromatographic performance. The as-developed SiO2@N4Ph6 stationary phase showed superiority retention and high selectivity for probe molecules through multiple interactions, including hydrophobic, π-π, hydrogen-bonding, and steric interactions. Density functional theory calculation results using folic acid as model solute provided an intuitive and a quantitative description of the multiple retention mechanisms.
Collapse
Affiliation(s)
- Junnan Li
- School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou 450001, China
| | - Yaming Sun
- School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou 450001, China; Key Laboratory of Accurate Separation and Analysis for Complex Matrix of Zhengzhou City, Zhengzhou 450001, China.
| | - Longhui Liu
- School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou 450001, China
| | - Hailiang Zhao
- School of Environmental Engineering, Henan University of Technology, Zhengzhou, 450001, China
| | - Wenjie Zhao
- School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou 450001, China; Key Laboratory of Accurate Separation and Analysis for Complex Matrix of Zhengzhou City, Zhengzhou 450001, China
| | - Lijun He
- School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou 450001, China; Key Laboratory of Accurate Separation and Analysis for Complex Matrix of Zhengzhou City, Zhengzhou 450001, China.
| | - Shusheng Zhang
- Center for Modern Analysis and Gene Sequencing, Zhengzhou University, Zhengzhou 450001, China
| |
Collapse
|
16
|
Zheng Y, Wan M, Zhou J, Luo Q, Gao D, Fu Q, Zeng J, Zu F, Wang L. Striped covalent organic frameworks modified stationary phase for mixed mode chromatography. J Chromatogr A 2021; 1649:462186. [PMID: 34034102 DOI: 10.1016/j.chroma.2021.462186] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Revised: 04/12/2021] [Accepted: 04/18/2021] [Indexed: 02/08/2023]
Abstract
Covalent organic frameworks (COFs) have showed expected potential in chromatographic separation due to unique structure and excellent performance. Nowadays, COF materials applied as chromatographic stationary phases is still in its infancy. Here, we modified COF materials on silica using benzene-1,4,5-tetracarboxylic dianhydride (PMDA) and 1,3,5-tris-(4-aminophenyl)triazine (TAPT) monomers by one-pot synthetic method for performing mixed-mode function, named as SiO2@COF. Five characterization methods including thermogravimetric analysis (TGA), scanning electron microscopy (SEM), Fourier transform infrared spectrometry (FT-IR), elemental analysis (EA) and powder X-ray diffraction (XRD) verified the morphology, structure characteristics and physicochemical properties of the materials. SiO2@COF for performing the separation of polar and nonpolar analytes on high performance liquid chromatography (HPLC) achieved the desired results. Retention mechanisms of the constructed SiO2@COF were researched via observing the effects of mobile phase with retention times. Results exhibited that the prepared stationary phase can provide various interaction modes, including hydrophobic, hydrophilic, hydrogen bonding and π-π interactions. In conclusion, the prepared SiO2@COF stationary phase can execute mixed-mode separation abilities and show potential for complex samples analysis.
Collapse
Affiliation(s)
- Yunchao Zheng
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan 646000, China
| | - Meijun Wan
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan 646000, China
| | - Jingqiu Zhou
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan 646000, China
| | - Qiurong Luo
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan 646000, China
| | - Die Gao
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan 646000, China
| | - Qifeng Fu
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan 646000, China
| | - Jing Zeng
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan 646000, China
| | - Fengjiao Zu
- School of Nursing, Southwest Medical University, Luzhou, Sichuan 646000, China
| | - Lujun Wang
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan 646000, China; Department of Pharmacy, The Affiliated Hospital of Southwes Medical University, Luzhou 646000, China,; Key Laboratory of Medical Electrophysiology, Ministry of Education, Institute of Cardiovascular Research of Southwest Medical University, Luzhou, Sichuan, 646000, China.
| |
Collapse
|