1
|
Melo LMA, de Faria LV, Arantes LC, Alves DAC, Rocha CM, de Fátima Â, Munoz RAA, Richter EM, T P Dos Santos W. An innovative approach for selective and robust screening of NBOHs, NBOMes, and LSD in forensic samples using a 3D-Printed electrochemical double cell. Talanta 2024; 276:126237. [PMID: 38776769 DOI: 10.1016/j.talanta.2024.126237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 05/07/2024] [Accepted: 05/09/2024] [Indexed: 05/25/2024]
Abstract
Lysergic acid diethylamide (LSD) and two phenethylamine classes (NBOHs and NBOMes) are the main illicit drugs found in seized blotter papers. The preliminary identification of these substances is of great interest for forensic analysis. In this context, this work constitutes the inaugural demonstration of an efficient methodology for the selective detection of LSD, NBOHs, and NBOMes, utilizing a fully 3D-printed electrochemical double cell (3D-EDC). This novel 3D-EDC enables the use of two working electrodes and/or two supporting electrolytes (at different pHs) in the same detection system, with the possibility of shared or individual auxiliary and pseudo-reference electrodes. Thus, the selective voltammetric detection of these substances is proposed using two elegant strategies: (i) utilizing the same 3D-EDC platform with two working electrodes (boron-doped diamond (BDD) and 3D-printed graphite), and (ii) employing two pH levels (4.0 and 12.0) with 3D-printed graphite electrode. This comprehensive framework facilitates a fast, robust, and uncomplicated electrochemical analysis. Moreover, this configuration enables a rapid and sensitive detection of LSD, NBOHs, and NBOMes in seized samples, and can also provide quantitative analysis. The proposed method showed good stability of the electrochemical response with RSD <9 % for Ip and <5 % for Ep, evaluating all oxidation processes observed for studied analytes (n = 7) at two pH levels, using the same and different (n = 3) working electrodes. It demonstrates a broad linear range (20-100 and 20-70 μmol L-1) and a low LOD (1.0 μmol L-1) for quantification of a model molecule (LSD) at the two pHs studied. Hence, the 3D-EDC combined with voltammetric techniques using BDD and 3D-printed graphite electrodes on the same platform, or only with this last sensor at two pH values, provide a practical and robust avenue for preliminary identification of NBOHs, NBOMes, and LSD. This method embodies ease, swiftness, cost-efficiency, robustness, and selectivity as an on-site screening tool for forensic analysis.
Collapse
Affiliation(s)
- Larissa M A Melo
- Departamento de Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil
| | - Lucas V de Faria
- Instituto de Química, Universidade Federal de Uberlândia, 38400-902, Uberlândia, Minas Gerais, Brazil; Instituto de Química, Universidade Federal Fluminense, 24020-141, Niterói, Rio de Janeiro, Brazil
| | - Luciano C Arantes
- Laboratório de Química e Física Forense, Instituto de Criminalística, Polícia Civil do Distrito Federal, 70610-907, Brasília, Distrito Federal, Brazil
| | - Diego A C Alves
- Faculdade de Engenharia Mecânica, Universidade Federal de Uberlândia, 38400-902, Uberlândia, Minas Gerais, Brazil
| | - Cláudia M Rocha
- Departamento de Química, Universidade Federal de Minas Gerais, 31270-901, Belo Horizonte, Minas Gerais, Brazil
| | - Ângelo de Fátima
- Departamento de Química, Universidade Federal de Minas Gerais, 31270-901, Belo Horizonte, Minas Gerais, Brazil
| | - Rodrigo A A Munoz
- Instituto de Química, Universidade Federal de Uberlândia, 38400-902, Uberlândia, Minas Gerais, Brazil
| | - Eduardo M Richter
- Instituto de Química, Universidade Federal de Uberlândia, 38400-902, Uberlândia, Minas Gerais, Brazil.
| | - Wallans T P Dos Santos
- Departamento de Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil; Departamento de Farmácia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil.
| |
Collapse
|
2
|
Lima CD, Magalhães de Almeida Melo L, Arantes LC, Conceição NDS, de França Schaffel I, Machado LL, de Queiroz Ferreira R, Pio Dos Santos WT. Simple and selective screening method for the synthetic cathinone MDPT in forensic samples using carbon nanofiber screen-printed electrodes. Talanta 2024; 269:125375. [PMID: 37977086 DOI: 10.1016/j.talanta.2023.125375] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 10/27/2023] [Accepted: 10/30/2023] [Indexed: 11/19/2023]
Abstract
3',4'-Methylenedioxy-N-tert-butylcathinone (MDPT), also known as tBuONE or D-Tertylone, is a synthetic cathinone (SC) frequently abused for recreational purposes due to its potent stimulant effects and similarity to illegal substances like methamphetamine and ecstasy. The structural diversity and rapid introduction of new SC analogs to the market poses significant challenges for law enforcement and analytical methods for preliminary screening of illicit drugs. In this work, we present, for the first time, the electrochemical detection of MDPT using screen-printed electrodes modified with carbon nanofibers (SPE-CNF). MDPT exhibited three electrochemical processes (two oxidations and one reduction) on SPE-CNF. The proposed method for MDPT detection was optimized in 0.2 mol L-1 Britton-Robinson buffer solution at pH 10.0 using differential pulse voltammetry (DPV). The SPE-CNF showed a high stability for electrochemical responses of all redox processes of MDPT using the same or different electrodes, with relative standard deviations less than 4.7% and 1.5% (N = 3) for peak currents and peak potentials, respectively. Moreover, the proposed method provided a wide linear range for MDPT determination (0.90-112 μmol L-1) with low LOD (0.26 μmol L-1). Interference studies for two common adulterants, caffeine and paracetamol, and ten other illicit drugs, including amphetamine-like compounds and different SCs, showed that the proposed sensor is highly selective for the preliminarily identification of MDPT in seized forensic samples. Therefore, SPE-CNF with DPV can be successfully applied as a fast and simple screening method for MDPT identification in forensic analysis, addressing the significant challenges posed by the structural diversity of SCs.
Collapse
Affiliation(s)
- Camila Diana Lima
- Departamento de Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil
| | - Larissa Magalhães de Almeida Melo
- Departamento de Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil
| | - Luciano Chaves Arantes
- Laboratório de Química e Física Forense, Instituto de Criminalística, Polícia Civil do Distrito Federal, 70610-907, Brasília, Distrito Federal, Brazil
| | - Nathália Dos Santos Conceição
- Departamento de Química, Universidade Federal do Espírito Santo, Campus Goiabeiras, 29075910, Vitória, Espírito Santo, Brazil
| | - Izabela de França Schaffel
- Departamento de Química, Universidade Federal do Espírito Santo, Campus Goiabeiras, 29075910, Vitória, Espírito Santo, Brazil
| | - Lara Lima Machado
- Departamento de Farmácia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil
| | - Rafael de Queiroz Ferreira
- Departamento de Química, Universidade Federal do Espírito Santo, Campus Goiabeiras, 29075910, Vitória, Espírito Santo, Brazil
| | - Wallans Torres Pio Dos Santos
- Departamento de Farmácia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil.
| |
Collapse
|
3
|
Rosendo LM, Antunes M, Simão AY, Brinca AT, Catarro G, Pelixo R, Martinho J, Pires B, Soares S, Cascalheira JF, Passarinha L, Rosado T, Barroso M, Gallardo E. Sensors in the Detection of Abused Substances in Forensic Contexts: A Comprehensive Review. MICROMACHINES 2023; 14:2249. [PMID: 38138418 PMCID: PMC10745465 DOI: 10.3390/mi14122249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2023] [Revised: 12/10/2023] [Accepted: 12/13/2023] [Indexed: 12/24/2023]
Abstract
Forensic toxicology plays a pivotal role in elucidating the presence of drugs of abuse in both biological and solid samples, thereby aiding criminal investigations and public health initiatives. This review article explores the significance of sensor technologies in this field, focusing on diverse applications and their impact on the determination of drug abuse markers. This manuscript intends to review the transformative role of portable sensor technologies in detecting drugs of abuse in various samples. They offer precise, efficient, and real-time detection capabilities in both biological samples and solid substances. These sensors have become indispensable tools, with particular applications in various scenarios, including traffic stops, crime scenes, and workplace drug testing. The integration of portable sensor technologies in forensic toxicology is a remarkable advancement in the field. It has not only improved the speed and accuracy of drug abuse detection but has also extended the reach of forensic toxicology, making it more accessible and versatile. These advancements continue to shape forensic toxicology, ensuring swift, precise, and reliable results in criminal investigations and public health endeavours.
Collapse
Affiliation(s)
- Luana M. Rosendo
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
| | - Mónica Antunes
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
| | - Ana Y. Simão
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
| | - Ana Teresa Brinca
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
| | - Gonçalo Catarro
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
| | - Rodrigo Pelixo
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
| | - João Martinho
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
| | - Bruno Pires
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
| | - Sofia Soares
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
| | - José Francisco Cascalheira
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Departamento de Química, Universidade da Beira Interior, 6200-001 Covilhã, Portugal
| | - Luís Passarinha
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
- Associate Laboratory i4HB-Institute for Health and Bioeconomy, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 2819-516 Caparica, Portugal
- UCIBIO-Applied Molecular Biosciences Unit, Chemistry Department, NOVA School of Science and Technology, 2829-516 Caparica, Portugal
| | - Tiago Rosado
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
- Centro Académico Clínico das Beiras (CACB)—Grupo de Problemas Relacionados com Toxicofilias, 6200-000 Covilhã, Portugal
| | - Mário Barroso
- Serviço de Química e Toxicologia Forenses, Instituto de Medicina Legal e Ciências Forenses—Delegação do Sul, 1169-201 Lisboa, Portugal
| | - Eugenia Gallardo
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
- Centro Académico Clínico das Beiras (CACB)—Grupo de Problemas Relacionados com Toxicofilias, 6200-000 Covilhã, Portugal
| |
Collapse
|
4
|
Macedo AA, Arantes LC, Pimentel DM, de Deus Melo T, Magalhães de Almeida Melo L, Alves de Barros W, Rocha CM, de Fátima Â, Pio Dos Santos WT. Comprehensive detection of lysergic acid diethylamide (LSD) in forensic samples using carbon nanotube screen-printed electrodes. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:5837-5845. [PMID: 37874181 DOI: 10.1039/d3ay01385e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2023]
Abstract
Lysergic acid diethylamide (LSD) is a prevalent psychoactive substance recognized for its hallucinogenic properties, often encountered in blotter papers for illicit consumption. Given that LSD ranks among the most widely abused illicit drugs globally, its prompt identification in seized samples is vital for forensic investigations. This study presents, for the first time, an electrochemical screening method for detecting LSD in forensic samples, utilizing a multi-wall carbon nanotube screen-printed electrode (SPE-MWCNT). The LSD detection process was optimized on SPE-MWCNT in a phosphate buffer solution (0.1 mol L-1, pH 12.0) using square wave voltammetry (SWV). The combined use of SPE-MWCNT with SWV displayed robust stability in electrochemical responses for both qualitative (peak potential) and quantitative (peak current) LSD assessment, with a relative standard deviation (RSD) of less than 5% across the same or different electrodes (N = 3). A linear detection range was established between 0.16 and 40.0 μmol L-1 (R2 = 0.998), featuring a low limit of detection (LOD) of 0.05 μmol L-1. Interference studies with twenty-three other substances, including groups of phenethylamines typically found in blotting papers (e.g., NBOHs and NBOMes) and traditional illicit drugs, were performed, revealing a highly selective response for LSD using the proposed method. Consequently, the integration of SPE-MWCNT with SWV offers a robust tool for qualitative and quantitative LSD analysis in forensic applications, providing rapid, sensitive, selective, reproducible, and straightforward preliminary identification in seized samples.
Collapse
Affiliation(s)
- Anne Alves Macedo
- Departamento de Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, Diamantina, 39100000, Minas Gerais, Brazil.
| | - Luciano C Arantes
- Laboratório de Química e Física Forense, Instituto de Criminalística, Polícia Civil do Distrito Federal, 70610-907, Brasília, Distrito Federal, Brazil
| | - Dilton Martins Pimentel
- Laboratório Integrado de Pesquisas do Vale do Jequitinhonha, Pró-Reitoria de Pesquisa e Pós-Graduação, Universidade Federal dos Vales do Jequitinhonha e Mucuri, CampusJK, 39100000 Diamantina, Minas Gerais, Brazil
| | - Tifany de Deus Melo
- Departamento de Farmácia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil
| | - Larissa Magalhães de Almeida Melo
- Departamento de Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, Diamantina, 39100000, Minas Gerais, Brazil.
| | - Wellington Alves de Barros
- Departamento de Química, Instituto de Ciências Exatas, Universidade Federal de Minas Gerais, 31270-901, Belo Horizonte, Minas Gerais, Brazil
| | - Cláudia Mancilha Rocha
- Departamento de Química, Instituto de Ciências Exatas, Universidade Federal de Minas Gerais, 31270-901, Belo Horizonte, Minas Gerais, Brazil
| | - Ângelo de Fátima
- Departamento de Química, Instituto de Ciências Exatas, Universidade Federal de Minas Gerais, 31270-901, Belo Horizonte, Minas Gerais, Brazil
| | - Wallans Torres Pio Dos Santos
- Departamento de Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, Diamantina, 39100000, Minas Gerais, Brazil.
- Laboratório Integrado de Pesquisas do Vale do Jequitinhonha, Pró-Reitoria de Pesquisa e Pós-Graduação, Universidade Federal dos Vales do Jequitinhonha e Mucuri, CampusJK, 39100000 Diamantina, Minas Gerais, Brazil
| |
Collapse
|
5
|
Melo LMA, Arantes LC, Schaffel IF, Aranha LMS, Conceição NS, Lima CD, Marinho PA, Ferreira RQ, Dos Santos WTP. Electrochemical detection of mephedrone using a graphene screen-printed electrode: a new sensitive and selective approach to identify synthetic cathinones in forensic analysis. Analyst 2023; 148:1552-1561. [PMID: 36880972 DOI: 10.1039/d3an00065f] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
Abstract
Mephedrone (MEP) is an illicit stimulant drug that belongs to the synthetic cathinone (SC) class, which has been widely used for recreational purposes and reported in forensic analysis. The preliminary identification of MEP and other SCs in seized samples is of great interest for forensic investigation and a fast and simple screening test for these drugs would be useful for on-site and in-house analyses. In this study, we present the electrochemical detection of MEP in forensic samples using, for the first time, independent redox processes of SCs on a graphene screen-printed electrode (SPE-GP). The proposed method for MEP detection on the SPE-GP was optimized in Britton-Robinson buffer solution (0.1 mol L-1) at pH 10.0 with adsorptive stripping differential pulse voltammetry (AdSDPV). The use of the SPE-GP with AdSDPV provides a wide linear range for MEP determination (2.6 to 112 μmol L-1) with a low limit of detection (LOD) (0.3 μmol L-1). The real surface area available for adsorption on the SPE-GP was estimated to be between 3.80 and 5.70 cm2, which provided high sensitivity for the proposed method. Furthermore, good stability of MEP electrochemical responses on the SPE-GP was obtained using the same or different electrodes (N = 3), with relative standard deviation (RSD) < 5.0% for both redox processes. Interference studies for a common adulterant (caffeine) and twelve other illicit drugs (phenethylamines, amphetamines, and other SCs) were performed with a highly selective response for MEP detection. Therefore, the SPE-GP with AdSDPV is demonstrated to be a selective and sensitive screening method to detect MEP and other SCs in forensic analysis, providing a fast and simple preliminary identification of these drugs in seized samples.
Collapse
Affiliation(s)
- Larissa M A Melo
- Departamento de Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil.
| | - Luciano C Arantes
- Laboratório de Química e Física Forense, Instituto de Criminalística, Polícia Civil do Distrito Federal, 70610-907, Brasília, Distrito Federal, Brazil
| | - Izabela F Schaffel
- Departamento de Química, Universidade Federal do Espírito Santo, Campus Goiabeiras, 29075910, Vitória, Espírito Santo, Brazil
| | - Lívia M S Aranha
- Departamento de Farmácia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil
| | - Nathália S Conceição
- Departamento de Química, Universidade Federal do Espírito Santo, Campus Goiabeiras, 29075910, Vitória, Espírito Santo, Brazil
| | - Camila D Lima
- Departamento de Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil.
| | - Pablo A Marinho
- Instituto de Criminalística, Polícia Civil de Minas Gerais, 30180-060, Belo Horizonte, Minas Gerais, Brazil
| | - Rafael Q Ferreira
- Departamento de Química, Universidade Federal do Espírito Santo, Campus Goiabeiras, 29075910, Vitória, Espírito Santo, Brazil
| | - Wallans T P Dos Santos
- Departamento de Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil. .,Departamento de Farmácia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil
| |
Collapse
|
6
|
Lugo Vargas AF, Quevedo Buitrago WG, Chaves Silva DC, Martínes Suárez JF. Voltammetric Responses of a CYP2D6‐Based Biosensor to 3,4‐methylenedioxymethamphetamine (MDMA) and the Synthetic Cathinone α‐pyrrolidinopentiophenone (α‐PVP). ChemistrySelect 2022. [DOI: 10.1002/slct.202202748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
7
|
Paraformaldehyde-coated electrochemical sensor for improved on-site detection of amphetamine in street samples. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107518] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|